The document outlines the specifications and requirements for equipping a hotel in Baghdad with air conditioning systems, detailing the building's layout, materials, and dimensions. It includes information on the cooling load calculations based on indoor and outdoor design conditions, as well as the thermal properties of walls, partitions, and roofs. Additionally, it lists the contents and equipment for each room and hall within the hotel.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
24 views35 pages

Air Conditioning Systems3

The document outlines the specifications and requirements for equipping a hotel in Baghdad with air conditioning systems, detailing the building's layout, materials, and dimensions. It includes information on the cooling load calculations based on indoor and outdoor design conditions, as well as the thermal properties of walls, partitions, and roofs. Additionally, it lists the contents and equipment for each room and hall within the hotel.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 35
mi Bal) 1 = Ministry of Higher Education and Scientific Research femal at] Dt) ll iia La ls Date a als ld | The Fourth stage 9 | oe yt ES eT yy Seep ty Ve ye Oy). "ms Nie == ea: A Yt a g jlo eile pSoll ae SS Bee ala § Brees emetic) De LE PY.) Or] Feet) eee) eet) oy Introduction: On Sunday, 6/10/2024, we received the (hotel) the building by the employer to equip the hotel with fully air conditioning systems. Location of the hotel in Baghdad The hotel consists of 10 rooms, 4 men hall and 9 toilets 1g, 2 family hallls, 2 hall,, 4 kitchens The building from the north Direction and the south Direction overlooks a 24-meter-wide street. The north Direction, the south Direction and the east Direction are exposed to sunlight. But the west Direction trend is conditioned. The height of all the walls of the building is 3 meters. The outer wall consists of Common brick,Cement plaster and Plaster or gypsum. And the inner wall (Partitions) consists of Plaster or gypsum,Common brick and Plaster or gypsum. And the roof consists of Plaster or gypsum,Concrete Tile,Sand,High density Concrete,Asphalt Roll Roofing and Expanded polyurethane. ‘Space of Door 2 height, 1 width Space of windows . Bedrooms 1.5 Height, 1.6 Width . Man hall Sitting 3 1.5 Height, 1.5 Width . Man hall Sitting 2 1.5 Height,1.2 Width |. Man hall Sitting 1 and 4 1.5 Height, 1.6 Width . Hall 1 1.5 Height,1.2 Width . Hall 2 1.5 Height,1 Width . Family hall 1 1.5 Height,1.15 Width . Family hall 2 PNYOTEENS The air conditioning and cooling system will be installed completely and we will show the method of installation in detail... And the work will be done in weather conditions Outdoor 45 C’DBT and 15 % RH, Indoor 25 C’DBT and 50% RH. Figure (1)The shape of the windows design Figure (2)The shape of the door design ‘bedroom 10 | ‘* The contents of the hotel for each room No. | Application No.people Apps Light 1 | Bedroom 1 2 Tv,Cabinet 6 2 | Bedroom 2 2 Tv,Cabinet 5 3 | Bedroom 3 2 ‘Tv,Cabinet 5 4 | Bedroom 4 2 Tv,Cabinet 5 5 | Bedroom 5 2 Tv,Cabinet 5 6 | Bedroom 6 2 Tv,Cabinet 6 7 | Bedroom 7 2 Tv,Cabinet 5 8 | Bedroom 8 2 Tv,Cabinet 5 9 | Bedroom 9 2 Tv,Cabinet 5 10 | Bedroom 10 2 Tv,Cabinet 5 11 | Halt 2 Hot plate ,Tv 4 12 | Hall2 2 Hot plate ,Tv 4 13. | Family hall 4 is Coffee brewer 6 14, | Family hall 2 3 Coffee brewer 6 15. | Man hall sitting 1 4 Food warmer 6 16 | Man hall sitting 2 4 Food warmer 5 17 | Man hall sitting 3 4 Food warmer 6 18 | Man hall sitting 4 4 Food warmer 5 19. | Kitchen 1 — Blander ,oven 4 20 | Kitchen 2 — Blander ,oven 4 24 | Kitchen 3 — Blander ,oven 4 22 | Kitchen 4 — Blander ,oven 4 23 | Toilet 1 — —_ 1 24 | Toilet 2 — a 1 25 | Toilet 3 — 1 Toilet 4 Toilet 6 Toilet 7 Toilet 8 Toilet 9 Overall heat transfer coefficient, the equivalent temperature difference and weight of the wall, partition and roof : *_ Outside Wall : Description R w Outside surface resistance 0.059 0 ‘Common brick 0.279 390.40 Inside surface resistance 0.121 0 Cement plaster 0.05 105.6 Plaster or gypsum 0.026 30.74 © U=t/cR U=1/(Ro#R1+R2+R3+R44Rin) Ust/ (0.059+0.05+0.279+0.05+0.026+0.121) U= 1.709 Wim?.k [146.65 5 si3.86 g i FE : paar = [p75 75 io > _fraas6 Nos. en £ femme Ti his * [oe Toten =P 55 rt > _fito ye _feme =z 258 os > [esa fae [Latent 2 00 os > fio Fl? = Ww F tighe = [6 50 25 _ srs Nos Ww Fe 5 [ecmoror = = = TOA Wind ic=77 los laa £ |" |oaDoor é 0.83 SeOLNs ef =[_2 Nos Jes E Sis z vox =[ ssetvs| fest [+ | Sunel- | reaouivs F vox a na Joast = fia 280 | ~ [20 Eine = fre z - ea ne 2 fraes [x fio fess le = P5577 F 5 = [210 E I = [25877 eo > [7677 Is = [2557.7 {pr [2869.6 a = [210 “8.1 > fisrs o = [2869.6 far = [3061.5 [Cooling toad Tndoor Design condition [Gutdoor design condition [Month “August (8) [346.8 Twindow en eo c [oo —_atene 70 Py fe pete [258 [so latent 00 el? . ge si25 lo [tec moror ee TOA Wind ic=77 los eat £ |" |lOADoor =|6 jo.93 a 5.56 EPpy 2 Nos fx [2.5 E Silvis e Ox B58 live] [231 [+ 5 Liv’s|= 12.89 Lis F ay a foasie = fr289 | [20 F Joan i Joarn fees [x fo a = [1997.33 F is _frus = 210 F fa [anit = [1997.33 a0 F hs [rs 1997.33 {fra E fo fru a “p81 F fo __|oree = [2909.23 “fist 9 F [Ousicordeugncondnion [45 CBT] ‘S/ window Twindow Twindow Twindow ‘SWall Wall Dwall DWall Roof Floor Partitions 558 Ls Sis 12.44 Lvs 301.04 17At 42 [283.63 [2080.54 [210 [2080.54 [2290.54 2080.54 [2381 58 a 19259 2381.58 [2574.17 [Cooling Load Tndoor Design condition [Sucoor design condifon [Month August (6) ‘Solar Gainwinows rao [Joana re iF fr | S7window |= [85 laa in a68 Twindow J =| Twindow [=| e Twindow =| 5 Trancninson windows : Swat =fr708 Poe ToS . Wall ? Twat z Tall Al Roof a5 oz | [2r6 320.56 Floor : 5 —[Partiions Fo nm foo [larene 0 Fy Co 258. [a> —_[latene 00 =|? = tiene si25 a oo ze TOA Wind 7-86 g OA Door 5.58 Livs ae |v Sis 2 [por Sseungh reefs [Sune — | aes fsa Joast 307.04 fav Jot Pat fue oar 263.63 fs _|asi fs frum hs fae fs fis hs frun fp __|orw [Cooling Load a Pasion |e coer] rer] [Month -Acquste)———Poakimes pm (omy = ‘S/ window Twindow Twindow Twindow 300% pute 30014 ‘s}eeM ‘SWall 5-708 Wall Dwall DWall Roof 1455 Floor Partitions 1.745 > [12.44 Livs 301.04 17.41 2 = [283.63 RSH [2093.65 F RL [210 RTH 2093.65 *2t0 a frst [2093.65 =|s0r.04 [2394.69 fro 210 sfa7at 192.59 lor [2394.69 3[192.59 2587.28 [Cooling Load Building:Hotel Tndoor Design condition [Outdoor design condition 45 CDE) Month :August (8) Peak time: 3 pm. N J window Twindow T window Twindow ‘Solar and Transmision Gaim 0041 PUE JOLY ‘TEEN 5 [x Ate NwWall = 99 a E EnWall = ~ fos fet Tall wall 0 Roof Floor 5.58 Livs Sis 12.89 Livs ——— 45 CDBT| Peak time: 3 pm [City:Baghdad ‘Solar Gain windows Twindow Twindow Twindow Mall Dall Wall Roof Floor Partitions © [oe [tatene 2 ss [fi [iio § [fens 2 258 05 [258 [s5 [Latent 2 100 05 00 E - Ww F . Ligne 5 so [fesse Nos. Ww F [5 __|Blec- motor 7 = | [OAWing lo=7.7 ~]o3 eat g OA Door 6 0.93 558 Lis ep 2 Nos|* [25 Bits 2 vox sss fest [+ | stivs|- | 1289 Livs : F vou a fia [oaste han “fiz89 | [20 Eig) ub [oan 000 % fuc_foarn 2 _frzes_[xfis f= [esi = [762.87 - is eu is [arn 1762.81 “210 = [r992.67 is [rst 1782.81 +e l2094.77 fo [run 210 +fiat 191.9) len [2286.61 Twindow Twindow 3904 pu 20044 ‘EEN, Solar Gain windows F 17 {00 pue B00 STEM, 5 [Partitions [or [sensi 2 [sb |eatene =f2 55 i > __|[n10 Pe [s_femiie 2 [258 os [258 a> ftatene 2 100. 05 = [i00 e|7 Ww F = iahe 5 50 125 se Now Ww F ip [ew motor [= 7 =| ,, [oAwing c= 62 os 786 g TOA Door |= |b = 0.93 558 & fe 2 Noss [25 F Sis B vox =[ Ssetivs|s fest f+ Slivs|- | 12.44 Lis F von a loxst hn 7 fieaa_| [0 = |s0r.04 foaLn = Prat a OO 2 fk fraaa_[x fro 283.63 fs [asi 773.38 sau fat0 fa [ane = fi773.36 a0) > 1983.38 hs [isn 173.38 =fs01.08 = |e0ra.42 is fru 210 *farat > [rs258 fo [orn = [2074.42 = |192.59 = _ 2267.01 [Cooling Load (Building: Hotel [Room nameBedroomi0__ [Room No.10 Indoor Design condition 25 DBT| ~cwai RH _50%| [Outdoor design condition 45C DBT Wei RH _15%| [Month -August (8) Peaktime:3pm___|CityBaghdad oo Solar Gat windows feq_[@ [Sonn y F | Niwindow [= [a1 laa _| [ur 167.28 Twindow 5 a Twindow 2 Twindow 7 a e Transmison windows F iene ik aT sae 2 20 56.6. = |6.42 ~ fea [feo = [a08.16 ‘Solar ad Trannason Cal 4 [Wim I ATe i Nwall__| = [1.709 “72 [*|es = __[t09.57 £ Wall = ? Wall = % E g Wall = eF Roof = [455 Tfia_[7 fete [348.85 g Floor = = = 5 [Partitions = [745 as a = [e537 Nos. ean ||P ike =e 75 i = |i50 * |o =[2 mc Tt 140. ra =e 258 los a fsb [latent =f2 100 | fos = foo =I? P Ww F * ight =|5 50 “125 12.5 Nos. Ww F jp [Flee motor [= z =| ,, [OAwing |= |tc=62 03 = [186 g TOA Door = 0.93 558 Lis a a id =[__2 Nos) [25 = Sits 2 vou =[_ssauvs jest_fe |S uivs| 12.44 Livs iF vou a ina JOastt = fae i244 _[~ [20 = [301.04 fab foatn = foe 7 F741 ine oar = |e i244 [x fis > [283.63 > [ast = [1897.47 fs [Run = 210 hy [arn = [1897.47 “210 2107.47 is [rs 1897.47 ~]s0r.08 = [2198.51 ae lato spat a fe [orn = [2198.51 +[192.59 = [2391.1 [5241.45 [3701.65 OA Wind OA Door 35.56 LVS i 75 Ws oR 14.67 Lis [Cootingtoad ___[Building:Hotel_]Room name: Family Hall2 [Room No.14_ 14.67 Lis [Cooling toad ___[Building:Hotel_[Feomnane: Men rat sting_[Room No.15 [ indoor Desigacondition [25C DST] wa 5.58 Lis TO lvs 17.89 Lis 45coet{ sc warf RH 15%] [Peak time:3pm__[CityBaghdad fae iF hz 1429.02 Twindow {7004 pwe s0044 STEM, arent Sensible ight lec. motor OA Wind TOA Door : 5.58 Vv 10 lvs vox joasi loan joar EE Gs Sensible [Latent Light Elec: motor OA Wind OA Door 558 LS 10 Ws vox 17.89 Lvs loa i i zB Hs [I i “€ E 2.31 558 Lis HO lis 17.89 Lis Indoor Design condition Outdoor design condition Month = August () Building Cooling Load ROOM LOAD 44900.79 8441.2 City: Baghdad 53341.99 20 44900.79+8441.2 VENTILATION TOND a VOA - 341.97 Lits ; VOR a 2 an | x | 341.97 20 8275.674 3 3000 x -478.758 Ea] 1.2 x | 341.97 19 796.916 EFVECTIVE ROOM TOAD 35 0.15 : w Fi w z 26 : 8275.674 x] 015 44900.79 = | 46142.141 7 -478.758 x] 0.15 8441.2 = | 8369.3863 28 796.916 x} 0.15 53341.99 = [54511527 7 _ JERSH+ERTH= Adp= 8.9 46 142.1411+54511.5274= 0.8464 SUPPLY AIR 3 61421477) ERSH 44900.79 8441.2 941.97x45 + (2786,55-341.97)x25 + 2786.55 8275.674 -478.758 53176.464 7962.442 36 53176.464 7962.442 61138.906 7 19.9 (WBT) 8 11 (WBT) Building Load= Bedroom 1 311.9 18.1 293.8 12.89 0.85 Bedroom 2 311.9 18.1 293.8 12.89 0.70 Bedroom 3 301.04 “17.41 283.63 12.44 0.72 Bedroom 4 301.04 “17.41 283.63 12.44 0.68 Bedroom 5 301.04 “17.41 283.63 12.44 0.727 Bedroom 6 311.9 18.1 293.8 12.89 0.76 Bedroom 7 311.9 18.1 293.8 12.89 0.64 Bedroom 8 301.04 17.41 283.63 12.44 0.68 Bedroom 9 301.04 17.41 283.63 12.44 0.63 Bedroom 10 301.04 “17.41 283.63 12.44 0.67 Hall 1 160.20 9.27 150.93 6.62 1.51 Hall 2 160.20 9.27 150.93 6.62 1.50 Family hall 1 355.01 -20.54 334.47 14.67 1.59 Family hall 2 355.01 -20.54 334.47 14.67 1.19 Men hall 1 432.93 -25.04 407.89 17.89 0.75 Men hall 2 416.24 24.08 392.16 17.2 0.98 Men hall 3 432.93 -25.04 407.89 17.89 1.14 Men hall 4 432.93 -25.04 407.89 17.89 0.73 Total 8275.674 478.758 7796.916 341.97 17.169 Building load = 17.169 ton = 17.17 ton 2 3.20 be a -® 220 e a R 4 320 , | a ra 410 320 ) 4.00 097 al 3.00 8 a T 3.20 2.40 8 a | _ i Sm FF é t aad 120 : 2 [ e “ ——— : I ae a 7 = | = 3.00 — 2.10 J silt : A 3 it 378 /\he 4.00 0.93) 240 7 i z R1 0.04950 137.934 R2 0.04077 113.607 R3 0.04193 116.840 R4 0.03960 110.347 RS 0.04234 117.982 R6 0.04426 123.332 R7 0.03727 103.854 R8 0.03960 110.347 RO 0.03669 102.238 R10 0.03902 108.731 Hall 1 0.08794 245.049 Hall 2 0.08736 243.433 Family Hall 1 0.09260 258.034 Family Hall 2 0.06931 193.135 Men Hall 1 0.04368 121.716 Men Hall 2 0.05707 159.028 Men Hall 3 0.06639 185 Men hall 4 0.04251 118.456 Total 0.95784 2669.063 Supply and Return Diffuser: 1. Bedrooms + Supply Diffusers: Use ceiling diffusers or round ceiling diffusers to provide even, quiet airflow. Bedrooms should have comfortable, draft-free air distribution to ensure a peaceful sleeping environment. + Return Diffusers: Eggcrate grilles or louvered grilles can work well for return air. Install them near the door or on the ceiling opposite the supply diffuser to maintain balanced airflow. 2. Halls and Corridors + Supply Diffusers: Consider linear slot diffusers along the length of the corridors for even airflow distribution. They provide a streamlined appearance that blends well with corridor designs and are ideal for long, narrow spaces. [ + Return Diffusers: Eggcrate grilles placed at the end of each hall can efficiently pull return air without creating drafts. 3. Sitting Rooms and Family Hall Areas + Supply Diffusers: For larger areas like family halls and sitting rooms, square or round ceiling diffusers are suitable as they provide uniform air distribution. If the ceiling design allows, linear slot diffusers could also be used for a modern look. + Return Diffusers: Place eggcrate grilles or perforated return diffusers on the ceiling or walls near the exit points to avoid drafts and ensure proper return airflow. + Supply Diffusers: Use perforated ceiling diffusers for quiet and uniform airflow distribution, creating a comfortable atmosphere in this social area. + Return Diffusers: Eggcrate grilles are a good choice here, especially if they are positioned on the opposite wall or ceiling area to the supply diffusers to promote balanced airflow.

You might also like