0% found this document useful (0 votes)
11 views4 pages

LM 79 Sub 118 t8 Led (Eco) Glaze + Sle TL Ds 20 P Al Ext

The document is a test report for the SUB 118 T8 LED (ECO) GLAZE + SLE TL DS 20 P lamp conducted by Surya Technology & Innovation Centre on June 4, 2024. The report confirms that the sample passed electrical and photometric tests according to the LM-79-08 standard, with a total measured lumen of 2022.41 lm and efficacy of 101.68 lm/W. The report includes details on testing conditions, equipment used, and results, along with disclaimers regarding the reproduction and applicability of the results to the tested sample only.

Uploaded by

inq1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views4 pages

LM 79 Sub 118 t8 Led (Eco) Glaze + Sle TL Ds 20 P Al Ext

The document is a test report for the SUB 118 T8 LED (ECO) GLAZE + SLE TL DS 20 P lamp conducted by Surya Technology & Innovation Centre on June 4, 2024. The report confirms that the sample passed electrical and photometric tests according to the LM-79-08 standard, with a total measured lumen of 2022.41 lm and efficacy of 101.68 lm/W. The report includes details on testing conditions, equipment used, and results, along with disclaimers regarding the reproduction and applicability of the results to the tested sample only.

Uploaded by

inq1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

SURYA TECHNOLOGY & INNOVATION CENTRE

SURYA ROSHNI LTD.


Lighting Division
D-63, Hosiery Complex Phase-II
Noida (U.P.), 201305
Contact: +91 (120) 4825400
Email: [email protected]
Web: http://www.surya.co.in

Test Report for LED Lamp/Luminaire


Report Number STIC-LM79-2024-LT003
Date 04-06-2024
Testing Agency Surya Technology & Innovation Centre
Customer Details
Surya Roshni Limited
LBG Division
Padma Tower -1
Rajendra Palace
New Delhi 110008
SUB 118 T8 LED (ECO) GLAZE + SLE TL DS 20 P
Product Catalogue Reference
AL EXT
Brand SURYA
Sample ID: 2404F03
SUB 118 T8 LED (ECO) GLAZE + SLE TL DS 20 P
Test Sample Description
AL EXT
Equipment used Validity of calibration
LMT Mirror Goniophotometer GO-DS 2000 Calibrated by NPL
Lab ID. STIC/PH/GO-DS /00,01,02 Valid till 22/05/2025
Spectrophotometer HAAS-1200_VIR_300 Calibrated by NPL
Lab ID. STIC/PH/01-B,C,D Valid till 22/05/2025
Calibrated by NPL
Standard light source Model: D204
Valid till 18/01/2025
DIGITAL POWER METER EVERFINE & PF9811 Calibrated by PV Calibration Lab Pvt. Ltd.Valid till
Lab ID .STIC/PH/04-B 16/05/2025
Programmable AC Calibrated by PV Calibration Lab Pvt. Ltd.Valid till
Source Lab ID. STIC/PH/04-E 16/05/2025
Test procedure applicable MS-2L-015
Test Details: Document References/Standard:
 Light Intensity Distribution LM-79-08/ IS 16106:2012
 Luminous Flux Measurement
 Electrical Parameters Measurement
Disclaimer:
This report shall not be reproduced, except in full.
The results of test in this report apply only to sample item/ product tested.
No sampling was conducted by this laboratory for the test item/product mentioned overleaf.

SURYA TECHNOLOGY & INNOVATION CENTRE


Prepared By Approved By
Signature
Designation Engineer (R&D) Sr. Manager (P L)
SURYA TECHNOLOGY & INNOVATION CENTRE
SURYA ROSHNI LTD.
Lighting Division
D-63, Hosiery Complex Phase-II
Noida (U.P.), 201305
Contact: +91 (120) 4825400
Email: [email protected]
Web: http://www.surya.co.in

Electrical & Photometric Test Report


Sample ID 2404F03
Report Number STIC-LM79-2024-LT003
SUB 118 T8 LED (ECO) GLAZE + SLE TL DS 20 P
Catalogue Reference
AL EXT
Date of Testing 04-06-2024
Receipt Date 04-06-2024
Condition of sample Good
Orientation of Lamp/Luminaire Downward, no tilt
Photometric Distance 19.083 m

Test Conditions:
Standard applicable LM-79-08/ IS 16106:2012
Ambient Temperature 25.4º C
Relative Humidity 51.1 %
Test voltage 240Vac
Frequency 50Hz
Stabilization Time 60 min
Total operating time 90 min

Measured Electrical Parameters:


Supply Voltage 239.90 V
Input Current 0.087 A
Total Power 19.89 W
Power Factor 0.976

Photometric Measurement Data:


Total Measured Lumen 2022.41 lm
Efficacy 101.68 lm/W
Light Intensity Distribution Diagram Attached (Refer to page no. 3)
Spectrum report Attached (Refer to page no. 4)

SURYA TECHNOLOGY & INNOVATION CENTRE


Prepared By Approved By
Signature
Designation Engineer (R&D) Sr. Manager (P L)
SURYA TECHNOLOGY & INNOVATION CENTRE
SURYA ROSHNI LTD.
Lighting Division
D-63, Hosiery Complex Phase-II
Noida (U.P.), 201305
Contact: +91 (120) 4825400
Email: [email protected]
Web: http://www.surya.co.in

Light Intensity Distribution Diagram-

SUB 118 T8 LED (ECO) GLAZE + SLE TL


Catalogue Reference Sample ID 2404F03
DS 20 P AL EXT

SURYA TECHNOLOGY & INNOVATION CENTRE


Prepared By Approved By
Signature
Designation Engineer (R&D) Sr. Manager (P L)
SURYA TECHNOLOGY & INNOVATION CENTRE
SURYA ROSHNI LTD.
Lighting Division
D-63, Hosiery Complex Phase-II
Noida (U.P.), 201305
Contact: +91 (120) 4825400
Email: [email protected]
Web: http://www.surya.co.in
Spectrum Report –

Summary of Test Results


Test Parameter Standard Sample ID Result
Electrical & Photometry LM-79-08 2404F03 Pass

---------------------------End of Test Report---------------------------

SURYA TECHNOLOGY & INNOVATION CENTRE


Prepared By Approved By
Signature
Designation Engineer (R&D) Sr. Manager (P L)