0% found this document useful (0 votes)
10 views1 page

14 621820 4800000763 Sib Ele SHD 117103 - DWG - 02 14 621820 4800000763 Sib Ele SHD 117103

The document is a detailed shop drawing for an electrical, earthing, and lightning protection system for a residential plot in NEOM, Saudi Arabia. It includes proposed placements for equipment, stairways, and other structural elements, along with general notes, symbols, and abbreviations. The drawing is intended for approval and outlines the scope of work and specific references related to the project.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views1 page

14 621820 4800000763 Sib Ele SHD 117103 - DWG - 02 14 621820 4800000763 Sib Ele SHD 117103

The document is a detailed shop drawing for an electrical, earthing, and lightning protection system for a residential plot in NEOM, Saudi Arabia. It includes proposed placements for equipment, stairways, and other structural elements, along with general notes, symbols, and abbreviations. The drawing is intended for approval and outlines the scope of work and specific references related to the project.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1 2 3 4 5

GENERAL KEY PLAN:


N

QIBLA
30-AM-5

32-E-5

29-AM-5

31-BM-5
24-BM-5

35-A-5
33-D-5

34-A-5

23-AM-5
26-B-5
17-AM-5
25-A-5

28-B-5
18-B-5

16-C-5
27-A-5

20-BM-5

19-C-5
22-A-5

TAPE CLIP CTC02 21-C-5

E Air Terminal
DC Clip ROOF FLOOR 13-G-4

14-GM-4

COPPER TAPE
(BELBCT250350)
BARE COPPER TAPE RUN Proposed 15-G-4

TOP OF PARAPET (TYPICAL) placement 4-GM-3

DC TAPE CLIP 1-G-2

(BELCTC02) PARAPET WALL of stair. Not 3-GM-3

included in 7-GM-4
8-G-4

AIR ROD BASE CAB01 the Sibs 2-GM-3


5-G-4
6-G-4
10-H-4
11-GM-4

Scope. 9-H-4

12-GM-4

AIR ROD BASE BELCAB01

ROOF FLOOR
Air Terminal Saddle -

WM
41.0 m²
GR-0 20
SQUARE CLAMP

1BR
NOTES:
HEIGHT OF
AIR TERMINAL

W
PR

F
HEIGHT OF OT
EC
PARAPET WALL TE DA
RE
A COPPER TAPE CLIP CTC02 OR ADHESIVE TAPE CLIP CXNP01 AC

EQUIPMENT

PVC COPPER TAPE

WM
41.0 m²
GR-019
1BR

W
F
AC

D
COLUMN

WM
41.0 m²
GR-018
1BR
MM
00
X 20
MA

REFERENCE NUMBER DESCRIPTION

W
F
AC
14-621820-4800000763-SIB-ELE-SHD-000003 GENERAL NOTES, SYMBOLS & ABBREVIATIONS
14-621820-4800000763-SIB-ELE-SHD-000013 DRAWING SHEET LIST

240 L

240 L

240 L

240 L

240 L
Proposed
placement 0m 2m 4m 6m 8m 10m

GR-025
of stair. Not Waste Management 22.2 m^2
included in

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF NEOM. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT FROM NEOM.
the Sibs GR-022
Scope. VISUAL SCALE 1:100 @ A1
STAGE:
AC

4A - SHOP DRAWING

WM
02 4A - SHOP DRAWING RG 12.02.2025

41.0 m²
GR-017
01 4A - SHOP DRAWING RG 17.05.2024

1BR
REV DESCRIPTION APP DATE
PURPOSE OF ISSUE:

W
C

F
AC

FOR APPROVAL
CLIENT: PROJECT MANAGEMENT CONSULTANT:

WM
D:\NC1\ENGINEERING\LIGHTNING\SHOP DRAWING\REV 1 & 2\14-621820-4800000763-SIB-ELE-SHD-117103_DWG_02.dwg

41.0 m²
GR-016
1BR

W
F
AC

WM
DESIGN CONSULTANT NAME & LOGO (s): CONTRACTOR NAME & LOGO (s):

41.0 m²
Proposed placement of stair and ramp. Not included in the Sibs Scope.

GR-015
1BR
1:12 (4,7°) 1:12 (4,7°)

W
F
AC

GR-023

B DESIGN CONSULTANT / CONTRACTOR: NEOM'S REVIEW:


DRAWN: HB 12.02.2025
Proposed GR-0 24 Proposed CHECKED: RK 12.02.2025 CHECKED: CHK DD.MM.YYYY
placement 1BR 1BR 1BR 1BR 1BR 1BR 1BR 1BR 1BR 1BR 1BR 1BR 1BR 1BR
placement
of stair. Not 41.0 m² 41.0 m² 41.0 m² 41.0 m² 41.0 m² 41.0 m² 41.0 m² 41.0 m² 41.0 m² 41.0 m² 41.0 m² 41.0 m² 41.0 m² 41.0 m² APPROVED: RG 12.02.2025 APPROVED: APR DD.MM.YYYY
GR-0 01 GR-0 02 GR-003 GR-0 04 GR-0 05 GR-0 06 GR-0 07 GR-0 08 GR-0 09 GR-010 GR-011 GR-012 GR-013 of stair. Not
included in GR-014
included in
the Sibs the Sibs
Scope. Scope. SCALE: 1:100 SHEET SIZE: A1
DISCIPLINE NAME:
ELECTRICAL, EARTHING AND LIGHTNING PROTECTION
F F F F F F F F F F F F F F
RESIDENTIAL PLOT - BUILDING 17, 23, 29, 30
Tele & CTV
11.1m^2 BLDG TYPE AM-5, GROUND FLOOR PLAN
PROJECT NAME:
WM WM WM WM WM WM WM WM WM WM WM WM WM WM
GR-0 21 GR-017

W W W W W W W W W W W W W W
HIGH DENSITY EXPANSION - RESIDENTIAL
W W W W W W W W W W W W W W
NEOM COMMUNITY - NC1
W W W W W W W W W W W W W W

W W W W W W W W
Electric
W W W W W W NEOM
A 8.7 m^2
KINGDOM OF SAUDI ARABIA
REGION ASSET CODE CONTRACT CODE
24/02/2025 4:45:51 PM

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC
14 621820 4800000763
DRAWING NUMBER
ORIGINATOR DISCIPLINE DOCUMENT TYPE SEQUENTIAL NUMBER REV NO.

SIB ELE SHD 117103 02


NEOM-NEN-PRC-010_TMP02_02.00