0% found this document useful (0 votes)
13 views2 pages

Emission Calculation

The document outlines the task of estimating annual emissions for a textile manufacturing facility, ABC, in Algenia for the year 2022. It provides detailed information on energy consumption, fuel usage, and emission factors necessary for calculating Scope 1 and Scope 2 emissions. The calculations will include emissions from electricity, boiler fuels, transport vehicles, cooking, and refrigerants.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views2 pages

Emission Calculation

The document outlines the task of estimating annual emissions for a textile manufacturing facility, ABC, in Algenia for the year 2022. It provides detailed information on energy consumption, fuel usage, and emission factors necessary for calculating Scope 1 and Scope 2 emissions. The calculations will include emissions from electricity, boiler fuels, transport vehicles, cooking, and refrigerants.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Quiz

ABC is a textile manufacturing facility located in a country called Algenia. Assume you are the
sustainability person at the facility and, you are given the task to estimate their annual emissions
for 2022.
During the year 2022, ABC consumed 6,000,000.00 kWh of electricity. They used a diesel
generator for backup electricity which they used 15,000 litres. The facility also uses a boiler to
generate steam which they have two types of fuels.
Biomass quantity of 12,500 MTs, and 245,000 liters of furnace oil
The facility also owns a transport truck has used up 125,000 litres of petrol (Gasoline) during the
year. The facility kitchen is owned by the company itself and has used 1450 kg of LPG for cooking
purpose. A weight of 25 kg of R22 refrigerant has used for the air conditioning systems.
Do the calculations in MT CO2e
1. Grid Electricity Emission for ABC company in 2022 in Tons
2. Emissions from the boiler in Tons
3. Emissions from own vehicles in Tons
4. Emission from fugitive sources
5. Emission generated through cooking purposes
6. Total Scope 1 Emissions
7. Total Scope 2 Emission

Use following sample factors for calculations

GWP
CO2 CH4 N2O
1 28 265

Stationary Combustion Emission Factors (sample)


Fuel Unit Factor Per Unit
CO2 CH4 N2O
Diesel L 2.676 0.0003612 0.0000217
Petrol L 2.271 0.0003278 0.0000197
Kerosene L 2.519 0.0003504 0.0000210
Furnace Oil L 2.939 0.0003798 0.0000228
LPG
Combustion Kg 2.984 0.0002365 0.0000047
Biomass Kg 1.747 0.0046800 0.0000624

Mobile Combustion Emission Factors (sample)


Fuel Unit Factor Per Unit
CO2 CH4 N2O
Diesel L 2.676 0.0001409 0.0001409
Petrol L 2.272 0.0010818 0.0001050

© Rishan Sampath-2023
Refrigerant GWP
R22 1760
R134A 1300
R410A 1924

Country GEF (kg/kWh)


2020 2021
Algenia 0.5545 0.5425

© Rishan Sampath-2023

You might also like