Product data sheet RE17RMMU
Characteristics time delay relay 10 functions - 1 s..100 h -
24..240 V AC - 1 OC
Product availability: Stock - Normally stocked in distribution facility
Main
Range of product Zelio Time
Product or component Modular timing relay
type
Discrete output type Relay
Width 0.69 in (17.5 mm)
Device short name RE17R
Time delay type A
Ac
At
B
Bw
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
C
D
Di
H
Ht
Time delay range 0.1...1 s
1...10 h
1...10 min
1...10 s
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
10...100 h
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
6...60 min
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
6...60 s
Nominal output current 8A
Complementary
Contacts material Cadmium free
Control type Selector switch on front panel
[Us] rated supply voltage 24...240 V AC at 50/60 Hz
24 V DC
Voltage range 0.85...1.1 Us
Supply frequency 50...60 Hz (+/- 5 %)
Release of input voltage 10 V
Connections - terminals Screw terminals, clamping capacity: 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12
(solid) without cable end
Screw terminals, clamping capacity: 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14
(solid) without cable end
Screw terminals, clamping capacity: 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14
(flexible) with cable end
Screw terminals, clamping capacity: 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16
(flexible) with cable end
Tightening torque 5.31...8.85 lbf.in (0.6...1 N.m) conforming to IEC 60947-1
Housing material Self-extinguishing
Repeat accuracy +/- 0.5 % conforming to IEC 61812-1
Temperature drift +/- 0.05 %/°C
Voltage drift +/- 0.2 %/V
Setting accuracy of time delay +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Control signal pulse width 100 ms with load in parallel typical
30 ms typical
Insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1
Reset time 120 ms on de-energisation typical
On-load factor 100 %
Power consumption in VA 0...32 VA at 240 V AC
Aug 10, 2019
1
Power consumption in W <= 0.6 W at 24 V DC
Minimum switching current 10 mA at 5 V DC
Maximum switching current 8 A AC/DC
Maximum switching voltage 250 V AC
Breaking capacity <= 2000 VA
Operating frequency 10 Hz
Electrical durability 100000 cycles resistive load (8 A at 250 V AC maximum)
Mechanical durability 10000000 cycles
Dielectric strength 2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
[Uimp] rated impulse withstand voltage 5 kV (1.2/50 µs)
Power on delay < 100 ms
Marking CE
Creepage distance 4 kV/3 conforming to IEC 60664-1
Safety reliability data MTTFd = 296.8 years
B10d = 270000
Mounting position Any position in relation to normal vertical mounting plane
Mounting support 35 mm DIN rail conforming to EN/IEC 60715
Local signalling LED indicator on steady: relay energised, no timing in progress
LED indicator flashing: timing in progress (80 % ON and 20 % OFF)
LED indicator pulsing: relay de-energised, no timing in progress (except function
Di-D, Li-L) (5 % ON and 95 % OFF)
Product weight 0.15 lb(US) (0.07 kg)
Environment
Immunity to microbreaks <= 20 ms
Standards 2004/108/EC
EN 61000-6-1
EN 61000-6-2
EN 61000-6-3
EN 61000-6-4
IEC 61812-1
2006/95/EC
Product certifications CSA
CULus
GL
Ambient air temperature for storage -22...140 °F (-30...60 °C)
Ambient air temperature for operation -4...140 °F (-20...60 °C)
IP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
Vibration resistance 20 m/s² (f = 10...150 Hz) conforming to IEC 60068-2-6
Shock resistance 15 gn (duration = 11 ms) conforming to IEC 60068-2-27
Relative humidity 93 % without condensation conforming to IEC 60068-2-30
Electromagnetic compatibility Electrostatic discharge immunity test, in contact at 6 kV conforming to IEC
61000-4-2 level 3
Electrostatic discharge immunity test, in air at 8 kV conforming to IEC 61000-4-2
level 3
Susceptibility to electromagnetic fields, 80 MHz to 1 GHz at 10 V/m conforming to
IEC 61000-4-3 level 3
Electrical fast transient/burst immunity test, capacitive connecting clip at 1 kV
conforming to IEC 61000-4-4 level 3
Electrical fast transient/burst immunity test, direct at 2 kV conforming to IEC
61000-4-4 level 3
1.2/50 µs shock waves immunity test, differential mode at 1 kV conforming to IEC
61000-4-5 level 3
1.2/50 µs shock waves immunity test, common mode at 2 kV conforming to IEC
61000-4-5 level 3
Conducted RF disturbances, 0.15...80 MHz at 10 V conforming to IEC 61000-4-6
level 3
Voltage dips and interruptions immunity test, 1 cycle at 0 % conforming to IEC
61000-4-11
Voltage dips and interruptions immunity test, 25/30 cycles at 70 % conforming to
IEC 61000-4-11
Conducted and radiated emissions conforming to EN 55022 class B
2
Ordering and shipping details
Category 22370 - RE, RM MISC TIMERS & COUNTERS
Discount Schedule CP2
GTIN 00785901543633
Nbr. of units in pkg. 1
Package weight(Lbs) 0.17000000000000001
Returnability Y
Country of origin ID
Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW)
Compliant - since 1650 - Schneider Electric declaration of conformity Schnei-
der Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Product environmental profile Available
Product end of life instructions Available
California proposition 65 WARNING: This product can expose you to chemicals including:
- - - - - - - Substance 1 Lead and lead compounds, which is known to the State of California to cause can-
cer and birth defects or other reproductive harm.
- - - - - - - More information For more information go to www.p65warnings.ca.gov
3
Product data sheet RE17RMMU
Dimensions Drawings
Width 17.5 mm
4
Product data sheet RE17RMMU
Connections and Schema
Internal Wiring Diagram
Wiring Diagram
1) Contact Y1:
● Control for functions B, C, Ac, Bw, Ad, Ah, N, O, W, T, Tt.
● Partial stop for functions At, Ht and Pt.
● Function D if Di selected.
● Not used for functions A, H and P.
5
Product data sheet RE17RMMU
Technical Description
Function A : Power on Delay Relay
Description
The timing period T begins on energisation. After timing, the output(s) R close(s). The second output can be either timed or instantaneous.
Function: 1 Output
Function: 2 Outputs
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
Function Ac : On- and Off-Delay Relay with Control Signal
Description
After power-up, closing of the control contact C causes the timing period T to start (timing can be interrupted by operating the Gate control
contact G). At the end of this timing period, the relay closes.
When control contact C re-opens, the timing T starts.
At the end of this timing period T, the output reverts to its initial position (timing can be interrupted by operating the Gate control contact G).
The second output can be either timed or instantaneous.
Function: 1 Output
Function: 2 Outputs
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
Function At : Power on Delay Relay (Summation) with Control Signal
Description
After power-up, the first opening of control contact C starts the timing. Timing can be interrupted each time control contact closes. When the
cumulative total of time periods elapsed reaches the pre-set value T, the output relay closes.
6
Function: 1 Output
T = t1 + t2 +...
Function B : Interval Relay with Control Signal
Description
After power-up, pulsing or maintaining control contact C starts the timing T. The output R closes for the duration of the timing period T then
reverts to its initial state.
Function: 1 Output
Function Bw : Double Interval Relay with Control Signal
Description
On closing and opening of control contact C, the output R closes for the duration of the timing period T.
Function: 1 Output
Function C : Off-Delay Relay with Control Signal
Description
After power-up and closing of the control contact C, the output R closes. When control contact C re-opens, timing T starts. At the end of the
timing period, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous.
Function: 1 Output
Function: 2 Outputs
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
Function D : Symmetrical Flasher Relay (Starting Pulse Off)
Description
Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T.
The second output can be either timed or instantaneous.
7
Function: 1 Output
Function: 2 Outputs
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
Function Di : Symmetrical Flasher Relay (Starting Pulse On)
Description
Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T.
The second output can be either timed or instantaneous.
Function: 1 Output
Function: 2 Outputs
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
Function H : Interval Relay
Description
On energisation of the relay, timing period T starts and the output(s) R close(s). At the end of the timing period T, the output(s) R revert(s) to
its/their initial state. The second output can be either timed or instantaneous.
Function: 1 Output
Function: 2 Outputs
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
Function Ht : Interval Relay (Summation) with Control Signal
Description
On energisation, the output R closes for the duration of a timing period T then reverts to its initial state.
Pulsing or maintaining control contact C will again close the output R.
Timing T is only active when control contact C is released and so the output R will not revert to its initial state until after a time t1 + t2 +...
8
The relay memorises the total, cumulative opening time of control contact C and, once the set time T is reached, the output R reverts to its
initial state.
Function: 1 Output
T = t1 + t2 +...
Legend
Relay de-energised
Relay energised
Output open
Output closed
C Control contact
G Gate
R Relay or solid state output
R1/ 2 timed outputs
R2
R2 The second output is instantaneous if the right position is selected
inst.
T Timing period
Ta Adjustable On-delay
-
Tr Adjustable Off-delay
-
U Supply