0% found this document useful (0 votes)
16 views2 pages

B1027 - Lt48eq21li0x3h1141

The EZ-track Analog Profile Series utilizes magnetostrictive technology to measure linear position through a mechanical strain pulse. It offers various output configurations, including current, voltage, and differential outputs, with specifications for enhanced resolution and standard resolution models. The series features a diagnostic LED for operational status and is designed for flexibility in installation and application, including options for Class I, Division 2 environments.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
16 views2 pages

B1027 - Lt48eq21li0x3h1141

The EZ-track Analog Profile Series utilizes magnetostrictive technology to measure linear position through a mechanical strain pulse. It offers various output configurations, including current, voltage, and differential outputs, with specifications for enhanced resolution and standard resolution models. The series features a diagnostic LED for operational status and is designed for flexibility in installation and application, including options for Class I, Division 2 environments.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Linear Position Technology

EZ-track

Analog Profile Series


EZ-track LDT's profile style probes use speed timer measures the time difference
magnetostrictive technology by applying a between the applied strain pulse and the return
mechanical strain pulse to a magnetostrictive of the induced current pulse. This time,
waveguide that runs the length of the sensor. proportional to position is compared to the "zero"
When the strain pulse encounters a magnetic field and "span" positions established during the
produced by the slide or floating magnet calibration process to scale the output.
assembly, a current pulse is produced that is Once the position has been scaled accordingly, it
picked up by the electronic circuitry. A high is converted to a signal in the form of an analog
(voltage or current) output, quadrature pulse
Enhanced Resolution Analog Profile Series (Q21R/Q35R) Specifications:
output, or digital (PWM or start/stop) outputs.
Current: Voltage: Differential:
Output: 20 to 4 mA 0 to 10 V 0 to 10 V
4 to 20 mA 10 to 0 V 4 to 20 mA Low Profile Extrusion Housing:
≤ (voltage in - 4) ÷ 0.02 A The Q21 series is housed in low profile,
Load impedance: ≥ 1000 Ω environmentally sealed, anodized aluminum
(example: 10 VDC ≤ 300 Ω)
Q21R span: 40 to 180 in housings. The electronics and the sensing
Q35R span: 5 to 36 in element are incorporated into a housing that is

Linear Position Technology


Repeatability: +/-0.006% of full span or +/-0.002 in, whichever is greater less than 1 inch tall without the need for a can or
Resolution: 0.001 in internal (For span lengths < 65 in); 16 bit (For lengths > 65 in) head on the sensor to house the electronics
Non-linearity: +/-0.05% of stroke
Operating temperature: -4 to +158 °F (-20 to +70 °C) Diagnostic LED:
Null zone: 3.00 in The EZ-track Series utilizes a diagnostic LED that
enables the operator to understand the state of
Dead zone: 2.00 in
the sensor dependent upon the position of the
Operating voltage: 13.5-30 VDC
target magnet.
Current consumption: 120 mA at 15 VDC, 2.5 watts maximum
≤ 50 in 1 ms The LED flashes to indicate it is in AGC mode (Q21
51 to 100 in 2 ms
Response time: and Q35 series). This feature simplifies
101 to 150 in 3 ms
151 to 180 in 4 ms programming and troubleshooting, effectively
Green = Power is applied and magnet is present in the programmed range reducing setup and maintenance time.
Red = Fault, magnet is in the Null Zone, Dead Zone or lost
LED: Yellow = Magnet is out of the active programmed range, Various Analog Outputs
but still within the active stroke area Available Profile Style:
Electronics: IP67, IP68 optional The Q21 and Q35 series may be ordered in a
Protection rating: Rod housing: IP65 variety of outputs.
Agency approval: CE
Standard Resolution Analog Profile Series (Q21/Q35) Specifications: Although sensors may be ordered with any of the
Voltage: above outputs, the units may easily be changed in
+5 to -5 V the field to reverse the analog signal. Thus, one
0 to +10 V model can be used for two applications by
Current: -5 to +5 V
Output: 20 to 4 mA +10 to 0 V programming the “zero” and “span” appropriately.
4 to 20 mA 0 to +5 V
-10 to +10 V Automatic Gain Control:
+5 to 0 V The Automatic Gain Control (AGC) feature allows
+10 to -10 V
the EZ-track to sense a magnet other than the
≤ (voltage in - 4) ÷ 0.02 A
Load impedance: ≥ 1000 Ω (1500 for Ω +/-100) standard slide magnet and adjust to the magnetic
(example: 10 VDC ≤ 300 Ω)
field strength accordingly. With the ability to
Q21 span: 40 to 180 in
Q35 span: 5 to 36 in sense a standard floating magnet up to 3/8 inch
Repeatability: +/-0.01% of full span or +/-0.014 in, whichever is greater away, the user has greater mounting flexibility for
various applications.
Resolution: 0.014 in for stroke lengths less than 60 in; For lengths over 60 in: 12 bits
Non-linearity: +/-0.05% of stroke or +/-0.028 whichever is greater
FM Approved Installation
Accuracy: +/-0.1% of stroke or +/-0.050 whichever is greater (Class I, Division 2):
Operating temperature: -40 to +158 °F (-40 to +70 °C) The EZ-track Q21 unit can be ordered for use in a
Null zone: 3.00 in Class I, Division 2 environment. The unit utilizes a
Dead zone: 1.50 in Lock-Euro-G.
Operating voltage: 10-30 VDC
Current consumption: 100 mA (maximum)
50 in or less: 1 ms updates with 5 ms settling time
Response time: 50 in or greater: 2 ms updates with 4 ms settling time
Green = power is applied and magnet is present in the programmed range
Red = fault, magnet is in the null zone, dead zone or lost
LED: Yellow = magnet is out of the active programmed range,
but still within the active stroke area
Electronics: IP67, IP68 optional
Protection rating: Rod housing: IP65
Agency approval: CE, FM Class I, Div 2

Turck Inc. | 3000 Campus Drive, Minneapolis, MN 55441 | T +1 800 544 7769 | F +1 763 553 0708 | www.turck.com B1027 B17
Linear Position Technology
EZ-track

Analog Profile Series


Part Number Key: Analog Profile Series
A B C D E F G H I J
LT 40 E - Q21 R - LI 0 X3 - H1151 / S1661

A Type G Output Type


LT Linear Transducer Current Voltage Differential
0 4-20 mA 0 to 10 V 0 to 10 V ³⁾
B Measuring Span 1 20-4 mA 10 to 0 V 4 - 20 mA ³⁾
* Length of Measuring Span 2 -10 to 10 V ²⁾
3 10 to -10 V ²⁾
4 0 to 5 V ²⁾
C Housing
5 5 to 0 V ²⁾
E Inches 6 -5 to 5 V ²⁾
7 5 to -5 V ²⁾
D Housing Height 2⁾ Only available with 'Q21'/'Q35'.
3) Only available with 'Q21R'/'Q35R'.
Q21 21 mm
Q35 35 mm H Number of LEDs
X3 3 Diagnostic LEDs
E Resolution
(Blank) Standard Resolution I Type of Connection
R Enhanced Resolution H1141 4-pin M12 Eurofast Connector ²⁾
H1151 5-pin M12 Eurofast Connector ³⁾
F Output Configuration
LI Current J Specials
LU Voltage (Blank) IP67
LD Differential ¹⁾ S1661 IP68
1⁾ Analog differential ouput is the difference between two magnets.
Minimum distance = 2.5 inches
Note: In addition to the LDT, a typical system includes a magnet, mounting feet and cable (all sold separately).

Dimensions: Q21 Analog Profile Series Wiring Diagrams:


Q21R/Q35R Q21/Q35
5-pin Eurofast Connection 4-pin Eurofast Connection
BN
BN
BK
BK
BU
BU
WH
WH
GY

Mating Cordset: Mating Cordset:


RK 4.5T-*/S618 RK 4.4T-*/S618
* Length in meters.
Note: Self contained piston with magnet
permantly attached
Dimensions: Q35 Analog Profile Series

B18 B1027 Turck Inc. | 3000 Campus Drive, Minneapolis, MN 55441 | T +1 800 544 7769 | F +1 763 553 0708 | www.turck.com