DMA-80 Technical Specifications MILESTONE
H E L P I N G
C H E M I S T S
DMA-80 Wide Range DMA-80 Dual Cell DMA-80 Tri Cell
Principle Sample thermal decomposition, amalgamation, atomic absorption
Typical analysis time 5 minutes
Sample loading
Auto-sampler Built-in, 2x40 plates with ‘on-the-fly’ samples loading
Sample type Solid, liquid and gas
Max. sample weight (solid) 1,5 gram
Max. sample volume (liquid) 1,5 mL
Mercury detection
Carrier gas Air or oxygen
Input pressure 4 bar
Flow Ca. 100 mL/minute
Sample boat Multiple materials available
Combustion furnace Catalyst-filled quartz tube with dual-temperature zone
Combustion temperature Time-to-temperature and time-at-temperature programs
Mercury detection
Light source One low-pressure mercury lamp
Wavelength 253,65 nm
Detector Two UV-enhanced photodiodes One UV-enhanced photodiode Two UV-enhanced photodiodes
Detection limit 0,003 ng Hg 0,001 ng Hg
Working range 0,03 ng to 30000 ng Hg 0,03 ng to 1500 ng Hg 0,01 ng to 1500 ng Hg
Typical precision < 1,5% @ 10-20000 ng Hg < 1,0% @ 10 ng Hg
Calibration Standard solutions and certified reference materials
Pre-concentration Up to 10 times
DMA-80 Wide Range DMA-80 Dual Cell DMA-80 Tri Cell
Mercury detection
Terminal 660 Touch-screen industrial grade controller
6,5” screen with 64.000 colors
VGA resolution 640x480 for sharp process graphic
5 USB ports for printer, keyboard, mouse, storage devices and other external peripherals
1 RS-232 port for analytical balance interface
1 LAN for network connection
Terminal 1660 Touch-screen industrial grade controller
12,1” screen with 64.000 colors
SVGA resolution 800x600 for sharp process graphic
5 USB ports for printer, keyboard, mouse, storage devices and other external peripherals
1 RS-232 port for analytical balance interface
1 LAN for network connection
PC (minimum requirements) CPU Pentium III 800
RAM 256 MB
20 MB free space on hard disk
1 USB port
1 CD-ROM reader
Windows 7, XP or Vista
Mercury detection
Dimensions 800 (w) x 420 (d) x 300 (h) mm
Weight 56 kg
Power supply 110-230 V, 50-60 Hz
Mercury detection
Direct gas analysis Injection block for sampled delivery and vacuum pump
Analysis time approximately 3 minutes per sample
Wide dynamic range (0,01 to 1500 μg/m3)
Indirect gas analysis By mercury sorbent traps
Mercury detection
Standard methods US EPA method 7473 (Mercury in solids and solutions by thermal decomposition, amalgamation, and atomic absorption spectrophotometry)
ASTM method D-6722-01 (Standard test method for total mercury in coal and coal combustion residues by direct combustion analysis)
ASTM method D-7623-10 (Standard test method for total mercury in crude oil using combustion-gold amalgamation and cold vapor atomic absorption method)
Operating software EasyCONTROL software is fully compliant with FDA regulations 21 CFR Part 11
www.milestonesrl.com Specifications are subject to change without notice.