0% found this document useful (0 votes)
55 views2 pages

5 TDS Bostik-Portugal-P330-English

The P330 Manual Multipurpose Polyurethane Foam is a single-component, B3 foam designed for various construction applications, offering excellent thermal and acoustic insulation properties. It is suitable for use in assembling door and window trim, with a curing time of 100-120 minutes and a density of 25-35 kg/m3. The foam should be applied in well-ventilated areas and is not recommended for certain plastics or continuous water exposure.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
55 views2 pages

5 TDS Bostik-Portugal-P330-English

The P330 Manual Multipurpose Polyurethane Foam is a single-component, B3 foam designed for various construction applications, offering excellent thermal and acoustic insulation properties. It is suitable for use in assembling door and window trim, with a curing time of 100-120 minutes and a density of 25-35 kg/m3. The foam should be applied in well-ventilated areas and is not recommended for certain plastics or continuous water exposure.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

P330

MANUAL MULTIPURPOSE POLYURETHANE FOAM

DATASHEET | LAST REV.: 10/04/2023 | Page 1 of 2

BENEFITS

• B3 polyurethane foam for manual application


• Excellent thermal properties
• Excellent acoustic properties

DESCRIPTION TECHNICAL CHARACTERISTICS


P330 MANUAL MULTIPURPOSE POLYURETHANE FOAM Description Results
is an expandable, single-component, manually applied
Application temperature +10 C to +35 C
B3 foam, with multiple applications in the construction
and rehabilitation of buildings. It has good adhesion to Base Polyurethane
most construction materials. Excellent thermal and Closed cell structure ±70%
acoustic insulation properties. Allows you to obtain a
lasting seal. Allows painting after curing. Cure 100-120 minutes

You can cut yourself after 30-50 min. (EN 17333-3)

APPLICATIONS Fire resistance class B3

Polyurethane foam for assembling door and window Density 25-35 kg/m3
trim, filling hollow areas and piping and cable crossing
Dimensional stability - 5% < DS < 0% (EN 17333-2)
areas. It has excellent adhesion on cement, brick, stone,
plasterboard, wood, metal, Styrofoam, rigid Skin formation 8-12 min. (EN 17333-3)
polyurethane and uPVC panels. Temperature resistance - 40 C to +90 C

Thermal conductivity 30-35 mW/m∙K


LIMITATIONS Typical values.
Not suitable for PE, PP, PC, PMMA, PTFE, flexible plastics,
neoprene and bituminous surfaces.
Not recommended for continuous exposure to water. SURFACE PREPARATION AND FINISHING
Not suitable for filling cavities in places with reduced Surfaces must be clean, free from dust and properly
ventilation or low humidity. degreased. Before applying, it is important to slightly
moisten the surface in order to improve the adhesion
and cellular structure of the foam.
TECHNICAL SHEET P 330 MULTIPURPOSE POLYURETHANE FOAM MANUAL | LAST REV.: 10/04/2023 | Page 2 of 2

APPLICATION INSTRUCTIONS EXPIRY AND STORAGE


Temperature from the packaging: + 5°C to + 30°C Shelf life of 18 months after the date of manufacture, in
(recommended +15°C to +25°C). Application the original unopened packaging, stored in a dry place,
temperature (applies to room and surface at a temperature between +5˚C and +25˚C, protected
temperatures): +10°C to +35°C (recommended +15°C to+ from frost. Packaging must be stored in a vertical
25°C). On days with low temperatures, ensure that the position, with the valve pointing upwards.
packaging is at the same temperature as the room/
compartment where it will be applied (minimum +5°C).
Shake the packaging vigorously (20 to 30 times) before
PRESENTATION
starting to apply. Screw the cannula firmly onto the
packaging valve and proceed with application, with the 700ml aerosol. Boxes with 12 units.
valve facing downwards, pressing the adapter. Only fill
50% of the cavities. The foam will expand to fill the PRECAUTIONS
remainder. When fixing window frames, suitable spacers
Consult the safety data sheet before using the product.
must be used until the foam has completely cured
(approx. 24 hours). During application, wear eye/face
protection gloves and suitable protective clothing. CERTIFICATIONS
Protect adjacent areas, including the floor and furniture, Emicode EC1 Plus
with paper or plastic film. Apply to joints less than 40mm
A+ French VOC Regulation
wide and 50mm deep. Joints with greater width must be
filled in layers at intervals of 15-30 minutes. Pre-moisten
each layer with water, using a spray bottle. Use in well- LEGAL NOTICE

ventilated places. Store packages in a vertical position, This technical sheet replaces all previous versions.
with the valve pointing upwards, at a temperature BOSTIK guarantees that the product complies with its
between +5°C and +25°C. Pressurized packaging! Keep specifications during its validity period. The information
away from sunlight. Do not expose to temperatures contained in this document and in all our publications is
above +50°C. Do not puncture or burn, even after use. based on our knowledge and experience. BOSTIK cannot
Extremely flammable aerosol. Contains flammable be held responsible for any errors, inaccuracies or
propellants. Do not spray on an open flame or other editorial errors that result from technological changes or
ignition source. Keep away from heat, hot surfaces, R&D between the date of issue of this document and the
sparks, open flames and other sources of ignition. Do date the product was purchased. BOSTIK reserves the
not smoke. After complete curing, cut off the excess with right to make changes to product formulations. Before
a knife or x-ato. For more information, see our website applying the product, the user must familiarize
or contact our local sales representative. themselves with the information presented in this
document and/or related documents. The product must
be tested to assess its suitability for the intended
PAINTING
application and purposes. The method of application,
Accepts painting or other types of coating (sealant, paint, storage and transport conditions are beyond our direct
plaster...) after complete curing. Previous adhesion and control and are not our responsibility. All deliveries are
compatibility tests are always recommended. subject to our general sales conditions, available upon
request. The information mentioned in this document is
merely indicative.
CLEANING
Uncured foam and application tools should be cleaned
with Bostik P100 FOAM'N'CLEAN POWER. Once cured, it
can only be removed mechanically. Hands should be
cleaned with cleaning wipes. Avoid direct contact with
the skin. In case of accidental contact, clean immediately
with Bostik P100 FOAM'N'CLEAN POWER or cleaning
wipes.

Bostik Benelux BV BOSTIK HOTLINE


Denariusstraat 11
4903 RC Oosterhout Smart help +31 (0)162 491 000
Phone: +31 (0)162 491 000
www.bostik.com

All advice, recommendations, figures and safety regulations provided are based on careful investigations, as well as the current state of our experience and are without obligation. Although the
documentation has been compiled with the greatest care, we do not accept any liability for inaccuracies, mistakes, typesetting or printing errors. We reserve the right to modify the respective product if
we deem it necessary. Since the design, the quality of the substrate and the processing conditions are beyond our assessment, no liability can be accepted for work performed on the basis of this
documentation. We therefore advise you to carry out practical tests on site yourself. Our general Terms and Conditions of Sale and Delivery apply to all our sales and deliveries.

You might also like