Copper Tubes of type K are thick walled, much thicker than type L and M and are used for domestic water-, service and distribution-, fire protection-, solar-, fuel and oil-, HVAC-, compressed air-, natural gas-, oxygen-, LPG gas-, snow melting-, steamand vacuum-systems.

Uploaded by

Jacques Swart
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views4 pages

Copper Tubes - ASTM B88

Copper Tubes of type K are thick walled, much thicker than type L and M and are used for domestic water-, service and distribution-, fire protection-, solar-, fuel and oil-, HVAC-, compressed air-, natural gas-, oxygen-, LPG gas-, snow melting-, steamand vacuum-systems.

Uploaded by

Jacques Swart
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Copper Tubes - ASTM B88

Page 1 of 4

Ads by Google

Copper Tube Fittings

Steel Tube Bending

Copper Pipe Bender

Air Fittings

Fitting Dimensions

Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Search

The Engineering ToolBox

Web

Copper Tubes - ASTM B88


Copper Water and Gas Tube according ASTM B 88 - imperial units
Sponsored Links

Tube/Pipe Bender Tooling Full Service Bender Tooling Mfg Tube Bending, End-Forming Etc.
www.EatonLeonardTooling.com

Piping Analysis Software Pipe Flow Network Analysis & System Modeling. Download A Working Demo!
www.AFT.com/WaterHammer

China Seamless steel pipe Quality seamless steel pipe here , All specifications you need.Order!
www.stwfgg.com

Dimensions of copper tubes according ASTM B88 STANDARD SPECIFICATION FOR SEAMLESS COPPER WATER TUBE can be found in the table below:

Type K Nominal Size (inches) 1/4 3/8 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 1/2 3 3 1/2 4 5 6 Actual Outside Diameter (inches) 3/8 1/2 5/8 3/4 7/8 1 1/8 1 3/8 1 5/8 2 1/8 2 5/8 3 1/8 3 5/8 4 1/8 5 1/8 6 1/8 0.375 0.500 0.625 0.750 0.875 1.125 1.375 1.625 2.125 2.625 3.125 3.625 4.125 5.125 6.125 Tolerance on Outside Diameter (inches) Annealed1) Drawn2) 0.002 0.0025 0.0025 0.0025 0.003 0.0035 0.004 0.0045 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.001 0.001 0.001 0.001 0.001 0.0015 0.0015 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 Wall Thickness (inches) Nominal 0.035 0.049 0.049 0.049 0.065 0.065 0.065 0.072 0.083 0.095 0.109 0.120 0.134 0.160 0.192 Tolerance 0.0035 0.005 0.005 0.005 0.006 0.006 0.006 0.007 0.008 0.010 0.011 0.012 0.013 0.016 0.019 0.133 0.269 0.344 0.418 0.641 0.837 1.04 1.36 2.06 2.92 4.00 5.12 6.51 9.67 13.87 Weight (lb/ft)

Copper tubes of type K are thick walled, much thicker than type L and M and are used for domestic water-, service and distribution-, fire protection-, solar-, fuel and oil-, HVAC-, compressed air-, natural gas-, oxygen-, LPG gas-, snow melting-, steam- and vacuum-systems. Copper tubes of type K can be used sweat, flared and compression fittings. Available in hard and soft types.

Type L Nominal Size (inches) 1/4 3/8 1/2 5/8 3/4 1 1 1/4 1 1/2 Actual Outside Diameter (inches) 3/8 1/2 5/8 3/4 7/8 1 1/8 1 3/8 1 5/8 0.375 0.500 0.625 0.750 0.875 1.125 1.375 1.625 Tolerance on Outside Diameter (inches) Annealed1) Drawn2) 0.002 0.0025 0.0025 0.0025 0.003 0.0035 0.004 0.0045 0.001 0.001 0.001 0.001 0.001 0.0015 0.0015 0.002 Wall Thickness (inches) Nominal 0.030 0.035 0.040 0.042 0.045 0.050 0.055 0.060 Tolerance 0.003 0.004 0.004 0.004 0.004 0.005 0.006 0.006 0.126 0.198 0.285 0.362 0.455 0.655 0.884 1.14 Weight (lb/ft)

http://www.engineeringtoolbox.com/astm-copper-tubes-d_779.html

2009/10/26

Copper Tubes - ASTM B88

Page 2 of 4

4 5 6

4 1/8 5 1/8 6 1/8

4.125 5.125 6.125

0.005 0.005 0.005

0.002 0.002 0.002

0.114 0.125 0.140

0.011 0.012 0.014

5.38 7.61 10.20

Standard copper tubes of type L are used for interior above ground plumbing - domestic water-, service and distribution-, fire protection-, solar-, fuel and oil-, HVAC-, compressed air-, natural gas-, LPG gas-, snow melting- and vacuum-systems. Copper tubes of type L can be used with sweat, compression and flare fittings. Only seat and flare fittings are legal for gas lines. Available in hard and soft types.

Type M Nominal Size (inches) 1/4 3/8 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 1/2 3 3 1/2 4 5 6 Actual Outside Diameter (inches) 3/8 1/2 5/8 3/4 7/8 1 1/8 1 3/8 1 5/8 2 1/8 2 5/8 3 1/8 3 5/8 4 1/8 5 1/8 6 1/8 0.375 0.500 0.625 0.750 0.875 1.125 1.375 1.625 2.125 2.625 3.125 3.625 4.125 5.125 6.125 Tolerance on Outside Diameter (inches) Annealed1) Drawn2) 0.002 0.0025 0.0025 0.0025 0.003 0.0035 0.004 0.0045 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.001 0.001 0.001 0.001 0.001 0.0015 0.0015 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.032 0.035 0.042 0.049 0.058 0.065 0.072 0.083 0.095 0.109 0.122 0.003 0.004 0.004 0.005 0.006 0.006 0.007 0.008 0.010 0.011 0.012 0.025 0.028 0.002 0.003 Wall Thickness (inches) Nominal Tolerance 0.106 0.144 0.203 0.263 0.328 0.464 0.681 0.94 1.46 2.03 2.68 3.58 4.66 6.66 8.91 Weight (lb/ft)

Copper tubes of type M are used for interior domestic water-, service and distribution-, fire protection-, solar-, fuel and oil-, HVAC-, snow melting- and vacuum-systems. Wall thickness less than type K and L. Copper tubes type M are normally used with flare fittings. Available in soft and hard types.

1 in (inch) = 25.4 mm

1)

Annealed tube is suitable for use with flared or compression fittings, and with solder-type fittings, provided rounding and sizing of the tube ends is performed where needed.
2)

Drawn temper tube is suitable for use with solder-type fittings. Types A and B tube, in the drawn temper, are suitable for use with certain types and sizes of compression fittings. The standard length for drawn tubes are 20 ft (6.096 m). The B88 specification covers seamless copper water tube suitable for general plumbing, similar applications for the conveyance of fluids, and commonly used with solder, flared, or compression-type fittings. The type of copper water tube suitable for any particular application is determined by the internal or external fluid pressure, by the installation and service conditions, and by local requirements. Means of joining or bending are also factors that affect the selection of the type of tube to be used. This specification is the imperial companion of Specification B 88M. Sponsored Links

F.R.W Carobronze Tube Bending and Assembly specialiste bronze et alliages French Fluid Handling Products,CNC Bronze and alloys specialist Bending Metal,Rubber,Plastic Hose www.frwcarobronze.fr forming
www.tubemasters.co.uk

High Speed Over Copper Copper Fibre Channel Transceivers Ethernet SFP, XFP, X2, CX4, Cages
www.MethodeDataMate.com

Related Topics

Dimensions Sizes and dimensions of pipes and tubes, and their fittings - inside and outside diameter, weight and more

http://www.engineeringtoolbox.com/astm-copper-tubes-d_779.html

2009/10/26

Copper Tubes - ASTM B88

Page 3 of 4

Copper Tubes to BS (British Standard) 2871 - Dimensions and Working Pressures Metric Sizes of copper tubes to BS (British Standard) 2871:1972 Copper Tubes - Dimensions and Working Pressures Dimensions and working pressures of copper tubes according BS (British Standard) 2871:1972 Difference between Pipes and Tubes Pipes and tubes are not the same Heat Carrying Capacity of Copper Tube Hot water heat carrying capacity of copper tube type L Copper Tubes - ASTM B88M Copper Water and Gas Tube according ASTM B 88M - metric units Comparing Friction Loss in Steel, Copper and Plastic Pipes Water flow and friction head loss (ft/100 ft) - steel, copper and PVC plastic pipes Hot Bending - Copper and Copper Alloy Pipe Temperature range for bending copper pipe and tube Pressure Loss of Water Due to Friction in Copper Tubes Pressure Loss (psi/ft) of Water Due to Friction in Copper Tubes Types K, L and M Copper Tube - ASTM B88 Copper Pipe - Water Velocity Limits The water velocities in copper pipes should not exceed certain limits to avoid erosion Copper Tubes DWV - Drain, Waste and Vent Dimensions of copper tube ASTM 306 DWV - Drain Waste and Vent Sponsored Links

Sanxin Steel Tube High quality steel tubes from China, post your offer now!
www.cnsteeltubes.com

Pipe polishing machine Effective solution for the removal rust and paint from a tube end
www.wortelboer.ws

Aluminium Bronze High Integrity Nickel-Ali Bronze Engineered to ASTM, BS, EN, AMS
www.copperalloys.net

ToolBox Short List


Difficult to find your favorite ToolBox page? Add links to your favorite pages in your own personal Short List! Add this Page! Delete the ShortList!

Engineering ToolBox - SketchUp Edition - Online 3D modeling!

Engineering ToolBox - SketchUp Edition - enabled for use with the amazing, fun and free Google SketchUp.

Search the ToolBox

Search Web The Engineering ToolBox

Translate the ToolBox


Arabic - Chinese (Simplified) - Chinese (Traditional) - Dutch - French - German - Italian - Japanese - Korean Portuguese - Russian - Spanish

About the ToolBox


We appreciate any comments and tips on how to make The Engineering ToolBox a better information source. Please contact us by email

[email protected]

if You find any faults, inaccuracies, or otherwise unacceptable information. The content in The Engineering ToolBox is copyrighted but can be used with NO WARRANTY or LIABILITY. Important

http://www.engineeringtoolbox.com/astm-copper-tubes-d_779.html

2009/10/26

Copper Tubes - ASTM B88

Page 4 of 4

The Engineering ToolBox 2005 9 10 13

http://www.engineeringtoolbox.com/astm-copper-tubes-d_779.html

2009/10/26