0% found this document useful (0 votes)
122 views144 pages

PACKAGE UNITS - JUDICIAL INSTITUTION BUILDING - MINISTRY Technical Submittal.

The document is a technical submittal for the Judicial Institution Building project by the Ministry of Justice, detailing the involvement of SKM Air Conditioning LLC as the contractor and Altorath International as the consultant. It includes sections such as company profile, trade license, compliance statement, and technical data sheets. The document serves as an official record and does not require a stamp or signature.

Uploaded by

mahmoud238966
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
122 views144 pages

PACKAGE UNITS - JUDICIAL INSTITUTION BUILDING - MINISTRY Technical Submittal.

The document is a technical submittal for the Judicial Institution Building project by the Ministry of Justice, detailing the involvement of SKM Air Conditioning LLC as the contractor and Altorath International as the consultant. It includes sections such as company profile, trade license, compliance statement, and technical data sheets. The document serves as an official record and does not require a stamp or signature.

Uploaded by

mahmoud238966
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 144

PROJECT: JUDICIAL INSTITUTION BUILDING- MINISTRY

OF JUSTICE

Built in the Gulf … for the world

SKM- TECHNICAL SUBMITTAL – PACKAGE UNIT/SPLIT UNITS

CLIENT NAME
M/S. MINISTRY OF ENERGY & INFRASTRUCTURE.

CONTRACTOR NAME
M/S. Al AUSUS AL ARBAA GEN CONT .CO .L.L.C.

CONSULTANT NAME
M/S. ALTORATH INTERNATIONAL.

Revision: Original Issue


Prepared By: Eng. Bilel KACEM
21th Mai 2024
INDEX
• COMPANY PROFILE
• TRADE LICENCE
• CERTIFICATES
• COMPLIANCE STATEMENT
• TECHNICAL DATA SHEET

• PRODUCT CATALOUGES
• PROJECT REFERENCE LIST
• PREVIOUS PROJECT APPROVAL
• CERTIFICATE OF ORIGIN
• DRAFT WARRANTY CERTIFICATE
� .
��H�
..
::111 ,..

.. ......, �

Contact us
. . . . s:•;½ .
f:f9 C>ttiCt 8►1
AIR CONDITIONING E QUIPMENT

SKM Offices

[!] ,,,,,[!] r (!) (!)'


I
.. . .
. .
I '

t ••.

•(!)

For SKM Regional Offices & Distributors


visit: www.skmaircon.com

SKM.CPR-EN.2021
TRADE LICENCE
‫ﺭﺧﺼﺔ ﺻﻨﺎﻋﻴﺔ‬
‫‪Industrial License‬‬
‫‪License Details‬‬ ‫ﺗﻔﺎﺻﻴﻞ ﺍﻟﺮﺧﺼﺔ‬

‫‪Issue Date‬‬ ‫‪16-01-1975‬‬ ‫‪ License No.‬ﺗﺎﺭﻳﺦ ﺍﻹﺻﺪﺍﺭ‬ ‫‪341‬‬ ‫ﺭﻗﻢ ﺍﻟﺮﺧﺼﺔ‬

‫‪Expiry Date‬‬ ‫‪17-04-2025‬‬ ‫‪ Registration No.‬ﺗﺎﺭﻳﺦ ﺍﻹﻧﺘﻬﺎﺀ‬ ‫‪37171‬‬ ‫ﺭﻗﻢ ﺍﻟﺴﺠﻞ‬

‫ﺍﺱ‪.‬ﻛﻲ‪.‬ﺍﻡ ﻟﻠﺘﻜﻴﻴﻒ ﺫ ﻡ ﻡ‬ ‫ﺍﻻﺳﻢ ﺍﻟﺘﺠﺎﺭﻱ‬

‫‪Trade Name‬‬ ‫‪S.K.M AIR CONDITIONING LLC‬‬

‫‪Legal status‬‬ ‫‪Limited Liability Company‬‬ ‫ﺷﺮﻛﺔ ﺫﺍﺕ ﻣﺴﺆﻭﻟﻴﺔ ﻣﺤﺪﻭﺩﺓ‬ ‫ﺍﻟﺸﻜﻞ ﺍﻟﻘﺎﻧﻮﻧﻲ‬

‫‪License Members‬‬ ‫ﺃﻃﺮﺍﻑ ﺍﻟﺮﺧﺼﺔ‬

‫ﺍﻟﺤﺼﺺ‬ ‫ﺍﻟﺼﻔﺔ‬ ‫ﺭﻗﻢ ﺍﻟﻬﻮﻳﺔ ‪ /‬ﺍﻟﺠﻮﺍﺯ‬ ‫ﺍﻟﺠﻨﺴﻴﺔ‬ ‫ﺍﺳﻢ ﺍﻟﻤﺴﺘﺜﻤﺮ‬ ‫ﺭﻗﻢ ﺍﻟﻤﺴﺘﺜﻤﺮ‬

‫‪Shares‬‬ ‫‪Type‬‬ ‫‪ID \ Passport No‬‬ ‫‪Nationality‬‬ ‫‪Investor Name‬‬ ‫‪Investor No‬‬

‫ﺷﺮﻳﻚ‬ ‫ﺍﻟﻜﻮﻳﺖ‬ ‫ﻋﺒﺪﺍﻟﻌﺰﻳﺰ ﻣﺒﺎﺭﻙ ﻋﺒﺪﺍﻟﻌﺰﻳﺰﺻﺎﻟﺢ ﺍﻟﺤﺴﺎﻭﻯ‬


‫‪18.0 %‬‬ ‫‪784195985417088‬‬ ‫‪34819‬‬
‫‪Partner‬‬ ‫‪Kuwait‬‬ ‫‪ABDULAZIZ M A S ALHASAWI‬‬

‫ﺷﺮﻳﻚ‬ ‫ﺍﻟﻜﻮﻳﺖ‬ ‫ﻣﺒﺎﺭﻙ ﺳﻌﻮﺩ ﻋﺒﺪﺍﻟﻌﺰﻳﺰ ﺧﺎﻟﺪ ﺍﻟﺒﺸﺎﺭﻩ‬


‫‪53.0 %‬‬ ‫‪784197597406947‬‬ ‫‪24343‬‬
‫‪Partner‬‬ ‫‪Kuwait‬‬ ‫‪MUBARAK S A KH ALBESHARAH‬‬

‫ﺷﺮﻳﻚ‬ ‫ﺍﻹﻣﺎﺭﺍﺕ‬ ‫ﺍﻟﻬﻀﺎﺏ ﻟﻠﺘﺠﺎﺭﺓ ﺍﻟﻌﺎﻣﺔ ﺫ ﻡ ﻡ‬


‫‪10.0 %‬‬ ‫‪4803282‬‬
‫‪Partner‬‬ ‫‪UAE‬‬ ‫‪AL HIDHAB GEN.TR.LLC‬‬

‫ﺷﺮﻳﻚ‬ ‫ﺍﻟﻜﻮﻳﺖ‬ ‫ﺷﺮﻛﺔ ﺑﺸﺎﻳﺮ ﺍﻟﻤﺘﺤﺪﺓ ﺍﻟﻌﻘﺎﺭﻳﺔ‬


‫‪8.0 %‬‬ ‫‪4804599‬‬
‫‪Partner‬‬ ‫‪Kuwait‬‬ ‫‪BASHAIER UNITED REAL ESTATE‬‬

‫ﺷﺮﻳﻚ‬ ‫ﺍﻟﻜﻮﻳﺖ‬ ‫ﺧﻮﻟﻪ ﻣﺒﺎﺭﻙ ﻋﺒﺪﺍﻟﻌﺰﻳﺰ ﺻﺎﻟﺢ ﺍﻟﺤﺴﺎﻭﻯ‬


‫‪2.0 %‬‬ ‫‪784196263214726‬‬ ‫‪24332‬‬
‫‪Partner‬‬ ‫‪Kuwait‬‬ ‫‪KHAWLAH M A S ALHASAWI‬‬

‫ﺷﺮﻳﻚ‬ ‫ﺍﻟﻜﻮﻳﺖ‬ ‫ﺣﺒﻴﺒﻪ ﻣﺒﺎﺭﻙ ﻋﺒﺪﺍﻟﻌﺰﻳﺰ ﺻﺎﻟﺢ ﺍﻟﺤﺴﺎﻭﻯ‬


‫‪9.0 %‬‬ ‫‪784197025974037‬‬ ‫‪24328‬‬
‫‪Partner‬‬ ‫‪Kuwait‬‬ ‫‪HABIBAH M A S ALHASAWI‬‬

‫ﻋﺒﺪﺍﻟﻜﺮﻳﻢ ﺍﺑﺮﺍﻫﻴﻢ ﻋﺒﺪﺍﻟﻤﻠﻚ‪ ,‬ﻣﺒﺎﺭﻙ ﺳﻌﻮﺩ ﻋﺒﺪﺍﻟﻌﺰﻳﺰ ﺧﺎﻟﺪ ﺍﻟﺒﺸﺎﺭﻩ‪ ,‬ﻭﻟﻴﺪ ﺧﺎﻟﺪ ﻋﺒﺪﺍﻟﻠﻪ ﻣﺤﻤﺪ ﺍﻟﻤﺴﻔﺮ‬ ‫ﺍﻟﻤﺪﻳﺮ‬

‫ﺻﻨﺎﻋﺔ ﻭﺣﺪﺍﺕ ﺍﻟﺘﻜﻴﻴﻒ‪,‬ﺇﺻﻼﺡ ﻭﺻﻴﺎﻧﺔ ﻣﻜﻴﻔﺎﺕ ﺍﻟﻬﻮﺍﺀ ﻣﻌﺪﺍﺕ ﺍﻟﺘﺒﺮﻳﺪ ﻭﺗﻨﻘﻴﺔ ﺍﻟﻬﻮﺍﺀ‪,‬ﺻﻨﺎﻋﺔ ﻣﻌﺪﺍﺕ ﺗﻜﻴﻴﻒ ﺍﻟﻬﻮﺍﺀ‬
‫ﺃﻧﺸﻄﺔ ﺍﻟﺮﺧﺼﺔ‬
‫ﺍﻟﻤﺮﻛﺰﻱ‬

‫‪User Name‬‬ ‫‪53544‬‬ ‫ﺭﻗﻢ ﺍﻟﻤﺴﺘﺨﺪﻡ‬ ‫‪Printing Date‬‬ ‫‪15-04-2024‬‬ ‫ﺗﺎﺭﻳﺦ ﺍﻟﻄﺒﺎﻋﺔ‬
‫‪- This document is official. It doesn't need to be stamped or signed.‬‬ ‫‪ -‬ﻫﺬﻩ ﺍﻟﻮﺛﻴﻘﺔ ﺭﺳﻤﻴﺔ ﻭﻻ ﺗﺤﺘﺎﺝ ﻟﺨﺘﻢ ﺃﻭ ﺗﻮﻗﻴﻊ‪.‬‬
‫‪To view license details please visit SEDD web site: www.sedd.ae‬‬ ‫ﻟﻠﺘﺄﻛﺪ ﻣﻦ ﺻﺤﺔ ﺍﻟﺒﻴﺎﻧﺎﺕ ﻳﺮﺟﻰ ﺯﻳﺎﺭﺓ ﻣﻮﻗﻊ ﺍﻟﺪﺍﺋﺮﺓ‪www.sedd.ae :‬‬
‫‪- It is prohibited to distribute advertisements in public places and residential areas.‬‬ ‫‪ -‬ﻳﻤﻨﻊ ﺗﻮﺯﻳﻊ ﺍﻹﻋﻼﻧﺎﺕ ﻓﻲ ﺍﻷﻣﺎﻛﻦ ﺍﻟﻌﺎﻣﺔ ﻭﺍﻷﺣﻴﺎﺀ ﺍﻟﺴﻜﻨﻴﺔ‪.‬‬

‫‪www.sedd.ae‬‬ ‫‪80080000‬‬
‫ﺍﻟﺸﺎﺭﻗﺔ‪-‬ﺻﻨﺎﻋﻴﺔ ﺭﻗﻢ‪/13‬ﺍﻟﺸﺎﺭﻗﺔ‪-‬ﺷﺎﺭﻉ ﺍﻟﺸﻴﺦ ﻣﺤﻤﺪ ﺑﻦ ﺯﺍﻳﺪ ﻣﻜﺘﺐ‪-‬ﻣﺤﻞ ﺭﻗﻢ ‪B/3 48-72-73-74-75-76-77-‬ﺷﺒﺮﺓ‪-‬‬ ‫ﺍﻟﻌﻨﻮﺍﻥ‬
‫ﻣﺤﻞ‪-‬ﻣﺤﻞ ﺭﻗﻢ ‪B/2 33-35-‬ﻣﺤﻞ ﺭﻗﻢ ‪B/4 87-95-96-97-98-99-101-102-103-104-105-106-107-108-109-‬‬
‫‪110-110-110-110-111-112-113-114-‬ﻣﻜﺘﺐ‪-‬ﺃﺭﺽ ﻣﺴﻮﺭﺓ ﻣﻠﻚ ﺍﺱ‪.‬ﻛﻲ‪.‬ﺍﻡ ﻟﻠﺘﻜﻴﻴﻒ ﺫ‪.‬ﻡ‪.‬ﻡ‬

‫‪0565379334‬‬ ‫ﺍﻟﻬﺎﺗﻒ ﺍﻟﻤﺘﺤﺮﻙ‪:‬‬

‫ﺍﻟﺸﺎﺭﻗﺔ ‪6004‬‬ ‫ﺻﻨﺪﻭﻕ ﺍﻟﺒﺮﻳﺪ‪:‬‬

‫‪[email protected]‬‬ ‫ﺍﻟﺒﺮﻳﺪ ﺍﻻﻟﻜﺘﺮﻭﻧﻲ‪:‬‬

‫‪Notes‬‬ ‫ﺍﻟﻤﻼﺣﻈﺎﺕ‬

‫‪-‬ﻳﺼﺮﺡ ﻟﻪ ﺑﻤﺰﺍﻭﻟﺔ ﺍﻟﻨﺸﺎﻁ ‪ 24‬ﺳﺎﻋﺔ‬

‫‪User Name‬‬ ‫‪53544‬‬ ‫ﺭﻗﻢ ﺍﻟﻤﺴﺘﺨﺪﻡ‬ ‫‪Printing Date‬‬ ‫‪15-04-2024‬‬ ‫ﺗﺎﺭﻳﺦ ﺍﻟﻄﺒﺎﻋﺔ‬
‫‪- This document is official. It doesn't need to be stamped or signed.‬‬ ‫‪ -‬ﻫﺬﻩ ﺍﻟﻮﺛﻴﻘﺔ ﺭﺳﻤﻴﺔ ﻭﻻ ﺗﺤﺘﺎﺝ ﻟﺨﺘﻢ ﺃﻭ ﺗﻮﻗﻴﻊ‪.‬‬
‫‪To view license details please visit SEDD web site: www.sedd.ae‬‬ ‫ﻟﻠﺘﺄﻛﺪ ﻣﻦ ﺻﺤﺔ ﺍﻟﺒﻴﺎﻧﺎﺕ ﻳﺮﺟﻰ ﺯﻳﺎﺭﺓ ﻣﻮﻗﻊ ﺍﻟﺪﺍﺋﺮﺓ‪www.sedd.ae :‬‬
‫‪- It is prohibited to distribute advertisements in public places and residential areas.‬‬ ‫‪ -‬ﻳﻤﻨﻊ ﺗﻮﺯﻳﻊ ﺍﻹﻋﻼﻧﺎﺕ ﻓﻲ ﺍﻷﻣﺎﻛﻦ ﺍﻟﻌﺎﻣﺔ ﻭﺍﻷﺣﻴﺎﺀ ﺍﻟﺴﻜﻨﻴﺔ‪.‬‬

‫‪www.sedd.ae‬‬ ‫‪80080000‬‬
‫ﺷﻬﺎﺩﺓ ﺳﺠﻞ ﺻﻨﺎﻋﻴﺔ‬
‫‪Industrial Register Certificate‬‬
‫‪License Details‬‬ ‫ﺗﻔﺎﺻﻴﻞ ﺍﻟﺮﺧﺼﺔ‬

‫‪Issue Date‬‬ ‫‪16-01-1975‬‬ ‫‪ License No.‬ﺗﺎﺭﻳﺦ ﺍﻹﺻﺪﺍﺭ‬ ‫‪341‬‬ ‫ﺭﻗﻢ ﺍﻟﺮﺧﺼﺔ‬

‫‪Expiry Date‬‬ ‫‪17-04-2025‬‬ ‫‪ Registration No.‬ﺗﺎﺭﻳﺦ ﺍﻹﻧﺘﻬﺎﺀ‬ ‫‪37171‬‬ ‫ﺭﻗﻢ ﺍﻟﺴﺠﻞ‬

‫‪Capital‬‬ ‫‪1000000‬‬ ‫ﺭﺃﺱ ﺍﻟﻤﺎﻝ‬

‫ﺍﺱ‪.‬ﻛﻲ‪.‬ﺍﻡ ﻟﻠﺘﻜﻴﻴﻒ ﺫ ﻡ ﻡ‬ ‫ﺍﻻﺳﻢ ﺍﻟﺘﺠﺎﺭﻱ‬

‫‪Trade Name‬‬ ‫‪S.K.M AIR CONDITIONING LLC‬‬

‫‪Legal status‬‬ ‫‪Limited Liability Company‬‬ ‫ﺷﺮﻛﺔ ﺫﺍﺕ ﻣﺴﺆﻭﻟﻴﺔ ﻣﺤﺪﻭﺩﺓ‬ ‫ﺍﻟﺸﻜﻞ ﺍﻟﻘﺎﻧﻮﻧﻲ‬

‫ﻋﺒﺪﺍﻟﻜﺮﻳﻢ ﺍﺑﺮﺍﻫﻴﻢ ﻋﺒﺪﺍﻟﻤﻠﻚ‪ ,‬ﻣﺒﺎﺭﻙ ﺳﻌﻮﺩ ﻋﺒﺪﺍﻟﻌﺰﻳﺰ ﺧﺎﻟﺪ ﺍﻟﺒﺸﺎﺭﻩ‪ ,‬ﻭﻟﻴﺪ ﺧﺎﻟﺪ ﻋﺒﺪﺍﻟﻠﻪ ﻣﺤﻤﺪ ﺍﻟﻤﺴﻔﺮ‬ ‫ﺍﻟﻤﺪﻳﺮ‬

‫ﺻﻨﺎﻋﺔ ﻭﺣﺪﺍﺕ ﺍﻟﺘﻜﻴﻴﻒ‪,‬ﺇﺻﻼﺡ ﻭﺻﻴﺎﻧﺔ ﻣﻜﻴﻔﺎﺕ ﺍﻟﻬﻮﺍﺀ ﻣﻌﺪﺍﺕ ﺍﻟﺘﺒﺮﻳﺪ ﻭﺗﻨﻘﻴﺔ ﺍﻟﻬﻮﺍﺀ‪,‬ﺻﻨﺎﻋﺔ ﻣﻌﺪﺍﺕ ﺗﻜﻴﻴﻒ ﺍﻟﻬﻮﺍﺀ ﺍﻟﻤﺮﻛﺰﻱ‬ ‫ﺃﻧﺸﻄﺔ ﺍﻟﺮﺧﺼﺔ‬
‫ﺍﻟﺸﺎﺭﻗﺔ‪-‬ﺻﻨﺎﻋﻴﺔ ﺭﻗﻢ‪/13‬ﺍﻟﺸﺎﺭﻗﺔ‪-‬ﺷﺎﺭﻉ ﺍﻟﺸﻴﺦ ﻣﺤﻤﺪ ﺑﻦ ﺯﺍﻳﺪ ﻣﻜﺘﺐ‪-‬ﻣﺤﻞ ﺭﻗﻢ ‪B/3 48-72-73-74-75-76-77-‬ﺷﺒﺮﺓ‪-‬ﻣﺤﻞ‪-‬ﻣﺤﻞ ﺭﻗﻢ ‪B/2 33-35-‬ﻣﺤﻞ ﺭﻗﻢ ‪B/4 87-95-96-97-98-99-‬‬
‫‪101-102-103-104-105-106-107-108-109-110-110-110-110-111-112-113-114-‬ﻣﻜﺘﺐ‪-‬ﺃﺭﺽ ﻣﺴﻮﺭﺓ ﻣﻠﻚ ﺍﺱ‪.‬ﻛﻲ‪.‬ﺍﻡ ﻟﻠﺘﻜﻴﻴﻒ ﺫ‪.‬ﻡ‪.‬ﻡ‬ ‫ﺍﻟﻌﻨﻮﺍﻥ‬

‫‪User Name‬‬ ‫‪53544‬‬ ‫ﺭﻗﻢ ﺍﻟﻤﺴﺘﺨﺪﻡ‬ ‫‪Printing Date‬‬ ‫‪15-04-2024‬‬ ‫ﺗﺎﺭﻳﺦ ﺍﻟﻄﺒﺎﻋﺔ‬
‫‪- This document is official. It doesn't need to be stamped or signed.‬‬ ‫‪ -‬ﻫﺬﻩ ﺍﻟﻮﺛﻴﻘﺔ ﺭﺳﻤﻴﺔ ﻭﻻ ﺗﺤﺘﺎﺝ ﻟﺨﺘﻢ ﺃﻭ ﺗﻮﻗﻴﻊ‪.‬‬
‫‪To view license details please visit SEDD web site: www.sedd.ae‬‬ ‫ﻟﻠﺘﺄﻛﺪ ﻣﻦ ﺻﺤﺔ ﺍﻟﺒﻴﺎﻧﺎﺕ ﻳﺮﺟﻰ ﺯﻳﺎﺭﺓ ﻣﻮﻗﻊ ﺍﻟﺪﺍﺋﺮﺓ‪www.sedd.ae :‬‬
‫‪- It is prohibited to distribute advertisements in public places and residential areas.‬‬ ‫‪ -‬ﻳﻤﻨﻊ ﺗﻮﺯﻳﻊ ﺍﻹﻋﻼﻧﺎﺕ ﻓﻲ ﺍﻷﻣﺎﻛﻦ ﺍﻟﻌﺎﻣﺔ ﻭﺍﻷﺣﻴﺎﺀ ﺍﻟﺴﻜﻨﻴﺔ‪.‬‬

‫‪www.sedd.ae‬‬ ‫‪80080000‬‬
Economic License ‫ﺭﺧﺼــﺔ ﺍﻗﺘﺼﺎﺩﻳﺔ‬
Commercial License ‫ﺭﺧـﺼــــــﺔ ﺗﺠﺎﺭﻳﺔ‬
Emerging Economic Establishment ‫ﻣﻨﺸــــﺄﺓ ﺍﻗﺘﺼـــﺎﺩﻳــــﺔ ﻧﺎﺷﺌـــــــﺔ‬

License No : CN-2816069 : ‫ﺭﻗﻢ ﺍﻟﺮﺧﺼﺔ‬


ADCCI No : 2608770 : ‫ﻋﻀﻮﻳﺔ ﺍﻟﻐﺮﻓﺔ‬

Establishment Card : 1055077 : ‫ﻭﺯﺍﺭﺓ ﺍﻟﻤﻮﺍﺭﺩ ﺍﻟﺒﺸﺮﻳﺔ ﻭﺍﻟﺘﻮﻃﻴﻦ‬


MOHRE ‫ﺑﻄﺎﻗﺔ ﺍﻟﻤﻨﺸﺄﺓ‬
Establishment Card : 667866 : ‫ﺍﻟﻬﻴﺌﺔ ﺍﻻﺗﺤﺎﺩﻳﺔ ﻟﻠﻬﻮﻳﺔ‬
ICA ‫ ﺑﻄﺎﻗﺔ ﺍﻟﻤﻨﺸﺄﺓ‬-‫ﻭﺍﻟﺠﻨﺴﻴﺔ‬
Legal Form : Limited Liability Company ‫ ﺷﺮﻛﺔ ﺫﺍﺕ ﻣﺴﺆﻭﻟﻴﺔ ﻣﺤﺪﻭﺩﺓ‬: ‫ﺍﻟﺸﻜﻞ ﺍﻟﻘﺎﻧﻮﻧﻲ‬

‫ﻡ‬.‫ﻡ‬.‫ ﺍﺱ ﻛﻲ ﺍﻡ ﺍﻧﺘﺮﻧﺎﺷﻴﻮﻧﺎﻝ ﻟﻠﺘﺒﺮﻳﺪ ﻭﺍﻟﺘﻜﻴﻴﻒ ﺫ‬: ‫ﺍﻹﺳﻢ ﺍﻟﺘﺠﺎﺭﻱ‬


Trade Name : SKM INTERNATIONAL REFRIGERATION & AIR CONDITIONING L.L.C.
Establishment Date : 03/09/2019 : ‫ﺗﺎﺭﻳﺦ ﺗﺄﺳﻴﺲ ﺍﻟﻤﻨﺸﺄﺓ‬
Issue Date : 18/09/2023 : ‫ﺗﺎﺭﻳﺦ ﺍﻹﺻﺪﺍﺭ‬
Expiry Date : : ‫ﺗﺎﺭﻳﺦ ﺍﻹﻧﺘﻬﺎﺀ‬
17/09/2024

‫ﺍﻟﺼﻠﺔ‬ ‫ﺍﻟﺠﻨﺴﻴﺔ‬ ‫ ﺍﻟﺸﺮﻛﺎﺀ‬/ ‫ﺍﻟﻤﻼﻙ‬ ‫ﺍﻟﺮﻣﺰ‬


Role Nationality Owners / Partners No.

‫ﺷﺮﻳﻚ‬ ‫ﺍﻹﻣﺎﺭﺍﺕ ﺍﻟﻌﺮﺑﻴﺔ ﺍﻟﻤﺘﺤﺪﺓ‬ ‫ﻣﺤﻤﺪ ﺛﻌﻠﻮﺏ ﺳﺎﻟﻢ ﺣﻤﺪ ﺍﻟﺪﺭﻋﻰ‬ 41745861
Partner United Arab Emirates MOHAMED THAALOOB SALEM HAMAD ALDEREI
‫ﺷﺮﻳﻚ‬ ‫ﺍﻹﻣﺎﺭﺍﺕ ﺍﻟﻌﺮﺑﻴﺔ ﺍﻟﻤﺘﺤﺪﺓ‬ ‫ﺷﺮﻛﺔ ﺍﺱ ﻛﻲ ﺍﻡ ﻟﻠﺘﻜﻴﻴﻒ ﺫ ﻡ ﻡ‬ 41745862
Partner United Arab Emirates SKM AIR CONDITIONING LLC
‫ﻣﺪﻳﺮ‬ ‫ﺍﻟﻜﻮﻳﺖ‬ ‫ﻋﺒﺪﺍﻟﻜﺮﻳﻢ ﺍﺑﺮﺍﻫﻴﻢ ﻋﺒﺪﺍﻟﻤﻠﻚ ﺍﻟﺼﺎﻟﺢ‬ 41865307
Manager Kuwait ABDULKARIM E A ALSALEH
‫ﻣﺪﻳﺮ‬ ‫ﺍﻟﻜﻮﻳﺖ‬ ‫ﻣﺒﺎﺭﻙ ﺳﻌﻮﺩ ﻋﺒﺪﺍﻟﻌﺰﻳﺰ ﺧﺎﻟﺪ ﺍﻟﺒﺸﺎﺭﻩ‬ 41472441
Manager Kuwait MUBARAK S A KH ALBESHARAH
Economic Activities : : ‫ﺍﻷﻧﺸﻄﺔ ﺍﻻﻗﺘﺼﺎﺩﻳﺔ‬
- * Air Conditioning, Ventilation Air Cooling Systems Maintenance, Installation and ‫ * ﻣﻘﺎﻭﻻﺕ ﺗﺮﻛﻴﺐ ﺃﻧﻈﻤﺔ ﺍﻟﺘﻜﻴﻴﻒ ﻭﺍﻟﺘﻬﻮﻳﺔ ﻭﺗﺒﺮﻳﺪ ﺍﻟﻬﻮﺍﺀ ﻭﺻﻴﺎﻧﺘﻬﺎ‬-
Contracting
- Central Air-Conditioners Maintenance ‫ ﺻﻴﺎﻧﺔ ﺃﺟﻬﺰﺓ ﺍﻟﺘﻜﻴﻴﻒ ﺍﻟﻤﺮﻛﺰﻱ‬-
- Buildings Energy Efficiency Services ‫ ﺧﺪﻣﺎﺕ ﻛﻔﺎﺀﺓ ﺍﻟﻄﺎﻗﺔ ﻓﻲ ﺍﻟﻤﺒﺎﻧﻲ‬-
- Wholesale of Air-Conditioner and Coolant Spare Parts Trading ‫ ﺑﺎﻟﺠﻤﻠﺔ‬- ‫ ﺗﺠﺎﺭﺓ ﻗﻄﻊ ﻏﻴﺎﺭ ﺍﺟﻬﺰﺓ ﺍﻟﺘﻜﻴﻴﻒ ﻭﺍﻟﺘﺒﺮﻳﺪ‬-
- Onshore And Offshore Oil And Gas Fields And Facilities Services ‫ ﺧﺪﻣﺎﺕ ﺣﻘﻮﻝ ﻭﻣﻨﺸﺄﺕ ﺍﻟﻨﻔﻂ ﻭﺍﻟﻐﺎﺯ ﺍﻟﺒﺮﻳﺔ ﻭﺍﻟﺒﺤﺮﻳﺔ‬-
- * Electrical Contracting ‫ * ﺍﻟﻤﻘﺎﻭﻻﺕ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬-
- Repair and Maintenance of Air-Conditioners, Cooling Equipments and Central Air ‫ ﺇﺻﻼﺡ ﻭﺻﻴﺎﻧﺔ ﻣﻜﻴﻔﺎﺕ ﺍﻟﻬﻮﺍﺀ ﻭ ﻣﻌﺪﺍﺕ ﺍﻟﺘﺒﺮﻳﺪ ﻭﺗﻨﻘﻴﺔ ﺍﻟﻬﻮﺍﺀ‬-
Refining
- Retail Sale Air-Conditioner and Coolant Spare Parts ‫ ﺑﻴﻊ ﻗﻄﻊ ﻏﻴﺎﺭ ﺍﺟﻬﺰﺓ ﺍﻟﺘﻜﻴﻴﻒ ﻭﺍﻟﺘﺒﺮﻳﺪ – ﺑﺎﻟﺘﺠﺰﺋﻪ‬-

Official Email : [email protected] : ‫ﺍﻟﺒﺮﻳﺪ ﺍﻹﻟﻜﺘﺮﻭﻧﻲ ﺍﻟﺮﺳﻤﻲ‬


Official Mobile : +971564914549 : ‫ﺭﻗﻢ ﺍﻟﺘﻮﺍﺻﻞ ﺍﻟﺮﺳﻤﻲ‬

TAHAQAQ ‫ﺗﺤﻘﻖ‬

www.added.gov.ae
www.tamm.abudhabi ‫ ﻟﻠﺘﺤﻘﻖ ﻣﻦ ﺻﺤﺔ ﺍﻟﺒﻴﺎﻧﺎﺕ ﺍﻟﻮﺍﺭﺩﺓ ﻓﻲ ﺍﻟﺮﺧﺼﺔ ﺑﺮﺟﺎﺀ ﺯﻳﺎﺭﺓ ﺍﻟﻤﻮﻗﻊ‬.‫ ﺃﺑﻮﻇﺒﻲ‬- ‫ﻭﺛﻴﻘﺔ ﻣﻌﺘﻤﺪﺓ ﻭﺻﺎﺩﺭﺓ ﺑﺪﻭﻥ ﺗﻮﻗﻴﻊ ﺃﻭ ﺧﺘﻢ ﻣﻦ ﺩﺍﺋﺮﺓ ﺍﻟﺘﻨﻤﻴﺔ ﺍﻹﻗﺘﺼﺎﺩﻳﺔ‬
Approved document issued without signature or stamp by the Department of Economic Development - Abu Dhabi. To verify the license
kindly
- Importing ‫ ﺍﺳﺘﻴﺮﺍﺩ‬-
- * Mechanical Contracting ‫ * ﺍﻟﻤﻘﺎﻭﻻﺕ ﺍﻟﻤﻴﻜﺎﻧﻴﻜﻴﺔ‬-

The Contractor is not permitted to practice the activities marked with sign ‫ﻻ ﻳﺤﻖ ﻟﻠﻤﻘﺎﻭﻝ ﻣﻤﺎﺭﺳﺔ ﺍﻷﻧﺸﻄﺔ ﺍﻟﻤﺸﺎﺭ ﺇﻟﻴﻬﺎ ﺑﻌﻼﻣﺔ )*( ﺇﻻ ﺑﻌﺪ ﺍﻟﺤﺼﻮﻝ ﻋﻠﻰ ﺷﻬﺎﺩﺓ‬
(*) unless these activities are classified and a Classification certificate is .‫ﺍﻟﺘﺼﻨﻴﻒ ﺍﻟﻤﻌﺘﻤﺪﺓ ﻣﻦ ﺩﺍﺋﺮﺓ ﺍﻟﺘﺨﻄﻴﻂ ﺍﻟﻌﻤﺮﺍﻧﻲ ﻭﺍﻟﺒﻠﺪﻳﺎﺕ‬
obtained for the department of Department of Urban Planning and
Municipalities
Address : ‫ ﺍﻟﺸﻴﺨﺔ ﺷﻴﺨﻪ ﺑﻨﺖ ﺧﻠﻴﻔﻪ ﺑﻦ ﺯﺍﻳﺪ ﻭ ﺍﺧﺮﻳﻦ‬,~ : 0 ,16 ‫ ﺷﺮﻕ‬,‫ﺟﺰﻳﺮﺓ ﺍﺑﻮﻇﺒﻲ‬ : ‫ﺍﻟﻌﻨﻮﺍﻥ‬

Onwani Address : : ‫ﺍﻟﻌﻨﻮﺍﻥ ﺍﻟﻤﻮﺣﺪ‬

Official Email : [email protected] : ‫ﺍﻟﺒﺮﻳﺪ ﺍﻹﻟﻜﺘﺮﻭﻧﻲ ﺍﻟﺮﺳﻤﻲ‬


Official Mobile : +971564914549 : ‫ﺭﻗﻢ ﺍﻟﺘﻮﺍﺻﻞ ﺍﻟﺮﺳﻤﻲ‬

TAHAQAQ ‫ﺗﺤﻘﻖ‬

www.added.gov.ae
www.tamm.abudhabi ‫ ﻟﻠﺘﺤﻘﻖ ﻣﻦ ﺻﺤﺔ ﺍﻟﺒﻴﺎﻧﺎﺕ ﺍﻟﻮﺍﺭﺩﺓ ﻓﻲ ﺍﻟﺮﺧﺼﺔ ﺑﺮﺟﺎﺀ ﺯﻳﺎﺭﺓ ﺍﻟﻤﻮﻗﻊ‬.‫ ﺃﺑﻮﻇﺒﻲ‬- ‫ﻭﺛﻴﻘﺔ ﻣﻌﺘﻤﺪﺓ ﻭﺻﺎﺩﺭﺓ ﺑﺪﻭﻥ ﺗﻮﻗﻴﻊ ﺃﻭ ﺧﺘﻢ ﻣﻦ ﺩﺍﺋﺮﺓ ﺍﻟﺘﻨﻤﻴﺔ ﺍﻹﻗﺘﺼﺎﺩﻳﺔ‬
Approved document issued without signature or stamp by the Department of Economic Development - Abu Dhabi. To verify the license
kindly
CERTIFICATES
Certificate of Registration
ENVIRONMENTAL MANAGEMENT SYSTEM - ISO 14001:2015

This is to certify that: SKM Air Conditioning LLC


Head Office
Industrial Area 13,
6004 Sharjah
United Arab Emirates

Holds Certificate No: EMS 736665


and operates an Environmental Management System which complies with the requirements of ISO 14001:2015 for
the following scope:

Design, manufacture, sales, installation, maintenance, rectification, technical support and


customer services of heating, ventilation, refrigeration and air-conditioning equipment.

For and on behalf of BSI:


Theuns Kotze, Managing Director Assurance - IMETA

Original Registration Date: 2017-10-11 Effective Date: 2023-10-11


Latest Revision Date: 2023-11-07 Expiry Date: 2026-10-10

Page: 1 of 1

This certificate was issued electronically and remains the property of BSI and is bound by the conditions of contract.
An electronic certificate can be authenticated online.
Printed copies can be validated at www.bsigroup.com/ClientDirectory

Information and Contact: BSI, Kitemark Court, Davy Avenue, Knowlhill, Milton Keynes MK5 8PP. Tel: + 44 345 080 9000
BSI Assurance UK Limited, registered in England under number 7805321 at 389 Chiswick High Road, London W4 4AL, UK.
A Member of the BSI Group of Companies.
Certificate of Registration
OCCUPATIONAL HEALTH & SAFETY MANAGEMENT SYSTEM - ISO 45001:2018

This is to certify that: SKM Air Conditioning LLC


Head Office
Industrial Area 13,
6004 Sharjah
United Arab Emirates

Holds Certificate No: OHS 736679


and operates an Occupational Health and Safety Management System which complies with the requirements of
ISO 45001:2018 for the following scope:

Design, manufacture, sales, installation, maintenance, rectification, technical support and


customer services of heating, ventilation, refrigeration and air-conditioning equipment.

For and on behalf of BSI:


Theuns Kotze, Managing Director Assurance - IMETA

Original Registration Date: 2017-10-11 Effective Date: 2023-10-11


Latest Revision Date: 2023-11-07 Expiry Date: 2026-10-10

Page: 1 of 1

This certificate was issued electronically and remains the property of BSI and is bound by the conditions of contract.
An electronic certificate can be authenticated online.
Printed copies can be validated at www.bsigroup.com/ClientDirectory

Information and Contact: BSI, Kitemark Court, Davy Avenue, Knowlhill, Milton Keynes MK5 8PP. Tel: + 44 345 080 9000
BSI Assurance UK Limited, registered in England under number 7805321 at 389 Chiswick High Road, London W4 4AL, UK.
A Member of the BSI Group of Companies.
Certificate of Registration
QUALITY MANAGEMENT SYSTEM - ISO 9001:2015

This is to certify that: SKM Air Conditioning LLC


Head Office
Industrial Area 13,
6004 Sharjah
United Arab Emirates

Holds Certificate No: FM 736664


and operates a Quality Management System which complies with the requirements of ISO 9001:2015 for the
following scope:

Design, manufacture, sales, installation, maintenance, rectification, technical support and


customer services of heating, ventilation, refrigeration and air-conditioning equipment

For and on behalf of BSI:


Theuns Kotze, Managing Director Assurance - IMETA

Original Registration Date: 2017-10-11 Effective Date: 2023-10-11


Latest Revision Date: 2023-11-07 Expiry Date: 2026-10-10

Page: 1 of 1

This certificate was issued electronically and remains the property of BSI and is bound by the conditions of contract.
An electronic certificate can be authenticated online.
Printed copies can be validated at www.bsigroup.com/ClientDirectory

Information and Contact: BSI, Kitemark Court, Davy Avenue, Knowlhill, Milton Keynes MK5 8PP. Tel: + 44 345 080 9000
BSI Assurance UK Limited, registered in England under number 7805321 at 389 Chiswick High Road, London W4 4AL, UK.
A Member of the BSI Group of Companies.
‫ﺑﯿــــﺎن اﻟﺘــﺴﺠﯿﻞ‬
SCHEDULE OF CERTIFICATION
Air Cooled
Package Unit:
380-415 V 3N ~,
50 Hz, 9.87 KW,
SKM Air UAE.S United
82800 Btu/h, 18.2 PKG-0822-
313 Conditioning APMR51100G1 N/A 5010- Arab
A, PF0.78, R- 151
Equipment 5:2019 Emirates
410A / 9.22Kg,
CSPF: 3.1 , EER:
8.39, Climate
Class T3
Air Cooled
Package Unit:
380-415 V 3N ~,
50 Hz, 11.38 KW,
SKM Air UAE.S United
95700 Btu/h, 21.1 PKG-0822-
314 Conditioning APMR51120G1 N/A 5010- Arab
A, PF0.78, R- 153
Equipment 5:2019 Emirates
410A / 13.44Kg,
CSPF: 3.2 , EER:
8.41, Climate
Class T3
Air Cooled
Package Unit:
380-415 V 3N ~,
50 Hz, 12.87 KW,
SKM Air UAE.S United
108100 Btu/h, PKG-0822-
315 Conditioning APMR52130G1 N/A 5010- Arab
23.7 A, PF0.79, 155
Equipment 5:2019 Emirates
R-410A /
14.32Kg, CSPF:
3.07 , EER: 8.4,
Climate Class T3

‫جهة معينة من قبل وزارة الصناعة والتكنولوجيا المتقدمة‬


Notified body by Ministry of Industry and Advanced Technology

This is an electronic certificate and does not


‫ أي‬،‫هذه الشهادة صدرت إلكترونيًا والتحتاج لختم أو توقيع‬
require stamp and signature. Certificate will be
invalid in case of any modification
.‫كشط أو تغيير في هذه الشهادة يلغيها‬

Page 82 of 104
‫ﺑﯿــــﺎن اﻟﺘــﺴﺠﯿﻞ‬
SCHEDULE OF CERTIFICATION
Air Cooled
Package Unit:
380-415 V 3N ~,
50 Hz, 14.68 KW,
SKM Air UAE.S United
123300 Btu/h, PKG-0822-
316 Conditioning APMR52150G1 N/A 5010- Arab
27.9 A, PF0.76, 157
Equipment 5:2019 Emirates
R-410A /
14.32Kg, CSPF:
3.04 , EER: 8.4,
Climate Class T3
Air Cooled
Package Unit:
380-415 V 3N ~,
50 Hz, 16.32 KW,
SKM Air UAE.S United
135900 Btu/h, PKG-0822-
317 Conditioning APMR52170G1 N/A 5010- Arab
29.7 A, PF0.79, 159
Equipment 5:2019 Emirates
R-410A /
18.38Kg, CSPF:
3.03 , EER: 8.33,
Climate Class T3
Air Cooled
Package Unit:
380-415 V 3N ~,
50 Hz, 17.79 KW,
SKM Air UAE.S United
145800 Btu/h, PKG-0822-
318 Conditioning APMR52180G1 N/A 5010- Arab
31.7 A, PF0.81, 161
Equipment 5:2019 Emirates
R-410A /
18.38Kg, CSPF:
2.99 , EER: 8.2,
Climate Class T3

‫جهة معينة من قبل وزارة الصناعة والتكنولوجيا المتقدمة‬


Notified body by Ministry of Industry and Advanced Technology

This is an electronic certificate and does not


‫ أي‬،‫هذه الشهادة صدرت إلكترونيًا والتحتاج لختم أو توقيع‬
require stamp and signature. Certificate will be
invalid in case of any modification
.‫كشط أو تغيير في هذه الشهادة يلغيها‬

Page 83 of 104
‫ﺑﯿــــﺎن اﻟﺘــﺴﺠﯿﻞ‬
SCHEDULE OF CERTIFICATION
Air Cooled
Package Unit:
380-415 V 3N ~,
50 Hz, 19.8 KW,
SKM Air UAE.S United
162700 Btu/h, PKG-0822-
319 Conditioning APMR52210G1 N/A 5010- Arab
36.9 A, PF0.77, 163
Equipment 5:2019 Emirates
R-410A /
26.12Kg, CSPF:
3.04 , EER: 8.2,
Climate Class T3
Air Cooled
Package Unit:
380-415 V 3N ~,
50 Hz, 23.08 KW,
SKM Air UAE.S United
188900 Btu/h, PKG-0822-
320 Conditioning APMR52240G1 N/A 5010- Arab
42.6 A, PF0.78, 164
Equipment 5:2019 Emirates
R-410A /
27.24Kg, CSPF:
3.09 , EER: 8.18,
Climate Class T3
Air Cooled
Package Unit:
380-415 V 3N ~,
50 Hz, 25.77 KW,
SKM Air UAE.S United
212900 Btu/h, PKG-0822-
321 Conditioning APMR52270G1 N/A 5010- Arab
47.4 A, PF0.78, 165
Equipment 5:2019 Emirates
R-410A /
28.34Kg, CSPF:
3.16 , EER: 8.26,
Climate Class T3

‫جهة معينة من قبل وزارة الصناعة والتكنولوجيا المتقدمة‬


Notified body by Ministry of Industry and Advanced Technology

This is an electronic certificate and does not


‫ أي‬،‫هذه الشهادة صدرت إلكترونيًا والتحتاج لختم أو توقيع‬
require stamp and signature. Certificate will be
invalid in case of any modification
.‫كشط أو تغيير في هذه الشهادة يلغيها‬

Page 84 of 104
‫ﺑﯿــــﺎن اﻟﺘــﺴﺠﯿﻞ‬
SCHEDULE OF CERTIFICATION
Split Type Air
Conditioner -
Ducted: 380-415
V 3N ~, 50 Hz,
SKM Air 27.01 KW, UAE.S United
AUMR260G1+CADX SUS-0822-
373 Conditioning 218840 Btu/h, N/A 5010- Arab
260AG1 183
Equipment 50.3 A, PF0.77, 5:2019 Emirates
R-410A /
26.62Kg, CSPF:
2.98 , EER: 8.1,
Climate Class T3
Ducted Units:
220-240 V, 50Hz,
3.5 KW, 30500
SKM Air 02-SUS- UAE.S United
RX36PS1HC05N + Btu/h, 16 A, PF:
374 Conditioning N/A 0319-QHSE- 5010- Arab
FCUDDP363PC05N 0.95, R410A /
Equipment 320 R1 5:2019 Emirates
2.55Kg, CSPF:
3.04 , EER: 8.71,
Climate Class T3
Ducted Units:
220-240 V, 50Hz,
2.1 KW, 17500
SKM Air 02-SUS- UAE.S United
RXVPG-018C0V + Btu/h, 10.24 A,
375 Conditioning N/A 0121-ENG- 5010- Arab
DDPPG-018CVV PF: 0.98, R410A /
Equipment 45 R4 5:2019 Emirates
3.6Kg, CSPF: 2.9
, EER: 8.33,
Climate Class T3
Ducted Units:
220-240 V, 50Hz,
2.26 KW, 19400
SKM Air SUS-1118- UAE.S United
RXVPG-024C0V + Btu/h, 9.92 A, PF:
376 Conditioning N/A RND-1012 5010- Arab
DDPPG-024CVV 0.96, R410A /
Equipment R4 5:2019 Emirates
3.6Kg, CSPF:
3.02 , EER: 8.58,
Climate Class T3

‫جهة معينة من قبل وزارة الصناعة والتكنولوجيا المتقدمة‬


Notified body by Ministry of Industry and Advanced Technology

This is an electronic certificate and does not


‫ أي‬،‫هذه الشهادة صدرت إلكترونيًا والتحتاج لختم أو توقيع‬
require stamp and signature. Certificate will be
invalid in case of any modification
.‫كشط أو تغيير في هذه الشهادة يلغيها‬

Page 102 of 104


‫وﺛﯿﻘﺔ اﻟﻤﻄﺎﺑﻘﺔ‬
Conformity Document

Certificate No: QAD-2023.1024.01-AC :‫رﻗﻢ اﻟﺸﮫﺎدة‬


Expiry Date: 26 March 2024 :‫ﺗﺎرﻳﺦ اﻹﻧﺘﮫﺎء‬

Issuing Date: 27 March 2023 :‫ﺗﺎرﻳﺦ اﻹﺻﺪار‬

Conformity Ozone Friendly Air Cooled Unitary Air


:‫ﺑﺮﻧﺎﻣﺞ اﻟﻤﻄﺎﺑﻘﺔ‬
Scheme: Conditioners

Product: Packaged Air Conditioner :‫اﻟﻤﻨﺘﺞ‬

Name and Address SKM Air Conditioning LLC ‫اﺳﻢ و ﻋﻨﻮان ﺻﺎﺣﺐ‬
of the Licensee: Industrial 13 6004 Sharjah UAE :‫اﻟﺤﻖ ﺑﺈﺳﺘﺨﺪام اﻟﻌﻼﻣﺔ‬

Name and Address


SKM Air Conditioning LLC ‫اﺳﻢ وﻋﻨﻮان اﻟﻤﺼﻨﻊ‬
of the Manufacturer
Industrial 13 6004 Sharjah UAE :‫وﻣﻜﺎن اﻟﺘﺼﻨﯿﻊ‬
and the Factory:

Trademark / Brand ‫ اﻻﺳﻢ‬/ ‫اﻟﻌﻼﻣﺔ اﻟﺘﺠﺎرﻳﺔ‬


SKM AIR CONDITIONING EQUIPMENT
Name: :‫اﻟﺘﺠﺎري‬

QAD-2023.1024.01-AC

This is an electronic certificate and does not require stamp ‫ھذه اﻟﺷﮭﺎدة ﺻدرت إﻟﻛﺗروﻧﯾﺎ ً وﻻ ﺗﺣﺗﺎج إﻟﻰ ﺧﺗم‬

Visit our website to verify this certificate: :‫ﻟﻠﺗﺄﻛد ﻣن ﺻﺣﺔ ھذه اﻟﺷﮭﺎدة ﯾرﺟﻰ زﯾﺎرة ﻣوﻗﻊ ﺟودة اﻹﻟﻛﺗروﻧﻲ‬

https://jawdah.qcc.abudhabi.ae/en/pages/homepage.aspx https://jawdah.qcc.abudhabi.ae/en/Pages/homepage.aspx

Any changes or modification on this certificate will affect its validity ‫أي ﻛﺷط أو ﺗﻐﯾﯾر ﻓﻲ ھذه اﻟﺷﮭﺎدة ﯾﻠﻐﯾﮭﺎ‬

Page 1 of 3
‫وﺛﯿﻘﺔ اﻟﻤﻄﺎﺑﻘﺔ‬
Conformity Document

Certificate No: QAD-2023.1024.01-AC :‫رﻗﻢ اﻟﺸﮫﺎدة‬


Expiry Date: 26 March 2024 :‫ﺗﺎرﻳﺦ اﻹﻧﺘﮫﺎء‬

Model Characteristics Additional information


Rated cooling capacity at T3 conditions (kW): 13.66; COP at T1 UAE.S 5010-5:2019, UAE.S
APMR51055G1 conditions (W/W): 3.456; Power Factor at T3: 0.834; Refrigerant: ISO 13253:2011, UAE.S ISO
R410A 16358:2013+Amd.1:2019
Rated cooling capacity at T3 conditions (kW): 17.35; COP at T1 UAE.S 5010-5:2019, UAE.S
APMR51070G1 conditions (W/W): 3.401; Power Factor at T3: 0.78; Refrigerant: ISO 13253:2011, UAE.S ISO
R410A 16358:2013+Amd.1:2019
Rated cooling capacity at T3 conditions (kW): 19.46; COP at T1 UAE.S 5010-5:2019, UAE.S
APMR51080G1 conditions (W/W): 3.425; Power Factor at T3: 0.8; Refrigerant: ISO 13253:2011, UAE.S ISO
R410A 16358:2013+Amd.1:2019
Rated cooling capacity at T3 conditions (kW): 21.25; COP at T1 UAE.S 5010-5:2019, UAE.S
APMR51090G1 conditions (W/W): 3.518; Power Factor at T3: 0.82; Refrigerant: ISO 13253:2011, UAE.S ISO
R410A 16358:2013+Amd.1:2019
Rated cooling capacity at T3 conditions (kW): 24.27; COP at T1 UAE.S 5010-5:2019, UAE.S
APMR51100G1 conditions (W/W): 3.513; Power Factor at T3: 0.987; Refrigerant: ISO 13253:2011, UAE.S ISO
R410A 16358:2013+Amd.1:2019
Rated cooling capacity at T3 conditions (kW): 28.05; COP at T1 UAE.S 5010-5:2019, UAE.S
APMR51120G1 conditions (W/W): 3.564; Power Factor at T3: 0.81; Refrigerant: ISO 13253:2011, UAE.S ISO
R410A 16358:2013+Amd.1:2019
Rated cooling capacity at T3 conditions (kW): 31.68; COP at T1 UAE.S 5010-5:2019, UAE.S
APMR52130G1 conditions (W/W): 3.584; Power Factor at T3: 0.82; Refrigerant: ISO 13253:2011, UAE.S ISO
R410A 16358:2013+Amd.1:2019
Rated cooling capacity at T3 conditions (kW): 36.14; COP at T1 UAE.S 5010-5:2019, UAE.S
APMR52150G1 conditions (W/W): 3.419; Power Factor at T3: 0.79; Refrigerant: ISO 13253:2011, UAE.S ISO
R410A 16358:2013+Amd.1:2019
Rated cooling capacity at T3 conditions (kW): 39.83; COP at T1 UAE.S 5010-5:2019, UAE.S
APMR52170G1 conditions (W/W): 3.447; Power Factor at T3: 0.79; Refrigerant: ISO 13253:2011, UAE.S ISO
R410A 16358:2013+Amd.1:2019
Rated cooling capacity at T3 conditions (kW): 42.73; COP at T1 UAE.S 5010-5:2019, UAE.S
APMR52180G1 conditions (W/W): 3.317; Power Factor at T3: 0.83; Refrigerant: ISO 13253:2011, UAE.S ISO
R410A 16358:2013+Amd.1:2019

QAD-2023.1024.01-AC

This is an electronic certificate and does not require stamp ‫ھذه اﻟﺷﮭﺎدة ﺻدرت إﻟﻛﺗروﻧﯾﺎ ً وﻻ ﺗﺣﺗﺎج إﻟﻰ ﺧﺗم‬

Visit our website to verify this certificate: :‫ﻟﻠﺗﺄﻛد ﻣن ﺻﺣﺔ ھذه اﻟﺷﮭﺎدة ﯾرﺟﻰ زﯾﺎرة ﻣوﻗﻊ ﺟودة اﻹﻟﻛﺗروﻧﻲ‬

https://jawdah.qcc.abudhabi.ae/en/pages/homepage.aspx https://jawdah.qcc.abudhabi.ae/en/Pages/homepage.aspx

Any changes or modification on this certificate will affect its validity ‫أي ﻛﺷط أو ﺗﻐﯾﯾر ﻓﻲ ھذه اﻟﺷﮭﺎدة ﯾﻠﻐﯾﮭﺎ‬

Page 2 of 3
‫وﺛﯿﻘﺔ اﻟﻤﻄﺎﺑﻘﺔ‬
Conformity Document

Certificate No: QAD-2023.1024.01-AC :‫رﻗﻢ اﻟﺸﮫﺎدة‬


Expiry Date: 26 March 2024 :‫ﺗﺎرﻳﺦ اﻹﻧﺘﮫﺎء‬
Rated cooling capacity at T3 conditions (kW): 47.68; COP at T1 UAE.S 5010-5:2019, UAE.S
APMR52210G1 conditions (W/W): 3.330; Power Factor at T3: 0.77; Refrigerant: ISO 13253:2011, UAE.S ISO
R410A 16358:2013+Amd.1:2019
Rated cooling capacity at T3 conditions (kW): 55.36; COP at T1 UAE.S 5010-5:2019, UAE.S
APMR52240G1 conditions (W/W): 3.371; Power Factor at T3: 0.78; Refrigerant: ISO 13253:2011, UAE.S ISO
R410A 16358:2013+Amd.1:2019
Rated cooling capacity at T3 conditions (kW): 62.39; COP at T1 UAE.S 5010-5:2019, UAE.S
APMR52270G1 conditions (W/W): 3.448; Power Factor at T3: 0.83; Refrigerant: ISO 13253:2011, UAE.S ISO
R410A 16358:2013+Amd.1:2019
Rated cooling capacity at T3 conditions (kW): 70.51; COP at T1 UAE.S 5010-5:2019, UAE.S
APMR52300G1 conditions (W/W): 3.168; Power Factor at T3: 0.80; Refrigerant: ISO 13253:2011, UAE.S ISO
R410A 16358:2013+Amd.1:2019
Rated cooling capacity at T3 conditions (kW): 80.48; COP at T1 UAE.S 5010-5:2019, UAE.S
APMR52340G1 conditions (W/W): 3.214; Power Factor at T3: 0.76; Refrigerant: ISO 13253:2011, UAE.S ISO
R410A 16358:2013+Amd.1:2019
Rated cooling capacity at T3 conditions (kW): 93.58; COP at T1 UAE.S 5010-5:2019, UAE.S
APMR52380G1 conditions (W/W): 3.235; Power Factor at T3: 0.82; Refrigerant: ISO 13253:2011, UAE.S ISO
R410A 16358:2013+Amd.1:2019

Notes:Air Conditioners with power factor <0.9 can still be certified but can only be used in villa projects with power correction
mechanisms that comply with the DOE wiring regulations. The power unit of the air conditioner unit shall be demonstrated by
either test reports or engineering calculations

QAD-2023.1024.01-AC

This is an electronic certificate and does not require stamp ‫ھذه اﻟﺷﮭﺎدة ﺻدرت إﻟﻛﺗروﻧﯾﺎ ً وﻻ ﺗﺣﺗﺎج إﻟﻰ ﺧﺗم‬

Visit our website to verify this certificate: :‫ﻟﻠﺗﺄﻛد ﻣن ﺻﺣﺔ ھذه اﻟﺷﮭﺎدة ﯾرﺟﻰ زﯾﺎرة ﻣوﻗﻊ ﺟودة اﻹﻟﻛﺗروﻧﻲ‬

https://jawdah.qcc.abudhabi.ae/en/pages/homepage.aspx https://jawdah.qcc.abudhabi.ae/en/Pages/homepage.aspx

Any changes or modification on this certificate will affect its validity ‫أي ﻛﺷط أو ﺗﻐﯾﯾر ﻓﻲ ھذه اﻟﺷﮭﺎدة ﯾﻠﻐﯾﮭﺎ‬

Page 3 of 3
COMPLIANCE STATEMENT
PROJECT JUDICIAL INSTITUTION BUILDING - MINISTRY OF JUSTICE Date May 22, 2024
CLIENT M/S. MINISTRY OF ENERGY & INFRASTRUCTURE SKM REF # UQA102524
CONSULTANT M/S. ALTORATH INTERNATIONAL REVISION 00
CONTRACTOR M/S. Al AUSUS AL ARBAA GEN CONT .CO .L.L.C

Clause SPECIFICATIONS COMPLIANCE REMARKS

PART 1 - GENERAL
RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Noted
Conditions and Division 01 Specification Sections, apply to this Section.
1.01- SUMMARY
All units shall be selected after considering the height difference between the condensing unit and
evaporator units. Liquid and suction lines shall be suitably sized after considering the loss in
Noted
capacity due to height difference between the considering unit
and evaporator unit.
PART 2 –PRODUCTS
The outside of the outer skin shall be plastic coated to a thickness of 0.2 MM for additional protection.
Inside and outside of panel walls shall be completely smooth.
The sound absorption through the panel shall be according to DIN 52210-03 Rw = 42 dB. The sound
reduction through the panel required shall conform to
the values below for the various panel metal thicknesses. Noted
Thick HZ HZ HZ HZ HZ HZ HZ HZ dB VZ/VZ 63 125 250 500 1000 2000 4000 8000 Rw
1.0/0.6 15 15 33.5 41 42.5 39 37 37 36
1.5/0.8 15 23.5 34.5 39 45 46.5 45.5 45 42
1.5/1.0 15 22.5 34.5 44.5 47.5 52 56 56 45
(Rw) weighted sound reduction factor, calculated as DIN 52210
Noted
Panel thickness (VZ/VZ) IN/OUT in MM
Panels shall be assembled with special rivets. The inspection side of the coil section panels shall Casing shall be made of hot dip galvanized (zinc coated),
be assembled with bolts and nuts for easy removal of coils. Panel air tightness and sections upto phosphatized steel sheets which are then electrostatically
2500 Pa as required in polyester powder coated to provide an extremely tough,
EUROVENT 2/2. scratch resistance & excellent anti-corrosive protection.
Comply as per Remarks
Casing shall pass1000 hours in 5% salt spray testing at 95°F
(35°C) & 95% relative humidity as per ASTM B117
Unit casing shall be provided with access panels for easy
service and maintenance of all unit parts.
The base frame of the units shall be made from sendzimir galvanized sheet metal for size with
largest dimensions up to 2500 MM, and hot dip galvanized
U-profile for larger units. Service doors shall be provided with special gasket and locking device.
Access doors 400MM and larger shall be provided with hinges and handles for external and
Comply Access door removal type will be provided
internal opening. Access doors with width smaller than 400 MM shall be removable type fitted with
quick release flap turn lock with spring pressure arrangement. Sealant between panels
shall be a anti fungicide sealant material. The contractor to consider the marine light inside the
cabinet as per manufacturer’s recommendations.

UQA103161 May 22, 2024 Rev. 00 1


PROJECT JUDICIAL INSTITUTION BUILDING - MINISTRY OF JUSTICE Date May 22, 2024
CLIENT M/S. MINISTRY OF ENERGY & INFRASTRUCTURE SKM REF # UQA102524
CONSULTANT M/S. ALTORATH INTERNATIONAL REVISION 00
CONTRACTOR M/S. Al AUSUS AL ARBAA GEN CONT .CO .L.L.C

Clause SPECIFICATIONS COMPLIANCE REMARKS

All Roof Package are to be fitted with weather hoods and with sand trap Sand trap will be on duct (contractor scope), weather
1.02-01
hoods not applicable for package.
louvers and insect screen for FA intake.
Drain pans shall be stainless steel either integrated in the insulated base or
1.02-02 placed under the coil within the coil section. Drain pans shall have drain connection to the service Comply
side.
The Package manufacturer shall guarantee that no condensation shall take
place on the exterior of panels. In the event that any condensation problems appear after
installation, the Contractor shall undertake all remedial measures to rectify and to the satisfaction of Noted
the Consultant. Any stacked or double height coils shall have separate drain pans to reduce carry over,
such pans will be piped to the main drain, not into the lower pan.
Fans and shafts shall operate well below their critical speeds. Each shaft assembly shall be
statically and dynamically balanced before shipment from the manufacturer. If any out-of-balance
1.02-03 is apparent on site the Consultant reserves the right to require new factory supplied units to be
Noted
provided until satisfactory balance is demonstrated.
The Package unit shall have internal vibration isolation system for mounting
1.02-04 Comply as per remarks Comply with rubber isolators
fan, motor and drive assembly on spring isolators
Fan bearing shall be re-lubricated type with extended lube lines to terminate
outside the fan section. The bearing shall be selected for life of 200,000 Hours operation (fan
manufacturer shall certify that the bearing selected for the particular duty shall be theoretically
Comply
suitable for this duration of operation).
Fan drive shall be rated at 150% of the maximum motor power of the units and shall be fitted
with adjustable belt tension arrangement.
1.02-05 Filters:
Filter cells shall be of standard sizes and shall be easily obtainable from standard suppliers. Flat Filter Section incorporating 1” (25mm) thick is provided
as standard and 2” (50mm) thick flter having an average
Comply resistance efficiency of 54% as per ASHRAE Standard 52.1 or
equivalent
can be provided as an option.
Cooling coils shall be fabricated from ½” OD copper tubing of 0.41mm Evaporator coil shall be constructed of Hi-X copper tubes
thickness expanded into 0.12mm thick Aluminum fins. Return bends shall be die formed. All joints shall 3/8” OD mechanically bonded to aluminum (copper)
be silver brazed. corrugated fns
with maximum 14 fpi (1.8mm) spacing. Coil consists of
1.02-06 Comply as per Remarks headers of seamless copper tubing, thermostatic expansion
valve(s) & multi- circuited distributor(s). These coils shall be
tested against leakage by high air pressure
450psig(3100kPa) under water, cleaned & dehydrated at the
factory. Coil shall conform to AHRI-410.

UQA103161 May 22, 2024 Rev. 00 2


PROJECT JUDICIAL INSTITUTION BUILDING - MINISTRY OF JUSTICE Date May 22, 2024
CLIENT M/S. MINISTRY OF ENERGY & INFRASTRUCTURE SKM REF # UQA102524
CONSULTANT M/S. ALTORATH INTERNATIONAL REVISION 00
CONTRACTOR M/S. Al AUSUS AL ARBAA GEN CONT .CO .L.L.C

Clause SPECIFICATIONS COMPLIANCE REMARKS

Direct expansion type coils shall have headers of heavy section seamless copper tubing with a brass /
Comply Comply with R410A
copper distributor. Refrigerant shall be R407c or R410a.
The coil shall be tested to 21 bar and designed to operate at 16 bar NP. Maximum coil face velocity shall
Comply Droplet moisture. Eliminators N/A
not exceed 2.5 m/s. Droplet moisture eliminators shall be fitted to all Package unit cooling coils.
1.02-07- COMPERSOR AND RELATED ITEMS
Unit compressor shall be Rotary for split unit and scroll type for package, welded fully hermetic
with crankcase heater and suitable vibration isolators
and compressor motor shall be cooled by suction gas. The standard unit shall be capable of operating to Comply with scroll compressors
Comply as per remarks
the outside design temperature (115 deg .F). Rest is comply
Evaporator and condenser coils shall be of non-ferrous construction with
plate aluminum fins mechanically bonded to seamless copper tubes with all joints brazed.
Each A/C unit (indoor unit) shall be provided with Thermal Expansion Valve
(TXV) and solenoid valve before the TXV interlocked with the compressor
operation. Accumulator or any other fixed orifice refrigerant metering device will not be accepted
Comply
(only TXV will be accepted).
The same applies for all ducted split and package units from 1 TR capacity to 100 TR capacities without
any exception.
Ducted split of capacity up to and including 5 TR (actual) shall be direct
driven with 3 speeds motor. The ducted split unit shall be able to satisfy the sensible load as the latent
load. Hence the Grand Sensible Heat Ratio GSHR shall not be more than 5% over the values given Comply
in the schedule of
equipment’s, considering that the sensible or total capacity in the schedule of equipment’s.
The off coil of the ducted split units (when compressor working) shall not be more than (55/54
Comply
db/wb deg.F) at the medium speed of the proposed units.
The ducted split A/C units shall be equipped with the following devices and
accessories:
Sight glass with moisture indicator are contractor scope,
a) Height pressure cutout
Anti-freeze protection not applicable
b) Low pressure cutout Comply
c) Anti-freeze protection
Rest is comply
d) Filter drier
e) Sight glass with moisture indicator
For units capacity more than 5 tones, a time delay switch to prevent restarting the units
frequently.
NA Selected units are less than 5 TR
f) Thermal Expansion valve TXV
g) Solenoid valve
- Each ducted split/single package A/C unit shall be provided with electronic
type thermostat with digital display showing the actual space temperature in deg. C. When the Comply
temperature adjusting bottom is pressed the LCD shall show the set point.

UQA103161 May 22, 2024 Rev. 00 3


PROJECT JUDICIAL INSTITUTION BUILDING - MINISTRY OF JUSTICE Date May 22, 2024
CLIENT M/S. MINISTRY OF ENERGY & INFRASTRUCTURE SKM REF # UQA102524
CONSULTANT M/S. ALTORATH INTERNATIONAL REVISION 00
CONTRACTOR M/S. Al AUSUS AL ARBAA GEN CONT .CO .L.L.C

Clause SPECIFICATIONS COMPLIANCE REMARKS

The thermostat shall have FAN-AUTO-OFF switch. Thermostat shall be white


Noted
colour plastic, subject to Architect, and shall be located at the same height of the light switch.
- EER to be as referred in the drawings to be matched with Pearl-01. Noted
1.02-08- PACKAGE UNIT SEQUENCE OPERATION

Not applicable for Humidity control since application is not


NA
for swimming pool.

Not applicable for Humidity control since application is not


NA
for swimming pool.

UQA103161 May 22, 2024 Rev. 00 4


PROJECT JUDICIAL INSTITUTION BUILDING - MINISTRY OF JUSTICE Date May 22, 2024
CLIENT M/S. MINISTRY OF ENERGY & INFRASTRUCTURE SKM REF # UQA102524
CONSULTANT M/S. ALTORATH INTERNATIONAL REVISION 00
CONTRACTOR M/S. Al AUSUS AL ARBAA GEN CONT .CO .L.L.C

Clause SPECIFICATIONS COMPLIANCE REMARKS

Not applicable for Humidity control since application is not


NA
for swimming pool.

Not applicable for Humidity control since application is not


NA
for swimming pool.

Not applicable for Humidity control since application is not


NA
for swimming pool.

Not applicable for Humidity control since application is not


NA
for swimming pool.

UQA103161 May 22, 2024 Rev. 00 5


PROJECT JUDICIAL INSTITUTION BUILDING - MINISTRY OF JUSTICE Date May 22, 2024
CLIENT M/S. MINISTRY OF ENERGY & INFRASTRUCTURE SKM REF # UQA102524
CONSULTANT M/S. ALTORATH INTERNATIONAL REVISION 00
CONTRACTOR M/S. Al AUSUS AL ARBAA GEN CONT .CO .L.L.C

Clause SPECIFICATIONS COMPLIANCE REMARKS

Not applicable for Humidity control since application is not


NA
for swimming pool.

Not applicable for Humidity control since application is not


NA
for swimming pool.

Not applicable for Humidity control since application is not


NA
for swimming pool.

UQA103161 May 22, 2024 Rev. 00 6


PROJECT JUDICIAL INSTITUTION BUILDING - MINISTRY OF JUSTICE Date May 22, 2024
CLIENT M/S. MINISTRY OF ENERGY & INFRASTRUCTURE SKM REF # UQA102524
CONSULTANT M/S. ALTORATH INTERNATIONAL REVISION 00
CONTRACTOR M/S. Al AUSUS AL ARBAA GEN CONT .CO .L.L.C

Clause SPECIFICATIONS COMPLIANCE REMARKS

Not applicable for Humidity control since application is not


for swimming pool.

Not applicable for Humidity control since application is not


for swimming pool.

Not applicable for Humidity control since application is not


for swimming pool.

PART 3 EXCECUTION Contractor Scope


END OF SECTION

UQA103161 May 22, 2024 Rev. 00 7


TECHNICAL DATA SHEET
PROJECT: JUDICIAL INSTITUTION BUILDING - MINISTRY OF JUSTICE

CONTRACTOR NAME Al AUSUS AL ARBAA GEN CONT .CO .L.L.C.

Technical Data Sheett

SPECIFIED PROPOSED

Air Flow T Capacity S CAPACITY AIR FLOW


REF TYPE T Capacity Tr S Capacity QTY MODEL TYPE QTY MAX PI/Unit (KW) ON COIL °C AMBIENT °C Power Supply Dimensions (WxDxH)
L/S KW KW L/S

PAK01 Package 32.6 24.9 1788 1 APMR51130G1 Package 1 31.39 25.56 1900 16.2 24/17.3 46 380-415/3/50 1905X1905X1578

PAK02 Package 40.6 31.9 2300 1 APMR52170G1 Package 1 39.86 31.63 2300 19.1 24/17.3 46 380-415/3/50 2311X2235X1578

PAK03 Package 37.5 28.1 2160 1 APMR52170G1 Package 1 39.28 28.51 2260 19.1 22.2/16.7 46 380-415/3/50 2311X2235X1578

PAK04 Package 46 35.7 2539 1 APMR52210G1 Package 1 48.62 36.96 2539 23.9 24/17.2 46 380-415/3/50 2311X2235X1578

PAK05A&B Package 47.7 37.5 2597 2 APMR52210G1 Package 2 48.49 37.6 2597 23.9 24/17.1 46 380-415/3/50 2311X2235X1578

PAK06A&B Package 45.7 35.9 2513 2 APMR52210G1 Package 2 48.35 37.04 2513 23.9 24/17.1 46 380-415/3/50 2311X2235X1578

PAK07 Package 33.1 25.3 1791 1 APMR52150G1 Package 1 35.3 27.09 1891 17.7 24/17.3 46 380-415/3/50 1905X1905X1578

PAK08 Package 42.6 42.6 1933 1 APMR52180G1 Package 1 47.62 47.62 2200 22.3 38.4/21.8 46 380-415/3/50 2311X2235X1578

DSU-01 DX FAN COIL 3.3 3.1 231 2 RXVPG18 +DDPPG18 DX FAN COIL 2 5.5 2.3 276 2.05 23.8/16.6 46 220~240,50,1 838 x 703 x 381 / 635 ×635 ×903

NOTE :

* MCA/MFA values given in the catalogue electrical data should be referred for the same

* FOR MORE DETAILS REFER THE ATTACH SELECTION & CATALOGUE

22/05/2024 REV. 0
PAC/2024/R2
PACKAGED AIR CONDITIONERS
May, 2024
APMR52130G1 Bulletin # 224/2022

Unit Tag Prepared By BILELKACEM


Customer Reference

Project Print Date Tuesday, 21 May, 2024

INPUT DATA

Required Capacity - Leaving Wet Bulb Temperature - Altitude 0m

Return Air Flow Rate 1900 l/s Return Air DBT / WBT / RH 24 °C / 17.3 °C / 51% Ambient Temperature 46 °C

Fresh Air Flow Rate - Fresh Air DBT / WBT / RH - Quantity 1

PERFORMANCE DATA

Calculated Capacity * 31.39 kW Compressor Power Input 10.58 kW


Sensible Capacity * 25.56 kW Sensible Heat Ratio 0.81
Entering Air Flow Rate 1900 l/s Air Face Velocity 1.53 m/s

Entering Air DBT / WBT / RH 24 °C / 17.3 °C / 51% EER @ AHRI Conditions 7.5
Leaving Air DBT / WBT / RH 12.91 °C / 12.36 °C / 94%

Air Pressure drop through Evap. Coil 47 Pa

* Capacity given is gross capacity which does not include the effect of evaporator fan motor heat .

PHYSICAL DATA

CONDENSER

Compressor Type Scroll Refrigerant R-410A Fan Code / Quantity K-710 / 2

Compressor Model ZP067 Quantity 2 Motor Size / Quantity 0.8 kW / 2

Rows / Fin Spacing 2 / 1.6 mm Coil Face Area 3.47 m² Fin Material Aluminum fins

EVAPORATOR
Coil Size (H x L) 813 mm x 1524 mm Rows / Fin Spacing 4 / 2.1 mm Fin Material Aluminum fins

External Static Pressure 200 Pa Total Static Pressure 274 Pa Motor Size 1.1 kW

Fan Model SYT 12-12 / 2 (Non Standard motor size, please consult SKM)

Rotational Speed 877 rpm

OCTAVE BAND IN-DUCT SOUND POWER LEVEL - SUPPLY FAN

Frequency Hz 63 125 250 500 1000 2000 4000 8000 Total

Lw dB 76.4 79.2 72.9 72.0 71.6 69.9 66.0 61.7 82.8

LwA dB(A) 50.4 63.2 64.3 68.8 71.6 71.1 67.1 60.6 76.6

ELECTRICAL DATA

Power Supply 380V-415V/3Ph/50Hz Cond. Fan Motor(each) FLA 2.2


Compressor Qty RLA LRA
Cond. Fan Motor(each) LRA 9
MCA 34 ZP067 (each) 2 12 74
Evap. Fan Motor FLA 2.3
MFA 50
Evap. Fan Motor LRA 15.9

Note :- • Power input mentioned here is at rated condition only, and should not be used for cable/fuse selection.
• MCA/MFA values given in the catalogue electrical data page should be refered for the same .
• For non standard units MCA/MFA values, please consult SKM engineering department.
• Evaporator motor electrical data is based on 4 poles, single speed.

SKM Air Conditioning LLC Email : [email protected]


P.O. Box: 6004, Sharjah, UAE Tel: +971 6 5143333 1 Visit us at: www.skmaircon.com
Fax: +971 6 5143300
PAC/2024/R2
PACKAGED AIR CONDITIONERS
May, 2024
APMR52130G1 Bulletin # 224/2022

Unit Tag Prepared By BILELKACEM


Customer Reference

Project Print Date Tuesday, 21 May, 2024

Drawings

Loading Points

Unit A1 A2 A3 A4 Total
kg 165 165 203 203 736

Sound Data
SOUND PRESSURE LEVEL in dBA ref 2x10-5 Pa in free field
SPECTRUM PER OCTAVE BAND dB(A)

63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Total

@ 1 meter 43.6 54.6 54.7 51.3 58.0 57.1 51.4 47.9 63.2

Note: Sound Pressure Level according to ISO 3744, full load operation at 95ºF (35ºC) ambient and 44ºF (6.7ºC) / 54ºF (12.2ºC) evaporator leaving and
entering water temperatures.

Options : -

SKM Air Conditioning LLC Email : [email protected]


P.O. Box: 6004, Sharjah, UAE Tel: +971 6 5143333 2 Visit us at: www.skmaircon.com
Fax: +971 6 5143300
PAC/2024/R2
PACKAGED AIR CONDITIONERS
May, 2024
APMR52170G1 Bulletin # 224/2022

Unit Tag Prepared By BILELKACEM


Customer Reference

Project Print Date Tuesday, 21 May, 2024

INPUT DATA

Required Capacity - Leaving Wet Bulb Temperature - Altitude 0m

Return Air Flow Rate 2300 l/s Return Air DBT / WBT / RH 24 °C / 17.3 °C / 51% Ambient Temperature 46 °C

Fresh Air Flow Rate - Fresh Air DBT / WBT / RH - Quantity 1

PERFORMANCE DATA

Calculated Capacity * 39.86 kW Compressor Power Input 13.25 kW


Sensible Capacity * 31.63 kW Sensible Heat Ratio 0.79
Entering Air Flow Rate 2300 l/s Air Face Velocity 1.59 m/s

Entering Air DBT / WBT / RH 24 °C / 17.3 °C / 51% EER @ AHRI Conditions 7.8
Leaving Air DBT / WBT / RH 12.66 °C / 12.09 °C / 94%

Air Pressure drop through Evap. Coil 51 Pa

* Capacity given is gross capacity which does not include the effect of evaporator fan motor heat .

PHYSICAL DATA

CONDENSER

Compressor Type Scroll Refrigerant R-410A Fan Code / Quantity K-710 / 2

Compressor Model ZP083 Quantity 2 Motor Size / Quantity 0.8 kW / 2

Rows / Fin Spacing 2 / 1.6 mm Coil Face Area 4.83 m² Fin Material Aluminum fins

EVAPORATOR
Coil Size (H x L) 813 mm x 1778 mm Rows / Fin Spacing 4 / 2.1 mm Fin Material Aluminum fins

External Static Pressure 200 Pa Total Static Pressure 279 Pa Motor Size 1.5 kW

Fan Model SYT 12-12 / 2 (Non Standard motor size, please consult SKM)

Rotational Speed 889 rpm

OCTAVE BAND IN-DUCT SOUND POWER LEVEL - SUPPLY FAN

Frequency Hz 63 125 250 500 1000 2000 4000 8000 Total

Lw dB 76.8 79.6 73.2 72.5 72.3 70.4 66.7 62.4 83.3

LwA dB(A) 50.8 63.6 64.6 69.3 72.3 71.6 67.8 61.3 77.2

ELECTRICAL DATA

Power Supply 380V-415V/3Ph/50Hz Cond. Fan Motor(each) FLA 2.2


Compressor Qty RLA LRA
Cond. Fan Motor(each) LRA 9
MCA 39 ZP083 (each) 2 14 101
Evap. Fan Motor FLA 3.2
MFA 63
Evap. Fan Motor LRA 24.5

Note :- • Power input mentioned here is at rated condition only, and should not be used for cable/fuse selection.
• MCA/MFA values given in the catalogue electrical data page should be refered for the same .
• For non standard units MCA/MFA values, please consult SKM engineering department.
• Evaporator motor electrical data is based on 4 poles, single speed.

SKM Air Conditioning LLC Email : [email protected]


P.O. Box: 6004, Sharjah, UAE Tel: +971 6 5143333 1 Visit us at: www.skmaircon.com
Fax: +971 6 5143300
PAC/2024/R2
PACKAGED AIR CONDITIONERS
May, 2024
APMR52170G1 Bulletin # 224/2022

Unit Tag Prepared By BILELKACEM


Customer Reference

Project Print Date Tuesday, 21 May, 2024

Drawings

Loading Points

Unit A1 A2 A3 A4 Total
kg 191 191 253 253 888

Sound Data
SOUND PRESSURE LEVEL in dBA ref 2x10-5 Pa in free field
SPECTRUM PER OCTAVE BAND dB(A)

63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Total

@ 1 meter 45.9 56.9 57.0 52.9 57.7 59.5 54.6 48.5 64.9

Note: Sound Pressure Level according to ISO 3744, full load operation at 95ºF (35ºC) ambient and 44ºF (6.7ºC) / 54ºF (12.2ºC) evaporator leaving and
entering water temperatures.

Options : -

SKM Air Conditioning LLC Email : [email protected]


P.O. Box: 6004, Sharjah, UAE Tel: +971 6 5143333 2 Visit us at: www.skmaircon.com
Fax: +971 6 5143300
PAC/2024/R2
PACKAGED AIR CONDITIONERS
May, 2024
APMR52170G1 Bulletin # 224/2022

Unit Tag Prepared By BILELKACEM


Customer Reference

Project Print Date Tuesday, 21 May, 2024

INPUT DATA

Required Capacity - Leaving Wet Bulb Temperature - Altitude 0m

Return Air Flow Rate 2260 l/s Return Air DBT / WBT / RH 22.2 °C / 16.7 °C / 58% Ambient Temperature 46 °C

Fresh Air Flow Rate - Fresh Air DBT / WBT / RH - Quantity 1

PERFORMANCE DATA

Calculated Capacity * 39.28 kW Compressor Power Input 13.22 kW


Sensible Capacity * 28.51 kW Sensible Heat Ratio 0.73
Entering Air Flow Rate 2260 l/s Air Face Velocity 1.56 m/s

Entering Air DBT / WBT / RH 22.2 °C / 16.7 °C / 58% EER @ AHRI Conditions 7.7
Leaving Air DBT / WBT / RH 11.8 °C / 11.34 °C / 95%

Air Pressure drop through Evap. Coil 49 Pa

* Capacity given is gross capacity which does not include the effect of evaporator fan motor heat .

PHYSICAL DATA

CONDENSER

Compressor Type Scroll Refrigerant R-410A Fan Code / Quantity K-710 / 2

Compressor Model ZP083 Quantity 2 Motor Size / Quantity 0.8 kW / 2

Rows / Fin Spacing 2 / 1.6 mm Coil Face Area 4.83 m² Fin Material Aluminum fins

EVAPORATOR
Coil Size (H x L) 813 mm x 1778 mm Rows / Fin Spacing 4 / 2.1 mm Fin Material Aluminum fins

External Static Pressure 200 Pa Total Static Pressure 276 Pa Motor Size 1.5 kW

Fan Model SYT 12-12 / 2 (Non Standard motor size, please consult SKM)

Rotational Speed 883 rpm

OCTAVE BAND IN-DUCT SOUND POWER LEVEL - SUPPLY FAN

Frequency Hz 63 125 250 500 1000 2000 4000 8000 Total

Lw dB 76.6 79.4 73.0 72.3 72.0 70.1 66.3 62.1 83.0

LwA dB(A) 50.6 63.4 64.4 69.1 72.0 71.3 67.4 61.0 76.9

ELECTRICAL DATA

Power Supply 380V-415V/3Ph/50Hz Cond. Fan Motor(each) FLA 2.2


Compressor Qty RLA LRA
Cond. Fan Motor(each) LRA 9
MCA 39 ZP083 (each) 2 14 101
Evap. Fan Motor FLA 3.2
MFA 63
Evap. Fan Motor LRA 24.5

Note :- • Power input mentioned here is at rated condition only, and should not be used for cable/fuse selection.
• MCA/MFA values given in the catalogue electrical data page should be refered for the same .
• For non standard units MCA/MFA values, please consult SKM engineering department.
• Evaporator motor electrical data is based on 4 poles, single speed.

SKM Air Conditioning LLC Email : [email protected]


P.O. Box: 6004, Sharjah, UAE Tel: +971 6 5143333 1 Visit us at: www.skmaircon.com
Fax: +971 6 5143300
PAC/2024/R2
PACKAGED AIR CONDITIONERS
May, 2024
APMR52170G1 Bulletin # 224/2022

Unit Tag Prepared By BILELKACEM


Customer Reference

Project Print Date Tuesday, 21 May, 2024

Drawings

Loading Points

Unit A1 A2 A3 A4 Total
kg 191 191 253 253 888

Sound Data
SOUND PRESSURE LEVEL in dBA ref 2x10-5 Pa in free field
SPECTRUM PER OCTAVE BAND dB(A)

63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Total

@ 1 meter 45.9 56.9 57.0 52.9 57.7 59.5 54.6 48.5 64.9

Note: Sound Pressure Level according to ISO 3744, full load operation at 95ºF (35ºC) ambient and 44ºF (6.7ºC) / 54ºF (12.2ºC) evaporator leaving and
entering water temperatures.

Options : -

SKM Air Conditioning LLC Email : [email protected]


P.O. Box: 6004, Sharjah, UAE Tel: +971 6 5143333 2 Visit us at: www.skmaircon.com
Fax: +971 6 5143300
PAC/2024/R2
PACKAGED AIR CONDITIONERS
May, 2024
APMR52210G1 Bulletin # 224/2022

Unit Tag Prepared By BILELKACEM


Customer Reference

Project Print Date Tuesday, 21 May, 2024

INPUT DATA

Required Capacity - Leaving Wet Bulb Temperature - Altitude 0m

Return Air Flow Rate 2539 l/s Return Air DBT / WBT / RH 24 °C / 17.2 °C / 51% Ambient Temperature 46 °C

Fresh Air Flow Rate - Fresh Air DBT / WBT / RH - Quantity 1

PERFORMANCE DATA

Calculated Capacity * 48.62 kW Compressor Power Input 16.21 kW


Sensible Capacity * 36.96 kW Sensible Heat Ratio 0.76
Entering Air Flow Rate 2539 l/s Air Face Velocity 1.76 m/s

Entering Air DBT / WBT / RH 24 °C / 17.2 °C / 51% EER @ AHRI Conditions 8


Leaving Air DBT / WBT / RH 12 °C / 11.35 °C / 93%

Air Pressure drop through Evap. Coil 62 Pa

* Capacity given is gross capacity which does not include the effect of evaporator fan motor heat .

PHYSICAL DATA

CONDENSER

Compressor Type Scroll Refrigerant R-410A Fan Code / Quantity K-710 / 2

Compressor Model ZP103 Quantity 2 Motor Size / Quantity 0.8 kW / 2

Rows / Fin Spacing 3 / 1.6 mm Coil Face Area 4.83 m² Fin Material Aluminum fins

EVAPORATOR
Coil Size (H x L) 813 mm x 1778 mm Rows / Fin Spacing 4 / 2.1 mm Fin Material Aluminum fins

External Static Pressure 200 Pa Total Static Pressure 296 Pa Motor Size 2.2 kW

Fan Model SYT 12-12 / 2 (Non Standard motor size, please consult SKM)

Rotational Speed 920 rpm

OCTAVE BAND IN-DUCT SOUND POWER LEVEL - SUPPLY FAN

Frequency Hz 63 125 250 500 1000 2000 4000 8000 Total

Lw dB 77.6 80.4 74.3 74.0 73.9 72.0 68.5 64.1 84.3

LwA dB(A) 51.6 64.4 65.7 70.8 73.9 73.2 69.6 63.0 78.8

ELECTRICAL DATA

Power Supply 380V-415V/3Ph/50Hz Cond. Fan Motor(each) FLA 2.2


Compressor Qty RLA LRA
Cond. Fan Motor(each) LRA 9
MCA 52 ZP103 (each) 2 19 111
Evap. Fan Motor FLA 4.6
MFA 80
Evap. Fan Motor LRA 37

Note :- • Power input mentioned here is at rated condition only, and should not be used for cable/fuse selection.
• MCA/MFA values given in the catalogue electrical data page should be refered for the same .
• For non standard units MCA/MFA values, please consult SKM engineering department.
• Evaporator motor electrical data is based on 4 poles, single speed.

SKM Air Conditioning LLC Email : [email protected]


P.O. Box: 6004, Sharjah, UAE Tel: +971 6 5143333 1 Visit us at: www.skmaircon.com
Fax: +971 6 5143300
PAC/2024/R2
PACKAGED AIR CONDITIONERS
May, 2024
APMR52210G1 Bulletin # 224/2022

Unit Tag Prepared By BILELKACEM


Customer Reference

Project Print Date Tuesday, 21 May, 2024

Drawings

Loading Points

Unit A2 A3 A4 A1 Total
kg 220 254 254 220 948

Sound Data
SOUND PRESSURE LEVEL in dBA ref 2x10-5 Pa in free field
SPECTRUM PER OCTAVE BAND dB(A)

63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Total

@ 1 meter 47.1 58.1 58.1 56.1 57.4 62.7 56.3 48.3 66.7

Note: Sound Pressure Level according to ISO 3744, full load operation at 95ºF (35ºC) ambient and 44ºF (6.7ºC) / 54ºF (12.2ºC) evaporator leaving and
entering water temperatures.

Options : -

SKM Air Conditioning LLC Email : [email protected]


P.O. Box: 6004, Sharjah, UAE Tel: +971 6 5143333 2 Visit us at: www.skmaircon.com
Fax: +971 6 5143300
PAC/2024/R2
PACKAGED AIR CONDITIONERS
May, 2024
APMR52210G1 Bulletin # 224/2022

Unit Tag Prepared By BILELKACEM


Customer Reference

Project Print Date Tuesday, 21 May, 2024

INPUT DATA

Required Capacity - Leaving Wet Bulb Temperature - Altitude 0m

Return Air Flow Rate 2597 l/s Return Air DBT / WBT / RH 24 °C / 17.1 °C / 50% Ambient Temperature 46 °C

Fresh Air Flow Rate - Fresh Air DBT / WBT / RH - Quantity 1

PERFORMANCE DATA

Calculated Capacity * 48.49 kW Compressor Power Input 16.21 kW


Sensible Capacity * 37.6 kW Sensible Heat Ratio 0.78
Entering Air Flow Rate 2597 l/s Air Face Velocity 1.8 m/s

Entering Air DBT / WBT / RH 24 °C / 17.1 °C / 50% EER @ AHRI Conditions 7.9
Leaving Air DBT / WBT / RH 12.06 °C / 11.39 °C / 93%

Air Pressure drop through Evap. Coil 65 Pa

* Capacity given is gross capacity which does not include the effect of evaporator fan motor heat .

PHYSICAL DATA

CONDENSER

Compressor Type Scroll Refrigerant R-410A Fan Code / Quantity K-710 / 2

Compressor Model ZP103 Quantity 2 Motor Size / Quantity 0.8 kW / 2

Rows / Fin Spacing 3 / 1.6 mm Coil Face Area 4.83 m² Fin Material Aluminum fins

EVAPORATOR
Coil Size (H x L) 813 mm x 1778 mm Rows / Fin Spacing 4 / 2.1 mm Fin Material Aluminum fins

External Static Pressure 200 Pa Total Static Pressure 301 Pa Motor Size 2.2 kW

Fan Model SYT 12-12 / 2 (Non Standard motor size, please consult SKM)

Rotational Speed 928 rpm

OCTAVE BAND IN-DUCT SOUND POWER LEVEL - SUPPLY FAN

Frequency Hz 63 125 250 500 1000 2000 4000 8000 Total

Lw dB 77.8 80.7 74.6 74.3 74.3 72.4 68.9 64.5 84.6

LwA dB(A) 51.8 64.7 66.0 71.1 74.3 73.6 70.0 63.4 79.1

ELECTRICAL DATA

Power Supply 380V-415V/3Ph/50Hz Cond. Fan Motor(each) FLA 2.2


Compressor Qty RLA LRA
Cond. Fan Motor(each) LRA 9
MCA 52 ZP103 (each) 2 19 111
Evap. Fan Motor FLA 4.6
MFA 80
Evap. Fan Motor LRA 37

Note :- • Power input mentioned here is at rated condition only, and should not be used for cable/fuse selection.
• MCA/MFA values given in the catalogue electrical data page should be refered for the same .
• For non standard units MCA/MFA values, please consult SKM engineering department.
• Evaporator motor electrical data is based on 4 poles, single speed.

SKM Air Conditioning LLC Email : [email protected]


P.O. Box: 6004, Sharjah, UAE Tel: +971 6 5143333 1 Visit us at: www.skmaircon.com
Fax: +971 6 5143300
PAC/2024/R2
PACKAGED AIR CONDITIONERS
May, 2024
APMR52210G1 Bulletin # 224/2022

Unit Tag Prepared By BILELKACEM


Customer Reference

Project Print Date Tuesday, 21 May, 2024

Drawings

Loading Points

Unit A2 A3 A4 A1 Total
kg 220 254 254 220 948

Sound Data
SOUND PRESSURE LEVEL in dBA ref 2x10-5 Pa in free field
SPECTRUM PER OCTAVE BAND dB(A)

63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Total

@ 1 meter 47.1 58.1 58.1 56.1 57.4 62.7 56.3 48.3 66.7

Note: Sound Pressure Level according to ISO 3744, full load operation at 95ºF (35ºC) ambient and 44ºF (6.7ºC) / 54ºF (12.2ºC) evaporator leaving and
entering water temperatures.

Options : -

SKM Air Conditioning LLC Email : [email protected]


P.O. Box: 6004, Sharjah, UAE Tel: +971 6 5143333 2 Visit us at: www.skmaircon.com
Fax: +971 6 5143300
PAC/2024/R2
PACKAGED AIR CONDITIONERS
May, 2024
APMR52210G1 Bulletin # 224/2022

Unit Tag Prepared By BILELKACEM


Customer Reference

Project Print Date Tuesday, 21 May, 2024

INPUT DATA

Required Capacity - Leaving Wet Bulb Temperature - Altitude 0m

Return Air Flow Rate 2513 l/s Return Air DBT / WBT / RH 24 °C / 17.1 °C / 50% Ambient Temperature 46 °C

Fresh Air Flow Rate - Fresh Air DBT / WBT / RH - Quantity 1

PERFORMANCE DATA

Calculated Capacity * 48.35 kW Compressor Power Input 16.2 kW


Sensible Capacity * 37.04 kW Sensible Heat Ratio 0.77
Entering Air Flow Rate 2513 l/s Air Face Velocity 1.74 m/s

Entering Air DBT / WBT / RH 24 °C / 17.1 °C / 50% EER @ AHRI Conditions 7.9
Leaving Air DBT / WBT / RH 11.85 °C / 11.2 °C / 93%

Air Pressure drop through Evap. Coil 61 Pa

* Capacity given is gross capacity which does not include the effect of evaporator fan motor heat .

PHYSICAL DATA

CONDENSER

Compressor Type Scroll Refrigerant R-410A Fan Code / Quantity K-710 / 2

Compressor Model ZP103 Quantity 2 Motor Size / Quantity 0.8 kW / 2

Rows / Fin Spacing 3 / 1.6 mm Coil Face Area 4.83 m² Fin Material Aluminum fins

EVAPORATOR
Coil Size (H x L) 813 mm x 1778 mm Rows / Fin Spacing 4 / 2.1 mm Fin Material Aluminum fins

External Static Pressure 200 Pa Total Static Pressure 294 Pa Motor Size 2.2 kW

Fan Model SYT 12-12 / 2 (Non Standard motor size, please consult SKM)

Rotational Speed 916 rpm

OCTAVE BAND IN-DUCT SOUND POWER LEVEL - SUPPLY FAN

Frequency Hz 63 125 250 500 1000 2000 4000 8000 Total

Lw dB 77.5 80.3 74.2 73.8 73.7 71.9 68.3 64.0 84.2

LwA dB(A) 51.5 64.3 65.6 70.6 73.7 73.1 69.4 62.9 78.6

ELECTRICAL DATA

Power Supply 380V-415V/3Ph/50Hz Cond. Fan Motor(each) FLA 2.2


Compressor Qty RLA LRA
Cond. Fan Motor(each) LRA 9
MCA 52 ZP103 (each) 2 19 111
Evap. Fan Motor FLA 4.6
MFA 80
Evap. Fan Motor LRA 37

Note :- • Power input mentioned here is at rated condition only, and should not be used for cable/fuse selection.
• MCA/MFA values given in the catalogue electrical data page should be refered for the same .
• For non standard units MCA/MFA values, please consult SKM engineering department.
• Evaporator motor electrical data is based on 4 poles, single speed.

SKM Air Conditioning LLC Email : [email protected]


P.O. Box: 6004, Sharjah, UAE Tel: +971 6 5143333 1 Visit us at: www.skmaircon.com
Fax: +971 6 5143300
PAC/2024/R2
PACKAGED AIR CONDITIONERS
May, 2024
APMR52210G1 Bulletin # 224/2022

Unit Tag Prepared By BILELKACEM


Customer Reference

Project Print Date Tuesday, 21 May, 2024

Drawings

Loading Points

Unit A2 A3 A4 A1 Total
kg 220 254 254 220 948

Sound Data
SOUND PRESSURE LEVEL in dBA ref 2x10-5 Pa in free field
SPECTRUM PER OCTAVE BAND dB(A)

63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Total

@ 1 meter 47.1 58.1 58.1 56.1 57.4 62.7 56.3 48.3 66.7

Note: Sound Pressure Level according to ISO 3744, full load operation at 95ºF (35ºC) ambient and 44ºF (6.7ºC) / 54ºF (12.2ºC) evaporator leaving and
entering water temperatures.

Options : -

SKM Air Conditioning LLC Email : [email protected]


P.O. Box: 6004, Sharjah, UAE Tel: +971 6 5143333 2 Visit us at: www.skmaircon.com
Fax: +971 6 5143300
PAC/2024/R2
PACKAGED AIR CONDITIONERS
May, 2024
APMR52150G1 Bulletin # 224/2022

Unit Tag Prepared By BILELKACEM


Customer Reference

Project Print Date Tuesday, 21 May, 2024

INPUT DATA

Required Capacity - Leaving Wet Bulb Temperature - Altitude 0m

Return Air Flow Rate 1891 l/s Return Air DBT / WBT / RH 24 °C / 17.3 °C / 51% Ambient Temperature 46 °C

Fresh Air Flow Rate - Fresh Air DBT / WBT / RH - Quantity 1

PERFORMANCE DATA

Calculated Capacity * 35.3 kW Compressor Power Input 12.17 kW


Sensible Capacity * 27.09 kW Sensible Heat Ratio 0.77
Entering Air Flow Rate 1891 l/s Air Face Velocity 1.53 m/s

Entering Air DBT / WBT / RH 24 °C / 17.3 °C / 51% EER @ AHRI Conditions 7.6
Leaving Air DBT / WBT / RH 12.19 °C / 11.64 °C / 94%

Air Pressure drop through Evap. Coil 47 Pa

* Capacity given is gross capacity which does not include the effect of evaporator fan motor heat .

PHYSICAL DATA

CONDENSER

Compressor Type Scroll Refrigerant R-410A Fan Code / Quantity K-710 / 2

Compressor Model ZP076KCE Quantity 2 Motor Size / Quantity 0.8 kW / 2

Rows / Fin Spacing 2 / 1.6 mm Coil Face Area 3.47 m² Fin Material Aluminum fins

EVAPORATOR
Coil Size (H x L) 813 mm x 1524 mm Rows / Fin Spacing 4 / 2.1 mm Fin Material Aluminum fins

External Static Pressure 200 Pa Total Static Pressure 273 Pa Motor Size 1.1 kW

Fan Model SYT 12-12 / 2 (Non Standard motor size, please consult SKM)

Rotational Speed 875 rpm

OCTAVE BAND IN-DUCT SOUND POWER LEVEL - SUPPLY FAN

Frequency Hz 63 125 250 500 1000 2000 4000 8000 Total

Lw dB 76.3 79.2 72.8 72.0 71.5 69.9 66.0 61.7 82.8

LwA dB(A) 50.3 63.2 64.2 68.8 71.5 71.1 67.1 60.6 76.6

ELECTRICAL DATA

Power Supply 380V-415V/3Ph/50Hz Cond. Fan Motor(each) FLA 2.2


Compressor Qty RLA LRA
Cond. Fan Motor(each) LRA 9
MCA 39 ZP076 (each) 2 14 100
Evap. Fan Motor FLA 2.3
MFA 63
Evap. Fan Motor LRA 15.9

Note :- • Power input mentioned here is at rated condition only, and should not be used for cable/fuse selection.
• MCA/MFA values given in the catalogue electrical data page should be refered for the same .
• For non standard units MCA/MFA values, please consult SKM engineering department.
• Evaporator motor electrical data is based on 4 poles, single speed.

SKM Air Conditioning LLC Email : [email protected]


P.O. Box: 6004, Sharjah, UAE Tel: +971 6 5143333 1 Visit us at: www.skmaircon.com
Fax: +971 6 5143300
PAC/2024/R2
PACKAGED AIR CONDITIONERS
May, 2024
APMR52150G1 Bulletin # 224/2022

Unit Tag Prepared By BILELKACEM


Customer Reference

Project Print Date Tuesday, 21 May, 2024

Drawings

Loading Points

Unit A1 A2 A3 A4 Total
kg 165 165 203 203 736

Sound Data
SOUND PRESSURE LEVEL in dBA ref 2x10-5 Pa in free field
SPECTRUM PER OCTAVE BAND dB(A)

63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Total

@ 1 meter 45.8 55.8 55.8 52.2 57.3 57.6 53.5 48.3 63.7

Note: Sound Pressure Level according to ISO 3744, full load operation at 95ºF (35ºC) ambient and 44ºF (6.7ºC) / 54ºF (12.2ºC) evaporator leaving and
entering water temperatures.

Options : -

SKM Air Conditioning LLC Email : [email protected]


P.O. Box: 6004, Sharjah, UAE Tel: +971 6 5143333 2 Visit us at: www.skmaircon.com
Fax: +971 6 5143300
PAC/2024/R2
PACKAGED AIR CONDITIONERS
May, 2024
APMR52180G1 Bulletin # 224/2022

Unit Tag Prepared By BILELKACEM


Customer Reference

Project Print Date Tuesday, 21 May, 2024

INPUT DATA

Required Capacity - Leaving Wet Bulb Temperature - Altitude 0m

Return Air Flow Rate 2200 l/s Return Air DBT / WBT / RH 38.4 °C / 21.8 °C / 23% Ambient Temperature 46 °C

Fresh Air Flow Rate - Fresh Air DBT / WBT / RH - Quantity 1

PERFORMANCE DATA

Calculated Capacity * 47.62 kW Compressor Power Input 14.79 kW


Sensible Capacity * 47.62 kW Sensible Heat Ratio 1
Entering Air Flow Rate 2200 l/s Air Face Velocity 1.52 m/s

Entering Air DBT / WBT / RH 38.4 °C / 21.8 °C / 23% EER @ AHRI Conditions 8.6
Leaving Air DBT / WBT / RH 20.55 °C / 16.32 °C / 65%

Air Pressure drop through Evap. Coil 47 Pa

* Capacity given is gross capacity which does not include the effect of evaporator fan motor heat .

PHYSICAL DATA

CONDENSER

Compressor Type Scroll Refrigerant R-410A Fan Code / Quantity K-710 / 2

Compressor Model ZP090 Quantity 2 Motor Size / Quantity 0.8 kW / 2

Rows / Fin Spacing 2 / 1.6 mm Coil Face Area 4.83 m² Fin Material Aluminum fins

EVAPORATOR
Coil Size (H x L) 813 mm x 1778 mm Rows / Fin Spacing 4 / 2.1 mm Fin Material Aluminum fins

External Static Pressure 200 Pa Total Static Pressure 273 Pa Motor Size 1.5 kW

Fan Model SYT 12-12 / 2 (Non Standard motor size, please consult SKM)

Rotational Speed 888 rpm

OCTAVE BAND IN-DUCT SOUND POWER LEVEL - SUPPLY FAN

Frequency Hz 63 125 250 500 1000 2000 4000 8000 Total

Lw dB 76.8 79.5 73.1 72.2 72.0 70.0 66.2 62.0 83.1

LwA dB(A) 50.8 63.5 64.5 69.0 72.0 71.2 67.3 60.9 76.9

ELECTRICAL DATA

Power Supply 380V-415V/3Ph/50Hz Cond. Fan Motor(each) FLA 2.2


Compressor Qty RLA LRA
Cond. Fan Motor(each) LRA 9
MCA 44 ZP090 (each) 2 16 95
Evap. Fan Motor FLA 3.2
MFA 63
Evap. Fan Motor LRA 24.5

Note :- • Power input mentioned here is at rated condition only, and should not be used for cable/fuse selection.
• MCA/MFA values given in the catalogue electrical data page should be refered for the same .
• For non standard units MCA/MFA values, please consult SKM engineering department.
• Evaporator motor electrical data is based on 4 poles, single speed.

SKM Air Conditioning LLC Email : [email protected]


P.O. Box: 6004, Sharjah, UAE Tel: +971 6 5143333 1 Visit us at: www.skmaircon.com
Fax: +971 6 5143300
PAC/2024/R2
PACKAGED AIR CONDITIONERS
May, 2024
APMR52180G1 Bulletin # 224/2022

Unit Tag Prepared By BILELKACEM


Customer Reference

Project Print Date Tuesday, 21 May, 2024

Drawings

Loading Points

Unit A1 A2 A3 A4 Total
kg 205 205 256 256 922

Sound Data
SOUND PRESSURE LEVEL in dBA ref 2x10-5 Pa in free field
SPECTRUM PER OCTAVE BAND dB(A)

63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Total

@ 1 meter 47.0 58.0 58.0 54.7 56.6 61.3 54.2 47.4 65.7

Note: Sound Pressure Level according to ISO 3744, full load operation at 95ºF (35ºC) ambient and 44ºF (6.7ºC) / 54ºF (12.2ºC) evaporator leaving and
entering water temperatures.

Options : -

SKM Air Conditioning LLC Email : [email protected]


P.O. Box: 6004, Sharjah, UAE Tel: +971 6 5143333 2 Visit us at: www.skmaircon.com
Fax: +971 6 5143300
PRODUCT CATALOGUE
APMRG1 Series R 22
REFRIGERANT

Packaged Air Conditioners

50Hz

Range 4.6 TR to 45.8 TR


R 22
(16.1 kW to REFRIGERANT
161.2 kW)

S.K.M Air Conditioning LLC


1
Contents Introduction
Legend ................................................. 2 Electrical Data ...................................... 14
Nomenclature ....................................... 2 Field Connection................................. 15
SKM APMRG1 New PackagedAir Conditioners
Introduction ......................................... 2 Typical Wiring Diagram ...................... 16 Series are designed and manufactured to meet
General Features ............................... 3 Dimensional Data .................................. 18 the requirements of Gulf’s severe climatic
Main Component Features .................. 3 Loading Points ....................................... 23 conditions and are built specifically for ducted
Optional Features ................................ 4 Recommended Clearances ................. 24 systems which will enable them to be installed
Engineering Specifications ...................7 Installation & Commissioning ............... 27 easily on roof tops or on the ground.
Capacity Ratings ................................ 10 Guide Specifications ............................. 28
Fan Performance ............................... 13 The APMRG1 series PackagedAir Conditioners
are compact, quiet, most efficient and self
contained units are ideal for commercial and
Legend top end residential applications.

The following legends are used throughout this manual: APMRG1 Series is also designed to perform as
per ESMA regulation to achieve high efficiency
AFR ................................... Air Flow Rate lbs......................................Pounds weight level in gulf conditions
BPF..................................By Pass Factor L/s.................................Liters per second
CFM.....................Cubic feet per minute MBh.....................................BTUHx1000
Available in 19 different sizes from 4.6 to 45.8
Pa..................................................Pascal
EER..................Energy Efficiency Ratio TR (16.1kW to 161.2kW) in 50 Hz at nominal
Ph....................................................Phase
ESP.................External Static Pressure AHRI conditions. APMRG1 series packaged
PI ......Power Input of Compressor in kW
Hz ....................................................Hertz RPM ...................Revolutions Per Minute air conditioners are designed to operate in a
in. wg...............................Inch water gauge RPS...........................Rated Power Supply wide ambient temperature range between 50°F
kW.............................................Kilowatts TR.............................Tons of Refrigeration (10°C) to 125°F (51.7°C), based on specific
V..........................................................Volts conditions & model applies. Two independent
kg........................................Kilogram
refrigeration circuits are provided where two
compressors are used.

APMRG1 series units from SKM are completely


Nomenclature assembled, leak tested, vacuumed, internally
wired and fully charged with R-410A refrigerant
A P M R - 5 1 050 G1 Y at factory. Each unit is fully factory tested
before dispatch and is ready for installation.
Air Cooled Power Supply Code All that is required on the site is to connect
Y : 380V-415/3Ph/50Hz ducts, drain lines, main power supply and field
Package
wiring to the thermostat. This greatly reduces
Scroll
Compressor G1 : High Efficiency the installation work and cost.

R-410A
SKM provides qualified service and stock
Nominal Capacity in MBh
5 = 50 Hz of replacement parts in all major cities of the
1 : Single Circuit G.C.C. countries, Egypt, Jordan, and Pakistan.
2 : Double Circuit See back cover for details or call SKM.

SKM Air Conditioning LLC

SKM reserves the right to change, in part or in


whole the specifications of its Air Conditioning
Equipment at any time in order to add the latest
technology. Therefore, the enclosed information
may change without any prior notice.

You name it.....We cool it


General Features Condenser Coils R 22
REFRIGERANT
The APMRG1 Series is a modern, diversified and environment Condenser coils are manufactured from Corrugated fin and Hi-X
friendly series of packaged air conditioners which use R-410A seamless copper tubes mechanically bonded to aluminium fins
refrigerant. to ensure optimum heat transfer. All coils are tested against
leakage by high air pressure 715psig (4930kPa) under water.
The APMRG1 Series Packaged Air Conditioners are yet another An integral subcooling circuit is incorporated in the lower section
new unique series from SKM incorporates many salient features of the condenser to increase system capacity. The additional
which, together, provides a heavy duty, robust, long lasting condenser surface provides more cooling using less energy at
commercial unit meant for high end residential and commercial no additional cost.
applications. The APMRG1 series models combine high efficiency
condenser and cooling coils, evaporator blower and heavy duty
Condenser Fans
motor in addition to premium safety and operational controls.
Condenser fans are propeller type with aluminum alloy blades
The complete APMRG1 packaged unit provides an extremely and are directly driven by electric motors. Motors are Totally
rugged, long life, energy efficient, self contained packaged air Enclosed Air Over (TEAO), six pole with Class F insulation and
conditioner that will provide cooling with higher efficiency over IP54/55 protection depending on models. Complete fan assembly
a long and extended life. is provided with fan guard.

What makes APMRG1 series yet another model in the top class
range of SKM products is the use of:
Evaporator
• High efficiency totally sealed scroll hermetic compressors. Evaporator coils are manufactured from Hi-X seamless copper
• Totally enclosed, Class F insulated,condenser and evaporator tubes mechanically bonded to aluminium Corrugated fins to
fan motors. ensure optimum heat transfer. All evaporator coils are tested
• Heavy duty condenser and evaporator coils optimised in against leakage by high air pressure of 450 psig (3100kPa) under
water. Coils conform to AHRI-410.
design for long-life maintenance free operation.
• Cabinet construction specifically designed for Gulf climates.
• Electronic control board for the unit operation.
• Typically, much heavier gauge tubing and thicker fins for Evaporator Fan & Drive
ruggedness and long life. Evaporator fans are forward curved centrifugal double inlet, double
width, statically and dynamically balanced. Bearings used in the
fans are self aligning and lubricated for life. Evaporator fans are
belt driven and use “V” belts with an adjustable variable pitch
motor pulley resulting in an accurate fan air flow adjustment.
Main Component Features
Fans are driven by Totally Enclosed, IP-55 Protected, 4 pole
The common standard features of all APMRG1 series packaged
Class F insulated electric motors. The motors are factory wired to
units include the following
the control panel where the motor starters are located to control
the operation of the motors. The motors conform to relevant IEC
Compressors standards.

Compressors used in APMRG1 packaged unit series are


hermetically sealed, compact scroll with the following features: Casing and Structure
• High Efficiency. The unit casing used in APMRG1 series is made of hot dip
galvanized (zinc coated) steel sheets, conforming to JIS-G
• Quiet operation, Low Sound levels.
3302 and ASTMA653, which is phosphatized and baked after an
• Compact and light.
electrostatic powder coat of approx. 60 microns. This finish and
• Limited wear. coating can pass a 1000 hour in 5% salt spray testing at 95°F
• 70% fewer moving parts than comparably sized reciprocating (35°C) and 95% relative humidity as per ASTM B117.
compressors.
• Unique ability to hadle liquid refrigerant. The evaporator section is insulated from all the sides with 1/2”
• Suction gas motor cooling. for model 51055G1 to 51120G1 & 1” for model 52130G1 to
• Suction screen. 52550G1 thick fiber glass insulation with extremely tough and
• Centrifugal oil pumps with filter and magnet. durable black composite surface. The insulation cum sound liner
• Brazed fittings or Rotalock options. meets the fire requirements of NFPA90A & 90B and is secured
• Two refrigerant circuits on larger units provides efficient with mechanical fasteners in addition to water resistant adhesive.
part load.
• No internal valves.

S.K.M Air Conditioning LLC


3
SKM Packaged Air Conditioners APMRG1 Series

Refrigerant R- 410A
Why 410A? Optional Features
R-410A has a higher volumetric cooling capacity compared to As with all SKM air conditioning units, the APMRG1 Series
R-22 and has better thermal exchange properties. This results Packaged Units are available with multitude of optional features
in overall performance gains in terms of system efficiency. The available on request:
greater density of the vapour in R-410A permits higher system
velocities, reduces pressure drop losses and allows smaller Double Skin Evaporator (DSE)
diameter tubing to be used. In other words a smaller unit can Double skin evaporator section with galvanized inner skin.
be developed using a smaller displacement compressor, less (For models 51055G1 up to 51120G1, please consult SKM)
coil and less refrigerant while maintaining system efficiencies
comparable to current day R-22 equipment.
Double Skin Insulation (DSI)
Inner skin in the evaporator section is provided with foam board
Benefits
insulation.
• No ozone depletion potential or phase-out date
Using chlorine-free R-410A with zero Ozone Depletion (For models 51055G1 up to 51120G1, please consult SKM)
Potential (ODP) helps protect both the environment and your
investment. That’s because new equipment using R-410A 1” (25mm) Thick Fiber Glass Insulation (1SG)
faces no mandated phase-out date over a 20 to 30 year Evaporator section with 1” thick fiber glass insulation.
equipment life expectancy.
(This option applicable for models 51055G1 up to 51120G1,
• Reduced service costs please consult SKM)
R-410A refrigerant has no significant “glide.” If a leak occurs,
only the lost refrigerant must be replaced. Temperature Based Economizer (ECRU)
Simple temperature based economizer.
Attention points
2” (50mm) Flat Filter Section (FSIP2)
• Pressure level: 1.6 times of R-22.
• Lubricating oil: Ester Oil absorb moisture easily For heavy filtration need a section can be provided without or
(Never mix with mineral oil). with aluminium cleanable filter.
• Tools exclusive for R-410A.
• Never mix R-410A with other refrigerant. Alternative Condenser Material
• Driers, valves and even copper tube must be approved for Made of copper tubes and alternative fin material and/or
use with R-410A. protective coating.
• Never allow refrigerant cylinders to exceed 60°C. • Pre Coated aluminum fins (FAP).
• Aluminum Fins with Aeris post Coat Protection (FAA).
• Copper Fins (FC).
Control Panel • Copper Fins with Aeris post Coat Protection (FCA).

The APMRG1 packaged Air Conditioners are provided with IP- Alternative Evaporator Material
54 control panel enclosure comprising all starting, operating &
safety controls. The panel is factory wired in accordance with NEC Made of copper tubes and alternative fin material and/or
430 & 440, labelled, tagged and features 220V / 240V controls. protective coating.
• Pre Coated aluminum fins (EFAP).
• Starting contactors for compressors and motors. • Aluminum Fins with Aeris post Coat Protection (EFAA).
• Internal overload protection for compressors. • Copper Fins (EFC).
• Copper Fins with Aeris post Coat Protectionn (EFCA).
• Internal or External overload protection for the motors
(depending on the model). Anti-Freeze Thermostat (AFT)
• Electronic control board for unit operation. For evaporator coil freeze -up protection.
• Diagnostic LEDs on the control board for easy
troubleshooting . Western Make Scroll Compressor (WMSC)
• Compressor short cycling protection. Western make scroll compressor.
• Control switch for unit on/off.
Compressor Run Hour Meter (RHM)
• Control circuit breaker.
To monitor operating hours of each compressor.
• Power and control circuit terminal blocks.
• High pressure protection. Circuit Breaker for compressor (CBC)
• Low pressure protection. For those electrical specification which requires additional short
circuit and overload protection for the compressors.

4
External Overload Protection (EOP) Liquid Line Sight Glass (RSG)
R 22
For monitoring refrigerant charge and to provide visual indication
For those electrical specification requires additional overload REFRIGERANT
protection for the compressors.(Not required with CBC option) of moisture presence in the system.

Manual Reset Type High Pressure Switch (MHP)


To replace standard auto reset, capsule type pressure switch. Advanced Micro Processor Control System (AMCS)
An advanced microprocessor based controller can be provided
for the units as option, in case required. This controller
Electric Heating (HTR1) will be with built-in display keypad and has many features.
Electric heating batteries are made up of finned heating elements, For this feature, additional options can be provided and to be
constructed from high quality 80/20 nickel chrome resistance wire specified during time of order:
centred in metal tube by compressed magnesium oxide.
Helical fins are tightly wound around the tubular heating element. ● DTS – Duct Temperature Sensor *
Heater batteries when ordered comes with stage contactors, (In order to control the unit based on return/supply air duct
primary auto reset thermal safety cut-out, secondary manual temperature.) (This is not required with CHTS/CHTS-Wifi
reset thermal safety cut-out and air flow switch.
options)
Control of the heaters will be from the unit controller.
● BMSP – BMS Protocol *
Following are the optional kW ratings for electric heater. Ratings
other than those specified here can be supplied on request. (For interfacing the units with major BMS protocols such as
Consult SKM for details (For models 51055G1 up to 51120G1, BACnet, Modbus or LON. An extra hardware may be required
depending on the protocol)
please consult SKM)

Model Condenser Coil Guard (CGP)


Heater Kw No. of Stages
APMR Wire mesh guard, in painted finish for condensers coils.
Recommended on ground level installation where coil needs to
52130G1 be protected against vandalism.
52150G1
52170G1 18 Stainless Steel Drain Pan (Grade 304) (SDP-304)
Stainless steel drain pan(Grade 304). Insulation under drain pan
52180G1 as per SKM standard.
52210G1
52240G1 Stainless Steel Drain Pan (SDP-316)
Heavy gauge 316 stainless steel drain pan under the entire cooling
52270G1 2 coil.
52300G1 24 Insulation under drain pan as per SKM standard.

52340G1
Circuit breaker for Motors** (CBM)
52380G1 For those electrical specification which requires additional short
circuit and overload protection for the fan motors.
52420G1
48
52500G1 IP 55 Control Panel (ICP)
Table 1

Control Panel for special applications to meet IP55 requirements.


52550G1

Main Isolator (without door interlock) (ISO)


Rotalock Valves on compressors (RVC) For main power isolation. (Consult SKM)
For additional facilitation of maintenance of unit.
BMS Interface Volt Free Contacts (BMVF)
Extra Ball Valve (XFV)
Volt free contacts for run status, common fault status, auto
Extra ball valve can be incorporated in the liquid line. mode status and provision for remote on/off shall be provided
as option if required.
Pressure relief valve (PRV) For additional requirements, please contact SKM.
To protect the unit from being over - pressurized.

Pressure Gauges (SDG1)


Suction and discharge indication of each refrigerant circuit.
Gauges mounted outside the Control Panel.

S.K.M Air Conditioning LLC


5
SKM Packaged Air Conditioners APMRG1 Series

Voltage Monitor Module (VMM) Options for Field Installation


Provides protection in the event of:
• Phase burn-out. Anti-vibration mounts (CAVM)
• Phase reversal. Recommended for roof mounted units or other location in the
• Under / over voltage on the incoming line voltage. vicinity of occupied spaces. where noise may be objectionable.
Up Size Evaporator Motor** (USM)
Low Voltage Thermostat (CHTS)
Unit with one up size evaporator motor. For wall mounting and for cooling /heating operation with 1 or 2
Voltage Monitoring Module as per DEWA (DVM) stages as per model. (Not required with AMCS/CHTS-Wifi
options).
Under voltage relay as per DEWA regulations. This option is
available for Dubai, UAE only.(VMM option is not required if
this option is opted.) Low Voltage Thermostat with Wi-Fi (CHTS-WiFi)
For wall mounting and for cooling /heating operation with 1 or 2
Ball Valve (BLV)
stages as per model and with wireless connectivity or Wi-Fi. (Not
Ball valve can be incorporated in the liquid line. required with AMCS/CHTS options).

Pump Down Facility with solenoid Valve (PDS) ● DTS-TH – Duct Temperature Sensor for 24V Thermostat *
(In order to control the unit based on return/supply air duct
The compressors will switch off each time with a Pumpdown
Cycle in order to prevent Liquid refrigerant migration to the temperature.) (This is not required with AMCS options)
compressor during Off Cycle periods.

Fire Alarm Interlock (VFC-F) Note:


To provide provision for fire alarm interlock.
- *DTS & BMSP options are only available along with AMCS option.
Marine Paint (MP)
- *DTS-TH option is only available along with CHTS/CHTS-Wifi
To provide increased corrosion resistance for coastal environments option.
and offshore location.
- **If CBM combined with USM option please consult SKM as
component might changed.

- Whenever multiple options related to unit control, please consult


SKM for the drawings, as the size of the control panel might change.

6
ENGINEERING SPECIFICATIONS R 22
REFRIGERANT
Model APMR 51055G1 51070G1 51080G1 51090G1 51100G1 51120G1 52130G1

MBh 46.60 59.20 66.40 72.50 82.80 95.70 108.10


Cooling Capacity (1) kW 13.66 17.35 19.46 21.2 24.27 28.05 31.68

EER 8.45 8.33 8.38 8.45 8.39 8.41 8.40


Refrigerant Type - R410A

Type - s

Compressor
Quantity - 1 1 1 1 1 1 2

US Gal 0.52 0.47 0.47 0.66 0.86 0.86 1.19


Oil Charge Ckt (A / B)
Liter 1.95 1.77 1.77 2.51 3.25 3.25 4.50

Type - Hi-Xtubes

Condenser Coil ft 2
18.7 21.3 24 24 24 25.4 37.3
Face Area
2
m 1.7 2.0 2.2 2.2 2.2 2.4 3.5

Condenser Fan
Type - Propeller Direct Drive

Code / Quantity - 630 / 1 630 / 1 710 / 1 710 / 1 710 / 1 710 / 1 710 / 2

Condenser Motor Type - Totally Enclosed Air Over, Class F insulation, 6-pole, IP-54/55 Protected

Type Hi-X tubes

Evaporator Coil ft
2
5.8 5.8 8.9 8.9 8.9 10.7 13.3
Face Area
2
m 0.54 0.54 0.83 0.83 0.83 0.99 1.24

Type Centrifugal double inlet double width belt drive

Code / Quantity 10/10 12/12 12/12 15/15 15/15 15/15 12/12 R2


Evaporator Fan
cfm 1700 2100 2800 3200 3500 4100 4500
Air Flow Rate
l/s 802 991 1321 1510 1651 1934 2123

Type Totally Enclosed Fan Cooled, Class F insulation, 4-pole IP55 Protected
Evaporator Motor
Size kW 0.55 0.55 0.75 1.1 1.1 1.5 1.5

lbs 14.99 16.38 19.80 20.22 20.33 29.63 15.78 / 15.78


Approximate Operating Gas Charge Ckt (A / B)
kg 6.80 7.43 8.98 9.17 9.22 13.44 7.16 / 7.16
Number of Refrigerant Circuits 1 1 1 1 1 1 2

lbs 645 704 897 1046 1056 1176 1622


Unit Operating Weight
kg 293 319 407 474 478 534 736

Table 2

Notes:
(1) Evaporator entering air conditions of 84.2°/66.2°F (29.0°C/19.0°C) dry bulb/wet bulb and condenser entering air temperature
of 114.8°F (46°C ) dry bulb, (Net Capacity).

S.K.M Air Conditioning LLC


7
SKM Packaged Air Conditioners APMRG1 Series

ENGINEERING SPECIFICATIONS

Model APMR 52150G1 52170G1 52180G1 52210G1 52240G1 52270G1 52300G1


MBh 123.30 135.90 145.80 162.70 188.90 212.90 240.60
Cooling Capacity (1) kW 36.14 39.83 42.73 47.7 55.36 62.39 70.51
EER 8.40 8.33 8.20 8.21 8.18 8.26 8.32
Refrigerant Type - R410A
Type - Hermetic Scroll
Quantity - 2 2 2 2 2 2 2
Compressor
US Gal 0.47 0.47 0.66 0.86 0.86 1.90 0.86
Oil Charge Ckt (A / B)
Liter 1.77 1.77 2.51 3.25 3.25 7.20 3.25
Type - Hi-X tubes
Condenser Coil ft2 37.3 52 52 52 52 53.3 53.3
Face Area
2
m 3.5 4.8 4.8 4.8 4.8 5.0 5.0
Type - Propeller Direct Drive
Condenser Fan
Code / Quantity - 710 / 2 710 / 2 710 / 2 710 / 2 710 / 2 710 / 3 710 / 3
Condenser Motor Type - Totally Enclosed Air Over, Class F insulation, 6-pole, IP-54/55 Protected
Type - Hi-X tubes
Evaporator Coil ft2 13.3 15.6 15.6 15.6 21.7 21.7 21.7
Face Area
m2 1.24 1.45 1.45 1.45 2.02 2.02 2.02
Type - Centrifugal double inlet double width belt drive
Code / Quantity - 12/12 R2 12/12 R2 12/12 R2 12/12 R2 12/12 R2 15/15 R2 15/15 R2
Evaporator Fan
cfm 5000 5800 6200 6500 7000 8000 9000
Air Flow Rate
l/s 2359 2737 2926 3067 3303 3775 4247
Type - Totally Enclosed Fan Cooled, Class F insulation, 4-pole IP55 Protected
Evaporator Motor
Size kW 1.5 2.2 2.2 3 3 3 3
lbs 15.78 / 15.78 20.26 / 20.26 20.26 / 20.26 28.79 / 28.79 30.03 / 30.03 31.24 / 31.24 31.24 / 31.24
Approximate Operating Gas Charge Ckt (A / B)
kg 7.16 / 7.16 9.19 / 9.19 9.19 / 9.19 13.06 / 13.06 13.62 / 13.62 14.17 / 14.17 14.17 / 14.17
Number of Refrigerant Circuits - 2 2 2 2 2 2 2
lbs 1622 1956 2032 2090 2288 2724 2739
Unit Operating Weight
kg 736 887 922 948 1038 1235 1242
Table 3

Notes:
(1) Evaporator entering air conditions of 84.2°/66.2°F (29.0°C/19.0°C) dry bulb/wet bulb and condenser entering air temperature
of 114.8°F (46°C ) dry bulb, (Net Capacity).

8
ENGINEERING SPECIFICATIONS R 22
REFRIGERANT
Model APMR 52340G1 52380G1 52420G1 52500G1 52550G1
MBh 274.60 319.30 357.80 404.80 449.00
Cooling Capacity (1) kW 80.48 93.58 104.86 118.6 131.59
EER 8.10 8.15 7.99 8.01 7.90
Refrigerant Type - R410A
Type - Hermetic Scroll
Quantity - 2 2 2 2 2
Compressor
US Gal 0.86 1.19 / 0.86 1.19 1.19 / 1.19 1.19
Oil Charge Ckt (A / B)
Liter 3.25 4.5 / 3.25 4.50 4.5 / 4.5 4.50
Type - Hi-X tubes
Condenser Coil ft2 60 65 69.3 78 130
Face Area 2
m 5.6 6.0 6.4 7.2 12.1
Type - Propeller Direct Drive
Condenser Fan
Code / Quantity - 710 / 3 710 / 4 800 / 3 800 / 3 800 / 4
Condenser Motor Type - Totally Enclosed Air Over, Class F insulation, 6-pole, IP-54/55 Protected
Type - Hi-X tubes
Evaporator Coil 2
ft 26 30.3 30.3 37.5 37.5
Face Area 2
m 2.42 2.81 2.81 3.48 3.48
Type - Centrifugal double inlet double width belt drive
Code / Quantity - 15/15 R2 18/18 R2 18/18 R2 18/18 R2 18/18 R2
Evaporator Fan
cfm 10000 10800 11800 13500 15800
Air Flow Rate
l/s 4719 5097 5568 6371 7456
Type - Totally Enclosed Fan Cooled, Class F insulation, 4-pole IP55 Protected
Evaporator Motor
Size kW 4 4 5.5 5.5 7.5
lbs 34.88 / 34.88 42.11 / 42.11 52.91 / 52.91 60.43 / 60.43 66.14 / 66.14
Refrigerant Operating Charge Ckt (A / B)
kg 15.82 / 15.82 19.1 / 19.1 24 / 24 27.41 / 27.41 30 / 30
Number of Refrigerant Circuits - 2 2 2 2 2
lbs 2776 3391 3603 3835 4857
Unit Operating Weight
kg 1259 1538 1634 1739 2203

Table 4

Notes:
(1) Evaporator entering air conditions of 84.2°/66.2°F (29.0°C/19.0°C) dry bulb/wet bulb and condenser entering air temperature
of 114.8°F (46°C ) dry bulb, (Net Capacity).

S.K.M Air Conditioning LLC


9
SKM Packaged Air Conditioners APMRG1 Series

GROSS CAPACITY RATINGS


AFR Condenser Entering Air Temperature
cfm 95°F (35°C) 105°F (40.6°C) 114.8°F (46°C) 118.4°F (48°C) 125.6°F (52°C)
Model EWB
APMR l/s Total Capacity Sensible Capacity PI Total Capacity Sensible Capacity PI Total Capacity Sensible Capacity PI Total Capacity Sensible Capacity PI Total Capacity Sensible Capacity PI

(BPF) °F MBh kW MBh kW kW MBh kW MBh kW kW MBh kW MBh kW kW MBh kW MBh kW kW MBh kW MBh kW kW
1600 62 49.4 14.5 49.4 14.5 3.4 46.7 13.7 46.7 13.7 3.9 43.8 12.8 43.8 12.8 4.5 44.6 13.1 44.6 13.1 4.7 42.3 12.4 42.3 12.4 5.1
755 66.2 53.5 15.7 47.4 13.9 3.4 50.5 14.8 46.3 13.6 3.9 47.2 13.8 45.1 13.2 4.5 46.0 13.5 44.6 13.1 4.7 43.6 12.8 43.6 12.8 5.1
0.09 72 59.9 17.6 37.8 11.1 3.5 56.5 16.5 36.6 10.7 4.0 52.2 15.3 35.2 10.3 4.6 50.6 14.8 34.7 10.2 4.9 47.6 13.9 33.7 9.9 5.3
1700 62 50.0 14.7 50.0 14.7 3.4 47.2 13.8 47.2 13.8 3.9 46.2 13.5 46.2 13.5 4.5 45.0 13.2 45.0 13.2 4.7 42.6 12.5 42.6 12.5 5.1
51055G1 802 66.2 54.0 15.8 49.1 14.4 3.4 50.9 14.9 48.0 14.1 3.9 47.6 14.0 46.7 13.7 4.5 46.4 13.6 46.3 13.6 4.7 44.0 12.9 44.0 12.9 5.1
0.09 72 60.5 17.7 39.0 11.4 3.5 56.8 16.6 37.7 11.1 4.0 52.4 15.4 36.3 10.6 4.6 50.9 14.9 35.8 10.5 4.9 47.8 14.0 34.8 10.2 5.3
2600 62 55.4 16.2 55.4 16.2 3.4 52.1 15.3 52.1 15.3 4.0 48.6 14.2 48.6 14.2 4.5 47.3 13.9 47.3 13.9 4.8 44.6 13.1 44.6 13.1 5.2
1227 66.2 57.1 16.7 57.1 16.7 3.4 53.8 15.8 53.8 15.8 4.0 50.3 14.7 50.3 14.7 4.6 48.9 14.3 48.9 14.3 4.8 46.2 13.5 46.2 13.5 5.2
0.13 72 62.8 18.4 48.5 14.2 3.5 58.6 17.2 47.2 13.8 4.1 - - - - - - - - - - - - - - -
1600 62 61.1 17.9 59.5 17.4 4.8 57.6 16.9 57.6 16.9 5.5 54.1 15.8 54.1 15.8 6.2 52.8 15.5 52.8 15.5 6.4 50.2 14.7 50.2 14.7 6.9
755 66.2 67.6 19.8 53.1 15.6 4.9 63.4 18.6 51.4 15.1 5.6 59.0 17.3 49.6 14.5 6.3 57.4 16.8 49.0 14.4 6.5 54.4 15.9 47.8 14.0 7.0
0.09 72 73.7 21.6 42.7 12.5 5.0 69.7 20.4 41.2 12.1 5.7 65.6 19.2 39.8 11.7 6.4 64.0 18.8 39.2 11.5 6.6 61.0 17.9 38.2 11.2 7.1
2100 62 64.0 18.8 64.0 18.8 4.8 60.4 17.7 60.4 17.7 5.5 56.7 16.6 56.7 16.6 6.2 55.3 16.2 55.3 16.2 6.5 52.5 15.4 52.5 15.4 7.0
51070G1 991 66.2 69.7 20.4 61.0 17.9 4.9 65.4 19.2 59.4 17.4 5.6 61.2 17.9 57.8 16.9 6.3 59.6 17.5 57.2 16.8 6.6 56.6 16.6 56.0 16.4 7.0
0.11 72 77.4 22.7 48.5 14.2 5.1 73.0 21.4 47.0 13.8 5.8 68.5 20.1 45.5 13.3 6.4 66.8 19.6 44.9 13.2 6.7 63.0 18.5 43.7 12.8 7.1
2600 62 66.2 19.4 66.2 19.4 4.9 62.5 18.3 62.5 18.3 5.6 61.0 17.9 61.0 17.9 6.3 59.4 17.4 59.4 17.4 6.6 56.4 16.5 56.4 16.5 7.0
1227 66.2 71.5 20.9 68.7 20.1 5.0 67.2 19.7 67.1 19.7 5.6 62.8 18.4 62.8 18.4 6.3 61.3 18.0 61.3 18.0 6.6 58.1 17.0 58.1 17.0 7.0
0.13 72 79.9 23.4 53.9 15.8 5.1 75.1 22.0 52.4 15.3 5.8 69.7 20.4 50.6 14.8 6.5 67.8 19.9 50.0 14.7 6.7 64.0 18.8 48.8 14.3 7.1
2500 62 74.8 21.9 74.8 21.9 5.1 70.8 20.8 70.8 20.8 5.8 69.6 20.4 69.6 20.4 6.7 68.0 19.9 68.0 19.9 7.0 64.7 19.0 64.7 19.0 7.5
1180 66.2 80.7 23.7 72.9 21.4 5.2 76.4 22.4 71.3 20.9 5.9 71.8 21.1 69.6 20.4 6.7 70.2 20.6 68.9 20.2 7.0 66.9 19.6 66.9 19.6 7.6
0.09 72 90.3 26.5 57.9 17.0 5.4 85.4 25.0 56.3 16.5 6.1 80.0 23.5 54.5 16.0 6.9 78.1 22.9 53.8 15.8 7.2 74.4 21.8 52.6 15.4 7.7
2800 62 76.2 22.3 76.2 22.3 5.1 75.3 22.1 75.3 22.1 5.9 70.8 20.7 70.8 20.7 6.7 69.1 20.3 69.1 20.3 7.0 65.7 19.3 65.7 19.3 7.5
51080G1 1321 66.2 82.1 24.1 78.0 22.8 5.2 77.6 22.7 76.3 22.4 5.9 73.0 21.4 73.0 21.4 6.7 71.3 20.9 71.3 20.9 7.0 68.0 19.9 68.0 19.9 7.6
0.1 72 91.5 26.8 61.2 17.9 5.4 86.2 25.3 59.5 17.4 6.1 80.9 23.7 57.8 16.9 6.9 79.0 23.2 57.2 16.8 7.2 75.3 22.1 56.0 16.4 7.7
4000 62 83.3 24.4 83.3 24.4 5.2 78.6 23.0 78.6 23.0 6.0 73.7 21.6 73.7 21.6 6.8 71.9 21.1 71.9 21.1 7.0 68.4 20.0 68.4 20.0 7.6
1888 66.2 85.9 25.2 85.9 25.2 5.3 81.2 23.8 81.2 23.8 6.0 76.5 22.4 76.5 22.4 6.8 74.7 21.9 74.7 21.9 7.1 71.2 20.9 71.2 20.9 7.6
0.13 72 94.1 27.6 73.7 21.6 5.5 88.9 26.1 72.1 21.1 6.2 83.8 24.6 70.5 20.7 7.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
2500 62 79.5 23.3 79.5 23.3 5.5 75.2 22.0 75.2 22.0 6.3 70.5 20.7 70.5 20.7 7.3 68.7 20.1 68.7 20.1 7.6 68.1 20.0 68.1 20.0 8.2
1180 66.2 85.9 25.2 74.9 22.0 5.7 81.0 23.7 73.0 21.4 6.5 75.8 22.2 71.1 20.8 7.4 74.0 21.7 70.4 20.6 7.7 70.3 20.6 69.0 20.2 8.2
0.09 72 95.7 28.1 59.8 17.5 6.0 90.4 26.5 57.9 17.0 6.7 84.9 24.9 56.1 16.4 7.4 82.6 24.2 55.3 16.2 7.7 78.3 22.9 53.9 15.8 8.2
3200 62 82.8 24.3 82.8 24.3 5.6 81.3 23.8 81.3 23.8 6.5 76.1 22.3 76.1 22.3 7.4 74.2 21.7 74.2 21.7 7.7 70.3 20.6 70.3 20.6 8.2
51090G1 1510 66.2 88.9 26.1 86.4 25.3 5.8 83.7 24.5 83.7 24.5 6.6 78.5 23.0 78.5 23.0 7.4 76.5 22.4 76.5 22.4 7.7 72.8 21.3 72.8 21.3 8.2
0.11 72 98.8 28.9 67.5 19.8 6.1 92.6 27.1 65.5 19.2 6.8 86.6 25.4 63.6 18.6 7.4 84.5 24.8 62.9 18.4 7.6 80.2 23.5 61.6 18.0 8.1
4000 62 88.7 26.0 88.7 26.0 5.8 83.4 24.5 83.4 24.5 6.6 78.0 22.9 78.0 22.9 7.4 76.0 22.3 76.0 22.3 7.7 72.0 21.1 72.0 21.1 8.2
1888 66.2 91.3 26.8 91.3 26.8 5.8 86.0 25.2 86.0 25.2 6.6 80.7 23.6 80.7 23.6 7.4 78.7 23.1 78.7 23.1 7.7 74.8 21.9 74.8 21.9 8.2
0.13 72 100.3 29.4 75.7 22.2 6.1 94.3 27.6 73.8 21.6 6.8 88.4 25.9 72.0 21.1 7.4 86.3 25.3 71.3 20.9 7.6 0.0 0.0 0.0 0.0 0.0
2500 62 87.7 25.7 87.7 25.7 6.5 82.8 24.3 82.8 24.3 7.4 77.7 22.8 77.7 22.8 8.3 75.9 22.2 75.9 22.2 8.7 72.3 21.2 72.3 21.2 9.3
1180 66.2 95.9 28.1 78.9 23.1 6.6 89.9 26.4 76.5 22.4 7.5 84.1 24.7 74.2 21.8 8.5 82.1 24.1 73.4 21.5 8.8 78.1 22.9 71.9 21.1 9.4
0.09 72 105.5 30.9 63.2 18.5 6.8 99.9 29.3 61.2 17.9 7.8 94.3 27.6 59.3 17.4 8.8 92.2 27.0 58.6 17.2 9.1 88.1 25.8 57.2 16.8 9.7
3500 62 92.7 27.2 92.7 27.2 6.6 87.5 25.6 87.5 25.6 7.5 85.5 25.1 85.5 25.1 8.5 83.5 24.5 83.5 24.5 8.8 79.4 23.3 79.4 23.3 9.5
51100G1 1652 66.2 99.8 29.2 94.8 27.8 6.7 94.0 27.6 92.7 27.2 7.6 88.2 25.8 88.2 25.8 8.6 86.0 25.2 86.0 25.2 8.9 82.0 24.0 82.0 24.0 9.5
0.11 72 111.0 32.5 74.4 21.8 6.9 104.6 30.7 72.3 21.2 7.9 98.0 28.7 70.2 20.6 8.9 95.6 28.0 69.4 20.3 9.2 90.9 26.6 67.9 19.9 9.8
4000 62 94.5 27.7 94.5 27.7 6.6 92.8 27.2 92.8 27.2 7.6 86.9 25.5 86.9 25.5 8.5 84.8 24.8 84.8 24.8 8.9 80.6 23.6 80.6 23.6 9.5
1888 66.2 101.4 29.7 101.4 29.7 6.7 95.5 28.0 95.5 28.0 7.7 89.6 26.3 89.6 26.3 8.6 87.5 25.6 87.5 25.6 9.0 83.4 24.4 83.4 24.4 9.6
0.13 72 112.4 32.9 79.5 23.3 6.9 105.6 30.9 77.3 22.7 7.9 99.1 29.0 75.3 22.1 8.9 96.7 28.3 74.5 21.8 9.3 0.0 0.0 0.0 0.0 0.0
3000 62 104.3 30.6 104.3 30.6 7.4 98.3 28.8 98.3 28.8 8.5 92.1 27.0 92.1 27.0 9.7 89.8 26.3 89.8 26.3 10.1 85.2 25.0 85.2 25.0 10.9
1416 66.2 114.1 33.5 94.3 27.6 7.5 106.8 31.3 91.4 26.8 8.6 99.6 29.2 88.6 26.0 9.8 97.1 28.5 87.6 25.7 10.2 92.2 27.0 85.7 25.1 11.0
0.09 72 125.9 36.9 75.6 22.1 7.8 119.0 34.9 73.1 21.4 8.9 111.8 32.8 70.7 20.7 10.0 109.3 32.0 69.8 20.5 10.4 104.4 30.6 68.1 20.0 11.1
4100 62 110.0 32.2 110.0 32.2 7.4 103.6 30.4 103.6 30.4 8.6 101.0 29.6 101.0 29.6 9.8 98.4 28.9 98.4 28.9 10.3 93.4 27.4 93.4 27.4 11.0
51120G1 1935 66.2 118.6 34.7 111.9 32.8 7.6 111.5 32.7 109.3 32.0 8.7 104.1 30.5 104.1 30.5 9.9 101.5 29.8 101.5 29.8 10.3 96.5 28.3 96.5 28.3 11.1
0.11 72 132.2 38.7 88.0 25.8 8.0 124.3 36.4 85.4 25.0 9.1 115.9 34.0 82.7 24.2 10.1 112.9 33.1 81.7 24.0 10.4 107.5 31.5 80.0 23.4 11.2
4800 62 112.5 33.0 112.5 33.0 7.5 110.3 32.3 110.3 32.3 8.7 103.0 30.2 103.0 30.2 9.9 100.3 29.4 100.3 29.4 10.3 95.1 27.9 95.1 27.9 11.0
2265 66.2 120.9 35.4 120.9 35.4 7.7 113.6 33.3 113.6 33.3 8.8 106.2 31.1 106.2 31.1 9.9 103.6 30.4 103.6 30.4 10.3 98.6 28.9 98.6 28.9 11.1
0.13 72 134.2 39.3 95.2 27.9 8.1 125.7 36.8 92.5 27.1 9.1 117.4 34.4 89.9 26.3 10.1 114.5 33.6 89.0 26.1 10.5 109.2 32.0 87.3 25.6 11.2
3700 62 116.0 34.0 116.0 34.0 8.1 109.7 32.1 109.7 32.1 9.3 102.7 30.1 102.7 30.1 10.5 104.5 30.6 104.5 30.6 11.0 99.0 29.0 99.0 29.0 11.9
1746 66.2 125.4 36.8 110.3 32.3 8.2 118.2 34.6 107.5 31.5 9.4 110.6 32.4 104.6 30.7 10.6 107.7 31.6 103.6 30.4 11.1 102.2 29.9 101.5 29.7 12.1
0.09 72 139.5 40.9 87.8 25.7 8.3 131.6 38.6 85.0 24.9 9.6 122.6 35.9 82.0 24.0 11.1 119.2 34.9 80.9 23.7 11.7 112.6 33.0 78.8 23.1 12.8
4500 62 119.9 35.1 119.9 35.1 8.2 117.8 34.5 117.8 34.5 9.4 110.2 32.3 110.2 32.3 10.6 107.3 31.5 107.3 31.5 11.1 101.6 29.8 101.6 29.8 12.0
52130G1 2124 66.2 128.8 37.8 123.5 36.2 8.3 121.3 35.6 120.7 35.4 9.4 113.6 33.3 113.6 33.3 10.7 110.7 32.4 110.7 32.4 11.2 105.0 30.8 105.0 30.8 12.2
0.1 72 142.8 41.8 96.6 28.3 8.3 133.6 39.2 93.6 27.4 9.6 124.5 36.5 90.7 26.6 11.2 121.1 35.5 89.6 26.3 11.8 114.6 33.6 87.5 25.7 13.0
5900 62 129.4 37.9 129.4 37.9 8.3 121.6 35.6 121.6 35.6 9.4 113.5 33.3 113.5 33.3 10.7 110.5 32.4 110.5 32.4 11.2 104.5 30.6 104.5 30.6 12.2
2784 66.2 133.1 39.0 133.1 39.0 8.3 125.4 36.8 125.4 36.8 9.5 117.3 34.4 117.3 34.4 10.8 114.4 33.5 114.4 33.5 11.4 108.4 31.8 108.4 31.8 12.4
0.12 72 145.5 42.6 111.0 32.5 8.3 136.4 40.0 108.2 31.7 9.7 127.3 37.3 105.4 30.9 11.4 124.0 36.3 104.3 30.6 12.1 0.0 0.0 0.0 0.0 0.0

Table 5

See Notes on page 12

10
GROSS CAPACITY RATINGS R 22
REFRIGERANT
AFR Condenser Entering Air Temperature
cfm 95°F (35°C) 105°F (40.6°C) 114.8°F (46°C) 118.4°F (48°C) 125.6°F (52°C)
Model EWB
APMR l/s Total Capacity Sensible Capacity PI Total Capacity Sensible Capacity PI Total Capacity Sensible Capacity PI Total Capacity Sensible Capacity PI Total Capacity Sensible Capacity PI

(BPF) °F MBh kW MBh kW kW MBh kW MBh kW kW MBh kW MBh kW kW MBh kW MBh kW kW MBh kW MBh kW kW
3700 62 128.7 37.7 128.7 37.7 9.4 121.7 35.7 121.7 35.7 10.6 114.4 33.5 114.4 33.5 12.0 111.6 32.7 111.6 32.7 12.6 106.2 31.1 106.2 31.1 13.6
1746 66.2 141.0 41.3 116.5 34.1 9.5 132.4 38.8 113.1 33.1 10.8 123.8 36.3 109.7 32.2 12.2 120.7 35.4 108.5 31.8 12.7 114.6 33.6 106.2 31.1 13.7
0.09 72 156.1 45.7 93.5 27.4 9.8 147.6 43.3 90.6 26.5 11.1 138.7 40.7 87.5 25.6 12.5 135.4 39.7 86.3 25.3 13.0 128.6 37.7 84.0 24.6 13.9
5000 62 135.6 39.7 135.6 39.7 9.5 128.3 37.6 128.3 37.6 10.7 125.3 36.7 125.3 36.7 12.2 122.2 35.8 122.2 35.8 12.7 115.8 33.9 115.8 33.9 13.7
52150G1 2360 66.2 146.4 42.9 137.5 40.3 9.6 138.1 40.5 134.3 39.4 10.9 129.2 37.9 129.2 37.9 12.3 125.9 36.9 125.9 36.9 12.8 119.5 35.0 119.5 35.0 13.8
0.11 72 164.0 48.1 108.4 31.8 9.9 154.3 45.2 105.2 30.8 11.2 143.4 42.0 101.7 29.8 12.5 139.4 40.9 100.4 29.4 13.0 131.7 38.6 97.9 28.7 13.9
5900 62 139.0 40.7 139.0 40.7 9.5 136.8 40.1 136.8 40.1 10.9 127.9 37.5 127.9 37.5 12.3 124.6 36.5 124.6 36.5 12.8 118.0 34.6 118.0 34.6 13.7
2784 66.2 149.6 43.9 149.6 43.9 9.7 140.9 41.3 140.9 41.3 11.0 131.9 38.7 131.9 38.7 12.4 128.6 37.7 128.6 37.7 12.9 122.0 35.8 122.0 35.8 13.8
0.12 72 166.9 48.9 117.8 34.5 10.0 156.0 45.7 114.3 33.5 11.2 145.2 42.6 110.9 32.5 12.6 141.3 41.4 109.7 32.2 13.1 133.7 39.2 107.3 31.5 13.9
4300 62 144.2 42.3 144.2 42.3 10.0 136.7 40.1 136.7 40.1 11.5 129.0 37.8 129.0 37.8 13.1 126.2 37.0 126.2 37.0 13.7 120.2 35.2 120.2 35.2 14.8
2029 66.2 157.1 46.1 132.7 38.9 10.2 148.3 43.5 129.2 37.9 11.7 139.5 40.9 125.8 36.9 13.3 136.3 40.0 124.6 36.5 13.9 129.9 38.1 122.2 35.8 15.0
0.09 72 174.8 51.2 106.4 31.2 10.5 166.1 48.7 103.4 30.3 12.0 156.9 46.0 100.2 29.4 13.6 153.5 45.0 99.1 29.0 14.2 146.4 42.9 96.7 28.3 15.2
5800 62 151.9 44.5 151.9 44.5 10.2 143.8 42.2 143.8 42.2 11.6 141.2 41.4 141.2 41.4 13.3 137.9 40.4 137.9 40.4 13.9 131.2 38.4 131.2 38.4 15.0
52170G1 2737 66.2 163.7 48.0 157.2 46.1 10.3 154.8 45.4 153.8 45.1 11.8 145.6 42.7 145.6 42.7 13.4 142.3 41.7 142.3 41.7 14.0 135.7 39.8 135.7 39.8 15.1
0.11 72 183.0 53.7 123.4 36.2 10.7 172.4 50.5 120.0 35.2 12.1 161.7 47.4 116.5 34.1 13.7 157.9 46.3 115.3 33.8 14.2 150.5 44.1 112.9 33.1 15.3
7000 62 162.6 47.7 162.6 47.7 10.3 153.7 45.1 153.7 45.1 11.7 144.4 42.3 144.4 42.3 13.4 140.9 41.3 140.9 41.3 13.9 134.0 39.3 134.0 39.3 15.0
3304 66.2 167.5 49.1 167.5 49.1 10.4 158.5 46.4 158.5 46.4 11.8 149.2 43.7 149.2 43.7 13.4 145.8 42.7 145.8 42.7 14.0 139.0 40.7 139.0 40.7 15.1
0.13 72 185.5 54.4 135.6 39.7 10.8 174.9 51.3 132.2 38.8 12.2 164.5 48.2 129.0 37.8 13.7 160.7 47.1 127.8 37.5 14.3 153.4 45.0 125.5 36.8 15.3
4300 62 153.5 45.0 153.5 45.0 10.8 145.1 42.5 145.1 42.5 12.4 136.2 39.9 136.2 39.9 14.4 132.9 39.0 132.9 39.0 15.1 126.4 37.1 126.4 37.1 16.4
2029 66.2 168.3 49.3 137.2 40.2 11.2 157.9 46.3 133.0 39.0 12.8 147.5 43.2 128.9 37.8 14.6 143.7 42.1 127.4 37.4 15.2 136.6 40.0 124.7 36.5 16.4
0.09 72 185.0 54.2 110.0 32.2 11.6 175.2 51.3 106.5 31.2 13.2 165.1 48.4 103.0 30.2 14.7 161.3 47.3 101.7 29.8 15.3 153.9 45.1 99.2 29.1 16.3
6200 62 163.1 47.8 163.1 47.8 11.0 154.1 45.2 154.1 45.2 12.7 150.6 44.1 150.6 44.1 14.6 146.8 43.0 146.8 43.0 15.2 139.3 40.8 139.3 40.8 16.4
52180G1 2926 66.2 175.7 51.5 167.4 49.1 11.4 165.6 48.5 163.6 48.0 13.0 155.2 45.5 155.2 45.5 14.7 151.3 44.4 151.3 44.4 15.3 143.9 42.2 143.9 42.2 16.4
0.12 72 195.9 57.4 131.4 38.5 12.0 184.5 54.1 127.7 37.4 13.4 172.3 50.5 123.8 36.3 14.7 167.9 49.2 122.4 35.9 15.2 159.3 46.7 119.6 35.1 16.2
7000 62 165.9 48.6 165.9 48.6 11.1 163.1 47.8 163.1 47.8 12.9 152.8 44.8 152.8 44.8 14.6 148.9 43.6 148.9 43.6 15.3 141.2 41.4 141.2 41.4 16.4
3304 66.2 178.3 52.3 178.3 52.3 11.4 168.0 49.2 168.0 49.2 13.0 157.5 46.2 157.5 46.2 14.7 153.6 45.0 153.6 45.0 15.3 146.1 42.8 146.1 42.8 16.3
0.13 72 198.4 58.1 139.7 40.9 12.1 185.9 54.5 135.7 39.8 13.5 173.9 51.0 131.9 38.7 14.7 169.6 49.7 130.6 38.3 15.2 161.2 47.2 127.9 37.5 16.1
4300 62 172.1 50.4 163.5 47.9 12.3 162.6 47.7 159.2 46.7 14.0 152.6 44.7 152.6 44.7 16.0 149.0 43.7 149.0 43.7 16.7 141.8 41.5 141.8 41.5 18.0
2029 66.2 189.1 55.4 145.8 42.7 12.6 179.9 52.7 142.0 41.6 14.3 167.9 49.2 137.1 40.2 16.2 163.3 47.9 135.2 39.6 16.9 154.8 45.4 131.8 38.6 18.2
0.09 72 206.5 60.5 117.7 34.5 12.8 196.2 57.5 114.0 33.4 14.6 185.3 54.3 110.1 32.3 16.5 181.4 53.2 108.7 31.9 17.3 173.6 50.9 106.0 31.1 18.6
6500 62 183.8 53.9 183.8 53.9 12.5 174.2 51.1 174.2 51.1 14.2 163.8 48.0 163.8 48.0 16.1 160.0 46.9 160.0 46.9 16.8 152.1 44.6 152.1 44.6 18.2
52210G1 3068 66.2 199.6 58.5 180.7 53.0 12.7 188.3 55.2 176.4 51.7 14.4 176.7 51.8 172.1 50.4 16.4 172.5 50.6 170.5 50.0 17.1 164.2 48.1 164.2 48.1 18.4
0.12 72 221.7 65.0 142.7 41.8 13.0 210.2 61.6 138.9 40.7 14.8 198.4 58.1 135.0 39.6 16.9 194.1 56.9 133.6 39.2 17.6 184.3 54.0 130.5 38.2 19.0
7000 62 185.9 54.5 185.9 54.5 12.5 176.1 51.6 176.1 51.6 14.3 165.5 48.5 165.5 48.5 16.2 161.5 47.3 161.5 47.3 16.9 160.5 47.1 160.5 47.1 18.3
3304 66.2 201.3 59.0 188.3 55.2 12.7 190.0 55.7 184.0 53.9 14.5 178.4 52.3 178.4 52.3 16.4 174.1 51.0 174.1 51.0 17.1 165.7 48.6 165.7 48.6 18.4
0.13 72 224.1 65.7 148.1 43.4 13.0 212.2 62.2 144.2 42.3 14.9 200.0 58.6 140.2 41.1 16.9 195.1 57.2 138.6 40.6 17.6 185.3 54.3 135.5 39.7 19.0
6000 62 209.1 61.3 209.1 61.3 14.7 197.1 57.8 197.1 57.8 16.9 184.6 54.1 184.6 54.1 19.4 180.0 52.8 180.0 52.8 20.2 170.8 50.1 170.8 50.1 21.9
2832 66.2 228.7 67.0 189.0 55.4 15.0 214.2 62.8 183.1 53.7 17.2 199.7 58.5 177.5 52.0 19.6 194.6 57.1 175.5 51.4 20.4 184.9 54.2 171.8 50.4 22.0
0.09 72 252.5 74.0 151.5 44.4 15.6 238.5 69.9 146.6 43.0 17.8 224.3 65.7 141.6 41.5 20.0 219.1 64.2 139.9 41.0 20.8 209.3 61.3 136.6 40.0 22.2
7000 62 214.8 63.0 214.8 63.0 14.8 202.5 59.4 202.5 59.4 17.0 189.5 55.5 189.5 55.5 19.4 184.8 54.2 184.8 54.2 20.3 183.2 53.7 183.2 53.7 22.0
52240G1 3304 66.2 232.8 68.2 205.1 60.1 15.1 218.7 64.1 199.6 58.5 17.3 204.4 59.9 194.3 56.9 19.7 199.2 58.4 192.3 56.4 20.5 189.2 55.5 188.5 55.3 22.0
0.1 72 259.1 75.9 163.1 47.8 15.8 244.5 71.7 158.1 46.3 18.0 229.5 67.3 153.1 44.9 20.1 223.4 65.5 151.1 44.3 20.8 212.2 62.2 147.4 43.2 22.2
9700 62 226.0 66.2 226.0 66.2 14.9 221.6 64.9 221.6 64.9 17.4 206.7 60.6 206.7 60.6 19.7 201.3 59.0 201.3 59.0 20.5 190.9 56.0 190.9 56.0 22.1
4578 66.2 242.7 71.1 242.7 71.1 15.3 228.2 66.9 228.2 66.9 17.5 213.3 62.5 213.3 62.5 19.8 208.0 61.0 208.0 61.0 20.6 197.9 58.0 197.9 58.0 22.1
0.13 72 269.0 78.9 191.8 56.2 16.1 252.0 73.9 186.3 54.6 18.2 235.6 69.0 181.2 53.1 20.2 229.8 67.4 179.4 52.6 20.9 219.2 64.2 176.0 51.6 22.3
6000 62 230.7 67.6 223.8 65.6 16.2 217.0 63.6 217.0 63.6 18.6 202.8 59.4 202.8 59.4 21.4 197.5 57.9 197.5 57.9 22.4 187.1 54.8 187.1 54.8 24.4
2832 66.2 254.6 74.6 199.6 58.5 16.6 238.9 70.0 193.1 56.6 19.1 221.3 64.9 186.0 54.5 21.8 215.0 63.0 183.5 53.8 22.8 203.0 59.5 178.8 52.4 24.6
0.09 72 277.5 81.3 160.4 47.0 16.9 262.0 76.8 154.8 45.4 19.5 245.9 72.1 149.2 43.7 22.3 240.1 70.4 147.1 43.1 23.4 228.4 67.0 143.1 41.9 25.3
8000 62 242.0 70.9 242.0 70.9 16.4 228.0 66.8 228.0 66.8 18.9 213.2 62.5 213.2 62.5 21.6 207.7 60.9 207.7 60.9 22.6 196.5 57.6 196.5 57.6 24.5
52270G1 3776 66.2 263.2 77.1 231.1 67.7 16.7 246.6 72.3 224.8 65.9 19.2 229.9 67.4 218.5 64.1 21.9 223.8 65.6 216.2 63.4 23.0 211.8 62.1 211.7 62.0 24.8
0.11 72 291.6 85.5 183.4 53.8 17.1 274.9 80.6 177.8 52.1 19.7 257.6 75.5 172.0 50.4 22.6 251.2 73.6 169.9 49.8 23.7 237.0 69.5 165.3 48.5 25.5
9700 62 249.4 73.1 249.4 73.1 16.5 234.9 68.9 234.9 68.9 19.0 219.3 64.3 219.3 64.3 21.7 222.5 65.2 222.5 65.2 22.9 210.3 61.7 210.3 61.7 24.8
4578 66.2 269.1 78.9 257.3 75.4 16.8 252.7 74.1 251.2 73.6 19.3 235.6 69.1 235.6 69.1 22.1 229.3 67.2 229.3 67.2 23.1 217.2 63.7 217.2 63.7 25.0
0.13 72 299.5 87.8 201.6 59.1 17.2 281.9 82.6 195.9 57.4 19.8 261.9 76.7 189.5 55.5 22.7 254.6 74.6 187.2 54.9 23.8 240.8 70.6 182.8 53.6 25.7
6000 62 249.4 73.1 232.3 68.1 18.5 233.7 68.5 225.1 66.0 21.2 217.7 63.8 217.7 63.8 24.0 211.9 62.1 211.9 62.1 25.0 200.6 58.8 200.6 58.8 26.9
2832 66.2 272.3 79.8 206.9 60.7 19.0 257.4 75.5 200.7 58.8 21.7 239.9 70.3 193.5 56.7 24.4 232.7 68.2 190.6 55.9 25.4 219.0 64.2 185.1 54.2 27.2
0.09 72 297.3 87.1 167.7 49.2 19.5 280.8 82.3 161.6 47.4 22.1 263.2 77.2 155.3 45.5 24.8 256.8 75.3 153.0 44.8 25.8 244.2 71.6 148.6 43.5 27.6
9000 62 265.2 77.7 265.2 77.7 18.9 249.5 73.1 249.5 73.1 21.5 233.1 68.3 233.1 68.3 24.3 227.0 66.5 227.0 66.5 25.3 214.8 63.0 214.8 63.0 27.1
52300G1 4248 66.2 289.1 84.7 255.1 74.8 19.4 270.2 79.2 248.0 72.7 21.9 251.4 73.7 240.9 70.6 24.6 244.7 71.7 238.4 69.9 25.6 231.4 67.8 231.4 67.8 27.4
0.12 72 319.7 93.7 202.0 59.2 19.7 300.8 88.2 195.7 57.3 22.4 280.9 82.3 189.1 55.4 25.2 273.5 80.2 186.7 54.7 26.1 258.2 75.7 181.7 53.3 27.8
9700 62 268.2 78.6 268.2 78.6 19.0 252.3 74.0 252.3 74.0 21.6 235.7 69.1 235.7 69.1 24.3 229.3 67.2 229.3 67.2 25.3 226.5 66.4 226.5 66.4 27.3
4578 66.2 291.2 85.4 265.7 77.9 19.4 272.6 79.9 258.6 75.8 22.0 253.9 74.4 251.6 73.7 24.7 246.9 72.4 246.9 72.4 25.6 233.6 68.5 233.6 68.5 27.4
0.13 72 323.3 94.8 209.5 61.4 19.7 303.9 89.1 203.1 59.5 22.4 283.5 83.1 196.4 57.6 25.2 275.4 80.7 193.8 56.8 26.2 259.5 76.1 188.7 55.3 27.8

Table 6

See Notes on page 12

S.K.M Air Conditioning LLC


11
SKM Packaged Air Conditioners APMRG1 Series

GROSS CAPACITY RATINGS


AFR Condenser Entering Air Temperature
Model cfm 95°F (35°C) 105°F (40.6°C) 114.8°F (46°C) 118.4°F (48°C) 125.6°F (52°C)
EWB

APMR l/s Total Capacity Sensible Capacity PI Total Capacity Sensible Capacity PI Total Capacity Sensible Capacity PI Total Capacity Sensible Capacity PI Total Capacity Sensible Capacity PI

(BPF) °F MBh kW MBh kW kW MBh kW MBh kW kW MBh kW MBh kW kW MBh kW MBh kW kW MBh kW MBh kW kW
7200 62 292.0 85.6 275.4 80.7 22.8 274.8 80.5 267.6 78.4 25.7 257.7 75.5 257.7 75.5 28.8 251.5 73.7 251.5 73.7 29.8 239.5 70.2 239.5 70.2 31.9
3398 66.2 319.4 93.6 245.3 71.9 23.5 302.9 88.8 238.4 69.9 26.5 282.8 82.9 230.2 67.5 29.4 275.2 80.7 227.1 66.6 30.4 260.8 76.4 221.3 64.9 32.4
0.09 72 348.0 102.0 198.0 58.0 24.1 329.5 96.6 191.2 56.0 27.0 310.5 91.0 184.4 54.1 30.0 303.6 89.0 182.0 53.3 31.0 0.0 0.0 0.0 0.0 0.0
10000 62 307.1 90.0 307.1 90.0 23.2 289.9 85.0 289.9 85.0 26.1 272.4 79.8 272.4 79.8 29.1 266.0 78.0 266.0 78.0 30.2 253.2 74.2 253.2 74.2 32.2
52340G1 4719 66.2 334.4 98.0 290.2 85.1 23.8 313.8 92.0 282.3 82.7 26.7 293.7 86.1 274.7 80.5 29.6 286.5 84.0 272.0 79.7 30.7 272.6 79.9 266.8 78.2 32.7
0.11 72 368.4 108.0 230.0 67.4 24.4 348.0 102.0 223.1 65.4 27.4 327.0 95.8 216.1 63.3 30.3 319.2 93.6 213.5 62.6 31.4 0.0 0.0 0.0 0.0 0.0
11600 62 314.0 92.0 314.0 92.0 23.4 296.5 86.9 296.5 86.9 26.3 278.6 81.6 278.6 81.6 29.3 271.7 79.6 271.7 79.6 30.3 269.5 79.0 269.5 79.0 32.6
5475 66.2 339.4 99.5 314.4 92.2 23.9 319.2 93.6 306.8 89.9 26.8 299.2 87.7 299.2 87.7 29.8 291.9 85.5 291.9 85.5 30.8 277.5 81.3 277.5 81.3 32.8
0.12 72 376.3 110.3 247.1 72.4 24.5 354.8 104.0 240.1 70.4 27.5 332.3 97.4 232.8 68.2 30.4 323.4 94.8 230.0 67.4 31.4 0.0 0.0 0.0 0.0 0.0
8400 62 334.2 98.0 318.4 93.3 26.0 315.3 92.4 309.9 90.8 29.4 296.5 86.9 296.5 86.9 33.0 289.6 84.9 289.6 84.9 34.4 276.1 80.9 276.1 80.9 36.8
3964 66.2 366.6 107.4 283.6 83.1 26.7 348.3 102.1 276.0 80.9 30.2 324.7 95.2 266.4 78.1 33.7 316.3 92.7 263.0 77.1 34.9 300.3 88.0 256.6 75.2 37.3
0.09 72 399.3 117.0 228.5 67.0 27.4 378.7 111.0 221.0 64.8 30.8 357.7 104.9 213.6 62.6 34.4 349.9 102.6 210.8 61.8 35.6 334.5 98.0 205.4 60.2 37.9
10800 62 347.6 101.9 347.6 101.9 26.3 328.7 96.4 328.7 96.4 29.7 309.5 90.7 309.5 90.7 33.3 302.4 88.6 302.4 88.6 34.6 288.5 84.6 288.5 84.6 37.0
52380G1
5097 66.2 379.6 111.3 322.3 94.5 27.0 356.7 104.5 313.4 91.8 30.4 334.4 98.0 304.8 89.3 33.9 326.4 95.7 301.8 88.5 35.1 311.0 91.2 296.0 86.8 37.5
0.11 72 417.4 122.3 256.3 75.1 27.7 395.3 115.9 248.7 72.9 31.2 372.6 109.2 241.0 70.6 34.7 364.1 106.7 238.2 69.8 35.9 347.2 101.8 232.6 68.2 38.1
13600 62 360.1 105.5 360.1 105.5 26.6 340.6 99.8 340.6 99.8 30.0 320.3 93.9 320.3 93.9 33.6 313.0 91.7 313.0 91.7 34.8 310.8 91.1 310.8 91.1 37.5
6418 66.2 388.6 113.9 365.0 107.0 27.2 366.5 107.4 356.7 104.5 30.6 344.3 100.9 344.3 100.9 34.1 336.1 98.5 336.1 98.5 35.3 320.1 93.8 320.1 93.8 37.6
0.13 72 431.8 126.6 286.6 84.0 28.0 407.9 119.5 278.8 81.7 31.4 382.1 112.0 270.4 79.3 34.9 372.0 109.0 267.2 78.3 36.1 352.7 103.4 261.0 76.5 38.3
3964 66.2 397.6 116.5 296.9 87.0 29.2 379.0 111.1 288.8 84.7 33.1 359.3 105.3 280.6 82.2 37.3 352.0 103.2 277.5 81.3 38.8 334.6 98.1 270.4 79.2 41.6
0.09 72 434.2 127.3 241.6 70.8 29.9 413.7 121.2 233.9 68.5 33.8 392.2 115.0 225.9 66.2 38.0 384.1 112.6 223.0 65.3 39.4 368.0 107.9 217.2 63.7 42.2
11800 62 385.8 113.1 385.8 113.1 29.0 365.4 107.1 365.4 107.1 32.8 344.5 101.0 344.5 101.0 37.0 336.8 98.7 336.8 98.7 38.6 321.6 94.3 321.6 94.3 41.4
52420G1 5569 66.2 425.1 124.6 354.1 103.8 29.7 399.4 117.0 344.0 100.8 33.5 374.3 109.7 334.3 98.0 37.6 365.3 107.1 330.9 97.0 39.1 348.1 102.0 324.4 95.1 41.8
0.11 72 463.4 135.8 281.1 82.4 30.5 440.1 129.0 273.1 80.0 34.4 416.2 122.0 264.9 77.6 38.5 407.3 119.4 262.0 76.8 39.9 389.4 114.1 255.9 75.0 42.6
13600 62 394.0 115.5 394.0 115.5 29.1 373.3 109.4 373.3 109.4 33.0 352.1 103.2 352.1 103.2 37.2 344.3 100.9 344.3 100.9 38.7 328.9 96.4 328.9 96.4 41.6
6418 66.2 429.8 126.0 380.5 111.5 29.8 404.9 118.7 371.1 108.8 33.6 380.5 111.5 362.0 106.1 37.7 371.8 109.0 358.7 105.1 39.2 354.6 103.9 352.3 103.2 41.9
0.13 72 473.7 138.8 300.5 88.1 30.7 449.5 131.7 292.4 85.7 34.6 424.6 124.5 284.2 83.3 38.7 415.2 121.7 281.2 82.4 40.1 396.4 116.2 275.1 80.6 42.7
10400 62 418.2 122.6 396.1 116.1 32.4 395.0 115.8 385.7 113.0 36.8 371.9 109.0 371.9 109.0 41.8 363.4 106.5 363.4 106.5 43.5 346.8 101.6 346.8 101.6 46.8
4908 66.2 458.8 134.5 353.2 103.5 33.3 436.5 127.9 343.9 100.8 37.8 408.5 119.7 332.4 97.4 42.5 397.9 116.6 328.1 96.2 44.2 377.7 110.7 320.0 93.8 47.3
0.09 72 500.9 146.8 285.3 83.6 34.3 475.6 139.4 276.0 80.9 38.8 449.1 131.6 266.6 78.1 43.4 439.4 128.8 263.1 77.1 45.0 420.4 123.2 256.5 75.2 48.0
13500 62 435.6 127.7 435.6 127.7 32.8 412.6 120.9 412.6 120.9 37.3 388.9 114.0 388.9 114.0 42.1 380.2 111.4 380.2 111.4 43.8 363.0 106.4 363.0 106.4 47.0
52500G1 6371 66.2 477.4 139.9 403.7 118.3 33.7 448.9 131.6 392.6 115.1 38.1 420.7 123.3 381.8 111.9 42.8 410.6 120.3 378.0 110.8 44.4 391.3 114.7 370.7 108.7 47.5
0.11 72 525.2 153.9 321.4 94.2 34.9 497.5 145.8 311.8 91.4 39.3 469.0 137.5 302.2 88.6 43.9 458.5 134.4 298.6 87.5 45.5 437.9 128.3 291.8 85.5 48.3
16800 62 450.7 132.1 450.7 132.1 33.1 427.0 125.1 427.0 125.1 37.6 402.4 117.9 402.4 117.9 42.4 392.9 115.1 392.9 115.1 44.1 390.5 114.4 390.5 114.4 47.4
7929 66.2 488.1 143.0 453.9 133.0 34.0 460.4 134.9 443.5 130.0 38.4 432.6 126.8 432.6 126.8 43.1 422.3 123.8 422.3 123.8 44.7 402.3 117.9 402.3 117.9 47.6
0.13 72 542.7 159.1 357.1 104.6 35.3 512.9 150.3 347.4 101.8 39.7 481.9 141.2 337.3 98.9 44.3 469.4 137.6 333.3 97.7 45.8 445.6 130.6 325.6 95.4 48.5
10400 62 461.8 135.3 416.3 122.0 34.2 435.6 127.7 404.1 118.4 38.7 409.3 119.9 392.1 114.9 44.3 399.7 117.1 387.8 113.6 46.4 381.0 111.7 379.4 111.2 50.3
4908 66.2 498.3 146.0 370.0 108.4 34.8 475.9 139.5 360.4 105.6 39.6 451.5 132.3 350.1 102.6 45.1 442.1 129.6 346.2 101.5 47.1 421.4 123.5 337.7 99.0 50.8
0.09 72 546.2 160.1 302.3 88.6 35.8 521.3 152.8 293.0 85.9 40.6 493.7 144.7 282.6 82.8 45.9 482.9 141.5 278.7 81.7 47.9 461.7 135.3 271.1 79.4 51.5
15800 62 489.2 143.4 489.2 143.4 34.7 464.5 136.1 464.5 136.1 39.3 438.5 128.5 438.5 128.5 44.8 428.7 125.6 428.7 125.6 46.8 409.2 119.9 409.2 119.9 50.7
52550G1 7452 66.2 540.3 158.3 460.1 134.8 35.7 508.8 149.1 447.8 131.2 40.3 476.3 139.6 435.4 127.6 45.6 464.5 136.1 431.1 126.4 47.5 441.9 129.5 422.6 123.9 51.1
0.12 72 593.1 173.8 365.2 107.0 36.9 563.2 165.1 354.9 104.0 41.6 531.0 155.6 344.1 100.8 46.8 519.0 152.1 340.1 99.7 48.6 495.1 145.1 332.3 97.4 52.1
16800 62 493.8 144.7 493.8 144.7 34.8 469.0 137.4 469.0 137.4 39.4 442.7 129.7 442.7 129.7 44.9 432.8 126.8 432.8 126.8 46.9 413.0 121.0 413.0 121.0 50.7
7929 66.2 543.0 159.1 474.7 139.1 35.8 511.8 150.0 462.9 135.7 40.4 479.7 140.6 450.8 132.1 45.6 468.0 137.1 446.4 130.8 47.6 445.4 130.5 437.9 128.3 51.2
0.13 72 598.8 175.5 375.8 110.1 37.0 568.4 166.6 365.6 107.2 41.7 535.6 157.0 354.7 104.0 46.9 523.1 153.3 350.7 102.8 48.7 499.2 146.3 342.9 100.5 52.2

Table 7

Notes:
1. See Page 2 for legend.
2. Ratings are based on 84.2°F (29°C) DB evaporator air entering temperature.
3. Direct interpolation is permissible. Do not extrapolate.
4. SKM Computer Selection Software are available for quick and accurate selections.
5. Capacity is gross capacity which does not include the effect of evaporator fan motor heat.
* Power input (PI) mentioned in this page is for compressor only and should not be used for cable or fuse selection.
MCA and MFA values given in the electrical data (page 14) should be referred for the same.

12
FAN PERFORMANCE R 22
REFRIGERANT
External Static Pressure - in.wg (Pa)
Internal Static
Model AirFlowRate
Pressure 0.2(50) 0.4(100) 0.5(125) 0.6(150) 0.8(200) 1(250) 1.2(300)
APMR
cfm l/s in.wg Pa RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW
1600 755 0.28 70 653 0.19 756 0.24 805 0.26 852 0.29 945 0.34 1035 0.4 1125 0.47
51055G1 1700 802 0.31 78 678 0.22 777 0.27 823 0.3 868 0.32 957 0.38 1043 0.44 1128 0.51
2600 1227 0.73 183 944 0.68 1015 0.76 1049 0.8 1083 0.84 1147 0.92 1209 1 1270 1.08
1600 755 0.28 70 - - 662 0.21 711 0.25 759 0.28 - - - - - -
51070G1 2100 991 0.47 117 665 0.31 749 0.37 790 0.41 829 0.45 905 0.52 978 0.61 1050 0.7
2600 1227 0.73 183 791 0.55 862 0.63 896 0.67 929 0.71 994 0.8 1056 0.89 1117 0.99
2500 1180 0.29 72 607 0.34 692 0.42 732 0.46 770 0.5 843 0.57 912 0.66 979 0.74
51080G1 2800 1321 0.36 89 655 0.45 734 0.54 771 0.58 807 0.63 876 0.71 941 0.8 1003 0.89
4000 1888 0.74 185 881 1.2 938 1.32 967 1.38 995 1.45 1049 1.57 1101 1.7 1151 1.82
2500 1180 0.29 72 474 0.25 556 0.33 594 0.38 632 0.43 704 0.53 - - - -
51090G1 3200 1510 0.46 115 558 0.46 627 0.56 659 0.61 691 0.66 751 0.78 810 0.9 867 1.03
4000 1888 0.74 185 670 0.83 727 0.95 755 1.02 781 1.08 833 1.21 883 1.35 931 1.49
2500 1180 0.29 72 474 0.25 556 0.33 594 0.38 632 0.43 704 0.53 - - - -
51100G1 3500 1652 0.56 139 599 0.58 663 0.69 693 0.74 723 0.8 780 0.92 834 1.05 888 1.18
4000 1888 0.74 185 670 0.83 727 0.95 755 1.02 781 1.08 833 1.21 883 1.35 931 1.49
3000 1416 0.29 72 486 0.33 563 0.43 598 0.47 633 0.52 698 0.63 760 0.74 821 0.87
51120G1 4100 1935 0.53 132 608 0.74 669 0.86 698 0.92 726 0.98 780 1.11 832 1.25 881 1.38
4800 2265 0.74 185 695 1.15 749 1.29 775 1.36 800 1.43 848 1.57 895 1.72 940 1.88
3700 1746 0.28 71 - - 698 0.56 746 0.62 792 0.69 881 0.85 967 1.02 1052 1.22
52130G1 4500 2124 0.41 101 676 0.69 765 0.84 807 0.92 847 1 925 1.16 1000 1.34 1072 1.53
5900 2784 0.72 178 841 1.43 912 1.63 946 1.73 980 1.83 1044 2.03 1106 2.23 1166 2.45
3700 1746 0.28 71 - - 698 0.56 746 0.62 792 0.69 881 0.85 967 1.02 1052 1.22
52150G1 5000 2360 0.5 126 733 0.91 814 1.08 853 1.16 891 1.25 963 1.42 1033 1.61 1100 1.8
5900 2784 0.72 178 841 1.43 912 1.63 946 1.73 980 1.83 1044 2.03 1106 2.23 1166 2.45
4300 2029 0.28 70 611 0.55 706 0.7 751 0.77 794 0.84 876 1 954 1.17 1030 1.35
52170G1 5800 2737 0.5 124 754 1.18 832 1.37 868 1.47 904 1.57 972 1.76 1037 1.96 1100 2.16
7000 3303 0.74 185 885 1.98 951 2.22 983 2.33 1014 2.45 1074 2.69 1131 2.92 1187 3.16
4300 2029 0.28 70 611 0.55 706 0.7 751 0.77 794 0.84 876 1 954 1.17 1030 1.35
52180G1 6200 2926 0.57 143 797 1.41 870 1.62 905 1.72 939 1.83 1004 2.04 1067 2.25 1127 2.46
7000 3303 0.74 185 885 1.98 951 2.22 983 2.33 1014 2.45 1074 2.69 1131 2.92 1187 3.16
4300 2029 0.28 70 611 0.55 706 0.7 751 0.77 794 0.84 876 1 954 1.17 1030 1.35
52210G1 6500 3067 0.63 158 830 1.61 900 1.83 934 1.94 966 2.05 1030 2.26 1090 2.48 1148 2.71
7000 3303 0.74 185 885 1.98 951 2.22 983 2.33 1014 2.45 1074 2.69 1131 2.92 1187 3.16
6000 2831 0.28 70 674 1.04 755 1.24 794 1.34 832 1.44 903 1.64 971 1.84 1035 2.05
52240G1 7000 3303 0.37 93 757 1.56 827 1.78 862 1.9 896 2.02 961 2.25 1023 2.49 1083 2.72
9700 4577 0.73 183 1006 3.9 1057 4.2 1083 4.35 1108 4.51 1159 4.83 1208 5.15 1257 5.48
6000 2831 0.28 70 508 0.71 588 0.91 626 1.01 662 1.12 730 1.34 796 1.59 860 1.85
52270G1 8000 3775 0.49 122 620 1.47 686 1.72 717 1.85 748 1.98 805 2.25 860 2.53 913 2.82
9700 4577 0.73 183 730 2.51 786 2.81 813 2.96 839 3.11 890 3.43 939 3.75 986 4.08
6000 2831 0.28 70 508 0.71 588 0.91 626 1.01 662 1.12 730 1.34 796 1.59 860 1.85
52300G1 9000 4247 0.63 156 684 2.04 744 2.31 772 2.46 800 2.6 854 2.89 905 3.2 954 3.51
9700 4577 0.73 183 730 2.51 786 2.81 813 2.96 839 3.11 890 3.43 939 3.75 986 4.08
7200 3398 0.28 70 529 0.99 605 1.21 640 1.33 673 1.45 737 1.69 797 1.94 855 2.21
52340G1 10000 4719 0.53 132 676 2.37 735 2.66 763 2.81 791 2.96 843 3.28 894 3.6 942 3.92
11600 5474 0.73 181 770 3.6 821 3.94 846 4.11 871 4.28 918 4.64 964 5 1008 5.36
8400 3964 0.28 70 436 1.05 500 1.33 530 1.48 560 1.64 617 1.98 672 2.35 727 2.77
52380G1 10800 5097 0.45 113 521 1.99 574 2.34 600 2.51 624 2.69 672 3.07 718 3.47 763 3.89
13600 6418 0.74 183 634 3.77 678 4.19 699 4.41 720 4.63 760 5.07 799 5.53 837 6
8400 3964 0.28 70 436 1.05 500 1.33 530 1.48 560 1.64 617 1.98 672 2.35 727 2.77
52420G1 11800 5568 0.54 136 560 2.53 610 2.91 634 3.1 657 3.29 701 3.69 745 4.11 786 4.55
13600 6418 0.74 183 634 3.77 678 4.19 699 4.41 720 4.63 760 5.07 799 5.53 837 6
10400 4908 0.28 71 465 1.58 524 1.91 551 2.07 577 2.24 628 2.6 676 2.97 723 3.37
52500G1 13500 6371 0.46 115 567 3.13 615 3.56 638 3.77 661 3.98 704 4.41 745 4.85 784 5.3
16800 7928 0.73 183 687 5.79 727 6.32 746 6.59 765 6.85 802 7.38 838 7.91 872 8.44
10400 4908 0.28 71 465 1.58 524 1.91 551 2.07 577 2.24 628 2.6 676 2.97 723 3.37
52550G1 15800 7456 0.64 161 650 4.86 692 5.36 713 5.61 733 5.86 771 6.36 808 6.86 844 7.36
16800 7928 0.73 183 687 5.79 727 6.32 746 6.59 765 6.85 802 7.38 838 7.91 872 8.44

Table 8
Notes:
1. Areas shaded in blue indicate factory setting of RPM.
2. Areas shaded in grey indicate operating range outside the standard motor. Shift to larger motor size in this area.
3. Internal static pressure is based on pressure drops through evaporator coil, fan casing and 1” flat filter.
4. The shown RPM range is with standard pulleys combination.

S.K.M Air Conditioning LLC


13
SKM Packaged Air Conditioners APMRG1 Series

ELECTRICAL DATA

Power Supply: 380~415V/3Ph/50Hz


Model Unit Characteristic Compressor Condenser Fan Motor Evaporator Fan Motor
APMR
MFA MCA ICF QTY RLA LRA QTY FLA LRA FLA LRA
51055G1 32 15 72 1 10 67 1 1.2 3.6 1.5 11.6
51070G1 40 20 105 1 14 100 1 1.2 3.6 1.5 11.6
51080G1 40 22 112 1 14 101 1 2.2 9.0 1.9 14.3
51090G1 40 25 107 1 16 95 1 2.2 9.0 2.7 16.5
51100G1 50 29 123 1 19 111 1 2.2 9.0 2.7 16.5
51120G1 50 31 131 1 20 118 1 2.2 9.0 3.6 22.5
52130G1 50 35 101 2 12 74 2 2.2 9.0 3.6 22.5
52150G1 63 40 129 2 14 100 2 2.2 9.0 3.6 22.5
52170G1 63 40 131 2 14 101 2 2.2 9.0 4.3 32.3
52180G1 63 45 127 2 16 95 2 2.2 9.0 4.3 32.3
52210G1 80 54 148 2 19 111 2 2.2 9.0 6.7 42.8
52240G1 80 56 156 2 20 118 2 2.2 9.0 6.7 42.8
52270G1 80 61 159 2 21 118 3 2.2 9.0 6.7 42.8
52300G1 100 70 185 2 25 140 3 2.2 9.0 6.7 42.8
52340G1 125 80 225 2 29 174 3 2.2 9.0 8.3 61.5
52380G1 125 89 282 1+1 34 + 29 229 + 174 4 2.2 9.0 8.3 61.5
52420G1 160 98 383 2 34 229 3 3.3 11.0 11.4 80.3
52500G1 160 108 392 1+1 42 + 34 320 + 229 3 3.3 11.0 11.4 80.3
52550G1 200 122 398 2 42 320 4 3.3 11.0 14.7 107.9

Table 9

Legend
MFA Maximum Fuse Amps (for fuse/circuit breaker sizing), RLA Rated Load Amps. (at worst operating condition)
complies with NEC Article 440-22 & 430-52. LRA Locked Rotor Amps
FLA Full Load Amps
MCA Minimum Circuit Amps.(for wire sizing), complies with NEC
article 440-33.
ICF Maximum Instantaneous Current Flow

Note : Voltage imbalance not to exceed ± 2 % of the rated voltage.

14
Field Connections
R 22
REFRIGERANT
APMRG1 series self-contained heavy duty air cooled packaged units are designed for minimum field interaction. Power hook ups and
control wiring of room thermostat as per field wiring diagrm is all that is required to electrically connect any model of APMRG1 series.
Every APMRG1 series packaged air conditioning unit requires, at most,field installed fused disconnect switches or circuit breakers
and room thermostat.

Refer below for schematic representation of required field electrical hook-ups for a standard APMRG1 series packaged air conditioning
unit. All field wiring must be done in accordance with applicable local & national codes.

For the maximum fuse ampere for fuse sizing & minimum circuit amps for cable sizing, see page 14.

The APMRG1 series is then ready to provide cooling, on demand.

Field
Field Wiring Wiring Requirement
Requirement Schematic Schematic

L1 L2 L3 N

CIRCUIT BREAKER
OR FUSED
DISCONNECT SWITCH
(NOT BY SKM)

3 PHASE,
4WIRE SYSTEM
380-415V/3PH/50HZ

L1
L2
L3
N

GROUND

E
CONTROL TERMINAL
BLOCK

LINE VOLTAGE
FIELDWIRING (BY OTHERS)
APMR-G1 SERIES
COOLING STAGE-1 ON / OFF
COOLING STAGE-2 ON / OFF
EVAPORATOR FAN ON / OFF

CONTROL PANEL LOW VOLTAGE


FIELDWIRING (BY OTHERS)
24V AC

REFER ACTUAL WIRING DIAGRAM


FURNISHED WITH THE UNIT FOR
EXACT IDENTIFICATION OF WIRE NUMBERS.

TYPICAL ROOM THERMOSTAT ( BY OTHERS )


( 1 STAGE OR 2 STAGE - COOLING OR COOLING & HEATING )

S.K.M Air Conditioning LLC


15
16
LEGEND
_____ FIELD CONNECTIONS & FIELD
FDS ( BY OTHERS )
SUPPLIED DEVICES
POWER SUPPLY (V/Ph/hZ)
-XM FDS FUSED DISCONNECT SWITCH
L1
LPS LOW PRESSURE SWITCH
L2
HPS HIGH PRESSURE SWITCH
L3
CS CONTROL SWITCH
N
CCH CRANK CASE HEATER
E
-K1 -K2 F MINIATURE CIRCUIT BREAKER
EFM EVAPORATOR FAN MOTOR
-OLR OLR OVER LOAD PROTECTOR
CFM CONDENSER FAN MOTOR
CM COMPRESSOR MOTOR
K CONTACTOR
XM POWER TERMINAL BLOCK
X2 CONTROL TERMINALS BLOCK
-F SV SOLENOID VALVE
TFR TRANSFORMER
M M M TK THERMAL OVERLOAD PROTECTION
3~ 3~ 3~

-CM -CFM
EFM
-K1 -K2
CM+CFM EFM
SKM Packaged Air Conditioners

SEC1

-ECB
-X2

CM1
P1
IN-FAN
HTR1
HTR2
X1
O-FAN1

-DOs
ID

P-COM1
OD

-TFR
Typical Wiring Diagram (WITH SINGLE COMPRESSOR)

CCH
BLK
BLK
WHITE
WHITE

RLY1
RLY2
RLY3
RLY4
RLY5
RLY6
RLY7

ECB
SEC1

10V 24V

S1 DIP SWITCH
TFR

SEQ. CONTROL
4
3
2
1

220~
PRI1

ON OFF 240VAC
RED
RED

* 1 TEST MODE NORMAL MODE


ON
T5A L250V
2 COMP.1 LEAD BALANCE MODE
OFF 1 2 3 4 3 PDS ENBL PDS DISBL
-K1
S1 4 SINGLE STAGE * DUAL STAGE
F1

POWER DIs THERMOS


N
ON/OFF ON/OFF HP1 HP1 LP1 LP1
R C G Y1 Y2 W1 W2
L
APMRG1 Series

-S P
ON/OFF P X2
-LPS
-HPS
-OLR R C G Y
THERMOSTAT
LEGEND
_____ FIELD CONNECTIONS & FIELD
FDS ( BY OTHERS )
-XM POWER SUPPLY (V/Ph/hZ) SUPPLIED DEVICES
L1 FDS FUSED DISCONNECT SWITCH
L2
LPS LOW PRESSURE SWITCH
L3
SS HPS HIGH PRESSURE SWITCH
N

E
CS CONTROL SWITCH
CCH CRANK CASE HEATER
-K5
-K1 -K2 F MINIATURE CIRCUIT BREAKER
-K3 -K4
-OLR1 EFM EVAPORATOR FAN MOTOR
OLR OVER LOAD PROTECTOR
CFM CONDENSER FAN MOTOR
CM COMPRESSOR MOTOR
K CONTACTOR
XM POWER TERMINAL BLOCK
-F
X2 CONTROL TERMINALS BLOCK
M M
M M 3~ 3~ M SV SOLENOID VALVE
3~ 3~ Θ Θ 3~
-CFM2 TFR TRANSFORMER

TK1.1
TK1.2
TK2.1
TK2.2
TK THERMAL OVERLOAD PROTECTION
-CM1 -CM2 -EFM
-CFM1 -CFM2

-K1 -K2 -K5 -K3 -K4


CFM1 CFM2
CM1 CM2 EFM
TK1.2 TK2.2

TK1.1 TK2.1

P P

SEC1

-FCS1 -FCS2

-ECB
CM1
CM2
P1
P2
IN-FAN
HTR1
HTR2
X1
X2
O-FAN1
O-FAN2

-DOs
ID

P-COM1
OD

-X2 -TFR
Typical Wiring Diagram (WITH DOUBLE COMPRESSOR)

BLK
BLK
WHITE
WHITE

RLY1
RLY2
RLY3
RLY4
RLY5
RLY6
RLY7
RLY8
RLY9
RLY10
RLY11

ECB
SEC1

10V 24V

S1 DIP SWITCH
TFR

SEQ. CONTROL
4
3
2
1

220~
PRI1

ON OFF 240VAC
RED
RED

1 TEST MODE NORMAL MODE


ON

CCH1
T5A L250V

-CCH2
2 COMP.1 LEAD BALANCE MODE
OFF 1 2 3 4 3 PDS ENBL PDS DISBL

S1 4 SINGLE STAGE DUAL STAGE


R 22

F1

-K1 -K2
REFRIGERANT

POWER DIs THERMOS


N1
ON/OFF ON/OFF HP1 HP1 HP2 HP2 LP1 LP1 LP2 LP2
R C G Y1 Y2 W1 W2
L1

P P P P
-S X2
ON/OFF -HPS1 -HPS2 -LPS1 -LPS2

-OLR1
R C G Y1 Y2
THERMOSTAT

17
S.K.M Air Conditioning LLC
SKM Packaged Air Conditioners APMRG1 Series

Dimensional Data
APMR Model - 51055G1APMR 51055G1
03 LEGEND
A1
A3
APMR 51055G1 01 CONTROL PANEL
02 COMPRESSOR
[50]
2

03 CONDENSER FAN
04 03 04 CONDENSER COIL
LEGEND
A1
A3 05 EVAPORATOR COIL
01 CONTROL PANEL
06 EVAPORATOR FAN
02 COMPRESSOR
07 EVAPORATOR FAN MOTOR
[50][50]
2 2

03 CONDENSER FAN
08 1" THICK FLAT FILTER
04 04 CONDENSER COIL
ALL EVAPORATOR
05DIMENSIONS ARECOIL
IN INCHES[mm]
A4
F 06 EVAPORATOR
A1-A4 ARE LOADINGFANPOINTS
A2
DRAIN F=4.7 [120] FOR 1" FLAT
07 EVAPORATOR FILTER(STANDARD)
FAN MOTOR
2 x FPT 3/4 [19] F=5.7
08 1"[145] FORFLAT
THICK 2"FLAT FILTER(OPTIONAL)
FILTER
[50]
2

45
ALL DIMENSIONS[1143]
ARE IN INCHES[mm]
50.8 A4
F A1-A4 ARE LOADING POINTS
A2 [1291] 38
DRAIN F=4.7 [120] FOR 1" FLAT FILTER(STANDARD)
19.7 1 [965]
2 x FPT 3/4 [19] F=5.7 [145] FOR 2"FLAT FILTER(OPTIONAL)
[500] [25] 13.03

[20]
AIR OUT 45

1
07 06 [331]
[1143]
50.8
[1291] 38

7.5 1 11.38
[190] [289]
01 19.7 1 [965]
[500] S/A[25] 13.03

[20]
AIR OUT [331]
07 06
AIR IN
[1069]
[1186]

[1131]
42.1
46.7

44.5

11.38
[289]

01
R/A
[559]

02 S/A
7.5 22
[190]

AIR IN
[1069]
[1186]

[1131]
42.1
46.7

44.5

R/A
[559]

02 05 08
22
[62]

[73]
2.4

2.9

POWER SOURCE ACCESS PANEL


HOLES Ø 1.2 [31] FOR COMPRESSOR
ACCESS PANEL
CONTROL CIRCUIT ON BOTH SIDES
HOLES Ø 0.8 [20]
05 08
[62]

[73]
2.4

2.9

POWER SOURCE ACCESS PANEL


APMR 51070G1 [31]
HOLES Ø 1.2 FOR COMPRESSOR
ACCESS PANEL
CONTROL CIRCUIT
APMR Model -HOLES
51070G1
03 ON BOTH SIDES
Ø 0.8 [20] A1
A3

APMR 51070G1
[50]
2

04 03
A1
A3
[50][50]
2 2

04

A4
A2 F 45
DRAIN
[1143]
[50]

2 x FPT 3/4 [19]


2

38
54.8
[1391] A4 [965]
A2 23.6 1
F 15.55
[600] [25] 45
[20]

AIR OUT DRAIN [395]


1

07 06 [19] [1143]
2 x FPT 3/4
38
54.8
[1391] [965]
01
11.422 13.43 11.4 1 13.43
[559] [341] [291] [20][341]

23.6 1
S/A 15.55
[600] [25]
AIR OUT [395]
07 06
[1222]
[1339]

[1284]
48.1
52.7

AIR IN
50.5

01
S/A
R/A
02
[291]
[1222]
[1339]

[1284]
48.1
52.7

AIR IN
50.5

R/A
[559]

02 05 08
22
[62]

[73]
2.9
2.4

ACCESS PANEL
POWER SOURCE ACCESS PANEL ON BOTH SIDES
HOLES Ø 1.2 [31] FOR COMPRESSOR
CONTROL CIRCUIT
HOLES Ø 0.8 [20]
05 08
[62]

[73]
2.9
2.4

ACCESS PANEL
POWER SOURCE ACCESS PANEL ON BOTH SIDES
HOLES Ø 1.2 [31] FOR COMPRESSOR
CONTROL CIRCUIT
HOLES Ø 0.8 [20]

18
Dimensional Data R 22
REFRIGERANT
APMR Models - 51080G1 to 51120G1
APMR 51080G1 - 51120G1

A1 03
A3
APMR 51080G1 - 51120G1
DIMENSIONS
Model
[50]
2

A1 03 APMR
A3 L W A B C D J G H

60.2 47 40 32 11.3 23.6 13.43 15.55 60.4


04 51080G1
[50]

[1530] [1194] [1016] [813] [288] [600] [341] [395] [1535]


2

51090G1
63 47 40 32 8.9 26.4 15.91 18.54 60.5

Table 10
04 [1600] [1194] [1016] [813] [225] [670] [404] [471] [1536]
51100G1
[50]
2

A4 63 55 48 32 8.9 26.4 15.91 18.54 60.5


51120G1
A2 F [1600] [1397] [1219] [813] [225] [670] [404] [471] [1536]
ALL DIMENSIONS ARE IN INCHES[MM]
[50]

DRAIN
2

2 x FPT 3/4 [19]


A4 W
L 1
A2 F
[25] A
DRAIN
36.6 D 3/4 [19]
2 x FPT
[930] W
G

[20]
L 1

1
06
AIR OUT [25] A
36.6 D
[930] G

[20]
1J
06 S/A
AIR OUT
01

C
J
S/A
[1536]
60.5

H
[1222]

AIR01IN
48.1

B C
R/A
[1536]

02
60.5

H
[1222]
48.1

AIR IN

R/A
B

02
07 05 08
[62]

[73]
2.4

2.9

POWER SOURCE ACCESS PANEL


HOLES Ø 1.2 [31] FOR COMPRESSOR ACCESS PANEL
CONTROL CIRCUIT ON BOTH SIDES
HOLES Ø 0.8 [20] 07 05 08
[62]

[73]
2.4

2.9

POWER SOURCE ACCESS PANEL


HOLES Ø 1.2 [31] FOR COMPRESSOR ACCESS PANEL
CONTROL CIRCUIT ON BOTH SIDES
HOLES Ø 0.8 [20]
APMR 52130G1 & 52150G1

APMR Models - 52130G1 &4-Ø0.79


52150G1
[20] HOLES
10
[254]
10
[254] LEGEND
APMR 52130G1 & 52150G1 FOR ANCHOR BOLTS
A1 A3 01 CONTROL PANEL
04
10 10 02 COMPRESSOR
[254]
4-Ø0.79 [20] HOLES
[254] LEGEND
03 CONDENSER FAN
FOR ANCHOR BOLTS
A1 A3
04 CONTROL
01 CONDENSER PANEL
COIL
04 05 COMPRESSOR
02 EVAPORATOR COIL
06 CONDENSER
03 EVAPORATORFAN FAN
01
POWER
SOURCE
CONTROL
CIRCUIT
04
07 CONDENSER
EVAPORATORCOIL FAN MOTOR
DETAIL AT `A' 08 EVAPORATOR
05 1" THICK FLAT COIL
FILTER
01 09 EVAPORATOR
06 FAN
FORKLIFTING POCKET
POWER CONTROL
SOURCE CIRCUIT 07 EVAPORATOR FAN MOTOR
03 ALL DIMENSIONS
DETAIL AT `A' 08 1" THICK FLATARE IN INCHES
FILTER
A1-A4 ARE LOADING
09 FORKLIFTING POINTS [mm]
POCKET
F=4.7 [120] FOR 1" FLAT FILTER(STANDARD)
03 ALL DIMENSIONS ARE IN INCHES
F=5.7 [145] FOR 2"FLAT FILTER(OPTIONAL)
A2 A4 F
A1-A4 ARE LOADING POINTS [mm]
75
DRAIN F=4.7 [120][1905]
FOR 1" FLAT FILTER(STANDARD)
2 x FPT 1 [25]
F=5.7 [145] 60
FOR 2"FLAT FILTER(OPTIONAL)
A2 A4 F
75 1 [1524]
75
[1905] DRAIN [25] [1905]
282 x FPT 1 [25] 43.7
[711] [1109]
[38]

60
1.5

07 06
75 1 [1524]
[1905] [25]
28 43.7
13.43
[341]
[183]

[711] [1109]
7.2

[38]
1.5

07 06 S/A

08
13.43
[341]
[183]
7.2
[1578]

S/A
[1515]
62.1

59.6
[1227]

AIR IN
48.3

R/A
[813]

08
32
[1578]

[1515]
[126]
62.1

59.6
[1227]

AIR
A IN
5
48.3

R/A
[813]
32
[126]

A
5

02 09 05
[140]

[100]
3.94
5.5

RIGGING HOLES
Ø0.79 [20] x 4Nos. ACCESS PANEL
ON BOTH SIDES
02 09 05
[140]

[100]
3.94
5.5

RIGGING HOLES
Ø0.79 [20] x 4Nos. ACCESS PANEL
ON BOTH SIDES

S.K.M Air Conditioning LLC


19
SKM Packaged Air Conditioners APMRG1 Series

APMR 52170G1, 52180G1, 52210G1 & 52240G1

Dimensional Data 10 4-Ø0.79 [20] HOLES 10


LEGEND
01 CONTROL PANEL
ALL DIMENSIONS ARE IN INCHES[mm]
[254] FOR ANCHOR BOLTS [254] A1-A4 ARE LOADING POINTS
APMR Models - 52170G1 to 52240G1
A1 A3 02 COMPRESSOR
F=4.7 [120] FOR 1" FLAT FILTER(STANDARD)
03 CONDENSER FAN
APMR 52170G1, 52180G1, 52210G1 & 52240G1
04 F=5.7 [145] FOR 2"FLAT FILTER(OPTIONAL)
04 CONDENSER COIL
LEGEND MODEL 52240G1 EVAPORATOR COIL INCLINED TYPE ARRANGEMENTS
05 EVAPORATORALL COIL
DIMENSIONS ARE IN INCHES[mm]
10 4-Ø0.79 [20] HOLES 10 01 CONTROL PANEL
[254] A1 FOR ANCHOR BOLTS A3 [254] 06 EVAPORATORA1-A4
FAN ARE LOADING POINTS
02 COMPRESSOR
07FAN
03 CONDENSER FAN[120]
EVAPORATORF=4.7 MOTORFOR 1" FLAT FILTER(STANDARD)
F=5.7 [145] FOR 2"FLAT FILTER(OPTIONAL)
04 08COIL
04 CONDENSER 1" THICK FLAT FILTER CONTROL
01 MODEL 52240G1 EVAPORATOR COILSOURCE INCLINED TYPE
POWER
ARRANGEMENTS
CIRCUIT
09 COIL
05 EVAPORATOR FORKLIFTING POCKETS DETAIL AT `A'
06 EVAPORATOR FAN
* ADD 3MM MORE FOR MODEL 52240G1
07 EVAPORATOR FAN MOTOR
08 1" THICK FLAT FILTER POWER CONTROL
01 SOURCE CIRCUIT
09 FORKLIFTING POCKETS DETAIL AT `A'
03
DIMENSIONS
Model
APMR
03 L A B C D H
A2 A4 F 91 70 32 7.2 28 59.6

Table 11
52170G1 / 52180G1 /
DRAIN
2 x FPT 1 [25] 52210G1 [2311] [1778] [813] [182] [711] [1515]
A2 A4 F 95 78 35.6 9.3 32 65.47
DRAIN
52240G1 88
[2413] [1981] [904] [236] [813] [1663]
2 x FPT 1 [25] [2235]
L ALL DIMENSIONS ARE IN INCHES[MM]
88 A
[2235]
63L D 1
[1600] [25] A = 43.7 =

[38]
63 AIR OUT D 1 [1109]

1.5
[1600] [25] = 43.7 =
06 [38]
[1109]
1.5

AIR OUT 07
06

13.43
C
07

[341]
S/A
13.43
C

[341]

S/A
*
08
[1578]

08
62.1
[1578]

[1227]
62.1

AIRAIR
IN IN
48.3
[1227]

H
48.3

H
R/A R/A
B
[126] B
[126]
5

A A

02 09 05
[140]

02 09 ACCESS PANEL
[100]

5.5

05
3.94

RIGGING HOLES
[140]

ON BOTH SIDES
[100]

Ø0.79 [20] x 4Nos.


5.5

ACCESS PANEL
3.94

RIGGING HOLES
Ø0.79 [20] x 4Nos. ON BOTH SIDES

APMR 52270G1, 52300G1 & 52340G1

APMR Models - 52270G1 to 52340G1 APMR 52270G1, 52300G1 & 52340G1

10 10
[254]
4-Ø0.79 [20] HOLES [254]
FOR ANCHOR BOLTS
A1 A3
10 10
[254]
4-Ø0.79 [20] HOLES [254]
FOR ANCHOR BOLTS
01 A1 A3 DIMENSIONS
Model APMR
L M D B C H
01
105.6 73 32.6 40 9.7 72.65
52270G1 / 52300G1
Table 12

[2682] [1854] [828] [1016] [247] [1845]


CABLE ENTRY 116 81 35 42.5 10.66 76.1
52340G1
[2946] [2057] [889] [1080] [271] [1933]
ALL DIMENSIONS ARE IN INCHES[MM]
MODEL 52340G1 EVAPORATOR COIL INCLINED TYPE ARRANGEMENTS

CABLE ENTRY 88
A2 A4 F [2235]

DRAIN 78
2 x FPT 1 [25] MODEL 52340G1
[1981] EVAPORATOR COIL INCLINED TYPE ARRANGEMENTS
L

M D 1 = 52.3 =
[1328] 88
[25]
03 A2 07
A4 F [2235]
[38]

06
1.5

DRAIN 78
2 x FPT 1 [25] [1981]
15.91
[404]

L S/A

M D 1 = 52.3 =
C

[25] [1328]
03 07 08
[38]

06
[1951]

1.5
76.8

[1600]

H
63

R/A
B

15.91
[404]

S/A
[126]
5

A
05
C

02 09 04 08
[1951]

[100]

[140]
633.94
76.8

5.5
[1600]

RIGGING HOLES ACCESS PANEL


Ø0.79[20] x 4Nos.
H

ON BOTH SIDES

R/A
B
[126]
5

A
05

02 09 04
[100]

[140]
3.94

5.5

RIGGING HOLES ACCESS PANEL


Ø0.79[20] x 4Nos. ON BOTH SIDES

20
Dimensional Data R 22
REFRIGERANT
APMR Model - 52380G1MODEL :- APMR-52380G1
MODEL :- 10 APMR-52380G1 55 55 10
[254] [1397] [1397] [254]
6-Ø0.79 [20] HOLES A1 A3 A5 LEGEND
FOR ANCHOR BOLTS 01 CONTROL PANEL
10 55 55 10 02 COMPRESSOR
[254] 01 [1397] [1397] [254] 03 CONDENSER FAN
6-Ø0.79 [20] HOLES A1 A3 A5 LEGEND
FOR ANCHOR BOLTS 04 CONDENSER COIL
01 CONTROL PANEL
05 EVAPORATOR COIL
02 COMPRESSOR
06 EVAPORATOR FAN
01 03 CONDENSER FAN
POWER CONTROL 07 EVAPORATOR FAN MOTOR
SOURCE CONDENSER COIL
04 CIRCUIT
DETAIL AT `A' 08 1" THICK FLAT FILTER
CABLE ENTRY 05 EVAPORATOR COIL
06 EVAPORATOR FAN
POWER CONTROL 07 EVAPORATOR FAN MOTOR
ALL DIMENSIONS ARE IN INCHES[mm]
SOURCE CIRCUIT
DETAIL AT `A' 08 1" THICK FLAT
F=4.72 FILTER
[120] FOR 1" FLAT FILTER(STANDARD)
CABLE ENTRY
F=5.7 [145] FOR 2"FLAT FILTER(OPTIONAL)
88
ALL DIMENSIONS ARE IN INCHES[mm]
[2235]
A2 A4 A6 F=4.72 [120] FOR 1" FLAT FILTER(STANDARD)
F
DRAIN 78
F=5.7 [145] FOR 2"FLAT FILTER(OPTIONAL)
2 x FPT 1 [25] [1981]
130 88
[3302] = [2235] 61.89 =
A2 87
A4 A6 43 1

[38]
1.5
F [1572]
[2210] 06
DRAIN [1092] [25] 78
[25]
03 130 072 x FPT 1 [1981]
[3302] = 61.89 =

18.82
[478]
87 43 1

[38]
1.5
S/A [1572]
[2210] 06 [1092] [25]
07

[270]
03

10.63
18.82
[478]
S/A
08

[2208]
86.9
[1976]

[270]
77.8

10.63
[1600]
63

[1257]
49.5
08 R/A

[2208]
86.9
[1976]
77.8

[1600]

A
63

[1257]
49.5

R/A

A RIGGING HOLES 02 04 05
[125]

[165]
4.9

6.5

Ø0.79 [20] x 4Nos. ACCESS PANEL


ON BOTH SIDES

RIGGING HOLES 02 04 05
[125]

[165]
4.9

6.5

Ø0.79 [20] x 4Nos. ACCESS PANEL


ON BOTH SIDES
MODEL :- APMR-52420G1
APMR Models - 52420G1
10 55 55 10
MODEL :- APMR-52420G1
LEGEND [254]
A1
[1397]
A3
[1397]
A5
[254]
6-Ø0.79 [20] HOLES
01 CONTROL PANEL FOR ANCHOR BOLTS
02 COMPRESSOR 10 55 55 10 ACCESS
03 CONDENSER FAN [254] [1397] [1397] [254]
LEGEND 6-Ø0.79 [20] HOLES A1 A3 A5
04 CONDENSER COIL
01 CONTROL PANEL FOR ANCHOR BOLTS
05 EVAPORATOR COIL
02 COMPRESSOR POWER CONTROL
ACCESS
06 EVAPORATOR FAN SOURCE CIRCUIT
DETAIL AT `A'
03 CONDENSER FAN
07 EVAPORATOR FAN MOTOR
04 CONDENSER COIL
08 1" THICK FLAT FILTER
05 EVAPORATOR COIL CONTROL
POWER
06 EVAPORATOR FAN SOURCE CIRCUIT
DETAIL AT `A'
07 EVAPORATOR FAN MOTOR
ALL DIMENSIONS ARE IN INCHES[mm]
08 1" THICK FLAT
F=4.72 FILTER
[120] FOR 1" FLAT FILTER(STANDARD)
F=5.7 [145] FOR 2"FLAT FILTER(OPTIONAL)

ALL DIMENSIONS ARE IN INCHES[mm] 88


A2 A4 A6
F=4.72 [120] FOR 1" FLAT FILTER(STANDARD)
[2235] DRAIN Ø1 1/4 [32] x2Nos.
F=5.7 [145] FOR 2"FLAT FILTER(OPTIONAL) F 130
78
[1981] [3302]
88
[2235] 61.89 1A2 43 A4 87 A6
DRAIN Ø1 1/4 [32] x2Nos.
[38]

[25] [1092] [2210]


1.5

[1572] F 130
78 06 07
[3302] 03
[1981]
61.89 1 43 87
18.82
[478]
[38]

[25] [1092] [2210]


1.5

[1572] S/A 01
06 07
03
10.63
[270]
18.82
[478]

S/A 01
08
[2208]
86.9

[2110]
83.1
10.63
[270]

[1257]
49.5

08 R/A
[2208]
86.9

[2110]
83.1

A
[1257]
49.5

R/A

08 05 A RIGGING HOLES
04 02 Ø.79[20] 4 Nos.
[125]

[165]
4.9

6.5

ACCESS PANEL
BOTH SIDES
08 05 RIGGING HOLES
04 02 Ø.79[20] 4 Nos.
[125]

[165]
4.9

6.5

ACCESS PANEL
BOTH SIDES

S.K.M Air Conditioning LLC


21
SKM Packaged Air Conditioners APMRG1 Series

Dimensional Data
APMR Model - 52500G1MODEL:- APMR-52500G1
MODEL:- APMR-52500G1

10 55 55 10
LEGEND 10 [254] 55 [1397] 55 [1397] 10 [254]
[254] A1[1397] A3[1397] A5
[254]
LEGEND 01 CONTROL PANEL
A1 A3 A5
01 CONTROL PANEL
02 COMPRESSOR ACCESS
02 COMPRESSOR
03 CONDENSER FAN ACCESS
03 CONDENSER FAN
04 CONDENSER COIL
04 CONDENSER COIL
05 EVAPORATOR COIL
POWER CONTROL
05 EVAPORATOR COIL
06 EVAPORATOR FAN SOURCE CIRCUIT
POWER DETAIL
CONTROL AT `A'
CIRCUIT
06 EVAPORATOR FAN
07 EVAPORATOR SOURCE
FAN MOTOR DETAIL AT `A'
07 EVAPORATOR FAN MOTOR
08 1" THICK FLAT FILTER
08 1" THICK FLAT FILTER
ALL DIMENSIONS ARE IN INCHES [mm]
F=4.72[120]
ALL DIMENSIONS ARE IN INCHES
FOR [mm]
1" FLAT FILTER(STANDARD)
F=4.72[120]
F=5.7[145]
FOR 1" FLAT
FOR FILTER(STANDARD)
2"FLAT FILTER(OPTIONAL)
F=5.7[145] FOR 2"FLAT FILTER(OPTIONAL)

A2 A4 A6
F A2 DRAIN Ø1 1/4 [32] x2Nos.
A4 130 A6
88
88 [2235] F DRAIN Ø1 1/4 [32] x2Nos. 130 [3302]
[2235] [3302]
75
75 [1905]
[1905] 61.9 [38] 1 43 87
1.5

61.9 [1572] 1 [25] 43 [1092] 87 [2210]


[38]
1.5

[1572] [25] [1092] [2210]


03
[478]
18.8

03
[478]
18.8

01
01
[102]
4
[102]
4
[2622]
103.24
[2622]
103.24

[2313]
91.1
[1839]

[2313]
72

91.1
[1839]
72
[125]
4.92

A
[125]
4.92

08
05 04
[50]

08 06 07 02
05 RIGGING HOLES
2

04
[50]

06 07 ACCESS PANEL 02 Ø.79 [20] 4 Nos.


RIGGING HOLES
2

BOTH SIDES
ACCESS PANEL Ø.79 [20] 4 Nos.
BOTH SIDES

MODEL:- APMR-52550G1
APMR Model - 52550G1
MODEL:- APMR-52550G1

10 10
10 [254] 10 [254]
[254] [254]
A1 A3 A5
A1 A3 A5

LEGEND
LEGEND 1 CONTROL PANEL
1 CONTROL PANEL
2 COMPRESSOR
2 COMPRESSOR
3 CONDENSER FAN
3 CONDENSER FAN
4 CONDENSER COIL
4 CONDENSER COIL
5 EVAPORATOR COIL
5 EVAPORATOR COIL
6 EVAPORATOR FAN
6 EVAPORATOR FAN
7 EVAPORATOR FAN MOTOR
7 EVAPORATOR FAN MOTOR
8 1" THICK FLAT FILTER
8 1" THICK FLAT FILTER
ALL DIMENSIONS ARE IN INCHES [MM]
F=4.72 [120]
ALL DIMENSIONS ARE FOR 1" FLAT
IN INCHES FILTER(STANDARD)
[MM]
A2 A4 A6
F=4.72 [120]
F=5.7 [145]
FOR 1" FLAT
FOR FILTER(STANDARD)
2"FLAT FILTER(OPTIONAL)
F A2 DRAIN Ø1 1/4 [32] x2Nos.A4 A6
F=5.7 [145] FOR 2"FLAT FILTER(OPTIONAL)
F DRAIN Ø1 1/4 [32] x2Nos.
88
88 [2235]
137.5
[2235] 75
137.5 [3493]
75 [1905]
1 43 [3493] 94.5
[1905] 61.9
1 [25] 43 [1092] 94.5 [2401]
61.9 [1572] 3
[25] [1092] [2401]
[1572] 3
[38]
1.5

4
[38]
1.5

4
[478]
18.8
[478]
18.8

1
1
[144]
5.7
[144]

[2948]
5.7

116.1
[2540]
[2665]

[2948]
100
116.1
105

[2540]
[2665]

100
105

[1829]
72
[1829]
72

DETACHABLE
PLATE FOR
DETACHABLE
CABLE ENTRY
PLATE FOR
CABLE ENTRY

8
8 5
[50]

6 7 2
[125]

2
4.92

5 RIGGING HOLES STEEL WIRE


[50]

6 7 2 Ø.79[20] 4 Nos.
[125]

ACCESS PANEL
2
4.92

RIGGING HOLES STEEL WIRE


BOTH SIDES Ø.79[20] 4 Nos.
ACCESS PANEL
BOTH SIDES

22
Loading Points R 22
REFRIGERANT
MODEL LOAD AT EACH POINT Lbs (Kgs) TOTAL
APMR A1 A2 A3 A4 A5 A6 WEIGHT
174 200 129 142 645
51055G1 - -
[79] [91] [59] [64] [293]
155 176 186 187 704
51070G1 - -
[70] [80] [84] [85] [319]
197 207 244 249 897
51080G1 - -
[89] [94] [111] [113] [407]
203 226 311 307 1046
51090G1 - -
[92] [102] [141] [139] [474]
205 230 312 309 1056
51100G1 - -
[93] [104] [141] [140] [478]
275 293 305 303 1176
51120G1 - -
[125] [133] [139] [137] [534]
363 363 448 448 1622
52130G1 - -
[165] [165] [203] [203] [736]
363 363 448 448 1622
52150G1 - -
[165] [165] [203] [203] [736]
421 421 557 557 1956
52170G1 - -
[191] [191] [253] [253] [887]
451 451 565 565 2032
52180G1 - -
[205] [205] [256] [256] [922]
484 484 561 561 2090
52210G1 - -
[220] [220] [254] [254] [948]
537 537 615 599 2288
52240G1 - -
[244] [244] [279] [272] [1038]
484 473 913 854 2724
52270G1 - -
[220] [215] [414] [387] [1235]
490 478 915 856 2739
52300G1 - -
[222] [217] [415] [388] [1242]
598 580 824 774 2776
52340G1 - -
[271] [263] [374] [351] [1259]
517 418 676 632 594 554 3391
52380G1
[234] [190] [307] [287] [269] [251] [1538]
745 788 622 652 383 413 3603
52420G1
[338] [357] [282] [296] [174] [187] [1634]
653 727 708 752 474 521 3835
52500G1
[296] [330] [321] [341] [215] [236] [1739]
550 580 1261 1171 594 701 4857
52550G1
[249] [263] [572] [531] [269] [318] [2203]
Table 13

S.K.M Air Conditioning LLC


23
SKM Packaged Air Conditioners APMRG1 Series

Recommended Clearances
MODEL
A B C
APMR-
46 76
51055G1
[1168] 42 [1930]
SPACING FOR AIR FLOW
[1067]
51070G1
SPACING FOR AIR FLOW
51080G1 / 51090G1 / 44
51100G1 [1118]
SPACING FOR AIR FLOW
52 SPACING FOR SERVICE
51120G1
52 [1321] 88
[1321] 64 [2235]
52130G1 / 52150G1 SPACING FOR SERVICE
[1626]
52170G1 / 52180G1 / 74 SPACING FOR SERVICE

Table 14
52210G1 [1880]
82
52240G1
[2083] C
ALL DIMENSIONS ARE IN INCHES [MM]
B
A C 30
[762] DUCT
A C B
A 30
A B
A [762] DUCT
30
A
A [762] DUCT
A
A
A
DUCT 30
DUCT B A
B 30 [762]
[762] DUCT 30 A
DUCT B
B
APMR- 51055G130 DUCT APMR-
[762]
30 C
51055G1
DUCT [762]
30
B
[762]
B
[762] B
A C 30
[762] DUCT
A C B
A 30
A B
A [762] DUCT
30
A
A [762] DUCT
A
A
A
DUCT 30
DUCT B A
B 30 [762]
[762] DUCT 30 A
DUCT B
B 30 DUCT [762]
30
DUCT [762]
30
B
[762]
A B A C
APMR- 51070G1 - 51120G1
[762] APMR- 51070G1 - 51120G1
A A C

A A C
A A
[762]

[762]
30

30

A A
[762]

[762]
30

30

A A
[762]

[762]
30

30

DUCT 30
B
DUCT DUCT
B [762] 30
DUCT 30 DUCT DUCT [762]
B
B [762] 30
DUCT 30
B
DUCT DUCT
B [762]
[762] 30
[762]
APMR- 52130G1 - 52240G1 APMR- 52130G1 - 52240G1

SINGLE UNIT MULTIPLE UNIT

24
Recommended Clearances R 22
REFRIGERANT
A B C
MODEL APMR-
68 120
52270G1 / 52300G1
[1727] [3048]
76 82 136
52340G1
[1930] [2083] [3454]
SPACING FOR SERVICE SPACING FOR AIR FLOW
52380G1 / 52420G1

Table 15
82 148
[2083] 79 [3759]
52500G1
[2007]

ALL DIMENSIONS ARE IN INCHES [MM]

A A A C A
[762]

[762]
30

30

DUCT 30 DUCT DUCT


B
B [762] 30
APMR- 52270G1 - 52340G1 [762]
APMR- 52270G1 - 52340G1

A A A C A
[762]

[762]
30

30

DUCT 30 DUCT DUCT


B
B [762] 30
APMR- 52380G1 APMR- 52380G1 [762]

A A A C A
[762]

[762]
30

30

DUCT 30 DUCT DUCT


B
B [762] 30
[762]
APMR- 52420G1 & 52500G1 APMR- 52420G1 & 52500G1

SINGLE UNIT MULTIPLE UNIT

S.K.M Air Conditioning LLC


25
SKM Packaged Air Conditioners APMRG1 Series

Recommended Clearances

[1168]
46

SPACING FOR SERVICE

SPACING FOR AIR FLOW

84*
DUCT 84*
[2134] [2134]

SINGLE UNIT
[1168]
46

84*
DUCT DUCT
90 84*
[2134] [2286] [2134]

* SPACING FOR BOTH AIR FLOW & SERVICE


MULTIPLE UNIT

APMR- 52550G1

26
Installation and Commissioning R 22
REFRIGERANT
• Install the unit in such a location which is flat and strong enough to support its weight.
• Provide a trap of over 2" (50mm) in the drain piping for water seal.


INSTALLATION & COMMISSIONING
All field wiring must comply with applicable local and national codes.
Service spacing should be provided as shown in the figure. If any obstacles are around the unit, distributed air is short-circuited
so that the unit stops frequently and access to the unit is difficult for inspection and aftersales services.

No obstacle

CONTROL
SPACING FOR AIRFLOW
PANEL BOX

3000
POWER AIR OUT
SOURCE SPACING FOR SERVICE
CONTROL
CIRCUIT AIR IN

S.AIR
AIR IN
No obstacle

R.AIR

3000
AIR OUT
CONTROL CONTROL
AIR IN
AIR IN PANEL BOX CIRCUIT
AIR OUT

POWER
SOURCE

APMR-51055G1
APMR- 51055G1 - 51120G1
- 51120G1
AIR IN

S.AIR

S.AIR

R.AIR

No obstacle CONTROL CONTROL


AIR IN
PANEL BOX CIRCUIT
AIR OUT
3000

AIR OUT
AIR OUT
POWER
SOURCE
AIR IN

AIR IN
APMR- 52130G1 - 52240G1
APMR-52130G1 - 52240G1

S.AIR

S.AIR

R.AIR

AIR OUT

AIR IN
CONTROL
No obstacle PANEL BOX
3000

AIR OUT
AIR IN

APMR-52270G1 - 52500G1
AIR OUT

APMR- 52270G1 - 52500G1


AIR OUT

S.AIR

S.AIR

R.AIR

APMR-52550G1

APMR- 52550G1

S.K.M Air Conditioning LLC


27
SKM Packaged Air Conditioners APMRG1 Series

GUIDE SPECIFICATIONS
GENERAL
Packaged Air Conditioners shall be composed of REFRIGERANT PIPING
compressor(s), condenser & evaporator coils with fans, refrigerant The refrigerant circuit piping shall be fabricated from ACR grade
piping, electrical components & enclosing cabinet in one piece. copper piping, with 1 & 2 refrigeration circuits, each liquid line
These units shall be factory assembled, internally wired, fully shall include filter drier and thermostatic expansion valve.
refrigerant charged with R410A, tested under strict quality
standards & are suitable for outdoor installation on rooftop or Suction line shall be insulated with ½” (12mm) wall thickness
ground level with ducted system. enclosed cell pipe insulation with maximum K factor
0.28 Btu.in /ft2 .h.°F. (0.040 W/mK).
COMPRESSOR(S)
Compressor shall be hermetic scroll, refrigerant gas cooled
furnished with internal overload protection device, crankcase
heater, and shall be mounted on rubber isolators.
CASING
Casing shall be made of hot dip galvanized (zinc coated),
phosphatized steel sheets which are then electrostatically
polyester powder coated to provide an extremely tough, scratch
resistance & excellent anti-corrosive protection. Casing shall
CONDENSER COIL(S)
pass1000 hours in 5% salt spray testing at 95°F (35°C) & 95%
Condenser coils shall be air cooled with integral sub cooler,
relative humidity as per ASTM B117. Evaporator section shall
constructed of special inner grooved seamless copper tubes
be sealed with vinyl gaskets & completely insulated faced with
3/8” OD mechanically expanded into corrugated aluminum cross
black glass tissue (BGT) heavy density, fire retardant, permanent
fins with maximum 16 fpi (1.6mm) spacing. These coils shall be
odorless fiberglass insulation of minimum 1” (25 mm) thickness
tested against leakage by high air pressure air 715psig (4930kPa)
and 32 kg/m3 density having maximum k factor 0.23 Btu.in/ft2
under water, cleaned & dehydrated at the factory.
h°f. (0.033 W / m °k). Unit casing shall be provided with access
panels for easy service and maintenance of all unit parts.

CONDENSER FAN(S) & MOTOR(S)


Condenser Fans shall be direct driven propeller type discharging
air vertically upward, equipped with statically & dynamically
FILTER SECTION
Flat Filter Section incorporating 1” (25mm) thick is provided as
balanced aluminum alloy blades, inherent corrosion resistant
standard and 2” (50mm) thick filter having an average arrestance
shaft & PVC coated steel wire fan guard. Condenser fan
efficiency of 54% as per ASHRAE Standard 52.1 or equivalent
motor(s) shall be Totally Enclosed Air Over (TEAO), 6 pole with
can be provided as an option.
class-F insulation, minimum IP-54 protection & wired to unit
control panel.

CONTROL PANEL
The panel shall be factory wired and confirm to IP-54 requirements.
EVAPORATOR COIL
Control panel shall contain compressor and motor starting
Evaporator coil shall be constructed of Hi-X copper tubes 3/8”
contactors, electronic control board for unit operation, compressor
OD mechanically bonded to aluminum (copper) corrugated fins
anti-recycle time delay, control on/off switch, control circuit breaker
with maximum 14 fpi (1.8mm) spacing. Coil consists of headers of
and power & control terminal blocks. High and Low pressure
seamless copper tubing, thermostatic expansion valve(s) & multi-
switches should be provided for protection.
circuited distributor(s). These coils shall be tested against leakage
by high air pressure 450psig(3100kPa) under water, cleaned &
dehydrated at the factory. Coil shall conform to AHRI-410.

EVAPORATOR FAN & MOTOR


Fans of evaporator shall be forward curved, double inlet double
width (DIDW), centrifugal type, statically & dynamically balanced,
mounted on a single heavy duty shaft with permanently lubricated
bearings and belt driven by V belts with an adjustable variable
pitch motor pulley. Motor shall be Totally Enclosed Fan Cooled
(TEFC), 4 poles, class-F insulated, minimum IP55 protection &
wired to unit control panel.

28
R 22
NOTES REFRIGERANT

S.K.M Air Conditioning LLC


29
SKM Packaged Air Conditioners APMRG1 Series

NOTES

30
R 22
NOTES REFRIGERANT

S.K.M Air Conditioning LLC


31
SKM Packaged Air Conditioners
CONTACT
APMRG1 Series
US
HEAD OFFICE

P.O Box: 6004, Sharjah,


United Arab Emirates

Tel: +971 6 514 3333


Fax: +971 6 514 3300

Email: [email protected]
Email: [email protected]

Spare Parts Division


[email protected]

Service Center
[email protected]

For SKM Regional Offices & Distributors


visit: www.skmaircon.com

224/2022A
32 Supersedes # 224/2022
CIRTIFICATE OF ORIGIN
21/05/2024

SUBJECT : COUNTRY OF ORIGIN


PROJECT : JUDICIAL INSTITUTION BUILDING - MINISTRY OF JUSTICE
CONTRACTOR : M/S. Al AUSUS AL ARBAA GEN CONT .CO .L.L.C.

Dear Sir,

We would like to confirm the Country of Origin for the that following units below:
Item Description Qty Country Of Origin
APMR52130G1 1 UAE
APMR52170G1 1 UAE
APMR52170G1 1 UAE
APMR52210G1 1 UAE
APMR52210G1 2 UAE
APMR52210G1 2 UAE
APMR52150G1 1 UAE
APMR52180G1 1 UAE
RXVPG18 + DDPPG18 2 UAE

Please feel free to revert for any further clarifications.


Thank you,

For, SKM Air Conditioning LLC


DRAFT WARRANTY CERTIFICATE
Factory & Sales Head Office
P.O. Box 6004, Sharjah,
United Arab Emirates
S.K.M Air Conditioning LLC Tel: + 971 6 514 3333
Fax: + 971 6 514 3300
AIR-CONDITIONING Toll Free Number: 800 MYSKM (69756)
EQUIPMENT WARRANTY CERTIFICATE Email: [email protected]

CLIENT
PRODUCTS
WARRANTY CLAIM NUMBER
SKM JOB NUMBER
DELIVERY DATE

SKM (the Company) warrants that the equipment’s supplied under the above Job Number and as identified in the attached list, is free from defects in
material and workmanship, at the time of dispatch from our premises.
Should the equipment fail to meet this warranty within 12 (twelve) months from the date of startup/commissioning, or 18 (eighteen) months from the date
shipped by the company, whichever occurs first, and provided the original owner notifies the Company or its authorized representative within 30 days of
the discovery of the failure, the Company shall, at its option, replace or repair any defective part thereof.
2 years Extended warranty will be provided
GENERAL C ONDITIONS
This warranty is subject to the following terms and conditions:

1. This Warranty constitutes the owner’s sole remedy. It is given in lieu of all other warranties. There is no implied warranty of merchantability or
fitness for a particular purpose. In no event and under no circumstance shall the company be liable for incidental, indirect, special, contingent or
consequential damages of whatsoever nature and caused for whatsoever reason, whether the theory be breach of this or any other warranty,
negligence or strict liability in tort.

2. This warranty applies only to the original owner, and with respect to the original installation.

3. No changes in this warranty, or in the terms and conditions herein, shall be valid unless confirmed in writing and signed by an authorized officer of
the Company, and carrying the Company stamp.

4. This warranty does not include the cost of labor in repairing or removing a defective part, or in installing a replacement part. Refrigerant gas, fluids,
oils and expendable items such as filters, belts etc… are not covered by this warranty, howsoever lost or damaged.

5. The Company shall have no obligation under this warranty, unless the equipment was installed and was operated at its specified conditions and in
strict accordance with the Company's written recommendations as stipulated in the ‘Installation, Operation and Maintenance Manuals’.

6. The Company shall have no obligation under this warranty, if in the opinion of the Company, the equipment was subject to damage in transit,
deterioration or damage while stored by someone other than the Company, or on Site, or was improperly maintained, serviced or repaired by any
third party in such a way as to adversely affect its reliability or if the equipment was subjected to misuse, neglect, alterations, accidents, floods,
acts of God or if equipment was operated by a site generator with associated, external to the equipment, electrical wiring not in accordance with
local codes.

7. The Company shall have no obligation under this warranty, if the equipment serial number has been altered, defaced or removed.

8. This warranty applies only to equipment installed within the boundaries of the Company's operating territory.

Form Number: MFK/WRNTY/2017


9. The equipment or parts thereof, shall be returned in accordance with instructions received from the Company or its authorized representatives.
This warranty shall not include the cost of associated freight or delivery charges. Prior to the return of any equipment or part, due notification must
be given, in writing, to the installation contractor, the Company's authorized representative or direct to the Company.
10. For Chillers, The Company shall have no obligation under this warranty, if the Chiller startup was not executed by SKM or its authorized
representative, or if Water Quality reports or Chiller schematics are not available with the owner.
11. The Company does not warrant, in any way, the suitability or fitness, of the supplied equipment for any specific application or the performance of
the equipment to match specific conditions for a specific end-usage. Capacities as catalogued by the Company for its equipment are correct
subject to normal stated industry standards.
12. Warranty of compressor is applicable for one time replacement only, unless proven that it is due to a manufacturing defect.
13. Any replacement and/or repairs carried by the Company under this warranty shall not extend the original equipment warranty beyond the stated
period in this warranty, unless previously agreed as per Clause-3 above.
14. For additional consideration, if in any case the Company is providing an extended warranty(ies) on certain products or components thereof, then
the terms of the extended warranty(ies) will be shown on a separate extended warranty statement.

____________________ ________________________
PREVIOUS PROJECT APPROVAL
Trojan General Contracting L.L.C ADPorts Projects
Contract No./Name: 4201-232

Abu Dhabi Ports


Project

Contract No. 4201-232


PROJECT TITLE
Critical Warehousing Capacity Enhancement

Material Approval Request for VRF System (KLP-04&05 - HVAC)


Manufacturer & Supplier M/s. SKM Air Conditioning L.L.C

CONTRACTOR’S VERIFICATION STAMP DOCUMENT STATUS STAMP


We, Trojan General Contracting, verify that this contractor's document:

• Has been produced and checked in accordance with contractor's quality


assurance plan

• Is of a standard that will enable the employer to accept it in accordance


with the contract
SANGEETH KUMAR
• Complies with all requirements of the contract 14-06-2021 Code 2
____________________ ______________
Following deviations to contract are referenced for which a dispensation has
Abu Dhabi Ports Code
been accepted by the employer:
None Code 1: Work may proceed.

Other related letters/CTIs which document clarifications associated with this


document are listed below:
 Code 2:
Revise & Resubmit. Work may proceed subject to
incorporation of comments indicated.
None Code 3: Revise & Resubmit. Work may not proceed.

Consultant/Contractor’s Project Director: Code 4: Review not required. Work may proceed.

The statement "work may proceed" applies to the following work activities
associated with the matters contained within the contractor's document:

Any review, comment or acceptance by employer under this contract with


Engr. Awsam Matloob 09-06-2021 respect to any of contractor’s documents shall not in any way be, or deemed to
___________________ ___________________ ___________ be, an approval of any works or an acceptance that the contractor’s documents
Project Director Signature Date meet the requirements of the contract, as contractor has the sole responsibility
for performing the works in accordance with the requirements of this contract.

Document Number: 4201-232-V4-7610-05067 (NPC Ref: MTS-MEP-ME-HVAC-067-REV-01

Eng. Mohamed Eng. Sameh Eng.


001 09-Jun-2021 Issued for Approval Rafat Farahat Awsam
Rev Date Reason For Revision Prepared Checked Approved
Holders of registered copies receive revisions to this document, should they occur, with a request that the superseded copy be destroyed. Registration of copies
eases at taking over date. The revision number is included at the end of the document number, which is noted in the right of the bottom of each page. When
amendments occur, the whole document is re-issued with the revision number updated accordingly.
(1) Revisions are shown in italics. Deletions are hidden. Earlier additions revert to normal text in subsequent amendments
(2) The QA Manager reviews and the project Manager approves amendments by signature on the cover sheet to the document
(3) The document controller maintains a Register of the holders of this document
(4) Amendments to the document are distributed according to (1) above and this I reflected in the register
The document controller keeps the original of the latest version of this document

Ref. No.: 4201-232-V4-7610-05067 Rev.001 UNCONTROLLED, IF PRINTED


BECHTEL/PETROFAC
Al Taweelah Alumina
25875

PO/Contract Number: 25875-070-HC2-G00Z-00026

Supplier/Contractor Name: Al Nasr Contracting Co. LLC

Document Title: Material Submittal of HVAC - VRF


(Variable Refrigerent Flow) System M/s. CIVILCO
Engineering Services Division

Supplier/Contractor Doc Number: Rev:


BPJV-ANC-C063-MA-043 002

Project Document Number: Rev:


25875-070-V26-G00Z-00059 002

Document Review Stamp

It is noted that the Condensing Coil Aluminium fins are coated with anti-corrosion media that
is not fully resistant to Caustic Soda Vapour, however given that concentration of the vapour
is heavily diluted in ambient air, and that the Split System/VRF units have industry norm
construction, the units are approved. However, the Contractor is to provide periodic
maintenance narratives that guides the Facilities Management team as to the frequency &
specifics for mimising fin wear.

PROJECT Al Taweelah Alumina

SUPPLIER/CONTRACTOR DOCUMENT REVIEW

Permission to proceed does not constitute acceptance or approval of design detail, calculations,
analyses, test methods, or materials developed or selected by SUPPLIER/Contractor, and does
not relieve the SUPPLIER/Contractor from full compliance with contractual obligations.

1 WORK MAY PROCEED Document Status: 1C


WORK MAY PROCEED – EDITORIAL COMMENTS NEED ONLY BE
1C INCORPORATED IF REVISED FOR OTHER PURPOSES

REVISE & RESUBMIT – WORK MAY PROCEED SUBJECT TO


2 INCORPORATION OF CHANGES INDICATED

REVISE & RESUBMIT – WORK MAY PROCEED SUBJECT TO


2CR INCORPORATION OF CHANGES INDICATED – PRIORITY RETURN

3 REJECTED. REVISE & RESUBMIT – WORK MAY NOT PROCEED

4 REVIEW NOT REQUIRED. WORK MAY PROCEED

RESPONSIBLE ENGINEER: Obikwu_Fidelis DATE: 22-02-2018

DISCIPLINE: EA - Architectural DDR: NO: DDR200

PO / CONTRACT NO:

25875-070-HC2-G00Z-00026

PROJECT DOCUMENT NO: Submittal:

25875-070-V26-G00Z-00059 002

Equipment Number (if applicable):

MAC 059
PROJECT REFERENCE LIST
SKM
Air Conditioning Equipment
PRESTIGIOUS PROJECTS BROCHURE

facebook.com/skmuae www.skm.ae youtube.com/marketingskm

Sharjah Economic Excellence


Award winner
SKM units have been installed in Palaces, Mosques, Hospitals, Airports,
Ministries, Universities, Schools & other buildings in the Middle East and
beyond.

2
Landmark
Projects
Sweet Homes Ajman, UAE Al Noor Mosque Sharjah, UAE

Jumeirah Beach Hotel, Kuwait KAUST Housing Project, KSA

Al Murooj Rotana Dubai, UAE IKEA stores (Various Locations in UAE)

Abu Dhabi Airport, UAE Cayan Tower Dubai, UAE


Mzizima Towers, Dar es Salam, Tanzania AKOYA Dubai, UAE

Mecca Mall, Jordan Farwaniya Hospital, Kuwait Wave Muscat , Oman National Theatre of Bahrain 30

26 27
Jomo Kenyatta Internation Airport, Nairobi Giza North Power Station, Egypt

Al Mashaaer Al Mugaddasah Metro, KSA Surma Tower, Bangla Desh

New Cairo Exhibition Centre, Egypt King Abdullah Financial District, KSA

Opus Tower Dubai, UAE Access Tower, Sri Lanka

World Trade Center, Bahrain

Mamsha Al Saadiyat Abu Dhabi, UAE Bahria Icon Tower, Pakistan SWCC Jubail Housing, KSA Jumeirah Beach Hotel Dubai, UAE

28 29
END.

You might also like