The DMP305X-TST-H is a high-performance monosilicon gauge pressure transmitter designed for industrial applications, utilizing advanced sensor and encapsulation technologies for mechanical and thermal isolation. It features a measuring range from 1kPa to 10MPa, with output options including 4-20mA and HART protocol, and is suitable for extreme chemical and mechanical environments. The device is compliant with various standards and offers customizable parameters for specific application needs.

Uploaded by

Marcelo Pellizza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views13 pages

DMP305X-TST-H (GP)

The DMP305X-TST-H is a high-performance monosilicon gauge pressure transmitter designed for industrial applications, utilizing advanced sensor and encapsulation technologies for mechanical and thermal isolation. It features a measuring range from 1kPa to 10MPa, with output options including 4-20mA and HART protocol, and is suitable for extreme chemical and mechanical environments. The device is compliant with various standards and offers customizable parameters for specific application needs.

Uploaded by

Marcelo Pellizza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

SENSING

TOMORROW DMP305X-TST-H monosilicon gauge pressure transmitter

Product introduction

Description

Industrial pressure transmitter

DMP305X monosilicon pressure transmitter is a high


performance pressure transmitter with international
leading technology meticulously designed by LEEG
instrument, using the world's most advanced
monosilicon pressure sensor technology and patent
encapsulation technology. Monosilicon pressure sensor
locates on the top of the metal body and stay away from
the medium interface to realizes mechanical isolation and
thermal isolation. Glass sintering sensor wire realizes high
strength electrical insulation of metal base and improves
the capability of flexibility of electronic circuit and transient
voltage resistance protection. All these original
encapsulation technologies enable DMP305X to easily
cope with extreme chemical occasion and mechanical
load, and own strong resistance to EMI, sufficient to
respond to the most rigorous industrial environment
applications, which are the genuine invisible instruments.

DMP305X-TST-H

Main parameters Field of application

Pressure types Gauge pressure Pressure


Measuring range 1kPa-10MPa, please refer to the
ordering information chapter

Output signal 4-20mA, 4-20mA+HART, customer Approvals

Reference ±0.075% URL, optional ±0.05%URL


accuracy

Measuring medium

The fluids which compatible with wetted parts

Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

2016.12.V1.0-1 www.leegsensor.com .1.


SENSING
TOMORROW DMP305X-TST-H monosilicon gauge pressure transmitter

Technical Specifications

Measuring range and limit

Nominal value Smallest calibratable span Lower range limit(LRL) Upper range limit(URL) Overload limit
6kPa 1kPa -6kPa 6kPa 25MPa
40kPa 2kPa -40kPa 40kPa 25MPa
250kPa 12.5kPa -100kPa 250kPa 25MPa
1MPa 50kPa -100kPa 1MPa 25MPa
3MPa 150kPa -0.1MPa 3MPa 25MPa
10MPa 500kPa -0.1MPa 10MPa 25MPa
The unit of the measuring range above can be converted into kg/cm²、 MPa and kPa, etc. Provide other measuring range
according to requirements. Adjust requirements: lower range value (LRV) and upper range value (URV) can be adjusted within
the scope of the upper and lower range limit, smallest calibratable span≤| URV - LRV |≤URL

Standard specifications and reference conditions Mounting position effects

Test standard: GB/T28474 / IEC60770; Zero based-calibration Apply to any position. Max value lower than 400Pa can be
span, Silicon oil filling, 316L stainless steel isolated corrected by zero clearing function.
diaphragm, 4-20mA analog output.

Vibration effects
Performance specifications

According to GB/T 1827.3/IEC61298-3 tests, <0.1% URL


The overall performance including but not limited to 【
reference accuracy 】,【environment temperature
effects】and other comprehensive error
Output signal
Typical accuracy: ±0.075%URL
Stability: ±0.2% URL/ year
4-20mA two wire. Customers can choose linear output or
square root output. Digital process variables
superimpose on 4-20mA signal and apply to any hosts
Reference accuracy
with HART protocol.

Standard and reference conditions, including linearity


(BFSL), hysteresis and repeatability. calibration Ambient temperature effects(Typical)
temperature: 20 ℃ ± 5 ℃
Linear TD≤10(Note1) ±0.075%URL Nominal value:
within the range -20-80℃ total impact ±(0.1+0.1TD)% URL
output 6kPa, 40kPa
accuracy 10<TD<20 ±0.0075TD% 250kPa, 1MPa
URL 3MPa, 10MPa
Note 1: TD is Turn down, TD=URL/ |URV-LRV|
Insulation resistance

≥ 20M Ω@, 100VDC


Power supply effects

Zero and span change should not be more than ± 0.005%


URL/V when power supply changes in 10.5/16.5-55VDC

Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

2016.12.V1.0 www.leegsensor.com .2.


SENSING
TOMORROW DMP305X-TST-H monosilicon gauge pressure transmitter

Technical Specifications

Damping time Power supply

Total damping time constant: equal to the sum of damping Item Operating conditions
time of amplifer and sensor capsule Standard/flame 10.5-55VDC
Damping time of amplifer: 0-100S adjustable proof
Diaphragm capsule (isolated diaphragm and silicon oil filling) HART protocol 16.5-55VDC, communication load
damping time: ≤0.2s resistance 250Ω
Startup after power off: ≤6S Load resistance 0-2119 Ω for working condition, 250-
Normal services after data recovery: ≤31S 600Ω for HART protocol
Transmission <1000m
Weight distance
Power ≤500mW@24VDC, 20.8mA
Net weight: about 1.56kg (without mounting brackets and consumption
process connection accessory)

Environment condition Power supply and load requirements

Items Operational condition


R (Ω) External load resistance
Working -40-85℃, integrated LCD display: -20-
2119
temperature 70℃
Storage -40-110℃, integrated LCD display: -
U-10.5
temperature 40-85℃ R=
0.021
Media Silicon oil filling: -40-120℃
temperature
600
Digital
Working humidity 5-100% RH@40℃
communication
Protection class IP67 250
range HART

Dangerous ExiaIICT4(GYB16.1962X)*
0
condition ExdIICT6(GYB16.1254X)* 10.5 16.5 23.8 55 Power supply
*Only for 4-20mA output voltage U(V)

EMC environment

NO. Test items Basic standards Test conditions Performance level


1 Radiated interference GB/T 9254/CISPR22 30MHz-1000MHz OK
2 Conducted interference (DC power port) GB/T 9254/CISPR22 0.15MHz-30MHz OK
3 Electrostatic discharge immunity test (ESD) GB/T 17626.2/IEC61000-4-2 4kV(Contact ),8kV(Air) B(Note2)
4 Immunity to radio frequency EM-fields GB/T 17626.3/IEC61000-4-3 10V/m(80MHz-1GHz) A(Note1)
5 Power frequency magnetic field Immunity GB/T 17626.8/IEC61000-4-8 30A/m A(Note1)
test
6 Electrical fast transient / Burst Immunity GB/T 17626.4/IEC61000-4-4 2kV(5/50ns,100kHz) B(Note2)
Test
7 Surge immunity requirements GB/T 17626.5/IEC61000-4-5 1kV(Line to line) B(Note2)
2kV(Line to ground)
(1.2us/50us)
8 Immunity to conducted disturbances GB/T 17626.6/IEC61000-4-6 3V(150kHz-80MHz) A(Note1)
induced by radio frequency fields
(Note 1)Performance level A: The preformance within the limits of normal technical specifications.
(Note 2)Performance level B: Temporary reduction or loss of functionality or preformance, it can restore itself. The actual
operating conditions, storage and data will not be changed.
Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

2016.12.V1.0 www.leegsensor.com .3.


SENSING
TOMORROW DMP305X-TST-H monosilicon gauge pressure transmitter

Menu function

Specific menu Measuring menu set

Transmission module type Mark State


URV Upper range value, 20mA
Output signal Local control Remote control LRV Lower range value, 4mA
4-20mA+HART LCD/3 buttons on body HART
4-20mA LCD/3 buttons on body - Damping time

Units Setting range


LCD display unit S 0-100

Display Details Analog output type


mode
PV Process variable shows on main screen, Parameters Output type
percentage and progress bar shows on
mA LINER Linearity
secondary screen
mA Square root
mA Current shows on main screen, percentage and
progress bar shows on secondary screen
Alarm signal
% Percentage shows on main screen, percentage
and progress bar shows on secondary screen
Parameters Alarm signal
ALARM NO None
Unit ALARM H 20.8mA
ALARM L 3.8mA

Unit Definition
kPa Kilopascal Fix output

MPa Megapascals
bar Bar Parameters Fix output value
psi Pounds per square inch FIX/C NO None
mmHg Millimetre(s) of mercury@0℃ 3.8000 3.8000mA
mmH2O Millimeter of water@4℃ 4.0000 4.0000mA

mH2O Meter of water@4℃ 8.0000 8.0000mA

inH2O Inches of water@4℃ 12.000 12.000mA

ftH2O Feet of water@4℃ 16.000 16.000mA

inHg Inches of mercury@0℃ 20.000 20.000mA

mHg Meter mercury column@0℃ 20.800 20.800mA

TORR Torr
mbar Millibar Quick menu

g/cm2 Gram per square centimeter


kg/cm2 Kilogram per square centimeter Parameter Instruction
Pa PA Set current output to zero value,
PV=0 used to correct the error cased by
ATM Standard atmospheric pressure
static pressure and installation.
mm Millimeter(Note1)
Zero adjustment 4mA re-range with pressure
m Meter(Note1)
Span adjustment 20mA re-range with pressure
Note1: length unit need mark medium density
Restore factory setting Restore backup data when error

Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

2016.12.V1.0 www.leegsensor.com .4.


SENSING
TOMORROW DMP305X-TST-H monosilicon gauge pressure transmitter

Product selection instruction

Sensor select instruction Electrical connection

Code Nominal Description Code Item Description


value T1 Electrical Aluminum-alloy terminal,2 cable entry
H602G 6kPa Range -6kPa-6kPa, connection M20*1.5(F), red body, white cover
smallest calibratable span 1kPa R1 Cable entry Waterproof connector M20*1.5 one
H403G 40kPa Range -40kPa-40kPa, protector side , blind plug another side, PVC
material,6-8mm diameter cable only,
smallest calibratable span 2kPa
IP67
H254G 250kPa Range -100kPa-250kPa,
R2 Flame proof, 1/2 NPT(F) one side,
smallest calibratable span 12.5kPa
blind plug another side, stainless steel
H105G 1MPa Range -0.1MPa-1MPa, material, 6-8mm diameter cable only,
smallest calibratable span 50kPa IP67
H305G 3MPa Range -0.1MPa-3MPa, R3 Flame proof, M20X1.5(F) one side,
smallest calibratable span 150kPa blind plug another side, stainless steel
H106G 10MPa Range -0.1MPa-10MPa, material, 6-8mm diameter cable only,
smallest calibratable span 500kPa IP67
Adjust requirements: lower range value (LRV) and upper
range value (URV) can be adjusted within the scope of the
upper and lower range limit, smallest calibratable span≤|
Housing(T1)
URV - LRV |≤URL

Code Position Description


S Diaphragm Stainless steel, SUS316L
H material Hastelloy C
S Fluid filling Silicon oil, process temperature: -
45-205℃
D Fluorocarbon oil, process
Standard cable entry protective adaptor(R1)
temperature: -45-160℃
F Sensor seal Stainless steel welding seal

Diaphragm(S/H)

Flame proof cable entry protective adaptor(R2/R3)

Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

2016.12.V1.0 www.leegsensor.com .5.


SENSING
TOMORROW DMP305X-TST-H monosilicon gauge pressure transmitter

Product selection instruction

Transmission module G08 G1/4(M), Φ3 pressure lead hole,


GB/T7307, ISO228, DIN16288,
BS2779, seal reference DIN3852-
Code Items Description
E(back-end seal)
F Output 4-20mA two wire, power supply: 10.5-
R01 1/2-14NPT(M), Φ3 pressure lead
signal 55VDC
hole, GB/T12716, ANSI/ASME
H 4-20mA+HART two wire,power B1.20.1
supply: 16.5-55VDC
R02 1/4-18NPT(M), Φ3 pressure lead
A Display Without display hole, GB/T12716, ANSI/ASME
C With LCD display B1.20.1
R03 1/2-14NPT(F), GB/T12716, ANSI/
ASME B1.20.1

Display module(C)
R04 1/4-18NPT(F), GB/T12716, ANSI/
ASME B1.20.1

Brackets

Code Items Instruction


B4 Fixed U-shaped bracket, 2" pipe, apply to T-
mounting structure
Terminals

Fixed mounting bracket (B4)(DMP305X-TST-H)

Process connection select instruction

Code Items Description


6 Material Stainless steel, SUS316
M01 Specifications M20*1.5(M), Φ3 pressure lead hole,
GB/T193-2003, ISO261
G01 G1/2(M), Φ3 pressure lead hole,
EN837
G02 G1/4(M), Φ3 pressure lead hole,
EN837

Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

2016.12.V1.0 www.leegsensor.com .6.


SENSING
TOMORROW DMP305X-TST-H monosilicon gauge pressure transmitter

Product drawing and dimension

Drawing and dimension of DMP305X-TST-H with display(C) ( unit: mm)

131 110

175
132
20

M20X1.5
48

Drawing and dimension of DMP305X-TST-H without display(A) ( unit: mm)

131 133
175
132
20

M20X1.5
48

Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

2016.12.V1.0 www.leegsensor.com .7.


SENSING
TOMORROW DMP305X-TST-H monosilicon gauge pressure transmitter

Product drawing and dimension

Fixed mounting braket installation dimension of DMP305X-TST-H (B4) ( unit: mm)

131 131
176
119

119

160
R32.50

1
R2

26
111

146

Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

2016.12.V1.0 www.leegsensor.com .8.


SENSING
TOMORROW DMP305X-TST-H monosilicon gauge pressure transmitter

Product drawing and dimension


尺寸图

Process connection(M01) (unit: mm) Process connection(G01) (unit: mm)


3 20

20
2

2
5

3
5
17.5
17.5
M20X1.5
GB-T193-2003 G1/2
EN837

Process connection(G02) (unit: mm) Process connection(G08) (unit: mm)


2 13

14
12
2

5 18.9
9.5 G1/4
DIN3852-E
G1/4
EN837

Process connection(R01) (unit: mm) Process connection(R02) (unit: mm)


19

16

1/2NPT 1/4NPT
ANSI/ASME 1.20.1 ANSI/ASME 1.20.1

Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

2016.12.V1.0 www.leegsensor.com .9.


SENSING
TOMORROW DMP305X-TST-H monosilicon gauge pressure transmitter

Product drawing and dimension

过程连接(R03)(单位:mm)
Process connection(R03) (unit: mm) 过程连接(R04)(单位:mm)
Process connection(R04) (unit: mm)

21
16

14

15

12
1/2NPT 1/4NPT
ANSI/ASME B1.20.1 ASNI/ASME B1.20.1

Heat exchange connector(N1) (unit: mm) Heat exchange connector(N2)(unit: mm)

M20X1.5 31
M20X1.5
22

21
208

65
121
10 19

10
3

M20X1.5
14

M20X1.5

Welding adaptor(Z1) (unit: mm) Welding adaptor(Z2) (unit: mm)

30 30
M20X1.5 G1/2
20

20
40

40

6 6

Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

2016.12.V1.0 www.leegsensor.com . 10 .
SENSING
TOMORROW DMP305X-TST-H monosilicon gauge pressure transmitter

Ordering information chapter

Item Parameters Code Instruction (*) fast delivery available

Model DMP305X-TST Monosilicon gauge pressure transmitter


Sensor Separator - Detailed specifications as following
Pressure H602G Nominal value(URL): 6kPa
range code H403G Nominal value(URL): 40kPa
H254G Nominal value(URL): 250kPa *
H105G Nominal value(URL): 1MPa *
H305G Nominal value(URL): 3MPa *
H106G Nominal value(URL): 10MPa *
Diaphragm S SUS316L
material
H Hastelloy C

Isolated S Silicon oil, process temperature: -45-205℃


fluid filling
D Fluorocarbon oil, process temperature: -45-160℃
Sensor seal F Stainless steel welding seal
Electrical Separator - Detailed specifications as following
connection
Electrical T1 Aluminum-alloy terminal, 2 cable entry M20*1.5(F), red *
connection body, white cover
Cable entry R1 Waterproof connector M20*1.5 one side, blind plug another *
protector side, PVC material, 6-8mm diameter cable only, IP67
R2 Flame proof, 1/2 NPT(F) one side, blind plug another side,
stainless steel material, 6-8mm diameter cable only, IP67
R3 Flame proof, M20*1.5(F) one side, blind plug another side,
stainless steel material, 6-8mm diameter cable only, IP67
Output Separator - Detailed specifications as following
Output F 4-20mA two wire, power supply: 10.5-55VDC
signal
H 4-20mA+HART two wire, power supply: 16.5-55VDC *
Display C LCD display *
A Without LCD display

Process Separator - Detailed specifications as following


connection
Material 6 SUS316 *
Specification M01 M20*1.5 (M), Φ3 pressure lead hole, GB/T193-2003, *
ISO261
G01 G1/2 (M), Φ3 pressure lead hole, GB/T7307, ISO228, *
DIN16288, BS2779
G02 G1/4(M), Φ3 pressure lead hole, EN837
G08 G1/4(M), Φ3 pressure lead hole, GB/T7307, ISO228,
DIN16288, BS2779, seal refers to DIN3852-E (back-end
seal)

Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

2016.12.V1.0 www.leegsensor.com . 11 .
SENSING
TOMORROW DMP305X-TST-H monosilicon gauge pressure transmitter

Ordering information chapter

R01 1/2 -14NPT(M), Φ3 pressure lead hole, GB/T12716, *


ANSI/ASME B1.20.1

R02 1/4 -18NPT(M), Φ3 pressure lead hole, GB/T12716,


ANSI/ASME B1.20.1

R03 1/2 -14NPT(F), GB/T12716, ANSI/ASME B1.20.1

R04 1/4 -18NPT(F), GB/T12716, ANSI/ASME B1.20.1

Additional Separator - Detailed specifications as following


options
Fixed /B4 U-shaped bracket, 2" pipe, apply to T-structure *
mounting
accessory

Process /N1 Heat exchange connector, M20*1.5 (F) change to *


connection M20*1.5(M), SUS304(Condenser pipe)
mounting
accessory
/N2 Heat exchange connector, M20*1.5 (F) change to *
M20*1.5(M), SUS304(Cooling fin)
Process /Z1 Welding adaptor, M20*1.5(F), SUS304 *
connection
accessory /Z2 Welding adaptor, G1/2(F), SUS304 *
Display /D1 According to your requirements
mode
Calibration /Q1 Calibration report provided by our company
report
Approvals /E1 Flame proof certificate, ExdIICT6, NEPSI *
(multiple)
/I1 Intrinsic safety certificate, ExiaIICT4, NEPSI *
/F3 CE certificate *
Wetted parts /G1 Ungrease treatment
treatment
/G2 Electropolishing treatment

Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

2016.12.V1.0 www.leegsensor.com . 12 .
SENSING
TOMORROW DMP305X-TST-H monosilicon gauge pressure transmitter

Factory settings and parameters

Item Menu mark Factory setting value Item Menu mark Factory setting value
Tag position None 0(No specific settings) Damping value DAMP 0(No specific settings)
Analog output type mA Liner 4mA Lower range According to the order
LRV
Display mode DISP PV value

Alarm signal ALARM No 20mA Upper range URV According to the order
value
Process unit U According to the order

Approvals

Factory certificate CE

Certification organization Intertek Certificate organization ISET


Quality management system ISO9001-2008 License scope DMP305X series pressure/
Design and production of differential pressure transmitter
Scope of certification
pressure transmitter Mark EU
Registration number 110804039 EMC instruction 2014/30/EU
Standard AC/0100708

Intrinsic safety certificate Registration number IT041353LG161207

Certification NEPSI Flame proof certificate


organization name
License range DMP305X series pressure/
Certificate organization NEPSI
differential pressure transmitter
License scope DMP305X series pressure/
Explosion-proof mark ExiaIICT4
differential pressure transmitter
Ambient temperature -40-+60℃
Explosion-proof mark ExdIICT6
Medium maximum +120℃
Working environmental -25-+60℃
temperature
temperature
Registration number GYB16.1962X
Maximum medium +80℃
Intrinsically safe Maximum input voltage: 28VDC temperature
parameter Maximum input current: 100mA Registration number GYB16.1254X
description
Maximum input power: 0.7w
Maximum internal equivalent
parametersCi(uF): 0
Maximum internal equivalent
parametersLi(mH): 0.01 SENSING
TOMORROW

Shanghai LEEG Instruments Co.,Ltd


ADD:No.100 Duhui Road, Minhang District, Shanghai China
Postcode:201109
Tel: (86) 21-31261976
Fax:(86) 21-31261975
E-mail:[email protected] [email protected]
scan & follow LEEG wechat check website for more info Web:www.leegsensor.com

Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

2016.12.V1.0 www.leegsensor.com . 13 .

You might also like