The BERMAD MUT2300 is an advanced electromagnetic flowmeter designed for water cycle and process applications, offering high accuracy and the ability to measure low flow rates even in challenging conditions. It operates based on the Faraday Principle and features a robust design with an IP68 protection rating, making it suitable for permanent immersion. The sensor is compatible with various converters and is certified for custody transfer, ensuring reliability and precision in diverse applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
12 views16 pages

WW MUT2300-Euromag Product-Page English 7-2019

The BERMAD MUT2300 is an advanced electromagnetic flowmeter designed for water cycle and process applications, offering high accuracy and the ability to measure low flow rates even in challenging conditions. It operates based on the Faraday Principle and features a robust design with an IP68 protection rating, making it suitable for permanent immersion. The sensor is compatible with various converters and is certified for custody transfer, ensuring reliability and precision in diverse applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

BERMAD Meters

Merging monitoring & control

Sensor
MUT2300
Euromag Electromagnetic Flowmeter
BERMAD Meters

Sensor MUT2300
The MUT2300 sensors represent the state of the art
of Euromag International production for water cycle
and process applications. The innovative inner part of
the sensor that increase considerably the liquid flow
rate and the reading accuracy of signal generated to
the electrodes, enables an extremely wide range of
measurement.

These performances allow to measure also low flow rates


precisely and repeatable, even in difficult/problematic
applications with solid parts.

This flanged sensor series bases its operation on


the Faraday Principle, by which a conductor crossing
a magnetic field generates an electrical potential
perpendicular to the field itself. On the top and on the
lower side of the stainless steel AISI 304 flow tube,
two coils are installed; the magnetic field generated
by the electric current crossing the coils, induces in
the electrodes a potential difference proportional to
the flow rate.

With the aim of measuring such potential of very


low values, the interior of the flow tube is electrically
insulated, thus the process liquid is no longer in contact
neither with the material of the flow tube nor with
that of the flanges.

The converter used generates the current supplying


the coils, acquires the electrodes potential difference,
process the signal to calculate the flowrate and manages
all the communications. The entire sensor has an IP68
protection degree suitable for a permanent immersion
in water up to a depth of 1.5m.

|2|
Euromag Sensor MUT2300

The electromagnetic flowmeter designed for the toughest applications

DS401-1-ENG

|3|
BERMAD Meters

Body and flanges


The flanges and the sensor external surface are flowmeters, thanks to its unique design, projected
acrylic painted. This treatment gives the sensor an to accelerate the flow and amplify the signal to the
excellent resistance to water and external agents electrodes, guarantees a pressure drop less than 250
even in permanent immersion or buried. The MUT2300 mbar at velocity of 8 m/s. The pressure drop is always
may be supplied in stainless steel, flanges included, less than 10 mbar at velocities lower than 1 m/s.
or with a special paint ideal for application in C4 class
environment (UNI EN ISO 12944-2).

Internal lining
The standard internal insulating lining is in Hard rubber
(Ebonite) in compliance with WRAS, FDA and DM174
standards. The liquid temperature can reach 80°C.
Thanks to its high resistance to scraping, the Ebonite
is considered the best material for fluids containing
scattered solids for applications of water treatment,
residual water, potable water and irrigation.

Electrodes
The standard electrodes are in Hastelloy C and therefore
MUT2300 - MC406
this guarantees a wide compatibily with process fluids. If VERTICAL
required, they may be supplied in Hastelloy B, Titanium,
Tantalum and Platinum. A partially empty tube detection
(fourth electrode) is installed and can be enabled or
disabled through the software.

Coupling and connection


to the sensor
MUT2300 sensors may be coupled with any Euromag
MUT2300 - MC406
converters. In the separate version the sensor is
VERTICAL
connected to the converter through a cable whose
length depends on the liquid conductivity; the maximum
length must not exceed 100 metres on the powered
version and 30 metres on the battery version.

Neglectable pressure drop


The electromagnetic flowmeters do not have any moving
internal parts, thus they have a very low pressure drop.
The OIML R-49 permits a maximum pressure drop of
630 mbar at velocity of about 8 m/s. The MUT2300 MUT2300 - MC608A

|4|
Euromag Sensor MUT2300

Installation with Standards reference


no upstream The Euromag magnetic meters are marked CE and are
manufactured according to the following standards:
and downstream • 2014/35/EU - EN 61010-1:2013 (LVD)

distances • 2014/30/EU - EN 61326-1:2013 (EMC)

• OIML R49-1:2013
The cone shaped section of the internal part of the
sensor, allows an optimized and accelerated flow • European directive 2014/32/EU (MID)
profile which permits to install the sensor in any kind of
• 2014/34/UE - IEC 60079 - 0, IEC 60079 -
condition; no need to have straight sections/segments of
18 (ATEX - IECEx) Separate version
pipes upstream and downstream. This U0-D0 condition
enables to have an extreme flexibility on the flowmeter • EN ISO 15609-1 and EN ISO 15614-1
installation position. • UNI EN ISO 12944-2, painting for C4 class environments
(on request)

• Ebonite conform to the norms WRAS, FDA e DM174

|5|
BERMAD Meters

Applications Advantages
• Measure of potable or reflow water • No moving parts • No parts inside of the flowmeter
• No obstruction on the flow tube • Very low pressure
• Distribution, municipal water
loss (below 1 m/s is irrelevant) • Long lasting stability
• Industrial waste water and precision, no filter needed, zero maintenance • No
periodic cleaning • Accurate measure at high flow rate
• Over night applications with very low flow rate (firefighting systems) and at low flow rates (overnight

• Industrial process liquids, muds and concretes flow rates) • Extremely sturdy structure, a dedicated
robot welds all the parts, internal parts protected by
• Installation in small places without straight distances a bi-component resin in order to increase protection
from external agents • Ideal for pit installations even for
• Leakage detection
pemr anent immersion in water or buried installations
• Fiscal measures, irrigation • Bi-directional measure

Technical features MUT2300


Flow tube material AISI 304, AISI 316 (optional)
Flanges material Carbon steel (S235JR - 1.0037), AISI 304 optional, AISI 316 optional
Available electrodes Hastelloy C (standard), Hastelloy B, Titanium, Tantalum, Platinum
Internal lining Ebonite
Liquid temperature -40°C / + 80°C
mm 50 65 80 100 125 150 200 250 300
Available diameters
inches 2” 2½” 3” 4” 5” 6” 8” 10” 12”
Standard flanged connections EN1092-1 PN 16, ANSI 150
Flanged connections on request AS 2129 (Table D, E, F), AS 4087 (PN 16, 21), KS10K, others on request
Standard operation pressure 21 bar
DN≤80 DN≥100
Pressure drop class
ΔP25 (< 0.25 bar) ΔP40 (< 0.40 bar)
Installation requirements/conditions U0-D0
Protection Degree IP68 permanent submersion at 1.5 m (EN 60529)
Convertes compatibility MC608A/B/R/P, MC406
Electrical connections Cableglands M20 x 1.5 + terminal box + sealing resin

|6|
Euromag Sensor MUT2300

Calibration and maximum error


MUT2300 sensors belong to the reference Group B1 (ISO 11631). Each sensor is calibrated by an hydraulic bench
equipped with a reference weighting system and ACCREDIA certified. The uncertainty of the calibration is equal
to 0.2% ± 2mm/s. The repeatability of the measure is about 0.1%. Bi-directional measure. Furthermore the
sensors are certified MID01 norms (if coupled to MC406 converters) for custody transfer.

Flow rates chart


Maximum Permissible Error is within the limits indicated
Flow [m3/h]
Sensor Ratio
diameter Q3/Q1 in the following graph:
Min Q1 Trans. Q2 Q0.4% Perm. Q3 Overl. Q4

DN50 - 2" 0.125 0.20 3.50 25.00 31.25 200

DN65 - 2½" 0.20 0.32 6.00 40.00 50.00 200

DN80 - 3" 0.315 0.50 9.00 63.00 78.75 200

DN100 - 4" 0.50 0.80 14.00 100.00 125.00 200

DN125 - 5" 0.80 1.28 22.00 160.00 200.00 200

DN150 - 6" 1.25 2.00 32.00 250.00 312.50 200

DN200 - 8" 3.15 5.04 57.00 630.00 787.50 200

DN250 - 10" 5.00 8.00 90.00 1000.00 1250.00 200

DN300 - 12" 8.00 12.50 128.00 1000.00 1250.00 125

|7|
BERMAD Meters

MUT2300 - MC406 HORIZONTAL

MC406 HORIZONTAL

DN H H1

50 - (2”) 62 187

65 - (2½") 62 187

80 - (3") 71 196

100 - (4") 79 204

125 - (5") 106 231

150 - (6") 101 226

200 - (8") 147 272

250 - (10") 176 301

300 - (12") 207 332

|8|
Euromag Sensor MUT2300

MUT2300 - MC406 VERTICAL

MC406 VERTICAL

DN H H1

50 - (2”) 62 188

65 - (2½") 62 188

80 - (3") 71 197

100 - (4") 79 205

125 - (5") 106 232

150 - (6") 101 227

200 - (8") 147 273

250 - (10") 176 302

300 - (12") 207 333

|9|
BERMAD Meters

MUT2300 - MC608 A/B/R

MC608 A/B/R

DN H H1

50 - (2”) 62 211

65 - (2½") 62 211

80 - (3") 71 220

100 - (4") 79 228

125 - (5") 106 255

150 - (6") 101 250

200 - (8") 147 296

250 - (10") 176 325

300 - (12") 207 356

| 10 |
Euromag Sensor MUT2300

MUT2300 - SEPARATE

MUT2300 - EN 1092 / PN 16

DN D5 L4 j Di D6 N S H

50 85 200 (+0/-3) 87.35 30.4 125 4 18 114.5

65 85 200 (+0/-3) 87.35 34.3 145 4 18 114.5

80 103 200 (+0/-3) 96.35 46.3 160 4 18 123.5

100 118 250 (+0/-3) 103.85 62.1 180 8 18 131

125 172 250 (+0/-3) 130.85 74.9 210 8 18 158

150 163 300 (+0/-3) 126.35 100 240 8 22 153.5

200 255 350 (+0/-3) 172.35 154.3 295 8 22 199.5

250 312 450 (+0/-5) 200.85 205 350 12 22 228

300 375 500 (+0/-5) 232.35 259 400 12 22 259.5

| 11 |
BERMAD Meters

MUT2300 - ANSI 150


DN D5 L4 j Di D6 N S H
2” - (DN 50) 85 200 (+0/-3) 87.35 30.4 120.65 4 19.05 114.5
2½" - (DN 65) 85 200 (+0/-3) 87.35 34.3 139.7 4 19.05 114.5
3" - (DN 80) 103 200 (+0/-3) 96.35 46.3 152.4 4 19.05 123.5
4" - (DN 100) 118 250 (+0/-3) 103.85 62.1 190.5 8 19.05 131
5" - (DN 125) 172 250 (+0/-3) 130.85 74.9 215.9 8 22.352 158
6" - (DN 150) 163 300 (+0/-3) 126.35 100 241.3 8 22.352 153.5
8" - (DN 200) 255 350 (+0/-3) 172.35 154.3 298.45 8 22.352 199.5
10" - (DN 250) 312 450 (+0/-5) 200.85 205 361.95 12 25.4 228
12" - (DN 300) 375 500 (+0/-5) 232.35 259 431.8 12 25.4 259.5

MUT2300 - AS 2129 / Table D


DN D5 L4 j Di D6 N S H
50 85 200 (+0/-3) 87.35 30.4 114 4 18 114.5
65 85 200 (+0/-3) 87.35 34.3 127 4 18 114.5
80 103 200 (+0/-3) 96.35 46.3 146 4 18 123.5
100 118 250 (+0/-3) 103.85 62.1 178 4 18 131
125 172 250 (+0/-3) 130.85 74.9 210 8 18 158
150 163 300 (+0/-3) 126.35 100 235 8 18 153.5
200 255 350 (+0/-3) 172.35 154.3 292 8 18 199.5
250 312 450 (+0/-5) 200.85 205 356 8 22 228
300 375 500 (+0/-5) 232.35 259 406 12 22 259.5

MUT2300 - AS 2129 / Table E


DN D5 L4 j Di D6 N S H
50 85 200 (+0/-3) 87.35 30.4 114 4 18 114.5
65 85 200 (+0/-3) 87.35 34.3 127 4 18 114.5
80 103 200 (+0/-3) 96.35 46.3 146 8 18 123.5
100 118 250 (+0/-3) 103.85 62.1 178 8 18 131
125 172 250 (+0/-3) 130.85 74.9 210 8 18 158
150 163 300 (+0/-3) 126.35 100 235 8 22 153.5
200 255 350 (+0/-3) 172.35 154.3 292 8 22 199.5
250 312 450 (+0/-5) 200.85 205 356 12 22 228
300 375 500 (+0/-5) 232.35 259 406 12 26 259.5

MUT2300 - AS 4087 / PN 16
DN D5 L4 j Di D6 N S H
50 85 200 (+0/-3) 87.35 30.4 114 4 18 114.5
65 85 200 (+0/-3) 87.35 34.3 127 4 18 114.5
80 103 200 (+0/-3) 96.35 46.3 146 8 18 123.5
100 118 250 (+0/-3) 103.85 62.1 178 4 18 131
125 172 250 (+0/-3) 130.85 74.9 210 8 18 158
150 163 300 (+0/-3) 126.35 100 235 8 18 153.5
200 255 350 (+0/-3) 172.35 154.3 292 8 18 199.5
250 312 450 (+0/-5) 200.85 205 356 8 22 228
300 375 500 (+0/-5) 232.35 259 406 12 22 259.5

| 12 |
Euromag Sensor MUT2300

| 13 |
BERMAD Meters

Zero upstream and downstream distances

| 14 |
Euromag Sensor MUT2300

| 15 |
About BERMAD
BERMAD is a leading, privately-owned global and accumulating knowledge and experience
company that designs, develops and manufactures in multiple markets and industries. Today, we are
tailor-made water & flow management solutions recognized as a pioneer and established world-
that include state-of-the-art hydraulic control valves, leading provider of water & flow management
air valves and advanced metering solutions. solutions that give our customers the
unprecedented operational efficiency, and superior
Founded in 1965, we have spent over 50 years quality, durability and performance they need to
interacting with the world’s major end users, meet the demanding challenges of the 21st century.

www.bermad.com
The information contained herein may be changed by BERMAD without notice. BERMAD shall not be held liable for any errors.
© Copyright 2009-2019 BERMAD CS Ltd. P CUWE 19-MU T2300

You might also like