0% found this document useful (0 votes)
56 views1 page

S007 001816 14 TUB PG 0001 07 - RSC - Sugar Dryer Layout Drawing

The document contains a detailed layout and specifications for a sugar dryer system, including various components such as ducts, conveyors, and tanks. It outlines the scope of supply, dimensions, and quantities of equipment needed for the project. Additionally, it includes revision history and confidentiality notes regarding the document's use and distribution.

Uploaded by

josediaz2009
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views1 page

S007 001816 14 TUB PG 0001 07 - RSC - Sugar Dryer Layout Drawing

The document contains a detailed layout and specifications for a sugar dryer system, including various components such as ducts, conveyors, and tanks. It outlines the scope of supply, dimensions, and quantities of equipment needed for the project. Additionally, it includes revision history and confidentiality notes regarding the document's use and distribution.

Uploaded by

josediaz2009
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

A A

Wet Scrubber

B B

5000 2100 03 10
Cold Air duct
1
10 1300_ -+---------------+- i
'
'' 1 '
'' i
' xi
O'
mi
Dust Collection line �¡
e from bel! conveyor 1-I e
<(•

1
1 1
0'
3 111
alvell 1
1
11 21
í
Duct Rec.
1502x952
í - ·o:
.-·-
I!

---'I �
f--.. -7
er wé gtit / \
Ü,
1
pe) 1
1 11 i
1 1 1 11
+17
_l
- - 1 ' 1 11 ---+-_,_+-_, View - H
1 1 1 11 NOTE:
l l--lfL---l.-,,,_,,,1_""""J,1,1-,,,_l,� FFL (0.000) denote 100300mm TOC Slab.

--------r
�====E.:4-JL_ GL denote 100150mm.
D 1----------------------------j D
2007 4647 4000 9134 3036 FC-KCP $COPE OF SUPPLY
Sweet water Tank View - GG
2200 2200
SL NO DESCRIPTION TAG NO QTY
4500 1500 _¡_ - - -
1m Feed Screw Conveyor K4-14-25-130-CV01 1

-
SECTION BB �
3300 2 Sugar Dryer & Cooler K4-14-25-200-DY01 1
OUTLET SUGAR BOX 4700
3300 4700
B e 1571 3 Discharge Screw Conveyor K4-14-25-230-CV01 1
COLD AIR INLET 45 MIXED AIR OUTLET
E 4 Sugar Recovery Screw Conveyor - A K4-14-25-210-CV01 1 E
/
5 Sugar Recovery Screw Conveyor - B K4-14-25-220-CV01 1
L
6 Sugar Dryer air Filler K4-14-25-600-FL0 1 1

Hot air fan (Recirculation) K4-14-25-610-FN01 1


-- ---+111-----+- -
7
1
Mixed Air duct
1 1 1Cooling Towed - 8 Hot air heater K4-14-25-615-HT01 1
111
r+t ! r+t ,------\ .
•1
9 Cold air Filler K4-14-25-700-FL0 1 1
31r :
/ !1 \.1/ !1 \._ 1O Cold air heat exchanger K4-14-25-705-HT01 1
F
ffi1
I> '!
1
1' •1
= Chiller
i----+------------+--------+----jF
11 Air heat exchanger K4-14-25-715-HT01

!I ' 1
1

12 Water Chiller K4-14-25-900-CI01


=
1
Duct Rec.
1 1
...J 2800x1000 1 D §111 fil 13 Chillad water pump K4-14-25-910-PU01
K4-14-25-920-PU01
2
ül Lubrication
" ,.... unit
14 Chillad Water Tank K4-14-25-905-TK01 1
1

1 1
1
e---------------------------
4700 � 3000 1925 : 1280
2200
57( 1571 1 1571 1 1571 18351
1
2774
1 1
3181
-,
-, 1539
3000
1461 ., 700
3214
1 3585 1
1
1400 1
1
D
3765
1
15 K4-14-25-960-PU01
Cold water circulation pump
2
K4-14-25-965-PU01
1 1 1 1

G GIS Roof Structure m------ -- -- ----m1 v,ew - A i----+------------+--------+----jG


16 Extraction Fan K4-14-25-500-FN01
(TSK) 4647 4000 9134 3036 1400 1
m
500 500 17 Scrubber K4-14-25-510-SB01
O
1
4
o::, o::, GIS Roo! Structure 18 Scrubber Sweet Water Tank K4-14-25-550-TK01
a. a.
1
(TSK)
o o \_ 19 Scrubber Sweet Water Pump K4-14-25-560-PU01 2
2400 2400 Platform @ 4000 EL
Coolin Tower SGround level (TSK)
$-- K4-14-25-570-PU01
7500 4500 3500
0 4700 ---� ---- -� · G
Sweet Water
Platform
(TSK)
7100 EL
3
20 K4-14-25-950-CT01
Cooling Towers
K4-14-25-950-CT02
2

H ® SECTION ce
® 3000
1 25
Pump
¡¡¡
i::I 1-----t------------+-------+------i H
MIDDLE SUGAR BOX
Extraction Fan
11-�'' Underground Drain
21 Droplet Separata, K4-14-25-725-FL01 1

� o:: i::
lll -= �
<(1
1
/
(TSK) TSK SCOPE OF SUPPLY

"' -- �' ---


----� SL NO DESCRIPTION
S Ground level ....�
" Dryer Hot air inlet box supporting structure & platform

L o 2 Dryer Mixed air outlet box supporting structure & platform


J o o J
o
3 Dryer Cold air inlet box supporting structure & platform
© 4 Scrubber supporting structure & plalform
1
View - H 5 Dryer Building
¡Chille 11
Hot Air duct 1@ o
o
o ____ J 1

"
6 Chiller, Hot air box, cold air box rain protection shed.

1 <O 1
1

07 Lubrication unit relocated MR MR KS 26-04-2023

ID 1000 Chillad water


,---L�---º 06 Revised as per Mis. TSK Comments MR MR KS 20-03-2023
Pump
G
----
o
05 Revisad as per M/s. TSK Comments MR MR KS 31-12-2022
K K
�-+--- L - - - l C IL OF ·-.
04 Revised as per Mis. TSK Comments MR MR KS 17-11-2022

-Beií Cpnveyo--¡:--'.-
03 Revised as per Mis. TSK Comments MR MR KS 21-10-2022

: '(T�K) 'g 02 Revisad as par M/s. TSK Comments MR MR KS 1&-07-2022

SGround level
01 Revised as per Mis. TSK Comments MR MR KS 06-06-2022
o
+3992
6 CL OF -�1 � o
o
00 FOR COMMENTS MR MR SM 2:.-04-2022

O'. �--+,f .... -BUILDING-+ ;--- �


REY DESCRIPTION DRN CHK APP DATE
w
N
¡ :
+3479
SJ�I\_M_¡r,t-j,,-_ :- · - 7 o
••TSK
CONTRACTOR

o
�I '
1 11
o 11
-------,
LL

■-.,
700 700
ü
DOCUMENT ISSUER PROJECT DOCUMENT CODE
11
...J

--CIJ-
,.
AIR IN 11 Fives Cail-KCP Ud fivescail
------+----------j l
S007-001816-14-TUB-PG-0001
L 1 1630 2835

•ih·d·
CLIENT TSK DOCUMENT CODE
KILOMBERO
SUGAR COMPANY S007-001816-14-TUB-PG-0001
MAflS..O,,oornpani,- AN IILOYO SUI.IJIARICA COMP!INY

7500 4500 1500 11234 1609 1881 111551


PROJECT ISSUER DOCUMENT CODE
KILOMBERO
12000 EXPANSION PROJECT
DRAWING TITLE

® ®
SCALE 1:100 REVISION 07

SECTION DD Sugar Dryer Layout Drawing E] EiB


INLET SUGAR BOX
A1 TSK VERSION o
M 1--�- -+-
- - ---1M
-
PLAN
CD SHEET - NEXT - PROJECT CODE 001816
THE INFORMATION CONTAINEO IN THIS DOCUMENT IS CONFIDENTIAL AND RESTRICTED AND IS TO BE USED ONLY FOR THE PUR POSES ESTABLJSHED N THE DCCUMENT.
NO MODIFICATlON, EXPLOTATION, REPRODI.JCTION, COMMUNICATION TO ANYTHIRD PARTY, DISSEMINA.TION OR DISTRIBUTION OF THEWHOLE OR Al'N PARTOF THE
DOCUMENT IS PERMIITED WITHOUTTHE PRIOR. WRITTEN CONSENT OF TSK FAILURE TO RESPOND TOAl'N REQUEST FOR SUCH CONSENT SHALL IN NOWAY BE
CONSTRUED AS AUTHORIZATION FOR USE.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

You might also like