Escáner Lineal 2

The HUC-260 is a linear array probe with a center frequency of 7.5MHz and 80 arrays, designed for clinical ultrasonic diagnostic examinations. It features a mean sensitivity of -47.3dB and a focal distance of 20±3mm. The document also includes specifications for installation and operation procedures for the probe.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views4 pages

Escáner Lineal 2

The HUC-260 is a linear array probe with a center frequency of 7.5MHz and 80 arrays, designed for clinical ultrasonic diagnostic examinations. It features a mean sensitivity of -47.3dB and a focal distance of 20±3mm. The document also includes specifications for installation and operation procedures for the probe.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Machine Translated by Google

HUC-260
Probe specification sheet
Machine Translated by Google

Product name: Linear probe


Model: HUC-260

General specifications
project specifications

Probe type linear array

center frequency 7.5MHz

Number of arrays 80

Array spacing 0.501mm

focal distance
20±3mm

Horizontal aperture 4.2mm

Acoustic specifications
project specifications

Mean sensitivity -47.3dB

Sensitivity deviation
±1dB

-6dB, center frequency


7.5±10% MHz

-6dB relative bandwidth >65%


mean

Test condition:

project specifications

water temperature
25ÿ

impulse source
Olympus 5052PR (Damping 50ÿ)
Machine Translated by Google

Target blocks A smooth steel plate 20mm from the


surface of the lens

Electrical specifications

project specifications

The circuit matches the -


inductor

Mechanical specifications

The size of the probe end is shown in the figure below, unit mm.

The size of the cable part is shown in the figure below, unit mm.

Installation of Probe
Machine Translated by Google

Operation procedure:
1. Take the probe from the package, put it on the probe holder tenderly.
2. Put the probe connectors firmly with the host of the connector socket. ÿPay
attention to the direction, the tail line down). Be careful not to let the cable drag on
the floor.
3. Insert the probe connector firmly into the connector socket on the main unit-take
care of the direction.After plug into the connector correctly, move the toggle lock
towards left side to lock it, and fix probe; move the toggle lock towards right side to
unlock it, remove the probe.

Scope of Application
This instrument is used for clinical ultrasonic diagnostic examination.

Signed:

Name: Alice
Title: : Sales Director