The LT-TD system by EJOT revolutionizes the visible fastening of rainscreen facade cladding by introducing a 3.0 mm air gap for thermal decoupling, ensuring durability and aesthetic appeal. The system features various components such as centering grommets and stop collars that enhance installation accuracy and performance. Additionally, it offers a selection of screws tailored for different substructures and applications, promoting reliable assembly and ventilation.

Uploaded by

Raman Hammam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
75 views8 pages

EJOT Bro LT TD System 2025 EN

The LT-TD system by EJOT revolutionizes the visible fastening of rainscreen facade cladding by introducing a 3.0 mm air gap for thermal decoupling, ensuring durability and aesthetic appeal. The system features various components such as centering grommets and stop collars that enhance installation accuracy and performance. Additionally, it offers a selection of screws tailored for different substructures and applications, promoting reliable assembly and ventilation.

Uploaded by

Raman Hammam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Applications | Products | Special

LT-TD system
A revolution in the visible fastening of
rainscreen facade cladding

Bringing it together.
Fastening elements for facade claddings

LT-TD system
With the LT-TD system, EJOT has revolutionised the This additional rear ventilation within the rainscreen
visible fastening of rainscreen facade cladding: facade interrupts the heat flow from the inside of the
TD (thermal distance) means thermal decoupling by building to the panel surface and ensures that the
creating a 3.0 millimetre air gap between the facade facade dries evenly. The result is a durable, attractive
cladding and the substructure. facade without marking of the substructure.

Hexalobular drive TX25

Very flat screw head


(2 mm) for aesthetic
facade design
Head diameter (16 mm)
to cover large
pre-drill diameters

Shaft diameter (5 mm)


guarantees a relative displace-
ment (dilation) of 3 mm in all
directions at sliding points

Stop collar controls the exact setting


depth for a defined clamping range,
ensures vertical alignment and opti-
mum sliding points and increases the
contact surface of the TD grommets
between the facade panel and
substructure
Thread-free area
prevents destruction of
the female thread in the
substructure

Type JT4 with drill point


made of A2 stainless steel
for aluminium substructures

Type JT3 with hardened steel


drill point for steel or aluminium
substructures

2
Fastening elements for facade claddings

Detail view of fixed point for LT-TD system Detail view of sliding point for LT-TD system

LT-TD centring grommets


to form fixed points
Collets enclose the fasten-
er shank and ensure a tight
fit of the cladding

LT-TD centring grommets


to form sliding points

Centring ring positions screws


exactly in the centre of the
panel drill hole (11 mm)
Thin grommet edge (0.3 mm)
protects panel surface from
scratches

No impairment of dilatation in
all directions by 3 mm due to
Snap-on feet ensure a secure hold in minimal material retention in
the panel, provide a contact surface the panel hole
for the panel and create a 3 mm air
gap between the cladding and the
substructure

LT/STS Tool plastic

3
Fastening elements for facade claddings

The operating principle – the details make the difference

Standard system

Thermal coupling Angled screw connection Ventilation grille narrow point

Direct contact of the support profile A non-perpendicular screw con- The corner areas of the facade
with the facade cladding leads to nection can have a negative effect cladding are particularly sensitive.
weather-related markings of the on the sliding point and cause the The attachment points of ventilation
profile positions on the surface of facade cladding to break. grilles and end profiles can generate
the facade cladding. stresses and cause the facade
cladding to break.

LT-TD system

Thermal decoupling Perpendicular screw Space for ventilation grille


connection
The support profile has a 3 mm The attachment points of ventilation
gap to the facade cladding and grilles and end profiles have no con-
The perpendicular alignment of
is therefore thermally decoupled. tact with the facade cladding due to
the screw guarantees an optimum
The surface of the façade cladding the second rear ventilation level.
sliding point with a relative dis-
remains visually appealing in the
placement (dilation) of 3 mm in all
long term.
directions.

Perpendicular orientation with guarantee:


The stop collar

To ensure that screws can be screwed into components, their threads


naturally have a slope from the tip towards the screw head. If the threads
meet the component, the screw tends to tilt parallel to the course of the
threads. This inclined position means that the sliding points cannot be
optimally executed and therefore optimum sliding of the facade cladding is
not possible. The stop collar of the LT-TD screws counteracts this problem
and automatically aligns the screws perpendicular when they hit the stop
collar on the substructure. This guarantees perfectly executed sliding points.

4
Fastening elements for facade claddings

The assembly process – simple, with process-reliability

1. Fixed point 2. Sliding point

1.1 2.1
Insert LT-TD grommet
The grommet is inserted at a slight angle into the factory-made
drill hole in the facade cladding. The snap-on feet are pressed
together and pushed into the drill hole with a tilting movement.

1.2 2.2
Lock grommet
The grommet is pushed through the drilled hole until the snap-
Click Click
on feet on the back of the facade cladding protrude and snap
into place. This way the grommet is securely locked in the
facade cladding.

1.3 2.3
Position LT-TD screw
The centering ring of the grommet is used to position the screw
exactly in the center of the drill hole. The LT/STS tool ensures
reliable screw guidance.

1.4 2.4
Fastening operation
Swarf is produced during screw fastening, which can be
discharged through the air gap between the cladding and the
substructure.

1.5 2.5
Stop collar
The screw is screwed in up to the stop collar. This controls
the exact setting depth for a defined clamping area, ensures
perpendicular alignment of the screw and increases the contact
surface of the grommet between the facade panel and sub-
structure.

1.6 2.6
Installation complete
For the fixed point (1.6), collets of the grommet enclose the
fastener shank and ensure a tight fit of the cladding. The sliding
point (2.6) ensures relative displacement (dilatation) of 3 mm in
all directions.

5
Fastening elements for facade claddings

LT-TD system selection aid

JT4- JT4- JT4- JT4- JT4-


Screw type LT-TD-3-5.5x24/4 LT-TD-3-5.5x26/6 LT-TD-3-5.5x28/8 LT-TD-3-5.5x30/10 LT-TD-3-5.5x32/12
KD16 KD16 KD16 KD16 KD16

Material A2 stainless steel A2 stainless steel A2 stainless steel A2 stainless steel A2 stainless steel

all common all common all common all common all common
Application
facade claddings facade claddings facade claddings facade claddings facade claddings

Approval by
– – – – –
cladding manufacturer

Strip-proof yes yes yes yes yes


Substructure Aluminium Aluminium Aluminium Aluminium Aluminium

Drilling capacity
3.0 3.0 3.0 3.0 3.0
(tI pre-drilled) [mm]

Clamping thickness tfix


4.0 6.0 8.0 10.0 12.0
[mm]

EJOT proof of usability coming soon coming soon coming soon coming soon coming soon

LT-TD grommet for Centring grommet Centring grommet Centring grommet Centring grommet Centring grommet
fixed points (F) TD Ø11/4 F TD Ø11/6 F TD Ø11/8 F TD Ø11/10 F TD Ø11/12 F

LT-TD grommet for Centring grommet Centring grommet Centring grommet Centring grommet Centring grommet
sliding points (S) TD Ø11/4 S TD Ø11/6 S TD Ø11/8 S TD Ø11/10 S TD Ø11/12 S

Availability coming soon coming soon yes coming soon coming soon

6
Fastening elements for facade claddings

JT3- JT3- JT3- JT3- JT3- JT4-


LT-TD-3-5.5x28/4 LT-TD-3-5.5x30/6 LT-TD-3-5.5x32/8 LT-TD-3-5.5x34/10 LT-TD-3-5.5x36/12 LT-2/6-6x50
KD16 KD16 KD16 KD16 KD16 KD16

A2 stainless steel A2 stainless steel A2 stainless steel A2 stainless steel A2 stainless steel
with hardened with hardened with hardened with hardened with hardened A2 stainless steel
steel drill point steel drill point steel drill point steel drill point steel drill point

all common all common all common all common all common all common
facade claddings facade claddings facade claddings facade claddings facade claddings facade claddings

Z-14.4-851
– – – – –
PURICELLI

yes yes yes yes yes yes


Steel / Aluminium Steel / Aluminium Steel / Aluminium Steel / Aluminium Steel / Aluminium Timber / Aluminium

3.0 3.0 3.0 3.0 3.0 1.5 – 2.0

4.0 6.0 8.0 10.0 12.0 8.0

coming soon coming soon coming soon coming soon coming soon ETA-10/0200

Centring grommet Centring grommet Centring grommet Centring grommet Centring grommet Centring grommet
TD Ø11/4 F TD Ø11/6 F TD Ø11/8 F TD Ø11/10 F TD Ø11/12 F TD Ø11/8 F

Centring grommet Centring grommet Centring grommet Centring grommet Centring grommet Centring grommet
TD Ø11/4 S TD Ø11/6 S TD Ø11/8 S TD Ø11/10 S TD Ø11/12 S TD Ø11/8 S

coming soon coming soon yes coming soon coming soon yes

7
EJOT SE & Co. KG
Market Unit Construction
In der Stockwiese 35
57334 Bad Laasphe ∙ Germany
T +49 2752 9080
F +49 2752 908731
[email protected]
www.ejot.com/construction

800-en-global-2025.03.07

Bringing it together.

You might also like