Catalog Series 551 553 Alu 1 4 1 2 3 2 80087 Asco en 6316780
Catalog Series 551 553 Alu 1 4 1 2 3 2 80087 Asco en 6316780
Features
12 2 12 2 10
• The monostable spool valves in conformity with IEC 61508 Standard (2010 route 2H
3 1 3 1
2
2
version) have TÜV (551 series) and EXIDA (551-553 series) certified with integrity
levels: SIL 2 for HFT = 0 / SIL 3 for HFT = 1 12 3 1
12 3 1 10
General
Differential pressure 2 - 10.4 bar [1 bar =100 kPa]
Flow (Qv at 6 bar) 1/4” = 860 l/min (ANR)
1/2” = 3800 l/min
Fluids () Temperature range (TS) Seal materials ()
air, inert gas, filtered -25°C to +60°C NBR (nitrile) + PUR (polyurethane)
1/4” 6 0.75 12.5 2 10 - 551A106 POWER LEVELS - cold electrical holding values (watt)
1/2” 13 3.15 52.5 2 10 - 553A106
(1)
Certified IEC 61508 Functional Safety data, use suffix "SL".
(2)
UL CSA
STEP 3
Suffix table Select suffix (combination) if required.
Suffix Power level Refer to the suffix table, respect the
Description
1 2 3 4 5 LP RP MP BP indicated power level.
G D Non-electrical, 2 GD, construction safety, gas/dust
- - - - GD suffix available for air operated
(EN ISO 80079-36/37) version only (do not use manual
M S Screw type manual operator - l - l operator suffix).
S L Certified IEC 61508 Functional Safety data (1) - l - l Example: MS
STEP 4
Select voltage. Refer to standard
voltages on page: 3
Example: 230V / 50Hz
STEP 5
Final catalogue / ordering number
Example:
SCG551A005MS 230 V / 50 Hz
Electrical characteristics
Coil insulation class F
Electrical safety IEC 335
Standard voltages DC (=) 24V - 48V
AC (~) 24V - 48V - 115V - 230V/50Hz; other voltages and 60Hz are available on request
Power ratings Operator Electrical
ambient Replacement coil
Prefix Inrush Holding Hot/Cold temperature enclosure Type
Safety code
option = range (TS) protection = (1)
~ ~ ~
(VA) (VA) (W) (W) (C°) (EN 60529) 230 V/50 Hz 24V/DC
Basic power (BP)
SC 15 7 5 4/5 -25 to +60 EN 60730 IP65, moulded 400727-117 400727-185 02
PV - - 6.3 - -40 to +65 II2G Ex mb IIC T3 Gb,II2D Ex mb IIIC Db IP67 moulded - (2) - (2) 04
PV - - - 6.9 -40 to +40 II2G Ex mb IIC T3 Gb,II2D Ex mb IIIC Db IP67 moulded - (2) - (2) 04
EF 55 23 10.5 9/11.2 -40 to +52/40 NEMA type 7 and 9 NEMA 4X - - 07-08
EFHT 55 23 10.5 9/11.2 -40 to +52/40 NEMA type 7 and 9 NEMA 4X - - 07-08
JBEF 55 23 10.5 9/11.2 -40 to +52/40 NEMA type 7 and 9 NEMA 4X - - 09-10
JBEFHT 55 23 10.5 9/11.2 -40 to +52/40 NEMA type 7 and 9 NEMA 4X - - 09-10
Reduced power (RP)
SC 6 3.5 2.5 2.5/3 -25 to +60 EN 60730 IP65, moulded 400127-097 400904-542 01
PV - - 4 - -40 to +60/65 II2G Ex mb IIC T4-T3 Gb,II2D Ex mb IIIC Db IP67 moulded - (2) - (2) 03
PV - - - 3 -40 to +40/60/60 II2G Ex mb IIC T5-T4-T3 Gb,II2D Ex mb IIIC Db IP67 moulded - (2) - (2) 03
WBLP - - 3.5 -/4 -40 to +65 II2G Ex e mb IIC T4 Gb, II2D Ex tb IIIC Db IP67 PBT - (2) - (2) 05-06
(1)
Refer to the dimensional drawings on pages: 4 to 5 (Air operated versions: Refer to the dimensional drawings on pages: 7).
(2)
Multiple coil kits are available under ATEX/IECEx, contact us
Electrical connections
Prefix Connection
SC Type 01: Spade plug connector with cable gland DIN 43650, 11 mm, industry standard B, for cables with an outer diameter from 6 to
8 mm
Type 02: Spade plug connector with cable gland EN175301-803A (ISO 4400) for cables with an outer diameter from 6 to 10 mm
PV Moulded-in cable, standard length 2 m
WBLP M20 cable gland for cables with an outer diameter from 7 to 8,5 mm
EF 1/2" NPT conduits
JBEF EF + Junction box
Additional options
• Other pipe threads are available on request
• Ex mb (prefix "PV") solenoid can be supplied with various cable lengths
Installation
• Multi language installation/maintenance instructions are included with each valve
• The valves can be mounted in any position without affecting operation
• Do not connect the pressure supply to the exhaust port 3. The “environmentally-protected” construction is not
adapted for a “distributing” function or use in NO function. Contact us for functions available in specific versions
• IEC 61508 Functional Safety (suffix SL). Check temperature range of valve body and solenoid for suitability. For prob-
ability of failure, contact us
• It is necessary to connect pipes or fittings to the exhaust ports to protect the internal parts of the spool valve and
its pneumatic operator if used outside or in harsh environments (dusts, liquids etc.)
• Threaded pipe connection identifier is 8 = NPT (ANSI 1.20.3); G = G (ISO 228/1)
80049GB-2022/R01
=
= =
D
D
3 2 1 3 2 1
=
3 x 1/4”
F E F E 3 x 1/2”
N
2 90°
N
180° 1
0
G
=
O
O
=
=
2
=
360°
M
360°
M
L
L
3 1
=
=
=
M5
=
M5
P Q 1 0
3 1
1 P Q
I
I
J J
H K H
H K H
=
D
= =
= =
D1
D
3 2 1
=
3 2 1
3 x 1/4" 3 x 1/2”
F E
F E
2
N
1 2
N
=
G
=
=
2
O
=
360°
M
M
O
L
L
3 1
=
=
=
=
M5
PQ 1
3 1
0
I 1 P Q
I
J J
K
K
551A017/A017MS/A018/A018MS/A067/A067MS/A068/A068MS 553A017/A017MS/A018/A018MS/A067/A067MS/A068/A068MS
=
=
D1
D
=
= =
D1
=
D
3 2 1
=
3 2 1
=
3 x 1/4"
F E 3 x 1/2”
F E
N
2
2
N
1
G
0
O
O
=
=
=
2
360°
=
M
L
360°
80049GB-2022/R01
M
L
3 1
=
=
=
P Q 1 0
3 1
1 P Q
I I
J J
K K
=
=
D1
D
D1
= =
= =
=
D
3 2 1
=
3 2 1
3 x 1/4"
F E F E 3 x 1/2"
2
1
2
0
=
G
G
=
=
2
=
360°
M
360°
L
M
L
3 1
=
=
=
=
P Q 1
3 1
0
I 1 P Q
I
J J
K K
=
=
=
= =
D1
D1
D
D
3 2 1
=
3 2 1
=
=
3 x 1/4"
H F E H F E 3 x 1/2"
G
G
2
2
O
1
0
=
=
=
2
=
360°
360°
M
M
L
L
3 1
=
=
=
=
P Q 1
3 1
0
I 1 P Q
J I
K J
K
1 2 mounting holes: 5.3 mm dia.; Spotfacing: 9 mm dia., depth 5 mm
2 2 mounting holes: 6.5 mm dia.; Spotfacing: 11 mm dia., depth 6 mm
Connectable pilot exhaust port
Prefix/ Power
(1)
Weight
Type D D1 E F G H H1 I J K L M N O P Q
option level Monostable Bistable
01 (551) SC RP 27.5 - 33 83.5 52 13 - 93.5 145 198 32 45 27 72 9.5 12 0.35 0.43
02 (553) SC BP 40.2 - 16 114.2 59.2 21.8 - 111.6170.2233.3 51 72.3 20 92.3 12.1 19.5 0.69 0.99
03 (551) PV RP 27.5 29 33 83.5 36.5 13 - 93.5 145 198 32 45 13 58 9.5 12 0.37 0.49
04 (553) PV BP 40.2 - 16 114.2 36.5 21.8 - 110.6170.2233.3 51 72.3 0.3 92.3 12.1 19.5 0.72 1.02
05 (551) WBLP RP 27.5 37 33 83.5 81.5 - - 93.5 145 198 32 45 59 104 9.5 12 0.44 0.63
06 (553) WBLP RP 40.2 37 16 114.2 81.5 - - 110.6170.2233.3 51 72.3 45.35117.65 12.1 19.5 0.79 1.16
07 (551) EF BP 27.5 30.5 33 83.5 53 - - 93.5 145 198 32 45 - - 9.5 12 0.45 0.63
80049GB-2022/R01
6 88100919 - 65
7 88100920 -
10
8 88100921 -
9 88100922 - 1/4 (551 Series)
10 88100923 -
11 88100924 -
12 88100925 -
(551)
12
19 (551)
194 (551)
27 (553)
181 (551)
238 (553)
184
260 (553)
3 3 3 3
148 (551)
2 2 2 2
202 (553)
1 1 1 1
92 (551)
551
127.5 (553)
87 (551)
75 (551)
134 (553)
23 (551)
108 (553)
65
32 (553)
E
35 (551) 60
C 4Ø 6.5 (551)
B 52 (553)
4Ø 9 (553)
50 (551)
A (551 Series)
82 (551) 75 (553) 30 (551)
113.3 (553) 23 (553)
This mounting arrangement allows valves to be mounted in the positions bellow.
Not possible with supply rail Only with supply rail
and isolation valves with isolation valves
(551-553) (551)
2 (551-553) (551-553)
(551-553) (551-553) (551 Series) 2
(551) (551)
80049GB-2022/R01
216.3 (553)
2 2
159 (551)
(551)
196.3 (553)
132 (551)
=
=
D
D
=
3 2 1
3 2 1
=
3 x 1/4"
F E
F E 3 x 1/2"
G1/8" 2
2
G1/4"
=
2
=
=
M
L
=
12 3 1 10
=
M
L
=
1
=
P Q
I
J 3 1
K P Q
I
1 2 mounting holes: 5.3 mm dia.; Spotfacing: 9 mm dia., depth 5 mm J
K
2 2 mounting holes: 6.5 mm dia.; Spotfacing: 11 mm dia., depth 6 mm
Weight
Type D E F I J K L M P Q
Monostable Bistable
11 (551) 27.5 33 50.5 61 112 133 32 45 9.5 12 0.28 0.36
12 (553) 40.2 16 78.5 74.6 134.5 162 51 72.3 12.1 19.4 0.80 1.06
D 78 106 134 162 190 218 246 D 117 158 199 240 281 322 363 1
2
Availability, design and specifications are subject to change without notice. All rights reserved.
07, bistable 1.0 1.4 1.9 2.3 2.7 3.1 3.5
D
G 3/8"
supply rail with isolation valves
19 12 12 with mounting brackets
3 3 3
3 3
2 2 2
2
139
2
149
1 1 1
1 1
87.5
23
92
75
65
10
E (551 Series)
C 35
4 Ø6.5 60
B 50
87
A 82