0% found this document useful (0 votes)
108 views7 pages

Catalog Series 551 553 Alu 1 4 1 2 3 2 80087 Asco en 6316780

The ASCO™ Spool Valves (Series 551-553) are 3/2 NC valves available in single or dual solenoid configurations, designed for pilot or air operation, and are compliant with IEC 61508 standards. They feature an aluminum body with threaded port connections, environmental protection against liquids and dust, and are suitable for applications in sensitive environments such as clean rooms and food processing. The valves come with various options for power levels, electrical connections, and installation requirements, ensuring versatility in usage.

Uploaded by

Suvo Khanra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
108 views7 pages

Catalog Series 551 553 Alu 1 4 1 2 3 2 80087 Asco en 6316780

The ASCO™ Spool Valves (Series 551-553) are 3/2 NC valves available in single or dual solenoid configurations, designed for pilot or air operation, and are compliant with IEC 61508 standards. They feature an aluminum body with threaded port connections, environmental protection against liquids and dust, and are suitable for applications in sensitive environments such as clean rooms and food processing. The valves come with various options for power levels, electrical connections, and installation requirements, ensuring versatility in usage.

Uploaded by

Suvo Khanra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

ASCO™ Spool Valves 3/2 NC

single/dual solenoid (mono/bistable function) - pilot operated or air operated SERIES


aluminium body - 1/4” and 1/2” tapped 551 - 553

Features
12 2 12 2 10

• The monostable spool valves in conformity with IEC 61508 Standard (2010 route 2H
3 1 3 1
2
2
version) have TÜV (551 series) and EXIDA (551-553 series) certified with integrity
levels: SIL 2 for HFT = 0 / SIL 3 for HFT = 1 12 3 1
12 3 1 10

• The spool valves 3/2 NC have threaded port connections


• All the exhaust ports of the spool valve are connectable, providing better
environmental protection. Particularly recommended for sensitive areas, such as
clean rooms, and applications in the pharmaceutical and food processing sectors
• The valve offers environmental protection against the ingress of liquids, dusts or
any other foreign matter (environmentally-protected construction)
• Epoxy moulded coil for general service applications
• The solenoid valves satisfy all relevant EU Directives

General
Differential pressure 2 - 10.4 bar [1 bar =100 kPa]
Flow (Qv at 6 bar) 1/4” = 860 l/min (ANR)
1/2” = 3800 l/min
Fluids () Temperature range (TS) Seal materials ()
air, inert gas, filtered -25°C to +60°C NBR (nitrile) + PUR (polyurethane)

Materials in contact with fluid


() Ensure that compatibility of materials in contact with fluids is verified.
Body Aluminium, black anodised 2
End cover (spring return) Glass-filled PA
Spool valve internal parts Zamak, stainless steel, POM, aluminium
Seals NBR + PUR
Core tube Brass
Core and plugnut Stainless steel
Shading coil Copper 3 1

Air operated specifications


Operating pressure
Flow differential (bar) BP
Pipe Orifice Basic
coefficient Prefix
size size Max. (PS) catalogue MP
Kv optional
Min. Air () number
RP
() (mm) (m3/h) (l/min) -
LP
Pilot air operated - spring return (monostable)
Not Not
1/4” 6 0.75 12.5 2 10 - 551A105 (1)
available 2.5W - 4W available 5W - 6.9W
1/2” 13 3.15 52.5 2 10 - 553A105 (1) Low Reduced Medium Basic
Pilot air operated and return (bistable) power power power power

1/4” 6 0.75 12.5 2 10 - 551A106 POWER LEVELS - cold electrical holding values (watt)
1/2” 13 3.15 52.5 2 10 - 553A106

Pilot operated specifications


Operating pressure
Flow Prefix optional solenoids
Pipe Orifice differential (bar) Power Basic
coefficient
size size Max. (PS) level NEMA ATEX / IECEx catalogue
Kv IP65
Min. Air () 7 & 9 Ex e mb Ex mb number
() (mm) (m3/h) (l/min) ~ = ~/= EF (2) WBLP PV SC
Solenoid air pilot operated - spring return (monostable)
RP - l l l 551A005 (1)
1/4” 6 0.75 12.5 2 10 10
BP l - - - 551A005 (1)
RP-BP - l l l 553A005 (1)
1/2” 13 3.15 52.5 2 10 10
BP l - - - 553A005 (1)
Solenoid air pilot operated and return (bistable)
RP - l l l 551A006
1/4” 6 0.75 12.5 2 10 10
BP l - - - 551A006
RP-BP - l l l 553A006
1/2” 13 3.15 52.5 2 10 10
BP l - - - 553A006
 Select 8 for NPT ANSI 1.20.3 or select G for ISO G (228/1) l Available feature - Not available
80049GB-2022/R01

(1)
Certified IEC 61508 Functional Safety data, use suffix "SL".
(2)
UL CSA

Visit our website at Emerson.com/ASCO 1


3/2 NC
SERIES
551 - 553

Prefix table Product selection guide


Prefix Power level STEP 1
Description
1 2 3 4 5 6 7 LP RP MP BP Select basic catalogue number,
E F Explosionproof - NEMA 7, 9 - Zinc plated steel conduit including pipe thread indentification
- - - l
(18” continuous leads) letter. Refer to the specifications table
E F H T EF (18” continuous leads) + high temperature - - - l on page: 1
E F H T L EF + high temperature + 72" continuous leads - - - l Example: G551A005
E F L EF + 72" continuous leads - - - l
J B E F EF + Junction box (conduit in 1/2" NPT) - - - l STEP 2
J B E F M F EF + Junction box (conduit in 1/2" NPT) + surge suppression coils - - - l Select prefix (combination). Refer
J C E F EF + Junction box (conduit in 3/4" NPT) - - - l to the specifications table and the
J C E F H T EF + Junction box (conduit in 3/4" NPT) + high temperature - - -
prefix table, respect the indicated
l
P V Encapsulated epoxy moulded (EN/IEC 60079-18)* - l - l
power level.
W B L P I.S./encapsulation with PBT IP67 enclosure
(EN/IEC 60079-7, -18, -31)*
- l - - Air operated version, does not use
- -
prefix.
S C Solenoid with spade plug connector (EN/IEC 60730) l l
X Other special constructions - l - l Example: SC

STEP 3
Suffix table Select suffix (combination) if required.
Suffix Power level Refer to the suffix table, respect the
Description
1 2 3 4 5 LP RP MP BP indicated power level.
G D Non-electrical, 2 GD, construction safety, gas/dust
- - - - GD suffix available for air operated
(EN ISO 80079-36/37) version only (do not use manual
M S Screw type manual operator - l - l operator suffix).
S L Certified IEC 61508 Functional Safety data (1) - l - l Example: MS

STEP 4
Select voltage. Refer to standard
voltages on page: 3
Example: 230V / 50Hz

STEP 5
Final catalogue / ordering number
Example:
SCG551A005MS 230 V / 50 Hz

Options and Accessories Ordering examples valves:


Exhaust protector SC G 551 A 005 MS 230V / 50 Hz
Pipe (stainless steel)
Series PV 8 551 A 006 115V / 50 Hz
size
G NPT (M) WBLP G 553 A 005 MS 24V / DC
551 1/4” 34600419 (2) 34600483 (2) - G 553 A 106
553 1/2” 34600479 (2) 34600481 (2) - G 551 A 106 GD
551/553 M5 - - 34600484 (2) G 551 A 105 GD SL
 Available feature SC G 551 A 005 SL
- Not available
* ATEX/IECEx valves using these solenoids are approved according to prefix
EN ISO 80079-36 (2016) and EN ISO 80079-37 (2016) [non electrical] pipe thread voltage
(1)
Not to use with MS suffix suffix
basic number
(2)
Provided with "SL" suffix
80049GB-2022/R01

2 Visit our website at Emerson.com/ASCO


3/2 NC
SERIES
551 - 553

Explanation of temperature ranges of solenoid valves


Valve temperature range The valve temperature range (TS) is determined by the selected seal material, the
temperature range for proper operation of the valve and sometimes by the fluid (e.g.
steam)
Operator ambient temperature The operator ambient temperature range is determined by the selected power level
range and the safety code
Total temperature range The temperature range of the complete solenoid valve is determined by the limitations
of both temperature ranges above

Electrical characteristics
Coil insulation class F
Electrical safety IEC 335
Standard voltages DC (=) 24V - 48V
AC (~) 24V - 48V - 115V - 230V/50Hz; other voltages and 60Hz are available on request
Power ratings Operator Electrical
ambient Replacement coil
Prefix Inrush Holding Hot/Cold temperature enclosure Type
Safety code
option = range (TS) protection = (1)
~ ~ ~
(VA) (VA) (W) (W) (C°) (EN 60529) 230 V/50 Hz 24V/DC
Basic power (BP)
SC 15 7 5 4/5 -25 to +60 EN 60730 IP65, moulded 400727-117 400727-185 02
PV - - 6.3 - -40 to +65 II2G Ex mb IIC T3 Gb,II2D Ex mb IIIC Db IP67 moulded - (2) - (2) 04
PV - - - 6.9 -40 to +40 II2G Ex mb IIC T3 Gb,II2D Ex mb IIIC Db IP67 moulded - (2) - (2) 04
EF 55 23 10.5 9/11.2 -40 to +52/40 NEMA type 7 and 9 NEMA 4X - - 07-08
EFHT 55 23 10.5 9/11.2 -40 to +52/40 NEMA type 7 and 9 NEMA 4X - - 07-08
JBEF 55 23 10.5 9/11.2 -40 to +52/40 NEMA type 7 and 9 NEMA 4X - - 09-10
JBEFHT 55 23 10.5 9/11.2 -40 to +52/40 NEMA type 7 and 9 NEMA 4X - - 09-10
Reduced power (RP)
SC 6 3.5 2.5 2.5/3 -25 to +60 EN 60730 IP65, moulded 400127-097 400904-542 01
PV - - 4 - -40 to +60/65 II2G Ex mb IIC T4-T3 Gb,II2D Ex mb IIIC Db IP67 moulded - (2) - (2) 03
PV - - - 3 -40 to +40/60/60 II2G Ex mb IIC T5-T4-T3 Gb,II2D Ex mb IIIC Db IP67 moulded - (2) - (2) 03
WBLP - - 3.5 -/4 -40 to +65 II2G Ex e mb IIC T4 Gb, II2D Ex tb IIIC Db IP67 PBT - (2) - (2) 05-06
(1)
Refer to the dimensional drawings on pages: 4 to 5 (Air operated versions: Refer to the dimensional drawings on pages: 7).
(2)
Multiple coil kits are available under ATEX/IECEx, contact us

Electrical connections
Prefix Connection
SC Type 01: Spade plug connector with cable gland DIN 43650, 11 mm, industry standard B, for cables with an outer diameter from 6 to
8 mm
Type 02: Spade plug connector with cable gland EN175301-803A (ISO 4400) for cables with an outer diameter from 6 to 10 mm
PV Moulded-in cable, standard length 2 m
WBLP M20 cable gland for cables with an outer diameter from 7 to 8,5 mm
EF 1/2" NPT conduits
JBEF EF + Junction box

Additional options
• Other pipe threads are available on request
• Ex mb (prefix "PV") solenoid can be supplied with various cable lengths

Installation
• Multi language installation/maintenance instructions are included with each valve
• The valves can be mounted in any position without affecting operation
• Do not connect the pressure supply to the exhaust port 3. The “environmentally-protected” construction is not
adapted for a “distributing” function or use in NO function. Contact us for functions available in specific versions
• IEC 61508 Functional Safety (suffix SL). Check temperature range of valve body and solenoid for suitability. For prob-
ability of failure, contact us
• It is necessary to connect pipes or fittings to the exhaust ports to protect the internal parts of the spool valve and
its pneumatic operator if used outside or in harsh environments (dusts, liquids etc.)
• Threaded pipe connection identifier is 8 = NPT (ANSI 1.20.3); G = G (ISO 228/1)
80049GB-2022/R01

Visit our website at Emerson.com/ASCO 3


3/2 NC
SERIES
551 - 553

Dimensions (mm), Weight (kg)


TYPE 01: TYPE 02:
Epoxy moulded Epoxy moulded
SC: IEC 335 / ISO 4400 SC: IEC 335 / ISO 4400

551A005 / A005MS / A006 / A006MS 553A005 / A005MS / A006 / A006MS

=
= =
D

D
3 2 1 3 2 1

=
3 x 1/4”
F E F E 3 x 1/2”

N
2 90°
N

180° 1
0
G

=
O

O
=
=

2
=
360°

M
360°
M
L

L
3 1
=
=

=
M5

=
M5
P Q 1 0
3 1
1 P Q
I
I
J J
H K H
H K H

TYPE 03: TYPE 04:


Epoxy encapsulated Epoxy encapsulated
PV: EN/IEC 60079-18 PV: EN/IEC 60079-18

551A005 / A005MS / A006 / A006MS 553A005 / A005MS / A006 / A006MS

=
D
= =
= =
D1
D

3 2 1

=
3 2 1
3 x 1/4" 3 x 1/2”
F E
F E
2

N
1 2
N

=
G

=
=

2
O
=

360°

M
M

O
L
L

3 1
=
=

=
=

M5
PQ 1
3 1
0
I 1 P Q
I
J J
K
K

TYPE 05: TYPE 06:


PBT PBT
WBLP: EN/IEC 60079-7 +18 + 31 WBLP: EN/IEC 60079-7 +18 + 31

551A017/A017MS/A018/A018MS/A067/A067MS/A068/A068MS 553A017/A017MS/A018/A018MS/A067/A067MS/A068/A068MS
=
=
D1
D
=
= =
D1

=
D

3 2 1
=

3 2 1
=

3 x 1/4"
F E 3 x 1/2”
F E
N

2
2
N

1
G

0
O
O

=
=
=

2
360°
=

M
L
360°

80049GB-2022/R01
M
L

3 1
=

=
=

P Q 1 0
3 1
1 P Q
I I
J J
K K

4 Visit our website at Emerson.com/ASCO


3/2 NC
SERIES
551 - 553

Dimensions (mm), Weight (kg)


TYPE 07: TYPE 08:
Epoxy encapsulated Epoxy encapsulated
EF: NEMA type 7, 9 / ICS-6 ANSI EF: NEMA type 7, 9 / ICS-6 ANSI

551A005 / A005MS / A006 / A006MS 553A005 / A005MS / A006 / A006MS

=
=
D1
D
D1
= =

= =

=
D
3 2 1

=
3 2 1
3 x 1/4"
F E F E 3 x 1/2"
2
1
2
0

=
G
G

=
=

2
=

360°

M
360°

L
M
L

3 1
=
=

=
=
P Q 1
3 1
0

I 1 P Q
I
J J
K K

TYPE 09: TYPE 10:


Epoxy encapsulated Epoxy encapsulated
JBEF: NEMA type 7, 9 JBEF: NEMA type 7, 9

551A005 / A005MS / A006 / A006MS 553A005 / A005MS / A006 / A006MS


H1
H1

=
=

=
= =

D1
D1

D
D

3 2 1

=
3 2 1
=

=
3 x 1/4"
H F E H F E 3 x 1/2"
G
G

2
2
O

1
0
=
=
=

2
=

360°
360°

M
M

L
L

3 1
=
=

=
=

P Q 1
3 1
0
I 1 P Q
J I
K J
K
1 2 mounting holes: 5.3 mm dia.; Spotfacing: 9 mm dia., depth 5 mm
2 2 mounting holes: 6.5 mm dia.; Spotfacing: 11 mm dia., depth 6 mm
Connectable pilot exhaust port
Prefix/ Power
(1)
Weight
Type D D1 E F G H H1 I J K L M N O P Q
option level Monostable Bistable
01 (551) SC RP 27.5 - 33 83.5 52 13 - 93.5 145 198 32 45 27 72 9.5 12 0.35 0.43
02 (553) SC BP 40.2 - 16 114.2 59.2 21.8 - 111.6170.2233.3 51 72.3 20 92.3 12.1 19.5 0.69 0.99
03 (551) PV RP 27.5 29 33 83.5 36.5 13 - 93.5 145 198 32 45 13 58 9.5 12 0.37 0.49
04 (553) PV BP 40.2 - 16 114.2 36.5 21.8 - 110.6170.2233.3 51 72.3 0.3 92.3 12.1 19.5 0.72 1.02
05 (551) WBLP RP 27.5 37 33 83.5 81.5 - - 93.5 145 198 32 45 59 104 9.5 12 0.44 0.63
06 (553) WBLP RP 40.2 37 16 114.2 81.5 - - 110.6170.2233.3 51 72.3 45.35117.65 12.1 19.5 0.79 1.16
07 (551) EF BP 27.5 30.5 33 83.5 53 - - 93.5 145 198 32 45 - - 9.5 12 0.45 0.63
80049GB-2022/R01

08 (553) EF BP 40.2 87 16 114.2 53 - - 110.6170.2233.3 51 72.3 - - 12.1 19.5 0.89 1.19


09 (551) JBEF BP 27.5 30.5 33 83.5 151 13.5 225 93.5 145 198 32 45 - 187.15 9.5 12 1.34 2.44
10 (553) JBEF BP 40.2 87 16 114.2 151 13.5 261 110.6170.2233.3 51 72.3 - 187.15 12.1 19.5 1.84 3.14
(1)
Incl. coil(s) and connector(s).

Visit our website at Emerson.com/ASCO 5


3/2 NC
SERIES
551 - 553
Accessories (551/553 Series)
• Supply rail (supplied with seals and banjo bolts, without mounting brackets)
Catalogue number Mounting brackets
Supply rail (set of 2)
for "n" valves 551 Series 553 Series
G 1/4” NPT 1/4” G 1/2” NPT 1/2” 551 Series
2 88100034 88100053 88100759 88100766
catalogue number:
3 88100035 (1) 88100760 88100767 88100049
4 88100036 88100054 88100761 88100768
5 88100037 88100058 88100762 88100769 553 Series 2

6 88100038 88100055 88100763 88100770 catalogue number:


7 88100039 88100059 88100764 88100771 88100773
8 88100040 88100060 88100765 88100772
(1) Available on request.

Supply rail with isolation valves with mounting brackets


(Allows the isolation of one or more valves from the general pressure supply)

Supply rail Catalogue number


supply rail with isolation
for "n" valves valves
G 1/4” NPT
2 88100915 - with mounting brackets
3 88100916 -
4 88100917 -
5 88100918 -
72

6 88100919 - 65
7 88100920 -
10

8 88100921 -
9 88100922 - 1/4 (551 Series)
10 88100923 -
11 88100924 -
12 88100925 -

Number of valves Number of valves


551 Series 553 Series
2
3 4 5 6 7 8 2 3 4 5 6 7 8
A 108
136 164 192 220 248 276 A 136 117 218 259 300 341 382
B 92
120 148 176 204 232 260 B 116 157 198 239 280 321 362
C 55
83 111 139 167 195 223 C 81 122 163 204 245 286 327
D 78
106 134 162 190 218 246 D 117 158 199 240 281 322 363
E 42
70 98 126 154 182 210 Type Weight (kg)
Type Weight (kg) 02, monostable 2.1 2.9 3.8 4.7 5.6 6.4 7.4
01, monostable 0.9 1.3 1.7 2.0 2.4 2.9 3.3 02, bistable 2.5 3.6 4.8 5.9 7.1 8.1 9.3
01, bistable 1.2 1.7 2.1 2.6 3.1 3.6 4.1
D Supply rail with
G 3/8" (551) isolation valves
G 3/4" (553) 360°
(551-553)
180°

(551)
12
19 (551)
194 (551)

27 (553)
181 (551)
238 (553)

184
260 (553)

3 3 3 3
148 (551)

2 2 2 2
202 (553)

1 1 1 1
92 (551)

551
127.5 (553)
87 (551)
75 (551)
134 (553)

23 (551)
108 (553)

65

32 (553)

E
35 (551) 60
C 4Ø 6.5 (551)
B 52 (553)
4Ø 9 (553)
50 (551)
A (551 Series)
82 (551) 75 (553) 30 (551)
113.3 (553) 23 (553)
This mounting arrangement allows valves to be mounted in the positions bellow.
Not possible with supply rail Only with supply rail
and isolation valves with isolation valves
(551-553) (551)
2 (551-553) (551-553)
(551-553) (551-553) (551 Series) 2
(551) (551)
80049GB-2022/R01
216.3 (553)

2 2
159 (551)

(551)
196.3 (553)
132 (551)

6 Visit our website at Emerson.com/ASCO


3/2 NC
SERIES
551 - 553
Dimensions (mm), Weight (kg)
TYPE 11: TYPE 12:
No prefix, IP65 No prefix, IP65
Suffixes: GD (II 2 GD) ; SL (SIL) ; Suffixes: GD (II 2 GD) ; SL (SIL) ;
GDSL (SIL, II 2 GD)] GDSL (SIL, II 2 GD)]
Air operated version Air operated version

551A105 / 551A106 553A105 / 553A106

=
=
D

D
=
3 2 1
3 2 1

=
3 x 1/4"
F E
F E 3 x 1/2"
G1/8" 2
2
G1/4"
=

2
=

=
M
L

=
12 3 1 10
=

M
L
=
1

=
P Q
I
J 3 1
K P Q
I
1 2 mounting holes: 5.3 mm dia.; Spotfacing: 9 mm dia., depth 5 mm J
K
2 2 mounting holes: 6.5 mm dia.; Spotfacing: 11 mm dia., depth 6 mm
Weight
Type D E F I J K L M P Q
Monostable Bistable
11 (551) 27.5 33 50.5 61 112 133 32 45 9.5 12 0.28 0.36
12 (553) 40.2 16 78.5 74.6 134.5 162 51 72.3 12.1 19.4 0.80 1.06

Accessories (551/553 Series)


• Supply rails: (See catalogue numbers on preceding page)
Number of valves Number of valves
551 Series 553 Series
2 3 4 5 6 7 8 2 3 4 5 6 7 8
A 108 136 164 192 220 248 276 A 136 117 218 259 300 341 382
B 92 120 148 176 204 232 260 B 116 157 198 239 280 321 362
C 55 83 111 139 167 195 223 C 81 122 163 204 245 286 327 3

D 78 106 134 162 190 218 246 D 117 158 199 240 281 322 363 1
2

E 42 70 98 126 154 182 210 Type Weight (kg)


Type Weight (kg) 08, monostable 2.3 3.0 3.8 4.7 5.5 6.3 7.2
07, monostable 0.9 1.2 1.5 1.9 2.2 2.5 2.8 08, bistable 2.5 3.5 4.6 5.7 6.7 7.7 8.7

Availability, design and specifications are subject to change without notice. All rights reserved.
07, bistable 1.0 1.4 1.9 2.3 2.7 3.1 3.5
D
G 3/8"
supply rail with isolation valves
19 12 12 with mounting brackets
3 3 3
3 3
2 2 2
2
139

2
149

1 1 1
1 1
87.5

23
92
75

65

10

E (551 Series)
C 35
4 Ø6.5 60
B 50
87
A 82

This mounting arrangement allows valves to be mounted in the positions bellow.


Only with supply rail with
2 Not possible with supply rail isolation valves
2
and isolation valves
2 2 (551 Series)
80049GB-2022/R01
132

Visit our website at Emerson.com/ASCO 7

You might also like