Talisay 20 Residential
Talisay 20 Residential
RECOMMENDING ISSUANCE:
AS TO :
AS TO :
AS TO :
AS TO :
12 AS TO :
.6
6
2 BU
ILD
IN
G
AR
EA TECHNICAL DESCRIPTIONS HEAD SECTION DATE
AS TO :
LINE BEARING DISTANCE
4 LOT 449-A-10-A
13 1-2 N 48deg 57' W 13.13 M
.1
3
2-3 N 46deg 02' E 6.21 M
3-4 S 48deg 26' E 12.66 M
07
0.70
Y
0.70
Y
6.07
6.07
5.25
4.75
3.05 2.20 0.82 RECOMMENDING ISSUANCE:
2.00 2.75 1.32
3.00
3.00
6.80
1.95
1.95
1.80
6.80
1.63
W4
ISSUED BY:
W1
D2 D3
5.05
5.25
5.40
5.20
3.00
3.00
3.10
3.30
3.40
3.40
0.10
W1 W1
0.10
D3
9.15
10.15
W2
11.57
11.42
D2
1.95
RIGHT SIDE ELEVATION
W4
SCALE : 1 : 100 MTS
X X D3
3.15
SCALE : 1 : 100 MTS
3.90
D3
3.75
W1
W1
0.70
0.70
6.22
6.17
3.15
1.65
D1
W1
3.00
2.42
3.00
W2 W2 W3
0.70
1.42
6.80
6.80
2.05 1.15 1.55 1.32 3.05 2.20 0.82
3.21 2.86 5.25
6.07 PANEL DOOR PVC DOOR
3.00
3.00
6.07
0.10
0.10
NO. OF SETS: 1 NO. OF SETS: 2
FINISHING: FINISHING:
TYPE: PANEL DOOR TYPE: PVC DOOR
GROUND FLOOR PLAN SECOND FLOOR PLAN
SCALE : 1 : 100 MTS SCALE : 1 : 100 MTS
0.70
3.00
3.00
6.80
6.80
PANEL DOOR SLIDING WINDOW
3.00
3.00 LOCATION: EXIT DOOR, BD1, BD2, MASTER'S BD LOCATION: LIVING, KITCHEN, FAMILY AREA, BD 1 & 2
0.10
0.10
CLEAR DOOR DIM.: 0.70 M x 2.10M CLEAR WINDOW. DIM.: 1.20 M x 1.20 M
NO. OF SETS: 4 NO. OF SETS: 6
FINISHING: FINISHING: ANALOK
TYPE: PANEL DOOR TYPE: SLIDING
L/4 L/4
WF-1
WF-1
WF-1
2.10
1.48
ISSUED BY:
WF-1 WF-1 WF-1
5.25
4.78
C1F1 C1F1 C1F1
HEAD BUILDING OFFICIAL DATE
WF-1
WF-1
3.30
6.07
3.15
L/5 L/5
GB 1-X GB 1-X
WF-1
1.25
C2F2 OPEN BELOW 0.20 0.20 0.20
C1F1 C1F1 C1F1
GB 1-X
13.13
12.66
GB 1-Y
GB 1-Y
GB 1-Y
GB 1-Y
3.35
WF-1
WF-1
3.80
3.90
2.10
0.30
0.30
0.30
GB 1-X GB 1-X
WF-1
7.88
7.88
8.20
8.20
OPEN BELOW
C1F1 C1F1 C1F1
GB 1-Y
GB 1-Y
GB 1-Y
GB 1-Y
LENGTH
3.75
3.75
4.08
3.98
L/4 L/4
GB 1-X GB 1-X
GB 1-Y
GB 1-Y
GB 1-Y
1.10
1.10
GB 1-X GB 1-X
3.10 2.97
6.07 3.05 2.10 0.92
6.07
5.25
3.05 2.20
L/5 L/5
6.05
0.20 0.20 0.20
2.00 4.05
0.30
0.30
0.30
1.95
RB 1 RB 1
1.80
RB 1
RB 1
RB 1
3.35
3.30
LENGTH
RB 1-Y
RB 1 RB 1
8.20
8.15
L/4 L/4
10.15
10.00
RB 1
RB 1
RB 1
3.75
3.75
8.20
8.20
RB 1-Y
RB 1-X RB 1 RB 1
RB 1
RB 1
RB 1
1.10
1.10
RB 1 RB 1
3.05 2.20
5.25
6.05
ROOF FRAMING PLAN
SCALE : 1 : 100 MTS L/5 L/5
ROOF PLAN
SCALE : 1 : 100 MTS 0.20 0.20 0.20
0.30
0.30
0.30
REPUBLIC OF THE PHILIPPINES
RECOMMENDING ISSUANCE:
1.81
MARK WxD (M) (M) (M) BAR HEAD SECTION DATE
ISSUED BY:
F1 1.00 X 1.00 0.25 1.00
3.00
F2 0.80 X 0.80 0.20 1.00
0.25
HEAD BUILDING OFFICIAL DATE
1.19
0.17
SCHEDULE OF BEAM REINFORCEMENT
BEAM DIMENSION LEFT SUPPORT MIDSPAN RIGHT SUPPORT
MARK WxD (M) TOP BARS BOT. BARS TOP BARS BOT. BARS TOP BARS BOT. BARS
0.45
GB 1-X 0.20 X 0.30
0.60
GB 1-Y 0.20 X 0.30
RB 1 0.20 X 0.30
0.15
0.60
0.60
C1 0.20 X 0.30 SECOND FLR. TO ROOF DECK
C2 0.20 X 0.30 FOOTING TO SECOND FLR.
0.20
LONG SPAN
0.50
L/4 L/4
S/4
SHORT SPAN
0.80
0.75
1.00
1.00
0.20
0.25
S/4
1.00 0.80
0.20 0.20
L/4
0.10
0.80
0.30
0.30
1.00
SCHEDULE OF LOADS: REPUBLIC OF THE PHILIPPINES
6.07
6.07
CKT. NO. DESCRIPTION VOLTS PHASE POWER A CB CONDUCTOR CONDUIT 4.75
5.25
3.05 2.20 0.82
2.00 2.75 1.32
1 6 LIGHTING OUTLET 220 90 0.41 20AT2P RECOMMENDING ISSUANCE:
1.95
1.95
1.80
1.63
HEAD SECTION DATE
4 1 AIR CONDITION OUTLET 1119 5.09 30AT2P
ISSUED BY:
5 1 AIR CONDITION OUTLET 1119 5.09 30AT2P
5.05
5.25
5.20
5.03
6 1 AIR CONDITION OUTLET 1119 5.09 30AT2P C1
3.10
3.30
3.40
3.40
7 4 CONVENIENCE OUTLET 1440 6.54 30AT2P HEAD BUILDING OFFICIAL DATE
9.15
8 SPARE 30AT2P
10.15
TOTAL 29.17
11.42
11.20
1.95
3.15
MAIN WIRE DESIGN: MAIN CB DESIGN:
3.90
3.80
Ic = (( 0.25 x 6.54) + 29.17) 0.80 Ic = ( (2.00 x 6.54) + 29.17 ) 0.80
C
3
= 24.64 Amps. = 33.80 Amps.
6.22
6.17
3.15
use : 60AT2P, bolt - on type MCCB
1.65
2.37
TO POWER SOURCE
M
1.42
LEGEND:
2.05 1.15 2.87 3.05 2.20 0.82
15 WATTS PIN LIGHT 3.21 2.86 5.25
6.07 6.07
A.C.O
AIRCONDITION OUTLET 60AT2P
REF
REFRIGERATOR
1 20AT2P 30AT2P
2 6.07
6.07
5.25
4.75
S1 SINGLE SWITCH 3.05 2.20 0.82
3 20AT2P 30AT2P
4 2.00 2.75 1.32
5 6
1.95
1.95
1.80
1.63
S3 THREE GANG SWITCH 30AT2P 30AT2P
5.05
C.O
7 5.25
5.20
SPARE
S3W
5.03
THREE-WAY SWITCH 30AT2P 30AT2P
3.10
3.30
3.40
3.40
C5
PB
PANEL BOARD
9.15
10.15
C.O
A.C.O
C.O
C.O
M KILO-WATT HOUR METER
11.42
11.20
1.95
C2
A.C.O
C.O
3.15
CIRCUIT HOMERUN
C.O
3.90
3.80
C6
SINGLE LINE DIAGRAM C4 C7
C.O
6.22
6.17
3.15
GENERAL NOTES AND SPECIFICATIONS:
1.65
A.C.O
C.O
2.37
1.42
1. ALL ELECTRICAL WORKS AND INSTALLATIONS HEREIN SHALL CONFORM WITH THE LATEST APPROVED
EDITION OF THE PHILIPPINE ELECTRICAL CODE RULES AND REGULATIONS OF THE LOCAL AND NATIONAL
AUTHORITIES CONCERNED IN ENFORCEMENT OF ELECTRICAL LAWS AND ORDINANCES.
2.05 1.15 2.87 3.05 2.20 0.82
2. ALL MATERIALS TO BE USED SHALL BE NEW AND APPROVED TYPE FOR BOTH PURPOSE AND LOCATION INTENDED.
LOCATION PLAN
3.21 2.86 5.25
6.07 6.07
3. NO BRANCH CIRCUIT SHALL HAVE A LOAD OF MORE THAN 80% OF ITS RATING.
NOT TO SCALE
4. NO BRANCH CIRCUIT CONDUCTORS SHALL BE USED SMALLER THAN 3.5 mm. sq.
GROUND FLOOR SECOND FLOOR THIS SITE
POWER LAY-OUT PLAN POWER LAY-OUT PLAN
SCALE : 1 : 100 MTS SCALE : 1 : 100 MTS
6. ADEQUATE AND EFFECTIVE GROUNDING SHALL BE PROVIDED TO ALL METTALIC CONDUITS,CABINETS AND EQUIPTMENTS.
7. NO REVISION IN THE DESIGN SHALL BE DONE WITHOUT PRIOR KNOWLEDGE AND APPROVAL OF THE DESIGNER,
8. ANY SUCH REVISION DONE WITHOUT APPROVAL SHALL CAUSE RESPONSIBILITY OF THE DESIGNER TO CEASE AS A WHOLE.
6.07
5.25 6.07 REPUBLIC OF THE PHILIPPINES
1.95
1.63
1.95
1.80
1.95 HEAD SECTION DATE
5.25
1.80
5.40
5.05
5.20
ISSUED BY:
3.30
3.40
3.10
3.40
5.05
5.20
9.15
3.10
3.40
10.15
11.57
11.42
1.95
10.15
3.15
3.90
3.80
11.42
1.95
6.17
3.15
6.22
3.15
LOCATION PLAN
1.65
6.22
3.15
NOT TO SCALE
2.37
1.65
1.42
1.42
SECOND FLOOR DRAINAGE LAY-OUT PLAN GROUND FLOOR WATER LINE LAY-OUT PLAN
SCALE: 1:100 METERS
SCALE: 1:100 METERS
1.90
6.07
1.63
0.80
1.00
5.25
5.40
3.30
3.40
THIS SITE
9.15
1.90 11.57
1.15 0.65
3.90
0.50 0.50
3.80
0.60
0.10
6.17
0.30
0.60
2.37
0.40
1.40
3.21 2.87
6.07 0.40
0.10
GROUND FLOOR DRAINAGE LAY-OUT PLAN
SCALE: 1:100 METERS
0.50
0.10
DRAINAGE LINE
0.10