MxPro5 Declaration of Performance

This document is a Declaration of Performance for various models of Fire Detection and Fire Alarm Panels manufactured by Advanced Electronics Ltd, in compliance with the Construction Products Regulation EU No 305/2011. It details the intended use, models, assessment systems, harmonised standards, and the performance characteristics of the products, all of which have passed the relevant testing. The declaration confirms that the products meet the specified performance criteria and is signed by the Product Conformance Manager.

Uploaded by

amitpramanik
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
59 views3 pages

MxPro5 Declaration of Performance

This document is a Declaration of Performance for various models of Fire Detection and Fire Alarm Panels manufactured by Advanced Electronics Ltd, in compliance with the Construction Products Regulation EU No 305/2011. It details the intended use, models, assessment systems, harmonised standards, and the performance characteristics of the products, all of which have passed the relevant testing. The declaration confirms that the products meet the specified performance criteria and is signed by the Product Conformance Manager.

Uploaded by

amitpramanik
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

In accordance with Construction Products Regulation EU No 305/2011

Declaration of Performance No: 5000


[1] Product Type
Series Fire Detection and Fire Alarm Panel
Series Fire Detection and Fire Alarm Panel

[2] Models
Loops
Mx-5101 – may be followed by M, L, D, R
MX-520x – may be followed by L, D, R x = 1-2
Mx-540x – may be followed by D, E, R x = 1-4
Mx-580x – may be followed by FT x = 2-8
Mx-5101A – may be followed by M, L, D, R
MX-520xA – may be followed by L, D, R x = 1-2
Mx-540xA – may be followed by D, E, R x = 1-4
Mx-580xA – may be followed by FT x = 2-8
Mx-5101H – may be followed by M, L, D, R
MX-520xH – may be followed by L, D, R x = 1-2
Mx-540xH – may be followed by D, E, R x = 1-4
Mx-580xH – may be followed by FT x = 2-8
Mx-5101N – may be followed by M, L, D, R
MX-520xN – may be followed by L, D, R x = 1-2
Mx-540xN – may be followed by D, E, R x = 1-4
Mx-580xN – may be followed by FT x = 2-8
Mx-5101V – may be followed by M, L, D, R
MX-520xV – may be followed by L, D, R x = 1-2
Mx-540xV – may be followed by D, E, R x = 1-4
Mx-580xV – may be followed by FT x = 2-8
Axis-5101 – may be followed by M, L, D, R
Axis-520x – may be followed by L, D, R x = 1-2
Axis-540x – may be followed by D, E, R x = 1-4
Axis-580x – may be followed by FT x = 2-8

[3] Intended Use:


Fire Safety – Fire detection and fire alarm systems

www.advancedco.com
[4] Manufactured by:
Advanced Electronics Ltd,
The Bridges, Balliol Business Park,
Newcastle-Upon-Tyne.
NE12 8EW

[5] Authorised Representative


Not applicable

[6] System of Assessment and verification of constancy of performance


System 1

[7] Harmonised Standards


FM Approvals Europe Limited 2809 performed initial type testing and initial inspection of the manufacturing plant
and factory production control, and performs continuous surveillance of the factory production control under system
1 and has issued a certificate of conformity 2809-CPR-E0011 to:

EN54-2:1997 +A1:2006, EN54-4:1997 +A1:2002 +A2:2006

[8] European Technical Assessment


Not applicable

www.advancedco.com
[9] Declared Performance
Essential Characteristic Performance Harmonised technical specification
Performance under fire conditions Pass EN54-2:1997 +A1:2006, Clauses 4, 5, 7
Response delay (response time to fire) Pass EN54-2:1997 +A1:2006, Clauses 7.1, 7.7, 7.11, 7.12
Operational reliability
General requirements Pass EN54-2:1997 +A1:2006, Clause 4
General requirements for indications Pass EN54-2:1997 +A1:2006, Clause 5
The quiescent condition Pass EN54-2:1997 +A1:2006, Clause 6
The fire alarm condition Pass EN54-2:1997 +A1:2006, Clauses 7.1, 7.2, 7.3, 7.4, 7.5, 7.6, 7.7
Output to fire alarm devices Pass EN54-2:1997 +A1:2006, Clause 7.8
Control of fire alarm routing equipment Pass EN54-2:1997 +A1:2006, Clause 7.9
Outputs to fire protection equipment Pass EN54-2:1997 +A1:2006, Clause 7.10
Delays to outputs Pass EN54-2:1997 +A1:2006, Clause 7.11
Dependencies on more than one alarm signal Pass EN54-2:1997 +A1:2006, Clause 7.12
Alarm Counter Pass EN54-2:1997 +A1:2006, Clause 7.13
The fault warning condition Pass EN54-2:1997 +A1:2006, Clauses 8.1, 8.2, 8.3, 8.5, 8.6, 8.7, 8.8
Total loss of power supply NPD EN54-2:1997 +A1:2006, Clause 8.4
Output to fault warning routing equipment Pass EN54-2:1997 +A1:2006, Clause 8.9
Disablement of addressable points Pass EN54-2:1997 +A1:2006, Clause 9.5
Test condition Pass EN54-2:1997 +A1:2006, Clause 10
Standardised input / output interface Pass EN54-2:1997 +A1:2006, Clause 11
Design requirements Pass EN54-2:1997 +A1:2006, Clause12
Additional design requirements for software controlled Pass EN54-2:1997 +A1:2006, Clause 13
control and indicating equipment
Marking Pass EN54-2:1997 +A1:2006, Clause 14
Operational reliability Pass EN54-4:1997 +A1:2002+A2:2006, Clauses 4, 5, 6, 7, 8
Performance of power supply Pass EN54-4:1997 +A1:2002+A2:2006, Clauses 4, 5, 6
Durability of operational reliability, Temperature Pass EN54-2:1997 +A1:2006, Clause 15.4
resistance EN54-4:1997 +A1:2002+A2:2006, Clause 9.5
Durability of operational reliability, Vibration Pass EN54-2:1997 +A1:2006, Clauses 15.6, 15.7, 15.15
resistance EN54-4:1997 +A1:2002+A2:2006, Clauses 9.7, 9.8, 9.15
Durability of operational reliability, Electrical Pass EN54-2:1997 +A1:2006, Clauses 15.8 to 15.13
stability EN54-4:1997 +A1:2002+A2:2006, Clauses 9.9 to 9.13
Durability of operational reliability, Humidity Pass EN54-2:1997 +A1:2006, Clauses 15.5, 15.14
resistance EN54-4:1997 +A1:2002+A2:2006, Clauses 9.6, 9.14

[10] Authority
The performance of the product(s) identified in points 1 and 2 is (are) in conformity with the declared performance
detailed in point 9.
This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 4.
Signed for and on behalf of the manufacturer by:

David Wilson (Product Conformance Manager) – Newcastle-upon-Tyne

20th August 2019

www.advancedco.com