Fanuc Opc Server Operator's Manual
Fanuc Opc Server Operator's Manual
Operator’s Manual
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 1/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Contents
I. GENERAL ............................................................................................................................................................ 9
1 GENERAL ......................................................................................................................................................... 10
1.1 COMPOSITION ..................................................................................................................................... 10
1.2 CNC Model name ................................................................................................................................... 10
1.3 RELATED MANUALS........................................................................................................................... 11
2 OVERVIEW OF FANUC OPC SERVER .............................................................................................................. 14
2.1 Introduction to FANUC OPC Server .................................................................................................... 14
2.2 Supported CNC ...................................................................................................................................... 14
2.3 Supported CNC data .............................................................................................................................. 15
2.4 Number of Point ..................................................................................................................................... 15
2.5 Update Time of Point ............................................................................................................................. 15
2.6 PC Hardware .......................................................................................................................................... 16
2.7 Supported Windows OS ......................................................................................................................... 16
Ⅱ. INSTALLATION.............................................................................................................................................. 17
1 INSTALLATION ................................................................................................................................................. 18
1.1 Shipping Items ....................................................................................................................................... 18
1.2 Preparation ............................................................................................................................................. 18
1.3 Installation ............................................................................................................................................. 19
1.4 Registration of serial number................................................................................................................ 24
1.5 Firewall Inbound Rules ......................................................................................................................... 26
2 UN-INSTALLATION ........................................................................................................................................... 28
Ⅲ. CONFIGURATION.......................................................................................................................................... 29
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 2/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 3/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
SAFETY PRECAUTIONS
"SAFETY PRECAUTIONS" describes the safety precautions related to the use of CNC units, to ensure safe
operation of machines fitted with FANUC OPC Server and FANUC CNC units. Read this section carefully
before attempting to use any function described in this manual.
Users should also read the relevant descriptions in the Operator’s Manual of the CNC to become fully familiar
with the functions to be used.
Contents
DEFINITION OF WARNING, CAUTION, AND NOTE ............................................................................ 4
GENERAL WARNINGS AND CAUTIONS ............................................................................................... 6
GENERAL WARNINGS FOR CNC APPLICATION DEVELOPMENT .................................................. 7
WARNING
Applied when there is a danger of the user being injured or when there is a
danger of both the user being injured and the equipment being damaged if the
approved procedure is not observed.
CAUTION
Applied when there is a danger of the equipment being damaged, if the approved
procedure is not observed.
NOTE
The Note is used to indicate supplementary information other than Warning and
Caution.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 4/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 5/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
CAUTION
1 Immediately after switching on the power, do not touch any of the keys on the
MDI unit until the position display or alarm screen appears on the CNC unit.
Some of the keys on the MDI panel are dedicated to maintenance or other
special operations. Pressing any of these keys may place the CNC unit in other
than its normal state. Starting the machine in this state may cause it to behave
unexpectedly.
2 The operator's manual for the CNC describes all the basic functions of the CNC,
including the optional functions. The selected optional functions vary with the
machine. Some functions described in this manual may not, therefore, be
supported by your machine. Check the machine specifications before using the
optional functions.
3 Some machine operations and screen functions are implemented by the machine
tool builder. For an explanation of their usage and related notes, refer to the
manual provided by the machine tool builder.
For example:
• On some machines, executing a tool function causes the tool change unit to
operate. When executing a tool function on such a machine, stand well clear
of the tool change unit. Otherwise, there is a danger of injury to the operator.
• Many auxiliary functions trigger physical operations, such as rotation of the
spindle. Before attempting to use an auxiliary function, therefore, ensure that
you are fully aware of the operation to be triggered by that function.
NOTE
Command programs, parameters, and variables are stored in nonvolatile memory
in the CNC. Generally, the contents of memory are not lost by a power on/off
operation. However, the contents of memory may be erased by mistake, or
important data in nonvolatile memory may have to be erased upon recovering
from a failure. To enable the restoration of data as soon as possible if such a
situation arises, always make a backup of the data in advance.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 6/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
WARNING
1 Be careful enough if you write an identical CNC data, an identical PMC data or a
series of related data set by two or more above applications including network
functions. Because they are executed based on each individual cycles (in other
words, asynchronous cycles), there is a possibility that the data will be written in
an unexpected order.
Therefore, do NOT write above data in the following cases.
- Applications and network functions
- Two or more applications
- Two or more network functions
Data, applications and network functions of interest are listed in below. However,
all may not be listed completely because new features will be added in the future.
2 Be careful enough that you must prevent PMC signals in the same byte from
being written by the following two or more applications including network
functions. While an application reads and writes one byte of PMC signals, other
applications may write the same byte.
3 Be careful enough if you process a PMC signal set that is related to a CNC
function by using the following two or more applications including network
functions. Because they are executed based on each individual cycles (in other
words, asynchronous cycles), there is a possibility that the CNC may receive the
PMC signal set in an unexpected order.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 7/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
WARNING
4 Generally, when multi-byte data are read or written at once among the following
two or more applications including network functions, the coherency of the read
multi-byte data (in other words, reading all latest data at once) is not guaranteed.
To ensure the coherency of the multi-byte data, prepare flags to notify the
completion of reading or writing process that is separated from the entity of the
data and make the handshaking process to access the data by using the flags.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 8/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
I. GENERAL
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 9/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
1 General
This chapter explains the organization of this manual and how to read this manual.
1.1 COMPOSITION
This manual consists of the following parts:
SAFETY PRECAUTIONS
This section describes the precautions to be observed when reading this manual.
I. GENERAL
This part describes the chapter organization, applicable models, related manuals, and general of the
FANUC OPC Server.
II. INSTALLATION
This part describes how to install and uninstall. Please read carefully before installation.
III. SETTING
This part describes the setting items necessary to use each function.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 10/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 11/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 12/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 13/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 14/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
・ Series 0i-B/C
・ PowerMate i-D/H
NOTE
The performance of the OPC server depends on the following conditions. The
performance means how many points can be renewed at how much intervals.
- The performance of the PC where OPC Server runs
- Number of connected CNC and OPC client
When deciding the above-mentioned conditions, please execute the preliminary
test to confirm that the performance of OPC Server achieves the necessary
performance.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 15/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
2.6 PC Hardware
The following list details the appropriate hardware environment for the software.
ITEM MINIMUM RECOMMENDED
PROCESSOR Single-core processor, 1.6Ghz Quad-core processor, 2.8Ghz
RAM 1GByte 4Gbyte
HARD DISK 100Mb of free hard disk space 100Mb of free hard disk space
NETWORK 100base-T Ethernet adapter 100base-T Ethernet adapter
VIDEO 1024×768 1280×1024
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 16/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Ⅱ. INSTALLATION
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 17/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
1 Installation
This chapter describes the software installation of FANUC OPC Server software.
1.2 Preparation
This tool communicates with CNC by using the TCP/IP protocol of Ethernet.
At the PC where you install this tool, please confirm the followings.
- TCP/IP function is installed.
- IP address, subnet mask, and if necessary the default gateway, of the PC are specified.
- If your computer is not connected to the Internet, to disable the check for publisher's certificate revocation
of digital signature.
Open the [Control Panel], click the [Internet Options], Open the Internet Properties.
Select the [Advanced] tab, uncheck the [check for publisher's certificate revocation], and then click the
[OK] button
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 18/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
NOTE
On a PC that does not connect to the Internet, if that is the check box for [Check for
publisher's certificate revocation], it takes a long time to start of FANUC OPC
Configurator.
1.3 Installation
This section details the steps of software installation for the Windows 7 operating system. Installation for other
OS is almost the same.
NOTE
1 To install the software, you must have the administrator user name and
password.
2 Before installing, please close all running programs.
3 The following software is used. If it is not installed, it is installed automatically.
- Microsoft .NET Framework 4 Client Profile
- Microsoft .NET Framework 4 Extended
- Microsoft Visual Studio C++ 2010 x86 Redistributable
- Windows Installer 4.5 for Windows XP SP2 and later (x86) (Windows XP only)
The standard installation steps install both the FANUC OPC Server and the FANUC OPC Configurator, the
configuration tool for the OPC Server.
When "Custom" installation is selected, you can;
- Install FANUC OPC Configurator only
- Change the installation folder.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 19/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
1) Insert the installation media to the PC. The installer will automatically start.
If the installer does not start, please start the setup.exe in the installation media by using Windows Explorer.
When the following window appears, click the [Install] button. The required software is installed.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 20/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
3) The license agreement window appears. Please read the agreement carefully.
When you agree, click [I accept the terms in the licensee agreement], then click [Next] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 21/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
5) Setup Type selection window appears. Usually, select "Complete" and then click the [Next] button.
The sequence proceeds to step 6.
In the following cases, select the "Custom" and then click the [Next] button.
A) You install OPC Configurator only, and do not install OPC Server.
B) You change the folder to install the software.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 22/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
A)
B)
A) If you do not install the FANUC OPC Server, click the icon of FANUC OPC Server, and then select
[This feature will not be available].
B) If you change the installation folder, click [Change…] button to change the folder to install the
software.
6) If you click the [Install] button on the following window, the installation starts.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 23/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
1) To open the FANUC OPC Registration window, click [START], [PROGRAMS], [FANUC OPC Server]
and then [FANUC OPC Registration].
2) The figure number for which the input of the serial number is necessary is displayed on the screen.
Click the [OK] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 24/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
3) Enter the serial number and then click the [Save] button.
5) If the entered serial number is displayed on the screen, the registration is completed.
Click the [End] button to exit the window.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 25/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
1) Open [Control Panel], Click [Windows Firewall], and then [Advanced Setting] Click.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 26/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
NOTE
Rules Please be set to both TCP and UDP.
3) Check the profile to be applied in the profile section of the Advanced Settings.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 27/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
2 Un-installation
You can uninstall FANUC OPC Server from the [Programs and Features] in the [Control Panel] of Windows.
NOTE
Before you uninstall the software, please make sure that the FANUC OPC Server
is not running. When it is running, please terminate it with the following steps.
If the service mode is running, you do not need termination.
1) Please confirm whether an icon of OPC server is displayed in the system tray
of Windows. The details of the procedure are described in "4.1 Display of
OPC Server user interface" in "III. Configuration".
2) Please terminate the OPC Server when the icon is displayed.
- Double click the icon to restore it to the normal size.
- Click the [File] menu, and then click the [Force Server Exit] in the
drop-down menu.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 28/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Ⅲ. CONFIGURATION
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 29/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
1 Quick guide
This chapter explains the necessary setting procedure of Ethernet communication and OPC Configurator to read
and write PMC data of CNC from OPC Client.
The following system example is used in explanation.
Equipment IP ADDRESS
PC for OPC Server 192.168.1.1
CNC 192.168.1.213
SUBNET MASK 255.255.255.0
ROUTER IP ADDRESS 192.168.1.250
NOTE
The above setting is an example. For details on IP addresses, subnet mask and
router IP address, consult with the administrator of the network.
Setting of CNC
Below is the setting procedure of connecting Series 30i-B CNC to the PC with Embedded Ethernet.
The setting procedure is different in each CNC. For details, please refer to the manual of each CNC.
1) Press function key .
2) Soft key [EMBED PORT] appears. When the soft key does not appear, press the continue key.
3) Enter the value "192.168.1.213" to [IP ADDRESS], "255.255.255.0" to [SUBNET MASK] and
"192.168.1.250" to [ROUTER IP ADDRESS].
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 30/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
4) Press soft key [FOCAS2]. Enter the value "8193" to [PORT NUMBER (TCP)], 0 to [PORT NUMBER
(UDP)] and [TIME INTERVAL].
If the response message "Reply from…" is not received, confirm that the network switch and cables are
connected appropriately and the IP addresses of CNC and PC are correct.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 31/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 32/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 33/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 34/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
1) Right-click the icon "TEST_30iB" in OPC Explorer window, and select [Add Point: TEST_30iB] on the
pop-up menu. Point Configuration Wizard appears.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 35/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 36/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 37/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Select the items as follows and click the [Next >>] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 38/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Enter "PMC_1B_R0000_02" in the "Point Name" field, and click the [Done] button.
7) Point Configuration Wizard is finished and the created point is displayed in OPC Explorer.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 39/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 40/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Confirm that [localhost] is displayed in the "Server PC Name / IP Address" field, and then click the
[Connect] button.
The message, "Connection Successful", shows that the connection to the OPC Server succeeded.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 41/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 42/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
4) Server Properties window is closed and [FANUCOPC.SERVER.0] is displayed on the left area of the main
window. It means that the client is connected to OPC Server.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 43/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
7) Group Properties window is closed, and added group [TEST_30iB] is displayed under
[FANUCOPC.SERVER.0].
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 44/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
9) [PMB_1B_R0000_02] is displayed in [Item ID] of the Main windows. Its value is displayed in [Value].
If the value of R0000 equals 1 and R0001 equals 2, "[1, 2]" is displayed in [Value].
10) Save the settings. Click the menu [File], [Save As…].
Save as dialog appears. Save the settings in any folder.
11) The saved settings can be read by Open dialog. To display the Open dialog, click the menu [File], [Open].
After reading the configuration from the file, it is connected to the specified OPC Server automatically.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 45/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
FANUC OPC Server reads the settings from the configuration file for operation, and it works according to the
contents of it.
The folder and file name of the configuration file for operation are fixed.
OS Configuration file for operation
Windows XP C:¥Documents and Settings¥All Users¥Application Data¥FANUC¥OPCServer¥FASOPC.fs2
Windows 7 C:¥ProgramData¥FANUC¥OPCServer¥FASOPC.fs2
or later
FANUC OPC Configurator can preserve the created setting data in an arbitrary folder by an arbitrary name. The
default folder to preserve the setting data is the following places.
OS Default folder to preserve the setting data
Windows XP C:¥Documents and Settings¥All Users¥Application Data¥FANUC¥OPCUI
Windows 7 C:¥ProgramData¥FANUC¥OPCUI
or later
The configuration data currently opened by the FANUC OPC Configurator can be overwritten to the
configuration file for operation by "Export" procedure. As a result, the setting of the OPC Server can be
changed.
The name of the file created by the "Export" procedure is fixed as "FASOPC.fs2". The folder of it can be
specified.
If OPC Server and OPC Configurator run on the same PC, please specify the folder of the configuration file for
operation in "Export" procedure. Then, the configuration of the OPC Server can be changed.
FANUC FANUC
OPC Server OPC Configurator
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 46/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
If OPC Server and OPC Configurator run on the different PC, export the settings to the arbitrary folder, and then,
copy the file by hand to the PC where OPC Server runs.
FANUC FANUC
OPC Server OPC Configurator
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 47/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
3 OPC Configurator
This chapter explains the details of OPC Configurator, the setting tool of OPC Server.
CAUTION
Before performing communication using the OPC Server for the first time, consult
with your network administrator, carefully set a network address and other items,
and conduct communication tests thoroughly. Any error in settings such as a
network address setting can lead to an adverse influence such as a
communication failure on the entire network. Be very careful about any
communication failure. The load on the network may become greater than
expected depending on the performance of the personal computer. Before using
the functions, completely confirm that there is no problem with the entire system
including communication with the personal computer.
CAUTION
1 In the PMC area, the R area, and E area in volatile memory are all set to 0
immediately after power-on.
2 The E area in the PMC area is normally allocated to volatile memory. However, it
can also be used as nonvolatile memory by setting the option.
When the area is used as nonvolatile memory, the contents of the area are
retained even after the power is turned off. So, special attention should be paid
not to cause an unpredictable operation when the power is turned on next time.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 48/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
The views are dockable and can be arranged to the users liking by dragging them within the parent form.
The Data View, Server Status, and Property View may be also float outside of the parent form.
The procedure to restore the size and place to the default settings is as follows.
1) Click [TOOLS] on the top menu.
2) Click [DEFAULTS], [Reset All Views] on drop-down menu.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 49/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Configuration file
Machine
CNC/PMC Path
Point
3.3.3 Refresh
The Refresh View button [ ] initiates a manual refresh of the OPC Explorer view. If a new element has been
added the view will automatically refresh.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 50/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Clicking the button to the left of any element will collapse only of the relative sub-elements.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 51/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
To view the FANUC OPC server status information, the server must be connected.
Please connect to the OPC Server with the procedure described in "1.3 Confirming OPC Server Operation" of "
Ⅲ. CONFIGURATION".
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 52/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 53/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 54/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
3) Enter the "Machine Name", which can be any name the user wants. This will be the primary node name
displayed in explorer view. The character that can be used is an alphanumeric character, under bar, and
hyphen.
4) Enter the "Machine Description", this will appear in the property view window.
Click the [Next>>] button to advance to the next tab.
5) The Configure Ethernet Control tab appears in the wizard.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 55/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
11) Select the "Control Types", series and model in the drop-down box.
12) Select the "Machine Type" for the CNC Control from [M] or [T]. When [30i], [31i], [32i] or [35i] is
selected at "Control Types", "Machine Type" cannot be selected.
13) Select the "PMC Paths", the number of PMC Path.
14) Select the "CNC Paths", the number of CNC Path.
Click the [Next>>] button to advance to the next tab.
16) Enter the name of CNC Path in the "Name" field. This value is displayed at the CNC Path in CNC
Explorer, and the item "Description" in Property View.
17) Select the "Machine Type" for the CNC Path from [M] or [T]. When [0iD], [0iF], [PMiA] ,[PMiH] or
[PMiD] is selected at "Control Types" in Control Information tab, "Machine Type" cannot be selected.
18) Click [Done] to complete the wizard.
The added machine now appears in OPC Explorer view, and if selected by a mouse click the details that
have just been entered appear in the Property View.
19) Right-Click "Machine Name" in explorer, and select "Edit <Machine Name>" on the pop-up menu. This
will start the wizard again so you can make changes to the machine configuration if desired.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 56/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 57/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
For the procedure after this, please refer to the section corresponding to the point type you create.
3.9.1 CNC System Information Point
3.9.2 Tool Offsets Point
3.9.3 Work Offsets Point
3.9.4 Program Data Point
3.9.5 Custom Macro Variable Point
3.9.6 Alarm Information Point
3.9.7 Axis Name Point
3.9.8 Position Information Point
3.9.9 PMC Data Point
3.9.10 PMC Alarm Point
3.9.11 Number of Machined Parts
3.9.12 P-CODE Variable Point
3.9.13 Operator Messages Point
3.9.14 CNC Status Point
NOTE
Even if points are defined as an array in the FANUC OPC server, it is not possible
to read from and write to the specified range by using IndexRange from the OPC
UA client.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 58/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
1) Start the Point Configuration Wizard. Click the [Next >>] button. The Path Selection tab appears in the
wizard.
2) Select [CNC Path 1] in the path for data point list box. Click the [Next >>] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 59/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 60/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Enter point name in the "Point Name" field. Enter point description in the "Point Description" field.
Click the [Done] button, the point should now appear in the OPC Explorer view.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 61/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 62/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 63/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 64/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
In case of Mc system of 30i/31i/32i-A/B (With Tool offset for Milling and Turning function option)
Offset Type Memory C(*1)
X Axis - Wear XW
X Axis - Geometry XG
Tool Length - Wear Z/LENGTH W
Tool Length - Geometry Z/LENGTH G
Cutter Radius -Wear NOSE R/RAD W
Cutter Radius - Geometry NOSE R/RAD G
Imaginary Tool Nose - Wear T
Imaginary Tool Nose - Geometry T
Y Axis - Wear YW
Y Axis - Geometry YG
Corner R - Wear CORNER R W
Corner R - Geometry CORNER R G
*1 Tool offset memory C is required.
In case of Tc system of 30i/31i/32i-A/B (With Tool offset for Milling and Turning function option)
Offset Type Memory C(*1)
X Axis - Wear XW
X Axis - Geometry XG
Z Axis - Wear Z/LENGTH W
Z Axis - Geometry Z/LENGTH G
Nose R - Wear NOSE R/RAD W
Nose R - Geometry NOSE R/RAD G
Imaginary Tool Nose - Wear T
Imaginary Tool Nose - Geometry T
Y Axis - Wear YW
Y Axis - Geometry YG
X Axis - 2nd Geometry Offset-Geometry X AXIS G 2ND GEOM
Z Axis - 2nd Geometry Offset-Geometry Z AXIS G 2ND GEOM
Y Axis - 2nd Geometry Offset-Geometry Y AXIS G 2ND GEOM
*1 Tool offset memory C is required.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 65/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 66/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Enter point name in the "Point Name" field. Enter point description in the "Point Description" field.
Click the [Done] button, the point should now appear in the OPC Explorer view.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 67/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 68/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 69/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 70/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Enter point name in the "Point Name" field. Enter point description in the "Point Description" field.
Click the [Done] button, the point should now appear in the OPC Explorer view.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 71/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
1) Start the Point Configuration Wizard. Click the [Next >>] button. The Path Selection tab appears in the
wizard.
2) Select [CNC Path 1] in the path for data point list box. Click the [Next >>] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 72/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 73/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Enter point name in the "Point Name" field. Enter point description in the "Point Description" field.
Click the [Done] button, the point should now appear in the OPC Explorer view.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 74/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Data Type
Custom Macro Local Variable (#1-#33)
Custom Macro Embedded Macro Variable (#200-#499)
Custom Macro Common Variable (#100-#199)
Custom Macro Common Variable (#500-#999)
Custom Macro Common Variable (#98000-#98499)
Custom Macro System Variable (#1000-)
Custom Macro System Variable (#10000-)
Custom Macro System Variable (#10000-)
1) Start the Point Configuration Wizard. Click the [Next >>] button. The Path Selection tab appears in the
wizard.
2) Select [CNC Path 1] in the path for data point list box. Click the [Next >>] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 75/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 76/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Enter point name in the "Point Name" field. Enter point description in the "Point Description" field.
Click the [Done] button, the point should now appear in the OPC Explorer view.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 77/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
In case of 30i/31i/32i/35i/0i-D/0i-F/Power Motion i-A. The number of significant digits is 12. (6008#0=0)
Range of Values(*1) Display of CNC(*2) Internal Retainable Range of CNC(*3)
0 < Values < + 0.00000000001 + UNDERFLOW 0 < Values <= + 10 -308
0 > Values > - 0.00000000001 - UNDERFLOW 0 > Values >= - 10 -308
Values > + 999999999999 + OVERFLOW 0 < Values <= + 10 308
Values < - 999999999999 - OVERFLOW 0 > Values >= - 10 308
NOTE
There was a case that the value read by the OPC client is displayed as an
exponent. It was fixed so that it will not be displayed as an exponent.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 78/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
1) Start the Point Configuration Wizard. Click the [Next >>] button. The Path Selection tab appears in the
wizard.
2) Select [CNC Path 1] in the path for data point list box. Click the [Next >>] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 79/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 80/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
When the CNC Type (Control Types) is 0i-B/C, 16i/18i/21i-A/B or PMi-D/H, and the language other than
English and Japanese is selected, alarm number only can be read even if Alarm Messages is selected as
Data Type.
If the number of Alarm Messages occurring in the CNC is fewer than the specified number of the array, the
empty string (length of the string is 0) is set in the place where the message is not read.
Click the [Next >>] button.
Enter point name in the "Point Name" field. Enter point description in the "Point Description" field.
Click the [Done] button, the point should now appear in the OPC Explorer view.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 81/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 82/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 83/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Enter point name in the "Point Name" field. Enter point description in the "Point Description" field.
Click the [Done] button, the point should now appear in the OPC Explorer view.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 84/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Data Type
Absolute Position
Relative Position
Machine Position
Distance to go Position
1) Start the Point Configuration Wizard. Click the [Next >>] button. The Path Selection tab appears in the
wizard.
2) Select [CNC Path 1] in the path for data point list box. Click the [Next >>] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 85/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 86/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Select the "Axis Number" and "Array Size". Click the [Next >>] button.
Enter point name in the "Point Name" field. Enter point description in the "Point Description" field.
Click the [Done] button, the point should now appear in the OPC Explorer view.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 87/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Data Type
PMC Bit
PMC Byte
PMC 2Byte
PMC 4Byte
1) Start the Point Configuration Wizard. Click the [Next >>] button. The Path Selection tab appears in the
wizard.
2) Select the PMC Path number in Path for Data Point list box. PMC Path number is listed by the format of
[PMC Path <PMC Path Number>]. Click the [Next >>] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 88/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 89/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 90/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Enter point name in the "Point Name" field. Enter point description in the "Point Description" field.
Click the [Done] button, the point should now appear in the OPC Explorer view.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 91/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
1) Start the Point Configuration Wizard. Click the [Next >>] button. The Path Selection tab appears in the
wizard.
2) Select the PMC Path number in Path for Data Point list box. PMC Path number is listed by the format of
[PMC Path <PMC Path Number>]. Click the [Next >>] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 92/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 93/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 94/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Enter point name in the "Point Name" field. Enter point description in the "Point Description" field.
Click the [Done] button, the point should now appear in the OPC Explorer view.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 95/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
1) Start the Point Configuration Wizard. Click the [Next >>] button. The Path Selection tab appears in the
wizard.
2) Select [CNC Path 1] in the path for data point list box. Click the [Next >>] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 96/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 97/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Enter point name in the "Point Name" field. Enter point description in the "Point Description" field.
Click the [Done] button, the point should now appear in the OPC Explorer view.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 98/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
In case of 30i / 31i / 32i / 35i / 0i-D /0i-F / Power Motion i-A
Data Type Access Type
P-CODE Control Variable (#8500-#8999) R
P-CODE Variable (#10000-#19999) R, W, RW
Extended P-CODE Variable (#20000-#89999)
1) Start the Point Configuration Wizard. Click the [Next >>] button. The Path Selection tab appears in the
wizard.
2) Select [CNC Path 1] in the path for data point list box.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 99/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 100/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 101/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Enter point name in the "Point Name" field. Enter point description in the "Point Description" field.
Click the [Done] button, the point should now appear in the OPC Explorer view.
For "The <null> value of CNC", "Effective range and display of variable", refer to the chapter of
"Custom Macro Variable Point".
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 102/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 103/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 104/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 105/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Enter point name in the "Point Name" field. Enter point description in the "Point Description" field.
Click the [Done] button, the point should now appear in the OPC Explorer view.
If the number of Operator Messages occurring in the CNC is fewer than the specified number of the array,
the empty string (length of the string is 0) is set in the place where the message is not read.
Example: Array size set by configurator is 6, CNC generates 1 External Operator message and 1 Macro
message occurs.
String[0] External Operator Message "OPR2000 EXT_MES1"
String[1] Macro Message "MCR0 ABC"
String[2] Empty String ""
String[3] Empty String ""
String[4] Empty String ""
String[5] Empty String ""
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 106/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
In the OPC Quick Client, it is displayed as follows.In the red frame ", , , ," means 4 empty strings.
NOTE
When the CNC Type (Control Types) is 0i-B/C, 16i/18i/21i-A/B or PMi-D/H, and
the language other than English and Japanese is selected, the message body will
be not output. And the maximum number of messages that can be acquired with
these models is five.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 107/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Data Type
CNC Status(Mode)
CNC Status(Operation)
CNC Status(Emergency)
1) Start the Point Configuration Wizard. Click the [Next >>] button. The Path Selection tab appears in the
wizard.
2) Select [CNC Path 1] in the path for data point list box. Click the [Next >>] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 108/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 109/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Enter point name in the "Point Name" field. Enter point description in the "Point Description" field.
Click the [Done] button, the point should now appear in the OPC Explorer view.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 110/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 111/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
[New Configuration]
Creates a new configuration file.
[Open Configuration]
Opens a previously created configuration file.
[Close Configuration]
Closes the open configuration file.
[Save Configuration]
Saves the open configuration file.
[Save As Configuration]
Saves the open configuration file with another name.
[Export…]
Exports the open configuration file.
[Recent Files]
Displays the most recently saved configuration file.
[Exit]
Exits the OPC Configurator.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 112/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
User account settings screen, click the [Tools] menu, click the drop-down menu [User Account Configuration].
[Delete]
Delete the selected user account.
"admin" user cannot be deleted.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 113/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
[Edit]
Change the selected user account name and password.
Click to open the Edit account screen.
[Add]
Add a new user account.
If the number of registered user accounts of 50, you cannot select this button.
Click to open the Add Account screen.
[Done]
Save the user account that is displayed.
Click to user account list screen is closed.
[Cancel]
To cancel all of the operation of the user account list screen, and close the screen.
[User Name]
Enter user account name.
Input possible character is up to 32 characters.
"Admin" name of the user cannot be changed.
Invalid user name is entered, error message is displayed.
Invalid user name
Registered user name
Characters use of disabled
Exceeds the maximum number of characters
[Password]
Enter user account password.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 114/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 115/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
4 OPC Server
This chapter explains the user interface of OPC Server. It displays the current operating status and trace
messages.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 116/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 117/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
1) Click [Trace] on the top menu. Select [Log File Settings] on the drop-down menu.
The Log File Settings window will open.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 118/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
4.4.4 Exit
This function exits the OPC Server.
Log Level
Log level can be specified.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 119/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 120/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 121/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
5 OPC UA support
This chapter describes the support of OPC UA of FANUC OPC server.
OPC Classic mode, can be equivalent operation and version 2.0.0 of FANUC OPC server.
OPC UA mode can be connected to a OPC client of the OPC UA standard in addition to the OPC client of the
OPC DA standard.
NOTE
OPC Classic mode, cannot be connected to the OPC UA client.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 122/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
1) Configuration settings screen of FANUC OPC Configurator, set the [OPC UA Mode] check box.
Please display method of the screen, see "3.7 configuration settings" on "Ⅲ. Setting".
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 123/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
NOTE
Windows XP cannot use this discovery feature.
Connection from the OPC UA client in Windows XP, please connect by specifying
the endpoint directly.
1) When you start the FANUC OPC server in UA mode, it will be issued a certificate of FANUC OPC server.
Certificate Folder : C:¥ProgramData¥FANUC¥OPCServer¥ PKI¥CA¥certs
File name of the issued certificate is "MyCertificate.der".
2) Issued FANUC OPC server of the certificate will also be created to reject folder of the certificate issued at
the same time as LDS.
Reject Folder : C:¥ProgramData¥OPC Foundation¥UA¥Discovery¥pki¥rejected
The name of the file that is created is created with the following rules.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 124/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Thumbprint of the
"MyCertificate.der" file is in the
file name
3) After that the file of reject folder of LDS of the certificate is a FANUC OPC server of the certificate is
confirmed, move it to the trust folder of LDS.
Trust Folder : C:¥ProgramData¥OPC Foundation¥UA¥Discovery¥pki¥trusted¥certs
4) Search for the FANUC OPC server from the OPC UA client.
1) Select the "opc.tcp-None-None" from the search was FANUC OPC server security mode.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 125/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
2) Select the "UserName" from the "User Identity" field, enter "admin" in the "User Name" field, enter
"admin" (is displayed ●●●●●) to the "Password" field.
3) [Validate Connection] button is connected to success When a green check mark appears, press.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 126/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
2) Select the "UserName" from the "User Identity" field, enter "admin" in the "User Name" field, enter
"admin" (is displayed ●●●●●) to the "Password" field. (No security and the same)
3) If you are using a Softing OPC UA Client, you will see the following screen and press the [Validate
Connection] button.
In this case, select the "Add Certifivate To Trusted Store", then press the OK button.
When you press the OK button, the trust folder of Softing OPC UA Client, FANUC OPC server of the
certificate is created.
Trust Folder : C:¥ProgramData¥Softing¥OpcClient¥pki¥trusted¥certs
Create File Name : FANUCOPCServer@ComputerName [Thumbprint number].der
Thumbprint number : Thumbprint number of FANUC OPC server's certificate
Example)
FANUCOPCServer@WIN-BB2CH2V6TER [DF11A43CD19F723026EF66F8A2C2C5FC9DB4526A].der
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 127/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
4) [Validate Connection] button red "X" mark appears, and connection failure.
NOTE
Connection failure in this case, is normal.
Since the OPC UA client certificate has not been authenticated to the OPC UA
server, and connection failure.
5) If the connection fails, to reject folder of FANUC OPC server, certificate of OPC UA client is created.
Reject Folder : C:¥ProgramData¥FANUC¥OPCServer¥PKI¥CA¥rejected
File name is the same as the naming convention of the file name of the 2) of "5.4.1 search of the OPC
server".
6) The OPC UA client's certificate in the reject folder of FANUC OPC server, move it to the trust folder of
FANUC OPC server.
Trust Folder : C:¥ProgramData¥FANUC¥OPCServer¥PKI¥CA¥certs
7) Again, it is a successful connection when you see a green check mark by pressing the [Validate
Connection] button.
NOTE
Same operation in other security mode.
SignAndEncrypt-Basic128Rsa15
Sign-Basic256
SignAndEncrypt-Basic256
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 128/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
OPC UA standards, at the time of connection of the OPC UA server and the OPC UA client, make sure both of
the certificate, has established a security on the communication by authentication.
In addition, LDS also be authenticated to verify the certificate of the OPC UA server, you have to notice the
existence of the OPC UA server to the OPC UA client.
①FANUC OPC server certificate, once, will be created in the reject folder of LDS.
②The certificate of the LDS reject folder, by moving to trust folder of LDS, to register the FANUC OPC
server.
LDS to that OPC UA server is registered, you can search the OPC UA server from the OPC UA client.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 129/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
①FANUC OPC server certificate, once, will be created in the reject folder of the OPC UA client.
②A certificate of reject folder of the OPC UA client, by moving to trust folder of the OPC UA client and
allow the connection of the FANUC OPC server.
"Softing OPC UA Client" is a movement from the reject folder to trust folder, by selected on the
confirmation screen to the user, have been moved.
NOTE
How to move the certificate of the OPC UA client is dependent on the
specifications of the OPC UA client to use.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 130/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
①OPC UA client certificates, once, will be created in the reject folder of the OPC UA server.
②A certificate of reject folder of the OPC UA server, by moving to trust folder of the OPC UA server,
allows the connection with the OPC UA client.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 131/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Screen Description
[Current Mode] : Displays the current operating status of the FANUC OPC server.
"Application" "Service" "Service Stopped" is displayed.
[Operation Mode] : It is a radio button to select the mode of operation of the FANUC OPC server.
[Service Restart] : This button is used to when to restart the "FANUC OPC server" in the service mode.
[Switch] : This button to switch to the mode selected a "Operating Mode".
[End] : Exit the "FANUC OPC service tool".
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 132/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
When switching to the Windows service is complete, the "current mode" display will change to "service".
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 133/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
NOTE
Method of connecting also client running in service mode is the same as the
application mode.
However, the Connection to the OPC Classic client requires DCOM setting.
See [6.2 Connection to the OPC Classic clients]
NOTE
Even if the "Service Stopped" to the current mode is displayed, when the restart
operation of the service mode, you might be able to restart the service.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 134/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 135/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
7 DCOM Setting
This chapter describes DCOM summary, for the DCOM method of setting the server PC and the client PC.
If you want to connect in OPC Classic clients from other personal computer to the server of OPC Classic mode
requires DCOM setting.
This setting method in the case of server / client PC is "Windows 7 Professional 32bit OS".
7.1 Summary
The DCOM, a Microsoft's technology for communication between software components on a computer which is
distributed on the network (distributed object technology).
Another client PC and server PC (FANUC OPC server) (OPC Quick Client) will communicate with Ethernet
through DCOM.
Server PC Client PC
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 136/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 137/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
4) "Program:" Select the "OPC Quick Client" from the list, and click the [Add] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 138/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
5) "Allowed programs and features:" the has been added to the list "OPC Quick Client" is set as follows, and
then click the [OK] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 139/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
7) Click the "Inbound Rules", then click on the "New Rules ...".
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 140/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 141/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
13) Is an exception settings the completion of the Windows firewall or more. Close the open window.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 142/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
1) Enter the Start menu "Search programs and files" in the text box "dcomcnfg", and then click the
"dcomcnfg.exe" of search results.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 143/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
2) “Component Services", "computer", right-click on "My Computer", and then click "Properties" from the
pop-up menu.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 144/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
4) "COM security" Click on the tab, and then click [Edit Limits...] button of "Access permissions".
5) "Group or user names:" After selecting from the list "ANONYMOUS LOGON", "Permissions for
ANONYMOUS LOGON " the set as follows, and then click the [OK] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 145/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 146/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
8) "Enter the object names to select(examples):" to set the following, and then click the [OK] button.
"Enter the object names to select(examples):" To do this, enter the "Everyone".
9) "Group or user names:" After selecting the "Everyone" from the list, the "Permissions for Everyone" set as
follows, and then click the [OK] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 147/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
11) If the following message dialog box appears, click Yes (Y)] button.
If the dialog box does not appear, go to the next step.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 148/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
1) Open the [Control Panel], click the [Network and Sharing Center].
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 149/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
4) This enabled the completion of the network search / file sharing settings above. Close the open window.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 150/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 151/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 152/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
4) "Program:" Select the "FANUC OPC Server" from the list, and click the [Add] button.
5) "Allowed programs and features:" the has been added to the list "FANUC OPC Server" is set as follows,
and then click the [OK] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 153/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 154/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
9) Open the: "C:¥Windows¥System32" folder, after selecting the "OpcEnum" file, and then click [Open]
button.
Extension is displayed is "OpcEnum.exe" file.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 155/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
10) "Program:" Select the "OPC Server Enumerator 1.10" from the list, and click the [Add] button.
11) "Allowed programs and features:" the has been added to the list " OPC Server Enumerator 1.10" is set as
follows, and then click the [OK] button.
12) Is an exception settings the completion of the Windows firewall or more. Close the open window.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 156/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
1) Enter the Start menu "Search programs and files" in the text box "dcomcnfg", and then click the
"dcomcnfg.exe" of search results.
2) “Component Services", "computer", right-click on "My Computer", and then click "Properties" from the
pop-up menu.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 157/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
4) "COM security" Click on the tab, and then click [Edit Limits...] button of "Access permissions".
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 158/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
5) "Group or user names:" After selecting from the list "ANONYMOUS LOGON", "Permissions for
ANONYMOUS LOGON " the set as follows, and then click the [OK] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 159/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
8) "Enter the object names to select(examples):" to set the following, and then click the [OK] button.
"Enter the object names to select(examples):" To do this, enter the "Everyone".
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 160/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
9) "Group or user names:" After selecting the "Everyone" from the list, the "Permissions for Everyone" set as
follows, and then click the [OK] button.
10) Click the [Edit Limits...] button of "Launch and Activation Permissions".
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 161/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
11) "Group or user names:" After selecting from the list "Everyone", "Permissions for Everyone " the set as
follows, and then click the [OK] button.
12) Click the [Edit Default...] button of "Launch and Activation Permissions".
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 162/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
14) "Enter the object names to select(examples):" to set the following, and then click the [OK] button.
"Enter the object names to select(examples):" To do this, enter the "Everyone".
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 163/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
15) "Group or user names:" After selecting the "Everyone" from the list, the "Permissions for Everyone" set as
follows, and then click the [OK] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 164/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
17) If the following message dialog box appears, click Yes (Y)] button.
If the dialog box does not appear, go to the next step.
18) After selecting the “Component Services", "computer",” My Computer”, “DCOM Config”,right-click on
"OpcEnum" icon from the central area, and then click "Properties" from the pop-up menu.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 165/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
19) Click the "Security" tab, set the following, and then click the [OK] button.
20) After selecting the "Component Services", "computer","My Computer", "DCOM Config",right-click on
"FANUC OPC Server" icon from the central area, and then click "Properties" from the pop-up menu.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 166/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC
7169FgFxY1eFY7tj+YSgSn6b+jyVDe5JffSMJBfPo6s6+/VEC+2wd68VWEg==
21) Click the "Security" tab, set the following, and then click the [OK] button.
22) Click the "Identity" tab, set the following, and then click the [OK] button.
Title
FANUC OPC Server
Operator’s Manual
05 2020.09.30 R.Imada The security function of FOCAS2 added. T.Hosaka
04 2018.06.21 S.Matsukura Data type added.
03 2017.12.25 T.Hosaka OPC UA support
Draw A-40622-00001EN
02 2016.01.13 T.Hosaka Old CNC support and data type added.
Ed. Date Design Description FANUC CORPORATION Sheet. 167/167
Date 2015.09.25 Desig. T.Hosaka Check Apprv. K.Murata
© MyFANUC 6C796DB6F4A7460FAD4F42CFCC4A5FFC