UL, ULC, CSFM Listed; FM Approved, MINIPLEX Transponders with ES-PS Power Supplies
OTCR/NYC Approved*
Features Introduction
4100ES MINIPLEX transponders connect to a host 4100ES Fire
4100ES Series MINIPLEX transponders allow remotely located
Alarm Control Panel using Simplex remote unit interface (RUI)
initiating and notification functions:
communications. At the transponder, RUI communications are received
• Transponder operation is available as standard or with local mode by the transponder interface module and translated into the same
operation internal communications format that is used in the host control panel.
• Communications with the host fire alarm control panel use the Remotely located modules. With RUI communications, the
Remote Unit Interface (RUI and RUI+) formats transponder can remotely provide the same initiating and notification
Initiating functions include: functions that occur at the host control panel without requiring multiple
long distance wiring runs. Connections to the host panel are low current
• Conventional initiating device circuit (IDC) support
communications and audio wiring with distances up to 2500 ft (762 m).
• Addressable device support including TrueAlarm analog sensor
compatibility Please refer to document S4100-1031 and the other documents listed
in Additional 4100ES Product Reference for additional information
Notification functions include: concerning the extensive initiating and notification features of the
• Addressable strobe and horn notification using enhanced power 4100ES fire alarm control panels.
delivery IDNAC SLCs Figure 1: Typical 4100ES MINIPLEX System One-Line Drawing
• Conventional DC notification appliance circuits including TrueAlert
strobe and horn appliances
• Emergency voice/alarm communications
* Additional listings may be applicable; contact your local Simplex product supplier for the latest status.
Packaging Availability
• Modules are power-limited (except as noted, such as battery chargers, city circuits and relay modules)
• Enclosure are available for one, two, or three bay sizes or for cabinet rack mounting
• NEMA 1/IP30 boxes and solid doors are available in platinum or red (ordered separately)
• Up to eight close-nippled cabinets can be connected at one transponder location (close-nippled is mounted within 20 ft (6 m) and with
interconnecting wiring enclosed in conduit)
• Refer to document S4100-0037 for enclosure details.
Size Definitions: Block = 4" W x 5" H (102 mm x 127 mm) card area
Slot = 2" W x 8" H (51 mm x 203 mm) motherboard with daughter card
Description Mounting
Transponder Interface Modules Block A
Audio Riser Modules Block B
Terminal Block Module 1 Block
IDNet 2 and IDNet 2+2 Modules 1 Block
4, 2 A Relays 1 Block
4, 10 A Relays NON Power-limited 4", 2 Slots
8, 3 A Relays 1 Block
VESDA Interface 2", 1 Slot
8 Point Zone/Relay Card 1 Block
Class B IDC 2", 1 Slot
Class A IDC 2", 1 Slot
MAPNET II Module 4", 2 Slots
MAPNET II Isolator 2", 1 Slot
Decoder Module 6", 3 Slots
Flex-35 Amplifiers, 2 max /bay* Blocks E & F; C & D; or A & B
Flex-50 Amplifiers, 2 max/bay* Blocks E & F or C & D
100 W Amplifiers, 1 max/bay Blocks E, F, G & H
100 W Backup Amplifiers, 1 max. per bay with primary amplifier Blocks A, B, C & D
Telephone Expansion Module 1 Block
Expansion Signal Module 1 Block
NAC Card 1 Block
IDNAC Card 2 Blocks (on ES Power Supply only)
ES-PS Blocks G & H ONLY
ES-PS Configured as backup Blocks E & F ONLY
ES-XPS 2 Blocks
Note: * When mounting dual Flex amplifiers on an expansion bay, special mounting rules apply.
General Specifications
Table 1: ES Power Supply Specifications (ES-PS and ES-XPS)
Specifications Rating
AC Input Power 120-240 VAC
120 VAC 3.72 A
220 - 240 VAC 1.82 A
Total DC Output Power Capacity
Without Fan 9.5 A
With 4100-5131 Fan and 4100-5451 IDNAC Module(s) 9.7 A
With 4100-5131 Fan (without 4100-5451 IDNAC Module) 12.7 A
With Regulated 24V Appliance Loads (with or without 4100-5131 Fan) 5.0 A
Special Application Appliance Loads: supports full total DC output Simplex horns, strobes, and combination horn/strobes and speaker/
power capacity ratings above strobes (contact your Simplex product representative for compatible
appliances)
Regulated 24V Appliances: reduces total DC output power capacity to Power for other UL listed appliances; use associated external
5.0 A synchronization modules where required
Auxiliary Power Tap 2 A maximum (taken from total output power capacity)
NACs Programmed for Auxiliary Power 3 A maximum per NAC, 5 A maximum total (taken from total output power
capacity)
Battery Charger (ES-PS only) Sealed Lead-Acid Batteries
Battery Ah Capacity UL/ULC listed for battery charging of up to 110 Ah (batteries larger than 50
Ah require a remote battery cabinet)
Charger characteristics and performance Temperature compensated, dual rate, recharges depleted batteries within
48 hours
Environmental
Operating Temperature 32 °F to 120 °F (0 °C to 49 °C)
Operating Humidity Up to 93% RH, non-condensing @ 90 °F (32 °C) maximum
Option Card Mounting 2 vertical blocks are available for compatible modules (refer to 579-1288
installation instructions for additional details)
Note:
1. Battery charger is only available on the ES-PS power supply.
2. When an ES-PS is used to power Flex-35 or Flex-50 Amplifiers the ES-PS battery charger is not available.
Table 2: IDNet, MAPNET II, IDNet 2, and IDNet 2+2 SLC Wiring Common Specifications
Specification Description
Maximum Distance from Control Panel per Device 1 to 125 4000 ft (1219 m); 50 ohms
Load 126 to 250 2500 ft (762 m); 35 ohms
2 2
Connections Terminals for 18 to 12 AWG (0.82 mm to 3.31 mm )
Table 3: IDNet and MAPNET II Specifications
Specification Description
Wire Type New Installation Shielded twisted pair (STP)
Retrofit Only Unshielded twisted pair (UTP)
Total Wire Length Allowed With "T" Taps for Class B Wiring Up to 10,000 ft (3 km); 0.58 μF
Note: For retrofit installations consult with your local Simplex product supplier, restrictions may apply.
Table 4: IDNet 2 and IDNet 2+2 Wiring Specifications
Specification Description
Wire Type New Installation Unshielded twisted pair (UTP)
Retrofit Only Shielded or unshielded, twisted or untwisted wire
Total Wire Length Allowed With "T" Taps for Class B Wiring Up to 12,500 ft (3.8 km); 0.60 μF
Maximum Capacitance Between IDNet 2 Channels 1 μF
IDNet 2 and IDNet 2+2 Module Compatibility: IDNet communicating devices and TrueAlarm sensors including QuickConnect and QuickConnect2
sensors
4100-0633 Door Tamper Switch, connects into Transponder Interface Module, one per cabinet assembly if required
4100-0634 120 VAC Power Distribution Module (PDM) select per system voltage; one required per box
4100-0635 220/230/240 VAC Power Distribution Module (PDM) select per system voltage; one required per box
2081-9031 Series resistor for WSO, IDCs (N.O. water flow and tamper on same circuit, wires after water flow and before tamper) 470 Ω, 1 W,
2
encapsulated, two 18 AWG leads (0.82 mm ), 2 ½" L x 1 ⅜" W x 1" H (64 mm x 35 mm x 25 mm)
Table 16: Audio Riser Modules
SKU Description Size Supv. Alarm
4100-0621 Dual Channel Analog Audio Riser Module; accepts one or two separate audio signals from 1 Block 0 mA 15 mA
host control panel; mounts in Block B, is controlled by Transponder Interface Module
4100-0622 3-8 Channel Digital Audio Riser Module; similar to analog module, except receives and 1 Block 70 mA 70 mA
decodes a digital input signal with up to eight audio channels; with Non-Alarm Audio input
Table 17: Analog Emergency Voice/Alarm Communications Equipment, Constant Supervision Compatible*
SKU Description Details
4100-1361 25 VRMS output Flex-35, 35 W Amplifier, constant Includes three on-board Class B audio NAC rating = 1.4 A 35 W,
4100-1362 70.07 VRMS output supervision compatible NACs; power is supplied from an ES-PS NAC rating = 0.5 A or 100
speakers
4100-1312 25 VRMS output Flex-50, 50 W Amplifier, constant NAC rating = 2 A 50 W,
4100-1313 70.7 VRMS output supervision compatible NAC rating = 0.707 A or 100
speakers
* Refer to document S4100-1034 for additional audio information.
Table 18: 100 W Analog Amplifiers with Power Supply, Constant Supervision Compatible
SKU/Output Voltage Power Supply Input/Listing Description Details
25 VRMS 70.7 VRMS
4100-1314 4100-1315 120 VAC, 60 Hz UL Primary 100 W Includes six, Class B audio NACs; NAC rating = 50 W or 100
Amplifier speakers maximum; 2 A @ 25 VRMS; 1.4 A @ 70.7 VRMS
4100-1316 4100-1317 120 VAC, 60 Hz ULC Primary 100 W Includes six, Class B audio NACs; NAC rating = 50 W or 100
Amplifier speakers maximum; 2 A @ 25 VRMS; 1.4 A @ 70.7 VRMS
ULC models have low battery dropout circuit
4100-1318 4100-1319 220/230/240 VAC, UL Primary 100 W Includes six, Class B audio NACs; NAC rating = 50 W or 100
50/60 Hz Amplifier speakers maximum; 2 A @ 25 VRMS; 1.4 A @ 70.7 VRMS
4100-1320 4100-1321 120 VAC, 60 Hz UL Backup 100 W Uses the six Class B NACs of primary amplifier
Amplifier
4100-1322 4100-1323 120 VAC, 60 Hz ULC Backup 100 W Uses the six Class B NACs of primary amplifier
Amplifier ULC models have low battery dropout circuit
4100-1324 4100-1325 220/230/240 VAC, UL Backup 100 W Uses the six Class B NACs of primary amplifier
50/60 Hz Amplifier
Note: Matching box is supplied with surface mount models 4601-9109 (red) and 4601-9111 (beige); for semi-flush models 4601-9110 (beige), use a
1-1/2" (38 mm) minimum depth, 3-gang box.
Note:
1. Side View dimensions are shown with minimal cabinet and door protrusion from the exterior wall. For 6 inch stud construction with minimum
protrusion shown, the door will open 90 degrees. To allow the door to open 180 degrees, the exposed cabinet dimension from the exterior wall
must be a minimum of 3 inches (76 mm) for both 4 inch and 6 inch stud construction.
2. A system ground must be provided for Earth Detection and transient protection devices. This connection shall be made to an approved,
dedicated Earth connection per NFPA 70, Article 250, and NFPA 780.
© 2024 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without
notice. Additional listings may be applicable, contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co.
Simplex, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are
registered trademarks of the National Fire Protection Association (NFPA).
S4100-1035 Rev. 7 08/2024