THE FOLLOWING SAMPLE(S) WAS/WERE SUBMITTED AND IDENTIFIED BY/ON BEHALF OF THE CUSTOMER AS :
DISCIPLINE Chemical
GROUP Hazardous & Restricted Chemicals
SAMPLE DESCRIPTION ECOMET CORUNDUM
COLOUR SILVER
OEM OTHER
COUNTRY OF ORIGIN INDIA
DATE OF REGISTRATION 20/10/2023 TESTING PERIOD : 25/10/2023 – 30/10/2023
TEST(S) REQUESTED ROHS 10E
CONCLUSION : Based on the performed tests on selected part of submitted samples, the results of Lead, Mercury,
Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBBs), Polybrominated diphenyl ethers
(PBDEs) and Phthalates such as Bis(2-ethylhexyl) phthalate (DEHP), Butyl benzyl phthalate (BBP),
Dibutyl phthalate (DBP) and Diisobutyl phthalate (DIBP) comply with the limits as set by Directive (EU)
2015/863 amending Annex II to Directive 2011/65/EU.
SACHIN M. VIBHUTE
Sr.Executive
Authorized Signatory
Email your Test Report Related Enquiries at [email protected]
Transportation Laboratory, Gat No. : 239/1/3, Village Khalumbre, Tal. Khed, Dist- Pune, Chakan – 410501, Maharashtra, India,
SGS India Private Ltd Phone: +91 2135 615300, Fax: +91 2135 615333 www.sgs.com
Member of the SGS Group (SGS SA)
ULR -TC582523000017449F TEST REPORT
Report No. : PN:TR:1454017341 ISSUE DATE : 01/11/2023
*1454017341*
- - ECOMET CORUNDUM -
Test Method:
(1) With reference to IEC 62321-5:2013, determination of Cadmium by ICP-OES.
(2) With reference to IEC 62321-5:2013, determination of Lead by ICP-OES.
(3) With reference to IEC 62321-4:2017-07, determination of Mercury by ICP-OES.
(4) With reference to IEC 62321-7-2:2017, determination of Hexavalent Chromium in colorless
& colored corrosion- protected coatings on metals by the colorimetric method.
(5) With reference to IEC 62321-6:2015-06, determination of PBBs and PBDEs by GC-MS.
(6) With reference to IEC 62321-8:2017-03, determination of phthalates by GC-MS.
Transportation Laboratory, Gat No. : 239/1/3, Village Khalumbre, Tal. Khed, Dist- Pune, Chakan – 410501, Maharashtra, India,
SGS India Private Ltd Phone: +91 2135 615300, Fax: +91 2135 615333 www.sgs.com
Member of the SGS Group (SGS SA)
ULR -TC582523000017449F TEST REPORT
Report No. : PN:TR:1454017341 ISSUE DATE : 01/11/2023
*1454017341*
Test result:
Acceptance
Test Item(s): Unit Results Reporting Limit
Criteria
Cadmium(Cd) mg/kg n.d. 5 100
Lead (Pb) mg/kg n.d. 5 1000
Mercury (Hg) mg/kg n.d. 5 1000
Hexavalent Chromium (CrVI) mg/kg n.d. 8 1000
Sum of PBBs mg/kg n.d. - 1000
Monobromobiphenyl mg/kg n.d. 50 -
Dibromobiphenyl mg/kg n.d. 50 -
Tribromobiphenyl mg/kg n.d. 50 -
Tetrabromobiphenyl mg/kg n.d. 50 -
Hexabromobiphenyl mg/kg n.d. 50 -
Pentabromobiphenyl mg/kg n.d. 50 -
Heptabromobiphenyl mg/kg n.d. 50 -
Octabromobiphenyl mg/kg n.d. 50 -
Nonabromobiphenyl mg/kg n.d. 50 -
Decabromobiphenyl mg/kg n.d. 50 -
Sum of PBDEs mg/kg n.d. - 1000
Monobromodiphenyl ether mg/kg n.d. 50 -
Dibromodiphenyl ether mg/kg n.d. 50 -
Tribromodiphenyl ether mg/kg n.d. 50 -
Tetrabromodiphenyl ether mg/kg n.d. 50 -
Pentabromodiphenyl ether mg/kg n.d. 50 -
Hexabromodiphenyl ether mg/kg n.d. 50 -
Heptabromodiphenyl ether mg/kg n.d. 50 -
Octabromodiphenyl ether mg/kg n.d. 50 -
Nonabromodiphenyl ether mg/kg n.d. 50 -
Decabromodiphenyl ether mg/kg n.d. 50 -
Phthalates
Dibutyl phthalate (DBP) mg/kg n.d. 100 1000
Butyl benzyl phthalate (BBP) mg/kg n.d. 100 1000
Bis (2-ethylhexyl) phthalate (DEHP) mg/kg n.d. 100 1000
Diisobutyl Phthalates (DIBP) mg/kg n.d. 100 1000
Remarks:
(1) 1mg/kg=0.0001%
(2) n.d = not detected (<Reporting Limit)
(3) - = not regulated
JOE No. : 2354803820 Page -3 of 9 Control No.:1454514568
“This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
http://www.sgsgroup.in/Service-Terms and, for electronic format documents, subject to Terms and Conditions for Electronic Documents a www.sgs.com/terms_e-document.htm.
Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon
reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this
document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except
in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders
may be prosecuted to the fullest extent of the law. The laboratory shall be responsible for all the information provided in the report, except when information and instruction for
specific scope of testing is provided by the customer.”
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days. from the date of issue of report .The
samples from the regulatory bodies are to be retained as specified.This document cannot be reproduced,except in full,without prior written approval of the company.
Transportation Laboratory, Gat No. : 239/1/3, Village Khalumbre, Tal. Khed, Dist- Pune, Chakan – 410501, Maharashtra, India,
SGS India Private Ltd Phone: +91 2135 615300, Fax: +91 2135 615333 www.sgs.com
Member of the SGS Group (SGS SA)
ULR -TC582523000017449F TEST REPORT
Report No. : PN:TR:1454017341 ISSUE DATE : 01/11/2023
*1454017341*
Notes:
(1) The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863.
IEC 62321 series is equivalent to EN 62321 series
http://www.cenelec.eu/dyn/www/f?p=104:30:1742232870351101::::FSP_ORG_ID,FSP_LANG_ID:1258637,25
(2) The result of Hexavalent Chromium (Cr(VI)) is “n.d.” as the result of Chromium (Cr) is “n.d,”, and confirmation test
of Hexavalent Chromium (Cr(VI)) is not required.
(3) If the Chromium (Cr) content is greater than the Reporting Limit of Hexavalent Chromium (Cr(VI)), confirmation test
of Hexavalent Chromium (Cr(VI)) is required.
(4) On 4 June 2015, Commission Directive (EU) 2015/863 was published in the Official Journal of the European Union
(OJEU) to include the phthalates BBP, DBP, DEHP and DIBP into ANNEX II of the Rohs Recast Directive. The new
law restricts each phthalate to no more than 0.1% in each homogeneous material of an electrical product.
(5) The restriction of DEHP, BBP, DBP and DIBP shall apply to medical devices, including in vitro medical devices, and
monitoring and control instruments, including industrial monitoring and control instruments, from 22 July 2021.
(6) The restriction of DEHP, BBP, DBP and DIBP shall not apply to cables or spare parts for the repair, the reuse, the
updating of functionalities or upgrading of capacity of EEE placed on the market before 22 July 2019, and of
medical devices, including in vitro medical devices, and monitoring and control instruments, including industrial
monitoring and control instruments, placed on the market before 22 July 2021.
(7) The restriction of DEHP, BBP and DBP shall not apply to toys which are already subject to the restriction of DEHP,
BBP and DBP through entry 51 of Annex XVII to Regulation (EC) No 1907/2006.
Transportation Laboratory, Gat No. : 239/1/3, Village Khalumbre, Tal. Khed, Dist- Pune, Chakan – 410501, Maharashtra, India,
SGS India Private Ltd Phone: +91 2135 615300, Fax: +91 2135 615333 www.sgs.com
Member of the SGS Group (SGS SA)
ULR -TC582523000017449F TEST REPORT
Report No. : PN:TR:1454017341 ISSUE DATE : 01/11/2023
*1454017341*
Process Flow for analysis of metal contents in plastics, metals and electronic components sample
Sample preparation,
0.10 – 0.3 g
Cool down
Cool down
Add 0.25 g
orthoboric acid
Filtration
50 ml final volume
ICP-OES
Transportation Laboratory, Gat No. : 239/1/3, Village Khalumbre, Tal. Khed, Dist- Pune, Chakan – 410501, Maharashtra, India,
SGS India Private Ltd Phone: +91 2135 615300, Fax: +91 2135 615333 www.sgs.com
Member of the SGS Group (SGS SA)
ULR -TC582523000017449F TEST REPORT
Report No. : PN:TR:1454017341 ISSUE DATE : 01/11/2023
*1454017341*
Process Flow for analysis of Flame Retardants in plastics, metals and electronic components sample
Sample
Sample Pretreatment
Soxhlet extraction
USEPA 3540C/3550/IEC
62321-6:2015
Concentrate/Dilute
Extracted solution
Filter if necessary
Transportation Laboratory, Gat No. : 239/1/3, Village Khalumbre, Tal. Khed, Dist- Pune, Chakan – 410501, Maharashtra, India,
SGS India Private Ltd Phone: +91 2135 615300, Fax: +91 2135 615333 www.sgs.com
Member of the SGS Group (SGS SA)
ULR -TC582523000017449F TEST REPORT
Report No. : PN:TR:1454017341 ISSUE DATE : 01/11/2023
*1454017341*
Process Flow for analysis of Hexavalent Chromium contents in plastics, metals and electronic
components sample
Sample
Data
Transportation Laboratory, Gat No. : 239/1/3, Village Khalumbre, Tal. Khed, Dist- Pune, Chakan – 410501, Maharashtra, India,
SGS India Private Ltd Phone: +91 2135 615300, Fax: +91 2135 615333 www.sgs.com
Member of the SGS Group (SGS SA)
ULR -TC582523000017449F TEST REPORT
Report No. : PN:TR:1454017341 ISSUE DATE : 01/11/2023
*1454017341*
Process Flow for analysis of Phthalates in Electrotechnical Product As per soxhelt Extraction or THF
Extraction:
Sample
Sample Pretreatment
Sample Pretreatment
Addition THF
Concentrate/Dilute
Extracted solution Addition of Acetonitrile
Filter if necessary
Filter if necessary
On GCMS-Sample Analyzed
On GCMS-Sample Analyzed
Data
Transportation Laboratory, Gat No. : 239/1/3, Village Khalumbre, Tal. Khed, Dist- Pune, Chakan – 410501, Maharashtra, India,
SGS India Private Ltd Phone: +91 2135 615300, Fax: +91 2135 615333 www.sgs.com
Member of the SGS Group (SGS SA)
ULR -TC582523000017449F TEST REPORT
Report No. : PN:TR:1454017341 ISSUE DATE : 01/11/2023
*1454017341*
Sample Photo:
Transportation Laboratory, Gat No. : 239/1/3, Village Khalumbre, Tal. Khed, Dist- Pune, Chakan – 410501, Maharashtra, India,
SGS India Private Ltd Phone: +91 2135 615300, Fax: +91 2135 615333 www.sgs.com
Member of the SGS Group (SGS SA)