D4SL-N / D4SL-NSK10-LK@
World's smallest Class 6-contact Guard Lock
Safety-door Switch
<Guard Lock Safety-door Switch D4SL-N>
• Wiring time is reduced with two types of wiring Guard Lock Safety-door Switch
methods capable of one-touch attachment and
removal.
• A wide variety of built-in switches can be used for
various devices.
(4-, 5-, and 6-contact models are available)
• Key holding force of 1,300 N.
• It is possible to change the key insertion point
without detaching the head.
• Significantly reduced solenoid current contributes
to the reduction of power supply cost. Slide Key
Terminal
Block Type Connector Type
<Slide Key D4SL-NSK10-LK@>
• Lockout Key to prevent workers from becoming
trapped inside the hazardous area.
• The vertical D4SL Guard Lock Safety-door Switch
can be easily mounted on 40 × 40 mm aluminum
frames.
• The plastic material makes the Slide Key suitable
for lightweight doors.
Be sure to read the “Safety Precautions”
on page 22.
1
D4SL-N / D4SL-NSK10-LK@
Model Number Structure
Model Number Legend
Switch (Standard type)
D4SL-N @@@@-@
(1) (2) (3) (4)
@@
(5) (6) (7)
Operation key
D4SL-N K@@
(1) (2)
2
D4SL-N / D4SL-NSK10-LK@
Ordering Information
List of Models
Contact configuration Conduit
Release Wiring Solenoid voltage/ Lock and
(door open/closed detection switch size Model
Key Type method Indicator release type
and lock monitor switch contacts) (See Note.)
6-contact Model G1/2 D4SL-N2@FA-DN
Insert the built-in switch (N, P, Q or R) 1/2-14NPT D4SL-N3@FA-DN
into the blank @. M20 D4SL-N4@FA-DN
24VDC
(Orange) G1/2 D4SL-N2@FA-DN
5-contact Model
Connector Insert the built-in switch (E, F, G or H) 1/2-14NPT D4SL-N3@FA-DN
into the blank @. M20 D4SL-N4@FA-DN
3
D4SL-N / D4SL-NSK10-LK@
Contact configuration
Release Wiring Solenoid voltage/ Lock and Conduit size
(door open/closed detection switch Model
Key Type method Indicator release type (See Note.)
and lock monitor switch contacts)
4
D4SL-N / D4SL-NSK10-LK@
Operation Keys
Type Model
Horizontal mounting
(Short) D4SL-NK1S
Horizontal mounting
D4SL-NK1G
(Cushion rubber)
Vertical mounting
D4SL-NK2G
(Cushion rubber)
Adjustable
D4SL-NK3
(Horizontal)
Connector Cables
Cable length Model
1m D4SL-CN1
3m D4SL-CN3
5m D4SL-CN5
5
D4SL-N / D4SL-NSK10-LK@
Slide Key
Applicable
Type Specifications Contents Model
Door Switch
Note: 1. The Door Switch is not included. Select the Door Switch depending on the necessary number of contacts and the conduit size.
The contents are provided as a total set, individual contents cannot be ordered separately.
2. Perform risk assessment for the equipment in question, configure relay units and other safety circuits, and use properly.
* The inner lever for D4GL-SK10/D4SL-NSK10 that can not be used for other products and applications.
+ =
D4SL-NSK10-LK D4SL-N
D4SL-NSK10-LKH
+ =
D4SL-NSK10-LKH D4SL-N
6
D4SL-N / D4SL-NSK10-LK@
Features
The lockout key prevents workers from becoming trapped without using a padlock.
Note: Using LEDs of D4SL-N enables confirming whether the door is open or closed and locked or unlocked.
Close door
Locked (power not supplied to
solenoid) The slide handle is closed.
CAUTION
Lockout key Guard Lock Safety-door
Switch will not be unlocked
with Lockout Key.
Lockout Key may be damaged
by operating Lockout Key
when the door is closed.
Always carry lockout key
when entering the Hazardous
area.
Close door
No. 7467139-3A
Left door
Lockout Key Door Opening to the Left.
The slide handle can be pulled. Do not turn the key as in the figure above if the
slide handle is closed.
When the slide handle is open, the The slide handle is secured at the position If the lockout key is not mounted, the
lockout key can be pulled regardless of shown in the figure. slide handle will not move and the
whether power is being supplied to the A worker holding the lockout key will not be door will not close.
solenoid or not. trapped locked inside the hazardous area by
another person.
7
D4SL-N / D4SL-NSK10-LK@
Structure and Nomenclature
Structure
D4SL-N@@@@-D@N Connector Type D4SL-@@@@-D@ Terminal Block Type
Two operation key holes Two operation key holes
Connector/Terminal
Terminal Arrengement
for D4SL-N@N@@-D@
9 E1 (+)
10 E2 (−)
2 41 12 11 1
42
1 2 3 4 5 6 10 <LED> 4 52 51 22 21 3
ORANGE
8 64 63 34 33 5
Notched side is No. 1 7 6
1 3 5 7 9
2 4 6 8 10
Note: Numbers inside the boxes are terminal
numbers printed on the product.
8
D4SL-N / D4SL-NSK10-LK@
Return to
condition 1
Door open. Door closed. Door closed. Door closed.
The door will lock The door is locked. The door can be No power is supplied
when the door closes. opened. to the solenoid.
Terminal No. and The door is unlocked
Contact No. Function manually.
9 E1- 10 E2 Solenoid ON
2 42- 1 11 (NC) Door open/closed detection
4 52- 3 21 (NC) and lock monitor contacts
3 21- 4 22 (NC) Door open/closed detection
5 31- 6 32 (NC) contact
5 33- 6 34 (NO)
Door open/closed detection
contact
The shaded areas indicate
1 41- 2 42 (NC) the contact is closed and
Lock monitor contact
7 61- 8 62 (NC) power is supplied to the
7 63- 8 64 (NO) Lock monitor contact solenoid.
Door open/closed detection and lock monitor contacts: Can be used in safety circuits because of the direct opening mechanisms.
Door open/closed detection contact: Can be used to confirm whether the key is inserted and to monitor the open/closed status of a door.
Lock monitor contact: Can be used to confirm whether power is supplied to the solenoid and to monitor whether or not a door can be opened or closed.
Note: 1. The door open/closed detection and lock monitor contact configuration depends on the model.
2. If a current is detected in the solenoid lock model (built-in switches; N, P, Q, R), before the door is closed, the door will remain unlocked.
Be sure to supply power to the solenoid after the door is closed.
9
D4SL-N / D4SL-NSK10-LK@
Specifications
Standards and EC Directives
Conforms to the following EC Directives:
• Machinery Directive
• Low Voltage Directive
• EMC Directive
• EN1088
• EN60204-1
• GS-ET-19
Certified Standards
Certification body Standard File No.
TÜV SÜD EN60947-5-1(certified direct opening)
Consult your OMRON representative for details.
UL UL508, CSA C22.2 No.14
CQC (CCC) GB14048.5 pending
KOSHA *1 EN60947-5-1 Consult your OMRON representative for details.
*1. Only certain models have been certified.
R150
Current (A) Volt-amperes (VA)
Rated voltage Carry current
Make Break Make Break
125 VDC 1.0 A 0.22 0.22 28 28
Indicator
Item LED type
Rated voltage 24 VDC
Current consumption Approx.10 mA
Color (LED) Orange
10
D4SL-N / D4SL-NSK10-LK@
Characteristics
Degree of protection *1 IP67 (EN60947-5-1)
Mechanical 1,000,000 operations min.
Durability *2
Electrical 150,000 operations min. (1 A resistance at 125 VAC) *3
Operating speed 0.05 to 1 m/s
Operating frequency 5 operations minute max.
Direct opening force *4 60 N min. (EN60947-5-1)
Direct opening travel *4 15 mm min. (EN60947-5-1)
Holding force *5 1,300 N min.
Contact resistance 200 mΩ max.
Minimum applicable load *6 1 mA resistive load at 5 VDC (N-level reference value)
Rated insulation voltage (Ui) 150 V (EN60947-5-1)
Rated frequency 50/60 Hz
Protection against electric shock Class II (double insulation)
Pollution degree (operating environment) 3 (EN60947-5-1)
Between terminals of same polarity 1.5 kV
Impulse
Between terminals of different polarity 1.5 kV
withstand voltage
(EN60947-5-1) Between other terminals and
2.5 kV
non-current carrying metallic parts
Insulation resistance 100 Ω min. (at 500 VDC)
Vibration resistance Malfunction 10 to 55 Hz, 0.35 mm single amplitude
Malfunction 80 m/s2 min.
Shock resistance
Destruction 1,000 m/s2 min.
Conditional short-circuit current 100 A (EN60947-5-1)
2.5A (11-42, 21-52, 21-22)
Conventional free air thermal current (Ith)
1A (Others)
Ambient operating temperature −10 to 55°C (with no icing)
Ambient operations humidity 95% max.
Head: Resin
Approx. 290 g (Connector model)
Approx. 330 g (Terminal block model)
Weight
Head: Metal
Approx. 370 g (Connector model)
Approx. 410 g (Terminal block model)
Note: 1. The above values are initial values.
2. The Switch contacts can be used with either standard loads or microloads.
Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads.
The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1).
Confirm that sealing properties are sufficient for the operating conditions and environment beforehand.
Although the switch box is protected from dust, oil or water penetration, do not use the D4SL in places where cutting chips, oil, water or
chemicals may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON
representative.
*3. Do not pass the 1 A, 125 VAC load through more than 3 circuits.
*4. These figures are minimum requirements for safe operation.
*5. This figure is based on the GS-ET-19 evaluation method.
*6. This value will vary with the switching frequency, environment, and reliability level.
Confirm that correct operation is possible with the actual load beforehand.
11
D4SL-N / D4SL-NSK10-LK@
Connection
Internal Circuit Diagram
Without indicator With indicator
24VDC D 24VDC D
E1 (+) E1 (+)
R
Control Control
ZD D ZD D
circuit circuit
LED
E2 (−) E2 (−)
E1 E1
9 (+) 9
Door open/ (+) Door open/
LED closed detection LED closed detection
10 E2 switch E2 switch
10
(−) (−)
2 41 12 1 To safety circuit 2 41 12 1 To safety circuit
42 11 42 11
4 22 3 To safety circuit 4 51 22 3 To safety circuit
21 52 21
8 64 63 34 5 To control circuit 8 64 63 34 5 To control circuit
33 33
12
D4SL-N / D4SL-NSK10-LK@
Contact Form
Indicates conditions where the Key is inserted and the lock is applied.
Contact Contact Form
(door open/ Door open/
Model Lock Operating pattern Remarks
closed detection closed
and lock monitor) monitor
detection
Lock position
Door open/closed Only NC contact 11-12 has a
Lock monitor detection 42-11 certified direct opening
42 41 12 11 34-33 On mechanism.
D4SL-N@B@@-@ 1NC/1NO+2NC 62-61 The terminals 42-11, 34-33, and
Stroke 62-61 can be used as unlike
Operation Key Insertion Extraction
62 61 34 33
completion position completion position
poles.
Lock position
Door open/closed Only NC contact 11-12 and 31-
Lock monitor detection
42-11 32 has a certified direct opening
42 41 12 11 32-31 On mechanism.
D4SL-N@C@@-@ 2NC+1NC/1NO 64-63 The terminals 42-11, 32-31, and
Stroke 64-63 can be used as unlike
Operation Key Insertion Extraction
64 63 32 31
completion position completion position
poles.
Lock position
Door open/closed Only NC contact 11-12 and 31-
Lock monitor detection
42-11 32 has a certified direct opening
42 41 12 11 32-31 On mechanism.
D4SL-N@D@@-@ 2NC+2NC 62-61 The terminals 42-11, 32-31, and
Stroke 62-61 can be used as unlike
Operation Key Insertion Extraction
62 61 32 31
completion position completion position
poles.
Lock position
Door open/closed Only NC contact 21-22 has a
Lock monitor detection 42-41
certified direct opening
22-21
1NC/1NO+ 42 41 On mechanism.
D4SL-N@S@@-@ 34-33
1NC/1NO 64-63
The terminals 42-41, 22-21, 34-
22 21 33, and 64-63 can be used as
Stroke
64 63 34 33 Operation Key Insertion Extraction unlike poles.
completion position completion position
Lock position
Door open/closed Only NC contact 21-22 has a
Lock monitor detection 42-41
certified direct opening
22-21
42 41 On mechanism.
D4SL-N@T@@-@ 1NC/1NO+2NC 34-33
62-61
The terminals 42-11, 22-21, 34-
22 21 33, and 62-61 can be used as
Stroke
62 61 34 33 Operation Key Insertion Extraction unlike poles.
completion position completion position
Lock position
Door open/closed Only NC contact 21-22 and 31-
Lock monitor detection 42-41
32 has a certified direct opening
22-21
42 41 On mechanism.
D4SL-N@U@@-@ 2NC+1NC/1NO 32-31
64-63
The terminals 42-11, 22-21, 32-
22 21 31, and 64-63 can be used as
Stroke
64 63 32 31 Operation Key Insertion Extraction unlike poles.
completion position completion position
Lock position
Door open/closed Only NC contact 21-22 and 31-
Lock monitor detection 42-41
32 has a certified direct opening
22-21
42 41 On mechanism.
D4SL-N@V@@-@ 2NC+2NC 32-31
62-61
The terminals 42-11, 22-21, 32-
22 21 31, and 62-61 can be used as
Stroke
62 61 32 31 Operation Key Insertion Extraction unlike poles.
completion position completion position
13
D4SL-N / D4SL-NSK10-LK@
Lock position
Door open/closed Only NC contact 11-12 and 21-
Lock monitor detection 42-11
22 has a certified direct opening
22-21
42 41 12 11 On mechanism.
D4SL-N@F@@-@ 2NC/1NO+2NC 34-33
62-61
The terminals 42-11, 22-21, 34-
22 21 33, and 62-61 can be used as
Stroke
62 61 34 33 Operation Key Insertion Extraction unlike poles.
completion position completion position
Lock position
Door open/closed Only NC contact 11-12 ,21-22
Lock monitor detection 42-11
and 31-32 has a certified direct
22-21
42 41 12 11 On opening mechanism.
D4SL-N@G@@-@ 3NC+1NC/1NO 32-31
64-63
The terminals 42-11, 22-21, 32-
22 21 31, and 64-63 can be used as
Stroke
64 63 32 31 Operation Key Insertion Extraction unlike poles.
completion position completion position
Lock position
Door open/closed Only NC contact 11-12 ,21-22
Lock monitor detection 42-11
and 31-32 has a certified direct
22-21
42 41 12 11 On opening mechanism.
D4SL-N@H@@-@ 3NC+2NC 32-31
62-61
The terminals 42-11, 22-21, 32-
22 21 31, and 62-61 can be used as
Stroke
62 61 32 31 Operation Key Insertion Extraction unlike poles.
completion position completion position
Lock position
Door open/closed Only NC contact 11-12 and 21-
Lock monitor detection 42-11
22 has a certified direct opening
52-21
2NC/1NO+ 42 41 12 11 On mechanism.
D4SL-N@N@@-@ 34-33
2NC/1NO 64-63
The terminals 42-11, 52-21, 34-
52 51 22 21 33, and 64-63 can be used as
Stroke
64 63 34 33 Operation Key Insertion Extraction unlike poles.
completion position completion position
Lock position
Door open/closed Only NC contact 11-12 and 21-
Lock monitor detection 42-11
22 has a certified direct opening
52-21
42 41 12 11 On mechanism.
D4SL-N@P@@-@ 2NC/1NO+3NC 34-33
62-61
The terminals 42-11, 52-21, 34-
52 51 22 21 33, and 62-61 can be used as
Stroke
62 61 34 33 Operation Key Insertion Extraction unlike poles.
completion position completion position
Lock position
Door open/closed
Only NC contact 11-12 ,21-22
Lock monitor detection 42-11 and 31-32 has a certified direct
52-21 opening mechanism.
42 41 12 11 On
D4SL-N@Q@@-@ 3NC+2NC/1NO 32-31 The terminals 42-11, 52-21, 32-
52 51 22 21
64-63 31, and 64-63 can be used as
Stroke unlike poles.
64 63 32 31 Operation Key Insertion Extraction
completion position completion position
Lock position
Door open/closed Only NC contact 11-12 ,21-22
Lock monitor detection 42-11
and 31-32 has a certified direct
52-21
42 41 12 11 On opening mechanism.
D4SL-N@R@@-@ 3NC+3NC 32-31
62-61
The terminals 42-11, 52-21, 32-
52 51 22 21 31, and 62-61 can be used as
Stroke
62 61 32 31 Operation Key Insertion Extraction unlike poles.
completion position completion position
14
D4SL-N / D4SL-NSK10-LK@
Dimensions and Operating Characteristics (Unit:mm)
Switches
D4SL-N@@@@-@N (Connector Type)
29.2
Head cap 29.2
9
Pre-travel distance
B
Operation Key 39
A
37 Side mounting
Front-side mounting
26.3 26.3 22±0.2 Three, 4.3 dia.
Two, 4.3 dia. 39
Mounting hole 10 Mounting hole
Spacers
4.5 dia. 42.9
22±0.2 4 31.5 38.7±0.2 38.5
(depth: 1.6)
B-B A-A B
26 dia.
A
Conduit cap One, Conduit
Model
D4SL-N@@@@-@N
Operating characteristics
Key insertion force 15 N max.
Key extraction force 30 N max. Two, Cover mounting screw
Pre-travel distance 15 mm max.
Movement before being locked 3 mm min.
9
Pre-travel distance
B
39
Operation Key
A 37
Front-side mounting 22±0.2 Side mounting
26.3 26.3 Two, 4.3 dia. Three, 4.3 dia.
39 10
Mounting hole Mounting hole
Spacers
4.5 dia. 42.9
22±0.2 4 31.5 38.7±0.2 38.5
(depth: 1.6)
Model
D4SL-N@@@@-@
Operating characteristics
Key insertion force 15 N max.
Two, Cover mounting screw
Key extraction force 30 N max.
Pre-travel distance 15 mm max.
Movement before being locked 3 mm min.
15
D4SL-N / D4SL-NSK10-LK@
Operation key
D4SL-NK1 D4SL-NK1S
28 29 19.5
21.5 29
7 13
7
35 15 22.7
35 15 22.7
7
4.3 7
Four, R2.15 4.3
Four, R2.15
2
2
D4SL-NK1G D4SL-NK2
28 29
21.5 15.6 14.5
29
8
7
35 20 12 22.7
35 22.7 15
2 2
Mounting rubber
D4SL-NK2G D4SL-NK3
17.2 14.5
29
8
35 22.7 12 20
17.7
29
4.5 dia. 15 Angle adjustment bolt
4
Two, 4.3 dia. Two, 9 dia.
8 dia.
9 dia.
22.7 30 40 56
2
20°
Mounting rubber
Connector Cables
D4SL-CN@
(30) L ±40 (150) Model L size
10
9
8
(5)
7
6
D4SL-CN1 1m
5
4
3 D4SL-CN3 3m
2
1
Cable *
AWG22, 10 conductors
D4SL-CN5 5m
Connector pin No. Connector
* All 10 lead wires laid bare.
Connector No. Lead wire color Connector No. Lead wire color
1 Black 6 Green/White
2 Black/White 7 Yellow
3 Red 8 Yellow/White
4 Red/White 9 Brown
5 Green 10 Brown/White
16
D4SL-N / D4SL-NSK10-LK@
Slide Key
D4SL-NSK10-LK
Open door Close door
10
40×40
12.5
Lockout key
(26.8)
(314) (232.2) (81.8) (71.8)
(35) (30.2)
(147) (112) 19.1
(35) 107 8
15+10
−5 (Between Slide Key)
(20)
11.5
B B Shot bolt
(56.5) SLIDE
LOCK
SLIDE
LOCK
17
50 (64)
SLIDE SLIDE
FREE FREE
20 (90.4)
(76.2)
Guide
38.7 (32.5)
Four, M6
Slide base mounting holes
D4SL-NK1S Three, M4
22 Operation Key
(330)
11.5
Two, M6 11.6
12.5 mounting holes Switch base
D4SL-NSK10-LKH
Open door Close door
10
Aluminum frame
40×40
12.5
Lockout key
(323) (71.8)
(35) (26.8) (39.2)
(147) (121) (241.2) (81.8) 19.1
(35) 107
15+10
−5 (Between Slide Key)
(20) 8
40
11.5
B B Shot bolt
(115)
(56.5) SLIDE
LOCK
SLIDE
LOCK (78)
17
SLIDE
50 (64) SLIDE
FREE FREE
20 90.4
12 dia.
(76.2) 40 dia.
38.7 (32.5) Guide Inner Lever
Four, M6
Slide base mounting holes
D4SL-NK1S
22 Operation Key Three, M4
330 4
17
D4SL-N / D4SL-NSK10-LK@
D4SL-N+D4SL-NK1
With Front-inserted Operation Key With Top-inserted Operation Key
Horizontal
59 min. insertion radius
(37) >180
61.5 max. R=
Key insertion
position
(15)
Center tolerance of
key hole: ±0.8 Horizontal Vertical
insertion radius insertion radius Center tolerance of
R>=180 Center tolerance of
R>=200 key hole: ±0.8
Vertical (15) key hole: ±0.8 9
insertion radius
59 min. (37) >200
R=
61.5 max.
Key insertion 60.5 min. 60.5 min.
position 63 max. 63 max.
Key insertion Key insertion
(38.5) position (38.5)
31.5 position
Center tolerance of
key hole: ±0.8
D4SL-N+D4SL-NK1S
With Front-inserted Operation Key With Top-inserted Operation Key
Horizontal
50.5 min. insertion radius
(37) >180
53 max. R=
Key insertion
position
(15)
Center tolerance of
key hole: ±0.8 Horizontal Vertical
insertion radius insertion radius Center tolerance of
R>=180 Center tolerance of
R>=200 key hole: ±0.8
Vertical (15) key hole: ±0.8
insertion radius 9
50.5 min. (37) >200
R=
53 max.
Key insertion 52 min. 52 min.
position 54.5 max. 54.5 max.
(38.5) Key insertion (38.5) Key insertion
31.5 position
position
Center tolerance of
key hole: ±0.8
D4SL-N+D4SL-NK1G
With Front-inserted Operation Key With Top-inserted Operation Key
Horizontal
59 min. insertion radius
(37) >120
61.5 max. Pitch 12 mm R=
Pitch 20 mm R> =170
Key insertion
position
Horizontal
(Pitch 12 mm) Center tolerance of insertion radius
(Pitch 20 mm) key hole: ±0.8 >120 Center tolerance of Vertical Center tolerance of
Pitch 12 mm R=
key hole: ±0.8 insertion radius key hole: ±0.8
Pitch 20 mm R> =170
(Pitch 12 mm) R>=140
Vertical (Pitch 20 mm) 9
59 min. insertion radius (6.4)
(37) >140
61.5max. R=
Key insertion 60.5 min. 60.5 min.
position 63 max. 63 max.
Key insertion Key insertion
(38.5) (38.5)
(28.9) 31.5 position position
Center tolerance of
key hole: ±0.8
18
D4SL-N / D4SL-NSK10-LK@
D4SL-N+D4SL-K2
With Front-inserted Operation Key With Top-inserted Operation Key
Horizontal
53.1 min. insertion radius
(37)
55.6 max. R>=180
Key insertion
position
Key insertion
54.6 min. 54.6 min.
position
57.1 max. 57.1 max.
Key insertion Key insertion
31.5 (39.5) (38.5) (38.5)
position position
Center tolerance of
key hole: ±0.8
D4SL-N+D4SL-NK2G
With Front-inserted Operation Key With Top-inserted Operation Key
Horizontal
insertion radius
54.7 min. (37) >120
Pitch 12 mm R=
57.2 max. >170
Pitch 20 mm R=
Key insertion
position
Horizontal
(Pitch 12 mm) Center tolerance of
insertion radius
(Pitch 20 mm) key hole: ±0.8 Center tolerance of Vertical Center tolerance of
Pitch 12 mm R> =120 key hole: ±0.8 insertion radius key hole: ±0.8
Pitch 20 mm R> =170 (Pitch 12 mm) R>=140
Vertical (Pitch 20 mm) (21.5)
54.7 min. insertion radius 9
57.2 max. (37) >140
R=
Key insertion
56.2 min. 56.2 min.
position
58.7 max. 58.7 max.
Key insertion Key insertion
31.5 (39.5) (38.5) (38.5)
position position
Center tolerance of
key hole: ±0.8
D4SL-N+D4SL-NK3
With Front-inserted Operation Key With Top-inserted Operation Key
Horizontal
55.2 min. insertion radius
55.7 max. (37) >50
R=
Key insertion
position
(40±0.15)
Center tolerance of
key hole: ±0.8
19
D4SL-N / D4SL-NSK10-LK@
Application Example
G9SA-321-T@ (24VAC/VDC) +D4SL-N@R@A-@ (Mechanical Lock Type) / Manual Reset
11
1 2 3 4 5 6 7 8 to PLC
to PLC
Guard
S1
Feedback loop
OPEN
KM1
S3 KM2
Stop signal
1 3
TH K3 4
a K1 K2 K3 1
SA 2
a K4 3
4
K1 OffDelay Control 2 K1 JP 5
b K4 5 6
K2 Timer Circuit
K2
b
6
PE T21 T23 T22 A B 14 24 34 44 54 62
KM1 KM2
Timing Chart
(Operation instruction)
Guard opens Motor controller
Limit switch S1
Guard Lock KM1
Safety-door Switch S2
S4
Guard can be opened
Stop signal
M
Reset switch S3
K3 and K4 (NO)
Operation instruction
Motor rotation
OFF-delay time
20
D4SL-N / D4SL-NSK10-LK@
Lock signal
S2 S1: Safety Limit Switch with direct opening mechanism
9 10 (D4B-N, D4N or D4F)
S2: D4SL-N
42
KM1 and KM2: Magnetic Contactor
41 M: 3-phase motor
12
11
1 2 3 4 5 6 7 8 to PLC
to PLC
S1
12 Feedback loop
OPEN 11 KM1
KM2
Operation signal
6
PE T21 T23 T22 A B 14 24 34 42
KM1 KM2
(Operation instruction)
Motor controller
KM1
Timing Chart
Guard opens
KM2
Limit switch S1
Guard Lock
Safety-door Switch S2
Operation signal M
Lock signal
Note: 1. This circuit diagram is for Category 4.
K1 and K2 (NC) 2. The lock can be released at any time. Therefore, do not use a
model with a solenoid lock in applications where the operator
K1 and K2 (NO)
may be exposed to danger when the guard opens. Use a model
KM1 and KM2 (NC)
with a mechanical lock.
3. Numbers inside the boxes are terminal numbers printed on the
KM1 and KM2 (NO) product.
21
D4SL-N / D4SL-NSK10-LK@
Safety Precautions
Be sure to read the precautions for All Safety Door Switches in the website at:http://www.ia.omron.com/.
CAUTION Installation
• Make sure the Switch is mounted securely to prevent it from falling
D4SL-N
off. Otherwise injury may result.
Injury may occasionally occur. When the Switch • Do not use a Switch as a stopper. Head Stopper
function is damaged, some machines may continue Be sure to install a stopper as shown in the
operating in situations where they should be stopped. following illustration so that the Operation
Key does not touch the head.
Do not impose a force exceeding the key holding
Do not subject the Switch to a shock that
force.
exceeds the Switch's shock resistance of
Always provide a lock separate from the Switch, Operation Key
1,000 m/s2.
attach a warning seal to avoid excessive force applied
to the Switch, or provide an indicator lamp to show the Switch
locked/unlocked status of the door.
D4SL-NSK10-LK@
Do not use this product mounted so that it slides
vertically.
This may cause malfunction, resulting in personal
injury.
22
D4SL-N / D4SL-NSK10-LK@
D4SL-NSK10-LK@
• Do not drop the Product. Doing so may prevent the Product from Precautions for Correct Use
functioning to full capacity.
D4SL-N
• Mount the Product securely to prevent it from falling. Otherwise,
injury may occur.
Solenoid Lock Models
• Do not attempt to disassemble or modify the Switch. Doing so may • Be sure to supply power to the solenoid after the door is closed
cause the Switch to malfunction. (after the Operation Key is inserted).
• Make sure that the gap between the shot bolt and the guide is ±0.5 • The solenoid lock locks the door only when power is supplied to the
mm. solenoid. Therefore, the door will be unlocked if the power supply
Otherwise, excessive wear or damage may cause malfunction. to the solenoid stops. Therefore, do not use solenoid lock models
• To ensure safety, do not operate the Switch with anything other for machines that may be operating and dangerous even after the
than the Slide Key Unit. machine stops operating.
• Your hand may be injured by being pinched between the Operation
Key and Switch when closing the door with your hand on the
Release Key
• The release key is used to unlock the Switch in case of emergency
Product.
• Be careful to avoid pinching your hand when operating the Slide or if the power supply to the Switch stops.
• If the release key setting is changed from LOCK to UNLOCK, the
Handle.
lock will be released and the safety door can be opened
• Do not impose a force of exceeding 1 N•m when operating the
Lockout Key. (mechanical lock models only).
Å@
Otherwise, the Product may be damaged and may not operate Front
properly. D4SL-N@@@@-@ D4SL-N@@@@-@4
To prevent damage, attach the supplied labels for display near the
Product. LOCK LOCK
• Do not force the slide handle to move when the lockout key is not
inserted. Doing so may damage the product and make operation
impossible.
• Do not force the slide handle to move when the door is locked.
Doing so may damage the product and make operation impossible.
• Do not close the door with the shot bolt removed. Doing so may
damage the product and make operation impossible.
• Turn the Lockout Key to the "SLIDE LOCK" position and remove it
when opening the door to prevent a third party from operating the UNLOCK UNLOCK
Slide Handle.
• The durability of the Switch varies considerably depending on the
Back
switching conditions. Always confirm the usage conditions by using
D4SL-N@@@@-@ D4SL-N@@@@-@4
the Switch in an actual application, and use the Switch only for the
number of switching operations given in the performance
LOCK LOCK
specifications.
• The user must not maintain or repair equipment incorporating the
Switch. Contact the manufacturer of the equipment for any
maintenance or repairs required.
• Refer to the D4SL-N Guard Lock Safety-door Switch Instruction
Sheet about storage conditions, ambient conditions,
Switch details, and handling methods.
• Do not apply excessive force in the direction of the slide. This may
damage the product and cause it to malfunction.
• Do not force the switch or cable. This may SLIDE
LOCK
• After setting the release key to UNLOCK to, for example, perform
maintenance, be sure to return it to LOCK setting before resuming
operation.
• The release key is set in the unlock position at the factory for the
D4SL-N@@@A and to the lock position for the D4SL-N@@@G.
• In the unlock position, even when the door of large machines or
stamping machines is closed during preliminary adjustment, the
door will remain unlocked and the machines will not be activated.
• Do not use the release key to start or stop machines.
• The auxiliary lock must be released only by authorized personnel.
• Do not impose a force exceeding 0.2 N•m on the release key
screws. The release key may be damaged and may not operate
properly.
• To prevent the release key from being used by unauthorized
personnel, set it to LOCK and seal it with sealing wax.
Mounting Covers
• Confirm that the seal rubber has no defects before use. If the seal
rubber is displaced or raised, or has foreign particles adhered to it,
the sealing capability of the seal rubber will be adversely affected.
23
D4SL-N / D4SL-NSK10-LK@
D4SL-NK3 Two, M4 E1
9 (+) Door open/
41.7±0.15 LED closed detection
10 E2 switch
40±0.1 (−)
2 41 12 11 1 To safety circuit
42
4±0.1 dia. 1.5 max.
4 52 51 22 21 3 To safety circuit
• Do not impose excessive force on the key top while the operation 8 63 34 33 5 To control circuit
64
key is inserted into the switch body or drop the switch with the
Lock monitor
operation key inserted to avoid the deformation of the key or the switch
7 6
24
D4SL-N / D4SL-NSK10-LK@
1 2 3 4 5 6 10
1 2 10
30±3 mm
• Do not pull on the lead wires with excessive force. Doing so may
disconnect them.
• Do not forcibly insert the wired socket at the cable side into the
connector or D4SL-N’s conduit opening. Doing so may cause
cable break.
Be sure to insert the cable into the connector or D4SL’s conduit
opening before performing wiring to the socket, or insert the cable
into the connector or conduit opening from the opposite side of the
socket.
25
D4SL-N / D4SL-NSK10-LK@
Nomenclature
Hexagonal nut (M6)
Slide Key Unit Handle mounting screw
Spring washer (TORX_T30/M6)
Guide (M6)
Shot Bolt Fig.1
Slide Base
2) Mounting of inner lever
Tighten A portion of the inner lever to a suitable torque with wrench
(width across flat: 10mm).
26
READ AND UNDERSTAND THIS CATALOG
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions
or comments.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the
customer’s application or use of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply
to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end
product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all
possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may
represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject
to the OMRON Warranty and Limitations of Liability.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or
reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in
its entirety.
OMRON Corporation Industrial Automation Company Authorized Distributor:
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V. OMRON SCIENTIFIC TECHNOLOGIES INC.
Wegalaan 67-69-2132 JD Hoofddorp 6550 Dumbarton Circle,
The Netherlands Fremont, CA 94555-3605 U.S.A.
Tel: (31)2356-81-300/Fax: (31)2356-81-388 Tel: (1) 510-608-3400/Fax: (1) 510-744-1442
OMRON ASIA PACIFIC PTE. LTD. OMRON (CHINA) CO., LTD. © OMRON Corporation 2012 All Rights Reserved.
No. 438A Alexandra Road # 05-05/08 (Lobby 2), Room 2211, Bank of China Tower, In the interest of product improvement,
Alexandra Technopark, 200 Yin Cheng Zhong Road, specifications are subject to change without notice.
Singapore 119967 PuDong New Area, Shanghai, 200120, China CSM_1_2_0512
Tel: (65) 6835-3011/Fax: (65) 6835-2711 Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 Cat. No. C146-E1-01 0512 (0412)
Mouser Electronics
Authorized Distributor
Omron:
D4SL-N3QFA-D D4SL-N2HFA-D D4SL-N3NFG-DN D4SL-N3NFA-DN D4SL-N4AFG D4SL-N4SFG D4SL-N2GFA-
D D4SL-N3VFA D4SL-N3NFG-D D4SL-N3VFG D4SL-N2AFG D4SL-N3NFG-D4 D4SL-N4GFA-D D4SL-N4HFG-D
D4SL-N2FFA-D D4SL-N2NFA-DN D4SL-N2RFA-D D4SL-N2VFG D4SL-N3AFG D4SL-N3HFG-DN D4SL-N3QFA-
DN D4SL-N3RFG-D D4SL-NK5 D4SL-N4FFA-D D4SL-N3NFA-D4N D4SL-N3NFG-D4N D4SL-N3PFA-D D4SL-
N3PFA-D4N D4SL-N3PFA-DN D4SL-N3PFG-D D4SL-N4PFG-D4 D4SL-N4QFA-D4 D4SL-N4QFG-D4 D4SL-
N4RFA-D4 D4SL-N4RFG-D4 D4SL-N4GFG-D4 D4SL-N4HFA-D4 D4SL-N4HFG-D4 D4SL-N4NFA-D4 D4SL-
N4NFG-D4 D4SL-N4PFA-D4 D4SL-N3RFG-D4 D4SL-N4EFA-D4 D4SL-N4EFG-D4 D4SL-N4FFA-D4 D4SL-
N4FFG-D4 D4SL-N4GFA-D4 D4SL-N3HFG-D4 D4SL-N3PFA-D4 D4SL-N3PFG-D4 D4SL-N3QFA-D4 D4SL-
N3QFG-D4 D4SL-N3RFA-D4 D4SL-N3EFG-D4 D4SL-N3FFA-D4 D4SL-N3FFG-D4 D4SL-N3GFA-D4 D4SL-
N3GFG-D4 D4SL-N3HFA-D4 D4SL-N2PFG-D4 D4SL-N2QFA-D4 D4SL-N2QFG-D4 D4SL-N2RFA-D4 D4SL-
N2RFG-D4 D4SL-N3EFA-D4 D4SL-N2GFG-D4 D4SL-N2HFA-D4 D4SL-N2HFG-D4 D4SL-N2NFA-D4 D4SL-
N2NFG-D4 D4SL-N2PFA-D4 D4SL-N3NFA-D4 D4SL-N2EFA-D4 D4SL-N2EFG-D4 D4SL-N2FFA-D4 D4SL-N2FFG-
D4 D4SL-N2GFA-D4 D4SL-N3GFG-DN D4SL-N3HFA-D D4SL-N3HFA-D4N D4SL-N3HFA-DN D4SL-N3HFG-D
D4SL-N3HFG-D4N D4SL-N3FFG-DN D4SL-N3GFA-D D4SL-N3GFA-D4N D4SL-N3GFA-DN D4SL-N3GFG-D
D4SL-N3GFG-D4N D4SL-N3EFG-DN D4SL-N3FFA-D D4SL-N3FFA-D4N D4SL-N3FFA-DN D4SL-N3FFG-D D4SL-
N3FFG-D4N D4SL-N3DFG-N D4SL-N3EFA-D D4SL-N3EFA-D4N D4SL-N3EFA-DN D4SL-N3EFG-D