0% found this document useful (0 votes)
36 views6 pages

Talisay 20 Residential

The document outlines a site development plan for a construction project in the Philippines, including technical descriptions, location plans, and various architectural details such as floor plans and elevation views. It provides specifications for materials and dimensions for structural elements like footings, beams, and columns. Additionally, it includes a schedule of electrical loads and recommendations for issuance by relevant authorities.

Uploaded by

tabsamsee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views6 pages

Talisay 20 Residential

The document outlines a site development plan for a construction project in the Philippines, including technical descriptions, location plans, and various architectural details such as floor plans and elevation views. It provides specifications for materials and dimensions for structural elements like footings, beams, and columns. Additionally, it includes a schedule of electrical loads and recommendations for issuance by relevant authorities.

Uploaded by

tabsamsee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

REPUBLIC OF THE PHILIPPINES

RECOMMENDING ISSUANCE:

HEAD SECTION DATE


ISSUED BY:

HEAD BUILDING OFFICIAL DATE

AS TO :

HEAD SECTION DATE

AS TO :

HEAD SECTION DATE

AS TO :

HEAD SECTION DATE

AS TO :

PERSPECTIVE LOCATION PLAN


NOT TO SCALE
NOT TO SCALE
3
1
THIS SITE
6.2

HEAD SECTION DATE

12 AS TO :
.6
6

2 BU
ILD
IN
G
AR
EA TECHNICAL DESCRIPTIONS HEAD SECTION DATE

AS TO :
LINE BEARING DISTANCE
4 LOT 449-A-10-A
13 1-2 N 48deg 57' W 13.13 M
.1
3
2-3 N 46deg 02' E 6.21 M
3-4 S 48deg 26' E 12.66 M
07

HEAD SECTION DATE


6.

4-1 S 41deg 44' W 6.07 M AS TO :

TIE LINE: S 88 deg 34' W, 64.18 M FROM BBM


1 NO. 7 , TALISAY-MINGLANILLA ESTATE

SITE DEVELOPMENT PLAN


SCALE : 1 : 100M HEAD SECTION DATE
REPUBLIC OF THE PHILIPPINES

0.70
Y

0.70
Y
6.07
6.07
5.25
4.75
3.05 2.20 0.82 RECOMMENDING ISSUANCE:
2.00 2.75 1.32

3.00
3.00

6.80
1.95
1.95

HEAD SECTION DATE

1.80

6.80
1.63
W4

ISSUED BY:
W1
D2 D3

5.05
5.25

5.40

5.20

3.00
3.00
3.10
3.30

HEAD BUILDING OFFICIAL DATE

3.40
3.40

0.10
W1 W1

0.10
D3
9.15

10.15
W2

LEFT SIDE ELEVATION

11.57

11.42
D2

1.95
RIGHT SIDE ELEVATION
W4
SCALE : 1 : 100 MTS
X X D3

3.15
SCALE : 1 : 100 MTS
3.90

D3

3.75
W1
W1

0.70

0.70
6.22
6.17

3.15

1.65
D1
W1

3.00
2.42

3.00
W2 W2 W3

0.70
1.42

6.80

6.80
2.05 1.15 1.55 1.32 3.05 2.20 0.82
3.21 2.86 5.25
6.07 PANEL DOOR PVC DOOR

3.00

3.00
6.07

LOCATION: ENTRANCE DOOR LOCATION: T&B


CLEAR DOOR DIM.: 0.90 M x 2.10M CLEAR DOOR DIM.: 0.60 M x 2.10M

0.10

0.10
NO. OF SETS: 1 NO. OF SETS: 2
FINISHING: FINISHING:
TYPE: PANEL DOOR TYPE: PVC DOOR
GROUND FLOOR PLAN SECOND FLOOR PLAN
SCALE : 1 : 100 MTS SCALE : 1 : 100 MTS

REAR ELEVATION FRONT ELEVATION


SCALE : 1 : 100 MTS SCALE : 1 : 100 MTS
0.70

0.70
3.00

3.00
6.80

6.80
PANEL DOOR SLIDING WINDOW
3.00

3.00 LOCATION: EXIT DOOR, BD1, BD2, MASTER'S BD LOCATION: LIVING, KITCHEN, FAMILY AREA, BD 1 & 2
0.10
0.10

CLEAR DOOR DIM.: 0.70 M x 2.10M CLEAR WINDOW. DIM.: 1.20 M x 1.20 M
NO. OF SETS: 4 NO. OF SETS: 6
FINISHING: FINISHING: ANALOK
TYPE: PANEL DOOR TYPE: SLIDING

LONGITUDINAL SECTION THRU Y-Y CROSS SECTION THRU Y-Y


SCALE : 1:100 MTS
SCALE : 1 : 100 MTS

SCHEDULE OF DOORS AND WINDOWS


SCALE : 1 : 40MTS

SLIDING WINDOW SLIDING WINDOW SLIDING WINDOW


LOCATION: MASTER'S & DINNING LOCATION: MASTER'S BD LOCATION: T&B
CLEAR WINDOW. DIM.: 0.70 M x 1.20 M CLEAR WINDOW. DIM.: 1.80 M x 1.20 M CLEAR WINDOW. DIM.: 0.60 M x 0.60 M
NO. OF SETS: 3 NO. OF SETS: 1 NO. OF SETS: 2
FINISHING: ANALOK FINISHING: ANALOK FINISHING: ANALOK
TYPE: SLIDING TYPE: SLIDING TYPE: SLIDING
LENGTH

REPUBLIC OF THE PHILIPPINES

L/4 L/4

6.07 RECOMMENDING ISSUANCE:


2.05 2.60 1.42

WF-1

HEAD SECTION DATE

WF-1
WF-1
2.10

1.48
ISSUED BY:
WF-1 WF-1 WF-1
5.25

4.78
C1F1 C1F1 C1F1
HEAD BUILDING OFFICIAL DATE
WF-1

WF-1

3.30
6.07
3.15

3.05 1.40 0.70 0.92

L/5 L/5
GB 1-X GB 1-X
WF-1

1.25
C2F2 OPEN BELOW 0.20 0.20 0.20
C1F1 C1F1 C1F1
GB 1-X
13.13

12.66

GB 1-Y

GB 1-Y

GB 1-Y

GB 1-Y

3.35
WF-1

WF-1

3.80
3.90

2.10

0.30

0.30

0.30
GB 1-X GB 1-X
WF-1
7.88

7.88

8.20

8.20
OPEN BELOW
C1F1 C1F1 C1F1

GB 1-Y

GB 1-Y

GB 1-Y

GB 1-Y
LENGTH
3.75

3.75
4.08
3.98

L/4 L/4
GB 1-X GB 1-X
GB 1-Y

GB 1-Y

GB 1-Y
1.10

1.10
GB 1-X GB 1-X
3.10 2.97
6.07 3.05 2.10 0.92
6.07

FOUNDATION PLAN SECOND FLOOR FRAMING PLAN


SCALE : 1 : 100 MTS SCALE : 1 : 100 MTS

5.25
3.05 2.20
L/5 L/5

6.05
0.20 0.20 0.20
2.00 4.05

0.30

0.30

0.30
1.95

RB 1 RB 1
1.80

RB 1

RB 1

RB 1

3.35
3.30

LENGTH
RB 1-Y

RB 1 RB 1
8.20
8.15

L/4 L/4
10.15

10.00

RB 1

RB 1

RB 1
3.75

3.75
8.20

8.20
RB 1-Y

RB 1-X RB 1 RB 1
RB 1
RB 1
RB 1
1.10

1.10

RB 1 RB 1

3.05 2.20
5.25

6.05
ROOF FRAMING PLAN
SCALE : 1 : 100 MTS L/5 L/5
ROOF PLAN
SCALE : 1 : 100 MTS 0.20 0.20 0.20
0.30

0.30

0.30
REPUBLIC OF THE PHILIPPINES

RECOMMENDING ISSUANCE:

SCHEDULE OF FOOTING REINFORCEMENT


FOOTING DIMENSION THICKNESS DEPTH MAIN REINFORCING

1.81
MARK WxD (M) (M) (M) BAR HEAD SECTION DATE
ISSUED BY:
F1 1.00 X 1.00 0.25 1.00

3.00
F2 0.80 X 0.80 0.20 1.00
0.25
HEAD BUILDING OFFICIAL DATE

1.19

0.17
SCHEDULE OF BEAM REINFORCEMENT
BEAM DIMENSION LEFT SUPPORT MIDSPAN RIGHT SUPPORT
MARK WxD (M) TOP BARS BOT. BARS TOP BARS BOT. BARS TOP BARS BOT. BARS

0.45
GB 1-X 0.20 X 0.30

0.60
GB 1-Y 0.20 X 0.30
RB 1 0.20 X 0.30

0.15
0.60

SCHEDULE OF COLUMN REINFORCEMENT


COLUMN DIMENSION NUMBER REMARKS
MARK WxD (M) BAR (M)
C1 0.20 X 0.30 FOOTING TO SECOND FLR.

0.60
C1 0.20 X 0.30 SECOND FLR. TO ROOF DECK
C2 0.20 X 0.30 FOOTING TO SECOND FLR.

0.20
LONG SPAN
0.50

L/4 L/4
S/4

SHORT SPAN

0.80
0.75

1.00
1.00

0.20
0.25
S/4

1.00 0.80
0.20 0.20

L/4
0.10

0.80

0.30
0.30
1.00
SCHEDULE OF LOADS: REPUBLIC OF THE PHILIPPINES
6.07
6.07
CKT. NO. DESCRIPTION VOLTS PHASE POWER A CB CONDUCTOR CONDUIT 4.75
5.25
3.05 2.20 0.82
2.00 2.75 1.32
1 6 LIGHTING OUTLET 220 90 0.41 20AT2P RECOMMENDING ISSUANCE:

2 4 CONVENIENCE OUTLET 1440 6.54 30AT2P


3 6 LIGHTING OUTLET 90 0.41 20AT2P

1.95
1.95

1.80
1.63
HEAD SECTION DATE
4 1 AIR CONDITION OUTLET 1119 5.09 30AT2P
ISSUED BY:
5 1 AIR CONDITION OUTLET 1119 5.09 30AT2P

5.05
5.25

5.20
5.03
6 1 AIR CONDITION OUTLET 1119 5.09 30AT2P C1

3.10
3.30

3.40
3.40
7 4 CONVENIENCE OUTLET 1440 6.54 30AT2P HEAD BUILDING OFFICIAL DATE

9.15
8 SPARE 30AT2P

10.15
TOTAL 29.17

11.42
11.20

1.95

3.15
MAIN WIRE DESIGN: MAIN CB DESIGN:

3.90

3.80
Ic = (( 0.25 x 6.54) + 29.17) 0.80 Ic = ( (2.00 x 6.54) + 29.17 ) 0.80

C
3
= 24.64 Amps. = 33.80 Amps.

6.22
6.17

3.15
use : 60AT2P, bolt - on type MCCB

1.65
2.37
TO POWER SOURCE
M

1.42
LEGEND:
2.05 1.15 2.87 3.05 2.20 0.82
15 WATTS PIN LIGHT 3.21 2.86 5.25
6.07 6.07

15 WATTS LED LIGHT


GROUND FLOOR SECOND FLOOR
LIGHTING LAY-OUT PLAN LIGHTING LAY-OUT PLAN
C.O
CONVENIENCE OUTLET SCALE : 1 : 100 MTS SCALE : 1 : 100 MTS

A.C.O
AIRCONDITION OUTLET 60AT2P

REF
REFRIGERATOR
1 20AT2P 30AT2P
2 6.07
6.07
5.25
4.75
S1 SINGLE SWITCH 3.05 2.20 0.82

3 20AT2P 30AT2P
4 2.00 2.75 1.32

S2 TWO GANG SWITCH

5 6

1.95
1.95

1.80
1.63
S3 THREE GANG SWITCH 30AT2P 30AT2P

5.05
C.O
7 5.25

5.20
SPARE
S3W

5.03
THREE-WAY SWITCH 30AT2P 30AT2P

3.10
3.30

3.40
3.40
C5
PB
PANEL BOARD
9.15

10.15

C.O
A.C.O

C.O
C.O
M KILO-WATT HOUR METER

11.42
11.20

1.95
C2

A.C.O

C.O

3.15
CIRCUIT HOMERUN
C.O
3.90

3.80

C6
SINGLE LINE DIAGRAM C4 C7

C.O

6.22
6.17

3.15
GENERAL NOTES AND SPECIFICATIONS:

1.65
A.C.O

C.O
2.37

1.42
1. ALL ELECTRICAL WORKS AND INSTALLATIONS HEREIN SHALL CONFORM WITH THE LATEST APPROVED
EDITION OF THE PHILIPPINE ELECTRICAL CODE RULES AND REGULATIONS OF THE LOCAL AND NATIONAL
AUTHORITIES CONCERNED IN ENFORCEMENT OF ELECTRICAL LAWS AND ORDINANCES.
2.05 1.15 2.87 3.05 2.20 0.82
2. ALL MATERIALS TO BE USED SHALL BE NEW AND APPROVED TYPE FOR BOTH PURPOSE AND LOCATION INTENDED.

LOCATION PLAN
3.21 2.86 5.25
6.07 6.07
3. NO BRANCH CIRCUIT SHALL HAVE A LOAD OF MORE THAN 80% OF ITS RATING.
NOT TO SCALE
4. NO BRANCH CIRCUIT CONDUCTORS SHALL BE USED SMALLER THAN 3.5 mm. sq.
GROUND FLOOR SECOND FLOOR THIS SITE
POWER LAY-OUT PLAN POWER LAY-OUT PLAN
SCALE : 1 : 100 MTS SCALE : 1 : 100 MTS
6. ADEQUATE AND EFFECTIVE GROUNDING SHALL BE PROVIDED TO ALL METTALIC CONDUITS,CABINETS AND EQUIPTMENTS.

7. NO REVISION IN THE DESIGN SHALL BE DONE WITHOUT PRIOR KNOWLEDGE AND APPROVAL OF THE DESIGNER,

8. ANY SUCH REVISION DONE WITHOUT APPROVAL SHALL CAUSE RESPONSIBILITY OF THE DESIGNER TO CEASE AS A WHOLE.
6.07
5.25 6.07 REPUBLIC OF THE PHILIPPINES

3.05 2.20 0.82 2.00 2.75 1.32


6.07
5.25
3.05 2.20 0.82 RECOMMENDING ISSUANCE:

1.95

1.63
1.95

1.80
1.95 HEAD SECTION DATE

5.25
1.80

5.40
5.05

5.20
ISSUED BY:

3.30

3.40
3.10

3.40
5.05

5.20

9.15
3.10

HEAD BUILDING OFFICIAL DATE

3.40

10.15

11.57
11.42
1.95
10.15

REGISTERED MASTER PLUMBER

3.15

3.90

3.80
11.42
1.95

6.17
3.15

6.22
3.15
LOCATION PLAN

1.65
6.22
3.15

NOT TO SCALE

2.37
1.65

1.42
1.42

3.05 2.20 0.82


6.07

3.05 2.20 0.82


6.07
SECOND FLOOR WATER LINE LAY-OUT PLAN 3.21 2.87
SCALE: 1:100 METERS 6.07

SECOND FLOOR DRAINAGE LAY-OUT PLAN GROUND FLOOR WATER LINE LAY-OUT PLAN
SCALE: 1:100 METERS
SCALE: 1:100 METERS

1.90
6.07

1.05 0.55 4.75


2.00 2.75 1.32
1.95

1.63
0.80
1.00

5.25

5.40
3.30

3.40
THIS SITE
9.15

1.90 11.57

1.15 0.65
3.90

0.50 0.50
3.80

0.60
0.10

6.17
0.30

0.60
2.37
0.40
1.40

ISOMETRIC PLUMBING LAYOUT


WATER LINE 0.50

3.21 2.87
6.07 0.40

0.10
GROUND FLOOR DRAINAGE LAY-OUT PLAN
SCALE: 1:100 METERS

ISOMETRIC PLUMBING LAYOUT

0.50

0.10
DRAINAGE LINE

0.10

You might also like