No.: MD-24015-EN
Issued: 18-12-2024
Valid to: 18-12-2029
EPD
3rd PARTY VERIFIED
VERIFIZIERT
Programme Comparability
EPD Danmark EPDs of construction products may not be comparable
www.epddanmark.dk if they do not comply with the requirements in EN
15804. EPD data may not be comparable if the
datasets used are not developed in accordance with
☐ Industry -EPD EN 15804 and if the background systems are not
☒ Product -EPD based on the same database.
Validity
This EPD has been verified in accordance with ISO
Declared product(s)
14025 and is valid for 5 years from the date of issue.
This EPD covers all the products listed below that are sold under
the name SAERTEX-LINER® MULTI (with the exception of type Use
E). The production series is divided into 3 size categories: The intended use of an EPD is to communicate
scientifically based environmental information for
Small: declared product 600 mm/ 5 mm construction products, for the purpose of assessing
• Diameter: 150 mm – 1000 mm the environmental performance of buildings.
• Wall thickness: 3 mm – 6,3 mm EPD type
Medium: declared product 800 mm/ 10 mm ☐ Cradle-to-gate with modules C1-C4 and D
• Diameter: 150 mm – 1300 mm ☒ Cradle-to-gate with options, modules C1-C4 and D
• Wall thickness: 6,4 mm – 10,3 mm ☐ Cradle-to-grave and module D
Large: declared product 1200 mm/ 12 mm ☐ Cradle-to-gate
• Diameter: 150 mm – 1600 mm ☐ Cradle-to-gate with options
• Wall thickness: 10,4 mm - 15 mm
(The wall thickness refers to the combination wall thickness) CEN standard EN 15804 serves as the core PCR
Number of declared data records/product variants: 3 Product Category Rules (PCR): Construction
products, 2019:14, version 1.2.5, valid until
Production site 2024-12-20
SAERTEX multiCom GmbH Independent verification of the declaration and
Brochterbecker Damm 52 data, according to EN ISO 14025
48369 Saerbeck
☐ internal ☒ external
EPD version
This EPD is the original version.
X
A1
supply
X
Transport
A2
Product
X
Manufacturing
A3
X
Transport
A4
process
Installation
X
A5
Construction
process
Use
B1
MND
Maintenance
B2
MND Repair
B3
MND
Replacement
B4
MND
Use
Refurbishment
B5
MND
Operational
B6
MND
energy use
Life cycle stages and modules (MND = module not declared)
Operational
B7
MND
water use
De-construction
X
C1
demolition
X
Transport
C2
End of life
Waste processing
C3
Disposal
C4
Re-use, recovery
D
and recycling
potential
Beyond the
system boundary
The main product components are shown in the The products do not contain any substances on
table below. the ECHA list of Substances of Very High Concern
(SVHC).
Material Weight-% of declared
product (http://echa.europa.eu/candidate-list-table)
Glass Fibers 43,5 % - 56,1 %
Polyester Resin 34,1 % - 36,6 %
Foils 5,1 % - 11,3 %
Product(s) use
Other 2,1 % - 11,0 %
Total 100 % The liners considered in this study are used for
the trenchless rehabilitation of gravity and
Product packaging
pressure sewers.
The composition of the product's sales and
Essential characteristics
transport packaging is shown in the table below.
The liners are packed in wooden boxes in all sizes. Technical information can be requested from the
manufacturer or can be found on the
Material Weight of Weight-% of
manufacturer's website:
packaging packaging
material (kg)
Wooden Box 120 - 205 100 % www.saertex-multicom.de
Representativity
Reference Service Life (RSL)
The declared unit is 1 m³ of liner material.
Transportation and energy consumption (diesel The expected reference service life is 100 years
for generators and vehicles on the construction for gravity liner. To achieve the required product
site) for installation and removal were determined quality, a conformity assessment in accordance
and taken into account for a common process. with DIN CEN ISO/TS 23818-2 can be carried out.
As part of this conformity assessment, tests are
This declaration, including the data collection,
carried out in accordance with the quality
modeling and results, covers the manufacture of
standards specified in ISO 11296-4.
the liners at the production site in Saerbeck,
Germany. The product-specific data is based on The expected reference service life is 50 years for
average values collected for the year 2023. pressure liners. To achieve the required product
quality, a conformity assessment in accordance
The background data is based on the GaBi LCA
with DIN CEN ISO/TS 23818-2 can be carried out.
software and is less than 10 years old. In general,
As part of this conformity assessment, tests are
the background data sets used are of high quality
carried out in accordance with the quality
and the majority of the data sets are only a few
standards specified in ISO 11297-4.
years old.
The declared products cover the following product spans, which are divided into 3 categories:
Small: declared product 600 mm/ 5 mm covers the following product sizes
Medium: declared product 800 mm/ 10 mm covers the following product sizes
Large: declared product 1200 mm/ 12 mm covers the following product sizes
All products within the individual parts of the range deviate by less than 10 % from the declared
values/parameters for the environmental parameters.
Functional unit
PCR
This EPD fulfills the requirements of EN 15804 version A2:2019 for the product category construction
products.
Foreground system:
No "guarantees of origin" are used in production. Electricity consumption is modeled using a mix for
electricity that is representative of the Saerbeck production site in Germany.
Background system:
Other processes upstream and downstream of production are modeled with processes from the GaBi
background database, which is based on average data.
The process diagram below shows the life cycle of the product under consideration.
The general rules for the exclusion of inputs and Module A4 considers the transportation of the
outputs follows the requirements in EN 15804, packaged product to the construction site. A
6.3.5, where the total of neglected input flows per transportation distance of 900 km was assumed
module shall be a maximum of 5 % of energy at this point. Module A5 covers the energy
usage and mass and 1 % of energy usage and requirement in the form of diesel for preparatory
mass for unit processes. work and the installation itself, as well as the
disposal of the product packaging. A credit for
Product stage (A1-A3) includes: energy substitution through thermal utilization of
the packaging material is made in Module D.
A1 – Extraction and processing of raw materials
A2 – Transportation to the production site End of Life (C1-C4) includes:
A3 – Manufacturing process
In module C1, the energy input in the form of
The product stage comprises the acquisition of all diesel from a machine for dismantling the product
raw materials, products and energy, transport to was taken into account. Module C2 takes into
the production site, packaging and waste account the transportation of the demolition
processing up to the ”end-of-waste” state or final material to the disposal company and module C4
disposal. The LCA results are declared in the thermal recycling of the material, which was
aggregated form for the product stage, which collected before.
means, that the sub-modules A1, A2 and A3 are
declared as one module A1-A3. Re-use, recovery and recycling potential (D)
includes:
In the first step, the inner and outer liner are
produced with the glass fiber mat and combined The potential benefit of substituting fossil fuels
to form the so-called dry liner. in the course of energy generation with thermal
utilization of the product at the end of its life
The dry liner is then impregnated with a special cycle is balanced in Module D. The energy
resin mixture. The liner is then given an outer generated is credited to the system through
film and UV protection film and prepared for substitution processes, whereby it is assumed
transport. that the thermal energy would be generated
from natural gas and the substituted electricity
would correspond to the German electricity mix.
PERE [MJ] 1,20E+04 1,43E+02 5,89E+02 2,52E+03 1,50E+01 0,00E+00 4,50E+02 -4,74E+03
PERM [MJ] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
PERT [MJ] 1,20E+04 1,43E+02 5,89E+02 2,52E+03 1,50E+01 0,00E+00 4,50E+02 -4,74E+03
PENRE [MJ] 1,17E+05 2,13E+03 8,61E+03 3,77E+04 2,24E+02 0,00E+00 1,37E+03 -1,21E+04
PENRM [MJ] 2,69E+04 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
PENRT [MJ] 1,44E+05 2,13E+03 8,61E+03 3,77E+04 2,24E+02 0,00E+00 1,37E+03 -1,21E+04
RSF [MJ] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
NRSF [MJ] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
HWD [kg] 1,36E-04 3,59E-09 1,49E-08 6,35E-08 3,78E-10 0,00E+00 1,36E-08 -7,95E-07
NHWD [kg] 5,69E+02 3,19E-01 3,44E+00 5,63E+00 3,36E-02 0,00E+00 1,68E+02 -6,59E+00
RWD [kg] 1,15E+00 2,80E-03 1,30E-02 4,96E-02 2,95E-04 0,00E+00 4,60E-02 -4,74E-01
CRU [kg] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
MFR [kg] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
MER [kg] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
EEE [MJ] 3,88E+02 0,00E+00 2,76E+02 0,00E+00 0,00E+00 0,00E+00 2,60E+03 0,00E+00
EET [MJ] 9,02E+02 0,00E+00 6,47E+02 0,00E+00 0,00E+00 0,00E+00 6,04E+03 0,00E+00
HWD = Hazardous waste disposed; NHWD = Non hazardous waste disposed; RWD = Radioactive waste disposed; CRU = Components for re-
Caption use; MFR = Materials for recycling; MER = Materials for energy recovery; EEE = Exported electrical energy; EET = Exported thermal energy
PERE [MJ] 1,11E+04 1,34E+02 3,92E+02 1,05E+03 1,39E+01 0,00E+00 4,16E+02 -4,49E+03
PERM [MJ] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
PERT [MJ] 1,11E+04 1,34E+02 3,92E+02 1,05E+03 1,39E+01 0,00E+00 4,16E+02 -4,49E+03
PENRE [MJ] 1,09E+05 2,00E+03 5,62E+03 1,58E+04 2,08E+02 0,00E+00 1,27E+03 -1,15E+04
PENRM [MJ] 1,38E+04 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
PENRT [MJ] 1,23E+05 2,00E+03 5,62E+03 1,58E+04 2,08E+02 0,00E+00 1,27E+03 -1,15E+04
RSF [MJ] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
NRSF [MJ] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
HWD [kg] 7,22E-05 3,37E-09 9,92E-09 2,66E-08 3,50E-10 0,00E+00 1,25E-08 -7,55E-07
NHWD [kg] 4,88E+02 2,99E-01 3,47E+00 2,36E+00 3,11E-02 0,00E+00 1,56E+02 -6,25E+00
RWD [kg] 1,00E+00 2,63E-03 9,38E-03 2,07E-02 2,73E-04 0,00E+00 4,26E-02 -4,50E-01
CRU [kg] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
MFR [kg] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
MER [kg] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
EEE [MJ] 2,78E+02 0,00E+00 3,24E+02 0,00E+00 0,00E+00 0,00E+00 2,40E+03 0,00E+00
EET [MJ] 6,47E+02 0,00E+00 7,58E+02 0,00E+00 0,00E+00 0,00E+00 5,58E+03 0,00E+00
HWD = Hazardous waste disposed; NHWD = Non hazardous waste disposed; RWD = Radioactive waste disposed; CRU = Components for re-
Caption
use; MFR = Materials for recycling; MER = Materials for energy recovery; EEE = Exported electrical energy; EET = Exported thermal energy
PERE [MJ] 1,17E+04 1,35E+02 3,75E+02 6,57E+02 1,36E+01 0,00E+00 4,08E+02 -4,67E+03
PERM [MJ] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
PERT [MJ] 1,17E+04 1,35E+02 3,75E+02 6,57E+02 1,36E+01 0,00E+00 4,08E+02 -4,67E+03
PENRE [MJ] 1,07E+05 2,02E+03 5,26E+03 9,82E+03 2,04E+02 0,00E+00 1,24E+03 -1,20E+04
PENRM [MJ] 1,21E+04 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
PENRT [MJ] 1,19E+05 1,35E+03 5,26E+03 9,82E+03 2,04E+02 0,00E+00 1,24E+03 -1,20E+04
RSF [MJ] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
NRSF [MJ] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
HWD [kg] 6,08E-05 3,41E-09 9,53E-09 1,66E-08 3,43E-10 0,00E+00 1,23E-08 -7,84E-07
NHWD [kg] 4,85E+02 3,03E-01 4,67E+00 1,47E+00 3,05E-02 0,00E+00 1,53E+02 -6,49E+00
RWD [kg] 9,85E-01 2,66E-03 9,83E-03 1,29E-02 2,68E-04 0,00E+00 4,17E-02 -4,67E-01
CRU [kg] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
MFR [kg] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
MER [kg] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00
EEE [MJ] 2,61E+02 0,00E+00 4,75E+02 0,00E+00 0,00E+00 0,00E+00 2,36E+03 0,00E+00
EET [MJ] 6,07E+02 0,00E+00 1,11E+03 0,00E+00 0,00E+00 0,00E+00 5,48E+03 0,00E+00
HWD = Hazardous waste disposed; NHWD = Non hazardous waste disposed; RWD = Radioactive waste disposed; CRU = Components for re-
Caption
use; MFR = Materials for recycling; MER = Materials for energy recovery; EEE = Exported electrical energy; EET = Exported thermal energy
The product considered in this study is installed The EPD does not contain any information on the
exclusively underground and is therefore not release of hazardous substances into soil and
relevant for indoor air. water, as the horizontal standards for the
relevant measurements are not available.
www.epddanmark.dk
Template version 2023.2
EN 15804
DS/EN 15804 + A2:2019 – ”Sustainability of construction works – Environmental product declarations –
Core rules for the product category of construction products”.
EN 15942
DS/EN 15942:2021 – ”Sustainability of construction works – Environmental product declarations –
Communication format business-to-business”.
EN 15941
DS/EN 15941:2024 – ”Sustainability of construction works - Data quality for environmental assessment
of products and construction work - Selection and use of data”.
ISO 14025
DS/EN ISO 14025:2010 – ”Environmental labels and declarations – Type III environmental declarations –
Principles and procedures”
ISO 14040
DS/EN ISO 14040:2020 – ”Environmental management – Life cycle assessment – Principles and
framework”
ISO 14044
DS/EN ISO 14044:2020 – ”Environmental management – Life cycle assessment – Requirements and
guidelines”