Job No Sheet No Rev

1
Part
Software licensed to
Job Title Ref

By Date07-Feb-25 Chd

Client File Date/Time


E&H_Entrance Corner Double Height.STD
15-May-2025 16:00

X = 5.412 kN
Y = 11.799 kN
Z = 2.739 kN
MX = FREE
MY = FREE
MZ = FREE

X = -3.744 kN
Y = FREE
Y Z = -2.517 kN
X MX = FREE
Z MY = 0.005 kNm Load 3
MZ = FREE
Design of Bracket Plates
(As per IS 800- 2007, clause 7.4.3)

Factored Load (refer staad report)


P = 17.70 kN
Vy = 8.12 kN
Vz = 4.1085 kN

Material Properties (Mild Steel)


3
Density = 7850 kg/m
Elastic Modulus = 200000 MPa
Yield Stress (fy) = 250 MPa
Ultimate Stress (fu) = 410 MPa
Material Factor γmo = 1.1

Permissible Stresses (IS 800:2007)


Bending and overall yielding(fb) = 227.3 MPa (Fy/γmo)
Shear (fs) = 131.2 MPa (Fy/√3γmo)
Axial Tension/Compression (fa) = 227.3 MPa (Fy/γmo)
Bearing (fbr) = 227.3 MPa (Fy/γmo)

Design of Vertical Plate

Dimention of Plate
Height (H) = 180 mm
Depth (D) = 200 mm
Thickness (t) = 10 mm
No. of Plates (n) = 1

Physical Properties of Plate


2
Area (A) = 2000 mm (t*D)
4 3
Moment of Inertia (Izz) = 6666667 mm (t*D )/12
3 2
Section Modulus (Zzz) = 66666.67 mm (t*D )/6
4 3
Moment of Inertia (Iyy) = 16666.67 mm (D*t )/12
3 2
Section Modulus (Zyy) = 3333.333 mm (D*t )/6

Load Eccentricity
Wind Load Eccentricity [e] = 130 mm
Bending Moment at base of plate (Mz) = 1.06 kN-m (Vy*e)
Bending Moment at base of plate (Mx) = 0.53 kN-m (Vz*e)

Check for Stresses


Bending Stresses (zz Dir)
Maximum Bending Stress Developed per plate = 15.83 MPa (M z/n*Zzz)
< 227.27 MPa
SAFE
Bending Stresses (xx Dir)
Maximum Bending Stress Developed per plate = 160.23 MPa (M x/n*Zxx)
< 0.00 MPa
SAFE
Shear Stress (zz Dir.)
Maximum Shear Stress Developed per Plate = 4.06 MPa (Vy/n*A)
< 131.22 MPa
SAFE
Shear Stress (xx Dir.)
Maximum Shear Stress Developed per Plate = 2.05 MPa (Vz/n*A)
< 0.00 MPa
SAFE

Tensile Stress
Dia of Bolt Provided d = 10 mm
Dia of Bolt Hole do = 12 mm
2
Area of Bolt Hole Ao = 120.00 mm (do*t)
2
Net area at critical Section Anet = 1880.00 mm (A-Ao)
Maximum Tensile Stress Developed per Plate = 9.41 MPa (P/n*A net)
< 227 MPa
SAFE

Check Vertical Plate for Compression


Radius of Gyration of plate (ry) = 2.89 mm
Length of Plate = 180 mm
Slenderness Ratio = 62.4

Permissible Compressive Stress (from table 9(a), IS800:2007)


fcd = 28.3. MPa
Maximum Compressive Stress developed = 9.41 MPa
< 28.3. MPa
SAFE

Check for End Shear Capacity of Plate


Edge distance eo = 50 mm
Dia of hole do = 12 mm
net edge distance enet = 44 mm [eo-(d0/2)]
2
Effective Shear Area As = 440 mm (enet*t)
End Shear Capacity of Plate = 40.22 MPa [(P)/(n*As)]
> 131.22 MPa
SAFE

Vertical Plates is Safe in Stress

refer HILTI anchor rerport for Base plate design

Check for Weld Connection

Input Data
for Fe 410,
Fy = 250 MPa
Fu = 410 MPa
Safety factor of Weld = 1.25 (for Shop Weld)
1.5 (for Site Weld)
𝑓
𝑓 =
3 × 1.25
Permissible shear Stress of Weld
fw = 189.37 MPa (Considering Shop Weld)

Weld Parameter
Asumme Size of Weld (S) = 7 mm
Throat Thickness (tt) = 4.9 mm
Length of Weld at vertical plate (Lvw) = 200 mm
2
Area of Weld per plate (Aw) = 980 mm

Moment of Inertia of Weld


4 3
Ixx = 3266666.67 mm (tt*Lvw )/12
4 3
Izz = 1960.817 mm (Lvw*tt )/12

Sectiom Modulas of weld


3 2
Zxx = 32666.667 mm (tt*Lvw )/6
3 2
Zzz = 800.333 mm (Lvw*tt )/6

Stress Calculation

τp = 2.07 MPa P/n*Aw


τvx = 4.51 MPa Vx/n*Aw
τvz = 1.05 MPa Vz/n*Aw
σMx = 8.08 MPa Mx/n*Zxx
σMz = 166.84 MPa Mz/n*Zzz

Check for Stress Combination

𝑃 𝑉 𝑉 𝑀 𝑀
+ + + + = 182.55 MPa
𝐴 𝐴 𝐴 𝑍 𝑍
< 189.37 MPa

SAFE

Provide 200mm length and 7 mm thick weld at either side of plate


CHECK FOR THROUGH BOLT

Stainless Steel Bolts Conforming to - Grade A2/A4 (Property Class 70), BS-EN-ISO 3506
Bolt and Plate Parameter

Diameter of the bolt d = 10 mm


Diameter of the bolt hole d0 = 12 mm
No. of Bolts (nb) = 2
No. of interfaces (ni) = 2
Thickness of Mullion profile (ta) = 3 mm
Ultimate tensile strength of stainless steel (bolt) (fub) = 700 N/mm2
Yield strength of stainless steel (bolt) (fyb) = 450 N/mm2
Yield Strength of Plate (MS) (fy) = 250 N/mm2
Ultimate strength of Plate (MS) (fu) = 410 N/mm2
Bracket Plate Thickness (T1) = 10 mm

Factored Force acting on Bolt


Horizontal Compression Force (Hc) = 17.70 kN
Vertical Force (Vu) = 8.12 kN
Vertical Force (Vv) = 4.11
1.Check for Bolt Shear: (5.1, SCI Publication P291 )
Max vertical S.F per Bolt (Vvb) = 3.06 kN (V/(nb x ni))/n
Max Horizontal S.F per Bolt (Vhb) = 4.42 kN (H/(nb x ni))/n
Resultant S.F per bolt (V) = 5.38 kN ( Vvb2 + Vhb2 )0.5
for fub ≤ 800 N/mm2
Shear strength of Bolt p sb = 336 N/mm2 (0.48fub)
< 310.5 N/mm2 (0.69fyb
Gross Area Ag = 78.57 mm2 ((22/7)*d2/4)
Shear Area As = 58.93 mm2 (0.75*A g)
Shear Capacity of Bolt (Psb) = 19.80 kN (p sb A s)
Resultant Shear Force per bolt (Rf) = 5.38 kN
Utilization Ratio 0.27 HENCE O.K.

2.Check for Bearing, considering Aluminium profile thickness


Allowable bearing stress in Mullion Pbs = 139 N/mm2
Bearing capacity of Aluminium profile thickness = 4.17 kN (Pbs*d*ta )
resultant Unfactored force per bolt in Mullion Profile = 3.59 kN (Rf)/1.5
Utilization Ratio (Mullion Profile) = 0.860 HENCE O.K.

3.Check for Bolt Bearing, considering MS bracket plate & edge distance : (Clause 10.3.4, IS 800:2007)
Edge Distance e = 55 mm
Pitch distance p = 50 mm
kb = 1.00 kb = MIN (e/(3do), (p /3do)-0.25, fub/fu, 1)
Nominal Bearing Strength of a bolt (Vnpb) = 62.50 kN (2.5 x kb x d x T1 x fu)
Design bearing strength of Bolt (Vdpb) = 50.00 kN (Vnpb/γmb)
Utilization Ratio = 0.11 HENCE O.K.
Project: E&H
Mumbai Application: Corner Entrance Double Height Top Bracket
India

3/26/2025 DesignFiX 3.5.9264.429

Supplier: Klimas Sp. z o.o


ul. Wincentego 135/137 | 42-233 Mykanów, POLAND
Phone: +48 (34) 377 71 00, E-mail: [email protected]
Product: Klimas Sp. z o.o
LE-A4 - Material: A4
LE-A4-10095 - Item no. LE-A4-10095
Further products: See notes.
Design method: EN 1992-4:2018, method A
Approval: ETA-20/0641 | 12/28/2023

Base material: Uncracked concrete C30/37


No or normal reinforcement
Installation: Through-bolting | Hammer drilling | Annular gap not filled
Embedment depth: hef = 60 mm | Drill hole depth min. = 74 mm
Base plate: Rectangular 250 • 200 • 12
Profile: none selected
Load: Static / quasi-static | αsus = 0.60 | ψsus = 0.00
Units: Load [kN, kNm] | Dimensions [mm], * Not drawn to scale

The design results must be checked for plausibility and fulfill the conditions of local standards and approvals. Page 1 of 4
3/26/2025 DesignFiX 3.5.9264.429

Anchor forces [kN]: Concrete:


Anchor N V Vx Vy Max. compression 0.30 [‰]
1 14.45 4.55 2.06 -4.06 Max. compressive stress:9.02 N/mm²
2 15.86 4.55 2.06 -4.06 Resultant tension load: 30.31 kN
xZ / yZ: 3 / 0 mm
Resultant compression 11.62 kN
force:
xD / yD: -37 / -95 mm

Tension load
Steel failure
h
N Ed < N Rk,s / γ Ms

15.86 < 28.50 / 1.62 = 17.59 kN


Utilization: β N,s = 90.1%

Concrete cone failure


0 0
N Rk,c = N Rk,c · (A c,N / A c,N ) · ψ s,N · ψ re,N · ψ ec,N,x · ψ ec,N,y · ψ M,N
g
N Ed < N Rk,c / γ Mc

The fastening consists of one group.


Anchor no. 1, 2
N Rk,c = 28.00 · (59400 / 32400 ) · 1.000 · 1.000 · 0.963 · 1.000 · 1.000 = 49.42 kN
30.31 < 49.42 / 1.50 = 32.95 kN
Utilization: βN,c = 92.0%

Pull-out
According to ETA no pull-out proof is required!

Splitting
According to design method no splitting proof is required!

Shear loads

Steel Resistance (without lever arm)


h
V Ed < V Rk,s / γ Ms

4.55 < 20.30 / 1.35 = 15.04 kN


Utilization: β V,s = 30.3%

Concrete edge
0 0
V Rk,c = V Rk,c · (A c,V / A c,V ) · ψ s,V · ψ h,V · ψ α,V · ψ ec,V · ψ re,V

V Ed < V Rk,c / γ Mc

The design results must be checked for plausibility and fulfill the conditions of local standards and approvals. Page 2 of 4
3/26/2025 DesignFiX 3.5.9264.429

Front edge -Y (c = 155 mm)


The fastening consists of one group.
Anchor no. 1, 2
V Rk,c = 37.09 · (130380 / 108113 ) · 1.000 · 1.047 · 1.087 · 1.000 · 1.000 = 50.90 kN
9.10 < 50.90 / 1.50 = 33.93
Utilization: βV,c = 26.8%

Concrete pry-out failure at the side opposite to load direction:


0 0
V Rk,cp = k · N Rk,c · (A c,N / A c,N ) · ψ s,N · ψ re,N · ψ ec,N,x · ψ ec,N,y
g
V Sd < V Rk,cp / γ Mcp

The fastening consists of one group.


Anchor no. 1, 2
V Rk,cp = 2.0 · 28.00 · (59400 / 32400 ) · 1.000 · 1.000 · 1.000 · 1.000 = 102.67 kN
9.10 < 102.67 / 1.50 = 68.45
Utilization: βV,cp = 13.3%
Interaction:
βN + βV > 1.2
0.920 + 0.268 = 1.188 < 1.2

Summary of the design results:


Failure mode Utilization
Tension load Steel failure 90.1%
Concrete failure 92.0%
Shear loads Steel failure 30.3%
Concrete edge 26.8%
Concrete pry-out failure at the side 13.3%
opposite to load direction
Interaction 99.0%
Proof of anchor was successful!

The design results must be checked for plausibility and fulfill the conditions of local standards and approvals. Page 3 of 4
3/26/2025 DesignFiX 3.5.9264.429

Notes:
The design results are based essentially on the conditions defined by the user of the software and on the data entered
by them. However, the end-user bears the sole responsibility for the absence of errors and their completeness.
Furthermore, the end-user is solely responsible for having the results of the calculation checked and cleared by an
expert prior to using them for the specific application. This is especially true with regard to the compliance with
applicable standards and approvals. DesignFiX serves only as an aid to interpret the standards and approvals without
any guarantee to the absence of errors. All conditions of the approval (ETA-20/0641) are to be observed.

As a pre-condition it is assumed that the anchor plate does not deform under the design actions. The DesignFiX anchor
plate design is based on a proof of stresses and does not allow a statement about the stiffness of the plate. The proof
of the necessary stiffness is not carried out by DesignFiX.

To ensure the structural component's capacity, the proofs in accordance with EN 1992-4:2018, Annex A must be
observed.

Products:
LE-A4-10095 - Item no. LE-A4-10095
LE-A4-10105 - Item no. LE-A4-10105
LE-A4-10115 - Item no. LE-A4-10115
LE-A4-10135 - Item no. LE-A4-10135
LE-A4-10155 - Item no. LE-A4-10155

The design results must be checked for plausibility and fulfill the conditions of local standards and approvals. Page 4 of 4
Design of Bracket Plates
(As per IS 800- 2007, clause 7.4.3)

Factored Load (refer staad report)


P = 0.00 kN
Vy = 5.62 kN
Vz = 3.78 kN

Material Properties (Mild Steel)


3
Density = 7850 kg/m
Elastic Modulus = 200000 MPa
Yield Stress (fy) = 250 MPa
Ultimate Stress (fu) = 410 MPa
Material Factor γmo = 1.1

Permissible Stresses (IS 800:2007)


Bending and overall yielding(fb) = 227.3 MPa (Fy/γmo)
Shear (fs) = 131.2 MPa (Fy/√3γmo)
Axial Tension/Compression (fa) = 227.3 MPa (Fy/γmo)
Bearing (fbr) = 227.3 MPa (Fy/γmo)

Design of Vertical Plate

Dimention of Plate
Height (H) = 130 mm
Depth (D) = 200 mm
Thickness (t) = 10 mm
No. of Plates (n) = 1

Physical Properties of Plate


2
Area (A) = 2000 mm (t*D)
4 3
Moment of Inertia (Izz) = 6666667 mm (t*D )/12
3 2
Section Modulus (Zzz) = 66666.67 mm (t*D )/6
4 3
Moment of Inertia (Iyy) = 16666.67 mm (D*t )/12
3 2
Section Modulus (Zyy) = 3333.333 mm (D*t )/6

Load Eccentricity
Wind Load Eccentricity [e] = 90 mm
Bending Moment at base of plate (Mz) = 0.51 kN-m (Vy*e)
Bending Moment at base of plate (Mx) = 0.34 kN-m (Vz*e)

Check for Stresses


Bending Stresses (zz Dir)
Maximum Bending Stress Developed per plate = 7.58 MPa (M z/n*Zzz)
< 227.27 MPa
SAFE
Bending Stresses (xx Dir)
Maximum Bending Stress Developed per plate = 101.94 MPa (M x/n*Zxx)
< 0.00 MPa
SAFE
Shear Stress (zz Dir.)
Maximum Shear Stress Developed per Plate = 2.81 MPa (Vy/n*A)
< 131.22 MPa
SAFE
Shear Stress (xx Dir.)
Maximum Shear Stress Developed per Plate = 1.89 MPa (Vz/n*A)
< 0.00 MPa
SAFE

Tensile Stress
Dia of Bolt Provided d = 10 mm
Dia of Bolt Hole do = 12 mm
2
Area of Bolt Hole Ao = 120.00 mm (do*t)
2
Net area at critical Section Anet = 1880.00 mm (A-Ao)
Maximum Tensile Stress Developed per Plate = 0.00 MPa (P/n*A net)
< 227 MPa
SAFE

Check Vertical Plate for Compression


Radius of Gyration of plate (ry) = 2.89 mm
Length of Plate = 130 mm
Slenderness Ratio = 45.0

Permissible Compressive Stress (from table 9(a), IS800:2007)


fcd = 28.3. MPa
Maximum Compressive Stress developed = 0.00 MPa
< 28.3. MPa
SAFE

Check for End Shear Capacity of Plate


Edge distance eo = 40 mm
Dia of hole do = 12 mm
net edge distance enet = 34 mm [eo-(d0/2)]
2
Effective Shear Area As = 340 mm (enet*t)
End Shear Capacity of Plate = 0.00 MPa [(P)/(n*As)]
> 131.22 MPa
SAFE

Vertical Plates is Safe in Stress

refer HILTI anchor rerport for Base plate design

Check for Weld Connection

Input Data
for Fe 410,
Fy = 250 MPa
Fu = 410 MPa
Safety factor of Weld = 1.25 (for Shop Weld)
1.5 (for Site Weld)
𝑓
𝑓 =
3 × 1.25
Permissible shear Stress of Weld
fw = 189.37 MPa (Considering Shop Weld)

Weld Parameter
Asumme Size of Weld (S) = 6 mm
Throat Thickness (tt) = 4.2 mm
Length of Weld at vertical plate (Lvw) = 200 mm
2
Area of Weld per plate (Aw) = 840 mm

Moment of Inertia of Weld


4 3
Ixx = 2800000.00 mm (tt*Lvw )/12
4 3
Izz = 1234.800 mm (Lvw*tt )/12

Sectiom Modulas of weld


3 2
Zxx = 28000.000 mm (tt*Lvw )/6
3 2
Zzz = 588.000 mm (Lvw*tt )/6

Stress Calculation

τp = 1.67 MPa P/n*Aw


τvx = 0.00 MPa Vx/n*Aw
τvz = 1.12 MPa Vz/n*Aw
σMx = 4.51 MPa Mx/n*Zxx
σMz = 144.47 MPa Mz/n*Zzz

Check for Stress Combination

𝑃 𝑉 𝑉 𝑀 𝑀
+ + + + = 151.78 MPa
𝐴 𝐴 𝐴 𝑍 𝑍
< 189.37 MPa

SAFE

Provide 180 mm length and 5 mm thick weld at either side of plate


CHECK FOR THROUGH BOLT

Stainless Steel Bolts Conforming to - Grade A2/A4 (Property Class 70), BS-EN-ISO 3506
Bolt and Plate Parameter

Diameter of the bolt d = 10 mm


Diameter of the bolt hole d0 = 12 mm
No. of Bolts (nb) = 1
No. of interfaces (ni) = 2
Thickness of Mullion profile (ta) = 3 mm
Ultimate tensile strength of stainless steel (bolt) (fub) = 700 N/mm2
Yield strength of stainless steel (bolt) (fyb) = 450 N/mm2
Yield Strength of Plate (MS) (fy) = 250 N/mm2
Ultimate strength of Plate (MS) (fu) = 410 N/mm2
Bracket Plate Thickness (T1) = 10 mm

Factored Force acting on Bolt


Horizontal Compression Force (Hc) = 0.00 kN
Vertical Force (Vu) = 5.62 kN

1.Check for Bolt Shear: (5.1, SCI Publication P291 )


Max vertical S.F per Bolt (Vvb) = 2.81 kN (V/(nb x ni))/n
Max Horizontal S.F per Bolt (Vhb) = 0.00 kN (H/(nb x ni))/n
Resultant S.F per bolt (V) = 2.81 kN ( Vvb2 + Vhb2 )0.5
for fub ≤ 800 N/mm2
Shear strength of Bolt p sb = 336 N/mm2 (0.48fub)
< 310.5 N/mm2 (0.69fyb
Gross Area Ag = 78.57 mm2 ((22/7)*d2/4)
Shear Area As = 58.93 mm2 (0.75*A g)
Shear Capacity of Bolt (Psb) = 19.80 kN (p sb A s)
Resultant Shear Force per bolt (Rf) = 2.81 kN
Utilization Ratio 0.14 HENCE O.K.

2.Check for Bearing, considering Aluminium profile thickness


Allowable bearing stress in Mullion Pbs = 139 N/mm2
Bearing capacity of Aluminium profile thickness = 4.17 kN (Pbs*d*ta )
resultant Unfactored force per bolt in Mullion Profile = 1.87 kN (Rf)/1.5
Utilization Ratio (Mullion Profile) = 0.449 HENCE O.K.

3.Check for Bolt Bearing, considering MS bracket plate & edge distance : (Clause 10.3.4, IS 800:2007)
Edge Distance e = 55 mm
Pitch distance p = 50 mm
kb = 1.00 kb = MIN (e/(3do), (p /3do)-0.25, fub/fu, 1)
Nominal Bearing Strength of a bolt (Vnpb) = 62.50 kN (2.5 x kb x d x T1 x fu)
Design bearing strength of Bolt (Vdpb) = 50.00 kN (Vnpb/γmb)
Utilization Ratio = 0.06 HENCE O.K.
Project: E&H
Mumbai Application: Corner Entrance Double Height Bottom Bracket
India

3/26/2025 DesignFiX 3.5.9264.431

Supplier: Klimas Sp. z o.o


ul. Wincentego 135/137 | 42-233 Mykanów, POLAND
Phone: +48 (34) 377 71 00, E-mail: [email protected]
Product: Klimas Sp. z o.o
LE-A4 - Material: A4
LE-A4-10095 - Item no. LE-A4-10095
Further products: See notes.
Design method: EN 1992-4:2018, method A
Approval: ETA-20/0641 | 12/28/2023

Base material: Uncracked concrete C30/37


No or normal reinforcement
Installation: Through-bolting | Hammer drilling | Annular gap not filled
Embedment depth: hef = 60 mm | Drill hole depth min. = 74 mm
Base plate: Rectangular 250 • 200 • 12
Profile: none selected
Load: Static / quasi-static | αsus = 0.60 | ψsus = 0.00
Units: Load [kN, kNm] | Dimensions [mm], * Not drawn to scale

The design results must be checked for plausibility and fulfill the conditions of local standards and approvals. Page 1 of 4
3/26/2025 DesignFiX 3.5.9264.431

Anchor forces [kN]: Concrete:


Anchor N V Vx Vy Max. compression 0.11 [‰]
1 2.48 3.39 1.89 -2.81 Max. compressive stress:3.16 N/mm²
2 3.13 3.39 1.89 -2.81 Resultant tension load: 5.61 kN
xZ / yZ: 9 / 0 mm
Resultant compression 5.61 kN
force:
xD / yD: -52 / -91 mm

Tension load
Steel failure
h
N Ed < N Rk,s / γ Ms

3.13 < 28.50 / 1.62 = 17.59 kN


Utilization: β N,s = 17.8%

Concrete cone failure


0 0
N Rk,c = N Rk,c · (A c,N / A c,N ) · ψ s,N · ψ re,N · ψ ec,N,x · ψ ec,N,y · ψ M,N
g
N Ed < N Rk,c / γ Mc

The fastening consists of one group.


Anchor no. 1, 2
N Rk,c = 28.00 · (59400 / 32400 ) · 1.000 · 1.000 · 0.912 · 1.000 · 1.000 = 46.80 kN
5.61 < 46.80 / 1.50 = 31.20 kN
Utilization: βN,c = 18.0%

Pull-out
According to ETA no pull-out proof is required!

Splitting
According to design method no splitting proof is required!

Shear loads

Steel Resistance (without lever arm)


h
V Ed < V Rk,s / γ Ms

3.39 < 20.30 / 1.35 = 15.04 kN


Utilization: β V,s = 22.5%

The design results must be checked for plausibility and fulfill the conditions of local standards and approvals. Page 2 of 4
3/26/2025 DesignFiX 3.5.9264.431

Concrete pry-out failure at the side opposite to load direction:


0 0
V Rk,cp = k · N Rk,c · (A c,N / A c,N ) · ψ s,N · ψ re,N · ψ ec,N,x · ψ ec,N,y
g
V Sd < V Rk,cp / γ Mcp

The fastening consists of one group.


Anchor no. 1, 2
V Rk,cp = 2.0 · 28.00 · (59400 / 32400 ) · 1.000 · 1.000 · 1.000 · 1.000 = 102.67 kN
6.77 < 102.67 / 1.50 = 68.45
Utilization: βV,cp = 9.9%
Interaction:
1.5 1.5
β N + β V < 1.0
0.1801.5 + 0.0991.5 = 0.107 < 1.0

Summary of the design results:


Failure mode Utilization
Tension load Steel failure 17.8%
Concrete failure 18.0%
Shear loads Steel failure 22.5%
Concrete pry-out failure at the side 9.9%
opposite to load direction
Interaction 10.7%
Proof of anchor was successful!

The design results must be checked for plausibility and fulfill the conditions of local standards and approvals. Page 3 of 4
3/26/2025 DesignFiX 3.5.9264.431

Notes:
The design results are based essentially on the conditions defined by the user of the software and on the data entered
by them. However, the end-user bears the sole responsibility for the absence of errors and their completeness.
Furthermore, the end-user is solely responsible for having the results of the calculation checked and cleared by an
expert prior to using them for the specific application. This is especially true with regard to the compliance with
applicable standards and approvals. DesignFiX serves only as an aid to interpret the standards and approvals without
any guarantee to the absence of errors. All conditions of the approval (ETA-20/0641) are to be observed.

As a pre-condition it is assumed that the anchor plate does not deform under the design actions. The DesignFiX anchor
plate design is based on a proof of stresses and does not allow a statement about the stiffness of the plate. The proof
of the necessary stiffness is not carried out by DesignFiX.

To ensure the structural component's capacity, the proofs in accordance with EN 1992-4:2018, Annex A must be
observed.

Products:
LE-A4-10095 - Item no. LE-A4-10095
LE-A4-10105 - Item no. LE-A4-10105
LE-A4-10115 - Item no. LE-A4-10115
LE-A4-10135 - Item no. LE-A4-10135
LE-A4-10155 - Item no. LE-A4-10155

The design results must be checked for plausibility and fulfill the conditions of local standards and approvals. Page 4 of 4