SPECIFICATIONS

FIGURE X10P & X11P


PIPING PRODUCTS

LOW-LEAD COMPLIANT WATER HAMMER ARRESTORS


FNW water hammer arrestors are engineered devices that provide
maintenance-free continuous protection against water hammer.
Water hammer is a hydraulic shock wave generated within a
water distribution system due to a sudden stop in water flow. If
allowed to exist for any length of time, water hammer can cause
pipes to rattle, is capable of bursting pipes or can damage other
components within the system. When installed properly, there is
an unobstructed shock path to the arrestor that is absorbed by a
piston-driven and isolated cushion of air.

FEATURES
• Lead-free certified
• Max Static (Working) Pressure: 150 psi
• Max Spike Pressure: 350 psi
• Temperature: 33°F to 180°F (0.6°C to 82°C)
• End Connection: NPT (X10P), CxC (X11P)
• For commercial and residential systems
• Suitable for potable water applications
• Designed for vertical or horizontal installation (not to be installed
in the inverted position)
• Can be installed in systems without need for access panels*
* Always check local plumbing codes to determine if access panels are required.
Sweat version not to be used in conjunction with copper propress system due to
brass connection.

PRODUCT SPECIFICATIONS
Low-Lead Compliant: Referring to laws defining "Lead-Free" as wetted surface of
Standards pipe, fittings and fixtures in potable water systems that have a weighted average
lead content ≤ 0.25% per the Safe Drinking Water Act (Sec. 1417) amended 1-4-2011
• Federal Safe Drinking Water Act, Sec. 1417 (Lead-Free) as well as other state regulations.
• ASSE Standard 1010
• IAPMO Listed (cUPC)

SIZING/PDI FIXTURE UNITS** FIGURE NUMBER MATRIX

PDI Size Code


Size PDI Fixture Units FNW — —
X10P X11P END SIZE

1/2" A A 1–11 END TYPE SIZE CODE


3/4" B B 12–32 1/2 = 500
1" C C 33–60 Male NPT (1/2" to 2") = X10P 3/4 = 750
1-1/4" D D 61–113 1 = 1000
Copper Sweat (1/2" to 1-1/4") = X11P 1-1/4 = 1250
1-1/2" E — 114–154
1-1/2 = 1500
2" F — 155–330 2 = 2000
**As outlined in The Plumbing and Drainage Institute Standard PDI-WH 201.
See the FNW water hammer arrestor IOM for more details.

FNW.COM We reserve the right to modify or improve the designs or


specifications of our products at any time without notice.
SPECIFICATIONS

FIGURE X10P & X11P


PIPING PRODUCTS

LOW-LEAD COMPLIANT WATER HAMMER ARRESTORS

FIG. X10P FIG. X11P

A A
2
2
4
4
3
3
1 C
1 C
B
B

STANDARD MATERIALS DIMENSIONS (INCHES)

Ref. No. Description Material Qty Fig. 10P Fig. 11P


Size
Lead-Free Brass, A B (NPT) C A B C
1 Body 1
C46400
1/2 4.75 1/2–14 0.63 4.96 0.625 0.72
2 Cylinder Copper C12200 1
3/4 5.37 3/4–14 0.65 5.57 0.875 0.80
3 Piston PP+30% Fiber 1
1 6.70 1–1-1/2 0.74 6.85 1.125 0.98
4 O-Ring EPDM 2
1-1/4 8.20 1-1/4–11-1/2 0.88 8.30 1.375 1.10
1-1/2 9.40 1-1/2–11-1/2 0.94 — — —
2 9.40 2–11-1/2 0.94 — — —

FNW.COM We reserve the right to modify or improve the designs or


©2024 Ferguson Enterprises, LLC 0224 6168101 specifications of our products at any time without notice.