Installing RSView32 Runtime
The steps below explain how to install RSView32 software and user’s
guides from a CD–ROM to your computer. If you choose not to
install the user’s guides, you can view them from the CD.
Installing RSView32 Runtime on Windows
Server 2003, Windows XP, Windows 2000 and
Windows Vista
As part of the installation process, RSView32 Runtime creates
program folders and modifies registry entries. To make these
modifications, the currently–logged–in user must have administrative
rights on the computer on which RSView32 Runtime is installed.
Installing RSView32 Runtime
Follow these instructions to install RSView32.
To install RSView32 Runtime:
1. Close all open Windows programs.
2. Place the RSView32 CD–ROM into your CD–ROM drive. The
CD should start running automatically.
If the CD does not start automatically, run D:\Setup.exe where D
is the drive containing the CD.
3. In the RSView32 window, click the button beside Install RSView32
Runtime.
4. Follow the on–screen instructions.
5. During installation, you will be prompted to activate RSView32
Runtime. If activation is present from an earlier version of
RSView32 Runtime, click Next.
1–4 RSView32 Runtime User’s Guide
If you removed the activation or if you are installing RSView32
Runtime for the first time, insert the Activation disk in the diskette
drive and click Activate. For details about activation, see
“Activating RSView32 Runtime” on page 1-5.
6. When installation is complete, restart Windows. If you choose not
to restart Windows now, be sure to restart it before running
RSView32 Runtime for the first time.
If you plan to use RSView32 as an OPC server, you must configure
Microsoft® Distributed COM (DCOM). For instructions see the
RSView32 Help.
Installation summary
The default installation does the following:
installs RSView32 Runtime in the folder \Program Files\Rockwell
Software\RSView
adds a Rockwell Software\RSView32 folder to your list of
programs. This folder contains the shortcut for RSView32
Runtime
Ordering RSView32 Runtime on disks
RSView32 Runtime is available on 3.5–inch disks. To order disks,
contact your local authorized Allen–Bradley® distributor or your local
Allen–Bradley sales office.
Activating RSView32 Runtime
Rockwell Software Inc. uses activation files to activate its Windows–
based software packages. You can activate RSView32 Runtime by
using FactoryTalk Activation software to download and transfer
activation files.
Installing RSView32 Runtime 1–5
FactoryTalk® Activation
FactoryTalk Activation provides a secure, software-based system for
activating Rockwell Software products and managing software
activation files. With FactoryTalk Activation, there is no need for a
physical “master disk” or any physical media; instead, activation files
are generated and distributed electronically.
Important: EvRSI activation is replaced by FactoryTalk® Activation in this release.
If you are using EvRSI activation, please contact your local Rockwell Automation Sales
office or Technical Support for information on migrating your activations to Facto-
ryTalk® Activation. For Rockwell Automation Technical Support in the U.S. call (440
)646-3434. Outside the U.S. see http://www.rockwellautomation.com/locations/.
Finding more information about FactoryTalk
Activation
You can find detailed information, instructions, and troubleshooting
tips in the FactoryTalk Activation Help.
After installing and launching the FactoryTalk Activation software,
click Help or Learn More . . . to open FactoryTalk Activation Help.
Using the FactoryTalk Activation Manager
The FactoryTalk Activation tool is used to obtain the activation files
needed to activate your software. It can also be used to borrow
activations from servers having available activations, return activations
back to servers, re-host activations, etc.
To open the FactoryTalk Activation Manager:
On the Windows Start menu, click Programs > Rockwell Software >
FactoryTalk Activation > FactoryTalk Activation Manager.
To use the FactoryTalk Activation Manager:
1. In the FactoryTalk Activation Manager, click the Home tab then
click Get New Activations, or you may click Manage Activations
tab, then click Get New Activations.
2. Select the Activation Method to be used.
To provide the software’s Serial Number and Product Key, identify
the activation server’s Host ID, and download activation files,
follow the instructions in the manager.
1–6 RSView32 Runtime User’s Guide
3. Save the activation file or files.
Activation files must have a .lic extension. You can save the files to
the default location:
On Windows 2003 and Windows XP the default location for
FactoryTalk activation files is:.C:\Documents and Settings\All
Users\Shared Documents\Rockwell Automation\Activations
On Windows 7 Professional and Windows Vista the default
location for FactoryTalk activation files
is:C:\Users\Public\Documents\Rockwell
Automation\Activations"
For details, click Help in the top left corner of the page.
Protecting activation files
Activation files are simple text files that must have a .lic extension. The
activation key for RSView32 is called RSVMSGR.PRO.
As long as the .lic extension is retained, you can copy or rename an
activation file without harming it. However, tampering with text inside
the activation file can disable your Rockwell Software products.
If an activation file is damaged or deleted, contact Rockwell
Automation Technical Support.
For safekeeping, keep an original set of your activation files on backup
media. Use descriptive names for the files, so that you can identify them
later, and copy them back to the appropriate computers.
Activation files are locked to the Host IDs of the computers (or
dongles) that need them. Activation will fail for Rockwell Software
products on a computer where the specified Host ID is not recognized
by the activation file.
Installing RSView32 Runtime 1–7
Using borrowed activations
RSView32 supports borrowed activations for development computers.
A borrowed activation is retrieved from a pool of available activations
on the activation server, and expires after a specified length of time.
Once a borrowed activation is checked out to a particular computer,
the computer can disconnect from the network. When the time limit
expires, the associated software on the computer is no longer activated,
and the activation automatically becomes available again from the
server’s activation pool. A borrowed activation can also be returned to
the activation server manually before the time limit expires.
To borrow activations from a server:
1. Connect your computer to the network where the activation server
is located.
2. Run the FactoryTalk Activation Manager and then click the
Manager Activations tab.
3. Click the Manage Activations tab, and then click Borrow
Activations tab.To borrow a single activation, click the checkbox
that corresponds to the activation you want to borrow, and then
click Set Borrow Term. To borrow more than one activation, click
additional checkboxes for the activations you want to borrow and
then click Borrow. If you do not see the activations you want to
borrow, click I Don’t See My Activation Here. The Activations
in gray may not be selected as they are already borrowed by your
computer.
4. In the Set Borrow Term window, set the time of the return by
entering a calendar date, net number of days, or approximate hours
(shift). The default Calendar date is the maximum borrow term for
the activation or group of activations.
To return a borrowed activation before it expires:
1. Connect to the network and run the FactoryTalk Activation
Manager.
2. On the Manage Activations tab, click Return Activations, select
the borrowed activations you want to return.
3. Click the Return Activations button.
1–8 RSView32 Runtime User’s Guide
To open the Activation Help:
To open FactoryTalk Activation Help. Open FactoryTalk Activation Manager,
click Help or Learn More . . .
FactoryTalk® Activation Grace Period
FactoryTalk provides customers with access to critical software
components for a grace period of 7 days regardless of availability of
valid activations. When a product is successfully activated, all grace
period records will be cleared and the product will proceed with valid
activations.
During the grace period, FactoryTalk Activation will display a
warning message and log a diagnostic warning message to
FactoryTalk® Diagnostics every four hours if no valid activation key
is detected.
Once the grace period expires, RSView32 Runtime will enter demo
mode. However, until RSView32 is restarted, it will continue to run
as in the grace period.
RSView32 Personalized version can be successfully activated with
both RSView32 Personalized activations and RSView32 Protected
activations.
Uninstalling RSView32 Runtime
To uninstall RSView32 Runtime, use the Windows Control Panel.
To uninstall RSView32 Runtime:
1. Click the Windows Start button, point to Settings, and then click
Control Panel.
2. Double-click Add/Remove Programs, select RSView32 7.60.00,
and click Add/Remove.
3. Follow the on–screen instructions.
Installing RSView32 Runtime 1–9
4. When the Uninstall program is finished, restart Windows.
1–10 RSView32 Runtime User’s Guide
2
Chapter
Running a project
This chapter outlines:
the steps for setting up and running your project
how to add files to a project
how to stop a project
Setting up and running your project
Once you have installed RSView32™ Runtime on the target computer,
you are ready to set up and run the project you have created in
RSView32 Works.
Summary of steps
1. Move the project to the target computer.
2. If the target computer is configured for a different locale than the
development computer, specify time, date, and number formats.
3. Start RSView32 Runtime.
4. Open the project.
5. Set up the channels, OPC® server, or DDE server.
6. If applicable, change the path for any files that are outside of the
project directory.
7. Run the project.
Each of these steps is discussed in detail on the following pages.
2–1
Step 1 – Moving the project
If your project will be running on a different computer than it was
developed on, you must move the project using an external tool such
as Windows® Explorer, My Computer, or the File Manager. Be sure
you move all files referenced in your project, including any files
outside of the project directory.
You do not have to move the project to the same directory in which it
was created. When you move a project from one computer to another,
RSView32 Runtime automatically changes the project directory’s paths
to the drive and directory the project has been moved to. If your
project references files outside of the project directory, update the
path to these files in the Project Paths dialog box. See “Step 6 –
Changing the path to files outside the project directory” on page 2-7.
To move your project:
1. In Windows Explorer, My Computer, or File Manager, move or
copy the project folder to the target location.
2. Move or copy any folders or files outside the project folder to the
target location.
Step 2 – Specifying time, date, and number formats
Skip this step unless the target computer is configured for a different
locale than the development computer, and the new locale uses
different time, date, or number formats.
Use the Windows Control Panel to specify the formats. You can also
change these formats after the project is running, but you must close
and restart the project for the changes to take effect.
1. Click the Windows Start button, select Settings, and then click
Control Panel.
2. Double-click Regional Settings or Regional Options.
2–2 RSView32 Runtime User’s Guide
3. Select the language or locale whose settings you want to use.
4. Verify or customize the settings on the Number, Time, and Date
tabs.
5. Click OK.
For more information, see your Windows documentation.
Step 3 – Starting RSView32 Runtime
You can start RSView32 Runtime manually, or you can set up
RSView32 Runtime to start automatically when Windows starts.
Starting RSView32 Runtime manually
To start RSView32 Runtime in Windows 2000
Click the Windows Start button, select Programs, Rockwell
Software, RSView32, and then click RSView32 Runtime.
To start RSView32 Runtime in Windows Server 2003 and
Windows XP
Click the Windows Start button, select All Programs, Rockwell
Software, RSView32, and then click RSView32 Runtime.
Starting RSView32 Runtime automatically
To automatically start RSView32 Runtime each time Windows starts,
include an RSView32 Runtime shortcut in the Windows Startup
folder. You can also open a project when Windows starts.
To add RSView32 to the StartUp folder in Windows 2000
1. Click the Windows Start button, select Settings, and then click
“Taskbar & Start Menu.”
2. In the Taskbar and Start Menu Properties dialog box, click the
Advanced tab.
3. Click Add. The Create Shortcut wizard opens.
Running a project 2–3
4. To start RSView Works when Windows starts, browse to the
location of the RSV32.exe file, and then click the file name.
The path is \Program Files\Rockwell
Software\RSView\RSV32.exe.
5. To start RSView Works and open a project when Windows starts,
specify the path to RSView32 and to the project. For example, to
specify a project called Norm’s Bakery, type:
“C:\Program Files\Rockwell Software\RSView\RSV32.exe”
“C:\Program Files\Rockwell Software\Samples\Norm’s
Bakery\Norm’s Bakery.rsv”
If the path contains spaces, you must enclose it in double quotes.
6. Click OK, and then click Next.
7. In the Select Program Folder dialog box, select the Startup folder,
and then click Next.
8. Specify a name for the shortcut (for example, RSView32).
9. Click Finish, and then click OK.
For more information, see your Windows documentation.
To add RSView32 to the StartUp folder in Windows Server
2003, Windows XP and Windows Vista
1. Click the Windows Start button and select All Programs.
2. Right-click the Startup folder and select Open.
3. Browse to the location of the RSV32.exe file.
The path is \Program Files\Rockwell
Software\RSView\RSV32.exe.
4. Right-click the file name and select Create Shortcut. The shortcut
will be created in the same location as the RSV32.exe file.
5. Drag the shortcut into the Startup folder.
For more information, see your Windows documentation.
2–4 RSView32 Runtime User’s Guide
Step 4 – Opening the project
To open a project:
1. In the RSView32 Runtime window, click Open on the File menu.
2. In the Open dialog box, locate the project, click the project’s .rsv
file (for example, Norm’s Bakery.rsv), and then click Open.
Using the Runtime Project Manager
. . . any related
components
developed in
RSView32 Works
are listed here. To
run a component,
double-click it.
When you select an
icon here . . .
With the Runtime Project Manager you can:
edit channels, nodes, user accounts, and data log paths—to open
an editor, double–click the editor’s icon
view activity and alarm logs—to open the viewers, double–click
the Activity Log Viewer and the Alarm Log Viewer icons
Running a project 2–5
open the command line to manually enter RSView32 commands—
to open the command line, double–click the Command Line icon
run individual project components—to run a component, select
the icon for the editor that created the component, and then
double–click the component name
run a project—for details about running a project, see “Step 7 –
Running the project” on page 2-9
Step 5 – Setting up the channel, OPC server, or DDE
server
Before you can run a project, you must load and configure drivers for
the programmable controllers or servers that your project was
configured to use.
Connecting to programmable controllers
using direct drivers
To connect to most Allen–Bradley® devices, install and load RSLinx®
and install the driver required by your RSView32 project.
To communicate with SoftLogix™ 5 programmable controllers, you
must use an RSLinx driver.
IMPORTANT You must use the version of RSLinx that came with your RSView32
software. This version has been tested for compatibility with
RSView32. Other versions may not function correctly.
To select a different RSLinx driver for your project, use the Channel
editor.
For details about the RSLinx drivers, see the documentation
accompanying RSLinx. For details about the Channel editor, see
Chapter 2, Setting up direct driver communications, in the RSView32 User’s
Guide.
2–6 RSView32 Runtime User’s Guide
Connecting to OPC servers and DDE servers
To connect to a wide range of local and remote devices, install and
configure the appropriate OPC or DDE server. For details about
configuring the server, see your server documentation.
To change the OPC node’s server name and access path or the
application and topic name for the DDE server your project will use,
use the NodeSwitch command or use the Node editor.
For details about the NodeSwitch command, see Appendix A,
RSView32 commands, or see Help. For details about the Node editor,
see Chapter 3, Setting up OPC and DDE communications, in the
RSView32 User’s Guide.
Step 6 – Changing the path to files outside the
project directory
If your project references files outside of the project directory and the
path to these files has changed (for example, the drive letter has
changed), use the Project Paths dialog box to update the path.
For example, imagine your project directory is C:\Norm’s Bakery but
you have stored graphic files in C:\Gfx. You move your project from
C:\ to D:\. The paths to the files in \Norm’s Bakery are automatically
updated, but the path to \Gfx is not—you must update the path in the
Project Paths dialog box.
To change the path:
1. With the Project Manager active, click Project on the menu bar,
and then click Project Paths.
Running a project 2–7
2. Click the Application Paths tab.
3. In the Name field, select the editor that was used to create the
component.
Any components associated with the editor are displayed in the
Components field.
4. In the Default Path field, type the new path or click Browse to
select the new path.
5. Click Apply Default Path.
The components are updated to the new path.
6. Click OK.
2–8 RSView32 Runtime User’s Guide
Step 7 – Running the project
You can run the project manually or you can set up the project to run
automatically when Windows starts.
Running a project manually
In the Project Manager, click Run Project.
Click this button to
run a project.
Running a project automatically
To automatically start RSView32 Runtime and run a project each time
Windows starts, include an RSView32 Runtime shortcut in the
Windows Startup folder, as described on page 2-3.
Running a project 2–9
Adding files to a project
You can add new files to a project any time by copying or moving the
physical file to the target computer and then adding the file’s name to
the Project Manager.
To add files:
1. In Windows Explorer, My Computer, or File Manager, copy or
move the file you want to add into the appropriate folder in the
project. For example, add a graphic display file to the Gfx folder.
2. In the RSView32 Project Manager, select the icon for the editor
that was used to create the file (for example, select the Data Log
icon for a data log model), right–click, and then click Copy
Existing Component into Project or click Create Shortcut to
Existing Component.
3. In the dialog box, locate the file that you moved, and then click
Open. The file name will be added to the right–pane of the Project
Manager.
2–10 RSView32 Runtime User’s Guide
Changing data logging paths
You can change the data logging paths at runtime. You can change the
primary and secondary paths for dBASE® IV data log models, and the
backup path for ODBC data log models. You cannot change the
ODBC database using RSView32 Runtime. After you change the
logging path you must stop and restart data logging for the changes to
take effect.
To edit the logging paths:
1. In the Project Manager, open the Data Log folder.
2. Open the Data Log Path editor.
3. Specify paths as described in “Specifying Logging Paths” in
Chapter 7, Configuring data logging, in the RSView32 User’s Guide.
You can also change logging paths at runtime using the DataLogPath
command. For details about the DataLogPath command, see
Appendix A, RSView32 commands, or see Help.
Stopping a project
To stop a project, do one of the following:
in the Project Manager, click the Stop Project button
on the command line, type ProjectStop
Running a project 2–11
When a project stops
When a project stops, the following occurs:
open displays and RSView32 components close
running data log models stop
running derived tag files stop
running event files stop
alarm monitoring stops
OPC/DDE (real-time) data server stops
If a shutdown macro has been specified in the Startup editor, the macro
runs once the above components have closed and stopped running.
2–12 RSView32 Runtime User’s Guide
3
Chapter
Using security
This chapter describes how to:
add, delete, or change users
log into a running project
change passwords
This chapter is applicable only for projects that use security.
Editing the users for a project
If your project has been set up with security, only users or groups of
users listed in the User Accounts editor can log in and out of the
project.
You can enter user names and passwords in the User Accounts editor,
or, if you are using Windows® Server 2003, Windows XP, Windows
2000, or Windows Vista, you can use the Windows user list instead of
creating a custom RSView32™ list. No matter which method you
choose to create the user list, you still have to assign security access to
the individual users.
To open the User Accounts editor:
1. In the Project Manager, open the System folder.
2. Open the User Accounts editor.
3–1
For details about the fields in the User Accounts editor, see
Chapter 10, Adding security, in the RSView32 User’s Guide.
Logging in at runtime
If you want users to log in, your project must include a way for users
to access the RSView32 Login dialog box.
One way is to create a button in RSView32 Works. When configuring
the button, use the Login command as the press action. When the
button is pressed, the RSView32 Login dialog box appears.A
To successfully log in, users must enter a name, and a password (if
defined), that exists in the User Accounts editor.
3–2 RSView32 Runtime User’s Guide