0% found this document useful (0 votes)
50 views2 pages

Catalog Bien Tan Inovance MD310

The MD310 AC Drive is an open-loop general purpose drive with a wide operating voltage range of 323 to 480 Vac and power capacities from 0.4 kW to 18.5 kW. It features automatic torque boost, slip compensation, and supports communication via Modbus or optional CANlink. The drive is designed for high ambient temperatures and can control multiple motors simultaneously in different modes.

Uploaded by

phvandong_bk
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views2 pages

Catalog Bien Tan Inovance MD310

The MD310 AC Drive is an open-loop general purpose drive with a wide operating voltage range of 323 to 480 Vac and power capacities from 0.4 kW to 18.5 kW. It features automatic torque boost, slip compensation, and supports communication via Modbus or optional CANlink. The drive is designed for high ambient temperatures and can control multiple motors simultaneously in different modes.

Uploaded by

phvandong_bk
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

MD310 AC Drive

Open Loop General Purpose & Economic

Features & Functions


Wide operating voltage
■ Open-loop V/F & SVC control Three-phase 323 to 480 Vac
0.4 kW to 18.5 kW
■ Staring torque
• 150% at 0.5 Hz (SVC)
• 100% at 1.0 Hz (V/F)
■ Modbus or CANlink*1 comms Onboard Modbus RTU
(optional CANlink*1)
■ Automatic torque boost
■ Slip compensation
■ Simplified parameter for easy set-up
Operation in high
■ 4 independent S-Ramps ambient temperature
■ Flexible programmable I/O 45℃avg
connection
■ Variable DC-injection braking
■ Comprehensive trip diagnostics
■ Output frequency 500 Hz
■ In-built dynamic braking unit

Note
*1 CANlink is Inovance proprietary serial comms.
Switchover among multiple motors
Swing Frequency

Output frequency
Swing amplitude
Aw=Fset*FB-01
+Aw
Swing freq. upper limit

Center freq. Fset


-Aw
Swing freq. lower limit
Jump frequency
=Aw*FB-02

Time
Acceleration Swing Rise Deceleration
cycle time Control multiple motors Control up to 2 motors in
simultaneously in V/F mode different time divisions in
RUN command SVC mode (multiple motor
parameter groups)
General Specifications

Voltage Class Three-phase 380Vac


Drive model:
0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5
MD310TxxxB-INT

Frame Size 1 Size 2 Size 3 Size 4

Height [H]: 128 mm [H1]: 209 mm [H1]: 260 mm [H1]: 298 mm


Dimension Width [W]: 108 mm [W]: 130 mm [W]: 140 mm [W]: 180 mm
Depth [D]: 158 mm [D]: 164 mm [D]: 171 mm [D]: 176 mm

Rated input voltage Three-phase 380 to 480 Vac, -15% to +10% (323 to 528 Vac)
Drive Input

Rated input current [A] 1.9 3.4 5 5.8 10.5 14.6 20.5 26 35 38.5

Power capacity [kVA] 1 1.5 3 4 5.9 8.9 11 17 21 24

Rated input frequency 50/60 Hz, ±5% (47.5 to 63 Hz)

Applicable motor [kW] 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5

Output current [A] 1.5 2.1 3.8 5.1 9 13 17 25 32 37


Drive Output

*1

Overload capacity 150% for 60 Sec & 180% for 2 Sec

Max. output voltage 380 to 440 Vac (Proportional to input voltage)

Max. output frequency 500 Hz

Recommended
150 150 150 250 300 400 500 800 1,000 1,300
Resistor

power [W]
Braking

Recommended
resistance [Ω] ≥300 ≥300 ≥220 ≥200 ≥130 ≥90 ≥65 ≥43 ≥32 ≥25

Enclosure IP 20

*1 Carrier switching frequency 6 kHz at rated output current.

General Connection Diagram Dimensions


2
W
1
External braking resistor (prepared by user) A

BR
L1 R U

IM
External Line
Mains L2 RFI Filter Reactor S V
(option)
Supply
Dimensions of
(option) FED
FED

LO
/RE
/RE
W
W

L3
CA
L

T W
RU
N/E
RR

drives from
B

MD310
H

0.4 to 2.2 kW
Supply Ground
+24Vd c
RJ45 Hot pluggable
remote keypad D
RUN rorward [ F4-00 = 1 ] DI1 (optional)

Forward Jog [ F4-01 = 4 ] DI2

W
Fault reset [ F4-02 = 9 ] DI3 (0 to10Vdc) 0 100%

AO A

Multi-reference 1 [ F4-03 = 12 ] DI4 GND

FM
Multi-reference 2 [ F4-04 = 13 ] DI5
Pulse output: 0 to 50 kHz
Open- collector output:
10 to 24 Vdc / 0 to 50 mA
Dimensions of
COM
COM drives from
FED
FED /REW
/RE

DO1
LO

10Vdc
CA W
RU L
N/E
RR

VR [0 to10Vdc] or
AI1
Voltage or Current input mode Open-collector output: 3.7 to 18.5 kW B H1
1 to 5kΩ selectable via DIP switch 10 to 24Vdc / 0 to 50mA H
[0~20mA] (default voltage input mode)
AI2
CME
GND
T/C
RS485+ 485+
T/B Relay output:
250 Vac 10 mA to 3A
RS485- 485- 30 Vdc 10 mA to 1A
T/A
D
GND

Hong Kong SAR India Germany-Stuttgart France-Bordeaux


(export office) Head Office Chennai Tel: +49 (0) 7144 8990 Tel: +33 (0) 5594 01050
Forward, Always Progressing Tel: +852 2751 6080 Tel: +91 (0) 44 4380 0201
[email protected] [email protected]
[email protected] Ahmedabad Tel: +91 (0) 79 4003 4274
Mumbai Tel: +91 (0) 22 4971 5883
Delhi Tel: (to be allotted) Italy-Milano Turkey-Istanbul
South Korea-Seoul
Sales Network in Kolkata, Bengaluru, Tel: +39 (0) 2268 22318 Tel: +90 (0) 21 6706 1789
Tel: +82 (0) 10 7428 5732
Coimbatore, Hyderabad, Pune [email protected] [email protected]
[email protected]
[email protected]

Copyright Inovance Technology Co., Ltd. All rights reserved. Data code: L6210105 V2.1