Microbiologics Lab Elte
CtRTEIEo PttERtHCt MATteIAL
(5
Certificate of Analysis: Lyophilized Microorganism Specification and Performance Upon Release
SPECIFICATIONS: RELEASE INFORMATION:
Product Name: Staphylococcus aureus subsp. aureus Quality ControlTechnologist: Margaret EWagener
Catalog Number: 0485 (CRM) (6) Release Date: 2023/08/28
|Lot Number: 485-1214**
Reference Number: ATCCO 6538TM*
Passage from Reference: 1
Expiration Date: 2025/07/3 1
Performance
Macroscopic Features: Medium:
|Medium to large, convex, circular, glistening, smooth, creamy, opaque, beta hemolytic - both SBAP
| light gold and darker gold colonies may be present. Asecond colony type maybe present a
white, circular, entire, low convex,and beta hemolytic.
Microscopic Features: Method:
Gram positive cOcci occurring singly, in pairs and in irregular clusters. Gram Stain (1)
ID System: MALDI-TOF (1)
See attached ID System results document.
Other Features/ Challenges: Results
(1)Catalase (3% Hydrogen Peroxide): positive
|(1) Coagulase (rabbit plasma -tube): positive
(1) Beta Lactamase (Cefinase Disk): negative Amanda Kuperus
Director of Quality Control
AUTHORIZED SIGNATURE
"Disclaimer: The last digits) of the liot number appearing on the product label and packing slip are merely a packaging event number. The lot number displayed
on this certificate is the actual base lot number.
Refer to the enclosed productinset forinstructions, Intended use and hazard/safety informatlon,
Individual products are traceable to a recognized culture collection.
(1) These tests are accredited to 1SO/NEC 17025.
ACCREDITED
TESTING CERT #2655.01
ATCC Licensed ()The ATCC Licensed Derivative Emblem, the ATCC Licensed Derivalive word mark and the ATcC calaog marks are trademarks of
Derivative ATCC. Microbiologics, Inc. is licensed to use these trademarks and to sell products derived from ATCC® cullures
ACCREDITED
REFERENCE MATERIAL PRODUCER
CERT 2655.02
(5) Microbiologics has determined each pellet of this relerence material to be sufficientty homogeneous for its intended use
(6) This produci has high confidence of identificaion
APROVADO
Antunes/Diretoria Técnica
© 2012 Microbiologics, Inc. AllRights Reserved. 200 Cooper Avenue North Saint Cloud, MN 56303 Page 1of Glória
Qualiagúá°
Bruker Daltonik MALDI Biotyper Classification Results
BRÚKER
Meaning of Score Values
Range Interpretation Symbols Color
2.00 - 3.00 High-confidence identification (t++) Green
1.70 1.99 Low-confidence identification (+) Yellow
0.00 -1.69 No Organism ldentification Possible (-) Red
Meaning of Consistency Categories (A - C)
Category| Interpretation
(A) High consistency: The best match is a high-confidence identification. The second-best match
is (1) a highconfidence identification in which the species is identical to the best match, (2) a
|low-confidence identification in which the species or genus is identical to the best match, or (3)
a non-identification.
(B) Low consistency: The requirements for high consistency are not met. The best match is a high
or low-confidence identification. The second-best match is (1) a high- or low-confidence
identification in which genus is identical to the best match or (2) a non-identification.
(C) No consistency: The requirements for high or low consistency are not met.
Run Creation DateTime: 2023-08-15T12:32:11.277 mhs
Applied MSP Library(ies): BDAL, Mycobacteria Library (bead method), Filamentous Fungi Library
Sample Name Sample ID Organism (best match) Score Value
A11 (+++) (A) 485-1214 Staphylococcus aureus 2.47
Comments:
NIA
APROVADO
Glória Antunes/Diretoria Técnica
Qualiágua