0% found this document useful (0 votes)
342 views1 page

CEDD Standard Drawing No. C2104-1 Tree Ring (Sheet 1 of 2)

The document outlines specifications for sprayed concrete used in tree rings, including thickness and mesh reinforcement details. It provides a diagrammatic representation of the finished slope profile and drainage channel, as well as minimum inner diameter requirements for tree rings based on tree size. The drawing is part of a civil engineering project and includes a reference to a previous drawing and the date of creation.

Uploaded by

linsi.puti
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
342 views1 page

CEDD Standard Drawing No. C2104-1 Tree Ring (Sheet 1 of 2)

The document outlines specifications for sprayed concrete used in tree rings, including thickness and mesh reinforcement details. It provides a diagrammatic representation of the finished slope profile and drainage channel, as well as minimum inner diameter requirements for tree rings based on tree size. The drawing is part of a civil engineering project and includes a reference to a previous drawing and the date of creation.

Uploaded by

linsi.puti
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

SPRAYED CONCRETE

(THICKNESS TO BE
SPECIFIED BY THE ENGINEER)

FINISHED SLOPE PROFILE

MESH REINFORCEMENT
EXISTING TREE
(DIAGRAMMATIC)
25 x 25
CHAMFER
50
10
0

EDGE TO BE SLIGHTLY
50

ROUNDED OFF
CO
M

V
IN

ER
IM
U

UPSTAND FORMED BY
M
IN

SPRAYED CONCRETE
N

(SEE PLAN OF TREE RING)


ER
D
(S

IA
E

M
E

ET
T
A

50
ER
B
L

O
E

10
1

TH

0
)

E
TR
EE

DRAINAGE CHANNEL
R

(SEE SECTION A-A)


IN
G

50
CO

25 x 25
V

CHAMFER
ER

SECTION OF TREE RING


SCALE 1 : 10

TABLE 1 : MINIMUM INNER DIAMETER OF TREE RING

TREE SIZE
TREE RING INNER DIAMETER (mm)
( SEE NOTE 8 )

SMALL TREE TRUNK DIAMETER AT GROUND LEVEL PLUS 600

MEDIUM TREE TRUNK DIAMETER AT GROUND LEVEL PLUS 800

LARGE TREE TRUNK DIAMETER AT GROUND LEVEL PLUS 1000

- FORMER DRG. NO. C2104F. Original Signed 03.2015


REF. REVISION SIGNATURE DATE

CIVIL ENGINEERING AND


TREE RING DEVELOPMENT DEPARTMENT

SCALE AS SHOWN DRAWING NO.


(SHEET 1 OF 2) DATE JAN 1991 C2104 / 1