Datasheet 593336 (98-8010) en 120V 60Hz
Datasheet 593336 (98-8010) en 120V 60Hz
8010
LabVolt Series
Datasheet
Festo Didactic
en 120 V - 60 Hz
* The product images shown in this document are for illustration purposes; actual products may vary. Please refer to the Specifications section of
each product/item for all details. Festo Didactic reserves the right to change product images and specifications at any time without notice. 02/2023
Electric Power Technology Training Systems, LabVolt Series
Table of Contents
General Description_________________________________________________________________________________ 4
Electric Power Technology Training Program ____________________________________________________________ 4
Electric Power Technology Training Systems ____________________________________________________________ 5
Custom Training Solutions ___________________________________________________________________________ 8
Course Description _________________________________________________________________________________ 9
DC Power Circuits (86350) __________________________________________________________________________ 10
Lead-Acid Batteries (86351)_________________________________________________________________________ 10
Ni-MH Batteries (86354)____________________________________________________________________________ 11
Solar Power (86352) _______________________________________________________________________________ 12
Introduction to Wind Power (86353) __________________________________________________________________ 13
Permanent Magnet DC Motor (86357)_________________________________________________________________ 13
Hydrogen Fuel Cell (86355) _________________________________________________________________________ 14
DC Power Electronics (86356) _______________________________________________________________________ 15
DC Motor Drives (88553) ___________________________________________________________________________ 16
Single-Phase AC Power Circuits (86358)_______________________________________________________________ 17
Single-Phase Power Transformers (86377) ____________________________________________________________ 18
Conventional DC Machines and Universal Motor (88943)_________________________________________________ 19
Single-Phase AC Power Electronics (86359)____________________________________________________________ 20
High-Frequency Power Transformers (86378) __________________________________________________________ 21
Home Energy Production (86361) ____________________________________________________________________ 22
Three-Phase AC Power Circuits (86360) _______________________________________________________________ 23
Three-Phase Rotating Machines (86364) ______________________________________________________________ 24
Power Factor Correction (20116) _____________________________________________________________________ 25
Single-Phase Induction Motors (88944) _______________________________________________________________ 26
Three-Phase Wound-Rotor Induction Machine (86367) __________________________________________________ 27
Three-Phase Transformer Banks (86379) ______________________________________________________________ 27
AC Transmission Lines (20521) ______________________________________________________________________ 28
Basic Controls (87774) _____________________________________________________________________________ 29
Motor Drives (87668) ______________________________________________________________________________ 30
Programmable Logic Controller (39436) _______________________________________________________________ 31
Sensors (39654) __________________________________________________________________________________ 32
Three-Phase AC Power Electronics (86362) ____________________________________________________________ 33
Thyristor Power Electronics (86363) __________________________________________________________________ 34
Hydropower Electricity Generation (86369) ____________________________________________________________ 35
Three-Phase Induction Motor Starters (88197) _________________________________________________________ 36
Three-Phase Motor Drives (86368) ___________________________________________________________________ 37
Principles of Doubly-Fed Induction Generators (86376) __________________________________________________ 38
Three-Phase PWM Rectifier/Inverter (86366) __________________________________________________________ 39
BLDC Motors and Vector Control PMSM Drives (86373) __________________________________________________ 40
High-Voltage DC Transmission Systems (86380)________________________________________________________ 41
Static Var Compensator (86370) _____________________________________________________________________ 42
Static Synchronous Compensator (STATCOM) (86371) ___________________________________________________ 43
Introduction to Electric Power Substations (20528) _____________________________________________________ 44
Overcurrent and Overload Protection Using Protective Relays (52173) _____________________________________ 45
Directional Protection (52174) ______________________________________________________________________ 46
List of Available Training Systems____________________________________________________________________ 46
© Festo Didactic 2
Electric Power Technology Training Systems, LabVolt Series
3 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
General Description
The production of energy using renewable natural resources such as wind, sunlight, rain, tides, geothermal
heat, etc., has gained much importance in recent years as it is an effective means of reducing greenhouse gas
(GHG) emissions. The need for innovative technologies to make the grid smarter has recently emerged as a
major trend as the increase in electrical power demand observed worldwide makes it harder for the actual grid
in many countries to keep up with demand. Furthermore, electric vehicles, from bicycles to cars, are developed
and marketed with more and more success in many countries all over the world.
The Electric Power Technology Training Program was developed to answer the increasingly diversified needs for
training in the wide field of electrical energy. It is a modular study program for technical institutes, colleges, and
universities.
The program starts with a variety of courses providing in-depth coverage of basic topics related to the field of
electrical energy such as ac and dc power circuits, power transformers, rotating machines, ac power
transmission lines, industrial controls, and power electronics. These basic courses incorporate most of the
subject matter covered in other well established training systems such as the Electromechanical Training
System, Model 8006, Power Electronics Training System, Model 8032, Industrial Controls Training Systems,
Series 8036, and Power Transmission Training System, Model 8055, as well as many new topics related to
recent technologies.
The program then builds on the knowledge gained by the student through these basic courses to provide
training in more advanced subjects such as home energy production from renewable resources (wind and
sunlight), large-scale electricity production from hydropower, large-scale electricity production from wind power
(doubly-fed induction generator [DFIG], synchronous generator, and asynchronous generator technologies),
smart-grid technologies (SVC, STATCOM, HVDC transmission, etc.), storage of electrical energy in batteries, and
drive systems for small electric vehicles and cars.
The Electric Power Technology Training Systems, Series 8010, are based on the Electric Power Technology
Training Program, each system providing a turn-key solution dealing with some aspects of the wide field of
electrical energy. Each system is based on a proven modular design approach. Also, most systems use
computer-based data acquisition and control to provide unrivaled training in electrical energy. For this purpose,
the Four-Quadrant Dynamometer/Power Supply, Model 8960, and the Data Acquisition and Control Interface,
Model 9063, were developed. These modules are powerful USB peripherals that greatly enhance the learning
experience of students.
The Electric Power Technology Training Program being highly modular, both hardware and courseware wise, it
allows courses to be selected (topic coverage) in order to build a training solution matching specific needs.
© Festo Didactic 4
Electric Power Technology Training Systems, LabVolt Series
Other training systems will be created as additional courses in the Electric Power Technology Training Program
become available. Each training system is a turn-key solution that includes the equipment and courseware
material required to perform a different combination of courses in the Electric Power Technology Training
Program (see table on the next two pages) focusing on specific aspects related to the wide field of electrical
energy. Each system uses the Four-Quadrant Dynamometer/Power Supply, Model 8960, and/or the Data
Acquisition and Control Interface, Model 9063, two powerful USB peripherals that greatly enhance hands-on
learning. Refer to the Lists of Equipment section of this data sheet for the list of equipment included in each
training system.
The Data Acquisition and Control Interface, Model 9063, is a highly versatile
USB peripheral used for measuring, observing, analyzing, and controlling
electrical parameters in electric power systems and power electronics circuits.
© Festo Didactic 6
Electric Power Technology Training Systems, LabVolt Series
The following table indicates the combination of courses which can be performed with each Electric Power
Technology Training System. Black dots in the table indicate the courses that can be performed with each
training system. Red dots indicate popular complementary courses that can optionally be added to a training
system.
If none of these Electric Power Technology Training Systems meets your specific training needs, please refer to
the Custom Training Solutions section of this data sheet to learn how a training solution can be adapted to your
needs.
7 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
© Festo• Didactic
DC Power Circuits (86350) 8
Course Description
The Electric Power Technology Training Program consists of a wide selection of courses which are listed below.
• DC Power Circuits
• Lead-Acid Batteries
• Ni-MH Batteries
• Solar Power (photovoltaic)
• Introduction to Wind Power
• Permanent Magnet DC Motor
• Hydrogen Fuel Cell
• DC Power Electronics
• DC Motor Drives
• Single-Phase AC Power Circuits
• Single-Phase Power Transformers
• Conventional DC Machines and Universal Motor
• Single-Phase AC Power Electronics
• High-Frequency Power Transformers
• Home Energy Production
• Three-Phase AC Power Circuits
• Three-Phase Rotating Machines
9 • Power Factor Correction © Festo Didactic
• Single-Phase Induction Motors
• Three-Phase Wound-Rotor Induction Machine
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• None
• Battery Fundamentals
• Discharge Characteristics
• Battery Charging Fundamentals
• Battery Charging Methods
Prerequisites
• DC Power Circuits
© Festo Didactic 10
Electric Power Technology Training Systems, LabVolt Series
• Battery Fundamentals
• Battery Capacity Versus Discharge Rate
• Battery Charging Fundamentals
• Battery Charging Methods
Prerequisites
• DC Power Circuits
11 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
• The Diode
• The Solar Panel (Photovoltaic Panel)
• Effect of Temperature on Solar Panel Performance
• Storing Energy from Solar Panels into Batteries
• Effect of Shading on Solar Panel Operation
• Solar Panel Orientation (optional)
• Solar Panel Performance versus Insolation (optional)
Prerequisites
• DC Power Circuits
© Festo Didactic 12
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
Prerequisites
• DC Power Circuits
13 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
© Festo Didactic 14
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
15 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• Permanent Magnet DC Motor
• DC Power Electronics
© Festo Didactic 16
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
17 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
© Festo Didactic 18
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
19 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• DC Power Electronics
• Single-Phase AC Power Circuits
© Festo Didactic 20
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
• Single-Phase Power Transformers
21 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• Lead-Acid Batteries
• Solar Power (photovoltaic)
• Introduction to Wind Power
• DC Power Electronics
• Single-Phase AC Power Circuits
• Single-Phase AC Power Electronics
• Single-Phase Power Transformers
• High-Frequency Power Transformers
© Festo Didactic 22
Electric Power Technology Training Systems, LabVolt Series
• Three-Phase Circuits
• Three-Phase Power Measurement
• Phase Sequence
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
23 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
• Three-Phase AC Power Circuits
© Festo Didactic 24
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
• Three-Phase AC Power Circuits
• Three-Phase Rotating Machines
25 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
• Three-Phase AC Power Circuits
• Three-Phase Rotating Machines
© Festo Didactic 26
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
• Three-Phase AC Power Circuits
• Three-Phase Rotating Machines
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
• Single-Phase Power Transformers
• Three-Phase AC Power Circuits
27 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
• Single-Phase Power Transformers
• Three-Phase AC Power Circuits
• Three-Phase Transformer Banks
© Festo Didactic 28
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
• Single-Phase Power Transformers
• Three-Phase AC Power Circuits
29 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
• AC Drives
• DC Drives
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
• Single-Phase Power Transformers
• Three-Phase AC Power Circuits
• Basic Controls
© Festo Didactic 30
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
• Single-Phase Power Transformers
• Three-Phase AC Power Circuits
• Basic Controls
31 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Sensors (39654)
The Sensors course introduces
students to sensors and to the terms
commonly used in the sensor field. It
covers the operation of a wide variety
of switches, such as background
suppression switches, polarized
retroreflective photoelectric switches,
capacitive proximity switches,
inductive proximity switches, and limit
switches. Two optional exercises
familiarize students with the use of
sensors and a limit switch in motor-
operated circuits, as well as with the design of circuits using sensors, a PLC, and a motor based on project
descriptions.
Topic Coverage (8 exercise)
• Introduction to sensors
• Background Suppression Photoelectric Switch
• Polarized Retroreflective Photoelectric Switch
• Capacitive Proximity Switch
• Inductive Proximity Switch
• Limit Switch
• Motor-Operated Circuits Using Sensors (optional)
• PLC-Controlled Circuits Using Sensors (optional)
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
• Single-Phase Power Transformers
• Three-Phase AC Power Circuits
• Basic Controls
© Festo Didactic 32
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• DC Power Electronics
• Single-Phase AC Power Circuits
• Single-Phase AC Power Electronics
• Three-Phase AC Power Circuits
33 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
• Three-Phase AC Power Circuits
© Festo Didactic 34
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
• Three-Phase AC Power Circuits
• Thyristor Power Electronics
• Three-Phase Rotating Machines
35 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
• Motor Starters
• Advanced Soft Starters Features
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
• Three-Phase AC Power Circuits
• Thyristor Power Electronics
• Three-Phase Rotating Machines
© Festo Didactic 36
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• DC Power Electronics
• Single-Phase AC Power Circuits
• Single-Phase AC Power Electronics
• Three-Phase AC Power Circuits
• Three-Phase AC Power Electronics
• Three-Phase Rotating Machines
37 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• DC Power Electronics
• Single-Phase AC Power Circuits
• Single-Phase AC Power Electronics
• Three-Phase AC Power Circuits
• Three-Phase AC Power Electronics
• Three-Phase Rotating Machines
• Three-Phase Motor Drives
• Three-Phase Wound-Rotor Induction Machine
© Festo Didactic 38
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• DC Power Electronics
• Lead-Acid Batteries
• Solar Power (photovoltaic)
• Introduction to Wind Power
• Single-Phase AC Power Circuits
• Single-Phase AC Power Electronics
• Single-Phase Power Transformers
• Three-Phase AC Power Circuits
• Three-Phase AC Power Electronics
• High-Frequency Power Transformer
• Home Energy Production
39 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• Lead-Acid Batteries
• Solar Power (photovoltaic)
• Introduction to Wind Power
• DC Power Electronics
• Single-Phase AC Power Circuits
• Single-Phase AC Power Electronics
• Single-Phase Power Transformers
• Three-Phase AC Power Circuits
• High-Frequency Power Transformers
• Three-Phase AC Power Electronics
• Three-Phase Rotating Machines
• Home Energy Production
• Three-Phase PWM Rectifier/Inverter
• Three-Phase Motor Drives
© Festo Didactic 40
Electric Power Technology Training Systems, LabVolt Series
• Voltage Regulation and Displacement Power Factor (DPF) in Thyristor Three-Phase Bridges
• Basic Operation of HVDC Transmission Systems
• DC Current Regulation and Power Flow Control in HVDC Transmission Systems
• Commutation Failure at the Inverter Bridge
• Harmonic Reduction using Thyristor 12-Pulse Converters
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
• Single-Phase Power Transformers
• Three-Phase AC Power Circuits
• Thyristor Power Electronics
• Three-Phase Transformer Banks
• AC Transmission Lines
41 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
• Single-Phase Power Transformers
• Three-Phase AC Power Circuits
• Thyristor Power Electronics
• Three-Phase Transformer Banks
• AC Transmission Lines
© Festo Didactic 42
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• Lead-Acid Batteries
• Solar Power (photovoltaic)
• Introduction to Wind Power
• DC Power Electronics
• Single-Phase AC Power Circuits
• Single-Phase AC Power Electronics
• Single-Phase Power Transformers
• High-Frequency Power Transformers
• Three-Phase AC Power Circuits
• Three-Phase Transformer Banks
• Home Energy Production
• Three-Phase PWM Rectifier/Inverter
• AC Transmission Lines
43 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
• Single-Phase Power Transformers
• Three-Phase AC Power Circuits
• Three-Phase Transformer Banks
© Festo Didactic 44
Electric Power Technology Training Systems, LabVolt Series
• Overcurrent Protection
• Overcurrent and Overload Protection of AC Machines and Power Transformers
• Overcurrent Protection of Radial Feeders
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
• Single-Phase Power Transformers
• Three-Phase AC Power Circuits
• Three-Phase Transformer Banks
45 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Prerequisites
• DC Power Circuits
• Single-Phase AC Power Circuits
• Single-Phase Power Transformers
• Three-Phase AC Power Circuits
• Three-Phase Transformer Banks
• Overcurrent and Overload Protection Using Protective Relays
© Festo Didactic 46
Electric Power Technology Training Systems, LabVolt Series
Model
Qty Description
number
1 Hydrogen Fuel Cell Training System _________________________________________________ 579307 (801080)
1 Electromechanical Training System _________________________________________________ 579308 (801090)
1 Power Electronics Training System __________________________________________________ 579314 (8010A0)
1 AC Power Transmission Training System _____________________________________________ 579320 (8010B0)
1 Smart Grid Technologies Training System ____________________________________________ 579325 (8010C0)
1 DFIG Principles Training System ____________________________________________________ 579328 (8010D0)
1 Power Transmission Smart Grid Technologies Training System ____________________________ 579331 (8010E0)
1 Smart Grid Training System _______________________________________________________ 8117310 (8010F0)
1 Hydropower Electricity Generation Training System ___________________________________ 8108668 (8010G0)
1 BLDC Motors and Vector Control PMSM Drives Training System __________________________ 8108674 (8010J0)
1 Electric Power Substations Training System _________________________________________ 8108677 (8010K0)
1 Numerical Protective Relays Training System _________________________________________ 8108680 (8010L0)
Optional Equipment
Model
Qty Description
number
1 Electric Power Technology Training Systems (Manuals on CD-ROM) ______________________ 580543 (86350A0)
47 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
The above chart shows all courses in the Electric Power Technology Training Program. Blue boxes highlight courses included in the
training system covered in this datasheet, while dark grey boxes, if any, highlight courses that can be optionally added to this
training system.
Courseware
Each course in the training system includes a full-color student manual providing all the theoretical matter
required, guided lab-exercise procedures to be performed with the training equipment, and review questions
that test the knowledge gained by the student. Whenever possible, each course is built to bring the student to
actual applications as soon as possible. A full-color instructor guide providing all lab results and answers to
questions is also included with each course.
© Festo Didactic 48
Electric Power Technology Training Systems, LabVolt Series
Modular Approach
The modular approach for designing the training program and lab equipment enables instructors to start
building their electrical-energy laboratory with a basic package of courses and equipment and add new courses
and equipment over time without needless duplication of equipment.
All lab equipment consists of modules that can be inserted into a workstation. Module dimensions vary
between two standard EMS sizes: full-size and half-size. Symbols and diagrams representing the electrical
components in each module are clearly silk-screened on the front panel. Standard, color-coded safety banana
jacks are used to provide access to the various components in each module.
elearning Formats
The courseware is also available in three eLearning formats for users preferring a computer-based approach:
Please refer to our website at www.labvolt.com for more information about the Mind-Sight, SCORM, and Stand-
Alone eLearning formats.
• The training system teaches simply and effectively the basic principles of electrical power for both
direct current (dc) and alternating current (ac).
• The course curriculum of the Electric Power Technology Training Program is highly flexible and allows a
multitude of different customized training solutions.
• The courseware includes student manuals and instructor guides with all the theory required to perform
the hands-on experiments.
• All workstations, modules, and components are very sturdy to ensure a prolonged service life in a
demanding environment such as a training laboratory.
• The modular design approach of the training equipment allows a large variety of courses to be
performed using a small number of modules, without unnecessary duplication of equipment.
• All electrical components can be interconnected without electric shock hazard since all live parts of the
connection leads are concealed and insulated.
• All electrical symbols representing the components used in a laboratory exercise are clearly silk-
screened on the front panel of the modules.
• The training system includes two highly versatile USB peripherals:
Four-Quadrant Dynamometer/Power Supply, Model 8960-2. This module is used as a dc and ac power
source.
Data Acquisition and Control Interface, Model 9063. This module gives access to a large variety of
computer-based measuring instruments via the LVDAC-EMS software.
• Software upgrades for LVDAC-EMS and firmware upgrades for the Four-Quadrant Dynamometer/Power
Supply and Data Acquisition and Control Interface are available for download free of charge on the
Festo Didactic website.
49 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
List of Equipment
Model
Qty Description
number
1 DC Power Circuits (Student Manual) _______________________________________________ 579339 (86350-00)
1 DC Power Circuits (Instructor Guide) _______________________________________________ 579341 (8635010)
1 Single-Phase AC Power Circuits (Student Manual) ____________________________________ 579366 (86358-00)
1 Single-Phase AC Power Circuits (Instructor Guide) ____________________________________ 579368 (8635810)
1 Three-Module Workstation ________________________________________________________ 579483 (8131-00)
1 Resistive Load __________________________________________________________________ 763359 (8311-00)
1 Inductive Load __________________________________________________________________ 763362 (8321-00)
1 Capacitive Load _________________________________________________________________ 763366 (8331-00)
1 Connection Lead Set ______________________________________________________________ 579638 (8951L0)
1 Four-Quadrant Dynamometer / Power Supply with Manual and Computer-Based Control _____ 579648 (8960C0)
1 Data Acquisition and Control Interface ______________________________________________ 579680 (9063B0)
1 AC 24 V Wall Mount Power Supply _________________________________________________ 579696 (3000420)
List of Manuals
Manual
Description
number
DC Power Circuits (Workbook) ________________________________________________________579339 (86350-00)
DC Power Circuits (Workbook (Instructor)) ______________________________________________ 579341 (8635010)
Single-Phase AC Power Circuits (Workbook) _____________________________________________579366 (86358-00)
Single-Phase AC Power Circuits (Workbook (Instructor)) ___________________________________ 579368 (8635810)
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
© Festo Didactic 50
Electric Power Technology Training Systems, LabVolt Series
Optional Equipment
Model
Qty Description
number
1 Full-Size Blank EMS Module ______________________________________________________ 579757 (8160-00) 2
1 Half-Size Blank EMS Module _____________________________________________________ 579758 (8161-00) 3
1 Multimeters Module _____________________________________________________________ 586888 (8946A0) 4
Software
Model
Qty Description
number
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 1 User Online, 1 year _____ 586971 (8972-00) 5
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 5 Users Online, 1 year _____ 586974 (8972A0) 6
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 10 Users Online, 1 year ____ 586977 (8972B0) 7
1 The data acquisition already includes this function and many more, but the DC Circuits manual references using multimeters.
2 To mount your own devices.
3 To mount your own devices.
4 Can replace the Digital Multimeters.
5 Simulation software that covers these topics as well as transformers, motors, generators and transmission lines.
6 Simulation software that covers these topics as well as transformers, motors, generators and transmission lines.
7 Simulation software that covers these topics as well as transformers, motors, generators and transmission lines.
51 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Model
Qty Description
number
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 15 Users Online, 1 year ____ 586980 (8972C0) 8
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 20 Users Online, 1 year ____ 586983 (8972D0) 9
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 25 Users Online, 1 year ___ 586986 (8972E0) 10
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 30 Users Online, 1 year ___ 586989 (8972F0) 11
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 40 Users Online, 1 year ___ 586995 (8972H0) 12
System Specifications
Parameter Value
Power Requirements
Service Installation A standard single-phase ac outlet
A currently available personal computer with USB 2.0 ports, running under one of the following operating
Computer Requirements
systems: Windows® 7 or Windows® 8.
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 900 x 930 x 530 mm (35.4 x 36.6 x 20.9 in)
Net Weight TBE
EMS Modules
Full-Size Dimensions (H x W x D) 308 x 287 x 440 mm (12.1 x 11.3 x 17.3 in)
Half-Size Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
8 Simulation software that covers these topics as well as transformers, motors, generators and transmission lines.
9 Simulation software that covers these topics as well as transformers, motors, generators and transmission lines.
10 Simulation software that covers these topics as well as transformers, motors, generators and transmission lines.
11 Simulation software that covers these topics as well as transformers, motors, generators and transmission lines.
12 Simulation software that covers these topics as well as transformers, motors, generators and transmission lines.
© Festo Didactic 52
Electric Power Technology Training Systems, LabVolt Series
technologies (SVC, STATCOM, HVDC transmission, etc.), storage of electrical energy in batteries, and drive
systems for small electric vehicles and cars.
The above chart shows all courses in the Electric Power Technology Training Program. Blue boxes highlight courses included in the
training system covered in this datasheet, while dark grey boxes, if any, highlight courses that can be optionally added to this
training system.
Courseware
Each course in the training system includes a full-color student manual providing all the theoretical matter
required, guided lab-exercise procedures to be performed with the training equipment, and review questions
that test the knowledge gained by the student. Whenever possible, each course is built to bring the student to
actual applications as soon as possible. A full-color instructor guide providing all lab results and answers to
questions is also included with each course.
53 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
• The training system allows easy experimentation with the operation of solar panels and the storage of
electrical energy in batteries.
• Solar panel experiments can be performed both indoors, using the solar panel test bench as light
source, or outdoors, using sunlight.
• The course curriculum of the Electric Power Technology Training Program is highly flexible and allows a
multitude of different customized training solutions.
• The courseware includes student manuals and instructor guides with all the theory required to perform
the hands-on experiments.
• All workstations, modules, and components are very sturdy to ensure a prolonged service life in a
demanding environment such as a training laboratory.
• The modular design approach of the training equipment allows a large variety of courses to be
performed using a small number of modules, without unnecessary duplication of equipment.
• All electrical components can be interconnected without electric shock hazard since all live parts of the
connection leads are concealed and insulated.
• All electrical symbols representing the components used in a laboratory exercise are clearly silk-
screened on the front panel of the modules.
List of Equipment
Model
Qty Description
number
1 DC Power Circuits (Student Manual) _______________________________________________ 579339 (86350-00)
1 DC Power Circuits (Instructor Guide) _______________________________________________ 579341 (8635010)
1 Solar Power (Student Manual) ____________________________________________________ 579347 (86352-00)
1 Solar Power (Instructor Guide) ____________________________________________________ 579349 (8635210)
1 Three-Module Workstation ________________________________________________________ 579483 (8131-00)
1 Resistive Load __________________________________________________________________ 763359 (8311-00)
1 Lead-Acid Batteries ______________________________________________________________ 763374 (8801-00)
© Festo Didactic 54
Electric Power Technology Training Systems, LabVolt Series
Model
Qty Description
number
1 Solar Panel Test Bench ___________________________________________________________ 579594 (8805-00)
1 Monocrystalline Silicon Solar Panel _________________________________________________ 579600 (8806-00)
1 Connection Lead Set ______________________________________________________________ 579638 (8951L0)
1 Four-Quadrant Dynamometer/Power Supply with manual control ________________________ 579641 (8960B0)
List of Manuals
Manual
Description
number
DC Power Circuits (Workbook) ________________________________________________________579339 (86350-00)
DC Power Circuits (Workbook (Instructor)) ______________________________________________ 579341 (8635010)
Solar Power (Workbook) _____________________________________________________________579347 (86352-00)
Solar Power (Workbook (Instructor)) ___________________________________________________ 579349 (8635210)
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
13 The data acquisition already includes this function and many more, but the DC Circuits manual references using multimeters.
55 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Courseware
Model
Qty Description
number
1 Solar Power Training System (Manuals on CD-ROM) __________________________________ 579703 (86352A0)
Optional Equipment
Model
Qty Description
number
1 Multimeters Module ____________________________________________________________ 586888 (8946A0) 14
System Specifications
Parameter Value
Power Requirements
Service Installation A standard single-phase ac outlet
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 900 x 930 x 530 mm (35.4 x 36.6 x 20.9 in)
Net Weight TBE
EMS Modules
Full-Size Dimensions (H x W x D) 308 x 287 x 440 mm (12.1 x 11.3 x 17.3 in)
Half-Size Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
© Festo Didactic 56
Electric Power Technology Training Systems, LabVolt Series
The Electric Power Technology Training Program is highly modular in both courseware and hardware. Because of
this, courses and equipment from the program are available as required, either individually or in the context of a
specific training system. The program covers several different subjects in the field of electrical energy, such as
rotating machines, electrical power transmission, power electronics, home energy production from renewable
resources (wind and sunlight), large-scale electricity production from hydropower and wind power, smart-grid
technologies (SVC, STATCOM, HVDC transmission, etc.), storage of electrical energy in batteries, and drive
systems for small electric vehicles and cars.
The above chart shows all courses in the Electric Power Technology Training Program. Blue boxes highlight courses included in the
training system covered in this datasheet, while dark grey boxes, if any, highlight courses that can be optionally added to this
training system.
57 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Courseware
Each course in the training system includes a full-color student manual providing all the theoretical matter
required, guided lab-exercise procedures to be performed with the training equipment, and review questions
that test the knowledge gained by the student. Whenever possible, each course is built to bring the student to
actual applications as soon as possible. A full-color instructor guide providing all lab results and answers to
questions is also included with each course.
• The training system teaches the basic principles of wind power electricity generation directly in the
laboratory.
• Wind speed and air density are simulated in the training system using a user-friendly and highly-
configurable wind emulator.
• All main components found in real wind turbines can be accessed separately in the Wind Turbine
Generator/Controller, Model 8216.
• The course curriculum of the Electric Power Technology Training Program is highly flexible and allows a
multitude of different customized training solutions.
• The courseware includes student manuals and instructor guides with all the theory required to perform
the hands-on experiments.
• All workstations, modules, and components are very sturdy to ensure a prolonged service life in a
demanding environment such as a training laboratory.
• The modular design approach of the training equipment allows a large variety of courses to be
performed using a small number of modules, without unnecessary duplication of equipment.
• All electrical components can be interconnected without electric shock hazard since all live parts of the
connection leads are concealed and insulated.
• All electrical symbols representing the components used in a laboratory exercise are clearly silk-
screened on the front panel of the modules.
© Festo Didactic 58
Electric Power Technology Training Systems, LabVolt Series
List of Equipment
Model
Qty Description
number
1 DC Power Circuits (Student Manual) _______________________________________________ 579339 (86350-00)
1 DC Power Circuits (Instructor Guide) _______________________________________________ 579341 (8635010)
1 Lead-Acid Batteries (Student Manual) ______________________________________________ 579343 (86351-00)
1 Lead-Acid Batteries (Instructor Guide) ______________________________________________ 579345 (8635110)
1 Introduction to Wind Power (Student Manual) _______________________________________ 579351 (86353-00)
1 Introduction to Wind Power (Instructor Guide) _______________________________________ 579353 (8635310)
1 Three-Module Workstation ________________________________________________________ 579483 (8131-00)
1 Wind Turbine Generator/Controller _________________________________________________ 579487 (8216-00)
1 Resistive Load __________________________________________________________________ 763359 (8311-00)
1 Lead-Acid Batteries ______________________________________________________________ 763374 (8801-00)
1 Lead-Acid Battery Pack ___________________________________________________________ 579591 (880210)
1 Timing Belt _____________________________________________________________________ 579637 (8942-00)
1 Connection Lead Set ______________________________________________________________ 579638 (8951L0)
1 Four-Quadrant Dynamometer/Power Supply _________________________________________ 579655 (8960D0)
List of Manuals
Manual
Description
number
DC Power Circuits (Workbook) ________________________________________________________579339 (86350-00)
DC Power Circuits (Workbook (Instructor)) ______________________________________________ 579341 (8635010)
Lead-Acid Batteries (Workbook) _______________________________________________________579343 (86351-00)
Lead-Acid Batteries (Workbook (Instructor)) _____________________________________________ 579345 (8635110)
Introduction to Wind Power (Workbook) ________________________________________________579351 (86353-00)
Introduction to Wind Power (Workbook (Instructor)) ______________________________________ 579353 (8635310)
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
59 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Optional Equipment
Model
Qty Description
number
1 Multimeters Module ____________________________________________________________ 586888 (8946A0) 16
15 The data acquisition already includes this function and many more, but the DC Circuits manual references using multimeters.
16 Can replace the Digital Multimeters.
© Festo Didactic 60
Electric Power Technology Training Systems, LabVolt Series
provided with each training system covers all the theory required to perform the laboratory exercises, while
review questions and unit tests allow students to test the knowledge they have gained.
The Electric Power Technology Training Program is highly modular in both courseware and hardware. Because of
this, courses and equipment from the program are available as required, either individually or in the context of a
specific training system. The program covers several different subjects in the field of electrical energy, such as
rotating machines, electrical power transmission, power electronics, home energy production from renewable
resources (wind and sunlight), large-scale electricity production from hydropower and wind power, smart-grid
technologies (SVC, STATCOM, HVDC transmission, etc.), storage of electrical energy in batteries, and drive
systems for small electric vehicles and cars.
The above chart shows all courses in the Electric Power Technology Training Program. Blue boxes highlight courses included in the
training system covered in this datasheet, while dark grey boxes, if any, highlight courses that can be optionally added to this
training system.
61 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Courseware
Each course in the training system includes a full-color student manual providing all the theoretical matter
required, guided lab-exercise procedures to be performed with the training equipment, and review questions
that test the knowledge gained by the student. Whenever possible, each course is built to bring the student to
actual applications as soon as possible. A full-color instructor guide providing all lab results and answers to
questions is also included with each course.
• The training system teaches the principles of lead-acid battery operation during both charge and
discharge.
• The course curriculum of the Electric Power Technology Training Program is highly flexible and allows a
multitude of different customized training solutions.
• The courseware includes student manuals and instructor guides with all the theory required to perform
the hands-on experiments.
• All workstations, modules, and components are very sturdy to ensure a prolonged service life in a
demanding environment such as a training laboratory.
• The modular design approach of the training equipment allows a large variety of courses to be
performed using a small number of modules, without unnecessary duplication of equipment.
• All electrical components can be interconnected without electric shock hazard since all live parts of the
connection leads are concealed and insulated.
• All electrical symbols representing the components used in a laboratory exercise are clearly silk-
screened on the front panel of the modules.
• The training system includes a highly versatile USB peripheral:
Four-Quadrant Dynamometer/Power Supply, Model 8960-2. This module is used as a dc power
source and a battery charger/discharger with a large variety of configurable parameters. It can also
be used as an overnight battery float charger.
© Festo Didactic 62
Electric Power Technology Training Systems, LabVolt Series
• Firmware upgrades for the Four-Quadrant Dynamometer/Power Supply are available for download free
of charge on the Festo Didactic website.
List of Equipment
Model
Qty Description
number
1 DC Power Circuits (Student Manual) _______________________________________________ 579339 (86350-00)
1 DC Power Circuits (Instructor Guide) _______________________________________________ 579341 (8635010)
1 Lead-Acid Batteries (Student Manual) ______________________________________________ 579343 (86351-00)
1 Lead-Acid Batteries (Instructor Guide) ______________________________________________ 579345 (8635110)
1 Three-Module Workstation ________________________________________________________ 579483 (8131-00)
1 Resistive Load __________________________________________________________________ 763359 (8311-00)
1 Lead-Acid Batteries ______________________________________________________________ 763374 (8801-00)
1 Connection Lead Set ______________________________________________________________ 579638 (8951L0)
1 Four-Quadrant Dynamometer/Power Supply __________________________________________ 579662 (8960E0)
List of Manuals
Manual
Description
number
DC Power Circuits (Workbook) ________________________________________________________579339 (86350-00)
DC Power Circuits (Workbook (Instructor)) ______________________________________________ 579341 (8635010)
Lead-Acid Batteries (Workbook) _______________________________________________________579343 (86351-00)
Lead-Acid Batteries (Workbook (Instructor)) _____________________________________________ 579345 (8635110)
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
63 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Optional Equipment
Model
Qty Description
number
1 Multimeters Module ____________________________________________________________ 586888 (8946A0) 18
System Specifications
Parameter Value
Power Requirements
Service Installation A standard single-phase ac outlet
A currently available personal computer with USB 2.0 ports, running under one of the following operating
Computer Requirements
systems: Windows® 7 or Windows® 8.
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 900 x 930 x 530 mm (35.4 x 36.6 x 20.9 in)
Net Weight TBE
EMS Modules
Full-Size Dimensions (H x W x D) 308 x 287 x 440 mm (12.1 x 11.3 x 17.3 in)
Half-Size Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
17 The data acquisition already includes this function and many more, but the DC Circuits manual references using multimeters.
18 Can replace the Digital Multimeters.
© Festo Didactic 64
Electric Power Technology Training Systems, LabVolt Series
technologies (SVC, STATCOM, HVDC transmission, etc.), storage of electrical energy in batteries, and drive
systems for small electric vehicles and cars.
The above chart shows all courses in the Electric Power Technology Training Program. Blue boxes highlight courses included in the
training system covered in this datasheet, while dark grey boxes, if any, highlight courses that can be optionally added to this
training system.
Courseware
Each course in the training system includes a full-color student manual providing all the theoretical matter
required, guided lab-exercise procedures to be performed with the training equipment, and review questions
that test the knowledge gained by the student. Whenever possible, each course is built to bring the student to
actual applications as soon as possible. A full-color instructor guide providing all lab results and answers to
questions is also included with each course.
65 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
• The training system teaches the principles of electricity generation from renewable energy sources
(solar power and wind power), as well as its subsequent storage in lead-acid batteries.
• The course curriculum of the Electric Power Technology Training Program is highly flexible and allows a
multitude of different customized training solutions.
• The courseware includes student manuals and instructor guides with all the theory required to perform
the hands-on experiments.
• All workstations, modules, and components are very sturdy to ensure a prolonged service life in a
demanding environment such as a training laboratory.
• The modular design approach of the training equipment allows a large variety of courses to be
performed using a small number of modules, without unnecessary duplication of equipment.
• All electrical components can be interconnected without electric shock hazard since all live parts of the
connection leads are concealed and insulated.
• All electrical symbols representing the components used in a laboratory exercise are clearly silk-
screened on the front panel of the modules.
• The training system includes a highly versatile USB peripheral:
Four-Quadrant Dynamometer/Power Supply, Model 8960-2. This module is used as a dc power
source and a battery charger/discharger with a large variety of configurable parameters. It is also
used to simulate different wind conditions through a large variety of configurable parameters.
• Firmware upgrades for the Four-Quadrant Dynamometer/Power Supply are available for download free
of charge on the Festo Didactic website.
List of Equipment
Model
Qty Description
number
1 DC Power Circuits (Student Manual) _______________________________________________ 579339 (86350-00)
1 DC Power Circuits (Instructor Guide) _______________________________________________ 579341 (8635010)
1 Lead-Acid Batteries (Student Manual) ______________________________________________ 579343 (86351-00)
1 Lead-Acid Batteries (Instructor Guide) ______________________________________________ 579345 (8635110)
© Festo Didactic 66
Electric Power Technology Training Systems, LabVolt Series
Model
Qty Description
number
1 Solar Power (Student Manual) ____________________________________________________ 579347 (86352-00)
1 Solar Power (Instructor Guide) ____________________________________________________ 579349 (8635210)
1 Introduction to Wind Power (Student Manual) _______________________________________ 579351 (86353-00)
1 Introduction to Wind Power (Instructor Guide) _______________________________________ 579353 (8635310)
1 Three-Module Workstation ________________________________________________________ 579483 (8131-00)
1 Wind Turbine Generator/Controller _________________________________________________ 579487 (8216-00)
1 Resistive Load __________________________________________________________________ 763359 (8311-00)
1 Lead-Acid Batteries ______________________________________________________________ 763374 (8801-00)
1 Lead-Acid Battery Pack ___________________________________________________________ 579591 (880210)
1 Solar Panel Test Bench ___________________________________________________________ 579594 (8805-00)
1 Monocrystalline Silicon Solar Panel _________________________________________________ 579600 (8806-00)
1 Timing Belt _____________________________________________________________________ 579637 (8942-00)
1 Connection Lead Set ______________________________________________________________ 579638 (8951L0)
1 Four-Quadrant Dynamometer/Power Supply _________________________________________ 579655 (8960D0)
List of Manuals
Manual
Description
number
DC Power Circuits (Workbook) ________________________________________________________579339 (86350-00)
DC Power Circuits (Workbook (Instructor)) ______________________________________________ 579341 (8635010)
Lead-Acid Batteries (Workbook) _______________________________________________________579343 (86351-00)
Lead-Acid Batteries (Workbook (Instructor)) _____________________________________________ 579345 (8635110)
Solar Power (Workbook) _____________________________________________________________579347 (86352-00)
Solar Power (Workbook (Instructor)) ___________________________________________________ 579349 (8635210)
Introduction to Wind Power (Workbook) ________________________________________________579351 (86353-00)
Introduction to Wind Power (Workbook (Instructor)) ______________________________________ 579353 (8635310)
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
67 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
• 2 Discharge Characteristics
• 3 Battery Charging Fundamentals
• 4 Battery Charging Methods
Courseware
Model
Qty Description
number
1 Basic Renewable Energy Training System (Manuals on CD-ROM) ________________________ 579753 (89338A0)
19 The data acquisition already includes this function and many more, but the DC Circuits manual references using multimeters.
© Festo Didactic 68
Electric Power Technology Training Systems, LabVolt Series
Optional Equipment
Model
Qty Description
number
1 Full-Size Blank EMS Module _____________________________________________________ 579757 (8160-00) 20
1 Half-Size Blank EMS Module ____________________________________________________ 579758 (8161-00) 21
1 Wind Turbine Generator/Controller _______________________________________________ 579487 (8216-00) 22
1 Wind Turbine Demonstrator ______________________________________________________ 579766 (8216D0) 23
1 Polycristalline Silicon Solar Panel ________________________________________________ 8106942 (8806A0) 24
1 Multimeters Module ____________________________________________________________ 586888 (8946A0) 25
1 Pyranometer _________________________________________________________________ 579784 (8989-00) 26
1 Heavy-Duty Tripod _____________________________________________________________ 583216 (4020810) 27
1 Wind Turbine Rotor ___________________________________________________________ 579794 (86630-00) 28
Optional Measurement
Model
Qty Description
number
1 Magnetic Field Strength Indicator _________________________________________________ 579793 (86618-00)
Software
Model
Qty Description
number
1 Software Development Kit (SDK) __________________________________________________ 581441 (896870) 29
1 SCADA for LVDAC-EMS ________________________________________________________ 8094377 (8973-00) 30
1 Software Development Kit (SDK) __________________________________________________ 581459 (906990) 31
Workstation
Model
Qty Description
number
1 Mobile Workstation _____________________________________________________________ 579755 (811020) 32
1 Tabletop Workstation ___________________________________________________________ 579484 (813420) 33
System Specifications
Parameter Value
Power Requirements
Service Installation A standard single-phase ac outlet
A currently available personal computer with USB 2.0 ports, running under one of the following operating
Computer Requirements
systems: Windows® 7 or Windows® 8.
69 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Parameter Value
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 900 x 930 x 530 mm (35.4 x 36.6 x 20.9 in)
Net Weight TBE
EMS Modules
Full-Size Dimensions (H x W x D) 308 x 287 x 440 mm (12.1 x 11.3 x 17.3 in)
Half-Size Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
© Festo Didactic 70
Electric Power Technology Training Systems, LabVolt Series
The above chart shows all courses in the Electric Power Technology Training Program. Blue boxes highlight courses included in the
training system covered in this datasheet, while dark grey boxes, if any, highlight courses that can be optionally added to this
training system.
Courseware
Each course in the training system includes a full-color student manual providing all the theoretical matter
required, guided lab-exercise procedures to be performed with the training equipment, and review questions
that test the knowledge gained by the student. Whenever possible, each course is built to bring the student to
actual applications as soon as possible. A full-color instructor guide providing all lab results and answers to
questions is also included with each course.
71 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
• The training system teaches the principles of dc power electronics, as well as the operation of various
dc power electronics devices, through clear, easy-to-follow theory presentations and simple,
demonstrative hands-on exercises.
• The course curriculum of the Electric Power Technology Training Program is highly flexible and allows a
multitude of different customized training solutions.
• The courseware includes student manuals and instructor guides with all the theory required to perform
the hands-on experiments.
• All workstations, modules, and components are very sturdy to ensure a prolonged service life in a
demanding environment such as a training laboratory.
• The modular design approach of the training equipment allows a large variety of courses to be
performed using a small number of modules, without unnecessary duplication of equipment.
• All electrical components can be interconnected without electric shock hazard since all live parts of the
connection leads are concealed and insulated.
• All electrical symbols representing the components used in a laboratory exercise are clearly silk-
screened on the front panel of the modules.
• The training system includes two highly versatile USB peripherals:
Four-Quadrant Dynamometer/Power Supply, Model 8960-2. This module is used as a dc power
source and a battery charger/discharger with a large variety of configurable parameters. The module
can also be used as an overnight battery float charger.
Data Acquisition and Control Interface, Model 9063. This module gives access to a large variety of
computer-based measuring instruments and is used to control the various dc power electronics
devices. Both of these functions are implemented via the LVDAC-EMS software.
• Software upgrades for LVDAC-EMS and firmware upgrades for the Four-Quadrant Dynamometer/Power
Supply and Data Acquisition and Control Interface are available for download free of charge on the
Festo Didactic website.
© Festo Didactic 72
Electric Power Technology Training Systems, LabVolt Series
List of Equipment
Model
Qty Description
number
1 DC Power Circuits (Student Manual) _______________________________________________ 579339 (86350-00)
1 DC Power Circuits (Instructor Guide) _______________________________________________ 579341 (8635010)
1 DC Power Electronics (Student Manual) ____________________________________________ 579358 (86356-00)
1 DC Power Electronics (Instructor Guide) ____________________________________________ 579360 (8635610)
1 Three-Module Workstation ________________________________________________________ 579483 (8131-00)
1 Resistive Load __________________________________________________________________ 763359 (8311-00)
1 Filtering Inductors/Capacitors _____________________________________________________ 579523 (8325A0)
1 Lead-Acid Battery Pack ___________________________________________________________ 579591 (880210)
1 IGBT Chopper/Inverter ___________________________________________________________ 579623 (8837B0)
1 Connection Lead Set ______________________________________________________________ 579638 (8951L0)
1 Four-Quadrant Dynamometer/Power Supply __________________________________________ 579662 (8960E0)
1 Data Acquisition and Control Interface ______________________________________________ 579683 (9063C0)
1 AC 24 V Wall Mount Power Supply _________________________________________________ 579696 (3000420)
List of Manuals
Manual
Description
number
DC Power Circuits (Workbook) ________________________________________________________579339 (86350-00)
DC Power Circuits (Workbook (Instructor)) ______________________________________________ 579341 (8635010)
DC Power Electronics (Workbook) _____________________________________________________579358 (86356-00)
DC Power Electronics (Workbook (Instructor)) ___________________________________________ 579360 (8635610)
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
73 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Optional Equipment
Model
Qty Description
number
1 Multimeters Module ____________________________________________________________ 586888 (8946A0) 35
System Specifications
Parameter Value
Power Requirements
Service Installation A standard single-phase ac outlet
A currently available personal computer with USB 2.0 ports, running under one of the following operating
Computer Requirements
systems: Windows® 7 or Windows® 8.
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 900 x 930 x 530 mm (35.4 x 36.6 x 20.9 in)
Net Weight TBE
EMS Modules
Full-Size Dimensions (H x W x D) 308 x 287 x 440 mm (12.1 x 11.3 x 17.3 in)
Half-Size Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
34 The data acquisition already includes this function and many more, but the DC Circuits manual references using multimeters.
35 Can replace the Digital Multimeters.
© Festo Didactic 74
Electric Power Technology Training Systems, LabVolt Series
• DC Power Circuits
• Lead-Acid Batteries
• Solar Power
• Introduction to Wind Power
These courses introduce students to the fundamentals of dc power circuits, to the storage of electrical energy in
lead-acid batteries, and to the generation of electrical energy from wind and sunlight, the two renewable
resources most commonly used for home energy production. Training continues with the following two courses
dealing with ac power:
These courses teach students the fundamentals of ac power circuits and power transformers, and are necessary
to understand the principles of grid-tied home energy production. Students then continue with the following
three courses:
• DC Power Electronics
• Single-Phase AC Power Electronics
• High-Frequency Power Transformers
These courses familiarize students with the different power electronics devices used for home energy
production, such as choppers, inverters, dc-to-dc converters, and high-frequency power transformers. After
completion of the above courses, students finally possess all knowledge required to proceed with the main
course of the training system:
This course familiarizes students with the fundamentals of home energy production. It integrates all the
different notions which students have acquired in the previous courses to cover both stand-alone home energy
production and grid-tied home energy production. The course also explains and demonstrates how home
energy production is an important contributor to the implementation of a smart grid, a concept of ever growing
importance in today's electric power networks.
The Home Energy Production Training System is part of the Electric Power Technology Training Systems, Series
8010. Each training system in Series 8010 is based on the Electric Power Technology Training Program and
provides a turn-key solution dealing with some aspects of the wide field of electrical energy. The exhaustive
75 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
courseware provided with each training system covers all the theory required to perform the laboratory
exercises, while review questions and unit tests allow students to test the knowledge they have gained.
The Electric Power Technology Training Program is highly modular in both courseware and hardware. Because of
this, courses and equipment from the program are available as required, either individually or in the context of a
specific training system. The program covers several different subjects in the field of electrical energy, such as
rotating machines, electrical power transmission, power electronics, home energy production from renewable
resources (wind and sunlight), large-scale electricity production from hydropower and wind power, smart-grid
technologies (SVC, STATCOM, HVDC transmission, etc.), storage of electrical energy in batteries, and drive
systems for small electric vehicles and cars.
The above chart shows all courses in the Electric Power Technology Training Program. Blue boxes highlight courses included in the
training system covered in this datasheet, while dark grey boxes, if any, highlight courses that can be optionally added to this
training system.
© Festo Didactic 76
Electric Power Technology Training Systems, LabVolt Series
Courseware
Each course in the training system includes a full-color student manual providing all the theoretical matter
required, guided lab-exercise procedures to be performed with the training equipment, and review questions
that test the knowledge gained by the student. Whenever possible, each course is built to bring the student to
actual applications as soon as possible. A full-color instructor guide providing all lab results and answers to
questions is also included with each course.
• The training system teaches the principles of home energy production directly in the laboratory. To this
end, students follow a complete curriculum that includes these topics:
An introduction to the fundamentals of electricity, beginning with dc power circuits.
Courses that cover the principles of electricity generation from renewable energy sources (solar
power and wind power), as well as its subsequent storage in lead-acid batteries.
More advanced courses that cover different electrical concepts and necessary to home energy
production, such as dc power electronics, single-phase ac power circuits, and high-frequency power
transformers.
A comprehensive course covering in detail the production of energy at home from renewable
resources.
• The course curriculum of the Electric Power Technology Training Program is highly flexible and allows a
multitude of different customized training solutions.
• The courseware includes student manuals and instructor guides with all the theory required to perform
the hands-on experiments.
• All workstations, modules, and components are very sturdy to ensure a prolonged service life in a
demanding environment such as a training laboratory.
• The modular design approach of the training equipment allows a large variety of courses to be
performed using a small number of modules, without unnecessary duplication of equipment.
• All electrical components can be interconnected without electric shock hazard since all live parts of the
connection leads are concealed and insulated.
77 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
• All electrical symbols representing the components used in a laboratory exercise are clearly silk-
screened on the front panel of the modules.
• The training system includes two highly versatile USB peripherals:
Four-Quadrant Dynamometer/Power Supply, Model 8960-2. This module is used as a dc and ac power
source. It can also be used as a battery charger/discharger, a solar panel emulator, and a wind
emulator, all with a large variety of configurable parameters.
Data Acquisition and Control Interface, Model 9063. This module gives access to a large variety of
computer-based measuring instruments and is used to control the various dc power electronics
devices necessary to home energy production. All functions are implemented via the LVDAC-EMS
software.
• The training system also includes three highly versatile power electronics modules controlled using the
Data Acquisition and Control Interface:
Insulated DC-to-DC Converter, Model 8835. This module is used to implement a solar/wind power
inverter with HF transformer topology.
IGBT Chopper/Inverter, Model 8837-B. This module is used to implement various types of choppers
and inverters.
Rectifier and Filtering Capacitors, Model 8842-A. This module is used to implement various types of
power diode rectifiers.
• Software upgrades for LVDAC-EMS and firmware upgrades for the Four-Quadrant Dynamometer/Power
Supply and Data Acquisition and Control Interface are available for download free of charge on the
Festo Didactic website.
List of Equipment
Model
Qty Description
number
1 DC Power Circuits (Student Manual) _______________________________________________ 579339 (86350-00)
1 DC Power Circuits (Instructor Guide) _______________________________________________ 579341 (8635010)
1 Lead-Acid Batteries (Student Manual) ______________________________________________ 579343 (86351-00)
1 Lead-Acid Batteries (Instructor Guide) ______________________________________________ 579345 (8635110)
1 Solar Power (Student Manual) ____________________________________________________ 579347 (86352-00)
1 Solar Power (Instructor Guide) ____________________________________________________ 579349 (8635210)
1 Introduction to Wind Power (Student Manual) _______________________________________ 579351 (86353-00)
1 Introduction to Wind Power (Instructor Guide) _______________________________________ 579353 (8635310)
1 DC Power Electronics (Student Manual) ____________________________________________ 579358 (86356-00)
1 DC Power Electronics (Instructor Guide) ____________________________________________ 579360 (8635610)
1 Single-Phase AC Power Circuits (Student Manual) ____________________________________ 579366 (86358-00)
1 Single-Phase AC Power Circuits (Instructor Guide) ____________________________________ 579368 (8635810)
1 Single-Phase AC Power Electronics (Student Manual) _________________________________ 579370 (86359-00)
1 Single-Phase AC Power Electronics (Instructor Guide) _________________________________ 579372 (8635910)
1 Home Energy Production (Student Manual) _________________________________________ 579385 (86361-00)
1 Home Energy Production (Instructor Guide) _________________________________________ 579387 (8636110)
1 Single-Phase Power Transformer (Student Manual) ___________________________________ 579437 (86377-00)
1 Single-Phase Power Transformer (Instructor Guide) ___________________________________ 579439 (8637710)
1 High-Frequency Power Transformer (Student Manual) _________________________________ 579441 (86378-00)
1 High-Frequency Power Transformer (Instructor Guide) _________________________________ 579443 (8637810)
1 Tabletop Workstation ____________________________________________________________ 579484 (813420)
1 Wind Turbine Generator/Controller _________________________________________________ 579487 (8216-00)
1 Resistive Load __________________________________________________________________ 763359 (8311-00)
© Festo Didactic 78
Electric Power Technology Training Systems, LabVolt Series
Model
Qty Description
number
1 Inductive Load __________________________________________________________________ 763362 (8321-00)
1 Filtering Inductors/Capacitors _____________________________________________________ 579523 (8325A0)
1 Capacitive Load _________________________________________________________________ 763366 (8331-00)
1 Transformer ____________________________________________________________________ 763371 (8353-00)
1 AC Power Network Interface _______________________________________________________ 579581 (8622-00)
1 Lead-Acid Batteries ______________________________________________________________ 763374 (8801-00)
1 Lead-Acid Battery Pack ___________________________________________________________ 579591 (880210)
1 Solar Panel Test Bench ___________________________________________________________ 579594 (8805-00)
1 Monocrystalline Silicon Solar Panel _________________________________________________ 579600 (8806-00)
1 Insulated DC-to-DC Converter _____________________________________________________ 579618 (8835-00)
1 IGBT Chopper/Inverter ___________________________________________________________ 579623 (8837B0)
1 Rectifier and Filtering Capacitors ___________________________________________________ 579630 (8842A0)
1 Timing Belt _____________________________________________________________________ 579637 (8942-00)
1 Connection Lead Set ______________________________________________________________ 579638 (8951L0)
1 Four-Quadrant Dynamometer/Power Supply __________________________________________ 579669 (8960F0)
1 Data Acquisition and Control Interface _______________________________________________ 579689 (9063E0)
1 AC 24 V Wall Mount Power Supply _________________________________________________ 579696 (3000420)
List of Manuals
Manual
Description
number
DC Power Circuits (Workbook) ________________________________________________________579339 (86350-00)
DC Power Circuits (Workbook (Instructor)) ______________________________________________ 579341 (8635010)
Lead-Acid Batteries (Workbook) _______________________________________________________579343 (86351-00)
Lead-Acid Batteries (Workbook (Instructor)) _____________________________________________ 579345 (8635110)
Solar Power (Workbook) _____________________________________________________________579347 (86352-00)
Solar Power (Workbook (Instructor)) ___________________________________________________ 579349 (8635210)
Introduction to Wind Power (Workbook) ________________________________________________579351 (86353-00)
Introduction to Wind Power (Workbook (Instructor)) ______________________________________ 579353 (8635310)
DC Power Electronics (Workbook) _____________________________________________________579358 (86356-00)
DC Power Electronics (Workbook (Instructor)) ___________________________________________ 579360 (8635610)
Single-Phase AC Power Circuits (Workbook) _____________________________________________579366 (86358-00)
Single-Phase AC Power Circuits (Workbook (Instructor)) ___________________________________ 579368 (8635810)
Single-Phase AC Power Electronics (Workbook) __________________________________________579370 (86359-00)
Single-Phase AC Power Electronics (Workbook (Instructor)) ________________________________ 579372 (8635910)
Home Energy Production (Workbook) __________________________________________________579385 (86361-00)
Home Energy Production (Workbook (Instructor)) ________________________________________ 579387 (8636110)
Single-Phase Power Transformers (Workbook) ___________________________________________579437 (86377-00)
Single-Phase Power Transformers (Workbook (Instructor)) _________________________________ 579439 (8637710)
High-Frequency Power Transformers (Workbook) ________________________________________ 579441 (86378-00)
High-Frequency Power Transformers (Workbook (Instructor)) _______________________________ 579443 (8637810)
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
79 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
• 2 Equivalent Resistance
• 3 Power in DC Circuits
• 4 Series and Parallel Circuits
© Festo Didactic 80
Electric Power Technology Training Systems, LabVolt Series
81 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Optional Equipment
Model
Qty Description
number
1 Full-Size Blank EMS Module _____________________________________________________ 579757 (8160-00) 38
1 Half-Size Blank EMS Module ____________________________________________________ 579758 (8161-00) 39
1 Wind Turbine Demonstrator ______________________________________________________ 579766 (8216D0) 40
1 Resistive Load __________________________________________________________________ 763359 (8311-00)
1 Polycristalline Silicon Solar Panel ________________________________________________ 8106942 (8806A0) 41
1 Variable Three-Phase Power Supply _______________________________________________ 579603 (882120) 42
1 Three-Phase Power Supply ______________________________________________________ 579612 (8823-00) 43
1 Multimeters Module ____________________________________________________________ 586888 (8946A0) 44
1 Pyranometer _________________________________________________________________ 579784 (8989-00) 45
1 Magnetic Field Strength Indicator _________________________________________________ 579793 (86618-00)
1 Wind Turbine Rotor _____________________________________________________________ 579794 (86630-00)
36 The data acquisition already includes this function and many more, but the DC Circuits manual references using multimeters.
37 Required for only one exercise.
38 To mount your own devices.
39 To mount your own devices.
40 Optional Demonstrator.
41 20 W photovoltaic panel that can be mounted on the side of an EMS Workstation or on any other vertical surface.
42 Variable three-phase power supply allows teaching three phase power circuits.
43 Fixed three-phase power supply allows teaching many three phase power circuits.
44 Can replace the Digital Multimeters.
45 To measure solar intensity. Used in one exercise only.
© Festo Didactic 82
Electric Power Technology Training Systems, LabVolt Series
Software
Model
Qty Description
number
1 Software Development Kit (SDK) __________________________________________________ 581441 (896870) 46
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 1 User Online, 1 year ____ 586971 (8972-00) 47
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 5 Users Online, 1 year ____ 586974 (8972A0) 48
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 10 Users Online, 1 year ___ 586977 (8972B0) 49
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 15 Users Online, 1 year ___ 586980 (8972C0) 50
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 20 Users Online, 1 year ___ 586983 (8972D0) 51
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 25 Users Online, 1 year ___ 586986 (8972E0) 52
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 30 Users Online, 1 year ___ 586989 (8972F0) 53
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 25 Users Online, 1 year ___ 586992 (8972G0) 54
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 40 Users Online, 1 year ___ 586995 (8972H0) 55
1 SCADA for LVDAC-EMS ________________________________________________________ 8094377 (8973-00) 56
1 Software Development Kit (SDK) __________________________________________________ 581459 (906990) 57
Workstation
Model
Qty Description
number
1 Mobile Workstation _____________________________________________________________ 579755 (811020) 58
1 Storage Shelves _________________________________________________________________ 579756 (815010)
1 Dust Cover for Workstations _______________________________________________________ 587004 (8991-00)
1 Dust Cover for EMS Storage Cabinet ________________________________________________ 587006 (8992-00)
1 Three-Phase Power Receptable - NEMA L22-20 ______________________________________ 768193 (24183-00)
1 Three-Phase Power Receptable - NEMA L21-20R _____________________________________ 768288 (24582-00)
1 Three-Phase Power Receptacle - 5-Pin Round ________________________________________ 775548 (35153-00)
1 External Shelf for the Mobile Workstation _________________________________________ 581465 (36653-00) 59
83 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Model
Qty Description
number
1 Mounting Stand with Articulating Arm ____________________________________________ 8108710 (36653A0) 60
1 Mobile Base _________________________________________________________________ 587518 (88863-00) 61
System Specifications
Parameter Value
Power Requirements
Service Installation A standard single-phase ac outlet
A currently available personal computer with USB 2.0 ports, running under one of the following operating
Computer Requirements
systems: Windows® 7 or Windows® 8.
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 900 x 930 x 530 mm (35.4 x 36.6 x 20.9 in)
Net Weight TBE
EMS Modules
Full-Size Dimensions (H x W x D) 308 x 287 x 440 mm (12.1 x 11.3 x 17.3 in)
Half-Size Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
• Electrical engineering
• Energy engineering
• Process engineering
• Mechanical engineering
• Automotive engineering
The Hydrogen Fuel Cell Training System includes numerous prepared experiments, enabling students to
examine the design and functions of a real fuel cell system. It is developed especially for educational purposes,
the system being designed for maximum safety and ease of use, even by inexperienced users. With this training
system, students explore the engineering principles of a hydrogen fuel cell system, as well as advanced general
principles related to the system, including:
© Festo Didactic 84
Electric Power Technology Training Systems, LabVolt Series
The Hydrogen Fuel Cell Training System is part of the Electric Power Technology Training Systems, Series 8010.
Each training system in Series 8010 is based on the Electric Power Technology Training Program and provides a
turn-key solution dealing with some aspects of the wide field of electrical energy. The exhaustive courseware
provided with each training system covers all the theory required to perform the laboratory exercises, while
review questions and unit tests allow students to test the knowledge they have gained.
The Electric Power Technology Training Program is highly modular in both courseware and hardware. Because of
this, courses and equipment from the program are available as required, either individually or in the context of a
specific training system. The program covers several different subjects in the field of electrical energy, such as
rotating machines, electrical power transmission, power electronics, home energy production from renewable
resources (wind and sunlight), large-scale electricity production from hydropower and wind power, smart-grid
technologies (SVC, STATCOM, HVDC transmission, etc.), storage of electrical energy in batteries, and drive
systems for small electric vehicles and cars.
Exercises
Theory:
Safety:
The Hydrogen Fuel Cell Training System is designed for maximum technical safety. Developed especially for
universities and vocational institutions, the system is designed for safe and easy operation by inexperienced
and experienced users. In case of overloads or irregularities, the trainer shuts down automatically and locks the
hydrogen supply. Therefore, you can take the system to its limits without the risk of safety hazards or damage.
Practice:
• Different test points with digital meters throughout the process for better understanding
• The training system teaches the principles of hydrogen fuel cell operation during both charge and
discharge directly in the laboratory.
• The hydrogen fuel cell modules are safe to use and present no risk to system users. The modules are
easy to setup by following the procedure detailed in the manuals.
85 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
• Sequential loads and fully adjustable loads allow study of hydrogen fuel cell system operation.
• A variety of test points with digital meters are included in the hydrogen fuel cell modules to observe the
different processes taking place.
• The course curriculum of the Electric Power Technology Training Program is highly flexible and allows a
multitude of different customized training solutions.
• The courseware includes student manuals and instructor guides with all the theory required to perform
the hands-on experiments.
• All workstations, modules, and components are very sturdy to ensure a prolonged service life in a
demanding environment such as a training laboratory.
• The modular design approach of the training equipment allows a large variety of courses to be
performed using a small number of modules, without unnecessary duplication of equipment.
• All electrical components can be interconnected without electric shock hazard since all live parts of the
connection leads are concealed and insulated.
• All electrical symbols representing the components used in a laboratory exercise are clearly silk-
screened on the front panel of the modules.
List of Equipment
Model
Qty Description
number
1 Three-Module Workstation ________________________________________________________ 579483 (8131-00)
1 Traffic Lights ___________________________________________________________________ 579574 (8380-00)
1 Electronic Load _________________________________________________________________ 579575 (8381-00)
1 Hydrogen Fuel Cell ______________________________________________________________ 579593 (8803-00)
1 Hydrogen Cylinder Connection Kit _________________________________________________ 780548 (52863-00)
1 Hydrogen Storage Canister _______________________________________________________ 579699 (87948-00)
List of Manuals
Manual
Description
number
Hydrogen Fuel Cell (Workbook) _______________________________________________________579355 (86355-00)
Hydrogen Fuel Cell (Workbook (Instructor)) _____________________________________________ 579356 (8635510)
Hydrogen Fuel Cell (User Guide) ______________________________________________________ 579357 (86355E0)
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
© Festo Didactic 86
Electric Power Technology Training Systems, LabVolt Series
87 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Courseware
Model
Qty Description
number
1 Manuals on CD-ROM – Hydrogen Fuel Cell Training System (Manuals on CD-ROM) __________ 579705 (86355A0)
© Festo Didactic 88
Electric Power Technology Training Systems, LabVolt Series
Optional Equipment
Model
Qty Description
number
1 Hydrogen Generator ___________________________________________________________ 579781 (8894-00) 62
1 Personal Computer ______________________________________________________________ 579785 (8990-00)
1 All-in-one computer _____________________________________________________________ 766480 (20628-00)
1 Touch-Screen Computer _________________________________________________________ 588298 (46299-00)
1 Touch-Screen Computer – Large ___________________________________________________ 589677 (46299A0)
Workstation
Model
Qty Description
number
1 Storage Shelves _________________________________________________________________ 579756 (815010)
System Specifications
Parameter Value
Power Requirements
Service Installation A standard single-phase ac outlet
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 900 x 930 x 530 mm (35.4 x 36.6 x 20.9 in)
Net Weight TBE
EMS Modules
Full-Size Dimensions (H x W x D) 308 x 287 x 440 mm (12.1 x 11.3 x 17.3 in)
Half-Size Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
62 Optional equipment if the user is not able to get Hydrogen from an industrial gas supplier.
89 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
compound dc motors, separately excited, shunt, and compound dc generators, universal motor, and single-
phase induction motor (capacitor-start and split-phase types). These machines, although still in use today, are
less common in modern applications.
The Electromechanical Training System is part of the Electric Power Technology Training Systems, Series 8010.
Each training system in Series 8010 is based on the Electric Power Technology Training Program and provides a
turn-key solution dealing with some aspects of the wide field of electrical energy. The exhaustive courseware
provided with each training system covers all the theory required to perform the laboratory exercises, while
review questions and unit tests allow students to test the knowledge they have gained.
The Electric Power Technology Training Program is highly modular in both courseware and hardware. Because of
this, courses and equipment from the program are available as required, either individually or in the context of a
specific training system. The program covers several different subjects in the field of electrical energy, such as
rotating machines, electrical power transmission, power electronics, home energy production from renewable
resources (wind and sunlight), large-scale electricity production from hydropower and wind power, smart-grid
technologies (SVC, STATCOM, HVDC transmission, etc.), storage of electrical energy in batteries, and drive
systems for small electric vehicles and cars.
© Festo Didactic 90
Electric Power Technology Training Systems, LabVolt Series
The above chart shows all courses in the Electric Power Technology Training Program. Blue boxes highlight courses included in the
training system covered in this datasheet, while dark grey boxes, if any, highlight courses that can be optionally added to this
training system.
Courseware
Each course in the training system includes a full-color student manual providing all the theoretical matter
required, guided lab-exercise procedures to be performed with the training equipment, and review questions
that test the knowledge gained by the student. Whenever possible, each course is built to bring the student to
actual applications as soon as possible. A full-color instructor guide providing all lab results and answers to
questions is also included with each course.
91 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
• The training system teaches the principles of three-phase rotating machines. To this end, students
follow a complete curriculum that includes these topics:
An introduction to the fundamentals of electricity, beginning with dc power circuits and ac power
circuits.
More advanced courses that cover different concepts and devices important to the study of three-
phase rotating machines, such as single-phase and three-phase ac power circuits, single-phase and
three-phase power transformers, and power factor correction.
Courses that cover the operation of different rotating machines, such as permanent-magnet dc
motors, induction machines, and synchronous machines.
Optional courses that cover less common machines, such as conventional dc machines, universal
motors, and single-phase induction motors.
• The course curriculum of the Electric Power Technology Training Program is highly flexible and allows a
multitude of different customized training solutions.
• The courseware includes student manuals and instructor guides with all the theory required to perform
the hands-on experiments.
• All workstations, modules, and components are very sturdy to ensure a prolonged service life in a
demanding environment such as a training laboratory.
• The modular design approach of the training equipment allows a large variety of courses to be
performed using a small number of modules, without unnecessary duplication of equipment.
• All electrical components can be interconnected without electric shock hazard since all live parts of the
connection leads are concealed and insulated.
• All electrical symbols representing the components used in a laboratory exercise are clearly silk-
screened on the front panel of the modules.
• The training system includes two highly versatile USB peripherals:
Four-Quadrant Dynamometer/Power Supply, Model 8960-2. This module is used as a dc and ac power
source. it can also be mechanically coupled to all rotating machines to operate as a prime mover or
brake.
© Festo Didactic 92
Electric Power Technology Training Systems, LabVolt Series
Data Acquisition and Control Interface, Model 9063. This module gives access to a large variety of
computer-based measuring instruments via the LVDAC-EMS software.
• Software upgrades for LVDAC-EMS and firmware upgrades for the Four-Quadrant Dynamometer/Power
Supply and Data Acquisition and Control Interface are available for download free of charge on the
Festo Didactic website.
List of Equipment
Model
Qty Description
number
1 Permanent Magnet DC Motor (Instructor Guide) _____________________________________ 8113732 (8113732)
1 Permanent Magnet DC Motor (Student Manual) _____________________________________ 8113734 (8113734)
1 Power Factor Correction (Student Manual) __________________________________________ 579334 (20116-00)
1 Power Factor Correction (Instructor Guide) __________________________________________ 579335 (2011610)
1 DC Power Circuits (Student Manual) _______________________________________________ 579339 (86350-00)
1 DC Power Circuits (Instructor Guide) _______________________________________________ 579341 (8635010)
1 Single-Phase AC Power Circuits (Student Manual) ____________________________________ 579366 (86358-00)
1 Single-Phase AC Power Circuits (Instructor Guide) ____________________________________ 579368 (8635810)
1 Three-Phase AC Power Circuits (Student Manual) ____________________________________ 579374 (86360-00)
1 Three-Phase AC Power Circuits (Instructor Guide) ____________________________________ 579378 (8636010)
1 Three-Phase Rotating Machines (Student Manual) ___________________________________ 579407 (86364-00)
1 Three-Phase Rotating Machines (Instructor Guide) ___________________________________ 579409 (8636410)
1 Single-Phase Power Transformer (Student Manual) ___________________________________ 579437 (86377-00)
1 Single-Phase Power Transformer (Instructor Guide) ___________________________________ 579439 (8637710)
1 Three-Phase Transformer Banks (Student Manual) ___________________________________ 579448 (86379-00)
1 Three-Phase Transformer Banks (Instructor Guide) ___________________________________ 579451 (8637910)
1 Tabletop Workstation ____________________________________________________________ 579484 (813420)
1 Permanent Magnet DC Motor _____________________________________________________ 8114247 (821310)
1 Four-Pole Squirrel Cage Motor _____________________________________________________ 586267 (822120)
1 Three-Phase Synchronous Motor/Generator _________________________________________ 579502 (824120)
1 Resistive Load __________________________________________________________________ 763359 (8311-00)
1 Inductive Load __________________________________________________________________ 763362 (8321-00)
1 Capacitive Load _________________________________________________________________ 763366 (8331-00)
1 Three-Phase Transformer Bank ____________________________________________________ 579559 (834840)
1 Transformer ____________________________________________________________________ 763371 (8353-00)
1 Synchronizing Module / Three-Phase Contactor _______________________________________ 579576 (8621A0)
1 Lead-Acid Battery Pack ___________________________________________________________ 579591 (880210)
1 Three-Phase Power Supply ________________________________________________________ 579612 (8823-00)
1 Timing Belt _____________________________________________________________________ 579637 (8942-00)
1 Connection Lead Set ______________________________________________________________ 579638 (8951L0)
1 Four-Quadrant Dynamometer / Power Supply with Manual and Computer-Based Control _____ 579648 (8960C0)
1 Data Acquisition and Control Interface ______________________________________________ 579692 (9063G0)
1 AC 24 V Wall Mount Power Supply _________________________________________________ 579696 (3000420)
93 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
List of Manuals
Manual
Description
number
Power Factor Correction (Workbook) ___________________________________________________579334 (20116-00)
Power Factor Correction (Workbook (Instructor)) _________________________________________ 579335 (2011610)
DC Power Circuits (Workbook) ________________________________________________________579339 (86350-00)
DC Power Circuits (Workbook (Instructor)) ______________________________________________ 579341 (8635010)
Single-Phase AC Power Circuits (Workbook) _____________________________________________579366 (86358-00)
Single-Phase AC Power Circuits (Workbook (Instructor)) ___________________________________ 579368 (8635810)
Three-Phase AC Power Circuits (Workbook) _____________________________________________579374 (86360-00)
Three-Phase AC Power Circuits (Workbook (Instructor)) ___________________________________ 579378 (8636010)
Three-Phase Rotating Machines (Workbook) ___________________________________________ 579407 (86364-00)
Three-Phase Rotating Machines (Workbook (Instructor)) __________________________________ 579409 (8636410)
Single-Phase Power Transformers (Workbook) ___________________________________________579437 (86377-00)
Single-Phase Power Transformers (Workbook (Instructor)) _________________________________ 579439 (8637710)
Three-Phase Transformer Banks (Workbook) ___________________________________________ 579448 (86379-00)
Three-Phase Transformer Banks (Workbook (Instructor)) __________________________________ 579451 (8637910)
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
Permanent Magnet DC Machine (Workbook (Instructor)) __________________________________ 8113732 (8113732)
Permanent Magnet DC Machine (Workbook) ___________________________________________ 8113734 (8113734)
© Festo Didactic 94
Electric Power Technology Training Systems, LabVolt Series
95 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Level 2
Model
Qty Description
number
1 DC Motor/Generator ___________________________________________________________ 579759 (8211-00) 64
1 Capacitor-Start Motor __________________________________________________________ 579767 (8251-00) 65
1 Universal Motor _______________________________________________________________ 579774 (8254-00) 66
Optional Equipment
Model
Qty Description
number
1 Full-Size Blank EMS Module _____________________________________________________ 579757 (8160-00) 67
1 Half-Size Blank EMS Module ____________________________________________________ 579758 (8161-00) 68
1 Wind Turbine Generator/Controller _______________________________________________ 579487 (8216-00) 69
1 Variable Three-Phase Power Supply _______________________________________________ 579603 (882120) 70
1 Multimeters Module ____________________________________________________________ 586888 (8946A0) 71
63 The data acquisition already includes this function and many more, but the DC Circuits manual references using multimeters.
64 Requires the variable power supply.
65 Requires the variable power supply.
66 Requires the variable power supply.
67 To mount your own devices.
68 To mount your own devices.
69 Optional equipment only necessary for a section of one exercise
70 Can replace the fixed power supply and the 24V adapter.
71 Can replace the Digital Multimeters.
© Festo Didactic 96
Electric Power Technology Training Systems, LabVolt Series
Software
Model
Qty Description
number
1 Software Development Kit (SDK) __________________________________________________ 581441 (896870) 72
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 1 User Online, 1 year ____ 586971 (8972-00) 73
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 5 Users Online, 1 year ____ 586974 (8972A0) 74
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 10 Users Online, 1 year ___ 586977 (8972B0) 75
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 15 Users Online, 1 year ___ 586980 (8972C0) 76
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 20 Users Online, 1 year ___ 586983 (8972D0) 77
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 25 Users Online, 1 year ___ 586986 (8972E0) 78
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 30 Users Online, 1 year ___ 586989 (8972F0) 79
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 25 Users Online, 1 year ___ 586992 (8972G0) 80
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 40 Users Online, 1 year ___ 586995 (8972H0) 81
1 SCADA for LVDAC-EMS ________________________________________________________ 8094377 (8973-00) 82
1 Software Development Kit (SDK) __________________________________________________ 581459 (906990) 83
Workstation
Model
Qty Description
number
1 Mobile Workstation _____________________________________________________________ 579755 (811020) 84
1 Storage Shelves _________________________________________________________________ 579756 (815010)
1 Dust Cover for Workstations _______________________________________________________ 587004 (8991-00)
1 Dust Cover for EMS Storage Cabinet ________________________________________________ 587006 (8992-00)
1 Three-Phase Power Receptable - NEMA L22-20 ______________________________________ 768193 (24183-00)
1 Three-Phase Power Receptable - NEMA L21-20R _____________________________________ 768288 (24582-00)
1 Three-Phase Power Receptacle - 5-Pin Round ________________________________________ 775548 (35153-00)
1 External Shelf for the Mobile Workstation _________________________________________ 581465 (36653-00) 85
1 Mounting Stand with Articulating Arm ____________________________________________ 8108710 (36653A0) 86
1 Mobile Base _________________________________________________________________ 587518 (88863-00) 87
System Specifications
Parameter Value
System Requirements
Maximum Current 10 A
97 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
Parameter Value
Typical Current 1.5 A per student group
3 phases (120/208 V – 60 Hz), star (wye) configuration including neutral and ground wires, protected by a 20 A
AC Power Network Installation
circuit breaker
AC Power Network Connector NEMA L21-20
A currently available personal computer with USB 2.0 ports, running under one of the following operating
Computer Requirements
systems: Windows® 7 or Windows® 8.
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 900 x 930 x 530 mm (35.4 x 36.6 x 20.9 in)
Net Weight 205 kg (451 lb)
EMS Modules
Full-Size Dimensions (H x W x D) 308 x 287 x 440 mm (12.1 x 11.3 x 17.3 in)
Half-Size Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
• DC Power Electronics
• Single-Phase AC Power Electronics
• Three-Phase AC Power Electronics
• Thyristor Power Electronics
These courses introduce the student to the most common power electronic components (power diode, thyristor,
and power transistor) as well as to many power electronic devices used in numerous applications today (power
diode single-phase and three-phase rectifiers, choppers, single-phase and three-phase inverters, thyristor
single-phase and three-phase bridges, solid-state relays or SSRs, and thyristor ac power controllers). Training
continues with the following three courses which deal with common industrial applications using power
electronics:
• DC Motor Drives
• Three-Phase Motor Drives
• Three-Phase Induction Motor Starters
The following two courses from the Electric Power Technology Training Program, can be optionally added to the
Power Electronics Training System to enhance student training in power electronic applications:
© Festo Didactic 98
Electric Power Technology Training Systems, LabVolt Series
These two courses familiarize the student with the use of hydropower to produce electrical power using
synchronous generators, as well as with the transmission of large amounts of electrical power using high-
voltage, direct-current (HVDC) lines, two advanced applications using thyristor power electronics.
The Power Electronics Training System is part of the Electric Power Technology Training Systems, Series 8010.
Each training system in Series 8010 is based on the Electric Power Technology Training Program and provides a
turn-key solution dealing with some aspects of the wide field of electrical energy. The exhaustive courseware
provided with each training system covers all the theory required to perform the laboratory exercises, while
review questions and unit tests allow students to test the knowledge they have gained.
The Electric Power Technology Training Program is highly modular in both courseware and hardware. Because of
this, courses and equipment from the program are available as required, either individually or in the context of a
specific training system. The program covers several different subjects in the field of electrical energy, such as
rotating machines, electrical power transmission, power electronics, home energy production from renewable
resources (wind and sunlight), large-scale electricity production from hydropower and wind power, smart-grid
technologies (SVC, STATCOM, HVDC transmission, etc.), storage of electrical energy in batteries, and drive
systems for small electric vehicles and cars.
99 © Festo Didactic
Electric Power Technology Training Systems, LabVolt Series
The above chart shows all courses in the Electric Power Technology Training Program. Blue boxes highlight courses included in the
training system covered in this datasheet, while dark grey boxes, if any, highlight courses that can be optionally added to this
training system.
Courseware
Each course in the training system
includes a full-color student manual
providing all the theoretical matter
required, guided lab-exercise
procedures to be performed with the
training equipment, and review
questions that test the knowledge
gained by the student. Whenever
possible, each course is built to bring
the student to actual applications as
soon as possible. A full-color
instructor guide providing all lab
results and answers to questions is
© Festo Didactic 100
also included with each course.
Electric Power Technology Training Systems, LabVolt Series
• The training system teaches the principles of dc and ac power electronics. To this end, students follow a
complete curriculum that includes these topics:
Courses that cover the operation of various power electronics devices, both dc and ac, as well as
single-phase and three-phase.
Courses that cover a variety of common power electronics applications, such as dc motor drives,
three-phase motor drives, and three-phase induction motor starters.
Optional courses that cover advanced applications of power electronics, such as hydropower
electricity generation, and HVDC transmission systems.
• All control of power electronics devices is computerized via the LVDAC-EMS software, allowing for user-
friendly operation, high configurability, and ease of monitoring.
• Video presentations of several power electronics control functions used in the training system are
available on Youtube.
• The course curriculum of the Electric Power Technology Training Program is highly flexible and allows a
multitude of different customized training solutions.
• The courseware includes student manuals and instructor guides with all the theory required to perform
the hands-on experiments.
• All workstations, modules, and components are sturdy and protected against electrical damage to
ensure a prolonged service life in a demanding environment such as a training laboratory.
• The modular design approach of the training equipment allows a large variety of courses to be
performed using a small number of modules, without unnecessary duplication of equipment.
• All electrical components can be interconnected without electric shock hazard since all live parts of the
connection leads are concealed and insulated.
• All electrical symbols representing the components used in a laboratory exercise are clearly silk-
screened on the front panel of the modules.
• The training system includes two highly versatile USB peripherals:
Four-Quadrant Dynamometer/Power Supply, Model 8960-2. This module is used as a dc power
source and a battery charger/discharger with a large variety of configurable parameters. It can also
be used as an overnight battery float charger.
Data Acquisition and Control Interface, Model 9063. This module gives access to a large variety of
computer-based measuring instruments and is used to control the various dc power electronics
devices. All functions are implemented via the LVDAC-EMS software.
• The training system also includes three highly versatile power electronics modules controlled using the
Data Acquisition and Control Interface:
IGBT Chopper/Inverter, Model 8837-B. This module is used to implement various types of choppers
and inverters.
Power Thyristors, Model 8841. This module is used to implement various thyristor-based devices
(e.g., bridges, ac power controllres, solid-state relays)
Rectifier and Filtering Capacitors, Model 8842-A. This module is used to implement various types of
power diode rectifiers.
• Software upgrades for LVDAC-EMS and firmware upgrades for the Four-Quadrant Dynamometer/Power
Supply and Data Acquisition and Control Interface are available for download free of charge on the
Festo Didactic website.
List of Equipment
Model
Qty Description
number
1 DC Motor Drives (Instructor Guide) _______________________________________________ 8113740 (8113740)
1 DC Motor Drives (Student Manual) _______________________________________________ 8113742 (8113742)
1 DC Power Electronics (Student Manual) ____________________________________________ 579358 (86356-00)
1 DC Power Electronics (Instructor Guide) ____________________________________________ 579360 (8635610)
1 Single-Phase AC Power Electronics (Student Manual) _________________________________ 579370 (86359-00)
1 Single-Phase AC Power Electronics (Instructor Guide) _________________________________ 579372 (8635910)
1 Three-Phase AC Power Electronics (Student Manual) __________________________________ 579393 (86362-00)
1 Three-Phase AC Power Electronics (Instructor Guide) _________________________________ 579395 (8636210)
1 Thyristor Power Electronics (Student Manual) _______________________________________ 579402 (86363-00)
1 Thyristor Power Electronics (Instructor Guide) _______________________________________ 579403 (8636310)
1 Three-Phase Motor Drives (Student Manual) ________________________________________ 579426 (86368-00)
1 Three-Phase Motor Drives (Instructor Guide) ________________________________________ 579427 (8636810)
1 Three-Phase Motor Starters (Student Manual) _______________________________________ 579462 (88197-00)
Model
Qty Description
number
1 Three-Phase Motor Starters (Instructor Guide) _______________________________________ 579463 (8819710)
1 Tabletop Workstation ____________________________________________________________ 579484 (813420)
1 Permanent Magnet DC Motor _____________________________________________________ 8114247 (821310)
1 Four-Pole Squirrel Cage Motor _____________________________________________________ 586267 (822120)
1 Resistive Load __________________________________________________________________ 763359 (8311-00)
1 Filtering Inductors/Capacitors _____________________________________________________ 579523 (8325A0)
1 Three-Phase Filter _______________________________________________________________ 579529 (8326-00)
1 Capacitive Load _________________________________________________________________ 763366 (8331-00)
1 Three-Phase Transformer Bank ____________________________________________________ 579559 (834840)
1 Synchronizing Module / Three-Phase Contactor _______________________________________ 579576 (8621A0)
1 Lead-Acid Battery Pack ___________________________________________________________ 579591 (880210)
1 Three-Phase Power Supply ________________________________________________________ 579612 (8823-00)
1 IGBT Chopper/Inverter ___________________________________________________________ 579623 (8837B0)
1 Power Thyristors ________________________________________________________________ 763376 (884120)
1 Rectifier and Filtering Capacitors ___________________________________________________ 579630 (8842A0)
1 Timing Belt _____________________________________________________________________ 579637 (8942-00)
1 Connection Lead Set ______________________________________________________________ 579638 (8951L0)
1 Four-Quadrant Dynamometer/Power Supply __________________________________________ 579662 (8960E0)
1 Data Acquisition and Control Interface ______________________________________________ 579686 (9063D0)
1 AC 24 V Wall Mount Power Supply _________________________________________________ 579696 (3000420)
List of Manuals
Manual
Description
number
DC Power Electronics (Workbook) _____________________________________________________579358 (86356-00)
DC Power Electronics (Workbook (Instructor)) ___________________________________________ 579360 (8635610)
Single-Phase AC Power Electronics (Workbook) __________________________________________579370 (86359-00)
Single-Phase AC Power Electronics (Workbook (Instructor)) ________________________________ 579372 (8635910)
Three-Phase AC Power Electronics (Workbook) __________________________________________579393 (86362-00)
Three-Phase AC Power Electronics (Workbook (Instructor)) _________________________________ 579395 (8636210)
Thyristor Power Electronics (Workbook) ________________________________________________579402 (86363-00)
Thyristor Power Electronics (Workbook (Instructor)) ______________________________________ 579403 (8636310)
Manual
Description
number
Three-Phase Motor Drives (Workbook) _________________________________________________579426 (86368-00)
Three-Phase Motor Drives (Workbook (Instructor)) _______________________________________ 579427 (8636810)
Three-Phase Induction Motor Starters (Workbook) _______________________________________579462 (88197-00)
Three-Phase Induction Motor Starters (Workbook (Instructor)) _____________________________ 579463 (8819710)
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
DC Motor Drives (Workbook (Instructor)) ______________________________________________ 8113740 (8113740)
DC Motor Drives (Workbook) ________________________________________________________ 8113742 (8113742)
Level 2
Model
Qty Description
number
1 Three-Phase Synchronous Motor/Generator _________________________________________ 579502 (824120)
1 Inductive Load __________________________________________________________________ 763362 (8321-00)
1 Three-Phase Transmission Line ____________________________________________________ 579535 (8329-00)
1 Three-Phase Regulating Autotransformer ____________________________________________ 763369 (8349-00)
Optional Equipment
Model
Qty Description
number
1 Full-Size Blank EMS Module _____________________________________________________ 579757 (8160-00) 89
1 Half-Size Blank EMS Module ____________________________________________________ 579758 (8161-00) 90
1 Three-Phase Transformer Bank ____________________________________________________ 579559 (834840)
1 AC Power Network Interface _____________________________________________________ 579581 (8622-00) 91
1 Solar Panel Test Bench _________________________________________________________ 579594 (8805-00) 92
1 Variable Three-Phase Power Supply _______________________________________________ 579603 (882120) 93
1 Multimeters Module ____________________________________________________________ 586888 (8946A0) 94
Software
Model
Qty Description
number
1 Software Development Kit (SDK) __________________________________________________ 581441 (896870) 95
88 The data acquisition already includes this function and many more, but the DC Circuits manual references using multimeters.
89 To mount your own devices.
90 To mount your own devices.
91 Optional equipment only necessary for a section of one exercise.
92 Optional equipment only necessary for a section of one exercise.
93 Can replace the fixed power supply and the 24V adapter.
94 Can replace the Digital Multimeters.
95 Additional firmware for the Four-Quadrant Dynamometer/Power Supply.
Model
Qty Description
number
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 1 User Online, 1 year ____ 586971 (8972-00) 96
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 5 Users Online, 1 year ____ 586974 (8972A0) 97
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 10 Users Online, 1 year ___ 586977 (8972B0) 98
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 15 Users Online, 1 year ___ 586980 (8972C0) 99
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 20 Users Online, 1 year __ 586983 (8972D0) 100
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 25 Users Online, 1 year __ 586986 (8972E0) 101
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 30 Users Online, 1 year __ 586989 (8972F0) 102
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 25 Users Online, 1 year __ 586992 (8972G0) 103
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 40 Users Online, 1 year __ 586995 (8972H0) 104
1 SCADA for LVDAC-EMS ________________________________________________________ 8094377 (8973-00) 105
1 Software Development Kit (SDK) _________________________________________________ 581459 (906990) 106
Workstation
Model
Qty Description
number
1 Mobile Workstation ____________________________________________________________ 579755 (811020) 107
1 Storage Shelves _________________________________________________________________ 579756 (815010)
1 Dust Cover for Workstations _______________________________________________________ 587004 (8991-00)
1 Dust Cover for EMS Storage Cabinet ________________________________________________ 587006 (8992-00)
1 Three-Phase Power Receptable - NEMA L22-20 ______________________________________ 768193 (24183-00)
1 Three-Phase Power Receptable - NEMA L21-20R _____________________________________ 768288 (24582-00)
1 Three-Phase Power Receptacle - 5-Pin Round ________________________________________ 775548 (35153-00)
1 External Shelf for the Mobile Workstation _________________________________________ 581465 (36653-00) 108
1 Mounting Stand with Articulating Arm ___________________________________________ 8108710 (36653A0) 109
1 Mobile Base _________________________________________________________________ 587518 (88863-00) 110
96 Simulation software that covers DC, single-phase and 3 phase circuits as well as motors and generators and transmission lines. Doesn't cover
power electronics.
97 Simulation software that covers DC, single-phase and 3 phase circuits as well as motors and generators and transmission lines. Doesn't cover
power electronics.
98 Simulation software that covers DC, single-phase and 3 phase circuits as well as motors and generators and transmission lines. Doesn't cover
power electronics.
99 Simulation software that covers DC, single-phase and 3 phase circuits as well as motors and generators and transmission lines. Doesn't cover
power electronics.
100 Simulation software that covers DC, single-phase and 3 phase circuits as well as motors and generators and transmission lines. Doesn't cover
power electronics.
101 Simulation software that covers DC, single-phase and 3 phase circuits as well as motors and generators and transmission lines. Doesn't cover
power electronics.
102 Simulation software that covers DC, single-phase and 3 phase circuits as well as motors and generators and transmission lines. Doesn't cover
power electronics.
103 Simulation software that covers DC, single-phase and 3 phase circuits as well as motors and generators and transmission lines. Doesn't cover
power electronics.
104 Simulation software that covers DC, single-phase and 3 phase circuits as well as motors and generators and transmission lines. Doesn't cover
power electronics.
105 Software allowing the monitoring of up to 5 Stations through OPC.
106 Additional firmware for the Data Acquisition.
107 Can replace the Tabletop Workstation included in the system.
108 External Shelf for the Mobile Workstation, to put papers, laptop, keyboard, mouse, etc.
109 To mount your own monitor or touch screen.
110 Mobile Base Plate.
System Specifications
Parameter Value
Sytem Requirements
Maximum Current 10 A
Typical Current 1.5 A per student group
3 phases (120/208 V – 60 Hz), star (wye) configuration including neutral and ground wires, protected by a 20 A
AC Power Network Installation
circuit breaker
AC Power Network Connector NEMA L21-20
A currently available personal computer with USB 2.0 ports, running under one of the following operating
Computer Requirements
systems: Windows® 7 or Windows® 8.
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 900 x 930 x 530 mm (35.4 x 36.6 x 20.9 in)
Net Weight 191 kg (420 lb)
EMS Modules
Full-Size Dimensions (H x W x D) 308 x 287 x 440 mm (12.1 x 11.3 x 17.3 in)
Half-Size Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
These courses introduce students to the fundamentals of three-phase ac power circuits (wye and delta
configurations, three-phase ac power measurement, phase sequence), as well as to the operating
characteristics of three-phase transformer banks, which are an essential component in ac power transmission
systems. Training continues with the main course of the AC Power Transmission Training System:
• AC Transmission Lines
This course is the core of the training system and introduces students to the characteristics and behavior of
high-voltage ac transmission lines, as well as to the voltage compensation of these lines using switched shunt
compensation (SSC). It covers a multitude of topics related to high-voltage transmission lines, such as voltage
regulation characteristics, characteristic impedance, natural load, corrected PI equivalent circuit, power voltage
curve, line length, and active power transmission.
The following four courses from the Electric Power Technology Training Program can be optionally added to the
AC Power Transmission Training System to provide students with the basic knowledge of electric power
technology required to study ac power transmission systems:
• DC Power Circuits
• Single-Phase AC Power Circuits
These four courses familiarize the student with the fundamentals of dc power circuits and single-phase ac
power circuits, as well as with the operating characteristics of single-phase power transformers and three-phase
rotating machines (notably the three-phase synchronous generator).
The AC Power Transmission Training System is part of the Electric Power Technology Training Systems, Series
8010. Each training system in Series 8010 is based on the Electric Power Technology Training Program and
provides a turn-key solution dealing with some aspects of the wide field of electrical energy. The exhaustive
courseware provided with each training system covers all the theory required to perform the laboratory
exercises, while review questions and unit tests allow students to test the knowledge they have gained.
The Electric Power Technology Training Program is highly modular in both courseware and hardware. Because of
this, courses and equipment from the program are available as required, either individually or in the context of a
specific training system. The program covers several different subjects in the field of electrical energy, such as
rotating machines, electrical power transmission, power electronics, home energy production from renewable
resources (wind and sunlight), large-scale electricity production from hydropower and wind power, smart-grid
technologies (SVC, STATCOM, HVDC transmission, etc.), storage of electrical energy in batteries, and drive
systems for small electric vehicles and cars.
The above chart shows all courses in the Electric Power Technology Training Program. Blue boxes highlight courses included in the
training system covered in this datasheet, while dark grey boxes, if any, highlight courses that can be optionally added to this
training system.
Courseware
Each course in the training system
includes a full-color student manual
providing all the theoretical matter
required, guided lab-exercise
procedures to be performed with the
training equipment, and review
questions that test the knowledge
gained by the student. Whenever
possible, each course is built to bring
the student to actual applications as
soon as possible. A full-color
instructor guide providing all lab
results and answers to questions is
also included with each course.
• The training system teaches the principles of ac power transmission directly in the laboratory. To this
end, students follow a complete curriculum that includes these topics:
An introduction to three-phase ac power circuits and three-phase transformer banks, necessary
concepts in the study of ac power transmission.
A complete course that covers extensively the principles, characteristics, and operation of ac
transmission lines.
Optional courses that provide the basic knowledge of electric power technology required to study ac
power transmission.
• The course curriculum of the Electric Power Technology Training Program is highly flexible and allows a
multitude of different customized training solutions.
• The courseware includes student manuals and instructor guides with all the theory required to perform
the hands-on experiments.
• All workstations, modules, and components are sturdy and protected against electrical damage to
ensure a prolonged service life in a demanding environment such as a training laboratory.
• The modular design approach of the training equipment allows a large variety of courses to be
performed using a small number of modules, without unnecessary duplication of equipment.
• All electrical components can be interconnected without electric shock hazard since all live parts of the
connection leads are concealed and insulated.
• All electrical symbols representing the components used in a laboratory exercise are clearly silk-
screened on the front panel of the modules.
• The training system includes a highly versatile USB peripheral:
Data Acquisition and Control Interface, Model 9063. This module gives access to a large variety of
computer-based measuring instruments via the LVDAC-EMS software.
• Software upgrades for LVDAC-EMS and firmware upgrades for the Data Acquisition and Control
Interface are available for download free of charge on the Festo Didactic website.
List of Equipment
Model
Qty Description
number
1 AC Transmission Line (Student Manual) ____________________________________________ 580204 (20521-00)
1 AC Transmission Line (Instructor Guide) ____________________________________________ 580205 (2052110)
1 Three-Phase AC Power Circuits (Student Manual) ____________________________________ 579374 (86360-00)
1 Three-Phase AC Power Circuits (Instructor Guide) ____________________________________ 579378 (8636010)
1 Three-Phase Transformer Banks (Student Manual) ___________________________________ 579448 (86379-00)
1 Three-Phase Transformer Banks (Instructor Guide) ___________________________________ 579451 (8637910)
1 Tabletop Workstation ____________________________________________________________ 579484 (813420)
1 Resistive Load __________________________________________________________________ 763359 (8311-00)
2 Inductive Load __________________________________________________________________ 763362 (8321-00)
1 Three-Phase Transmission Line ____________________________________________________ 579535 (8329-00)
3 Capacitive Load _________________________________________________________________ 763366 (8331-00)
1 Three-Phase Transformer Bank ____________________________________________________ 579559 (834840)
1 Three-Phase Regulating Autotransformer ____________________________________________ 763369 (8349-00)
1 Three-Phase Power Supply ________________________________________________________ 579612 (8823-00)
1 Connection Lead Set ______________________________________________________________ 579638 (8951L0)
1 Connection Lead Set _____________________________________________________________ 579639 (8951N0)
1 Data Acquisition and Control Interface ______________________________________________ 579680 (9063B0)
1 AC 24 V Wall Mount Power Supply _________________________________________________ 579696 (3000420)
List of Manuals
Manual
Description
number
Three-Phase AC Power Circuits (Workbook) _____________________________________________579374 (86360-00)
Three-Phase AC Power Circuits (Workbook (Instructor)) ___________________________________ 579378 (8636010)
Three-Phase Transformer Banks (Workbook) ___________________________________________ 579448 (86379-00)
Three-Phase Transformer Banks (Workbook (Instructor)) __________________________________ 579451 (8637910)
AC Transmission Lines (Workbook) ____________________________________________________580204 (20521-00)
AC Transmission Lines (Workbook (Instructor)) __________________________________________ 580205 (2052110)
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
Level 2
Model
Qty Description
number
1 Wind Turbine Generator/Controller _______________________________________________ 579487 (8216-00) 112
1 Four-Pole Squirrel Cage Motor _____________________________________________________ 586267 (822120)
1 Three-Phase Synchronous Motor/Generator _________________________________________ 579502 (824120)
1 Transformer ____________________________________________________________________ 763371 (8353-00)
1 Synchronizing Module / Three-Phase Contactor _______________________________________ 579576 (8621A0)
1 Four-Quadrant Dynamometer / Power Supply with Manual and Computer-Based Control _____ 579648 (8960C0)
Optional Equipment
Model
Qty Description
number
1 Full-Size Blank EMS Module _____________________________________________________ 579757 (8160-00) 113
1 Half-Size Blank EMS Module ____________________________________________________ 579758 (8161-00) 114
1 Variable Three-Phase Power Supply ______________________________________________ 579603 (882120) 115
1 Multimeters Module ___________________________________________________________ 586888 (8946A0) 116
Software
Model
Qty Description
number
1 Software Development Kit (SDK) _________________________________________________ 581441 (896870) 117
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 1 User Online, 1 year ____ 586971 (8972-00) 118
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 5 Users Online, 1 year ___ 586974 (8972A0) 119
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 10 Users Online, 1 year __ 586977 (8972B0) 120
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 15 Users Online, 1 year __ 586980 (8972C0) 121
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 20 Users Online, 1 year __ 586983 (8972D0) 122
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 25 Users Online, 1 year __ 586986 (8972E0) 123
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 30 Users Online, 1 year __ 586989 (8972F0) 124
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 25 Users Online, 1 year __ 586992 (8972G0) 125
111 The data acquisition already includes this function and many more, but the DC Circuits manual references using multimeters.
112 Optional equipment only necessary for a section of one exercise.
113 To mount your own devices.
114 To mount your own devices.
115 Can replace the fixed power supply and the 24V adapter.
116 Can replace the Digital Multimeters.
117 Additional firmware for the Four-Quadrant Dynamometer/Power Supply.
118 Simulation software that covers these topics and more.
119 Simulation software that covers these topics and more.
120 Simulation software that covers these topics and more.
121 Simulation software that covers these topics and more.
122 Simulation software that covers these topics and more.
123 Simulation software that covers these topics and more.
124 Simulation software that covers these topics and more.
125 Simulation software that covers these topics and more.
Model
Qty Description
number
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 40 Users Online, 1 year __ 586995 (8972H0) 126
1 SCADA for LVDAC-EMS ________________________________________________________ 8094377 (8973-00) 127
1 Software Development Kit (SDK) _________________________________________________ 581459 (906990) 128
Workstation
Model
Qty Description
number
1 Mobile Workstation ____________________________________________________________ 579755 (811020) 129
1 Storage Shelves _________________________________________________________________ 579756 (815010)
1 Dust Cover for Workstations _______________________________________________________ 587004 (8991-00)
1 Dust Cover for EMS Storage Cabinet ________________________________________________ 587006 (8992-00)
1 Three-Phase Power Receptable - NEMA L22-20 ______________________________________ 768193 (24183-00)
1 Three-Phase Power Receptable - NEMA L21-20R _____________________________________ 768288 (24582-00)
1 Three-Phase Power Receptacle - 5-Pin Round ________________________________________ 775548 (35153-00)
1 External Shelf for the Mobile Workstation _________________________________________ 581465 (36653-00) 130
1 Mounting Stand with Articulating Arm ___________________________________________ 8108710 (36653A0) 131
1 Mobile Base _________________________________________________________________ 587518 (88863-00) 132
These courses introduce students to the fundamentals of SVCs, STATCOMs, and HVDC transmission systems.
Students learn that SVCs and STATCOMs, which are examples of flexible ac transmission systems (FACTS), can
be used in conjunction with HVDC transmission systems to greatly enhance the controllability and power
transfer capability of a power network and are thus essential tools to the implementation of a smart grid. These
courses also allow students to experiment with actual SVCs, STATCOMs, and HVDC transmission systems
implemented with power electronics modules.
The Smart Grid Technologies Training System is part of the Electric Power Technology Training Systems, Series
8010. Each training system in Series 8010 is based on the Electric Power Technology Training Program and
provides a turn-key solution dealing with some aspects of the wide field of electrical energy. The exhaustive
courseware provided with each training system covers all the theory required to perform the laboratory
exercises, while review questions and unit tests allow students to test the knowledge they have gained.
The Electric Power Technology Training Program is highly modular in both courseware and hardware. Because of
this, courses and equipment from the program are available as required, either individually or in the context of a
specific training system. The program covers several different subjects in the field of electrical energy, such as
rotating machines, electrical power transmission, power electronics, home energy production from renewable
resources (wind and sunlight), large-scale electricity production from hydropower and wind power, smart-grid
technologies (SVC, STATCOM, HVDC transmission, etc.), storage of electrical energy in batteries, and drive
systems for small electric vehicles and cars.
The above chart shows all courses in the Electric Power Technology Training Program. Blue boxes highlight courses included in the
training system covered in this datasheet, while dark grey boxes, if any, highlight courses that can be optionally added to this
training system.
Courseware
Each course in the training system
includes a full-color student manual
providing all the theoretical matter
required, guided lab-exercise
procedures to be performed with the
training equipment, and review
questions that test the knowledge
gained by the student. Whenever
possible, each course is built to bring
the student to actual applications as
soon as possible. A full-color
instructor guide providing all lab
results and answers to questions is
© Festo Didactic 116
also included with each course.
Electric Power Technology Training Systems, LabVolt Series
• The training system teaches the principles behind certain key technologies allowing the
implementation of a smart grid. These technologies include home energy production, SVCs, STATCOMs,
and HVDC transmission systems.
• Realistic control functions implemented using the Data Acquisition and Control Interface via the LVDAC-
EMS software allow the implementation of complex devices such as an SVC and a STATCOM directly in
the laboratory.
• The course curriculum of the Electric Power Technology Training Program is highly flexible and allows a
multitude of different customized training solutions.
• The courseware includes student manuals and instructor guides with all the theory required to perform
the hands-on experiments.
• All workstations, modules, and components are sturdy and protected against electrical damage to
ensure a prolonged service life in a demanding environment such as a training laboratory.
• The modular design approach of the training equipment allows a large variety of courses to be
performed using a small number of modules, without unnecessary duplication of equipment.
• All electrical components can be interconnected without electric shock hazard since all live parts of the
connection leads are concealed and insulated.
• All electrical symbols representing the components used in a laboratory exercise are clearly silk-
screened on the front panel of the modules.
• The training system includes two highly versatile USB peripherals:
Four-Quadrant Dynamometer/Power Supply, Model 8960-2. This module is used as a solar panel
emulator with a large variety of configurable parameters.
Data Acquisition and Control Interface, Model 9063. This module gives access to a large variety of
computer-based measuring instruments and is used to control the various power electronics devices
necessary for home energy production, as well as SVC, STATCOM, and HVDC implantation. All
functions are implemented via the LVDAC-EMS software.
• The training system also includes four highly versatile power electronics modules controlled using the
Data Acquisition and Control Interface:
SVC Reactors/Thyristor Switched Capacitors, Model 8334. This module is used to implement the TCR
and TSCs for SVC operation.
Insulated DC-to-DC Converter, Model 8835. This module is used to implement a solar/wind power
inverter with HF transformer topology.
+ IGBT Chopper/Inverter, Model 8837-B. This module is used to implement the solar/wind power
inverter for home energy production and the three-phase PWM rectifier/inverter for STATCOM
operation.
Power Thyristors, Model 8841. This module is used to implement the TCR and TSCs for SVC operation
and the thyristor converters for HVDC operation.
• Software upgrades for LVDAC-EMS and firmware upgrades for the Four-Quadrant Dynamometer/Power
Supply and Data Acquisition and Control Interface are available for download free of charge on the
Festo Didactic website.
List of Equipment
Model
Qty Description
number
1 Home Energy Production (Student Manual) _________________________________________ 579385 (86361-00)
1 Home Energy Production (Instructor Guide) _________________________________________ 579387 (8636110)
1 Static Var Compensators (SVC) (Student Manual) ____________________________________ 579431 (86370-00)
1 Static Var Compensators (SVC) (Instructor Guide) ____________________________________ 579432 (8637010)
1 Static Synchronous Compensator (STATCOM) (Student Manual) ________________________ 579433 (86371-00)
1 Static Synchronous Compensator (STATCOM) (Instructor Guide) ________________________ 579434 (8637110)
1 High-Voltage DC Transmission Systems (Student Manual) _____________________________ 579460 (86380-00)
1 High-Voltage DC Transmission Systems (Instructor Guide) _____________________________ 579461 (8638010)
1 Tabletop Workstation ____________________________________________________________ 579484 (813420)
1 Resistive Load __________________________________________________________________ 763359 (8311-00)
1 Inductive Load __________________________________________________________________ 763362 (8321-00)
1 Filtering Inductors/Capacitors _____________________________________________________ 579523 (8325A0)
1 Three-Phase Filter _______________________________________________________________ 579529 (8326-00)
1 Line Inductors __________________________________________________________________ 763364 (8326A0)
2 Three-Phase Transmission Line ____________________________________________________ 579535 (8329-00)
1 Capacitive Load _________________________________________________________________ 763366 (8331-00)
1 SVC Reactors / Thyristor-Switched Capacitors ________________________________________ 763368 (8334-00)
2 Three-Phase Transformer Bank ____________________________________________________ 579559 (834840)
2 Three-Phase Regulating Autotransformer ____________________________________________ 763369 (8349-00)
1 Transformer ____________________________________________________________________ 763371 (8353-00)
1 Three-Phase Transformer _________________________________________________________ 763373 (8354-00)
1 AC Power Network Interface _______________________________________________________ 579581 (8622-00)
1 Lead-Acid Battery Pack ___________________________________________________________ 579591 (880210)
1 Variable Three-Phase Power Supply ________________________________________________ 579603 (882120)
1 Insulated DC-to-DC Converter _____________________________________________________ 579618 (8835-00)
1 IGBT Chopper/Inverter ___________________________________________________________ 579623 (8837B0)
2 Power Thyristors ________________________________________________________________ 763376 (884120)
1 Connection Lead Set ______________________________________________________________ 579638 (8951L0)
1 Connection Lead Set _____________________________________________________________ 579639 (8951N0)
1 Four-Quadrant Dynamometer/Power Supply _________________________________________ 579674 (8960G0)
Model
Qty Description
number
1 Data Acquisition and Control Interface ______________________________________________ 579677 (9063-00)
1 Data Acquisition and Control Interface ______________________________________________ 579694 (9063H0)
List of Manuals
Manual
Description
number
Home Energy Production (Workbook) __________________________________________________579385 (86361-00)
Home Energy Production (Workbook (Instructor)) ________________________________________ 579387 (8636110)
Static Var Compensator (SVC) (Workbook) ______________________________________________579431 (86370-00)
Static Var Compensator (SVC) (Workbook (Instructor)) ____________________________________ 579432 (8637010)
Static Synchronous Compensator (STATCOM) (Workbook) _________________________________579433 (86371-00)
Static Synchronous Compensator (STATCOM) (Workbook (Instructor)) _______________________ 579434 (8637110)
HVDC Transmission Systems (Workbook) _______________________________________________579460 (86380-00)
HVDC Transmission Systems (Workbook (Instructor)) _____________________________________ 579461 (8638010)
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
Optional Equipment
Model
Qty Description
number
1 Full-Size Blank EMS Module _____________________________________________________ 579757 (8160-00) 134
1 Half-Size Blank EMS Module ____________________________________________________ 579758 (8161-00) 135
1 Wind Turbine Generator/Controller _______________________________________________ 579487 (8216-00) 136
1 Timing Belt ___________________________________________________________________ 579637 (8942-00) 137
1 Multimeters Module ___________________________________________________________ 586888 (8946A0) 138
1 Turbine Emulator Function Set ___________________________________________________ 579783 (896830) 139
Software
Model
Qty Description
number
1 Software Development Kit (SDK) _________________________________________________ 581441 (896870) 140
1 SCADA for LVDAC-EMS ________________________________________________________ 8094377 (8973-00) 141
1 Software Development Kit (SDK) _________________________________________________ 581459 (906990) 142
Workstation
Model
Qty Description
number
1 Mobile Workstation ____________________________________________________________ 579755 (811020) 143
1 Storage Shelves _________________________________________________________________ 579756 (815010)
1 Dust Cover for Workstations _______________________________________________________ 587004 (8991-00)
1 Dust Cover for EMS Storage Cabinet ________________________________________________ 587006 (8992-00)
133 The data acquisition already includes this function and many more, but the DC Circuits manual references using multimeters.
134 To mount your own devices.
135 To mount your own devices.
136 Optional equipment for "Home Energy Production"
137 Optional item for Home Energy Production topic
138 Can replace the Digital Multimeters.
139 Optional item for Home Energy Production topic
140 Additional firmware for the Four-Quadrant Dynamometer/Power Supply.
141 Software allowing the monitoring of up to 5 Stations through OPC.
142 Additional firmware for the Data Acquisition.
143 Can replace the Tabletop Workstation included in the system.
Model
Qty Description
number
1 Three-Phase Power Receptable - NEMA L22-20 ______________________________________ 768193 (24183-00)
1 Three-Phase Power Receptable - NEMA L21-20R _____________________________________ 768288 (24582-00)
1 Three-Phase Power Receptacle - 5-Pin Round ________________________________________ 775548 (35153-00)
1 External Shelf for the Mobile Workstation _________________________________________ 581465 (36653-00) 144
1 Mounting Stand with Articulating Arm ___________________________________________ 8108710 (36653A0) 145
1 Mobile Base _________________________________________________________________ 587518 (88863-00) 146
System Specifications
Parameter Value
Sytem Requirements
Maximum Current 15 A
Typical Current 1.5 A per student group
3 phases (120/208 V – 60 Hz), star (wye) configuration including neutral and ground wires, protected by a 20 A
AC Power Network Installation
circuit breaker
AC Power Network Connector NEMA L21-20
Computer Requirements
A currently available personal computer with USB 2.0 ports, running under one of the following operating
Computer Requirements
systems: Windows® 7 or Windows® 8.
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 900 x 930 x 530 mm (35.4 x 36.6 x 20.9 in)
Net Weight TBE
EMS Modules
Full-Size Dimensions (H x W x D) 308 x 287 x 440 mm (12.1 x 11.3 x 17.3 in)
Half-Size Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
144 External Shelf for the Mobile Workstation, to put papers, laptop, keyboard, mouse, etc.
145 To mount your own monitor or touch screen
146 Mobile Base Plate
The above chart shows all courses in the Electric Power Technology Training Program. Blue boxes highlight courses included in the
training system covered in this datasheet, while dark grey boxes, if any, highlight courses that can be optionally added to this
training system.
Courseware
Each course in the training system includes a full-color student manual providing all the theoretical matter
required, guided lab-exercise procedures to be performed with the training equipment, and review questions
that test the knowledge gained by the student. Whenever possible, each course is built to bring the student to
actual applications as soon as possible. A full-color instructor guide providing all lab results and answers to
questions is also included with each course.
• The training system teaches the principles of doubly-fed induction generators (DFIGs), including the
operation of three-phase wound-rotor induction machines, which are used to implement DFIGs.
• The course curriculum of the Electric Power Technology Training Program is highly flexible and allows a
multitude of different customized training solutions.
• The courseware includes student manuals and instructor guides with all the theory required to perform
the hands-on experiments.
• All workstations, modules, and components are sturdy and protected against electrical damage to
ensure a prolonged service life in a demanding environment such as a training laboratory.
• The modular design approach of the training equipment allows a large variety of courses to be
performed using a small number of modules, without unnecessary duplication of equipment.
• All electrical components can be interconnected without electric shock hazard since all live parts of the
connection leads are concealed and insulated.
• All electrical symbols representing the components used in a laboratory exercise are clearly silk-
screened on the front panel of the modules.
• The training system includes two highly versatile USB peripherals:
Four-Quadrant Dynamometer/Power Supply, Model 8960-2. This module can be mechanically
coupled to all rotating machines to operate as a prime mover or brake.
Data Acquisition and Control Interface, Model 9063. This module gives access to a large variety of
computer-based measuring instruments and is used to control the various dc power electronics
devices necessary to DFIG operation. All functions are implemented via the LVDAC-EMS software.
• The training system also includes two highly versatile power electronics modules controlled using the
Data Acquisition and Control Interface:
IGBT Chopper/Inverter, Model 8837-B. This module is used to implement the three-phase PWM
inverter for DFIG operation.
Rectifier and Filtering Capacitors, Model 8842-A. This module is used to implement the three-phase
rectifier for DFIG operation.
List of Equipment
Model
Qty Description
number
1 Three-Phase Wound Rotor Induction Machine (Student Manual) ________________________ 579421 (86367-00)
1 Three-Phase Wound Rotor Induction Machine (Instructor Guide) ________________________ 579422 (8636710)
1 Principles of Doubly-Fed Induction Generators (DFIG) (Student Manual) __________________ 579435 (86376-00)
1 Principles of Doubly-Fed Induction Generators (DFIG) (Instructor Guide) __________________ 579436 (8637610)
1 Tabletop Workstation ____________________________________________________________ 579484 (813420)
1 Three-Phase Wound-Rotor Induction Machine ________________________________________ 579497 (8231B0)
1 Resistive Load __________________________________________________________________ 763359 (8311-00)
1 Three-Phase Transformer Bank ____________________________________________________ 579559 (834840)
1 Three-Phase Power Supply ________________________________________________________ 579612 (8823-00)
1 IGBT Chopper/Inverter ___________________________________________________________ 579623 (8837B0)
1 Rectifier and Filtering Capacitors ___________________________________________________ 579630 (8842A0)
1 Timing Belt _____________________________________________________________________ 579637 (8942-00)
1 Connection Lead Set ______________________________________________________________ 579638 (8951L0)
1 Four-Quadrant Dynamometer / Power Supply with Manual and Computer-Based Control _____ 579648 (8960C0)
1 Data Acquisition and Control Interface ______________________________________________ 579683 (9063C0)
1 AC 24 V Wall Mount Power Supply _________________________________________________ 579696 (3000420)
List of Manuals
Manual
Description
number
Three-Phase Wound-Rotor Induction Machines (Workbook) ________________________________579421 (86367-00)
Three-Phase Wound-Rotor Induction Machines (Workbook (Instructor)) ______________________ 579422 (8636710)
Principles of Doubly-Fed Induction Generators (DFIG) (Workbook) ___________________________579435 (86376-00)
Principles of Doubly-Fed Induction Generators (DFIG) (Workbook (Instructor)) _________________ 579436 (8637610)
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
Courseware
Model
Qty Description
number
1 CD-ROM - PDF Manuals __________________________________________________________ 579738 (86367A0)
Optional Equipment
Model
Qty Description
number
1 Full-Size Blank EMS Module _____________________________________________________ 579757 (8160-00) 148
1 Half-Size Blank EMS Module ____________________________________________________ 579758 (8161-00) 149
1 Multimeters Module ___________________________________________________________ 586888 (8946A0) 150
Software
Model
Qty Description
number
1 Software Development Kit (SDK) _________________________________________________ 581441 (896870) 151
1 SCADA for LVDAC-EMS ________________________________________________________ 8094377 (8973-00) 152
1 Software Development Kit (SDK) _________________________________________________ 581459 (906990) 153
Workstation
Model
Qty Description
number
1 Mobile Workstation ____________________________________________________________ 579755 (811020) 154
1 Storage Shelves _________________________________________________________________ 579756 (815010)
1 Dust Cover for Workstations _______________________________________________________ 587004 (8991-00)
1 Dust Cover for EMS Storage Cabinet ________________________________________________ 587006 (8992-00)
1 Three-Phase Power Receptable - NEMA L22-20 ______________________________________ 768193 (24183-00)
1 Three-Phase Power Receptable - NEMA L21-20R _____________________________________ 768288 (24582-00)
1 Three-Phase Power Receptacle - 5-Pin Round ________________________________________ 775548 (35153-00)
147 The data acquisition already includes this function and many more, but the DC Circuits manual references using multimeters.
148 To mount your own devices.
149 To mount your own devices.
150 Can replace the Digital Multimeters.
151 Additional firmware for the Four-Quadrant Dynamometer/Power Supply.
152 Software allowing the monitoring of up to 5 Stations through OPC.
153 Additional firmware for the Data Acquisition.
154 Can replace the Tabletop Workstation included in the system.
Model
Qty Description
number
1 External Shelf for the Mobile Workstation _________________________________________ 581465 (36653-00) 155
1 Mounting Stand with Articulating Arm ___________________________________________ 8108710 (36653A0) 156
1 Mobile Base _________________________________________________________________ 587518 (88863-00) 157
System Specifications
Parameter Value
Sytem Requirements
Maximum Current 10 A
Typical Current 1.5 A per student group
3 phases (120/208 V – 60 Hz), star (wye) configuration including neutral and ground wires, protected by a 20 A
AC Power Network Installation
circuit breaker
AC Power Network Connector NEMA L21-20
A currently available personal computer with USB 2.0 ports, running under one of the following operating
Computer Requirements
systems: Windows® 7 or Windows® 8.
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 900 x 930 x 530 mm (35.4 x 36.6 x 20.9 in)
Net Weight TBE
EMS Modules
Full-Size Dimensions (H x W x D) 308 x 287 x 440 mm (12.1 x 11.3 x 17.3 in)
Half-Size Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
155 External Shelf for the Mobile Workstation, to put papers, laptop, keyboard, mouse, etc.
156 To mount your own monitor or touch screen
157 Mobile Base Plate
These courses introduce students to the fundamentals of SVCs, STATCOMs, and HVDC transmission systems.
Students learn that SVCs and STATCOMs, which are examples of flexible ac transmission systems (FACTS), can
be used in conjunction with HVDC transmission systems to greatly enhance the controllability and power
transfer capability of a power network and are thus essential tools to the implementation of a smart grid. These
courses also allow students to experiment with actual SVCs, STATCOMs, and HVDC transmission systems
implemented using power electronics modules.
The Power Transmission Smart Grid Technologies Training System is part of the Electric Power Technology
Training Systems, Series 8010. Each training system in Series 8010 is based on the Electric Power Technology
Training Program and provides a turn-key solution dealing with some aspects of the wide field of electrical
energy. The exhaustive courseware provided with each training system covers all the theory required to perform
the laboratory exercises, while review questions and unit tests allow students to test the knowledge they have
gained.
The Electric Power Technology Training Program is highly modular in both courseware and hardware. Because of
this, courses and equipment from the program are available as required, either individually or in the context of a
specific training system. The program covers several different subjects in the field of electrical energy, such as
rotating machines, electrical power transmission, power electronics, home energy production from renewable
resources (wind and sunlight), large-scale electricity production from hydropower and wind power, smart-grid
technologies (SVC, STATCOM, HVDC transmission, etc.), storage of electrical energy in batteries, and drive
systems for small electric vehicles and cars.
The above chart shows all courses in the Electric Power Technology Training Program. Blue boxes highlight courses included in the
training system covered in this datasheet, while dark grey boxes, if any, highlight courses that can be optionally added to this
training system.
Courseware
Each course in the training system includes a full-color student manual providing all the theoretical matter
required, guided lab-exercise procedures to be performed with the training equipment, and review questions
that test the knowledge gained by the student. Whenever possible, each course is built to bring the student to
actual applications as soon as possible. A full-color instructor guide providing all lab results and answers to
questions is also included with each course.
• The training system teaches the principles behind certain key technologies allowing the
implementation of a smart grid, within the context of power transmission. These technologies include
home energy production, SVCs, STATCOMs, and HVDC transmission systems.
• Realistic control functions implemented using the Data Acquisition and Control Interface via the LVDAC-
EMS software allow the implementation of complex devices such as an SVC and a STATCOM directly in
the laboratory.
• The course curriculum of the Electric Power Technology Training Program is highly flexible and allows a
multitude of different customized training solutions.
• The courseware includes student manuals and instructor guides with all the theory required to perform
the hands-on experiments.
• All workstations, modules, and components are sturdy and protected against electrical damage to
ensure a prolonged service life in a demanding environment such as a training laboratory.
• The modular design approach of the training equipment allows a large variety of courses to be
performed using a small number of modules, without unnecessary duplication of equipment.
• All electrical components can be interconnected without electric shock hazard since all live parts of the
connection leads are concealed and insulated.
• All electrical symbols representing the components used in a laboratory exercise are clearly silk-
screened on the front panel of the modules.
• The training system includes two highly versatile USB peripherals:
Four-Quadrant Dynamometer/Power Supply, Model 8960-2. This module is used as a solar panel
emulator with a large variety of configurable parameters.
Data Acquisition and Control Interface, Model 9063. This module gives access to a large variety of
computer-based measuring instruments and is used to control the various power electronics devices
necessary for home energy production, as well as SVC, STATCOM, and HVDC implantation. All
functions are implemented via the LVDAC-EMS software.
• The training system also includes four highly versatile power electronics modules controlled using the
Data Acquisition and Control Interface:
SVC Reactors/Thyristor Switched Capacitors, Model 8334. This module is used to implement the TCR
and TSCs for SVC operation.
Insulated DC-to-DC Converter, Model 8835. This module is used to implement a solar/wind power
inverter with HF transformer topology.
+ IGBT Chopper/Inverter, Model 8837-B. This module is used to implement the solar/wind power
inverter for home energy production and the three-phase PWM rectifier/inverter for STATCOM
operation.
Power Thyristors, Model 8841. This module is used to implement the TCR and TSCs for SVC operation
and the thyristor converters for HVDC operation.
• Software upgrades for LVDAC-EMS and firmware upgrades for the Four-Quadrant Dynamometer/Power
Supply and Data Acquisition and Control Interface are available for download free of charge on the
Festo Didactic website.
List of Equipment
Model
Qty Description
number
1 AC Transmission Line (Student Manual) ____________________________________________ 580204 (20521-00)
1 AC Transmission Line (Instructor Guide) ____________________________________________ 580205 (2052110)
1 Static Var Compensators (SVC) (Student Manual) ____________________________________ 579431 (86370-00)
1 Static Var Compensators (SVC) (Instructor Guide) ____________________________________ 579432 (8637010)
1 Static Synchronous Compensator (STATCOM) (Student Manual) ________________________ 579433 (86371-00)
1 Static Synchronous Compensator (STATCOM) (Instructor Guide) ________________________ 579434 (8637110)
1 High-Voltage DC Transmission Systems (Student Manual) _____________________________ 579460 (86380-00)
1 High-Voltage DC Transmission Systems (Instructor Guide) _____________________________ 579461 (8638010)
1 Tabletop Workstation ____________________________________________________________ 579484 (813420)
1 Resistive Load __________________________________________________________________ 763359 (8311-00)
2 Inductive Load __________________________________________________________________ 763362 (8321-00)
1 Three-Phase Filter _______________________________________________________________ 579529 (8326-00)
1 Line Inductors __________________________________________________________________ 763364 (8326A0)
2 Three-Phase Transmission Line ____________________________________________________ 579535 (8329-00)
3 Capacitive Load _________________________________________________________________ 763366 (8331-00)
1 SVC Reactors / Thyristor-Switched Capacitors ________________________________________ 763368 (8334-00)
2 Three-Phase Transformer Bank ____________________________________________________ 579559 (834840)
2 Three-Phase Regulating Autotransformer ____________________________________________ 763369 (8349-00)
1 Three-Phase Transformer _________________________________________________________ 763373 (8354-00)
1 Variable Three-Phase Power Supply ________________________________________________ 579603 (882120)
1 IGBT Chopper/Inverter ___________________________________________________________ 579623 (8837B0)
2 Power Thyristors ________________________________________________________________ 763376 (884120)
1 Connection Lead Set ______________________________________________________________ 579638 (8951L0)
1 Connection Lead Set _____________________________________________________________ 579639 (8951N0)
1 Four-Quadrant Dynamometer / Power Supply with Manual and Computer-Based Control _____ 579648 (8960C0)
1 Data Acquisition and Control Interface ______________________________________________ 579677 (9063-00)
1 Data Acquisition and Control Interface _______________________________________________ 579695 (9063J0)
List of Manuals
Manual
Description
number
Static Var Compensator (SVC) (Workbook) ______________________________________________579431 (86370-00)
Static Var Compensator (SVC) (Workbook (Instructor)) ____________________________________ 579432 (8637010)
Static Synchronous Compensator (STATCOM) (Workbook) _________________________________579433 (86371-00)
Static Synchronous Compensator (STATCOM) (Workbook (Instructor)) _______________________ 579434 (8637110)
HVDC Transmission Systems (Workbook) _______________________________________________579460 (86380-00)
HVDC Transmission Systems (Workbook (Instructor)) _____________________________________ 579461 (8638010)
AC Transmission Lines (Workbook) ____________________________________________________580204 (20521-00)
AC Transmission Lines (Workbook (Instructor)) __________________________________________ 580205 (2052110)
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
Optional Measurement
Model
Qty Description
number
1 Digital Multimeter _____________________________________________________________ 579782 (894620) 161
1 Acquisition functions __________________________________________________________ 581452 (906910) 162
Software
Model
Qty Description
number
1 Software Development Kit (SDK) _________________________________________________ 581441 (896870) 163
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 1 User Online, 1 year ____ 586971 (8972-00) 164
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 5 Users Online, 1 year ___ 586974 (8972A0) 165
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 10 Users Online, 1 year __ 586977 (8972B0) 166
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 15 Users Online, 1 year __ 586980 (8972C0) 167
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 20 Users Online, 1 year __ 586983 (8972D0) 168
Model
Qty Description
number
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 25 Users Online, 1 year __ 586986 (8972E0) 169
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 30 Users Online, 1 year __ 586989 (8972F0) 170
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 25 Users Online, 1 year __ 586992 (8972G0) 171
1 Electromechanical Systems Simulation Software (LVSIM®-EMS) - 40 Users Online, 1 year __ 586995 (8972H0) 172
1 SCADA for LVDAC-EMS ________________________________________________________ 8094377 (8973-00) 173
1 Acquisition functions __________________________________________________________ 581452 (906910) 174
1 Software Development Kit (SDK) _________________________________________________ 581459 (906990) 175
Workstation
Model
Qty Description
number
1 Mobile Workstation ____________________________________________________________ 579755 (811020) 176
1 Storage Shelves _________________________________________________________________ 579756 (815010)
1 Dust Cover for Workstations _______________________________________________________ 587004 (8991-00)
1 Dust Cover for EMS Storage Cabinet ________________________________________________ 587006 (8992-00)
1 Three-Phase Power Receptable - NEMA L22-20 ______________________________________ 768193 (24183-00)
1 Three-Phase Power Receptable - NEMA L21-20R _____________________________________ 768288 (24582-00)
1 Three-Phase Power Receptacle - 5-Pin Round ________________________________________ 775548 (35153-00)
1 External Shelf for the Mobile Workstation _________________________________________ 581465 (36653-00) 177
1 Mounting Stand with Articulating Arm ___________________________________________ 8108710 (36653A0) 178
1 Mobile Base _________________________________________________________________ 587518 (88863-00) 179
Optional Manual(s)
Model
Qty Description
number
1 Three-Phase Transformer Banks (Workbook) ______________________________________ 579448 (86379-00) 180
1 Three-Phase Transformer Banks (Workbook (Instructor)) ____________________________ 579451 (8637910) 181
System Specifications
Parameter Value
Sytem Requirements
Maximum Current 15 A
Typical Current 1.5 A per student group
169 Simulation software that covers transmission lines and more. Doesn't cover SCV and STATCOM.
170 Simulation software that covers transmission lines and more. Doesn't cover SCV and STATCOM.
171 Simulation software that covers transmission lines and more. Doesn't cover SCV and STATCOM.
172 Simulation software that covers transmission lines and more. Doesn't cover SCV and STATCOM.
173 Software allowing the monitoring of up to 5 Stations through OPC.
174 For the 2nd data acquisition unit.
175 Additional firmware for the Data Acquisition.
176 Can replace the Tabletop Workstation included in the system.
177 External Shelf for the Mobile Workstation, to put papers, laptop, keyboard, mouse, etc.
178 To mount your own monitor or touch screen.
179 Mobile Base Plate.
180 All the exercises in this manual can be performed with the current equipment list but this manual is not part of the system.
181 All the exercises in this manual can be performed with the current equipment list but this manual is not part of the system.
Parameter Value
3 phases (120/208 V – 60 Hz), star (wye) configuration including neutral and ground wires, protected by a 20 A
AC Power Network Installation
circuit breaker
AC Power Network Connector NEMA L21-20
A currently available personal computer with USB 2.0 ports, running under one of the following operating
Computer Requirements
systems: Windows® 7 or Windows® 8.
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 900 x 930 x 530 mm (35.4 x 36.6 x 20.9 in)
Net Weight TBE
EMS Modules
Full-Size Dimensions (H x W x D) 308 x 287 x 440 mm (12.1 x 11.3 x 17.3 in)
Half-Size Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
Courseware
Each course in the training system includes a full-color student manual providing all the theoretical matter
required, guided lab-exercise procedures to be performed with the training equipment, and review questions
that test the knowledge gained by the student. Whenever possible, each course is built to bring the student to
actual applications as soon as possible. A full-color instructor guide providing all lab results and answers to
questions is also included with each course.
• The course curriculum of the Electric Power Technology Training Program is highly flexible and allows a
multitude of different customized training solutions.
• Flexible learning system to which several other Smart Grid topics can be added such as Electric Power
Substations, Numerical Protective Relaying, Transmission Lines, SVC, STATCOM, HVDC, ...
• The courseware includes student manuals and instructor guides with all the theory required to perform
the hands-on experiments.
• All workstations, modules, and components are sturdy and protected against electrical damage to
ensure a prolonged service life in a demanding environment such as a training laboratory.
• The modular design approach of the training equipment allows a large variety of courses to be
performed using a small number of modules, without unnecessary duplication of equipment.
• All electrical components can be interconnected without electric shock hazard since all live parts of the
connection leads are concealed and insulated.
List of Equipment
Model
Qty Description
number
1 Circuit Breakers and Disconnecting Switches 1 _______________________________________ 588952 (3783-00)
1 Circuit Breakers and Disconnecting Switches 2 _______________________________________ 588953 (3783A0)
1 Fault Module ___________________________________________________________________ 588972 (3790A0)
1 Three-Module Workstation ________________________________________________________ 579483 (8131-00)
1 Tabletop Workstation ____________________________________________________________ 579484 (813420)
Model
Qty Description
number
1 Four-Pole Squirrel Cage Motor _____________________________________________________ 586267 (822120)
2 Resistive Load __________________________________________________________________ 763359 (8311-00)
1 Capacitive Load _________________________________________________________________ 763366 (8331-00)
2 Three-Phase Transformer Bank ____________________________________________________ 579559 (834840)
1 Three-Phase Power Supply ________________________________________________________ 579612 (8823-00)
1 DC Power Supply / Ethernet Switch _________________________________________________ 588954 (8824-00)
1 Timing Belt _____________________________________________________________________ 579637 (8942-00)
1 Connection Lead Set ____________________________________________________________ 8112387 (8951S0)
1 Four-Quadrant Dynamometer / Power Supply with Manual and Computer-Based Control _____ 579648 (8960C0)
1 Data Acquisition and Control Interface ______________________________________________ 579677 (9063-00)
1 Data Acquisition and Control Interface ______________________________________________ 579680 (9063B0)
2 Software Development Kit (SDK) ___________________________________________________ 581459 (906990)
1 AC 24 V Wall Mount Power Supply _________________________________________________ 579696 (3000420)
1 PLC Software (Step 7 Professional / WinCC) - 1 User ___________________________________ 587904 (5939-00)
List of Manuals
Manual
Description
number
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
Smart Grid (Workbook (Instructor)) ____________________________________________________________ 8107696
Smart Grid (Workbook) ______________________________________________________________________ 8107698
Courseware
Model
Qty Description
number
1 Electric Power Technology Training Systems (Manuals on CD-ROM) ______________________ 580543 (86350A0)
Optional Equipment
Model
Qty Description
number
1 Full-Size Blank EMS Module _____________________________________________________ 579757 (8160-00) 182
1 Half-Size Blank EMS Module ____________________________________________________ 579758 (8161-00) 183
1 Variable Three-Phase Power Supply ______________________________________________ 579603 (882120) 184
1 Multimeters Module ___________________________________________________________ 586888 (8946A0) 185
1 Personal Computer ______________________________________________________________ 579785 (8990-00)
1 All-in-One Touch Screen Computer (including Monitor Stand with Articulating Arm) _______ 8108708 (8990A0) 186
1 All-in-one computer _____________________________________________________________ 766480 (20628-00)
1 Touch-Screen Computer _________________________________________________________ 588298 (46299-00)
1 Touch-Screen Computer – Large ___________________________________________________ 589677 (46299A0)
Optional Measurement
Model
Qty Description
number
1 Digital Multimeter _____________________________________________________________ 579782 (894620) 187
Software
Model
Qty Description
number
1 Software Development Kit (SDK) _________________________________________________ 581441 (896870) 188
1 SCADA for LVDAC-EMS ________________________________________________________ 8094377 (8973-00) 189
Step 7 professional and WinCC Advanced, 6 users (perpetual) + 20 Students (1 year), Educational _____ 8164650
1
(8164650) 190
1 Step 7 professional and WinCC Advanced, 20 Students (1 year), Educational ___________ 8164652 (8164652) 191
Spare Part
Model
Qty Description
number
1 Connection Lead Set _____________________________________________________________ 581428 (8951-00)
Model
Qty Description
number
1 Fuse SB 5.0 A ________________________________________________________________ 780770 (71603-00) 192
Workstation
Model
Qty Description
number
1 Mobile Workstation ____________________________________________________________ 579755 (811020) 193
1 Storage Shelves _________________________________________________________________ 579756 (815010)
1 Dust Cover for Workstations _______________________________________________________ 587004 (8991-00)
1 Dust Cover for EMS Storage Cabinet ________________________________________________ 587006 (8992-00)
1 Three-Phase Power Receptable - NEMA L22-20 ______________________________________ 768193 (24183-00)
1 Three-Phase Power Receptable - NEMA L21-20R _____________________________________ 768288 (24582-00)
1 Three-Phase Power Receptacle - 5-Pin Round ________________________________________ 775548 (35153-00)
1 External Shelf for the Mobile Workstation _________________________________________ 581465 (36653-00) 194
1 Mounting Stand with Articulating Arm ___________________________________________ 8108710 (36653A0) 195
1 Mobile Base _________________________________________________________________ 587518 (88863-00) 196
System Specifications
Parameter Value
System Requirements
Maximum Current 15 A
Typical Current 1.5 A per student group
3 phases (120/208 V – 60 Hz), star (wye) configuration including neutral and ground wires, protected by a 20 A
AC Power Network Installation
circuit breaker
AC Power Network Connector NEMA L21-20
A currently available personal computer with USB 2.0 ports, running under one of the following operating
Computer Requirements
systems: Windows® 7, Windows® 8 or Windows® 10.
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 1275 x 930 x 530 mm (50.2 x 36.6 x 20.9 in)
Net Weight TBE
Courseware
Each course in the training system
includes a full-color student manual
providing all the theoretical matter
required, guided lab-exercise
procedures to be performed with the
training equipment, and review
questions that test the knowledge
gained by the student. Whenever
possible, each course is built to bring
the student to actual applications as
soon as possible. A full-color
instructor guide providing all lab
results and answers to questions is
also included with each course.
The above chart shows all courses in the Electric Power Technology Training
Program. Blue boxes highlight courses included in the training system covered
in this datasheet, while dark grey boxes, if any, highlight courses that can be
optionally added to this training system.
• Realistic control functions implemented using the Data Acquisition and Control Interface and Four-
Quadrant Dynamometer via the LVDAC-EMS software allow for a perfect emulation of hydropower plant
setup.
• The course curriculum of the Electric Power Technology Training Program is highly flexible and allows a
multitude of different customized training solutions.
• The courseware includes student manuals and instructor guides with all the theory required to perform
the hands-on experiments.
• All workstations, modules, and components are sturdy and protected against electrical damage to
ensure a prolonged service life in a demanding environment such as a training laboratory.
• The modular design approach of the training equipment allows a large variety of courses to be
performed using a small number of modules, without unnecessary duplication of equipment.
• All electrical components can be interconnected without electric shock hazard since all live parts of the
connection leads are concealed and insulated.
• All electrical symbols representing the components used in a laboratory exercise are clearly silk-
screened on the front panel of the modules.
• The training system includes two highly versatile USB peripherals:
Four-Quadrant Dynamometer/Power Supply, Model 8960-2. This module is used as a solar panel
emulator with a large variety of configurable parameters.
Data Acquisition and Control Interface, Model 9063. This module gives access to a large variety of
computer-based measuring instruments and is used to control the power thyristors bridge that
regulates the generator voltage with the AVR. All functions are implemented via the LVDAC-EMS
software.
• Software upgrades for LVDAC-EMS and firmware upgrades for the Four-Quadrant Dynamometer/Power
Supply and Data Acquisition and Control Interface are available for download free of charge on the
Festo Didactic website.
List of Equipment
Model
Qty Description
number
1 Hydropower Electricity Generation (Student Manual) _________________________________ 579742 (86369-00)
1 Hydropower Electricity Generation (Instructor Guide) _________________________________ 579743 (8636910)
1 Tabletop Workstation ____________________________________________________________ 579484 (813420)
1 Three-Phase Synchronous Motor/Generator _________________________________________ 579502 (824120)
1 Resistive Load __________________________________________________________________ 763359 (8311-00)
1 Inductive Load __________________________________________________________________ 763362 (8321-00)
1 Synchronizing Module / Three-Phase Contactor _______________________________________ 579576 (8621A0)
1 Three-Phase Power Supply ________________________________________________________ 579612 (8823-00)
1 Power Thyristors ________________________________________________________________ 763376 (884120)
1 Timing Belt _____________________________________________________________________ 579637 (8942-00)
1 Connection Lead Set ______________________________________________________________ 579638 (8951L0)
1 Connection Lead Set _____________________________________________________________ 579639 (8951N0)
1 Four-Quadrant Dynamometer / Power Supply with Manual and Computer-Based Control _____ 579648 (8960C0)
1 Turbine Emulator Function Set _____________________________________________________ 579783 (896830)
1 Data Acquisition and Control Interface ______________________________________________ 579680 (9063B0)
1 Synchronous Generator Control Function Set _________________________________________ 579788 (9069A0)
1 AC 24 V Wall Mount Power Supply _________________________________________________ 579696 (3000420)
List of Manuals
Manual
Description
number
Hydropower Electricity Generation (Workbook) __________________________________________579742 (86369-00)
Hydropower Electricity Generation (Workbook (Instructor)) ________________________________ 579743 (8636910)
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
Software
Model
Qty Description
number
1 Software Development Kit (SDK) _________________________________________________ 581441 (896870) 198
1 SCADA for LVDAC-EMS ________________________________________________________ 8094377 (8973-00) 199
1 Software Development Kit (SDK) _________________________________________________ 581459 (906990) 200
Workstation
Model
Qty Description
number
1 Three-Phase Power Receptable - NEMA L22-20 ______________________________________ 768193 (24183-00)
1 Three-Phase Power Receptable - NEMA L21-20R _____________________________________ 768288 (24582-00)
1 Three-Phase Power Receptacle - 5-Pin Round ________________________________________ 775548 (35153-00)
System Specifications
Parameter Value
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 890 x 935 x 465 mm (35.0 x 36.8 x 18.3 in)
Net Weight X kg (X lb)
resources (wind and sunlight), large-scale electricity production from hydropower and wind power, smart-grid
technologies (SVC, STATCOM, HVDC transmission, etc.), storage of electrical energy in batteries, and drive
systems for small electric vehicles and cars.
The above chart shows all courses in the Electric Power Technology Training Program. Blue boxes highlight courses included in the
training system covered in this datasheet, while dark grey boxes, if any, highlight courses that can be optionally added to this
training system.
Courseware
Each course in the training system includes a full-color student manual providing all the theoretical matter
required, guided lab-exercise procedures to be performed with the training equipment, and review questions
that test the knowledge gained by the student. Whenever possible, each course is built to bring the student to
actual applications as soon as possible. A full-color instructor guide providing all lab results and answers to
questions is also included with each course.
• Self-learning curriculum complete with the necessary theory and hands-on experiments
• All control of power electronics devices is computerized via LVDAC-EMS software, allowing for quick
setup and easy monitoring
• Totally safe and sturdy working environment with a complete and automatic grounding of all
components
• Top-of-the-line data acquisition measuring tools designed to enhance the learning approach and
reduce setup time
• Versatile power electronics modules (IGBT) easily reconfigurable in multiple different controllers
List of Equipment
Model
Qty Description
number
1 Tabletop Workstation ____________________________________________________________ 579484 (813420)
1 Permanent Magnet Synchronous Machine ___________________________________________ 586378 (8245-00)
1 Resistive Load __________________________________________________________________ 763359 (8311-00)
3 Lead-Acid Battery Pack ___________________________________________________________ 579591 (880210)
1 IGBT Chopper/Inverter ___________________________________________________________ 579623 (8837B0)
1 Timing Belt _____________________________________________________________________ 579637 (8942-00)
1 Connection Lead Set ______________________________________________________________ 579638 (8951L0)
1 Connection Lead Set _____________________________________________________________ 586897 (8951P0)
1 Four-Quadrant Dynamometer / Power Supply with Manual and Computer-Based Control _____ 579648 (8960C0)
1 Data Acquisition and Control Interface ______________________________________________ 579680 (9063B0)
1 BLDC Motor/PMSM Control Function Set ____________________________________________ 581457 (906960)
1 AC 24 V Wall Mount Power Supply _________________________________________________ 579696 (3000420)
List of Manuals
Manual
Description
number
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
Manual
Description
number
BLDC Motors and Vector Control PMSM Drives (Workbook) ________________________________585206 (86373-00)
BLDC Motors and Vector Control PMSM Drives (Workbook (Instructor)) ______________________ 585207 (8637310)
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
BLDC Motors and Vector Control PMSM Drives (Workbook) (585206 (86373-00))
• 1 PMSM Control Using a Three-Phase, Six-Step 120° Modulation Inverter
• 2 The BLDC Motor
• 3 The Vector Control PMSM Drive
Courseware
Model
Qty Description
number
1 Electric Power Technology Training Systems (Manuals on CD-ROM) ______________________ 580543 (86350A0)
Optional Equipment
Model
Qty Description
number
1 Full-Size Blank EMS Module _____________________________________________________ 579757 (8160-00) 201
1 Half-Size Blank EMS Module ____________________________________________________ 579758 (8161-00) 202
1 Variable Three-Phase Power Supply ______________________________________________ 579603 (882120) 203
1 Multimeters Module ___________________________________________________________ 586888 (8946A0) 204
1 Personal Computer ______________________________________________________________ 579785 (8990-00)
Model
Qty Description
number
1 All-in-One Touch Screen Computer (including Monitor Stand with Articulating Arm) _______ 8108708 (8990A0) 205
1 All-in-one computer _____________________________________________________________ 766480 (20628-00)
1 Touch-Screen Computer _________________________________________________________ 588298 (46299-00)
1 Touch-Screen Computer – Large ___________________________________________________ 589677 (46299A0)
Optional Measurement
Model
Qty Description
number
1 Digital Multimeter _____________________________________________________________ 579782 (894620) 206
Software
Model
Qty Description
number
1 Software Development Kit (SDK) _________________________________________________ 581441 (896870) 207
1 SCADA for LVDAC-EMS ________________________________________________________ 8094377 (8973-00) 208
1 Software Development Kit (SDK) _________________________________________________ 581459 (906990) 209
Spare Part
Model
Qty Description
number
1 Timing Belt _____________________________________________________________________ 579637 (8942-00)
1 Connection Lead Set _____________________________________________________________ 581428 (8951-00)
1 Fuse SB 5.0 A ________________________________________________________________ 780770 (71603-00) 210
Workstation
Model
Qty Description
number
1 Mobile Workstation ____________________________________________________________ 579755 (811020) 211
1 Storage Shelves _________________________________________________________________ 579756 (815010)
1 Dust Cover for Workstations _______________________________________________________ 587004 (8991-00)
1 Dust Cover for EMS Storage Cabinet ________________________________________________ 587006 (8992-00)
1 Three-Phase Power Receptable - NEMA L22-20 ______________________________________ 768193 (24183-00)
205 Mounts on the side of the workstation to save space. Could be replaced by another PC running Windows 10 and having one free USB 2.0 port.
206 The data acquisition already includes this function and many more, but the DC Circuits manual references using multimeters.
207 Additional firmware for the Four-Quadrant Dynamometer/Power Supply.
208 Software allowing the monitoring of up to 5 Stations through OPC.
209 Additional firmware for the Data Acquisition.
210 For the Data Acquisition (1 per current input).
211 Can replace the Tabletop Workstation included in the system.
Model
Qty Description
number
1 Three-Phase Power Receptable - NEMA L21-20R _____________________________________ 768288 (24582-00)
1 Three-Phase Power Receptacle - 5-Pin Round ________________________________________ 775548 (35153-00)
1 External Shelf for the Mobile Workstation _________________________________________ 581465 (36653-00) 212
1 Mounting Stand with Articulating Arm ___________________________________________ 8108710 (36653A0) 213
1 Mobile Base _________________________________________________________________ 587518 (88863-00) 214
System Specifications
Parameter Value
System Requirements
Maximum Current 15 A
Typical Current 1.5 A per student group
3 phases (120/208 V - 60 Hz), star (wye) configuration including neutral and ground protected by a 20 A circuit
AC Power Network Installation
breaker
AC Power Network Connector NEMA L21-20
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 890 x 935 x 465 mm (35.0 x 36.8 x 18.3 in)
Net Weight X kg (X lb)
212 External Shelf for the Mobile Workstation, to put papers, laptop, keyboard, mouse, etc.
213 To mount your own monitor or touch screen.
214 Mobile Base Plate.
technologies (SVC, STATCOM, HVDC transmission, etc.), storage of electrical energy in batteries, and drive
systems for small electric vehicles and cars.
The above chart shows all courses in the Electric Power Technology Training Program. Blue boxes highlight courses included in the
training system covered in this datasheet, while dark grey boxes, if any, highlight courses that can be optionally added to this
training system.
Courseware
Each course in the training system includes a full-color student manual providing all the theoretical matter
required, guided lab-exercise procedures to be performed with the training equipment, and review questions
that test the knowledge gained by the student. Whenever possible, each course is built to bring the student to
actual applications as soon as possible. A full-color instructor guide providing all lab results and answers to
questions is also included with each course.
• The course curriculum of the Electric Power Technology Training Program is highly flexible and allows a
multitude of different customized training solutions.
• The courseware includes student manuals and instructor guides with all the theory required to perform
the hands-on experiments.
• All workstations, modules, and components are sturdy and protected against electrical damage to
ensure a prolonged service life in a demanding environment such as a training laboratory.
• The modular design approach of the training equipment allows a large variety of courses to be
performed using a small number of modules, without unnecessary duplication of equipment.
• All electrical components can be interconnected without electric shock hazard since all live parts of the
connection leads are concealed and insulated.
• All electrical symbols representing the components used in a laboratory exercise are clearly silk-
screened on the front panel of the modules.
• Top of the line data acquisition and control interface designed for learning purposes.
List of Equipment
Model
Qty Description
number
1 Circuit Breakers and Disconnecting Switches 1 _______________________________________ 588952 (3783-00)
1 Circuit Breakers and Disconnecting Switches 2 _______________________________________ 588953 (3783A0)
1 Fault Module ___________________________________________________________________ 588972 (3790A0)
1 Tabletop Workstation ____________________________________________________________ 579484 (813420)
1 Resistive Load __________________________________________________________________ 763359 (8311-00)
1 Line Inductors __________________________________________________________________ 763364 (8326A0)
1 Three-Phase Power Supply ________________________________________________________ 579612 (8823-00)
1 DC Power Supply / Ethernet Switch _________________________________________________ 588954 (8824-00)
Model
Qty Description
number
1 Connection Lead Set _____________________________________________________________ 586891 (8951A0)
1 Data Acquisition and Control Interface ______________________________________________ 579680 (9063B0)
1 Software Development Kit (SDK) ___________________________________________________ 581459 (906990)
1 AC 24 V Wall Mount Power Supply _________________________________________________ 579696 (3000420)
1 PLC Software (Step 7 Professional / WinCC) - 1 User ___________________________________ 587904 (5939-00)
List of Manuals
Manual
Description
number
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
Introduction to Electric Power Substations (Workbook) ____________________________________589173 (20528-00)
Introduction to Electric Power Substations (Workbook (Instructor)) __________________________ 589174 (2052810)
Courseware
Model
Qty Description
number
1 Electric Power Technology Training Systems (Manuals on CD-ROM) ______________________ 580543 (86350A0)
Optional Equipment
Model
Qty Description
number
1 Full-Size Blank EMS Module _____________________________________________________ 579757 (8160-00) 215
Model
Qty Description
number
1 Half-Size Blank EMS Module ____________________________________________________ 579758 (8161-00) 216
1 Variable Three-Phase Power Supply ______________________________________________ 579603 (882120) 217
1 Multimeters Module ___________________________________________________________ 586888 (8946A0) 218
1 Personal Computer ______________________________________________________________ 579785 (8990-00)
1 All-in-One Touch Screen Computer (including Monitor Stand with Articulating Arm) _______ 8108708 (8990A0) 219
1 All-in-one computer _____________________________________________________________ 766480 (20628-00)
1 Touch-Screen Computer _________________________________________________________ 588298 (46299-00)
1 Touch-Screen Computer – Large ___________________________________________________ 589677 (46299A0)
Optional Measurement
Model
Qty Description
number
1 Digital Multimeter _____________________________________________________________ 579782 (894620) 220
Software
Model
Qty Description
number
1 Software Development Kit (SDK) _________________________________________________ 581441 (896870) 221
1 SCADA for LVDAC-EMS ________________________________________________________ 8094377 (8973-00) 222
Step 7 professional and WinCC Advanced, 6 users (perpetual) + 20 Students (1 year), Educational _____ 8164650
1
(8164650) 223
1 Step 7 professional and WinCC Advanced, 20 Students (1 year), Educational ___________ 8164652 (8164652) 224
Spare Part
Model
Qty Description
number
1 Connection Lead Set _____________________________________________________________ 581428 (8951-00)
1 Fuse SB 5.0 A ________________________________________________________________ 780770 (71603-00) 225
Workstation
Model
Qty Description
number
1 Mobile Workstation ____________________________________________________________ 579755 (811020) 226
1 Storage Shelves _________________________________________________________________ 579756 (815010)
1 Dust Cover for Workstations _______________________________________________________ 587004 (8991-00)
1 Dust Cover for EMS Storage Cabinet ________________________________________________ 587006 (8992-00)
1 Three-Phase Power Receptable - NEMA L22-20 ______________________________________ 768193 (24183-00)
Model
Qty Description
number
1 Three-Phase Power Receptable - NEMA L21-20R _____________________________________ 768288 (24582-00)
1 Three-Phase Power Receptacle - 5-Pin Round ________________________________________ 775548 (35153-00)
1 External Shelf for the Mobile Workstation _________________________________________ 581465 (36653-00) 227
1 Mounting Stand with Articulating Arm ___________________________________________ 8108710 (36653A0) 228
1 Mobile Base _________________________________________________________________ 587518 (88863-00) 229
System Specifications
Parameter Value
System Requirements
Maximum Current 15 A
Typical Current 1.5 A per student group
3 phases (120/208 V - 60 Hz), star (wye) configuration including neutral and ground protected by a 20 A circuit
AC Power Network Installation
breaker
AC Power Network Connector NEMA L21-20
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 890 x 935 x 465 mm (35.0 x 36.8 x 18.3 in)
Net Weight X kg (X lb)
• Overcurrent/Overload Protection
• Directional Protection
• Differential Protection
• Distance Protection
• Self-contained devices with internal testing capabilities not requiring external devices to create faults
• Power-utility grade equipment with Siemens' newest generation of the SIPROTEC 5 Series
227 External Shelf for the Mobile Workstation, to put papers, laptop, keyboard, mouse, etc.
228 To mount your own monitor or touch screen
229 Mobile Base Plate
List of Equipment
Model
Qty Description
number
1 Numerical Distance Relay _________________________________________________________ 589062 (3813-00)
1 Numerical Differential Protective Relay ______________________________________________ 589891 (3819-00)
List of Manuals
Manual
Description
number
Overcurrent and Overload Protection Using Protective Relays (Workbook) ____________________589887 (52173-00)
Overcurrent and Overload Protection Using Protective Relays (Workbook (Instructor)) __________ 589888 (5217310)
Directional Protection (Workbook) _____________________________________________________589889 (52174-00)
Directional Protection (Workbook (Instructor)) ___________________________________________ 589890 (5217410)
Differential Protection (Workbook) ____________________________________________________590085 (52175-00)
Differential Protection (Workbook (Instructor)) __________________________________________ 590086 (5217510)
Numerical Protective Relays (User Guide) _______________________________________________ 590108 (52766E0)
Distance Protection (Workbook) ______________________________________________________593880 (52176-00)
Distance Protection (Workbook (Instructor)) ____________________________________________ 593881 (5217610)
Numerische Schutzrelais (User Guide) _________________________________________________ 593908 (52766EG)
Relais de protection numériques (User Guide) ___________________________________________ 593909 (52766E1)
Relés numéricos de protección (User Guide) ____________________________________________ 593910 (52766E2)
Courseware
Model
Qty Description
number
1 Electric Power Technology Training Systems (Manuals on CD-ROM) ______________________ 580543 (86350A0)
Optional Equipment
Model
Qty Description
number
1 Personal Computer ______________________________________________________________ 579785 (8990-00)
1 All-in-one computer _____________________________________________________________ 766480 (20628-00)
1 Touch-Screen Computer _________________________________________________________ 588298 (46299-00)
1 Touch-Screen Computer – Large ___________________________________________________ 589677 (46299A0)
Workstation
Model
Qty Description
number
1 Mounting Frame (DIN A4) for EMS Workstations ___________________________________ 8138160 (8136PC) 231
System Specifications
Parameter Value
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 890 x 935 x 465 mm (35.0 x 36.8 x 18.3 in)
Net Weight X kg (X lb)
230 This license is intended only for the non-educational customers. For educational customer, the software is provided for free with a 10 users
Equipment Description
Circuit Breakers and Disconnecting Switches 1
588952 (3783-00)
The Circuit Breakers and Disconnecting Switches 1, Model
3783-0 can be operated independently using dedicated I/O
(open/close) switches or open/close control inputs on the front
panel. An Ethernet port on the module front panel allows all
circuit breakers and disconnecting switches to be controlled
independently using a SCADA system. Green (close) and red
(open) pilot lights on the front panel indicate the state of each
circuit breaker and disconnecting switch. Open/close auxiliary
contact sets are provided for each of the 3 circuit breakers.
Open/close auxiliary contact sets are provided for one of the
disconnecting switch. Module operation requires 120 V dc power
which is applied to the module via two safety banana jacks on
the front panel. Electric power substations with the following
switching schemes, i.e., the bus (busbar) arrangements, can be implemented using two Circuit Breakers and
Disconnecting Switches modules (Models 3783-0 and 3783-A):
• Single Bus
• Double Bus, Single Breaker
• Main Bus with Transfer Bus
• Ring Bus
• Breaker-and-a-Half
• Double Bus, Double Breaker
SCADA Application
Included with the module is the SCADA application that allows control and supervision of an electric power
substation implemented using modules Circuit Breakers and Disconnecting Switches 1 and 2, Models 3783-0
and 3783-A, respectively. This application must be installed on the host computer used to control the
substation.
The SCADA application displays the simplified diagram of the substation, integrating the main system controls
with the meters showing the values of the meaningful system parameters. This allows students to quickly
understand what is going on in the substation.
Specifications
Parameter Value
Contactor Ratings
Power Input 120 V dc – 100 mA
Control Inputs 120 V dc – 6 mA
Main Contacts 250 V ac – 6 A
Auxilliary Contacts 250 V ac – 2 A / 120 V dc – 0.3 A
Communication Port
Socket RJ45
Physical Characteristics
Dimensions (H x W x D) 308 x 287 x 490 mm (12.1 x 11.3 x 19.3 in)
Net Weight TBE
• Single Bus
SCADA Application
Included with the module is the SCADA application that allows control and supervision of an electric power
substation implemented using modules Circuit Breakers and Disconnecting Switches 1 and 2, Models 3783-0
and 3783-A, respectively. This application must be installed on the host computer used to control the
substation.
The SCADA application displays the simplified diagram of the substation, integrating the main system controls
with the meters showing the values of the meaningful system parameters. This allows students to quickly
understand what is going on in the substation.
Specifications
Parameter Value
Contactor Ratings
Power Input 120 V dc – 100 mA
Control Inputs 120 V dc – 6 mA
Main Contacts 250 V ac – 6 A
Auxilliary Contacts 250 V ac – 2 A / 120 V dc – 0.3 A
Communication Port
Socket RJ45
Physical Characteristics
Dimensions (H x W x D) 308 x 287 x 490 mm (12.1 x 11.3 x 19.3 in)
Net Weight TBE
Fault Module
588972 (3790A0)
The Fault Module consists of a three-phase normally open
contactor enclosed in a half-size EMS module. Each phase of the
contactor can be used to insert different types of faults in an
electric power circuit, such as ground faults and phase-to-phase
faults. Control of the contactor is achieved using either a toggle
switch or TTL control signals through a low-voltage control input.
Both the toggle switch and control inputs are located on the
module front panel. The Fault Module also includes a resistor
used to limit the intensity of the current flowing in any inserted
fault. Access to each phase of the contactor as well as to the resistor is achieved through safety banana jacks
on the module front panel.
Specifications
Parameter Value
Contactor Rating
Power Input 120 V – 40 mA – 60 Hz
Contacts 400 V – 3 A ac
Remote Control 0/3.5-5 V dc
Resistor Ratings
Resistor 60 Ω - 250 W
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight TBE
the front panel of the relay, allows users to select the information displayed. The front panel of the relay also
features a set of 16 LEDs that allows quick monitoring of the status of various relay functions.
Relay programming (e.g., protection function selection, function settings) is achieved via the Siemens DIGSI 5
software. This software is designed to be run from a personal computer with a Microsoft® Windows™ operating
system. Communication between the computer and the relay is through a USB port or an Ethernet port. Relay
function settings can also be performed using the keypad and display located on the front panel of the relay.
Once programmed, the Numerical Distance Relay can be tested using a built-in relay testing unit to ensure it is
programmed to operate as expected. This eliminates the need for users to purchase a costly external relay
tester to perform relay testing. The built-in relay testing unit is operated using the DIGSI 5 software.
Access to the voltage and current inputs of the Numerical Distance Relay is through a removable panel located
at the back of the relay enclosure. Access to the relay Ethernet port, binary inputs, and binary outputs (e.g., trip
contacts) is also through this removable panel. The Numerical Distance Relay is powered via an ac power inlet
mounted on the front of the relay enclosure. A variant of the Numerical Distance Relay with safety jacks and
connectors mounted on the front panel to provide access to all relay inputs, outputs, and ports is also available.
See the Numerical Distance Relay, Model 3813-A.
Courseware
Different courses are available to perform exercises using the Numerical Distance Relay. Each course consists of
a student manual providing comprehensive theory presentations, guided, easy-to-understand lab procedures,
and review questions. Each course also comprises an instructor guide that includes both the content of the
student manuals as well as the results and answers to questions.
The following table indicates which courses are available for each numerical protective relay.
List of Manuals
Manual
Description
number
Numerical Protective Relays (User Guide) _______________________________________________ 590108 (52766E0)
Numerische Schutzrelais (User Guide) _________________________________________________ 593908 (52766EG)
Relais de protection numériques (User Guide) ___________________________________________ 593909 (52766E1)
Relés numéricos de protección (User Guide) ____________________________________________ 593910 (52766E2)
Optional Manual(s)
Model
Qty Description
number
1 Overcurrent and Overload Protection Using Protective Relays (Workbook) ________________ 589887 (52173-00)
1 Overcurrent and Overload Protection Using Protective Relays (Workbook (Instructor)) ______ 589888 (5217310)
1 Directional Protection (Workbook) _________________________________________________ 589889 (52174-00)
1 Directional Protection (Workbook (Instructor)) _______________________________________ 589890 (5217410)
1 Distance Protection (Workbook) __________________________________________________ 593880 (52176-00)
1 Distance Protection (Workbook (Instructor)) ________________________________________ 593881 (5217610)
Specifications
Parameter Value
Relay Type Siemens 7SA82
Power Requirements
Voltage 100-240 V
Apparent Power 35 VA
Frequency 50/60 Hz
Input IEC C14 input on the front panel
Protection 6 A circuit breaker
Computer Interface
Connection RJ45 EtherNet port on the front panel
Software DIGSI 5 Software included, free license for educational institutions obtainable from Siemens via application
Physical Characteristics
On a work surface able to support the weight of the equipment, or on a Festo-approved A4 workstation or
Intended Location
equivalent
Dimensions (H x W x D) 295 x 260 x 240 mm (11.61 x 10.24 x 9.45 in)
Net Weight 7.08 kg (15.6 lb)
232 This license is intended only for the non-educational customers. For educational customer, the software is provided for free with a 10 users
Courseware
Different courses are available to perform exercises using the Numerical Differential Protective Relay. Each
course consists of a student manual providing comprehensive theory presentations, guided, easy-to-
understand lab procedures, and review questions. Each course also comprises an instructor guide that includes
both the content of the student manuals as well as the results and answers to questions.
The following table indicates which courses are available for each numerical protective relay.
List of Manuals
Manual
Description
number
Numerical Protective Relays (User Guide) _______________________________________________ 590108 (52766E0)
Numerische Schutzrelais (User Guide) _________________________________________________ 593908 (52766EG)
Relais de protection numériques (User Guide) ___________________________________________ 593909 (52766E1)
Relés numéricos de protección (User Guide) ____________________________________________ 593910 (52766E2)
Optional Manual(s)
Model
Qty Description
number
1 Overcurrent and Overload Protection Using Protective Relays (Workbook) ________________ 589887 (52173-00)
1 Overcurrent and Overload Protection Using Protective Relays (Workbook (Instructor)) ______ 589888 (5217310)
1 Differential Protection (Workbook) ________________________________________________ 590085 (52175-00)
1 Differential Protection (Workbook (Instructor)) ______________________________________ 590086 (5217510)
Specifications
Parameter Value
Relay Type Siemens 7UT82
Power Requirements
Voltage 100-240 V
Apparent Power 35 VA
Frequency 50/60 Hz
Input IEC C14 input on the front panel
Protection 6 A circuit breaker
233 This license is intended only for the non-educational customers. For educational customer, the software is provided for free with a 10 users
Parameter Value
Computer Interface
Connection RJ45 EtherNet port on the front panel
Software DIGSI 5 Software included, free license for educational institutions obtainable from Siemens via application
Physical Characteristics
On a work surface able to support the weight of the equipment, or on a Festo-approved A4 workstation or
Intended Location
equivalent
Dimensions (H x W x D) 295 x 260 x 240 mm (11.61 x 10.24 x 9.45 in)
Net Weight 7.08 kg (15.6 lb)
Specifications
Parameter Value
Software Step 7 Professional
Designed for SIMATIC® controllers, Step 7 allows programming in LAD, FBD, and STL languages. It also includes
Features
tools for graphic and high-level language programming.
A currently available personal computer Pentium type with RS-232 serial port, running under one of the
Computer Requirements
Microsoft® operating systems, Windows® 2000, Windows® XP, Windows® Vista or Windows® 7, is required.
Three-Module Workstation
579483 (8131-00)
The Three-Module Workstation is a fully assembled workstation
that serves the same purpose as the Mobile Workstation, Model
8110, but without any storage cabinet or pull-out work surface.
This workstation is intended for use on a bench (not supplied)
and is fitted with wooden feet to protect the bench top.
The Three-Module Workstation consists of a single row of three
full-height compartments that can accommodate up to three full-
size EMS modules or six half-size EMS modules.
Module Installation
The EMS modules are guided into position along stainless steel guide rails. Separators between each bay of the
workstation ensure perfect alignment of the EMS modules and allow their easy insertion in the workstation. A
holding mechanism ensures that each EMS module stays in place once it is installed in a compartment of the
workstation. A front-mounted push lever allows all EMS modules on the workstation to be released for easy
removal.
Additional Information
Three holes in the rear panel of the workstation allow connection to a power supply, as well as the connection of
2 kW machines to their interconnection modules. Assembly of the workstation before painting ensures that
each EMS module in the workstation is correctly grounded.
Manual
Manual
Description
number
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
Optional Equipment
Model
Qty Description
number
1 Industrial Controls Single-Rail Workstation _________________________________________ 581243 (3105A0) 234
1 Industrial Controls Double-Rail Workstation ________________________________________ 585964 (3105B0) 235
1 Mounting Frame (DIN A4) for EMS Workstations _____________________________________ 8138160 (8136PC)
1 Dust Cover for Workstation 8131 ___________________________________________________ 587005 (899110)
Specifications
Parameter Value
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 375 x 930 x 530 mm (14.8 x 36.6 x 20.9 in)
Net Weight TBE
Tabletop Workstation
579484 (813420)
The Workstation is a fully assembled workstation that serves the
same purpose as the Mobile Workstation but has no storage
cabinet or pull-out work surface. This workstation is intended for
use on a bench (not supplied) and is fitted with rubber feet to
protect the bench top. Alternatively, this workstation can be
mounted on either a Mobile Storage Cabinet, to make a Mobile
Workstation, or on a Mobile Base, to make a mobile workstation
without storage cabinet. In that case, it is possible to mount and
lock a second Workstation, on top of the first Workstation to
double the space available for EMS modules.
The Workstation consists of three rows of compartments
designed to house EMS modules. Two of these rows have full-
height compartments while the other row has half-height
compartments. Each row of full-height compartments can
accommodate up to three full-size EMS modules or six half-size EMS modules whereas the row of half-height
compartments can accommodate up to three half-size EMS modules.
234 This add-on workstation allows modules from the Industrial Controls Training Systems, Models 8036, to be installed in the EMS workstation.
Module Installation
The EMS modules are guided into position along stainless steel guide rails. Separators between each bay of the
workstation ensure perfect alignment of the EMS modules and allow their easy insertion in the workstation. A
holding mechanism ensures that each EMS module stays in place once it is installed in a compartment of the
workstation. Front-mounted push levers allow all EMS modules on a single row to be released for easy removal.
Additional Information
Six holes in the rear panel of the workstation allow connection to a power supply, as well as the connection of 2
kW machines to their interconnection modules. Assembly of the workstation before painting ensures that each
EMS module in the workstation is correctly grounded.
Manual
Manual
Description
number
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
Optional Equipment
Model
Qty Description
number
1 Industrial Controls Single-Rail Workstation _________________________________________ 581243 (3105A0) 236
1 Industrial Controls Double-Rail Workstation ________________________________________ 585964 (3105B0) 237
1 Mounting Frame (DIN A4) for EMS Workstations _____________________________________ 8138160 (8136PC)
1 All-in-One Touch Screen Computer (including Monitor Stand with Articulating Arm) _________ 8108708 (8990A0)
1 Dust Cover for Workstations _______________________________________________________ 587004 (8991-00)
1 Mounting Stand with Articulating Arm _____________________________________________ 8108710 (36653A0)
1 Mobile Base ___________________________________________________________________ 587518 (88863-00)
1 Mobile Storage Cabinet _________________________________________________________ 587519 (8911710)
Specifications
Parameter Value
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 890 x 935 x 465 mm (35.0 x 36.8 x 18.3 in)
Net Weight 31.8 kg (70 lb)
236 This add-on workstation allows modules from the Industrial Controls Training Systems, Models 8036, to be installed in the EMS workstation.
Specifications
Parameter Value
Rating
Power 220 W
Voltage 48 V
Current 5.0 A
Speed 3825 rpm
Maximum voltage 60 V
Maximum speed 4712 rpm
Pulley
Number of teeth 12
Physical Characteristics
Dimensions (H x W x D) 308 x 291 x 440 mm (2.1 x 11.5 x 17.3 in)
Net Weight 7.6 kg (16.8 lb)
Specifications
Parameter Value
Wind Turbine Type Direct-drive, fixed-pitch three blade rotor
Controller Output
Power 200 W at a wind speed of 12.5 m/s (28 mph)
Charge Voltage Setpoint Range 54.4-68.0 V
Recommended Battery Pack Voltage 48 V
Diode Rectifier 600 V – 6 A
Power Resistors
Ratings 15 Ω – 100 W (each resistor)
Quantity 3
Physical Characteristics
Dimensions (H x W x D) 308 x 291 x 440 mm (2.1 x 11.5 x 17.3 in)
Net Weight 12.0 kg (26.4 lb)
Specifications
Parameter Value
Motor
Stator Voltage 120/208 V, 3-phase
Mechanical Power 200 W
Nominal Speed 1685 r/min
Nominal Current 1.14 A
Power factor 0.73
Generator
Stator Voltage 120/208 V, 3-phase
Output Power 200 W
Nominal Speed 1900 r/min
Nominal Current 1.18 A
Power factor 0.47
Protection
Type 10 kΩ thermistor, type 2, in the stator windings
Physical Characteristics
Dimensions (H x W x D) 308 x 287 x 440 mm (12.1 x 11.3 x 17.3 in)
Net Weight TBE
Specifications
Parameter Value
Power Requirements 120/208 V
Motor
Stator Voltage 120/208 V, 3-phase
Rotor Voltage 360/624 V, 3-phase
Mechanical Power 200 W
Nominal Speed 1720 r/min
Nominal Current 1.15 A
Power Factor 0.64
Generator
Stator Voltage 120/208 V, 3-phase
Rotor Voltage 360/624 V, 3-phase
Power Input 480 VA
Power Output 200 W
Nominal Speed 1875 r/min
Nominal Current 1.33 A
Protections
Rotor overvoltage protection with push-button override
Thermal protection with thermistor outputs, 10 kΩ, LV type 2
Physical Characteristics
Dimensions (H x W x D) 308 x 291 x 440 mm (12.1 x 11.5 x 17.3 in)
Net Weight TBE
Specifications
Parameter Value
Power Requirement 120/208 V
Motor
Stator Voltage 120/208 V, three-phase
Rotor Voltage 0-150 V dc
Output Power 200 W
Synchronous Speed 1800 r/min
Full-Load Current 0.55 A
Power Factor 1
Generator
Stator Voltage 120/208 V, three-phase
Rotor Voltage 0-150 V dc
Output Power 200 VA
Synchronous Speed 1800 r/min
Power Factor 0.8
Protection
Type 10 kΩ thermistor, type 2, in the stator winding, and rotor field bimetal thermal protection
Physical Characteristics
Dimensions (H x W x D) 308 x 291 x 440 mm (12.1 x 11.5 x 17.3 in)
Net Weight TBE
Specifications
Parameter Value
Motor
Nominal Power 260 W (0.35 hp)
Nominal Speed 6000 rpm
Nominal Torque 0.41 N·m (3.6 lb·in)
Nominal Current 3A
Back EMF 10.4 V / krpm
Maximum Rated DC Bus Voltage 160 Vdc
Continous Torque (Stall) 0.47 N·m (4.2 lb·in)
Peak Torque 1.65 N·m (14.6 lb·in)
Rotor Type SPM (Surface Permanent Magnet)
Feedbacks
Digital Encoder 2048 Pulses per revolution – 0/5 Vdc differential
Hall Effect Sensor 0/5 Vdc
Thermistor Temperature protection to connect to Lab-Volt controller – Model 9063
Physical Characteristics
Dimensions (H x W x D) 308 x 291 x 440 mm (12.1 x 11.5 x 17.3 in)
Net Weight TBE
Resistive Load
763359 (8311-00)
The Resistive Load consists of a module housing nine wire-
wound power resistors arranged in three identical banks. Each
bank consists of three resistors connected in parallel that can be
switched on or off with toggle switches to obtain various
resistance values. This allows the total (equivalent) resistance of
each bank to be increased or decreased by steps. Six safety
banana jacks on the module front panel provide access to each
resistor bank. The three resistor banks can be connected
separately for operation in three-phase circuits. Also, the three
resistor banks can be connected together for operation in single-
phase circuits.
The Resistive Load is commonly used in conjunction with other basic load modules, like the Inductive Load and
the Capacitive Load to experiment with the effects of different types of loads on a circuit.
Specifications
Parameter Value
Resistors
Quantity Three identical banks of three resistors
Resistance Values (Each Group) 300/600/1200 Ω
Nominal Voltage 120 V ac/dc
Resistance Value Accuracy ± 5%
Load at Nominal Voltage (Each Bank)
Power 12-84 W
Current 0.1-0.7 A
Steps Seven, of equal increment
Current Increment 0.1 A
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 4.5 kg (9.9 lb)
Color
Front panel color Black
Inductive Load
763362 (8321-00)
The Inductive Load consists of a module housing nine iron-core
power inductors arranged in three identical banks. Each bank
consists of three inductors connected in parallel that can be
switched on or off with toggle switches to obtain various
inductance values. This allows the equivalent inductance of each
bank to be increased or decreased by steps. Six safety banana
jacks on the module front panel provide access to each inductor
bank. The three inductor banks can be connected separately for
operation in three-phase circuits. Also, the three inductor banks
can be connected together for operation in single-phase circuits.
The Inductive Load is commonly used in conjunction with other basic load modules, like the Resistive Load and
the Capacitive Load to experiment with the effects of different types of loads on a circuit.
Specifications
Parameter Value
Inductors
Quantity Three identical banks of three inductors
Inductance Values (Each Bank) 0.8/1.6/3.2 H
Reactance Values (Each Bank) 300/600/1200 Ω
Nominal Voltage 120 V – 60 Hz
Inductance Value Accuracy ± 5%
Load at Nominal Voltage (Each Bank)
Reactive Power 12-84 var
Current 0.1-0.7 A
Steps Seven, of equal increment
Current Increment 0.1 A
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 10.1 kg (22.3 lb)
Filtering Inductors/Capacitors
579523 (8325A0)
This Filtering Inductors/Capacitors module consists of two separate
filters enclosed in a half-size EMS module: a low-frequency filter and
a high-frequency filter. The low-frequency filter consists of an
inductor and a polarized capacitor, while the high-frequency filter
consists of two inductors and a non-polarized capacitor. Internal
electrical components are identified on the module front panel. 4
mm banana jacks provide access to the different components in the
module.
Specifications
Parameter Value
Low Frequency Filter
Inductance 50 mH - 5 A - 0-2 kHz
Capacitor (Aluminium Electrolytic) 210 µF - 450 V
High Frequency Filter
Inductance (2) 2 mH - 5 A - 0-20 kHz
Capacitor (Metallized Polypropylene) 5 µF - 400 V
Supplementary Capacitor (Met. Prop.) N/A
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
Net Weight 12.3 kg (27.12 lb)
Three-Phase Filter
579529 (8326-00)
The Three-Phase Filters consists of three inductors and four
capacitors enclosed in a half-size EMS module. Eight safety
banana jacks on the module front panel provide access to the
three-phase filter. The module is used to filter three-phase
signals in power electronics applications.
Specifications
Parameter Value
Inductors
Number 3
Ratings 2 mH – 5 A – 0-20 kHz
Capacitors
Number 4
Type Metallized polypropylene
Ratings 5 µF – 400 V
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
Net Weight TBE
Line Inductors
763364 (8326A0)
The Line Inductors module consists of three separate inductors
enclosed in a half-size EMS module to be connected in series in a
three-phase circuit. Six safety banana jacks provide individual
access to each inductor. The Line Inductors are used to limit the
rate of change of line currents in three-phase ac power systems.
Specifications
Parameter Value
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
Net Weight TBE
Inductors
Number 3
Ratings 25 mH – 1.5 A – 50/60 Hz
Specifications
Parameter Value
Ratings
Line Reactance Settings 0, 60, 120, and 180 Ω
Nominal Line Current 1A
Line Simulated Lengths 175, 350 and 525 km (109, 217 and 326 miles)
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
Net Weight 8.2 kg (18 lb)
Shipping Weight 9.8 kg (21.6 lb)
Capacitive Load
763366 (8331-00)
The Capacitive Load consists of a module housing nine
capacitors arranged in three identical banks. Each bank consists
of three capacitors connected in parallel that can be switched on
or off with toggle switches to obtain various capacitance values.
This allows the equivalent capacitance of each bank to be
increased or decreased by steps. Six safety banana jacks on the
module front panel provide access to each capacitor bank. The
three capacitor banks can be connected separately for operation
in three-phase circuits. Also, the three capacitor banks can be
connected together for operation in single-phase circuits.
A permanently connected discharge resistor reduces the voltage across the terminals of each bank of capacitors
to 5% of the applied voltage within 25 seconds after the load is disconnected from the supply. The Capacitive
Load may be used with both dc and ac power.
The Capacitive Load is commonly used in conjunction with the other basic load modules, the Resistive Load and
the Inductive Load to experiment with the effects of different types of loads on a circuit.
Specifications
Parameter Value
Capacitors
Quantity Three identical banks of three capacitors
Capacitance Values (Each Bank) 2.2/4.4/8.8 µF
Reactance Values (Each Bank) 300/600/1200 Ω
Nominal Voltage 120 V – 60 Hz
Maximum Voltage 230 V
Capacitance Value Accuracy ± 5%
Load at Nominal Voltage (Each Bank)
Reactive Power 12-84 var
Current 0.1-0.7 A
Steps Seven, of equal increment
Current Increment 0.1 A
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 5.7 kg (12.6 lb)
Specifications
Parameter Value
SVC Reactors
Quantity 3
Impedance 465 Ω
Ratings 120 V - 60 Hz
Reactive Power 31 var
SVC Thyristor-Switched Capacitors
Quantity 6
Impedance 600 Ω
Ratings 120 V - 60 Hz
Reactive Power 24 var
Switching Control Inputs 0/3.5 V (9 mA) and 0/5 V (15 mA)
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
Net Weight TBE
Specifications
Parameter Value
Rating (Each Transformer)
Primary Voltage 208 V
Secondary Voltage 208/120 V
Power 250 VA
Full-Load Current 1.2 A
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 13.9 kg (30.6 lb)
indicator on the module front panel indicates the phase sequence of the voltages across the autotransformer.
Specifications
Parameter Value
Rating
Line Voltage 120/208 V
Power 360 VA
Line Current 1A
Buck-Boost Voltage -15, 0, -15%
Phase Shift -15, 0, -15°
Phase Sequence 1-2-3
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm; (6.1 x 11.3 x 17.3 in)
Net Weight 7.6 kg (16.7 lb)
Shipping Weight 9.2 kg (20.2 lb)
Transformer
763371 (8353-00)
The Transformer consists of a power transformer enclosed in a
module. Both the primary and secondary sides of the
Transformer are made of two identical separate windings.
Banana jacks on the module front panel provide access to each
winding, allowing connection in a variety of configurations. The
Transformer has a turns ratio of 1:5, when considering the
totality of its primary and secondary windings. The Transformer
windings are polarized and the polarity of each winding is
indicated by a small dot on the module front panel. A thermistor
output allows monitoring of transformer temperature to prevent
overheating. A typical application of the Transformer is to convert the energy stored in batteries to a suitable
voltage level (for example, to the level of the ac power network voltage).
Specifications
Parameter Value
Nominal Power 240 VA
Primary Rating (2 windings) 24 V AC – 5 A for each winding
Secondary Rating (2 windings) 120 V ac – 1 A for each winding
Protection 10 kΩ thermistor, type 2
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 16.1 in)
Net Weight TBE
Three-Phase Transformer
763373 (8354-00)
The Three-Phase Transformer is a three-phase power tranformer,
made up of a single magnetic core with three branches, enclosed
in a half-size EMS module. It is used to adjust the ac power
network voltage to a value more suitable for certain power
electronics applications. For example, the Three-Phase
Transformer is used to adapt the value of the three-phase ac
power network voltage to the value of the dc bus voltage in
three-phase PWM rectifiers/inverters. Twelve banana jacks on
the module front panel provide individual access to each phase
of the power transformer, allowing connection in wye or delta
configuration.
Specifications
Parameter Value
Rating (Each Phase Winding)
Primary Voltage 120 V
Secondary Voltage 83 V
Power 200 VA
Primary Current 1.7 A
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
Net Weight TBE
Traffic Lights
579574 (8380-00)
The Traffic Lights module simulates a real-world traffic light
application that can be used as a load for a fuel cell system.
Specifications
Parameter Value
Input Voltage 12 V dc
Power Consumption Max. 10 W
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
Net Weight TBE
Electronic Load
579575 (8381-00)
The Electronic Load provides manual or computer-assisted
adjustment of constant rated currents that can be used to record
the characteristic curves of a fuel cell system, allowing users to
monitor the effects of different parameters.
Specifications
Parameter Value
Maximum continuous power output 200 W
Load voltage 1.2 – 20 V dc
Load current 0 – 10 A
Mains connection 120 – 240 V (50 – 60 Hz)
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
Net Weight TBE
Specifications
Parameter Value
Contactor
Power Input 120 V – 100 mA – 60 Hz
Contacts 400 V – 3 A ac
Light Bulbs (3)
Rating 28 V – 2.3 W – T 3 1/4
Remote Control Input
Voltage 0/3.5-5 V dc
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
Net Weight 3.6 kg (7.9 lb)
Shipping Weight 5.2 kg (11.4 lb)
Specifications
Parameter Value
AC Power Inlet
Rating 120 V - 2 A - 60 Hz
Type C14 connector
Circuit Breaker 2A
AC Power Outlet
Rating 120 V - 8 A - 60 Hz
Type NEMA 5-15 (type B)
Solid-State Relay
Coil Rating 3 to 32 V dc - 15 mA
Contact Rating 24 to 240 V - 8 A - 60 Hz
Filtering Inductor 2 mH - 5 A - 0 to 20 kHz
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
Net Weight TBE
Lead-Acid Batteries
763374 (8801-00)
The Lead-Acid Batteries module consists of two 12 V valve-
regulated, lead-acid (VRLA) batteries enclosed in a half-size EMS
module. These batteries are part of the Electric Power
Technology Training Program and are used to study lead-acid
battery characteristics as well as the storage of electrical energy
in various applications, such as solar power and wind power
electricity generation. They can easily be charged using the Four-
Quadrant Dynamometer/Power Supply, Model 8960-2.
The batteries can be connected in series or parallel. Connection
to the batteries is through 4 mm safety banana jacks mounted
on the front panel of the module. These jacks are used when large amounts of power are supplied to the
batteries or drawn from the batteries. A pair of miniature (2 mm) banana jacks mounted on the front panel of
the module provides access to one of the two batteries via a low-capacity auto-reset fuse. These miniature jacks
are used to connect the battery to either the Solar Panel Test Bench, Model 8805, or the Solar Panel, Model
8806, when performing lab exercises dealing with the storage of electrical energy produced from solar power.
Specifications
Parameter Value
Batteries
Quantity 2
Type Valve-regulated lead-acid
Voltage 12 V
Capacity 2.3 Ah
Maximum Charge Current 0.69 A
Maximum Discharge Current 5A
Auto-Reset Protective Fuse
Battery 5 A (hold current), 10 A (trip current)
Test Point 0.1 A (hold current), 0.2 A (trip current)
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
Net Weight 4.6 kg (10.2 lb)
Specifications
Parameter Value
Battery Pack
Type 4 valve-regulated lead-acid batteries
Voltage 48 V (12 V for each battery)
Capacity 9 Ah
Maximum Charge Current 2.7 A
Maximum Discharge Current 7A
Parallel Charging Input 58 V maximum
Overcurrent Protection
Battery Pack Fuse 10 A
Test Point Limiting Resistors (3) 1 kΩ
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
Net Weight TBE
Specifications
Parameter Value
Rated Output 40 W
Maximum Output 50 W
No-Load Voltage 9V
Current at Rated Output 8A
Hydrogen Consumption at Rated Output 580 sml/min
Hydrogen Purity for Operation A minimum of 4.0 (99.99%)
Permissible Hydrogen Pressure 0.4 – 0.8 bar
Permissible Ambient Temperature during Operation 5–35°C (41-95°F)
Communication Port USB
Pressure Regulator
Description Two-stage, hydrogen
Inlet Pressure Max. 19 bar
Outlet Pressure 0.6 ± 0.1 bar
Accessories
Leak detection kit
Safety connection leads
Software
Physical Characteristics
Dimensions (H x W x D) 307 x 579 x 533 mm (12.1 x 22.8 x 21 in)
Net Weight TBE
A potentiometer and a set of diodes are included in the Solar Panel Test Bench. The potentiometer is used to
apply a variable electrical load to the output of the solar panel under test. The diodes can be connected to the
solar panel to serve as either bypass diodes or blocking diodes. Access to the potentiometer and diodes is
through miniature (2 mm) banana jacks mounted on the front panel of the test bench. Four other miniature
banana jacks on the front panel of the test bench provide direct access to the output terminals of the solar
panel to make connections easy. A set of connection leads terminated with miniature banana plugs is provided
with the Solar Panel Test Bench.
Specifications
Parameter Value
Power Requirements
Current 3A
Service Installation Standard single-phase outlet
Halogen Lamp
Power 300 W
Ventilation System
Flow Rate 115 CFM
Potentiometer Single Turn – 500 Ω – 2 W
Diodes
Quantity 3
Peak Inverse Voltage 1000 V
Maximum Current 1A
Physical Characteristics
Dimensions (H x W x D) 308 x 291 x 440 mm (2.1 x 11.5 x 17.3 in)
Net Weight 6.9 kg (15.2 lb)
Monocrystalline Silicon Solar Panel installed in the Solar Panel Test Bench
(setup for indoor exercises).
Specifications
Parameter Value
PV Module
Quantity 2
Type Monocrystalline Silicon
Number of Cells 18
Open-Circuit Voltage (VOC) 9 V @ STC
Short-Circuit Current (ISC) 100 mA @ STC
Parameter Value
Potentiometer Single Turn - 500 Ω - 2 W
Diodes
Quantity 3
Peak Inverse Voltage 1000 V
Maximum Current 1A
Thermometer
Range -50°C to +70°C (-58°F to +158°F)
Resolution ±0.1° from -19.9° to +199.9°, otherwise 1°
Accuracy ±1°C from -30°C to +70°C (±1.8°F from -22°F to +158°F)
Battery Voltage 1.5 V
Battery Type A76 (LR44, G13) size or equivalent, 1 required
Angular Markers
Range 65°
Interval 5°
Physical Characteristics
Dimensions (H x W x D) 240 x 237 x 58 mm (9.4 x 9.3 x 2.3 in)
Net Weight 2.0 kg (4.4 lb)
Optional Equipment
Model
Qty Description
number
1 Three-Phase Power Receptable - NEMA L21-20R _____________________________________ 768288 (24582-00)
Specifications
Parameter Value
Module Requirements
3 phases (120/208 V – 60 Hz), star (wye) configuration including neutral and ground wires, protected by a 20 A
AC Power Network Installation
circuit breaker
AC Power Network Connector NEMA L21-20
Maximum Current 15 A
Outputs (*see note)
Three-Phase Fixed AC 120/208 V – 15 A - 60 Hz
Three-Phase Variable AC 0-120/208 V – 5 A - 60 Hz
Variable DC 0-120 V – 8 A
Fixed DC 120 V – 2 A
Low Power AC 24 V – 3 A - 60 Hz
Included Accessories
3 m (10 ft) AC power cord (1)
Parameter Value
Padlock (1)
Physical Characteristics
Dimensions (H x W x D) 308 x 287 x 495 mm (12.1 x 11.3 x 19.5 in)
Net Weight 18.4 kg (40.5 lb)
The Power Supply cannot supply all the amounts of current indicated by the current ratings on its front panel at
the same time. The current indicated for the fixed ac three-phase output section can only be obtained if no
current is drawn from any other section, because this section is protected by the main circuit breaker common to
every section. If currents flow in other sections, the available current for the fixed ac three-phase output section
*Note decreases. The variable ac output section and the variable dc output section are protected by a common set of
circuit breakers placed after the fixed ac three-phase output section, which means that the current capacity has
to be shared between the two sections. For instance, if current of the variable dc output section is at 70% of its
nominal value, current drawn from the variable ac output section should not exceed 30% of its nominal value. The
fixed dc output section is also protected by circuit breakers placed after the fixed ac three-phase output section.
Optional Equipment
Model
Qty Description
number
1 Three-Phase Power Receptable - NEMA L21-20R _____________________________________ 768288 (24582-00)
Specifications
Parameter Value
Power Requirements
Maximum Current 10 A
3 phases (120/208 V – 60 Hz), star (wye) configuration including neutral and ground wires, protected by a 20 A
AC Power Network Installation
circuit breaker
AC Power Network Connector NEMA L21-20
Outputs
Fixed AC 3-Phase 120/208 V – 5 A
Fixed DC 120 V – 4 A
Included Power Cord 3 m (10 ft)
Physical Characteristics
Dimensions (H x W x D) 212 x 287 x 496 mm (8.3 x 11.3 x 19.5 in)
Net Weight 5.7 kg (12.5 lb)
Specifications
Parameter Value
Power Requirements
Voltage 100-240 V
Apparent Power 550 VA
Outputs
Voltage 120 V dc
Current 4A
Ethernet Switch
Transmission rate 10-100 Mbit/s
Number Of Port 5
Sockets RJ45
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight TBE
Specifications
Parameter Value
Input
Rating 285 W - 40-55 V dc
Circuit Breaker 7A
Output Rating 250 W - 150-220 V dc
Switching Control Inputs
Quantity 2
Parameter Value
Signal Level 0-5 V (TTL compatible)
Nominal Frequency 36 kHz
Maximum Duty Cycle per signal 45 %
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
Net Weight TBE
IGBT Chopper/Inverter
579623 (8837B0)
The IGBT Chopper/Inverter module consists of seven insulated-
gate bipolar transistors (IGBT) mounted in a half-size EMS
module. Six IGBTs are used to implement choppers and
inverters. These IGBTs are protected against a variety of
abnormal operating conditions, such as short-circuits,
overvoltage, overcurrent, and overheat. The seventh IGBT and a
dumping resistor allow smooth dissipation of excess energy at
the dc bus. The dumping circuit can be activated through the use
of a toggle switch on the front panel.
The module switching control section allows 0/5 V pulse signals from either the Data Acquisition and Control
Interface, Model 9063, the Chopper/Inverter Control Unit, Model 9029, or any compatible 0/5 V control unit, to
be applied to the gating circuits of the IGBTs. The signals are input in the IGBT Chopper/Inverter module
through a nine-pin connector.
Six miniature banana jacks can be used as test points to monitor the pulse signals using an oscilloscope. These
jacks can also be used to inject 0/5 V pulse signals from an alternate control unit, as well as to inhibit each
gating circuit. The IGBT Chopper/Inverter module also includes a synchronization output to trigger an
oscilloscope when observing the switching control signals, as well as a switching control disable input that
allows all six IGBTs in the chopper/inverter section to be switched off.
Specifications
Parameter Value
DC Bus
Maximum Voltage 420 V
Maximum Current 6A
Filtering Capacitor 1360 µF
Protections
DC Bus Overvoltage 440 V
DC Bus Circuit Breaker 6A
IGBT Electronic Overcurrent 12 A
IGBT Overheat About 70°C
Dumping Circuit
Voltage Threshold 330 V
Resistor 100 Ω, 100 W
Switching Control Signals
Level 0/5 V
High Level Current 10 mA
Frequency Range 0-20 kHz
Minimum Dead Time 700 ns
Power Requirements 24 V, 0.16 A, 50/60 Hz
Accessories
Accessories 24 V power cable (1)
2 mm banana plug test leads (2)
Physical Characteristics
Parameter Value
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 5.67 kg (12.5 lb)
Power Thyristors
763376 (884120)
The Power Thyristors module consists of six power thyristors
(SCRs) mounted in a half-size EMS enclosure. Each individual
thyristor is protected against overcurrents and short-circuits. All
the anodes and cathodes of the thyristors are terminated on the
front panel by color-coded, 4 mm safety banana jacks. To reduce
the number of external connections, the most typical thyristor
configurations can be achieved through the use of two toggle
switches on the front panel.
A firing control section allows six 0-5 V pulse signals from either
the Data Acquisition and Control Interface, Model 9063, the Thyristor Firing Unit, Model 9030, or any compatible
0-5 V control unit, to be applied to the gating circuits of the thyristors. The signals are input in the Power
Thyristors module through a nine-pin connector.
Six miniature banana jacks in this section are used as test points to monitor the firing control signals using an
oscilloscope. They can also be used to inject 0-5 V pulse signals from an alternate firing unit, as well as to
inhibit each gating circuit. The Power Thyristors module also includes a synchronization output to trigger an
oscilloscope when observing the firing control signals as well as a firing control disable input that prevents all
six power thyristors from being fired.
Specifications
Parameter Value
Rating
Peak Inverse Voltage 600 V
Maximum Current 2A
Gate Control Signals 0-5 V Pulses (TTL compatible)
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
Net Weight 5.6 kg (12.35 lb)
Specifications
Parameter Value
Electrical Characteristics
Maximum Network Voltage 230 V - 3~ - 50/60 Hz
Maximum Diode Current 8A
Each Capacitor 210 µF - 450 V dc
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
Net Weight 2.9 kg (6.4 lb)
Timing Belt
579637 (8942-00)
The Timing Belt is a high-quality industrial synchro-cog timing
belt made of rubber whose teeth exactly mesh with the geared
pulley fitted on the shaft of all 0.2 kW EMS machines. The Timing
Belt is supplied in a fixed length appropriate for coupling two
adjacent EMS machines together without slippage between
them.
Specifications
Parameter Value
Physical Characteristics
Pitch 9.5 mm (0.375 in)
Pitch Length 819 mm (32.25 in)
Number of Teeth 86
Dimensions (Width) 12.7 mm (0.5 in)
Net Weight 0.1 kg (0.2 lb)
Specifications
Parameter Value
4 mm Safety Banana Plug Leads Characteristics
Cross Section 1 mm² (1974 cmil)
Rated Current 19 A
Rated Voltage 600 V, CAT II
4 mm Safety Banana Plug Leads Quantities
Yellow, 30 cm (12 in) 16
Red, 60 cm (24 in) 16
Blue, 90 cm (36 in) 8
Specifications
Parameter Value
4 mm Safety Banana Plug Leads Characteristics
Cross Section 1 mm² (1974 cmil)
Rated Current 19 A
Rated Voltage 600 V, CAT II
4 mm Safety Banana Plug Leads Quantities
Yellow, 30 cm (12 in) 20
Red, 60 cm (24 in) 10
Blue, 90 cm (36 in) 4
2 mm Safety Banana Plug Leads Characteristics
Cross Section 0.5 mm² (987 cmils)
Rated Current 10 A
Rated Voltage 30 V ac / 60 V dc
2 mm Safety Banana Plug Leads Quantities
Red, 60 cm (24 in) 4
Specifications
Parameter Value
4 mm Safety Banana Plug Leads Characteristics
Cross Section 1 mm² (1974 cmil)
Rated Current 19 A
Rated Voltage 600 V, CAT II
4 mm Safety Banana Plug Leads Quantities
Yellow, 30 cm (12 in) 14
Red, 60 cm (24 in) 8
Blue, 90 cm (36 in) 4
Three-Phase 4 mm Safety Banana Plug Leads
Characteristics
Cross Section 1 mm² (1974 cmil)
Rated Current 19 A
Rated Voltage 600 V, CAT II
Three-Phase 4 mm Safety Banana Plug Leads
Quantities
Red/Black/Blue, 60 cm (24 in) 4
Specifications
Parameter Value
Three-Phase Shielded Cable Characteristics
Number of Conductors per Cable 3 (shield not included)
Cross Section 1 mm² (1974 cmil)
Rated Current 8A
Rated Voltage 600 V
Length 1m
Three-Phase Shielded Cable Quantities 2
Shielded Cables Terminated with Stacking 2 mm
Banana Plugs Characteristics
Number of Conductors per Cable 4 (shield not included)
Cross Section 0.324 mm² (640 cmils)
Rated Current 2.2 A
Rated Voltage 30 V ac / 60 V dc
Length 0.9 m
Shielded Cables Terminated with Stacking 2 mm
Banana Plugs Quantities
Shielded Cables Terminated with Stacking 2 mm
2
Banana Plug Leads Quantities
Specifications
Parameter Value
4 mm Safety Banana Plug Leads Characteristics
Cross Section 1 mm² (1974 cmil)
Rated Current 19 A
Rated Voltage 600 V, CAT II
4 mm Safety Banana Plug Leads Quantities
White, 15 cm (6 in) 60
Yellow, 30 cm (12 in) 26
Red, 60 cm (24 in) 38
Blue, 90 cm (36 in) 8
2 mm Safety Banana Plug Leads Characteristics
Cross Section 0.5 mm² (987 cmils)
Rated Current 10 A
Rated Voltage 30 V ac / 60 V dc
2 mm Safety Banana Plug Leads Quantities
White, 15 cm (6 in) 4
Software
Model
Qty Description
number
1 Complete Function Set ___________________________________________________________ 581435 (8968-00)
1 Standard Functions (computer-based control) Set _____________________________________ 581437 (896820)
1 Turbine Emulator Function Set _____________________________________________________ 579783 (896830)
1 Lead-Acid Battery Charger Function Set _____________________________________________ 581438 (896840)
1 Ni-MH Battery Charger Function Set ________________________________________________ 581439 (896850)
1 Solar Panel Emulator Function Set __________________________________________________ 581440 (896860)
1 Software Development Kit (SDK) _________________________________________________ 581441 (896870) 238
Model
Qty Description
number
1 SCADA for LVDAC-EMS ________________________________________________________ 8094377 (8973-00) 239
Specifications
Parameter Value
Power Requirements
Maximum Current 6A
AC Power Network Installation 120 V - 60 Hz, must include live, neutral, and ground wires
Maximum Leakage Current 1.8 mA
Dynamometer Mode
Magnetic Torque 0 to 3 N·m (0 to 27 lbf·in)
Direction of Rotation CW / CCW
Speed 0 to 2500 r/min
Nominal Power 350 W
Power Supply Mode
DC Voltage 0 to ± 150 V
AC Voltage (RMS) 0 to 105 V (no-load)
DC Current 0 to ± 5 A
AC Current (RMS) 0 to 3.5 A
Maximum Output Power 500 W
AC Frequency 10 to 120 Hz
Control Functions
Activated Set Standard Functions (Manual Control), Model 8968-1
Liquid-Crystal Display (LCD) 76 mm (3 in), monochrome, background-illuminated, 240 x 160 dots
Control Inputs
Command Input 0 to ± 10 V
Thermistor Input 10 kΩ, type 1
Control Outputs
Shaft Encoder Quadrature encoder (A-B) - 360 pulses/revolution - TTL compatible
Torque Output Sensitivity 0.3 N·m/V (2.655 lbf·in/V)
Speed Output Sensitivity 500 r/min/V
Communication Port
Type USB 2.0
Physical Characteristics
Dimensions (H x W x D) 308 x 287 x 437 mm (12.1 x 11.3 x 17.2 in)
Net Weight 19.5 kg (43.0 lb)
Specifications
Parameter Value
Control Functions
Control Functions Two-Quadrant, Constant-Torque Brake
Clockwise Prime Mover/Brake
Counterclockwise Prime Mover/Brake
Clockwise Constant-Speed Prime Mover/Brake
Counterclockwise Constant-Speed Prime Mover/Brake
Positive Constant-Torque Prime Mover/Brake
Negative Constant-Torque Prime Mover/Brake
Positive Voltage Source
Negative Voltage Source
Positive Current Source
Negative Current Source
50 Hz Power Source
60 Hz Power Source
200 V DC Bus
Lead-Acid Battery Float Charger
Two-Quadrant, Constant-Torque Brake
Torque 0-3 N·m (26.55 lbf·in)
Clockwise/Counterclockwise Prime Mover/Brake
Speed 0-2500 r/min
Clockwise/Counterclockwise Constant-Speed Prime
Mover/Brake
Speed 0-2500 r/min
Positive/Negative Constant-Torque Prime Mover/
Brake
Torque 0-3 N·m (26.55 lbf·in)
Positive/Negative Voltage Source
Voltage 0 to ±150 V
Positive/Negative Current Source
Current 0 to ±5 A
50 Hz/60 Hz Power Source
No-Load Voltage 0-140 V
200 V DC Bus
Status On or off
Lead-Acid Battery Float Charger
Float Voltage 0-150 V
Specifications
Parameter Value
Dynamometer Mode
Magnetic Torque 0 to 3 N·m (0 to 27 lbf·in)
Direction of Rotation CW / CCW
Speed 0 to 2500 r/min
Nominal Power 350 W
Power Supply Mode
240 Refer to the Computer Requirements in the System Specifications section of this datasheet if the computer is to be provided by the end-user.
Parameter Value
DC Voltage 0 to ± 150 V
AC Voltage (RMS) 0 to 105 V (no-load)
DC Current 0 to ± 5 A
AC Current (RMS) 0 to 3.5 A
Maximum Output Power 500 W
AC Frequency 10 to 120 Hz
Control Functions
Activated Sets Standard Functions (Manual Control), Model 8968-1
Standard Functions (Computer-Based Control), Model 8968-2
Liquid-Crystal Display (LCD) 76 mm (3 in), monochrome, background-illuminated, 240 x 160 dots
Control Inputs
Command Input 0 to ± 10 V
Thermistor Input 10 kΩ, type 1
Control Outputs
Shaft Encoder Quadrature encoder (A-B) - 360 pulses/revolution - TTL compatible
Torque Output Sensitivity 0.3 N·m/V (2.655 lbf·in/V)
Speed Output Sensitivity 500 r/min/V
Communication Port USB 2.0
Power Requirements 120 V - 6 A - 60 Hz, must include live, neutral, and ground wires
A currently available personal computer with USB 2.0 ports, running under one of the following operating
Computer Requirements
systems: Windows® 7 or Windows® 8.
Physical Characteristics
Dimensions (H x W x D) 308 x 287 x 490 mm (12.1 x 11.3 x 19.3 in)
Net Weight 19.5 kg (43.0 lb)
• Speed Sweep
Specifications
Parameter Value
Control Functions
Control Functions Two-Quadrant, Constant-Torque Brake
Clockwise Prime Mover/Brake
Counterclockwise Prime Mover/Brake
Clockwise Constant-Speed Prime Mover/Brake
Counterclockwise Constant-Speed Prime Mover/Brake
Positive Constant-Torque Prime Mover/Brake
Negative Constant-Torque Prime Mover/Brake
Four-Quadrant, Constant-Speed Prime Mover/Brake
Speed Sweep
Mechanical Load
Positive Voltage Source
Negative Voltage Source
DC Voltage Source
Positive Current Source
Negative Current Source
DC Current Source
50 Hz Power Source
60 Hz Power Source
AC Power Source
Lead-Acid Battery Float Charger
Two-Quadrant, Constant-Torque Brake
Torque Control Software knob, 8960 module knob, or 8960 command input
Torque 0-3 N·m (26.55 lbf·in)
Pulley Ratio 24:24, 24:12, or 24:32
Clockwise/Counterclockwise Prime Mover/Brake
Speed Control Software knob, 8960 module knob, or 8960 command input
Speed 0-2500 r/min
Pulley Ratio 24:24, 24:12, or 24:32
Clockwise/Counterclockwise Constant-Speed Prime
Mover/Brake
Speed Control Software knob, 8960 module knob, or 8960 command input
Speed 0-2500 r/min
Pulley Ratio 24:24, 24:12, or 24:32
Positive/Negative Constant-Torque Prime Mover/
Brake
Parameter Value
Torque Control Software knob, 8960 module knob, or 8960 command input
Torque 0-3 N·m (26.55 lbf·in)
Pulley Ratio 24:24, 24:12, or 24:32
Four-Quadrant, Constant-Speed Prime Mover/Brake
Speed Control Software knob, 8960 module knob, or 8960 command input
Speed 0-2500 r/min
Pulley Ratio 24:24, 24:12, or 24:32
Speed Sweep
Start Speed -3000 r/min to 3000 r/min
Finish Speed -3000 r/min to 3000 r/min
Number of Steps 0-50 steps
Step Duration 2-10 s
Record Data to Table Yes or no
Pulley Ratio 24:24, 24:12, or 24:32
Mechanical Load
Load Type Flywheel, fan, grinder, conveyor, calender, crane, user defined
Inertia 0.005-1 kg·m² (0.119-23.73 lb·ft²)
Friction Torque 0.05-3 N·m (0.44-26.55 lbf·in)
Pulley Ratio 24:24, 24:12, or 24:32
Positive/Negative Voltage Source
Voltage Control Software knob, 8960 module knob, or 8960 command input
Voltage 0 V to 147 V / -147 V to 0 V
DC Voltage Source
Voltage Control Software knob, 8960 module knob, or 8960 command input
Voltage -147 V to 147 V
Positive/Negative Current Source
Current Control Software knob, 8960 module knob, or 8960 command input
Current 0 A to 5 A / -5 A to 0 A
DC Current Source
Current Control Software knob, 8960 module knob, or 8960 command input
Current -5 A to 5 A
50 Hz/60 Hz Power Source
Voltage Control Software knob, 8960 module knob, or 8960 command input
No-Load Voltage 0-140 V
AC Power Source
No-Load Voltage 0-140 V
DC Offset Correction -1000 to 1000
Frequency 10-100 Hz
Lead-Acid Battery Float Charger
Float Voltage 0-150 V
In each operating mode, key parameters related to the selected function are displayed. Speed, torque,
mechanical power, and energy are displayed in the Dynamometer mode while voltage, current, electrical power,
and energy are displayed in the Power Supply mode. Optional functions, such as a small wind-turbine emulator,
a hydraulic turbine emulator, a solar panel emulator, battery chargers, an SDK (Software Development Kit) etc.,
can be added to the standard functions to further enhance the training possibilities of the Four-Quadrant
Dynamometer/Power Supply.
Two modes are available to control the function which the Four-Quadrant Dynamometer/Power Supply
performs: Manual and Computer-Based.
In the Manual control mode, the module operates as a stand-alone unit, and the function performed is selected,
set, and monitored using front-panel mounted controls and display. This mode provides access to all basic
functions. In the Computer-Based control mode, the function performed by the module is selected, set, and
monitored using the LVDAC-EMS software. In this mode, communication between the Four-Quadrant
Dynamometer/Power Supply and the host computer running the LVDAC-EMS software is achieved through a
USB connection. This mode provides access to all basic functions, as well as to additional advanced functions.
Model 8960-D includes the Four-Quadrant Dynamometer/Power Supply, Model 8960-3, with the following
function sets activated:
Specifications
Parameter Value
Dynamometer Mode
Magnetic Torque 0 to 3 N·m (0 to 27 lbf·in)
Direction of Rotation CW / CCW
Speed 0 to 2500 r/min
Nominal Power 350 W
Power Supply Mode
DC Voltage 0 to ± 150 V
AC Voltage (RMS) 0 to 105 V (no-load)
DC Current 0 to ± 5 A
AC Current (RMS) 0 to 3.5 A
Maximum Output Power 500 W
AC Frequency 10 to 120 Hz
Control Functions
Activated Sets Standard Functions (Manual Control), Model 8968-1
Standard Functions (Computer-Based Control), Model 8968-2
Turbine Emulator, Model 8968-3
Lead-Acid Battery Charger, Model 8968-4
Liquid-Crystal Display (LCD) 76 mm (3 in), monochrome, background-illuminated, 240 x 160 dots
Control Inputs
241 Refer to the Computer Requirements in the System Specifications section of this datasheet if the computer is to be provided by the end-user.
Parameter Value
Command Input 0 to ± 10 V
Thermistor Input 10 kΩ, type 1
Control Outputs
Shaft Encoder Quadrature encoder (A-B) - 360 pulses/revolution - TTL compatible
Torque Output Sensitivity 0.3 N·m/V (2.655 lbf·in/V)
Speed Output Sensitivity 500 r/min/V
Communication Port USB 2.0
Power Requirements 120 V - 6 A - 60 Hz, must include live, neutral, and ground wires
A currently available personal computer with USB 2.0 ports, running under one of the following operating
Computer Requirements
systems: Windows® 7 or Windows® 8.
Physical Characteristics
Dimensions (H x W x D) 308 x 287 x 490 mm (12.1 x 11.3 x 19.3 in)
Net Weight 19.5 kg (43.0 lb)
• Small Wind-Turbine Emulator: this function makes the permanent-magnet dc motor of the Four-
Quadrant Dynamometer/Power Supply faithfully reproduce the effect of wind on the bladed rotor of a
small-scale wind turbine. The torque-speed characteristic at the shaft of the machine coupled to the
Four-Quadrant Dynamometer/Power Supply is the same as the one that is obtained when wind blows
at a certain speed on the rotor of the actual wind turbine. The user has control over the wind speed and
air density.
• Hydraulic Turbine Emulator: this function uses the permanent-magnet dc motor of the Four-Quadrant
Dynamometer/Power Supply to recreate the behavior of an hydraulic turbine with a synchronous
generator. The torque-speed characteristics at the shaft of the machine coupled to the Four-Quadrant
Dynamometer/Power Supply is the same as that of a Francis-type hydraulic turbine. The user has
control over the vane angle (manually or through the module analog input), the vane variation speed,
and the inertia.
Specifications
Parameter Value
Control Functions
Control Functions Wind-Turbine Emulator
Hydraulic-Turbine Emulator
Wind-Turbine Emulator
Wind Control Software slider or 8960 command input
Parameter Value
Wind Speed 3-12 m/s (6.7-26.8 mph)
Air Density 1.12-1.44 kg/m³ (0.07-0.09 lb/ft³)
Wind Turbine Type 1.15 m with 3 blades, 1.15 m with 3 blades and gearbox, 0.72 m with 3 blades and passive stall
Pulley Ratio 24:24, 24:12, 24:32 (different pulley ratios are available depending on the wind turbine type)
Inertia J 0.02-0.4 kg·m² (0.475-9.492 lb·ft²) (only available for certain wind turbine types)
Gear Ratio R 0.5-2 (only available for certain wind turbine types)
Hydraulic-Turbine Emulator
Vane Control Software slider or 8960 command input
Turbine Type 300 W Francis
Vane Maximal Speed 0-100%/s
Runner Inertia 0.005-1 kg·m² (7.119 lb·ft²)
Pulley Ratio 24:24
This function uses the four-quadrant power supply to implement a battery charger that is able to rapidly charge
lead-acid batteries of various capacities (typically in less than two hours). A three-step charge algorithm is
used. Battery charging starts with a constant current corresponding to the battery maximum charge current
until the battery gassing voltage is reached. At this point, battery charging continues with a constant voltage
(close to gassing voltage) until the charge current decreases to 0.1 C. Then, constant-voltage charging
continues but at a lower voltage (float charging voltage). The user has to specify the following four battery
characteristics for the charger to achieve proper charge control: maximum charge current, gassing voltage, 0.1C
current (10% of battery capacity), and float charging voltage. The function indicates the voltage, current,
electrical power, and energy at the charger output. The function can also indicate battery temperature when the
temperature sensor of the battery (if so equipped) is connected to the Thermistor Input of the Four-Quadrant
Dynamometer/Power Supply. The function can also indicate battery temperature when the temperature sensor
of the battery (if so equipped) is connected to the Thermistor Input of the Four-Quadrant Dynamometer/Power
Supply. The license for the Lead-Acid Battery Charger, Model 8968-4, is required to activate the Lead-Acid
Battery Charger (Fast) function in the Four-Quadrant Dynamometer/Power Supply.
This function uses the four-quadrant power supply to sink a constant current from a battery, thereby discharging
the battery at a specific rate, during a specific period. The discharger also monitors the battery voltage during
discharge. Battery discharging terminates immediately when the battery voltage decreases to a specific cutoff
voltage. The user has to specify the discharge current, discharge duration, and cutoff voltage for the discharger
to achieve proper discharge control. The function indicates the voltage, current, electrical power, and energy at
the discharger output. The function can also indicate battery temperature when the temperature sensor of the
battery (if so equipped) is connected to the Thermistor Input of the Four-Quadrant Dynamometer/Power Supply.
The Battery Discharger function is perfectly suited to measure discharge characteristics of batteries at various
rates as well as to bring a battery to a specific depth of discharge before a battery charging experiment. The
license for the Lead-Acid Battery Charger, Model 8968-4, or the license for the Ni-MH Battery Chargers, Model
8968-5, is required to activate the Battery Discharger (Contant-Current Timed Discharge with Voltage Cutoff )
function in the Four-Quadrant Dynamometer/Power Supply.
Specifications
Parameter Value
Control Functions
Control Functions Lead-Acid Battery Charger (Fast)
Battery Discharger (Constant-Current Timed Discharge with Voltage Cutoff )
Lead-Acid Battery Charger (Fast)
Maximum Charge Current 0-5 A
Gassing Voltage 0-150 V
0.1C Current 0-5 A
Float Voltage 0-150 V
Battery Discharger (Constant-Current Timed Discharge
with Voltage Cutoff )
Discharge Current 0-5 A
Discharge Duration 0-2000 min
Cutoff Voltage 0-150 V
functions. In the Computer-Based control mode, the function performed by the module is selected, set, and
monitored using the LVDAC-EMS software. In this mode, communication between the Four-Quadrant
Dynamometer/Power Supply and the host computer running the LVDAC-EMS software is achieved through a
USB connection. This mode provides access to all basic functions, as well as to additional advanced functions.
Model 8960-E includes the Four-Quadrant Dynamometer/Power Supply, Model 8960-3, with the following
function sets activated:
Specifications
Parameter Value
Dynamometer Mode
Magnetic Torque 0 to 3 N·m (0 to 27 lbf·in)
Direction of Rotation CW / CCW
Speed 0 to 2500 r/min
Nominal Power 350 W
Power Supply Mode
DC Voltage 0 to ± 150 V
AC Voltage (RMS) 0 to 105 V (no-load)
DC Current 0 to ± 5 A
AC Current (RMS) 0 to 3.5 A
Maximum Output Power 500 W
AC Frequency 10 to 120 Hz
Control Functions
Activated Sets Standard Functions (Manual Control), Model 8968-1
Standard Functions (Computer-Based Control), Model 8968-2
Lead-Acid Battery Charger, Model 8968-4
Liquid-Crystal Display (LCD) 76 mm (3 in), monochrome, background-illuminated, 240 x 160 dots
Control Inputs
Command Input 0 to ± 10 V
Thermistor Input 10 kΩ, type 1
Control Outputs
Shaft Encoder Quadrature encoder (A-B) - 360 pulses/revolution - TTL compatible
Torque Output Sensitivity 0.3 N·m/V (2.655 lbf·in/V)
Speed Output Sensitivity 500 r/min/V
Communication Port USB 2.0
Power Requirements 120 V - 6 A - 60 Hz, must include live, neutral, and ground wires
A currently available personal computer with USB 2.0 ports, running under one of the following operating
Computer Requirements
systems: Windows® 7 or Windows® 8.
Physical Characteristics
Dimensions (H x W x D) 308 x 287 x 490 mm (12.1 x 11.3 x 19.3 in)
Net Weight 19.5 kg (43.0 lb)
242 Refer to the Computer Requirements in the System Specifications section of this datasheet if the computer is to be provided by the end-user.
Specifications
Parameter Value
Dynamometer Mode
243 Refer to the Computer Requirements in the System Specifications section of this datasheet if the computer is to be provided by the end-user.
Parameter Value
Magnetic Torque 0 to 3 N·m (0 to 27 lbf·in)
Direction of Rotation CW / CCW
Speed 0 to 2500 r/min
Nominal Power 350 W
Power Supply Mode
DC Voltage 0 to ± 150 V
AC Voltage (RMS) 0 to 105 V (no-load)
DC Current 0 to ± 5 A
AC Current (RMS) 0 to 3.5 A
Maximum Output Power 500 W
AC Frequency 10 to 120 Hz
Control Functions
Activated Sets Standard Functions (Manual Control), Model 8968-1
Standard Functions (Computer-Based Control), Model 8968-2
Turbine Emulator, Model 8968-3
Lead-Acid Battery Charger, Model 8968-4
Solar Panel Emulator, Model 8968-6
Liquid-Crystal Display (LCD) 76 mm (3 in), monochrome, background-illuminated, 240 x 160 dots
Control Inputs
Command Input 0 to ± 10 V
Thermistor Input 10 kΩ, type 1
Control Outputs
Shaft Encoder Quadrature encoder (A-B) - 360 pulses/revolution - TTL compatible
Torque Output Sensitivity 0.3 N·m/V (2.655 lbf·in/V)
Speed Output Sensitivity 500 r/min/V
Communication Port USB 2.0
Power Requirements 120 V - 6 A - 60 Hz, must include live, neutral, and ground wires
A currently available personal computer with USB 2.0 ports, running under one of the following operating
Computer Requirements
systems: Windows® 7 or Windows® 8.
Physical Characteristics
Dimensions (H x W x D) 308 x 287 x 490 mm (12.1 x 11.3 x 19.3 in)
Net Weight 19.5 kg (43.0 lb)
Specifications
Parameter Value
Control Functions Solar Panel Emulator
Solar Panel Emulator
Solar Irradiance Control Software slider or 8960 command input
Solar Irradiance 1-1000 W/m²
Number of PV Modules in Series 1-7 modules
Number of PV Modules in Parallel 5-45 modules
Model Variants
The Four-Quadrant Dynamometer/Power Supply is available in several model variants. Each variant consists of
the Four-Quadrant Dynamometer/Power Supply, Model 8960-3, plus a unique combination of functions pre-
activated in the module. The model variants currently available are listed in the following table. Other model
variants will be added as they become available.
Model 8960-B is the basic variant of the Four-Quadrant Dynamometer/Power Supply and is designed to operate
as a stand-alone unit (no computer required). It includes all standard functions available in the Manual control
mode only (Model 8968-1). Model 8960-B is a direct replacement for the older Prime Mover / Dynamometer,
Model 8960-1, used in the 0.2 kW Computer-Assisted Electromechanical Training System, Model 8006.
Model 8960-C is a step-up variant that includes all standard functions available in the Manual control mode
(Model 8968-1) plus all standard functions available in the Computer-Based control mode (Model 8968-2).
Model 8960-C is the minimal variant that allows the addition of optional functions required to perform certain
courses in the Electric Power Technology Training Program, Series 8010. For instance, Model 8960-D consists of
the Four-Quadrant Dynamometer/Power Supply, Model 8960-C, plus the licenses for the Turbine Emulator,
Model 8968-3, and the Lead-Acid Battery Charger, Model 8968-4, which are required to perform several lab
exercises in the Basic Renewable Energy Training System, Model 8010-5.
Model 8960-A is the fully equipped variant including all optional functions currently available for the Four-
Quadrant Dynamometer/Power Supply.
Four-Quadrant Dynamometer/Power Supply modules with a specific combination of pre-activated optional
functions other than those listed above can also be ordered. To order a customized Four-Quadrant
Dynamometer/Power Supply, request Model 8960-C and add each desired optional function (8968-X).
LVDAC-EMS Software
The LVDAC-EMS software is a freeware which can be downloaded from website www.labvolt.com. It is a user-
friendly tool that facilitates the use of the various functions which can be implemented with USB peripherals
such as the Four-Quadrant Dynamometer/Power Supply, Model 8960-3, and the Data Acquisition and Control
Interface, Model 9063.
The LVDAC-EMS software also includes a firmware update for the Four-Quadrant Dynamometer/Power Supply.
When a Four-Quadrant Dynamometer/Power Supply is connected to a newer version of LVDAC-EMS, the user
can easily update the module using a simple update wizard.
Using LVDAC-EMS with the Four-Quadrant Dynamometer/Power Supply provides access to the basic functions
available in the Manual control mode plus a broad selection of advanced functions not available in the Manual
control mode. Furthermore, extra information is provided for each control function. All parameters related to the
function performed by the Four-Quadrant Dynamometer/Power Supply can be monitored using the computer-
based instruments in LVDAC-EMS and exported to the LVDAC-EMS Data Table and Graph tool for further
analysis.
Module Functions
The Four-Quadrant Dynamometer/Power Supply can perform a wide variety of functions in each of the two
operating modes (Dynamometer and Power Supply). The standard functions available in each operating mode
are described below. A table at the end of this section lists the standard functions available in each of the two
control modes (Manual and Computer-Based).
Mechanical Load
Speed Sweep
This function uses the permanent-
magnet dc machine to make the
machine coupled to the Four-Quadrant
Dynamometer/Power Supply (i.e., the
machine under test) rotate at various
speeds within a specific range, in a
certain number of steps and in a
certain time interval. Closed-loop
control is used to ensure accurate
speed sweep. The speed sweep
performed is defined entirely by the
user with only four parameters (start
speed, end speed, number of steps,
and step duration). The function
indicates the speed, torque,
mechanical power, and energy
measured at the shaft of the machine
under test. The function can also indicate the machine temperature when the temperature sensor of the
machine under test (if so equipped) is connected to the Thermistor Input of the Four-Quadrant Dynamometer/
Power Supply. The Speed Sweep function is useful to measure how parameters related to the machine under
test vary as a function of the rotation speed. The parameters measured throughout the speed sweep can be
recorded to a data table automatically.
DC Voltage Source
This function uses the four-quadrant
power supply to implement a DC
voltage source having either positive
or negative polarity. The source can
either source or sink current no matter
if the source voltage polarity is
positive or negative (four-quadrant
operation). A voltage command
entered by the user determines the
polarity and value of the source
voltage. The function indicates the
voltage, current, electrical power, and
energy at the source output. The
function can also indicate circuit
temperature (e.g., battery
temperature) when a temperature
sensor is connected to the Thermistor
Input of the Four-Quadrant Dynamometer/Power Supply.
DC Current Source
This function uses the four-quadrant
power supply to implement a DC
current source that either sources
current (positive polarity) or sinks
current (negative polarity) at its
output. The polarity of the voltage
across the source can be either
positive or negative no matter the
direction of the source current (four-
quadrant operation). A current
command entered by the user
determines the direction (polarity) and
value of the source current. The
function indicates the voltage, current,
electrical power, and energy at the
source output. The function can also
indicate circuit temperature (e.g.,
battery temperature) when a temperature sensor is connected to the Thermistor Input of the Four-Quadrant
Dynamometer/Power Supply.
50 Hz Power Source
This function uses the four-quadrant
power supply to implement a non-
regulated variable-voltage 50 Hz
power source. A voltage command
entered by the user determines the
rms value of the "no-load" source
voltage. The source can either source
or sink current no matter if the source
voltage polarity (instantaneous) is
positive or negative (four-quadrant
operation). The function indicates the
circuit temperature (e.g., transformer
core temperature) when a temperature
sensor is connected to the Thermistor
Input of the Four-Quadrant
Dynamometer/Power Supply.
60 Hz Power Source
Same as the 50 Hz Power Source
function except for the frequency.
AC Power Source
This function uses the four-quadrant
power supply to implement a non-
regulated variable-voltage, variable-
frequency AC power source. The
source can either source or sink
current no matter if the source voltage
polarity (instantaneous) is positive or
negative (four-quadrant operation).
Voltage and frequency commands
entered by the user determine the rms
value and frequency of the "no-load"
source voltage. The function indicates
the circuit temperature (e.g.,
transformer core temperature) when a
temperature sensor is connected to
the Thermistor Input of the Four-
Quadrant Dynamometer/Power
Supply.
200 V DC Bus
This function uses the four-quadrant
power supply to implement a fixed-
voltage dc bus of 200 V. The dc bus
can either source or sink current (two-
quadrant operation). The function
indicates the voltage, current, and
power at the source output.
Ni-MH Battery Charger (Constant-Current Charge with Voltage Cutoff and TCO), Model 8968-5
This function uses the four-quadrant
power supply to implement a basic Ni-
MH battery charger. This charger
forces a constant charge (current value
of 0.1C or less) in the battery until the
battery voltage reaches a certain value
at which the charge terminates. The
charger also monitors the battery
temperature during charge. Battery
charging is terminated immediately
when the battery temperature reaches
a specific cutoff temperature. The user
has to specify the charge current,
cutoff voltage, and cutoff temperature for the charger to achieve proper charge control. The function indicates
the voltage, current, electrical power, and energy at the charger output as well as the battery temperature. This
method of charging Ni-MH batteries is the slowest one but requires less surveillance. The license for the Ni-MH
Battery Chargers, Model 8968-5, is required to activate the Ni-MH Battery Charger (Constant-Current Charge
with Voltage Cutoff and TCO) function in the Four-Quadrant Dynamometer/Power Supply.
Ni-MH Battery Charger (Constant-Current Timed Charge with TCO), Model 8968-5
This function uses the four-quadrant
power supply to implement a time-
controlled Ni-MH battery charger. This
charger forces a constant charge
current in the battery during a specific
period of time and then turns off. The
charger also monitors the battery
temperature during charge. Battery
charging is terminated immediately
when the battery temperature reaches
a specific cutoff temperature. The user
has to specify the charge current,
charge duration, and cutoff temperature for the charger to achieve proper charge control. The function indicates
the voltage, current, electrical power, and energy at the charger output as well as the battery temperature. The
license for the Ni-MH Battery Chargers, Model 8968-5, is required to activate the Ni-MH Battery Charger
(Constant-Current Timed Charge with TCO) function in the Four-Quadrant Dynamometer/Power Supply.
Ni-MH Battery Charger (Constant-Current Charge with -dV and TCO), Model 8968-5
This function uses the four-quadrant
power supply to implement an
advanced Ni-MH battery charger. This
charger forces a constant charge
current in the battery until the battery
voltage, which increases steadily from
the beginning of charge, reaches a
plateau and decreases by a certain
amount (-dV), at which point the
charge terminates. The charger also
monitors the battery temperature
during charge. Battery charging is
terminated immediately when the
battery temperature reaches a specific cutoff temperature. The user has to specify the charge current, voltage
drop (-dV), and cutoff temperature for the charger to achieve proper charge control. The function indicates the
voltage, current, electrical power, and energy at the charger output as well as the battery temperature. The
license for the Ni-MH Battery Chargers, Model 8968-5, is required to activate the Ni-MH Battery Charger
(Constant-Current Charge with -dV and TCO) function in the Four-Quadrant Dynamometer/Power Supply.
Ni-MH Battery Charger (Constant-Current Charge with dT°/dt and TCO), Model 8968-5
This function uses the four-quadrant
power supply to implement an
advanced Ni-MH battery charger. This
charger monitors the battery
temperature and forces a constant
charge current in the battery until the
rate of increase of the battery
temperature (dT°/dt) reaches a
specific value, at which point the
charge terminates. Battery charging
can also terminate when the battery
temperature reaches a specific cutoff
temperature. The user has to specify
the charge current, maximum rate of temperature increase (dT°/dt), and cutoff temperature for the charger to
achieve proper charge control. The function indicates the voltage, current, electrical power, and energy at the
charger output as well as the battery temperature. The license for the Ni-MH Battery Chargers, Model 8968-5, is
required to activate the Ni-MH Battery Charger (Constant-Current Charge with dT°/dt and TCO) function in the
Four-Quadrant Dynamometer/Power Supply.
Battery Discharger (Constant-Current Timed Discharge with Voltage Cutoff ), Model 8968-4 or Model
8968-5
This function uses the four-quadrant
power supply to sink a constant
current from a battery, thereby
discharging the battery at a specific
rate, during a specific period. The
discharger also monitors the battery
voltage during discharge. Battery
discharging terminates immediately
when the battery voltage decreases to
a specific cutoff voltage. The user has
to specify the discharge current,
discharge duration, and cutoff voltage for the discharger to achieve proper discharge control. The function
indicates the voltage, current, electrical power, and energy at the discharger output. The function can also
indicate battery temperature when the temperature sensor of the battery (if so equipped) is connected to the
Thermistor Input of the Four-Quadrant Dynamometer/Power Supply. The Battery Discharger function is perfectly
suited to measure discharge characteristics of batteries at various rates as well as to bring a battery to a
specific depth of discharge before a battery charging experiment. The license for the Lead-Acid Battery Charger,
Model 8968-4, or the license for the Ni-MH Battery Chargers, Model 8968-5, is required to activate the Battery
Discharger (Constant-Current Timed Discharge with Voltage Cutoff ) function in the Four-Quadrant
Dynamometer/Power Supply.
• Voltage Control
• Current Control
• AC Power Source
Important note: A Software Development Kit must be ordered for each Four-Quadrant Dynamometer/Power
Supply, Model 8960-3, to unlock the SDK features.
Topic Coverage
• State-of-the-art, multipurpose device combining power supply, prime mover, dynamometer, metering
and emulator properties
• USB port computer-based mode allows the user to completely control every function directly from the
computer
• Supports learning of electromechanical and renewable energy
• Can be connected with other EMS equipment to enhance the training possibilities
Optional Equipment
Model
Qty Description
number
1 SCADA for LVDAC-EMS __________________________________________________________ 8094377 (8973-00)
Manual
Manual
Description
number
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
Optional Equipment
Model
Qty Description
number
1 AC 24 V Wall Mount Power Supply _______________________________________________ 579696 (3000420) 245
244 Refer to the Computer Requirements in the System Specifications section of this datasheet if the computer is to be provided by the end-user.
Only one computer is required per station. This model is available in multiple voltage- and frequency dependent variants. Contact a Festo
representative to obtain the correct part number.
245 Required if power is not supplied by the Power Supply, Model 8821-2. This model is available in multiple voltage- and frequency dependent
Manual
Manual
Description
number
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
Software
Model
Qty Description
number
1 SCADA for LVDAC-EMS ________________________________________________________ 8094377 (8973-00) 247
1 Complete Function Set ___________________________________________________________ 581451 (9069-00)
1 Chopper/Inverter Control Function Set ______________________________________________ 581453 (906920)
1 Thyristor Control Function Set _____________________________________________________ 581454 (906930)
1 Home Energy Production Control Function Set ________________________________________ 581455 (906940)
1 Three-Phase PWM Rectifier/Inverter Control Function Set _______________________________ 581456 (906950)
1 BLDC Motor/PMSM Control Function Set ____________________________________________ 581457 (906960)
1 High-Voltage DC (HVDC) Transmission System Control Function Set ______________________ 579790 (906970)
1 Static Var Compensator (SVC) Control Function Set ____________________________________ 581458 (906980)
1 Software Development Kit (SDK) _________________________________________________ 581459 (906990) 248
1 Synchronous Generator Control Function Set _________________________________________ 579788 (9069A0)
1 Static Synchronous Compensator (STATCOM) Control Function Set _______________________ 581460 (9069B0)
1 Synchroscope Function ___________________________________________________________ 579789 (9069C0)
1 Doubly-Fed Induction Generator (DFIG) Control Function Set ____________________________ 587056 (9069D0)
1 Power Line Series Compensation Function Set ________________________________________ 581461 (9069S0)
Specifications
Parameter Value
Insulated Voltage Inputs (4)
Range (Low / High Scales) -80 to +80 V / -800 to + 800 V (user-selectable through software)
Impedance (Low / High Scales) 326.6 kΩ / 3.25 MΩ
Bandwidth DC to 65 kHz (-3 dB)
Accuracy 1% (dc to 10 kHz)
Insulation 800 V
Maximum Voltage (Any Terminal vs GND) 283 V ac / 400 V dc
Measurement Category CAT II (283 V ac/400 V dc versus ground)
246 Not required if another 24 VAC source is included, such as the variable three-phase power supply.
247 Software allowing the monitoring of up to 5 Stations through OPC.
248 For MatLab, LabView, etc.
Parameter Value
Insulated Current Inputs (4)
Range (Low / High Scales) -4 to +4 A / -40 to + 40 A (25 A rms)
Impedance (Low / High Scales) 5 mΩ / 50 mΩ
Bandwidth DC to 65 kHz (-3 dB)
Accuracy 1% (dc to 10 kHz)
Insulation 800 V
Maximum Voltage (Any Terminal vs GND) 283 V ac / 400 V dc
Measurement Category CAT II (283 V ac/400 V dc versus ground)
Analog Inputs (8)
Voltage Range -10 to +10 V
Impedance > 10 MΩ
Bandwidth DC to 125 kHz
Measured Parameters User-selectable through software
Parameter-to-Voltage Ratio User-determined through software
A/D Converter for Insulated and Analog Inputs (16)
Type Successive approximation
Resolution 12 bits
Integral Non-Linearity ≤ ±1.5 LSB
Differential Non-Linearity ≤ ±1 LSB
Maximum Sampling Rate 600 ksamples/s (one channel)
FIFO Buffer Size 16 ksamples
Analog Outputs (2)
Voltage Range -10 to +10 V
Operational Load Impedance > 600 Ω
D/A Converter for Analog Outputs (2)
Type Resistor string
Resolution 12 bits
Integral Non-Linearity ≤ ±8 LSB
Differential Non-Linearity -0.5 to +0.7 LSB
Digital Inputs (3)
Types Encoder (2), synchronization (1)
Signal Level 0-5 V (TTL compatible)
Maximum Input Frequency 50 kHz
Impedance 5 kΩ
Digital Outputs (9)
Types Control (6 on a DB9 connector and 2 on 2 mm banana jacks), synchronization (1 on a DB9 connector)
Signal Level 0-5 V (TTL compatible)
Maximum Output Frequency 20 kHz (software-limited)
Impedance 200 Ω
Control Functions
Activated Set Computer-Based Instrumentation Function, Model 9069-1
Computer I/O Interface USB 2.0 full speed via type-B receptacle
Power Requirements 24 V - 0.4 A - 50/60 Hz
Accessories
Included Accessories 2 m USB interconnection cable (1)
24 V power cable (1)
2 mm banana plug test leads (3)
DB9 connector control cable (1)
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 3.9 kg (8.6 lb)
Acquisition functions
581452 (906910)
The Computer-Based Instrumentation
Function Set, Model 9069-1, includes the
following computer-based instruments:
• Metering
• Data Table and Graph
• Oscilloscope
• Phasor Analyzer
• Harmonic Analyzer
Specifications
Parameter Value
Metering
Number of Meters 18
Sampling Window 266.7 ms or user adjusted through software (11.4-819 ms)
Sampling Frequency (each meter) 7.68 kHz or user adjusted through software (2.5-179.2 kHz)
Display Type Digital or analog, user selectable through software
Oscilloscope
Number of Channels 8
Vertical Sensitivity 2-500 V/div.
Time Base 0.0001-10 s/div.
Sampling Window 20 x selected time base (software triggering) / 10 x selected time base (hardware triggering)
Sampling Frequency 512 samples per measured parameter per horizontal sweep, up to a maximum of 512 kHz
Phasor Analyzer
Voltage Sensitivity 2-200 V/div.
Current Sensitivity 0.1-5 A/div.
Sampling Window 2-409 ms
Sampling Frequency (Each Phasor) 5-102.4 kHz
Harmonic Analyzer
Fundamental-Frequency Range 1-1400 Hz
Number of Harmonic Components 5 to 40, user selectable through software
Vertical Scale (Relative Scale) 0.1-10%/div.
Vertical Scale (Absolute Scale) 0.1-50 V/div., 0.01-10 A/div.
Sampling Window 10 ms to 1 s
Sampling Frequency 16-102 kHz
Manual
Manual
Description
number
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
249 Refer to the Computer Requirements in the System Specifications section of this datasheet if the computer is to be provided by the end-user.
Only one computer is required per station. This model is available in multiple voltage- and frequency dependent variants. Contact a Festo
representative to obtain the correct part number.
Model
Qty Description
number
1 AC 24 V Wall Mount Power Supply _______________________________________________ 579696 (3000420) 250
Specifications
Parameter Value
Insulated Voltage Inputs (4)
Range (Low / High Scales) -80 to +80 V / -800 to + 800 V (user-selectable through software)
Impedance (Low / High Scales) 326.6 kΩ / 3.25 MΩ
Bandwidth DC to 65 kHz (-3 dB)
Accuracy 1% (dc to 10 kHz)
Insulation 800 V
Measurement Category CAT II (283 V ac/400 V dc versus ground)
Insulated Current Inputs (4)
Range (Low / High Scales) -4 to +4 A / -40 to + 40 A (25 A rms)
Impedance (Low / High Scales) 5 mΩ / 50 mΩ
Bandwidth DC to 65 kHz (-3 dB)
Accuracy 1% (dc to 10 kHz)
Insulation 800 V
Measurement Category CAT II (283 V ac/400 V dc versus ground)
Analog Inputs (8)
Voltage Range -10 to +10 V
Impedance > 10 MΩ
Bandwidth DC to 125 kHz
Measured Parameters User-selectable through software
Parameter-to-Voltage Ratio User-determined through software
A/D Converter for Insulated and Analog Inputs (16)
Type Successive approximation
Resolution 12 bits
Integral Non-Linearity ≤ ±1.5 LSB
Differential Non-Linearity ≤ ±1 LSB
Maximum Sampling Rate 600 ksamples/s (one channel)
FIFO Buffer Size 16 ksamples
Analog Outputs (2)
Voltage Range (2) -10 to +10 V
Operational Load Impedance > 600 Ω
D/A Converter for Analog Outputs (2)
Type Resistor string
Resolution 12 bits
Integral Non-Linearity ≤ ±8 LSB
Differential Non-Linearity -0.5 to +0.7 LSB
Digital Inputs (3)
Types Encoder (2), synchronization (1)
Signal Level 0-5 V (TTL compatible)
Maximum Input Frequency 50 kHz
Impedance 5 kΩ
Digital Outputs (9)
Types Control (6 on a DB9 connector and 2 on 2 mm banana jacks), synchronization (1 on a DB9 connector)
Signal Level 0-5 V (TTL compatible)
Maximum Output Frequency 20 kHz (software-limited)
Impedance 200 Ω
Control Functions
Activated Sets Computer-Based Instrumentation Function, Model 9069-1
Chopper/Inverter Control Function Set, Model 9069-2
Computer I/O Interface USB 2.0 full speed via type-B receptacle
Power Requirements 24 V - 0.4 A - 50/60 Hz
250 Required if power is not supplied by the Power Supply, Model 8821-2. This model is available in multiple voltage- and frequency dependent
Parameter Value
Accessories
Included Accessories 2 m USB interconnection cable (1)
24 V power cable (1)
2 mm banana plug test leads (3)
DB9 connector control cable (1)
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 3.9 kg (8.6 lb)
Specifications
Parameter Value
Control Functions
Control Functions Buck Chopper (high-side switching)
Buck Chopper (low-side switching)
Buck/Boost Chopper
Boost Chopper
Four-Quadrant Chopper
Buck Chopper with Feedback
Boost Chopper with Feedback
Single-Phase, 180° Modulation Inverter
Single-Phase PWM Inverter
Three-Phase, 180° Modulation Inverter
Three-Phase PWM Inverter
Three-Phase PWM Inverter (constant V/f ratio)
Insulated DC-to-DC Converter
Four-Quadrant DC Motor Drive without Current Control
Parameter Value
Four-Quadrant DC Motor Drive
Buck Chopper (high-side switching), Buck Chopper
(low-side switching), Buck/Boost Chopper, Boost
Chopper, Four-Quadrant Chopper
Switching Frequency 400 Hz to 20 kHz
Duty Cycle Control Knob or analog input on the DACI
Duty Cycle 0-100%
Acceleration Time (0 to Max. Voltage) 0-100 s
Deceleration Time (Max. Voltage to 0) 0-100 s
IGBTs Q1 to Q6 PWM, on, off (certain IGBTs are unavailable depending on the selected chopper control function)
Buck Chopper with Feedback, Boost Chopper with
Feedback
Switching Frequency 2-20 kHz
Command Input Knob or analog input on the DACI
Command 0-100%
Feedback Input Voltage, current, speed, power, or low-power analog signal
Feedback Filter Cutoff Frequency 100-4900 Hz
Feedback Range (100% Value =) 10-400 V
Acceleration Time (0 to 100%) 0-100 s
Deceleration Time (100% to 0) 0-100 s
Single-Phase, 180° Modulation Inverter
DC Bus Unipolar or bipolar
Frequency 0-120 Hz
IGBTs Q1 to Q6 180° Modulation, on, or off (certain IGBTs are unavailable)
Single-Phase PWM Inverter
DC Bus Unipolar or bipolar
Switching Frequency 400 Hz to 20 kHz
Frequency 0-120 Hz
Peak Voltage 0-100% of dc bus
IGBTs Q1 to Q6 PWM, on, or off (certain IGBTs are unavailable)
Three-Phase, 180° Modulation Inverter
Phase Sequence Forward (1-2-3), reverse (1-3-2), or forward/reverse
Frequency 0-120 Hz
IGBTs Q1 to Q6 180° Modulation, on, or off
Three-Phase PWM Inverter
Switching Frequency 400 Hz to 20 kHz
Phase Sequence Forward (1-2-3), reverse (1-3-2), or forward/reverse
Frequency 0-120 Hz
Peak Voltage 0-117% of dc bus/2
Modulation Type Sinusoidal pulse-width modulation or space vector
IGBTs Q1 to Q6 PWM, on, or off
Three-Phase PWM Inverter (Constant V/f Ratio)
Switching Frequency 400 Hz to 20 kHz
Phase Sequence Forward (1-2-3), reverse (1-3-2), or forward/reverse
Frequency 0-120°
Knee Peak Voltage 0-117% of dc bus voltage/2
Knee Frequency 1-120 Hz
Modulation Type Sinusoidal pulse-width modulation or space vector
Acceleration Time (0 to Knee) 0-100 s
Deceleration Time (Knee to 0) 0-100 s
Insulated DC-to-DC Converter
Duty Cycle 0-45%
Parameter Value
Four-Quadrant DC Motor Drive with and without
Current Control
Switching Frequency 2-20 kHz
Speed Command Input Knob or analog input on the DACI
Speed Command -5000 r/min to 5000 r/min
Pulley Ratio 24:12 or 24:24
Acceleration Time (0 to Max. Speed) 0-100 s
Deceleration Time (Max. Speed to 0) 0-100 s
Current Feedback Range 4 A or 40 A (only available in current control)
Current Feedback Filter Cutoff Frequency 100-4900 Hz (only available in current control)
Current Command Limit 0-40 A (only available in current control)
Manual
Manual
Description
number
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
Specifications
Parameter Value
Insulated Voltage Inputs (4)
Range (Low / High Scales) -80 to +80 V / -800 to + 800 V (user-selectable through software)
Impedance (Low / High Scales) 326.6 kΩ / 3.25 MΩ
Bandwidth DC to 65 kHz (-3 dB)
Accuracy 1% (dc to 10 kHz)
Insulation 800 V
Measurement Category CAT II (283 V ac/400 V dc versus ground)
Insulated Current Inputs (4)
Range (Low / High Scales) -4 to +4 A / -40 to + 40 A (25 A rms)
Impedance (Low / High Scales) 5 mΩ / 50 mΩ
Bandwidth DC to 65 kHz (-3 dB)
Accuracy 1% (dc to 10 kHz)
Insulation 800 V
Measurement Category CAT II (283 V ac/400 V dc versus ground)
Analog Inputs (8)
Voltage Range -10 to +10 V
Impedance > 10 MΩ
Bandwidth DC to 125 kHz
Measured Parameters User-selectable through software
Parameter-to-Voltage Ratio User-determined through software
A/D Converter for Insulated and Analog Inputs (16)
Type Successive approximation
Resolution 12 bits
Integral Non-Linearity ≤ ±1.5 LSB
Differential Non-Linearity ≤ ±1 LSB
Maximum Sampling Rate 600 ksamples/s (one channel)
FIFO Buffer Size 16 ksamples
Analog Outputs (2)
Voltage Range (2) -10 to +10 V
Operational Load Impedance > 600 Ω
D/A Converter for Analog Outputs (2)
Type Resistor string
Resolution 12 bits
Integral Non-Linearity ≤ ±8 LSB
Differential Non-Linearity -0.5 to +0.7 LSB
Digital Inputs (3)
Types Encoder (2), synchronization (1)
Signal Level 0-5 V (TTL compatible)
Maximum Input Frequency 50 kHz
Impedance 5 kΩ
Digital Outputs (9)
251 Refer to the Computer Requirements in the System Specifications section of this datasheet if the computer is to be provided by the end-user.
Only one computer is required per station. This model is available in multiple voltage- and frequency dependent variants. Contact a Festo
representative to obtain the correct part number.
252 Required if power is not supplied by the Power Supply, Model 8821-2. This model is available in multiple voltage- and frequency dependent
Parameter Value
Types Control (6 on a DB9 connector and 2 on 2 mm banana jacks), synchronization (1 on a DB9 connector)
Signal Level 0-5 V (TTL compatible)
Maximum Output Frequency 20 kHz (software-limited)
Impedance 200 Ω
Control Functions
Activated Sets Computer-Based Instrumentation Function, Model 9069-1
Chopper/Inverter Control Function Set, Model 9069-2
Thyristor Control Function Set, Model 9069-3
Computer I/O Interface USB 2.0 full speed via type-B receptacle
Power Requirements 24 V - 0.4 A - 50/60 Hz
Accessories
Included Accessories 2 m USB interconnection cable (1)
24 V power cable (1)
2 mm banana plug test leads (3)
DB9 connector control cable (1)
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 3.9 kg (8.6 lb)
Specifications
Parameter Value
Control Functions
Control Functions Thyristor Single-Phase Half-Wave Rectifier
Thyristor Single-Phase Bridge
Thyristor Three-Phase Bridge
Thyristor Three-Phase Bridge with Feedback
Solid-State Relay
Thyristor Single-Phase AC Power Control
Thyristor Three-Phase AC Power Control
Direct-On-Line Starter
Soft Starter
Thyristor Single-Phase Half-Wave Rectifier, Thyristor
Single-Phase Bridge, Thyristor Three-Phase Bridge
Firing Angle Control Knob or analog input on the DACI
Firing Angle 0-180°
Acceleration Time (0 to Max. Voltage) 0-100 s
Deceleration Time (Max. Voltage to 0) 0-100 s
Thyristors Q1 to Q6 Active, on, or off (certain thyristors are unavailable depending on the selected thyristor control function)
Thyristor Three-Phase Bridge with Feedback
Command Input On or off
Command Knob or analog input on the DACI
Inverter Limit 100-180°
Arc-Cosine On or off
Feedback Input Voltage, rms voltage, current, speed, power, or low-power analog signal
Feedback Range (Voltage Input Only) 80-800 V
Current Feedback Range (Current Input Only) 0.4-4 A
Speed Feedback Range (Speed Input Only) 250-2500 r/min
Analog Feedback Range (Analog Input Only) 1-10 V
Power Feedback Range (Power Input Only) 32-3200 W
Feedback Filter Cutoff Frequency 10-180 Hz
Acceleration Time (0 to 100%) 0-100 s
Deceleration Time (100% to 0) 0-100 s
Thyristors Q1 to Q6 Active, on, or off
Solid-State Relay
Zero-Voltage Switching On or off
Relay Control Open or close
Thyristors Q1 to Q6 Active, on, or off (certain thyristors are unavailable)
Thyristor Single-Phase AC Power Control
Control Mode Phase control, synchronous burst fire control, or asynchronous burst fire control
Firing Angle Control Knob or analog input on the DACI
Firing Angle 0-180°
Thyristors Q1 to Q6 Active, on, or off (certain thyristors are unavailable)
Thyristor Three-Phase AC Power Control
Load Configuration 3 wires star (3S), 3 wires delta (3D), 4 wires star (4S), or 6 wires delta (6D)
Phase control or synchronous burst fire control (certain control modes are unavailable depending on the selected
Control Mode
thyristor control function)
Firing Angle Control Knob or analog input on the DACI
Acceleration Time (0 to Max. Voltage) 0-100 s
Deceleration Time (Max. Voltage to 0) 0-100 s
Thyristors Q1 to Q6 Active, on, or off
Direct-On-Line Starter
Motor Full-Load Current 0.4-2 A
Overload On or off
Overload Class 5, 10, 15, 20, 25, 30, 35, or 40
Soft Starter
Mode Soft Start or current-limit start
Motor Full-Load Current 0.4-2 A
Initial Torque 15%, 25%, 35%, or 65% of LRT
Start Time 2-200 s
Parameter Value
Kick-Start Time 0 s, 0.5 s, 1 s, or 1.5 s
Soft Stop 0, 1, 2, or 3 times the start time
Overload On or off
Overload Class 5, 10, 15, 20, 25, 30, 35, or 40
Manual
Manual
Description
number
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
Specifications
Parameter Value
Insulated Voltage Inputs (4)
Range (Low / High Scales) -80 to +80 V / -800 to + 800 V (user-selectable through software)
Impedance (Low / High Scales) 326.6 kΩ / 3.25 MΩ
Bandwidth DC to 65 kHz (-3 dB)
Accuracy 1% (dc to 10 kHz)
Insulation 800 V
Measurement Category CAT II (283 V ac/400 V dc versus ground)
Insulated Current Inputs (4)
Range (Low / High Scales) -4 to +4 A / -40 to + 40 A (25 A rms)
Impedance (Low / High Scales) 5 mΩ / 50 mΩ
Bandwidth DC to 65 kHz (-3 dB)
Accuracy 1% (dc to 10 kHz)
Insulation 800 V
Measurement Category CAT II (283 V ac/400 V dc versus ground)
Analog Inputs (8)
Voltage Range -10 to +10 V
Impedance > 10 MΩ
Bandwidth DC to 125 kHz
Measured Parameters User-selectable through software
Parameter-to-Voltage Ratio User-determined through software
A/D Converter for Insulated and Analog Inputs (16)
Type Successive approximation
Resolution 12 bits
Integral Non-Linearity ≤ ±1.5 LSB
Differential Non-Linearity ≤ ±1 LSB
Maximum Sampling Rate 600 ksamples/s (one channel)
FIFO Buffer Size 16 ksamples
Analog Outputs (2)
Voltage Range (2) -10 to +10 V
Operational Load Impedance > 600 Ω
D/A Converter for Analog Outputs (2)
Type Resistor string
Resolution 12 bits
Integral Non-Linearity ≤ ±8 LSB
Differential Non-Linearity -0.5 to +0.7 LSB
Digital Inputs (3)
Types Encoder (2), synchronization (1)
Signal Level 0-5 V (TTL compatible)
Maximum Input Frequency 50 kHz
Impedance 5 kΩ
Digital Outputs (9)
Types Control (6 on a DB9 connector and 2 on 2 mm banana jacks), synchronization (1 on a DB9 connector)
Signal Level 0-5 V (TTL compatible)
253 Refer to the Computer Requirements in the System Specifications section of this datasheet if the computer is to be provided by the end-user.
Only one computer is required per station. This model is available in multiple voltage- and frequency dependent variants. Contact a Festo
representative to obtain the correct part number.
254 Required if power is not supplied by the Power Supply, Model 8821-2. This model is available in multiple voltage- and frequency dependent
Parameter Value
Maximum Output Frequency 20 kHz (software-limited)
Impedance 200 Ω
Control Functions
Activated Sets Computer-Based Instrumentation Function, Model 9069-1
Chopper/Inverter Control Function Set, Model 9069-2
Home Energy Production Control Function Set, Model 9069-4
Computer I/O Interface USB 2.0 full speed via type-B receptacle
Power Requirements 24 V - 0.4 A - 50/60 Hz
Accessories
Included Accessories 2 m USB interconnection cable (1)
24 V power cable (1)
2 mm banana plug test leads (3)
DB9 connector control cable (1)
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 3.9 kg (8.6 lb)
Specifications
Parameter Value
Control Functions
Control Functions Single-Phase Stand-Alone Inverter
Single-Phase Grid-Tied Inverter
Single-Phase Grid-Tied Inverter (LF Transformer)
Solar/Wind Power Inverter (HF Transformer)
Single-Phase Stand-Alone Inverter Function
Output Power Limit 50-250 W
Battery Minimum Voltage 35-55 V
PWM Inverter Peak Output Voltage 50-95% of dc bus voltage
PWM Inverter Output Frequency 50 or 60 Hz
DC Bus Voltage Command 100-400 V
Single-Phase Grid-Tied Inverter Function
Active Current Command -2 to 2 A
Reactive Current Command -2 to 2 A
DC Bus Voltage Command 100-400 V
Solar Power Inverter (LF Transformer)
MPP Tracker On or off
Active Current Command -10 A to 10 A (only available when the MPP Tracker parameter is switched to Off )
Reactive Current Command -10 A to 10 A
Solar/Wind Power Inverter (HF Transformer)
MPP Tracker Type Solar panel or wind turbine
Manual
Manual
Description
number
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
Specifications
Parameter Value
Insulated Voltage Inputs (4)
Range (Low / High Scales) -80 to +80 V / -800 to + 800 V (user-selectable through software)
Impedance (Low / High Scales) 326.6 kΩ / 3.25 MΩ
Bandwidth DC to 65 kHz (-3 dB)
Accuracy 1% (dc to 10 kHz)
Insulation 800 V
Measurement Category CAT II (283 V ac/400 V dc versus ground)
Insulated Current Inputs (4)
Range (Low / High Scales) -4 to +4 A / -40 to + 40 A (25 A rms)
Impedance (Low / High Scales) 5 mΩ / 50 mΩ
Bandwidth DC to 65 kHz (-3 dB)
Accuracy 1% (dc to 10 kHz)
Insulation 800 V
Measurement Category CAT II (283 V ac/400 V dc versus ground)
Analog Inputs (8)
Voltage Range -10 to +10 V
Impedance > 10 MΩ
Bandwidth DC to 125 kHz
Measured Parameters User-selectable through software
Parameter-to-Voltage Ratio User-determined through software
A/D Converter for Insulated and Analog Inputs (16)
Type Successive approximation
Resolution 12 bits
Integral Non-Linearity ≤ ±1.5 LSB
Differential Non-Linearity ≤ ±1 LSB
Maximum Sampling Rate 600 ksamples/s (one channel)
FIFO Buffer Size 16 ksamples
Analog Outputs (2)
Voltage Range (2) -10 to +10 V
Operational Load Impedance > 600 Ω
D/A Converter for Analog Outputs (2)
Type Resistor string
Resolution 12 bits
Integral Non-Linearity ≤ ±8 LSB
255 Refer to the Computer Requirements in the System Specifications section of this datasheet if the computer is to be provided by the end-user.
Only one computer is required per station. This model is available in multiple voltage- and frequency dependent variants. Contact a Festo
representative to obtain the correct part number.
256 Required if power is not supplied by the Power Supply, Model 8821-2. This model is available in multiple voltage- and frequency dependent
Parameter Value
Differential Non-Linearity -0.5 to +0.7 LSB
Digital Inputs (3)
Types Encoder (2), synchronization (1)
Signal Level 0-5 V (TTL compatible)
Maximum Input Frequency 50 kHz
Impedance 5 kΩ
Digital Outputs (9)
Types Control (6 on a DB9 connector and 2 on 2 mm banana jacks), synchronization (1 on a DB9 connector)
Signal Level 0-5 V (TTL compatible)
Maximum Output Frequency 20 kHz (software-limited)
Impedance 200 Ω
Control Functions
Activated Sets Computer-Based Instrumentation Function, Model 9069-1
Synchroscope Function, Model 9069-C
Computer I/O Interface USB 2.0 full speed via type-B receptacle
Power Requirements 24 V - 0.4 A - 50/60 Hz
Accessories
Included Accessories 2 m USB interconnection cable (1)
24 V power cable (1)
2 mm banana plug test leads (3)
DB9 connector control cable (1)
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 3.9 kg (8.6 lb)
Synchroscope Function
579789 (9069C0)
The Synchroscope Function is used for the synchronization
of synchronous generators. This function emulates the
operation of an actual synchroscope by showing on-screen
the dial indicating the phase angle difference between the
generator voltage and the network voltage. In addition, the
Synchroscope Function includes meters displaying various
parameters important to generator synchronization (e.g.,
network voltage and frequency, generator voltage and
frequency, voltage difference).
Specifications
Parameter Value
Monitored Values (in Addition to Phase Difference
Dial)
Monitored Values (in Addition to Phase Difference Dial) Network voltage
Network frequency
Generator voltage
Generator frequency
Voltage difference
Manual
Manual
Description
number
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
257 Refer to the Computer Requirements in the System Specifications section of this datasheet if the computer is to be provided by the end-user.
Only one computer is required per station. This model is available in multiple voltage- and frequency dependent variants. Contact a Festo
representative to obtain the correct part number.
Model
Qty Description
number
1 AC 24 V Wall Mount Power Supply _______________________________________________ 579696 (3000420) 258
Specifications
Parameter Value
Insulated Voltage Inputs (4)
Range (Low / High Scales) -80 to +80 V / -800 to + 800 V (user-selectable through software)
Impedance (Low / High Scales) 326.6 kΩ / 3.25 MΩ
Bandwidth DC to 65 kHz (-3 dB)
Accuracy 1% (dc to 10 kHz)
Insulation 800 V
Measurement Category CAT II (283 V ac/400 V dc versus ground)
Insulated Current Inputs (4)
Range (Low / High Scales) -4 to +4 A / -40 to + 40 A (25 A rms)
Impedance (Low / High Scales) 5 mΩ / 50 mΩ
Bandwidth DC to 65 kHz (-3 dB)
Accuracy 1% (dc to 10 kHz)
Insulation 800 V
Measurement Category CAT II (283 V ac/400 V dc versus ground)
Analog Inputs (8)
Voltage Range -10 to +10 V
Impedance > 10 MΩ
Bandwidth DC to 125 kHz
Measured Parameters User-selectable through software
Parameter-to-Voltage Ratio User-determined through software
A/D Converter for Insulated and Analog Inputs (16)
Type Successive approximation
Resolution 12 bits
Integral Non-Linearity ≤ ±1.5 LSB
Differential Non-Linearity ≤ ±1 LSB
Maximum Sampling Rate 600 ksamples/s (one channel)
FIFO Buffer Size 16 ksamples
Analog Outputs (2)
Voltage Range (2) -10 to +10 V
Operational Load Impedance > 600 Ω
D/A Converter for Analog Outputs (2)
Type Resistor string
Resolution 12 bits
Integral Non-Linearity ≤ ±8 LSB
Differential Non-Linearity -0.5 to +0.7 LSB
Digital Inputs (3)
Types Encoder (2), synchronization (1)
Signal Level 0-5 V (TTL compatible)
Maximum Input Frequency 50 kHz
Impedance 5 kΩ
Digital Outputs (9)
Types Control (6 on a DB9 connector and 2 on 2 mm banana jacks), synchronization (1 on a DB9 connector)
Signal Level 0-5 V (TTL compatible)
Maximum Output Frequency 20 kHz (software-limited)
Impedance 200 Ω
Control Functions
Activated Sets Computer-Based Instrumentation Function, Model 9069-1
Thyristor Control Function Set, Model 9069-3
Home Energy Production Control Function Set, Model 9069-4
HVDC Transmission System Control Function Set, Model 9069-7
258 Required if power is not supplied by the Power Supply, Model 8821-2. This model is available in multiple voltage- and frequency dependent
Parameter Value
SVC Control Function Set, Model 9069-8
STATCOM Control Function Set, Model 9069-B
Computer I/O Interface USB 2.0 full speed via type-B receptacle
Power Requirements 24 V - 0.4 A - 50/60 Hz
Accessories
Included Accessories 2 m USB interconnection cable (1)
24 V power cable (1)
2 mm banana plug test leads (3)
DB9 connector control cable (1)
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 3.9 kg (8.6 lb)
Specifications
Parameter Value
Control Functions
Control Functions Dual Thyristor Bridge
Monopolar HVDC Transmission System
12-Pulse Converter
Dual Thyristor Bridge
Control Type Independent, common (α,α), or common (α,ß)
Acceleration Time (0 to Max. Voltage) 0-100 s
Deceleration Time (Max. Voltage to 0) 0-100 s
Firing Angle Control (for Each Bridge) Knob or analog input on the DACI
Firing Angle (for Each Bridge) 0-180°
Monopolar HVDC Transmission System
Control Type Independent, linked (rectifier = bridge 1), or linked (rectifier = bridge 2)
Command Input (for Each Bridge) Knob or analog input on the DACI
Current Command (for Each Bridge) 0-2 A
Inverter Limit (for Each Bridge) 90-180°
Arc-Cosine (for Each Bridge) On of off
Feedback Filter Cutoff Frequency (for Each Bridge) 10-180 Hz
Parameter Value
12-Pulse Converter
Firing Angle 0-180°
Acceleration Time (0 to Max. Voltage) 0-100 s
Deceleration Time (Max. Voltage to 0) 0-100 s
Specifications
Parameter Value
Control Modes
Control Modes Manual control
Automatic voltage control
Automatic reactive power control
Manual Control
TCR Firing Angle 0-180°
TSC 1 and TSC 2 Switched in or switched out
Automatic Voltage Control
Line Voltage Command 90-150 V
Automatic Reactive Power Control
Phase Adjustment -90° to 90°
Specifications
Parameter Value
Control Modes
Control Modes Automatic Voltage Control
Automatic Reactive Power Control
Automatic Voltage Control
DC Bus Voltage Command 150-250 V
AC Bus Line Voltage Command 58-108 V
Phase Adjustment -90° to 90°
Automatic Reactive Power Control
DC Bus Voltage Command 150-250 V
Phase Adjustment -90 to 90°
Manual
Manual
Description
number
Computer-Based Instruments for EMS (User Guide) ______________________________________ 585219 (86718E0)
Specifications
Parameter Value
Insulated Voltage Inputs (4)
Range (Low / High Scales) -80 to +80 V / -800 to + 800 V (user-selectable through software)
Impedance (Low / High Scales) 326.6 kΩ / 3.25 MΩ
Bandwidth DC to 65 kHz (-3 dB)
Accuracy 1% (dc to 10 kHz)
Insulation 800 V
Measurement Category CAT II (283 V ac/400 V dc versus ground)
Insulated Current Inputs (4)
Range (Low / High Scales) -4 to +4 A / -40 to + 40 A (25 A rms)
Impedance (Low / High Scales) 5 mΩ / 50 mΩ
Bandwidth DC to 65 kHz (-3 dB)
Accuracy 1% (dc to 10 kHz)
Insulation 800 V
Measurement Category CAT II (283 V ac/400 V dc versus ground)
Analog Inputs (8)
Voltage Range -10 to +10 V
Impedance > 10 MΩ
Bandwidth DC to 125 kHz
Measured Parameters User-selectable through software
Parameter-to-Voltage Ratio User-determined through software
A/D Converter for Insulated and Analog Inputs (16)
Type Successive approximation
Resolution 12 bits
Integral Non-Linearity ≤ ±1.5 LSB
Differential Non-Linearity ≤ ±1 LSB
Maximum Sampling Rate 600 ksamples/s (one channel)
FIFO Buffer Size 16 ksamples
Analog Outputs (2)
Voltage Range (2) -10 to +10 V
Operational Load Impedance > 600 Ω
D/A Converter for Analog Outputs (2)
Type Resistor string
Resolution 12 bits
Integral Non-Linearity ≤ ±8 LSB
Differential Non-Linearity -0.5 to +0.7 LSB
Digital Inputs (3)
Types Encoder (2), synchronization (1)
Signal Level 0-5 V (TTL compatible)
Maximum Input Frequency 50 kHz
Impedance 5 kΩ
Digital Outputs (9)
259 Refer to the Computer Requirements in the System Specifications section of this datasheet if the computer is to be provided by the end-user.
Only one computer is required per station. This model is available in multiple voltage- and frequency dependent variants. Contact a Festo
representative to obtain the correct part number.
260 Required if power is not supplied by the Power Supply, Model 8821-2. This model is available in multiple voltage- and frequency dependent
Parameter Value
Types Control (6 on a DB9 connector and 2 on 2 mm banana jacks), synchronization (1 on a DB9 connector)
Signal Level 0-5 V (TTL compatible)
Maximum Output Frequency 20 kHz (software-limited)
Impedance 200 Ω
Control Functions
Activated Sets Computer-Based Instrumentation Function, Model 9069-1
Thyristor Control Function Set, Model 9069-3
HVDC Transmission System Control Function Set, Model 9069-7
SVC Control Function Set, Model 9069-8
STATCOM Control Function Set, Model 9069-B
Computer I/O Interface USB 2.0 full speed via type-B receptacle
Power Requirements 24 V - 0.4 A - 50/60 Hz
Accessories
Included Accessories 2 m USB interconnection cable (1)
24 V power cable (1)
2 mm banana plug test leads (3)
DB9 connector control cable (1)
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 3.9 kg (8.6 lb)
Specifications
Parameter Value
Control Modes
Control Modes Three-Phase, Six-Step 120° Modulation Inverter
Brushless DC Motor
Permanent Magnet Synchronous Motor Drive
Wind Turbine with Permanent Magnet Synchronous Generator
Three-Phase, Six-Step 120° Modulation Inverter
Phase Sequence Forward (1-2-3) or reverse (1-3-2)
Frequency 0-400 Hz
IGBTs Q1 to Q6 Six-step 120° modulation, on, or off
Brushless DC Motor
Control Mode Six-step 120° modulation or low-side six-step PWM
Direction of Rotation Forward or reverse
Permanent Magnet Synchronous Motor Drive
Control Mode Constant V/f ratio or vector control
Switching Frequency 400 Hz to 20 kHz
Parameter Value
Direction of Rotation Forward or reverse
Frequency 0-300 Hz
Knee Peak Voltage 0-100% of dc bus voltage/2
Knee Frequency 1-300 Hz
Low-Speed Boost Voltage 0-25% of dc bus voltage/2
Modulation Type Sinusoidal pulse-width modulation or space vector
Acceleration Time (0 to Knee) 0-100 s
Deceleration Time (Knee to 0) 0-100 s
Wind Turbine with Permanent Magnet Synchronous
Generator - First Module (BLDC Motor/PMSM Control)
Switching Frequency 400 Hz to 20 kHz
Direction of Rotation Forward or reverse
MPP Tracker On or off
Vector Control Direct Current Command 0-5 A
Vector Control Quadrature Current Limit 0-3.5 A
Wind Turbine with Permanent Magnet Synchronous
Generator - Second Module (PWM Rectifier/Inverter
Control)
DC Bus Voltage Command 150-250 V
PWM Rectifier/Inverter Reactive Current Command -1.5 A to 1.5 A
PWM Rectifier/Inverter Phase Adjustment -90° to 90°
Important Notice: One DACI SDK (Software Development Kit) must be ordered for each Data Acquisition and
Control Interface to unlock the SDK features.
Specifications
Parameter Value
Control Functions
Control Functions Hydropower generator (dead bus - balanced load)
Hydropower generator (infinite bus)
Hydropower generator (balanced infinite bus)
Hydropower generator (gen. paralleling - balanced bus)
Each function of the Synchronous Generator Control Function Set comprises a synchro-check relay, a speed
Controller Features
governor, and an automatic voltage regulator.
Synchro-Check Relay
Live Bus Voltage Threshold 50-100 V
Voltage Difference 2-40 V
Frequency Difference 0.02-2 Hz
Phase Difference 5-50°
Circuit-Breaker Operate Time 0.05-0.25 s
Relay Output Normal, high, or low
Dead Bus Voltage Threshold 10-80% of nominal voltage
Dead Time 0.1-20 s
Speed Governor
Speed Command 0-2000 r/min
Speed Droop 0-10%
Generator Acceleration 10-100 r/min/s
Automatic Voltage Regulator (AVR)
Generator Voltage Command 0-240 V
Voltage Droop 0-10%
Thyristor Bridge Firing Control Mode Automatic or manual
Minimum Firing Angle Limit 40-120°
Maximum Firing Angle Limit 120°
Specifications
Parameter Value
Power Requirements
Maximum Current 0.75 A
AC Power Network Installation 120 V – 50/60 Hz, must include live, neutral, and ground wires
Power Outputs
Fixed, Single-Phase AC 24 V – 2,5 A
Specifications
Parameter Value
Hydrogen Cylinder Connection Kit
Description One-stage hydrogen pressure regulator
Max. Inlet Pressure 200 bar
Max. Outlet Pressure 17 bar
Connection CGA, DIN, or BS
Specifications
Parameter Value
Storage Capacity (at a Charge Pressure of 17 bar) 250 Nl
Output 1.7 sl/min
Charge Pressure 10-17 bar
Charge Time One hour at normal ambient temperature and with active cooling
Module Installation
The EMS modules are guided into position along stainless steel guide rails. Separators between each bay of the
workstation ensure perfect alignment of the EMS modules and allow their easy insertion in the workstation. A
holding mechanism ensures that each EMS module stays in place once it is installed in a compartment of the
workstation. Front-mounted push levers allow all EMS modules on a single row to be released for easy removal.
Additional Information
Six holes in the rear panel of the workstation allow connection to a power supply, as well as the connection of 2
kW machines to their interconnection modules. Assembly of the workstation before painting ensures that each
EMS module in the workstation is correctly grounded.
Manual
Manual
Description
number
Electric Power Technology Training Equipment (User Guide) ________________________________ 584778 (38486E0)
Optional Equipment
Model
Qty Description
number
1 Industrial Controls Single-Rail Workstation _________________________________________ 581243 (3105A0) 261
1 Industrial Controls Double-Rail Workstation ________________________________________ 585964 (3105B0) 262
1 Mounting Frame (DIN A4) for EMS Workstations _____________________________________ 8138160 (8136PC)
1 All-in-One Touch Screen Computer (including Monitor Stand with Articulating Arm) _________ 8108708 (8990A0)
1 External Shelf for the Mobile Workstation _________________________________________ 581465 (36653-00) 263
1 Mounting Stand with Articulating Arm _____________________________________________ 8108710 (36653A0)
261 This add-on workstation allows modules from the Industrial Controls Training Systems, Models 8036, to be installed in the EMS workstation.
Specifications
Parameter Value
Physical Characteristics
Intended Location On the floor (stands on casters)
Dimensions (H x W x D) 1660 x 935 x 665 mm (65.4 x 36.8 x 26.2 in)
Net Weight 77.1 kg (170 lb)
Specifications
Parameter Value
Available space
Length available for modules 860 mm
Compatibility DIN A4 (for modules with a height of 297 mm) - Fits three(3) modules with a standard width of 266 mm
Physical Characteristics
Dimensions (H x W x D) 390 x 930 x 340 mm
Optional Equipment
Model
Qty Description
number
1 Dust Cover for EMS Storage Cabinet ________________________________________________ 587006 (8992-00)
Specifications
Parameter Value
Physical Characteristics
Intended Location On the floor and attached to a wall
Dimensions (H x W x D) 1980 x 1225 x 480 mm (78 x 48.2 x 18.9 in)
Net Weight TBE
Specifications
Parameter Value
Physical Characteristics
Dimensions (H x W x D) 308 x 287 x 415 mm (12.1 x 11.3 x 16.3 in)
Net Weight TBE
Specifications
Parameter Value
Physical Characteristics
Parameter Value
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight TBE
DC Motor/Generator (Optional)
579759 (8211-00)
The DC Motor/Generator is a dc machine mounted in a full-size
EMS module. It can operate independently as a dc motor or a dc
generator. The armature, shunt field, and series field windings
are terminated separately on the faceplate to permit long and
short shunt as well as cumulatively and differentially
compounded motor and generator connections. This machine is
fitted with exposed movable brushes to allow students to study
the effect of armature reaction and commutation while the
machine is operating under load.
An independent, circuit-breaker protected, shunt-field rheostat
is mounted on the faceplate for motor speed control or
generator output voltage adjustment. The speed of the DC
Motor/Generator can be controlled using the Thyristor Speed
Controller in both the open-loop and closed-loop modes of
control.
Specifications
Parameter Value
Rating
Motor Output Power 175 W
Generator Output Power 120 W
Armature Voltage 120 V dc
Shunt Field Voltage 120 V dc
Full-Load Speed 1800 r/min
Full-Load Motor Current 2.8 A
Full-Load Generator Current 1A
Physical Characteristics
Dimensions (H x W x D) 308 x 287 x 445 mm (12.1 x 11.3 x 17.5 in)
Net Weight 14.1 kg (31 lb)
Specifications
Parameter Value
Wind Turbine Type Direct drive, fixed-pitch three blade rotor
Blade Radius 62.2 cm (24.5 in)
Nacelle Length 67.6 cm (26.6 in)
Physical Characteristics
Dimensions (H x W x D) 1800 x 991 x 991 mm (71.0 x 39.0 x 39.0 in)
Net Weight 21.8 kg (48 lb)
Specifications
Parameter Value
Rating
Line Voltage 120 V
Mechanical Power 175 W
Full-Load Speed 1715 r/min
Full-Load Current 4.6 A
Physical Characteristics
Dimensions (H x W x D) 308 x 287 x 420 mm (12.1 x 11.3 x 16.5 in)
Net Weight 13.8 kg (30.4 lb)
Specifications
Parameter Value
Rating
Voltage 120 V ac/dc
Mechanical Power 175 W
Full-Load Speed 1800 r/min
Full-Load Current 3A
Physical Characteristics
Dimensions (H x W x D) 308 x 287 x 420 mm (12.1 x 11.3 x 16.5 in)
Net Weight 14.4 kg (31.7 lb)
Specifications
Parameter Value
Output
Power 20 W
Voltage 12 V
Short Circuit Current 1.29 A
Open Circuit Voltage 21.6 V
Physical Characteristics
Dimensions 620 x 442 x 108 mm (24.4 x 17.4 x 4.25 in)
Net Weight 5 kg (11 lbs)
Specifications
Parameter Value
Hydrogen Production 30 sl/h
Power Consumption 450 VA
Hydrogen Purity 7.0 (99.99999%)
Hydrogen Pressure 12 bar
Power Input 100/240 V – 50/60 Hz
Physical Characteristics
Dimensions (H x W x D) 178 x 241 x 400 mm (7 x 9.5 x 15.75 in)
Net Weight 22 kg (48.5 lb)
Specifications
Parameter Value
Voltage
Ranges 0-600 V ac/dc
Current
Range 0-10 A ac/dc
Resistance
Range 0-40 MΩ
Physical Characteristics
Dimensions (H x W x D) 182 x 90 x 45 mm (7.17 x 3.54 x 1.77 in)
Net Weight 354 g (0.78 lb)
Specifications
Parameter Value
Multimeters
Quantity 3
Voltage Range 0-600 V dc and ac
Current Range 0-10 A dc
Resistance Range 0-20 MΩ
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
Parameter Value
Net Weight TBE
Specifications
Parameter Value
4 mm Safety Banana Plug Leads Characteristics
Cross Section 1 mm² (1974 cmil)
Rated Current 19 A
Rated Voltage 600 V, CAT II
4 mm Safety Banana Plug Leads Quantities
Yellow, 30 cm (12 in) 10
Red, 60 cm (24 in) 15
Blue, 90 cm (36 in) 6
• Voltage Control
• Current Control
• AC Power Source
Important Notice: One Model 8968-7 must be ordered for each Four-Quadrant Dynamometer/Power Supply,
Model 8960, to unlock the SDK features.
With all multiple users licences, the software comes also all the
PDF for the above curriculum (not included in single-user
licences). With LVSIM-EMS, all the standard EMS laboratory
equipment is replaced by images of the actual EMS modules that students can manipulate on the computer
screen. Students can identify and set up equipment for a given exercise, make the necessary connections
between the virtual EMS modules, and verify the connections made without the need for actual EMS
equipment.
Sophisticated mathematical models fully simulate the electrical and mechanical characteristics of all the actual
EMS modules: power supplies, motors, generators, transformers, electrical and mechanical loads, etc. All
modules simulated in the LVSIM-EMS software feature the same front panel information as the actual EMS
modules. Short-circuit connections in the virtual equipment setup cause the virtual circuit-breaker protection to
trip. This trip condition is clearly indicated on the virtual EMS modules.
Used either as a complement to the actual EMS laboratory equipment, or as a stand-alone product, LVSIM-EMS
is a cost-effective tool that enables students to perform the same exercises as in the courseware of the above-
mentioned training systems. When used as a stand-alone package, the LVSIM-EMS software allows students to
perform hands-on activities related to electrical power and machines, including active, reactive, and apparent
power, phasors, ac/dc motors and generators, three-phase circuits, and transformers.
LVSIM-EMS is a web-browser based application available in three different configurations. The simulation
software can either be installed locally on a Windows® personal computer (local version), on a Windows server
(network version), or accessed directly online through the labvolt.com website at lvsim.labvolt.com (online
version). Both network and local versions are delivered with perpetual licence for the current version. The online
version is delivered as a annual licence with possibility to expand for more years.
Please visit https://lvsim.labvolt.com and try the online version!
Virtual Instrumentation
LVSIM-EMS comprises a set of conventional and specialized instruments that can be used for measuring,
observing, and analyzing electrical and mechanical parameters in electric power systems and power electronic
circuits. Each instrument appears as a window on the computer screen. The conventional instruments include
ac/dc voltmeters and ammeters, power meters, and an eight-channel oscilloscope. The specialized instruments
include a six-channel phasor analyzer, a harmonic analyzer, torque, speed, and mechanical power meters, and
user-programmable meters. The software is also provided with data-recording and graph-plotting capabilities.
The various instruments are briefly described in the next section of this datasheet.
Metering Window
The Metering window displays up to
eighteen meters, which can be
configured individually for measuring
ac/dc voltage and current, electrical
power (active, reactive, and apparent),
torque, speed, mechanical power, etc.
The voltage and current meters have
several modes of operation that allow
measurement of the mean (dc) value,
RMS value, crest factor, RMS value of a
particular harmonic (up to the 15th
value), RMS value of the harmonics, and total harmonic distortion (THD). Six of the eighteen meters are user-
programmable and give access to a larger variety of functions for measurement of power factor, efficiency,
impedance, frequency, energy, phase shift, etc. The layout of the meters in the Metering window is user-
customizable.
Oscilloscope
The Oscilloscope displays up to eight
waveforms simultaneously, each of a
different color for easy identification.
Each channel has independent vertical
controls similar to those found on
conventional oscilloscopes. An
automatic scale-setting function
allows the sensitivity of each channel
to be set automatically according to
the magnitude of the observed
parameter. The time base and trigger
controls are similar to those found on
most oscilloscopes. The RMS value,
average value, and frequency of each
observed parameters can be displayed
in the Oscilloscope window. Two vertical cursors can be activated to perform precise measurements at
particular points on the displayed waveforms. The Oscilloscope toolbar includes two memory buttons for saving
displayed waveforms.
Phasor Analyzer
The Phasor Analyzer displays the
phasors related to the measured
voltages and currents. The amplitude
and phase angle of each voltage and
current is clearly represented by the
orientation and length of their
corresponding phasors, allowing easy
comparison between the displayed
parameters. This produces a unique
and dynamic display of the voltages
and currents in a circuit (especially in
three-phase circuits) that cannot be
obtained with conventional
instruments. The RMS value, phase angle, and frequency of the voltage or current related to each phasor is
displayed in the Phasor Analyzer window.
Harmonic Analyzer
The Harmonic Analyzer allows
observation and analysis of the
harmonic components in the
measured voltages and currents. The
fundamental frequency can be
manually set to the ac power network
frequency or automatically set to the
frequency of the fundamental
component of the selected voltage or
current. The harmonic components of
the selected voltage or current can be
displayed using a vertical scale
graduated in either absolute or relative values. A group of data displays in the Harmonic Analyzer indicates the
values of the dc component of the selected voltage or current, as well as the total harmonic distortion (THD).
Vertical and horizontal cursors can be displayed to perform precise measurements at particular points on the
display. Since the equipment simulated by LVSIM-EMS produces only dc and sinusoidal ac signals (without
harmonics), the Harmonic Analyzer, which is intended for use with devices that produce harmonics, is not often
used with LVSIM-EMS.
Online Edition
The online version of LVSIM-EMS is accessible directly via the internet, and requires no software installation nor
any update since the latest version of the software is always available. The online version of LVSIM-EMS also
includes a demo mode that allows students to prepare laboratories in advance by familiarizing with the
equipment and connections. The demo mode does not require any login.
Computer Requirements
Local and Network Versions:
• One (1) USB 2.0 port for the security dongle, Microsoft Windows 10 operating system recommended
(compatible with Windows 7 and 8), basic dual core CPU, Google Chrome web browser installed (for
better experience)
Online Version:
• Microsoft Windows 10 operating system recommended (compatible with Windows 7 and 8 but not fully
compatible with mobile devices), basic dual core CPU, internet access (bandwidth usage of 50 KB/s
maximum), Google Chrome web browser installed (for better experience)
List of Manuals
Manual
Description
number
Electromechanical Training System (Manuals on CD-ROM) _________________________________ 579707 (86357A0)
AC Power Transmission Training System (Manuals on CD-ROM) _____________________________ 580209 (20521A0)
Electromechanical Systems Simulation Software (User Guide) ______________________________ 583879 (20858E0)
Manuals on CD-ROM – LVSIM-EMS (Workbook) __________________________________________ 584111 (30329A0)
Computer-Based Instruments for EMS (User Guide) ______________________________________ 584396 (36221E0)
Power Factor Correction (Workbook) ___________________________________________________590283 (20116-00)
Power Factor Correction (Workbook (Instructor)) _________________________________________ 590284 (2011610)
Power Factor Correction (Workbook (Instructor)) _________________________________________ 590285 (2011615)
Power Factor Correction (Workbook (Instructor)) _________________________________________ 590286 (201161A)
Power Factor Correction (Workbook (Instructor)) _________________________________________ 590287 (201161E)
AC Transmission Lines (Workbook) ____________________________________________________590297 (20521-00)
AC Transmission Lines (Workbook (Instructor)) __________________________________________ 590298 (2052110)
AC Transmission Lines (Workbook (Instructor)) __________________________________________ 590299 (2052115)
AC Transmission Lines (Workbook (Instructor)) __________________________________________ 590300 (205211A)
AC Transmission Lines (Workbook (Instructor)) __________________________________________ 590301 (205211E)
Electromechanical Systems Simulation Software (User Guide) ______________________________ 590337 (20858E0)
Software de simulación de sistemas electromecánicos (User Guide) _________________________ 590338 (20858E2)
Power Circuits and Transformers (Workbook) ____________________________________________590571 (30328-00)
(Workbook) _______________________________________________________________________ 590572 (3032801)
Circuitos de Potencia y Transformadores (Workbook) _____________________________________ 590573 (3032802)
Power Circuits and Transformers (Workbook (Instructor)) __________________________________ 590574 (3032810)
Sistema Electromecánico (EMS) de 0,2 kW / Guía del profesor (Workbook (Instructor)) _________ 590575 (3032812)
ElectroMechanical System ( EMS ) 0.2 kW (Workbook (Instructor)) __________________________ 590576 (3032815)
Circuitos de potencia y transformadores (Workbook (Instructor)) ___________________________ 590577 (3032817)
ElectroMechanical System ( EMS ) 0.2 kW (Workbook (Instructor)) __________________________ 590578 (303281A)
ElectroMechanical System (EMS) 0.2 kW (Workbook (Instructor)) ___________________________ 590579 (303281E)
Circuitos de potencia y transformadores (Workbook (Instructor)) ___________________________ 590580 (303281F)
AC/DC Motors and Generators (Workbook) _____________________________________________590581 (30329-00)
Machines c.a./c.c. (Workbook) ________________________________________________________ 590582 (3032901)
Motores y generadores cc/ca (Workbook) ______________________________________________ 590583 (3032902)
AC/DC Motors and Generators (Workbook (Instructor)) ____________________________________ 590584 (3032910)
Manual
Description
number
AC/DC Motors and Generators (Workbook (Instructor)) ____________________________________ 590585 (3032915)
AC/DC Motors and Generators (Workbook (Instructor)) ____________________________________ 590586 (303291A)
AC/DC Motors and Generators (Workbook (Instructor)) ____________________________________ 590587 (303291E)
Computer-Based Instruments for EMS (User Guide) ______________________________________ 590837 (36221E0)
Instruments informatisés (User Guide) _________________________________________________ 590838 (36221E1)
Instrumentos para EMS basados en computadora (User Guide) _____________________________ 590839 (36221E2)
Electric Power Technology Training Equipment (User Guide) ________________________________ 591259 (38486E0)
Equipos del Sistema didáctico en tecnología de la energía eléctrica (User Guide) ______________ 591260 (38486E2)
DC Power Circuits (Workbook) ________________________________________________________591809 (86350-00)
Circuitos cc (Workbook) _____________________________________________________________ 591810 (8635002)
Circuitos de Potência de CC (Workbook) ________________________________________________ 591811 (8635004)
DC Power Circuits (Workbook (Instructor)) ______________________________________________ 591812 (8635010)
Circuitos cc (Workbook (Instructor)) ___________________________________________________ 591813 (8635012)
Circuitos de Potência de CC (Workbook (Instructor)) ______________________________________ 591814 (8635014)
Permanent Magnet DC Machine (Workbook) ____________________________________________591842 (86357-00)
Máquina cc de imán permanente (Workbook) ___________________________________________ 591843 (8635702)
Máquina de CC de Imã Permanente (Workbook) _________________________________________ 591844 (8635704)
Permanent Magnet DC Machine (Workbook (Instructor)) ___________________________________ 591845 (8635710)
Máquina cc de imán permanente (Workbook (Instructor)) __________________________________ 591846 (8635712)
Máquina de CC de Imã Permanente (Workbook (Instructor)) ________________________________ 591847 (8635714)
Single-Phase AC Power Circuits (Workbook) _____________________________________________591848 (86358-00)
Circuitos ca monofásicos (Workbook) __________________________________________________ 591849 (8635802)
Single-Phase AC Power Circuits (Workbook (Instructor)) ___________________________________ 591850 (8635810)
Circuitos ca monofásicos (Workbook (Instructor)) ________________________________________ 591851 (8635812)
Three-Phase AC Power Circuits (Workbook) _____________________________________________591858 (86360-00)
Circuitos ca trifásicos (Workbook) _____________________________________________________ 591859 (8636002)
Circuitos de Potência de CA Trifásicos (Workbook) ________________________________________ 591860 (8636004)
Three-Phase AC Power Circuits (Workbook (Instructor)) ___________________________________ 591861 (8636010)
Circuitos ca trifásicos (Workbook (Instructor)) ___________________________________________ 591862 (8636012)
Circuitos de Potência de CA Trifásicos (Workbook (Instructor)) ______________________________ 591863 (8636014)
Three-Phase AC Power Circuits (Workbook (Instructor)) ___________________________________ 591864 (8636015)
Circuitos de Potência de CA Trifásicos (Workbook (Instructor)) ______________________________ 591865 (8636019)
Three-Phase AC Power Circuits (Workbook (Instructor)) ___________________________________ 591866 (863601A)
Three-Phase AC Power Circuits (Workbook (Instructor)) ___________________________________ 591867 (863601E)
Three-Phase Rotating Machines (Workbook) ____________________________________________591903 (86364-00)
Máquinas rotatorias trifásicas (Workbook) ______________________________________________ 591904 (8636402)
Three-Phase Rotating Machines (Workbook (Instructor)) __________________________________ 591905 (8636410)
Máquinas rotatorias trifásicas (Workbook (Instructor)) ____________________________________ 591906 (8636412)
Three-Phase Rotating Machines (Workbook (Instructor)) __________________________________ 591907 (8636415)
Máquinas rotatorias trifásicas (Workbook (Instructor)) ____________________________________ 591908 (8636417)
Three-Phase Rotating Machines (Workbook (Instructor)) __________________________________ 591909 (863641A)
Three-Phase Rotating Machines (Workbook (Instructor)) __________________________________ 591910 (863641E)
Máquinas rotatorias trifásicas (Workbook (Instructor)) ____________________________________ 591911 (863641F)
Single-Phase Power Transformers (Workbook) ___________________________________________591954 (86377-00)
Transformadores de potencia monofásicos (Workbook) ___________________________________ 591955 (8637702)
Single-Phase Power Transformers (Workbook (Instructor)) _________________________________ 591956 (8637710)
Manual
Description
number
Transformadores de potencia monofásicos (Workbook (Instructor)) _________________________ 591957 (8637712)
Three-Phase Transformer Banks (Workbook) ____________________________________________591967 (86379-00)
Bancos trifásicos de transformadores (Workbook) ________________________________________ 591968 (8637902)
Bancos de Transformadores Trifásicos (Workbook) _______________________________________ 591969 (8637904)
Three-Phase Transformer Banks (Workbook (Instructor)) __________________________________ 591970 (8637910)
Bancos trifásicos de transformadores (Workbook (Instructor)) ______________________________ 591971 (8637912)
Bancos de Transformadores Trifásicos (Workbook (Instructor)) _____________________________ 591972 (8637914)
Three-Phase Transformer Banks (Workbook (Instructor)) __________________________________ 591973 (8637915)
Bancos trifásicos de transformadores (Workbook (Instructor)) ______________________________ 591974 (8637917)
Bancos de Transformadores Trifásicos (Workbook (Instructor)) _____________________________ 591975 (8637919)
Three-Phase Transformer Banks (Workbook (Instructor)) __________________________________ 591976 (863791A)
Three-Phase Transformer Banks (Workbook (Instructor)) __________________________________ 591977 (863791E)
Bancos trifásicos de transformadores (Workbook (Instructor)) ______________________________ 591978 (863791F)
Computer-Based Instruments for EMS (User Guide) ______________________________________ 592016 (86718E0)
Instrumentation informatisée pour EMS (User Guide) _____________________________________ 592017 (86718E1)
Instrumentos para EMS computarizados (User Guide) ____________________________________ 592018 (86718E2)
Conventional DC Machines and Universal Motor (Workbook) _______________________________592168 (88943-00)
Máquinas cc convencionales y motor universal (Workbook) ________________________________ 592169 (8894302)
Conventional DC Machines and Universal Motor (Workbook (Instructor)) _____________________ 592170 (8894310)
Máquinas cc convencionales y motor universal (Workbook (Instructor)) ______________________ 592171 (8894312)
Conventional DC Machines and Universal Motor (Workbook (Instructor)) _____________________ 592172 (8894315)
Máquinas cc convencionales y motor universal (Workbook (Instructor)) ______________________ 592173 (8894317)
Conventional DC Machines and Universal Motor (Workbook (Instructor)) _____________________ 592174 (889431A)
Conventional DC Machines and Universal Motor (Workbook (Instructor)) _____________________ 592175 (889431E)
Máquinas cc convencionales y motor universal (Workbook (Instructor)) ______________________ 592176 (889431F)
Single-Phase Induction Motors (Workbook) ____________________________________________ 592177 (88944-00)
Motores de inducción monofásicos (Workbook) __________________________________________ 592178 (8894402)
Single-Phase Induction Motors (Workbook (Instructor)) ___________________________________ 592179 (8894410)
Motores de inducción monofásicos (Workbook (Instructor)) ________________________________ 592180 (8894412)
Single-Phase Induction Motors (Workbook (Instructor)) ___________________________________ 592181 (8894415)
Motores de inducción monofásicos (Workbook (Instructor)) ________________________________ 592182 (8894417)
Single-Phase Induction Motors (Workbook (Instructor)) ___________________________________ 592183 (889441A)
Single-Phase Induction Motors (Workbook (Instructor)) ___________________________________ 592184 (889441E)
Motores de inducción monofásicos (Workbook (Instructor)) ________________________________ 592185 (889441F)
DC Power Circuits (Workbook) ________________________________________________________ 594401 (863500C)
DC Power Circuits (Workbook (Instructor)) ______________________________________________ 594402 (863501C)
Single-Phase AC Power Circuits (Workbook) _____________________________________________ 594403 (863580C)
Single-Phase AC Power Circuits (Workbook (Instructor)) ___________________________________ 594404 (863581C)
Three-Phase AC Power Circuits (Workbook) _____________________________________________ 594405 (863600C)
Three-Phase AC Power Circuits (Workbook (Instructor)) ___________________________________ 594406 (863601C)
Circuitos ca trifásicos (Workbook (Instructor)) ___________________________________________ 594407 (863601F)
Circuitos ca trifásicos (Workbook (Instructor)) ___________________________________________ 594408 (8636017)
Máquinas Rotativas Trifásicas (Workbook) ______________________________________________ 594413 (8636404)
Máquinas Rotativas Trifásicas (Workbook (Instructor)) ____________________________________ 594414 (8636414)
Single-Phase Power Transformers (Workbook) ___________________________________________ 594445 (863770C)
Single-Phase Power Transformers (Workbook (Instructor)) _________________________________ 594446 (863771C)
Manual
Description
number
Three-Phase Transformer Banks (Workbook) ____________________________________________ 594447 (863790C)
Three-Phase Transformer Banks (Workbook (Instructor)) __________________________________ 594448 (863791C)
Corrección del factor de potencia (Workbook) ___________________________________________ 595688 (2011602)
Corrección del factor de potencia (Workbook (Instructor)) _________________________________ 595689 (201161F)
Corrección del factor de potencia (Workbook (Instructor)) _________________________________ 595690 (2011612)
Corrección del factor de potencia (Workbook (Instructor)) _________________________________ 595691 (2011617)
Dreiphasige Transformatorbanken (Workbook (Instructor)) ________________________________________ 8096770
Dreiphasige Transformatorbanken (Workbook) __________________________________________________ 8096772
Circuitos ca trifásicos (Workbook (Instructor)) ___________________________________________8099111 (863601J)
Circuitos ca trifásicos (Workbook) _____________________________________________________8099117 (863600J)
Three-Phase Rotating Machines (Workbook (Instructor)) _________________________________ 8099829 (863641C)
Three-Phase Rotating Machines (Workbook) ___________________________________________ 8099831 (863640C)
Circuits cc (Workbook (Instructor)) ___________________________________________________ 8106183 (8635011)
Circuits cc (Workbook) _____________________________________________________________ 8106185 (8635001)
Circuits cc (Workbook (Instructor)) ___________________________________________________ 8106187 (863501H)
Circuits cc (Workbook) _____________________________________________________________ 8106189 (863500H)
Circuits ca monophasés (Workbook (Instructor)) ________________________________________ 8107229 (8635811)
Circuits ca monophasés (Workbook) __________________________________________________ 8107234 (8635801)
Circuits ca monophasés (Workbook (Instructor)) ________________________________________ 8107236 (863581H)
Circuits ca monophasés (Workbook) __________________________________________________ 8107239 (863580H)
Circuits ca triphasés (Workbook (Instructor)) ___________________________________________ 8107837 (8636011)
Circuits ca triphasés (Workbook) _____________________________________________________ 8107839 (8636001)
Circuits ca triphasés (Workbook (Instructor)) ___________________________________________ 8107841 (863601H)
Circuits ca triphasés (Workbook) _____________________________________________________ 8107843 (863600H)
Circuits ca triphasés (Workbook (Instructor)) ___________________________________________ 8107845 (8636016)
Transformateurs de puissance monophasés (Workbook (Instructor)) _______________________ 8108882 (8637711)
Transformateurs de puissance monophasés (Workbook) _________________________________ 8108884 (8637701)
Transformateurs de puissance monophasés (Workbook (Instructor)) _______________________ 8108886 (863771H)
Transformateurs de puissance monophasés (Workbook) _________________________________ 8108888 (863770H)
Banque triphasées de transformateurs (Workbook (Instructor)) ____________________________ 8114282 (8637911)
Banque triphasées de transformateurs (Workbook) _____________________________________ 8114284 (8637901)
Banque triphasées de transformateurs (Workbook (Instructor)) ____________________________ 8114286 (8637916)
Banque triphasées de transformateurs (Workbook (Instructor)) ____________________________ 8114288 (863791H)
Banque triphasées de transformateurs (Workbook) _____________________________________ 8114290 (863790H)
Correction du facteur de puissance (Workbook (Instructor)) _______________________________ 8116570 (2011611)
Correction du facteur de puissance (Workbook) _________________________________________ 8116572 (2011601)
Correction du facteur de puissance (Workbook (Instructor)) _______________________________ 8116574 (2011616)
Machines tournantes triphasées (Workbook (Instructor)) _________________________________ 8116685 (8636411)
Machines tournantes triphasées (Workbook) ___________________________________________ 8116687 (8636401)
Machines tournantes triphasées (Workbook (Instructor)) _________________________________ 8116689 (8636416)
Líneas de transmisión ca (Workbook (Instructor)) _______________________________________ 8120197 (2052112)
Líneas de transmisión ca (Workbook) _________________________________________________ 8120199 (2052102)
Líneas de transmisión ca (Workbook (Instructor)) _______________________________________ 8120201 (2052117)
Líneas de transmisión ca (Workbook (Instructor)) _______________________________________ 8120202 (205211F)
Power Factor Correction (Workbook (Instructor)) ________________________________________ 8123643 (201161C)
Power Factor Correction (Workbook) __________________________________________________ 8123645 (201160C)
Manual
Description
number
Einphasiger Leistungstransformator (Workbook (Instructor)) ______________________________ 8136390 (863771G)
Einphasige Wechselstromkreise (Workbook) ___________________________________________ 8136392 (863770G)
Gleichstromkreise (Workbook (Instructor)) _____________________________________________ 8142232 (863501G)
Gleichstromkreise (Workbook) _______________________________________________________ 8142235 (863500G)
Einphasige Wechselstromkreise (Workbook (Instructor)) _________________________________ 8144177 (863581G)
Einphasige Wechselstromkreise (Workbook) ___________________________________________ 8144179 (863580G)
Dreiphasige Wechselstromkreise (Workbook (Instructor)) ________________________________ 8144181 (863601G)
Dreiphasige Wechselstromkreise (Workbook) __________________________________________ 8144183 (863600G)
Équipement didactique en technologie de l'énergie électrique (User Guide) __________________ 8153103 (38486E1)
Circuits ca monophasés (Workbook (Instructor)) ________________________________________ 8159185 (8635816)
Topic Coverage
• Replicates the Electromechanical Training System, enabling students to perform actual experiments
using virtual equipment
▪ Install, move, and remove EMS modules in and from the workstation
▪ Modify module connections at any time and change the color of wires
▪ Install a timing belt between two EMS machines
▪ Verify module connections using a tool that highlights all wires connected to a same circuit point
▪ Perform measurements of voltage, current, power, speed, torque, impedance, resistance, reactance,
and frequency and display the values on digital or analog meters
▪ Record measurements in a data table and plot graphs using the recorded data
▪ Display waveforms on a multi-channel oscilloscope and ac voltages and currents as phasors
• Students prepare for laboratories in advance using virtual equipment, thereby decreasing the time they
require to perform the exercises using actual equipment
• Decreases the quantity of actual equipment required per student
• Allows students to practice with EMS equipment operation and connection at home on a personal
computer