The document provides technical specifications for the 3WA1350-5AB02-5BQ4 circuit breaker, including its voltage type, number of poles, rated operating voltage, and breaking capacity. It details the design features, protection mechanisms, and auxiliary components associated with the circuit breaker. Additionally, a parts list with order numbers for various accessories related to the circuit breaker is included.

Uploaded by

gustavo rittter
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views3 pages

3wa 2024 11 01

The document provides technical specifications for the 3WA1350-5AB02-5BQ4 circuit breaker, including its voltage type, number of poles, rated operating voltage, and breaking capacity. It details the design features, protection mechanisms, and auxiliary components associated with the circuit breaker. Additionally, a parts list with order numbers for various accessories related to the circuit breaker is included.

Uploaded by

gustavo rittter
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

01.11.

2024 19:39

3WA circuit breaker


3WA1350-5AB02-5BQ4

Technical details
Voltage type AC

Number of poles 3

Position of N-conductor no internal N-conductor

Breaker type Circuit breaker

Rated operating voltage Ue at AC <=690 V

Continuous current In,max 5000 A

maximum short-circuit current breaking 100 kA


capacity (Icu) up to 500 V / rated value

maximum short-circuit current breaking 85 kA


capacity (Icu) up to 690 V / rated value

Breaking capacity class of the circuit H


breaker / non-automatic circuit breaker

Size of the circuit-breaker 3

Type Fixed-mounted circuit breaker

position signal switch module no

Main current connection Rear horizontal main connection

Protection Electronic trip unit LSI

Communication ability no

Design of the overcurrent release ETU300

Tensioning the spring mechanism with motorized operating mechanism

Supply voltage of the motor drive 24-30 VDC

Number of auxiliary switches ON / OFF 4 NC + 4 NO

Design of the closing coil CC 100% OP for continuous duty


Supply voltage of the closing coil 24-30 V DC

Remote reset magnet for trip signaling No

Type of the 1st shunt trip ST 100% OP for continuous duty

Supply voltage of the 1st shunt trip 208-240 V AC / 220-250 V DC

Design of the 2nd auxiliary release UVR undelayed

Supply voltage of the 2nd auxiliary release 208-240 V AC / 220-250 V DC

Parts list order numbers

3WA9111-0AG01
Accessory Circuit breaker 3WA, Auxiliary switch block (AUX) 2NO+2NC
2 pcs.

3WA9111-0AH01
Accessory Circuit breaker 3WA, Ready-to-close signaling switch S20
1 pc.

3WA9111-0EB50
Accessory circuit breaker 3WA, Option Plug LSI 5000 A Basic protective function LT,
ST and INST, Rated current 5000 A
1 pc.

3WA9111-0EE32
Accessory circuit breaker 3WA, Electronic Trip Unit ETU300 LSI / LSIG
1 pc.

3WA9111-0AH02
Accessory Circuit breaker 3WA, 1st Trip alarm switch 1 CO contact (S24)
1 pc.

3WA9111-0AB01
Accessory 3WA/3WL Base part for secondary disconnect terminals
4 pcs.

3WA9111-0AB12
Accessory 3WA/3WL Dummy block for secondary disconnect
1 pc.

3WA9111-0AB07
Accessory 3WA/3WL Coding kit for secondary disconnect terminals
1 pc.

3WA9111-0AB04
Accessory 3WA/3WL Secondary disconnect terminals Push-in connection terminals
4 pcs.

3WA9111-0AF02
Accessory 3WA/3WL Charging Motor (M) 24-30 V DC
1 pc.
3WA9111-0AH06
Accessory Circuit breaker 3WA, Springs charged indicator 1 NO contact (S21)
1 pc.

3WA9111-0AD02
Accessory 3WA/3WL Closing coil (CC) / Shunt trip (ST), 100% OP 24-30 V DC for
continuous duty
1 pc.

3WA9111-0AE06
Accessory 3WA/3WL Undervoltage release (UVR) Instantaneous (0,08 s) and
short-delay (0,2 s), 208-240 V AC / 220-250 V DC,
1 pc.

3WA9111-0AD06
Accessory 3WA/3WL Closing coil (CC) / Shunt trip (ST), 100% OP 208-240 V AC /
220-250 V DC for continuous duty
1 pc.