The document is a manual for Siemens S7-1200 and S7-1500 communication systems, detailing safety warnings, proper usage, and legal information. It includes instructions for using OPC UA client programs, compact instructions, and error handling for communication processes. The manual emphasizes the importance of qualified personnel and adherence to safety protocols when operating these systems.

Uploaded by

Uhule Peter
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
344 views286 pages

Opc Ua

The document is a manual for Siemens S7-1200 and S7-1500 communication systems, detailing safety warnings, proper usage, and legal information. It includes instructions for using OPC UA client programs, compact instructions, and error handling for communication processes. The manual emphasizes the importance of qualified personnel and adherence to safety protocols when operating these systems.

Uploaded by

Uhule Peter
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 286

Communication (S7-1200, S7-

1500) 1

Communication (S7-1200, S7-


1500)

Manual

V20

11/2024
Legal information
Warning notice system

This manual contains notices you have to observe in order to ensure your personal safety, as
well as to prevent damage to property. The notices referring to your personal safety are
highlighted in the manual by a safety alert symbol, notices referring only to property damage
have no safety alert symbol. These notices shown below are graded according to the degree of
danger.

DANGER

indicates that death or severe personal injury will result if proper precautions are not taken.

WARNING

indicates that death or severe personal injury may result if proper precautions are not taken.

CAUTION

indicates that minor personal injury can result if proper precautions are not taken.

NOTICE

indicates that property damage can result if proper precautions are not taken.

If more than one degree of danger is present, the warning notice representing the highest
degree of danger will be used. A notice warning of injury to persons with a safety alert symbol
may also include a warning relating to property damage.

Qualified Personnel

The product/system described in this documentation may be operated only by personnel


qualified for the specific task in accordance with the relevant documentation, in particular its
warning notices and safety instructions. Qualified personnel are those who, based on their
training and experience, are capable of identifying risks and avoiding potential hazards when
working with these products/systems.

Proper use of Siemens products

Note the following:

WARNING

Siemens products may only be used for the applications described in the catalog and in the
relevant technical documentation. If products and components from other manufacturers are
used, these must be recommended or approved by Siemens. Proper transport, storage,
installation, assembly, commissioning, operation and maintenance are required to ensure
that the products operate safely and without any problems. The permissible ambient

2 Manual, 11/2024
conditions must be complied with. The information in the relevant documentation must be
observed.

Trademarks

All names identified by ® are registered trademarks of Siemens Aktiengesellschaft. The


remaining trademarks in this publication may be trademarks whose use by third parties for their
own purposes could violate the rights of the owner.

Disclaimer of Liability

We have reviewed the contents of this publication to ensure consistency with the hardware and
software described. Since variance cannot be precluded entirely, we cannot guarantee full
consistency. However, the information in this publication is reviewed regularly and any
necessary corrections are included in subsequent editions.

Siemens Aktiengesellschaft
Copyright © Siemens 2024.
Digital Industries
11/2024 Subject to change All rights reserved
Postfach 48 48
90026 NÜRNBERG
GERMANY

Manual, 11/2024 3
Table of content

1 Communication (S7-1200, S7-1500) 6


1.1 OPC UA (S7-1200, S7-1500) 6
1.1.1 Client instructions (S7-1500) 6
1.1.1.1 OPC UA instructions for client programs (S7-1500) 6
1.1.1.2 Compact instructions (S7-1500) 9
1.1.1.3 Preparing data exchange (S7-1500) 25
1.1.1.4 Data exchange (S7-1500) 80
1.1.1.5 Ending data exchange (S7-1500) 123
1.1.1.6 Diagnostics (S7-1500) 139
1.1.1.7 Methods (S7-1500) 155
1.1.1.8 System data types for OPC UA client instructions (S7-1500) 185
1.1.1.9 Error codes (S7-1500) 195
1.1.1.10 Example programs for OPC UA clients (S7-1500) 217
1.1.2 Server instructions (S7-1200, S7-1500) 275
1.1.2.1 Methods (S7-1200, S7-1500) 275
1.2 Communications processor (S7-1200, S7-1500) 286

4 Manual, 11/2024
Manual, 11/2024 5
Communication (S7-1200, S7-1500)
1
This section contains information on the following topics:

S7 communication (S7-1200, S7-1500)

Open User Communication (S7-1200, S7-1500)

OPC UA (S7-1200, S7-1500)

Web server (S7-1200, S7-1500)

Communications processor (S7-1200, S7-1500)

TeleService (S7-1200)

Failsafe HMI Mobile Panels (S7-1200, S7-1500)

1.1 OPC UA (S7-1200, S7-1500)

1.1.1 Client instructions (S7-1500)

1.1.1.1 OPC UA instructions for client programs (S7-1500)

Introduction
Based on program examples, the following sections are showing you how to use the OPC UA
instructions for client programs.
The program examples are based on a plant in which an S7-1500 CPU serves as server and
another S7-1500 CPU as client:

The server provides PLC tags for reading and writing as well as a server method.

The client accesses the values provided and calls the server method.

STEP 7 helps you in supplying the parameters of the instructions when you create a client
interface and use the connection parameter assignment for OPC UA. This means you will not
have to create many tags manually for supplying the parameters. To find out how to work
manually, read the example in the section on the "OPC_UA_TranslatePathList" instruction.
How to use the convenient parameter assignment for OPC UA is described in the following
sections for the OPC UA instructions.

Program examples in SCL


The program examples use the Structured Control Language (SCL) programming language.
The complete source code is available for each program example.

6 Manual, 11/2024
Standardized instructions according to PLCopen
The OPC UA instructions for clients have mostly been implemented according to the
specification "PLCopen OPC-UA-Client for IEC 61131-3".
Standardization makes it easier to port a user program to a controller of a different manufacturer
that also provides the OPC UA instructions according to the PLCopen specification.
If you already know the basic structures and processes of OPC UA clients, you can find your way
around more easily.

Many client instructions are working with lists


Many OPC UA client instructions process not only a value but lists.
This means the instruction "OPC_UA_NamespaceGetIndexList", for example, receives a list with
namespaces and returns a list with the indexes for these namespaces.

Even easier with compact instructions


As of TIA Portal V17, you can use compact instructions which are similar to the compact
instructions for Open User Communication. The compact instructions ensure that the
establishment of the connection or sessions required for the execution of the read/write method
is executed at the same time. The following instructions are available:

OPC_UA_ReadList_C: Set up session and read tags

OPC_UA_WriteList_C: Set up session and write tags

OPC_UA_MethodCall_C: Set up session and call method

Performance capability of a OPC UA server


OPC UA servers themselves provide information on their performance capability.
The figure below shows the address space of an S7 CPU of the type 1516-3 PN/DP.
In the node "MaxNodesPerRead" you specify, for example, how many PLC tags can be read
simultaneously with one call of the "OPC_UA_ReadList" instruction.
The high field limit of the array with which you can supply the "NodeHdls" parameter is limited
by the properties of the OPC UA client that is used (see technical specifications of the client).
The following limits apply across all client interfaces (i.e. across all lists):

1000 nodes for CPU 1510SP (F), CPU 1511 (C/F/T/TF), CPU 1512C, CPU 1512SP (F), CPU 1513
(F)

2000 nodes for CPU 1505 (S/SP/SP F/SP F/SP T/SP TF), CPU 1515 (F/T/TF), CPU 1515 SP PC
(F/T/TF), CPU 1516 (F/T/TF)

5000 nodes for CPU 1507S (F), CPU 1517 (F/T/TF), CPU 1518 (F)

Manual, 11/2024 7
The figure shows a section of the address space of an OPC UA server, shown with the "UaExpert"
from Unified Automation.

Error numbers
The error numbers for the instructions are divided up as follows:

If the error number starts with "16#B0" or "16#C0", it was assigned by Siemens, see Siemens

error codes.

Example: The following error numbers are general numbers that can basically occur for any

of the client instructions:

8 Manual, 11/2024
B080_C400 ClientNotEnabled Client disabled.

Enable the client in the TIA Portal.

B080_C500 ClientNotAvailable Error during initialization of the client

C080_C300 Simatic_OutOfResources Error at memory allocation or too many

instances of the instruction

If the error number starts with "16#80" it was assigned by the OPC Foundation see Error
codes of the OPC Foundation.

If the error number starts with "16#A0" it was assigned by PLCopen, see PLCopen error
codes.

You can also find a list with error numbers of the PLCopen in section 4 of the specification
"PLCopen OPC UA Client for IEC 61131-3". The specification is available from PLCopen.

See also
Number of client instructions that can be used simultaneously (S7-1500, S7-1500T)
Using OPC UA communication (S7-1200, S7-1500, S7-1500T)
Error codes (S7-1500)
Compact instructions (S7-1500)

1.1.1.2 Compact instructions (S7-1500)

1.1.1.2.1 OPC_UA_ReadList_C: Set up session and read tags (S7-1500)

On which CPUs can you use the "OPC_UA_ReadList_C" instruction?


The "OPC_UA_ReadList_C" instruction is contained in S7-1500 CPUs as of firmware version V2.8.

Description
The "OPC_UA_ReadList_C" instruction sets up a session with an OPC UA server and reads
specified values from its NodeSet.

Difference to the "OPC_UA_ReadList" instruction


The "OPC_UA_ReadList_C" instruction belongs to the so-called compact instructions in the OPC
UA client library, which is indicated by "_C" in the instruction name.
Like every compact instruction in the OPC UA client library, it is characterized by the fact that
only this one instruction must be parameterized and executed to fulfill its actual task as an OPC
UA client. The user does not have to call further instructions as required when using
"OPC_UA_ReadList" (for example, to establish a connection and determine the current indexes of
the namespaces in an OPC UA server).

Manual, 11/2024 9
Functional description
The "OPC_UA_ReadList_C" instruction works asynchronously. Processing extends over multiple
calls.
The mode of operation depends on the parameter "REQ":

Call without rising edge at REQ

If MaintainSession=TRUE, a session is set up if none already exists. If

MaintainSession=FALSE, an existing session is terminated if no job is active.

Call with rising edge at REQ

The job is activated: A session is set up, if one does not already exist, and the read process is

carried out. If MaintainSession=FALSE, the session is ended after the read operation; if

MaintainSession=TRUE, it is maintained.

The parameters "Busy" and "Done" indicate the status of the job.
The "Status" parameter can contain information about the current processing step, a warning or
an error:

As long as "Busy" has the value TRUE, "Status" provides information about the current

processing step.

When the job has been processed ("Done" has the value TRUE) and "Error" has the value

FALSE, it still makes sense to check the "Status" parameter. It may contain a warning.

When the job has been processed and "Error" has the value TRUE, "Status" contains the error

that has occurred.

See also: Difference between synchronous and asynchronous instructions

Parameter
The following table shows the parameters of the "OPC_UA_ReadList_C" instruction. Parameters
whose names are written in bold are mandatory parameters; they must be assigned to compile
the instruction successfully.

Parameter Declaration Data type Description

REQ Input Bool Control parameter Request


Activates the job on a positive edge:
Setting up a session, if one does not
already exist, and starting the
reading process

MaintainSession Input Bool Influences the OPC UA transport


session with the remote server:

10 Manual, 11/2024
TRUE: If a session does
not yet exist, the

instruction tries to set up

a session and maintain it.

FALSE: If a session exists

and no job is active, the


instruction terminates the

session.

Note: If "MaintainSession"
has the value FALSE and
"REQ" detects a rising edge,
a session is set up and a job
is activated. If
"MaintainSession" still has
the value FALSE after the job
is finished, the session is
terminated.

ServerEndpointUrl Input String[254] String with the address (URL)


of the OPC UA server
IPv4 addresses as well as
FQDN (Fully Qualified
Domain Names) are
permitted, provided you
have configured a DNS
server in the CPU properties.

SessionConnectInfo Input OPC_UA_SessionConnectInfo Session description


See:
OPC_UA_SessionConnectInfo

NamespaceUrisCount Input UInt Determines the number of


namespaces to be
considered from the array
"NamespaceUris".
If you assign the value 0 to
this parameter, the
"OPC_UA_ReadList_C"
instruction uses the size of
the array that was specified
using the "NamespaceUris"
InOut parameter.

NodeIDCount Input UInt Determines the number of


elements (nodes) to be

Manual, 11/2024 11
number to be read from the server.
If you assign the value 0 to this parameter,
the "OPC_UA_ReadList_C" instruction uses
the size of the array that was specified
using the "NodeIDs" InOut parameter.

Done Output Bool Status parameter with the following values:

0: Job not yet started or still being


processed.

1: Job completed without error. This


state is only displayed for one call.

Busy Output Bool Status parameter with the following values:

0: Job not yet started or already


completed.

1: Job not yet completed. A new job


with this instance cannot be started.

Error Output Bool Status parameter with the following values:

0: No error occurred.

1: Error occurred during processing. This

state is only displayed for one call.

Status Output DWord Return value or error information of the


"OPC_UA_ReadList_C" instruction, see
below

NamespaceUris InOut Variant Pointer to an array of the type STRING or


WSTRING.
Provided list of namespace URIs

NamespaceStatusList InOut Variant Pointer to an array of the type DWORD.


Status of the list with the resolved
namespaces

NamespaceIndexes InOut Variant Pointer to an array of the type UINT.


Cache into which the instruction writes the
namespace indexes when the session is set
up and which it uses again later when
reading the tags

12 Manual, 11/2024
Provided list of nodes to be read

NodeHdls InOut Variant Pointer to an array of the type DWORD.


Cache into which the "OPC_UA_ReadList_C"
instruction writes the NodeHandles when the
session is set up and which it uses again later when
reading the tags

NodeStatusList InOut Variant Pointer to an array of the type DWORD.


Storage location for the status list in which the
statuses of the read nodes are saved

TimeStamps InOut Variant Storage location for the time stamps of the nodes

Tag InOut Variant Structure with the suitable data types of the
requested tags
Storage location for node data

Status parameter
See: Status parameter
See also
Useful information about the OPC UA compact instructions (S7-1500)

1.1.1.2.2 OPC_UA_WriteList_C: Set up session and write tags (S7-1500)

On which CPUs can you use the "OPC_UA_WriteList_C" instruction?


The "OPC_UA_WriteList_C" instruction is contained in S7-1500 CPUs as of firmware version V2.8.

Description
The "OPC_UA_WriteList_C" instruction sets up a session with an OPC UA server and describes the
tags of this OPC UA server.

Difference to the "OPC_UA_WriteList" instruction


The "OPC_UA_WriteList_C" instruction belongs to the so-called compact instructions in the OPC
UA client library, which is indicated by "_C" in the instruction name.
Like every compact instruction in the OPC UA client library, it is characterized by the fact that
only this one instruction must be parameterized and executed to fulfill its actual task as an OPC
UA client. The user does not have to call further instructions as required when using
"OPC_UA_WriteList" (for example, to establish a connection and determine the current indexes
of the namespaces in an OPC UA server).

Functional description
The "OPC_UA_WriteList_C" instruction works asynchronously. Processing extends over multiple
calls.

Manual, 11/2024 13
The mode of operation depends on the parameter "REQ":

Call without rising edge at REQ

If MaintainSession=TRUE, a session is set up if none already exists. If

MaintainSession=FALSE, an existing session is terminated if no job is active.

Call with rising edge at REQ

The job is activated: A session is set up, if one does not already exist, and the write operation
is carried out. If MaintainSession=FALSE, the session is ended after the write operation; if

MaintainSession=TRUE, it is maintained.

The parameters "Busy" and "Done" indicate the status of the job.
The "Status" parameter can contain information about the current processing step, a warning or
an error:

As long as "Busy" has the value TRUE, "Status" provides information about the current
processing step.

When the job has been processed ("Done" has the value TRUE) and "Error" has the value
FALSE, it still makes sense to check the "Status" parameter. It may contain a warning.

When the job has been processed and "Error" has the value TRUE, "Status" contains the error
that has occurred.

See also: Difference between synchronous and asynchronous instructions

Parameter
The following table shows the parameters of the "OPC_UA_WriteList_C" instruction. Parameters
whose names are written in bold are mandatory parameters; they must be assigned to compile
the instruction successfully.

Parameter Declaration Data type Description

REQ Input Bool Control parameter Request


Activates the job on a positive edge:
Setting up a session, if one does not
already exist, and starting the writing
process

MaintainSession Input Bool Influences the OPC UA transport


session with the remote server:

TRUE: If a session does not yet

exist, the instruction tries to set

up a session and maintain it.

14 Manual, 11/2024
FALSE: If a session exists
and no job is active, the

instruction terminates the

session.

Note: If "MaintainSession"
has the value FALSE and
"REQ" detects a rising edge,
a session is set up and a job
is activated. If
"MaintainSession" still has
the value FALSE after the job
is finished, the session is
terminated.

ServerEndpointUrl Input String[254] String with the address (URL)


of the OPC UA server
IPv4 addresses as well as
FQDN (Fully Qualified
Domain Names) are
permitted, provided you
have configured a DNS
server in the CPU properties.

SessionConnectInfo Input OPC_UA_SessionConnectInfo Session description


See:
OPC_UA_SessionConnectInfo

NamespaceUrisCount Input UInt Determines the number of


namespaces to be
considered from the array
"NamespaceUris".
If you assign the value 0 to
this parameter, the
"OPC_UA_WriteList_C"
instruction uses the size of
the array that was specified
using the "NamespaceUris"
InOut parameter.

NodeIDCount Input UInt Determines the number of


elements (nodes) to be
considered in the array
"NodeIDs". This is the
number to be written in the
server.
If you assign the value 0 to
this parameter, the
"OPC_UA_WriteList_C"
instruction uses the size of

Manual, 11/2024 15
the array that was specified using the
"NodeIDs" InOut parameter.

Done Output Bool Status parameter with the following values:

0: Job not yet started or still being

processed.

1: Job completed without error. This

state is only displayed for one call.

Busy Output Bool Status parameter with the following values:

0: Job not yet started or already

completed.

1: Job not yet completed. A new job

with this instance cannot be started.

Error Output Bool Status parameter with the following values:

0: No error occurred.

1: Error occurred during processing. This

state is only displayed for one call.

Status Output DWord Return value or error information of the


"OPC_UA_WriteList_C" instruction, see
below

NamespaceUris InOut Variant Pointer to an array of the type STRING or


WSTRING.
Provided list of namespace URIs

NamespaceStatusList InOut Variant Pointer to an array of the type DWORD.


Status of the list with the resolved
namespaces

NamespaceIndexes InOut Variant Pointer to an array of the type UINT.


Cache into which the instruction writes the
namespace indexes when the session is set
up and which it uses again later when
writing the tags

NodeIds InOut Variant Pointer to an array with elements of the


type OPC_UA_NodeId
Provided list of nodes to be written

16 Manual, 11/2024
NodeHdls InOut Variant Pointer to an array of the type DWORD.
Cache into which the "OPC_UA_WriteList_C"
instruction writes the NodeHandles when the
session is set up and which it uses again later when
writing the tags

NodeStatusList InOut Variant Pointer to an array of the type DWORD.


Storage location for the status list in which the
statuses of the read nodes are saved

Tag InOut Variant Structure with the suitable data types of the
requested tags
Storage location for node data

Status parameter
See: Status parameter
See also
Useful information about the OPC UA compact instructions (S7-1500)

1.1.1.2.3 OPC_UA_MethodCall_C: Set up session and call method (S7-1500)

On which CPUs can you use the "OPC_UA_MethodCall_C" instruction?


The "OPC_UA_MethodCall_C" instruction is contained in S7-1500 CPUs as of firmware version
V2.8.

Description
The "OPC_UA_MethodCall_C" instruction sets up a session with an OPC UA server and calls a
method on this server.

Difference to the "OPC_UA_MethodCall" instruction


The "OPC_UA_MethodCall_C" instruction belongs to the so-called compact instructions in the
OPC UA client library, which is indicated by "_C" in the instruction name.
Like every compact instruction in the OPC UA client library, it is characterized by the fact that
only this one instruction must be parameterized and executed to fulfill its actual task as an OPC
UA client. The user does not have to call further instructions as required when using
"OPC_UA_MethodCall" (for example, to establish a connection and determine the current
indexes of the namespaces in an OPC UA server).

Functional description
The "OPC_UA_MethodCall_C" instruction works asynchronously. Processing extends over
multiple calls.
The mode of operation depends on the parameter "REQ":

Call without rising edge at REQ

Manual, 11/2024 17
If MaintainSession=TRUE, a session is set up if none already exists. If
MaintainSession=FALSE, an existing session is terminated if no job is active.

Call with rising edge at REQ

The job is activated: A session is set up, if one does not already exist, and the call of a

method is carried out. If MaintainSession=FALSE, the session is ended after the method call;
if MaintainSession=TRUE, it is maintained.

The parameters "Busy" and "Done" indicate the status of the job.
The "Status" parameter can contain information about the current processing step, a warning or
an error:

As long as "Busy" has the value TRUE, "Status" provides information about the current

processing step.

When the job has been processed ("Done" has the value TRUE) and "Error" has the value

FALSE, it still makes sense to check the "Status" parameter. It may contain a warning.

When the job has been processed and "Error" has the value TRUE, "Status" contains the error

that has occurred.

See also: Difference between synchronous and asynchronous instructions

Parameter
The following table shows the parameters of the "OPC_UA_MethodCall_C" instruction.
Parameters whose names are written in bold are mandatory parameters; they must be assigned
to compile the instruction successfully.

Parameter Declaration Data type Description

REQ Input Bool Control parameter Request


Activates the job on a positive edge:
Setting up a session, if one does not
already exist, and starting the
method call

18 Manual, 11/2024
Note: If "MaintainSession"
has the value FALSE and
"REQ" detects a rising edge,
a session is set up and a job
is activated. If
"MaintainSession" still has
the value FALSE after the job
is finished, the session is
terminated.

ServerEndpointUrl Input String[254] String with the address (URL)


of the OPC UA server
IPv4 addresses as well as
FQDN (Fully Qualified
Domain Names) are
permitted, provided you
have configured a DNS
server in the CPU properties.

SessionConnectInfo Input OPC_UA_SessionConnectInfo Session description


See:
OPC_UA_SessionConnectInfo

NamespaceUrisCount Input UInt Determines the number of


namespaces to be
considered from the array
"NamespaceUris".
If you assign the value 0 to
this parameter, the
"OPC_UA_MethodCall_C"
instruction uses the size of
the array that was specified
using the "NamespaceUris"
InOut parameter.

MethodHdlCount Input UInt Determines the number of


elements (method handles)
to be considered in the array
"MethodHdls".
If you assign the value 0 to
this parameter, the
"OPC_UA_MethodCall_C"
instruction uses the size of
the array that was specified
using the "MethodHdls"
InOut parameter.

MethodHdl Input DWord Handle for the method to be


called

Manual, 11/2024 19
Done Output Bool Status parameter with the following values:

0: Job not yet started or still being

processed.

1: Job completed without error. This

state is only displayed for one call.

Busy Output Bool Status parameter with the following values:

0: Job not yet started or already

completed.

1: Job not yet completed. A new job

with this instance cannot be started.

Error Output Bool Status parameter with the following values:

0: No error occurred.

1: Error occurred during processing. This

state is only displayed for one call.

Status Output DWord Return value or error information of the


"OPC_UA_MethodCall_C" instruction, see
below

NamespaceUris InOut Variant Pointer to an array of the type STRING or


WSTRING.
Provided list of namespace URIs

NamespaceStatusList InOut Variant Pointer to an array of the type DWORD.


Status of the list with the resolved
namespaces

NamespaceIndexes InOut Variant Pointer to an array of the type UINT.


Cache into which the instruction writes the
namespace indexes when the session is set
up and which it uses again later when the
method is called

ObjectNodeIDs InOut Variant Pointer to an array with elements of the


type OPC_UA_NodeId.
The array contains the node IDs (NodeIDs)
of the objects (folders) in which the
methods are located.

20 Manual, 11/2024
MethodNodeIDs InOut Variant Pointer to an array with elements of the type
OPC_UA_NodeId.
The array contains the node IDs (NodeIDs) of
the methods for which handles are requested
from the server.

MethodHdls InOut Variant Pointer to an array of the type DWORD.


Cache into which the "OPC_UA_MethodCall_C"
instruction writes the MethodHandles returned
by the OPC UA server when the session is set up
and which it uses again later when the method
is called

StatusList InOut Variant Pointer to an array of the type DWORD.


Storage location for the status list in which the
status of the individual methods is saved.

MethodResult InOut Variant Pointer to a tag of the type DWORD.


Error code (result) of the called server method.
This error code is provided by the user program
of the OPC UA server or by the system (e.g. if
input parameters are incorrect).

InputArguments InOut Variant Pointer to a tag with the PLC data type (UDT) or
STRUCT, the name, number, order and data type
of which correspond to the expected input
parameters.

OutputArguments InOut Variant Pointer to a tag with the PLC data type (UDT) or
STRUCT, the name, number, order and data type
of which correspond to the expected output
parameters.

Status parameter
See: Status parameter
See also
Useful information about the OPC UA compact instructions (S7-1500)

1.1.1.2.4 Status parameter (S7-1500)

Status parameter
The values of the Status parameter are based on OPC 30001 - UA Companion Specification for
IEC61131-3 Client FBs.
They are classified as follows:

Manual, 11/2024 21
16#38xx_xxxx: Information

16#78xx_xxxx: Warnings

16#B8xx_xxxx: Error

Error code Description


(16#...)

3800_0000 Job completed successfully

3800_0100 Connection to the OPC UA server successfully established

3800_0300 Connection to the OPC UA server successfully terminated

3870_0000 No job active, no connection established

3870_0100 Initial call for establishing a connection

3870_0200 A connection is currently being established

3870_0300 A connection is currently being terminated

3870_0400 A connection has been established and is being monitored. No ReadList


job is active.

3870_0500 The requested job is being processed.

3870_0600 The session could not be set up. The instruction waits 30 seconds before
trying to set up the session again.

7800_0000 The function was completed successfully. The NodeStatusList contains


additional information.

7800_0100 Connection to the OPC UA server successfully set up. The NodeStatusList
parameter (for OPC_UA_ReadList_C and OPC_UA_WriteList_C) or the
parameter StatusList (for OPC_UA_MethodCall_C) contains additional
information.

7870_0200 A connection is being set up The NamespaceStatusList parameter contains


supplementary information.

B880_0100 Error when executing an internal system function. The static tag
s_OPC_UA_Connect_Instance.Status contains the specific error code.

22 Manual, 11/2024
B880_0200 Error when executing an internal system function. The static tag
s_OPC_UA_ NamespaceGetIndexList_Instance.Status contains the specific
error code.

B880_0300 Error when executing an internal system function.

OPC_UA_ReadList_C: The static tag

s_OPC_UA_NodeGetHandleList_Instance.Status contains the specific

error code.

OPC_UA_WriteList_C: The static tag

s_OPC_UA_NodeGetHandleList_Instance.Status contains the specific


error code.

OPC_UA_MethodCall_C: The static tag


s_OPC_UA_MethodGetHandleList_Instance.Status contains the specific

error code.

B880_0400 Error when executing an internal system function.

OPC_UA_ReadList_C: The static tag s_OPC_UA_ReadList_Instance.Status

contains the specific error code.

OPC_UA_WriteList_C: The static tag

s_OPC_UA_WriteList_Instance.Status contains the specific error code.

OPC_UA_MethodCall_C: The static tag

s_OPC_UA_MethodCall_Instance.Status contains the specific error

code.

B880_0500 Error when executing an internal system function.

OPC_UA_ReadList_C: The static tag

s_OPC_UA_NodeReleaseHandleList_Instance.Status contains the


specific error code.

OPC_UA_WriteList_C: The static tag


s_OPC_UA_NodeReleaseHandleList_Instance.Status contains the

specific error code.

OPC_UA_MethodCall_C: The static tag

s_OPC_UA_MethodReleaseHandleList_Instance.Status contains the

specific error code.

Manual, 11/2024 23
B880_0600 Error when executing an internal system function. The static tag
s_OPC_UA_Disconnect_Instance.Status contains the specific error code.

B880_0700 Error when executing an internal system function. The static tag
s_OPC_UA_ConnectionGetStatus_Instance.Status contains the specific
error code.

1.1.1.2.5 Useful information about the OPC UA compact instructions (S7-1500)

Setting up and terminating sessions


If you want to set up a session with the OPC UA server with the properties that are specified in
the "SessionConnectInfo" input parameter, set the "MaintainSession" parameter to TRUE. The
compact instruction then calls the required instructions to establish and maintain the session. As
long as the "MaintainSession" parameter has the value TRUE, the compact instruction will
continue to maintain the session and you can initiate additional jobs. If you want to terminate
the session, set the "MaintainSession" parameter to FALSE.
If several jobs are to be executed, you save CPU resources by maintaining the session using the
"MaintainSession" parameter: Instead of setting up and terminating a session with the server for
each job, the session remains set up and the jobs are executed faster.
If an error occurs when setting up or terminating a session without the execution of a job being
requested, the "Error" output parameter is not set. This means you should monitor the "Status"
output parameter when setting "MaintainSession" to identify problems when setting up or
terminating a session.

Request a read or write operation or a method call


A job is activated with a rising edge at the "REQ" input parameter, regardless of the value of the
"MaintainSession" parameter.
If a session already exists ("MaintainSession" = TRUE), the read or write process or the method
call is started immediately. If a session does not already exist, the compact instruction tries to set
up one and then starts the read or write process or the method call. In case of an error, the
session is closed.

Monitor the status list with the error codes of the tags read
After several internally called instructions have been successfully completed, the compact
instruction checks the status list of the internal instruction.

If the status list is empty, the output parameter "Status" contains an information
(16#38xx_xxxx).

If the status list is not empty, the compact instruction checks each list element. If an error
code occurs, the check is stopped and the output parameter "Status" contains a warning

(16#78xx_xxxx). In this case you should check the static tag s_StatusList_CurrentElement of

the instance DB of the compact instruction. Its value is the number of the element in the
status list array that contains the first error code.

24 Manual, 11/2024
Interactions between the OPC UA compact instructions and the other OPC
UA instructions
The connection handles and node handles that were obtained from the OPC UA compact
instructions can also be used by the other OPC UA instructions. You can, for example, call the
"OPC UA-ReadList_C" instruction to get a connection handle and node handles. You can use this
connection handle, which is available to you as a static tag, and the node handles for calling the
"OPC_UA_WriteList" instruction; there is no need to call additional OPC UA instructions to set up
the connection and to obtain the node handles.
This concept is based on the fact that the handles do not come from the instruction but are
made available by the firmware of the CPU. Therefore, the OPC UA instructions can use these
handles together as long as they are available in the CPU.
You may not call the OPC UA instructions to terminate the data exchange using a connection
handle that comes from an OPC UA compact instruction. In the case of the compact instructions,
this leads to errors in processing the job and in closing the session. If you set up a session with a
compact instruction, this session must be closed by the same instance of the compact
instruction.
You must not set up a session with the "OPC_UA_Connect" instruction and use this session with
an OPC UA compact instruction.

Reconnect if the connection was interrupted


The compact instructions try to maintain the connection to the server as long as the
"MaintainSession" parameter has the value TRUE. The instructions check the connection as
follows: You monitor whether the "Error" parameter is set to TRUE when instructions are called
internally. If this is not the case, the compact instructions assume that the connection still exists.
If the error code of the internally called instruction indicates a connection or server problem that
requires the connection to be closed and reopened, the compact instruction does not display an
error. If a node handle is available, it first calls "OPC_UA_NodeReleaseHandleList". Then, it calls
"OPC_UA_Disconnect". After the connection has been terminated, the compact instruction tries
to re-establish the connection the next time it is called with "MaintainSesion" = TRUE.
If an error occurs without the execution of a job being requested via the "REQ" input, the "Error"
output parameter of the compact instruction is not set. This means you must monitor the
"Status" output parameter to identify difficulties in setting up a session.
If an error occurs while the compact application is trying to set up a session ("Status" has the
value 16#3870_0100 or 16#3870_0200) and the "MaintainSession" parameter has the value
TRUE, the compact instruction will try to establish the session again after a delay of 30 seconds.
The "Status" parameter has the value 16#3870_0600 as long as the delay is active. You can
cancel the delay by setting the "MaintainSession" parameter to FALSE. In this case, the
instruction immediately starts a new attempt to set up the session.

Monitoring output parameters for errors


If a job was started ("Busy"=TRUE) and then ends ("Busy"=FALSE) and neither "Done" nor "Error"
have the value TRUE, the job has failed due to an error in the instance of an internal instruction.
In this case, it is strongly recommended that you monitor the "Status" output parameter to see
whether it contains an error code that begins with 16#B8.

1.1.1.3 Preparing data exchange (S7-1500)

Manual, 11/2024 25
1.1.1.3.1 OPC_UA_Connect: Create connection

Validity
The following description of the "OPC_UA_Connect" instruction applies to S7-1500 CPUs with
firmware version V2.6 and higher.

Description
The "OPC_UA_Connect" instruction establishes a connection to an OPC UA server.
The following figure shows the icon of the instruction in the editor (FBD).

In the figure above, the parameters of the instruction are not supplied yet.
The instruction is used to prepare the data exchange between an OPC UA server and an OPC UA
client, see explanation for ① in the figure below:
The instruction returns a connection handle (a numerical reference) which uses the following
instructions to refer to the connection.

① Instructions for preparation of read and write operations

② Read and write instructions (call the instructions repeatedly depending on the
application)

③ Instructions for releasing resources after completed read or write operations

Parameters for "OPC_UA_Connect"

26 Manual, 11/2024
Parameters Declaration in Data Meaning
area type

REQ Input BOOL A rising edge 0 → 1 at the


parameter triggers execution of
the instruction.

ServerEndpointUrl InOut VARIANT Pointer to a tag of the type STRING


or WSTRING with the address
(URL) of the OPC UA server. IPv4
addresses as well as FQDN (Fully
Qualified Domain Names) are
permitted, provided you have
configured a DNS server in the
CPU properties.

SessionConnectInfo InOut VARIANT Pointer to the connection


description in a tag with the
system data type
"OPC_UA_SessionConnectInfo".

Timeout Input TIME Maximum time for the


establishment of the connection
in milliseconds.
The "Timeout" parameter defines
the service timeout for lower-level
OPC UA service requests that the
client is sending to the server.
Timeout values smaller than 100
ms or negative values are set to
100 ms, as smaller values are not
useful.

Done Output BOOL Execution status parameter:

0: Execution of the instruction

aborted, not yet complete or

not yet started

1: Execution of instruction

completed without errors

Busy Output BOOL Execution status parameter:

0: Instruction not being

executed

Manual, 11/2024 27
1: Instruction currently being executed

Error Output BOOL Error display

0: No error

1: An error has occurred. See "Status"

parameter.

Status Output DWORD Cause of the error, see "Error numbers for Status"
below.

ConnectionHdl Output DWORD Unique identifier for a connection established.


This handle is required by other OPC UA
instructions as an input parameter.

Error numbers for Status


The "Status" parameter provides information about errors that occurred during execution of the
instruction.
The following table explains the error codes:

Error code Name of the error Explanation


(hexadecimal
values)

0000_0000 OpcUa_Good Instruction finished successfully.

0070_0000 - First call without rising edge at REQ, which


means job execution is not started

0070_0100 - First call with start of job execution

0070_0200 - Subsequent call

8003_0000 OpcUa_BadOutOfMemory No memory available for the OPC UA


client.
As the OPC UA client and OPC UA server
share a memory area, you should reduce
the memory requirement of the server.
You have the following options:

Release fewer PLC tags for OPC UA.

Reduce the number of OPC UA clients

that are currently connected to the

28 Manual, 11/2024
server.

Set up fewer subscriptions.

General: Reduce the number of


registered OPC UA elements. Use

an OPC UA Server diagnostics tool

(such as UaExpert from Unified


Automation) to ensure that there

are no inactive sessions and

subscriptions. As countermeasure
you can select corresponding

timeouts (Subscription Timeout <=

Session Timeout) in the client.

8005_0000 OpcUa_BadCommunicationError Connection timeout.


Possible causes:

The server address

(ServerEndpointURL) is incorrect or

incomplete, or the server returns a


value that differs from the

addressed address. A difference

between the addressed and


returned address occurs in the

following cases:

- The server is located in another

subnet and is reached via NAT

(Network Address Translation)

- The server responds with its

name rather than its IP address

For an associated application

example, see: How do you


configure the OPC UA client of a

SIMATIC S7-1500 to establish a

Manual, 11/2024 29
The server does not accept the buffer size sent
by the client during connection establishment.

Remedies:

Check and correct the ServerEndpointURL. If

this error is caused by a difference between the


addressed and returned address, change the

server configuration so that the server

responds with the same ServerEndpointURL


with which it is addressed by the client. If the

behavior of the server cannot be changed,

enter the ServerEndpointURL in the


"ConnectInfo.ServerUri" tag

("SessionConnectInfo" parameter). The address

returned by the server is then overwritten by


this value. This value must also be in the server

certificate.

Check the permitted buffer size. The client of

the S7-1500 CPU provides 8192 bytes. The

server must accept this value.

800A_0000 OpcUa_BadTimeout A network timeout occurred.


Possible causes:

Connection to the OPC UA server is too slow.

The network load is too high.

The OPC UA server is not available.

The server might not accept the buffer size sent

by the client during connection establishment.

Remedies:

Check the URL of the OPC UA server.

Increase the timeout value of the instruction

OPC_UA_Connect.

Check the permitted buffer size. The client of

the S7-1500 CPU provides 8192 bytes. The

30 Manual, 11/2024
server must support this value.

803D_0000 OpcUa_BadNotSupported Possible causes:

The server address

(ServerEndpointURL) is

incorrect or incomplete.

Server does not support the

requested operation.

8054_0000 OpcUa_BadSecurityModeInsufficient The server sets higher security


requirements (security policy).
Possible remedy:

Use a higher security setting

for the connection to the


server.

8055_0000 OpcUa_BadSecurityPolicyRejected Server does not support requested


Security Policy or Transport Profile

8056_0000 BadTooManySessions The server has reached the


maximum number of sessions.

8081_0000 BadTcpNotEnoughResources The client's connection resources


required to establish the
connection are used up.
Possible remedy:

If the connection is established

and terminated in rapid

succession, the frequency must


be reduced.

B080_0100 Simatic_BadType_VariantInput1 Incorrect data type for parameter


"ServerEndpointUrl".

B080_0200 Simatic_BadType_VariantInput2 Incorrect data type for parameter


"SessionConnectInfo".

B080_2200 Simatic_BadValue_VariantInput2 Incorrect value of the tags


"SessionConnectInfo".

B080_C400 Simatic_ClientNotEnabled The OPC UA client is disabled.

Manual, 11/2024 31
Solution: Activate the OPC UA client in the
properties of the CPU (OPC UA > Client
area).

B080_C500 Simatic_NothingToDo Error during initialization of the client.

B080_C600 Simatic_ClientNotAvailable Error during initialization of the client.

C080_C300 Simatic_OutOfResources The maximum number of client instructions


that can be used at the same time has been
exceeded.
Possible remedy:

Reduce the number of client instructions


of the type running parallel, see:

Number of client instructions that can

be used simultaneously

For more error codes, see Error codes

Description of connection establishment and connection termination


If an error message indicates that there is a shortage of resources, you can determine the
currently allocated connection resources for the "OPC UA client/server communication" service
using the connection diagnostics. In it, you can see how many resources are still available.
The OPC UA client/server communication is based on the TCP protocol. Note that connection
resources are still tied up for a specific wait time during connection termination due to the TCP
protocol even though the connection has already been terminated. Before the productive
connection is established, a connection is set up for OPC UA to determine the endpoint for the
connection with the desired connection partner (Discovery).
Recommendation: If the number of required connections is close to the limit of available
connection resources, you should set up OPC UA connections over a longer period of time. If the
CPU OPC UA connections are set up in short-term intervals, you might experience a resource
shortage.
The following figures show how connections are established and terminated with the
corresponding wait times and the resultant resource allocation.
See also: Details about OPC UA client/server connections

This is how you use this instruction


The following sections show you how to use the instruction "OPC_UA_Connect" in a program
that exchanges data with an OPC UA server.

Requirements
The following description assumes that:

You have created a client interface, see "Creating client interfaces".

32 Manual, 11/2024
You have configured a connection to an OPC UA server in the properties of this client
interface.

Configuring secure connections


You can use the instruction "OPC_UA_Connect" to establish an unsecure connection to an OPC
UA server. But you should always use a secure connection.

How to use a client interface


1. In the "Project tree" area, select the CPU that acts as the client.

2. Add a new function block to the "Program blocks" folder.

In the example, the function block is called "ReadFromProductionline".

Used language: SCL.

3. Use drag-and-drop to move the instruction "OPC_UA_Connect" from the folder "Instructions

> Communication > OPC UA > OPC UA Client" to the editor.

4. Select the call as multi-instance.

STEP 7 creates an instance of this instruction and calls it "OPC_UA_Connect_Instance".

5. Click on the icon for "Start configuration" at the "OPC_UA_Connect_Instance" instruction.

STEP 7 opens the "Configuration" tab in the Inspector window.

6. Under "Select client interface for OPC UA connection" you select the client interface that you

want to use for the instruction.

In the example, the client interface is called "Productionline".

STEP 7 automatically supplies the parameters of the instruction with the values you have

configured for the client interface.

7. Click on "Block parameters" and assign tags manually to the remaining parameters (REQ,

Busy, Done, Error, Status).

Manual, 11/2024 33
STEP 7 adds the selected tags to the function call.

Calling the instruction


The following source code shows you how to use the instruction "OPC_UA_Connect" to establish
a connection to an OPC UA server.
You can find the complete program in the section "Example programs for OPC UA clients".
The example program is divided into multiple program sections (cases) by a CASE instruction.
The #State tag controls which program section is being executed.
In the first program section, a connection is established:

SCL

1: // case 1, connect to server


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_Connect_Instance(REQ := #Req,
ServerEndpointUrl :=
"Productionline_Configuration".Connection.ServerEndpointUrl,
SessionConnectInfo :=
"Productionline_Configuration".Connection.ConnectInfo,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
ConnectionHdl =>
"Productionline_Configuration".Connection.ConnectionHdl,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
#State := #State + 1;
END_IF;
IF #Error = TRUE THEN
// Did we get a connection handle?
IF "Productionline_Configuration".Connection.ConnectionHdl <> 0
THEN
// We have to release all resources in the server and disconnect
#State := 100;

34 Manual, 11/2024
//In case 100, to set REG of instruction "OPC_UA_Disconnect" to
FALSE
#Set_REQ_To_FALSE := TRUE;
ELSE
#State := 99;
END_IF;
#Mem_Status := #Status;
// set parameter REQ of OPC_UA_Connect to FALSE
#OPC_UA_Connect_Instance(ServerEndpointUrl :=
"Productionline_Configuration".Connection.ServerEndpointUrl,
SessionConnectInfo :=
"Productionline_Configuration".Connection.ConnectInfo,
REQ := FALSE,
ConnectionHdl =>
"Productionline_Configuration".Connection.ConnectionHdl,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout);
END_IF;

The example program calls the "OPC_UA_Connect" instruction for the following reasons:

To establish the connection to an OPC UA server.

If an error occurs, the REQ parameter is set to the value "FALSE".

Asynchronous execution
The instruction "OPC_UA_Connect" runs asynchronously to the user program and requires
multiple program cycles.
You can check the job status with the "Busy", "Done", "Error" and "Status" parameters.
Asynchronous program execution is described in the section "Difference between synchronous
and asynchronous instructions".

Explanation of the call of the instruction


This program part establishes a connection to the OPC UA server that you have entered during
the configuration of the client interface.
The tag "#State" contains the value "1" at the start of the program.
If the "OPC_UA_Connect" instruction is not yet executed, #Busy is FALSE, so that #Req is set to
TRUE. This starts the instruction. In the next cycle, #Req is FALSE.
If the output parameter "Done" is TRUE, a connection could be established. The success status
increases the value of the #State tag by one. This means the next program section (2:) is
executed in the next cycle, see OPC_UA_NamespaceGetIndexList: Read namespace indexes. The
success status also indicates the numerical reference for the established connection at the
"ConnectionHdl" output parameter.
If an error has occurred, the "Error" output parameter has the value TRUE.

Manual, 11/2024 35
If a connection handle is returned in the event of an error, resources must be released in the
server. The #State tag is assigned the value 100 for this.

If no connection handle is returned in the event of an error, the #State tag is assigned the
value 99.

The program sections 99 and 100 are reserved for error handling.
See also
OPC_UA_TranslatePathList: Determine current NodeIds (S7-1500)
Siemens error codes (S7-1500)
OPC UA instructions for client programs (S7-1500)
Program example for reading PLC tags (S7-1500)

1.1.1.3.2 Programming recommendation: Monitor connections. (S7-1500)

Recommendations for monitoring the connections


We recommend monitoring the connections created with the instruction "OPC_UA_Connect"
cyclically in order to be able to react specifically to connection aborts and to be able to establish
a new connection immediately in the event of an error.
The following description of the S7 user block for the OPC UA client of an S7-1500 CPU contains
a description of how to integrate connection monitoring.
S7 user block for the OPC UA client of a SIMATIC S7-1500
Changes as of CPU firmware version V2.8
With OPC UA, connection handles reference a connection. As of firmware version 2.8, you must
explicitly release the relevant connection handle in the event of a faulty or interrupted
connection by calling the "OPC_UA_Disconnect" instruction. It cannot be used until the
connection handle is released; it is invalid.
After the release of the connection handle, the CPU can reuse it for a new connection
(OPC_UA_Connect).
See also
OPC_UA_ConnectionGetStatus: Read connection status (S7-1500)

1.1.1.3.3 OPC_UA_NamespaceGetIndexList: Read namespace indexes (S7-1500)

Validity
The following description of the "OPC_UA_NamespaceGetIndexList" instruction applies to S7-
1500 CPUs with firmware version V2.6 and higher.

Description
You use the "OPC_UA_NamespaceGetIndexList" instruction to request the current indexes of the
namespaces in an OPC UA server.
The following figure shows the icon of the instruction in the editor (FBD).

36 Manual, 11/2024
In the figure above, the parameters of the instruction are not supplied yet.
The instruction "OPC_UA_NamespaceGetIndexList" is used to prepare the data exchange with an
OPC UA server, see ① in the figure below.
To read or write a PLC tag or to call a method, you must know the index of the namespace in
which the PLC tag is located. The index is a part of the address (NodeId) of this PLC tag in the
address space of the OPC UA server.
The instruction returns a list with the indices for the namespaces of the OPC UA server.
This list is necessary to request the NodeIDs that can be used to send the read and write jobs
with the "OPC_UA_NodeGetHandleList" instruction.

① Instructions for preparation of read and write operations

② Read and write instructions

③ Instructions for releasing resources after completed read or write operations

Parameters for "OPC_UA_NamespaceGetIndexList"


The parameters of the instruction "OPC_UA_NamespaceGetIndexList"

Parameters Declaration Data Meaning


in area type

Manual, 11/2024 37
REQ Input BOOL A rising edge 0 → 1 at the parameter
triggers execution of the instruction.

ConnectionHdl Input DWORD Unique identifier for a connection


established.
You get the handle from the instruction
OPC_UA_Connect: Create connection.

NamespaceUrisCount Input UINT Number of namespaces in the


NamespaceUris parameter

NamespaceUris InOut VARIANT Pointer to an array of the type STRING or


WSTRING.
The array contains the URIs of the
individual namespaces whose indexes are
to be requested.

Timeout Input TIME Maximum time for execution of the


instruction in milliseconds.
See also the explanation for this
parameter in OPC_UA_Connect: Create
connection.

StatusList InOut VARIANT Pointer to an array of the type DWORD


(optional).
The array contains the error codes for the
individual namespaces.
For each namespace, the system specifies
whether or not a corresponding index
could be found.

NamespaceIndexes InOut VARIANT Pointer to an array of the type UINT.


The array contains the indexes of the
individual namespaces that have been
requested from the OPC UA server.

Done Output BOOL Status of execution:

0: Execution of the instruction

aborted, not yet complete or not yet


started

1: Execution of instruction completed


without errors

Busy Output BOOL Execution status parameter:

38 Manual, 11/2024
1: Instruction currently being executed

Error Output BOOL Error display

0: No error

1: An error has occurred. See "Status" parameter.

Status Output DWORD Cause of the error, see "Error numbers for Status" below

Error numbers for Status


The "Status" parameter provides information about errors that occurred during execution of the
instruction.
The following table shows a summary of error codes for this instruction:

Error code Name of the error Explanation


(hexadecimal
values)

0000_0000 OpcUa_Good Instruction finished


successfully.

0070_0000 - First call without rising


edge at REQ, which
means job execution is
not started

0070_0100 - First call with start of job


execution

0070_0200 - Subsequent call

Manual, 11/2024 39
are currently connected to the

server.

Set up fewer subscriptions.

8009_0000 OpcUa_BadUnknownResponse Server does not respond with the


expected number of namespace array
elements

800A_0000 OpcUa_BadTimeout A network timeout occurred.


Possible causes:

Connection to the OPC UA server

is too slow (insufficient capacity)

The network load is too high.

The OPC UA server is not available.

Possible remedy:

Check the URL of the OPC UA

server

Increase the timeout setting

(higher value for the Timeout


parameter of the function block

OPC_UA_Connect).

800D_0000 OpcUa_BadServerNotConnected The server is not connected or the


connection handle is incorrect or
invalid.

800F_0000 OpcUa_BadNothingToDo NamespaceUrisCount is 0

8010_0000 OpcUa_BadTooManyOperations Number of


"OPC_UA_NamespaceGetIndexList"
instructions that can be called at the
same time per connection has been
exceeded (> 1), see:
Number of client instructions that can
be used simultaneously

809E_0000 OpcUa_BadDataUnavailable The indexes of the namespaces are


not currently available.

80AE_0000 BadConnectionClosed The connection with the


corresponding ConnectionHdl is in

40 Manual, 11/2024
"ShutDown" status (connection
terminated). The
connection/session could not
be "reactivated" automatically.
Possible cause: Session deleted
on the server, e.g. due to
restart or timeout).
In this case, you must explicitly
close the connection with the
instruction
"OPC_UA_Disconnect" and
release the connection
resources again. In your user
program, you must reset the
ConnectionHdl that has
become invalid for this
connection.
Then you have to establish a
new connection to the server
(see instruction
"OPC_UA_Connect").

80AF_0000 BadInvalidState The connection with the


corresponding ConnectionHdl
is has the "ConnectinError"
status (temporary connection
error, connection interrupted).
The CPU tries to "reactivate" the
connection. If this does not
succeed in the set timeout
interval (OPC UA Session
Timeout), the connection goes
into the "Shutdown" state.
Requirements for the state
transition: The CPU could reach
the OPC UA server to check
whether or not the session is
still active.

A000_0105 PLCopenUA_Bad_ConnectionInvalidHdl The connection handle


(ConnectionHdl) is invalid /
unknown.
See
OPC_UA_ConnectionGetStatus:
Read connection status

B080_0100 Simatic_BadType_VariantInput1 Incorrect data type for


parameter "NamenspaceUris".

B080_0200 Simatic_BadType_VariantInput2 Incorrect data type for


parameter "StatusList".

Manual, 11/2024 41
B080_0300 Simatic_BadType_VariantInput3 Incorrect data type for parameter
"NamenspaceIndexes".

B080_1100 Simatic_ArrayElements_TooMany NamespaceUrisCount >


MAX_ELEMENTS_NAMESPACES

B080_3100 BadNumElements_VariantInput1 NamespaceUrisCount > Number of


array elements of the
"NamespaceUris" parameter.

B080_3200 BadNumElements_VariantInput2 NamespaceUrisCount > Number of


array elements of the "StatusList"
parameter.

B080_3300 BadNumElements_VariantInput3 NamespaceUrisCount > Number of


array elements of the
"NamespaceIndexes" parameter.

B080_C500 Simatic_NothingToDo Nothing to do: The instruction is


using a list that contains no elements
(namespaces).

C080_C300 Simatic_InsufficientResources The maximum number of client


instructions that can be used at the
same time has been exceeded.
Possible remedy:

Reduce the number of client

instructions of the type running


parallel, see: Number of client

instructions that can be used

simultaneously

For more error codes, see Error codes.

Error numbers for "StatusList"


The parameter contains an error code for each individual namespace.
The following table explains the error codes:

42 Manual, 11/2024
"NamespaceIndexes" parameter is pointing.

806F_0000 OpcUA_BadNoMatch The namespace is not found.

For more error codes, see Error codes.

This is how you use this instruction


Based on a program example, this section shows you how to use the instruction
"OPC_UA_NamespaceGetIndexList" in a program that exchanges data with an OPC UA server.

Requirements
The following description assumes that:

You have created a client interface, see "Creating client interfaces".

You have configured a connection to an OPC UA server in the properties of this client

interface, see "Creating and configuring connections".

In addition, the following requirement must be met for the instruction


"OPC_UA_NamespaceGetIndexList":

A handle for connection to an OPC UA server is available.

You get the connection handle by calling the instruction OPC_UA_Connect: Create

connection.

Function of the instruction


For the exchange of data, you require the indexes of the namespaces that contain the tags that
you want to read or write using your program.
You also need the current indexes of the namespaces that contain the methods for calling
methods.
With an OPC UA server, the assignment, according to the OPC UA specification, between the
namespace and associated index is not fixed and can change, for example, if new namespaces
are added or namespaces are omitted.
You therefore need to request the current indexes from the OPC UA server before you get the
node handle using the instruction OPC_UA_NodeGetHandleList. You do this with the instruction
"OPC_UA_NamespaceGetIndexList".
What information does the instruction return?
The instruction returns the following information:

A list of the indexes for the individual namespaces ("NamespaceIndexes" parameter). The
order of the indexes corresponds to the order of the namespaces in the "NamespaceUris"

parameter.

A list of error messages ("StatusList" parameter).

Manual, 11/2024 43
Each error message in this list relates to the corresponding namespace in the
"NamespaceUris" parameter.

For each individual namespace, you can to check whether the index for that namespace can
be successfully returned.

Determining namespaces and their indexes with UaExpert


To use the instruction, the namespace URI (Uniform Resource Indentifier) must be known. You
can determine namespace URIs and namespace indexes with UaExpert, as the following
example shows:

How to use a client interface


1. In the "Project tree" area, select the CPU that acts as the client.

2. Select the function block that is to contain the client instruction in the "Program blocks"

folder.

In the example, the function block is called "ReadFromProductionline".

Selected language: SCL

3. Use drag-and-drop to move the instruction "OPC_UA_NamespaceGetIndexList" from the


folder "Instructions > Communication > OPC UA > OPC UA Client" to the editor.

4. Select the call as multi-instance.

STEP 7 creates an instance of this instruction and calls it

"OPC_UA_NamespaceGetIndexList_Instance".

5. Click on the icon for "Start configuration" at the "OPC_UA_NamespaceGetIndexList_Instance"

instruction.

STEP 7 opens the "Configuration" tab in the Inspector window.

6. Under "Select client interface for OPC UA interface" you select the client interface that you

want to use for the instruction.

In the example, the client interface is named "Productionline", see "Creating client

interfaces".

44 Manual, 11/2024
STEP 7 now automatically supplies the parameters of the instruction with the values you
have configured for the client interface.

7. Click on "Block parameters" and assign tags manually to the remaining parameters REQ,
Busy, Done, Error, Status.

STEP 7 adds the selected tag to the function call.

Calling the instruction


The following source code shows you how to use the instruction
"OPC_UA_NamespaceGetIndexList" to request the indexes for the namespaces that currently
used by the OPC UA server.
You can find the complete program in the section "Program example for reading PLC tags".
The example program is divided into multiple sections (cases) by a CASE instruction.
In the second program section, the indexes of the namespaces are requested:

SCL

2: // case 2, get index for namespace


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_NamespaceGetIndexList_Instance(NamespaceUris :=
"Productionline_Configuration".Namespaces.NamespaceURIs,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NamespaceIndexes :=
"Productionline_Configuration".Namespaces.ServerNamespaceIndexes,
StatusList :=
"Productionline_Configuration".Namespaces.NamespaceStatusList,
NamespaceUrisCount :=
"Productionline_Configuration".Namespaces.NamespaceCount,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
REQ := #Req,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);

Manual, 11/2024 45
IF #Done = TRUE THEN
IF
"Productionline_Configuration".Namespaces.NamespaceStatusList[0]
= 0 THEN
#State := #State + 1;
ELSE
#State := 100;
#Mem_Status := #Status;
#Output_Error_Message := WString#'Error at
NamespaceGetIndexList';
END_IF;
END_IF;
IF #Error = TRUE THEN
#State := 100;
//In case 100, to set REG of instruction "OPC_UA_Disconnect"
to FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#OPC_UA_NamespaceGetIndexList_Instance(NamespaceUris :=
"Productionline_Configuration".Namespaces.NamespaceURIs,
StatusList :=
"Productionline_Configuration".Namespaces.NamespaceStatusList,
NamespaceIndexes :=
"Productionline_Configuration".Namespaces.ServerNamespaceIndexes,
REQ := FALSE);
END_IF;

The example program calls the "OPC_UA_NamespaceGetIndexList" instruction for the following
reasons:

To request the index for a namespace.

If an error occurs, the REQ parameter is set to the value FALSE.

Asynchronous execution
The instruction "OPC_UA_NamespaceGetIndexList" runs asynchronously to the user program and
requires multiple program cycles.
You can check the job status with the "Busy", "Done", "Error" and "Status" parameters.
Asynchronous program execution is described in the section "Difference between synchronous
and asynchronous instructions".

Explanation of the call of the instruction

46 Manual, 11/2024
The figure above shows case 2. This part of the program requests the indexes for the
namespaces.
If the #State tag is 2, then case 2 is executed.
If the "OPC_UA_NamespaceGetIndexList" instruction is not yet executed, #Busy is FALSE an the
"#Req" tag is set to TRUE. This starts the instruction. In the next cycle, #Req is FALSE.
If the output parameter "Error" is TRUE, an error occurred during execution of the instruction.
This sets the #State tag to the value 100. This case is reserved for troubleshooting.
If the output parameter "Done" is TRUE, the instruction was executed successfully. The success
status increases the value of the "#State" tag by one. This means the next program section - case
3 (get handles for read access and write access) - is executed in the next cycle.
Case 3 is described in OPC_UA_NodeGetHandleList: Get handles for read and write access.

Note
Execution of the instruction
It is possible that the instruction is successfully executed ("Error" parameter not set,
"Done" parameter set) but no index can be returned for a specific namespace.
Therefore, there is a check in the example to determine whether an index has been
found for the namespace to be queried. If an index is found, the first element of
the array to which the "StatusList" parameter is pointing contains the value 0.

See also
OPC_UA_TranslatePathList: Determine current NodeIds (S7-1500)

1.1.1.3.4 OPC_UA_NodeGetHandleList: Get handles for read and write access (S7-1500)

Validity
The following description of the "OPC_UA_NodeGetHandleList" instruction applies to S7-1500
CPUs with firmware version V2.6 and higher.

Description
You use the "OPC_UA_NodeGetHandleList" instruction to register PLC tags on an OPC UA server.
The following figure shows the icon of the instruction in the editor (FBD).

Manual, 11/2024 47
In the figure above, the parameters of the instruction are not supplied yet.
The instruction "OPC_UA_NodeGetHandleList" is used to prepare the data exchange with an OPC
UA server, see ① in the figure below:
You use this instruction to register PLC tags on the server that you want to read or write.
This step optimizes later access with the instructions "OPC_UA_ReadList" and
"OPC_UA_WriteList".
The instruction returns a list with numerical references (handles) for the registered PLC tags.

① Instructions for preparation of read and write operations

② Read and write instructions

③ Instructions for releasing resources after completed read or write operations

Parameters for "OPC_UA_NodeGetHandleList"


The parameters of the instruction "OPC_UA_NodeGetHandleList"

Parameters Declaration Data Meaning


in area type

48 Manual, 11/2024
REQ Input BOOL A rising edge 0 → 1 at the parameter
triggers execution of the instruction.

ConnectionHdl Input DWORD Unique identifier for a connection


established.
You get the handle from the instruction
OPC_UA_Connect: Create connection.

NodeIDCount Input UINT Number of elements in the NodeIDs


parameter

NodeIDs InOut VARIANT Pointer to an array with elements of the


type OPC_UA_NodeId.
The array contains the NodeIds of the
tags for which the OPC UA server is to
provide numeric references (handles)
(see "Function of the block" above).

Timeout Input TIME Maximum time for execution of the


instruction in milliseconds.
See also the explanation for this
parameter inOPC_UA_Connect: Create
connection.

NamespaceIndexCount Input UINT Number of elements in the


"NamespaceIndexes" parameter.

NamespaceIndexes InOut VARIANT Pointer to an array of the type UINT.


This parameter is not required if there are
no elements in the
NamespaceIndexCount parameter
(NamespaceIndexCount = 0).
The array is used to assign new indexes to
the namespace indexes in the NodeIDs
parameter.
Example:
If there is a value of 10 in
NamespaceIndexes[4], all NodeIDs in the
"NodeIDs" parameter that previously had
the namespace index 4 are assigned the
namespace index 10.

NodeStatusList InOut VARIANT Pointer to an array of the type DWORD.


The array contains the error codes for the
NodeIds of the individual tags; see "Error
numbers for NodeStatusList" below.
It is specified whether a handle could be
assigned to each NodeId.

Manual, 11/2024 49
It is possible that the function block was successfully
executed (Error parameter not set) but no handle
could be found for a specific NodeId (tag).
A NodeId consists of a namespace index, a tag name
(identifier) and an identifier type. See
OPC_UA_NodeID.

NodeHdls InOut VARIANT Pointer to an array of the type DWORD.


The array contains the handles of the individual
NodeIds that have been requested from the OPC UA
server (see "Function of the block" above).

Done Output BOOL Status of execution:

0: Execution of the instruction aborted, not yet

complete or not yet started

1: Execution of instruction completed without

errors

Busy Output BOOL Execution status parameter:

0: Instruction not being executed

1: Instruction currently being executed

Error Output BOOL Error display

0: No error

1: An error has occurred. See "Status" parameter.

Status Output DWORD Cause of the error, see "Error numbers for Status"
below

Error numbers for Status


The "Status" parameter provides information about errors that occurred during execution of the
instruction.
The following table shows a summary of error codes for this instruction:

Error code Name of the error Explanation


(hexadecimal
values)

0000_0000 OpcUa_Good Instruction finished successfully.

50 Manual, 11/2024
0070_0000 - First call without rising edge at REQ,
which means job execution is not
started

0070_0100 - First call with start of job execution

0070_0200 - Subsequent call

8003_0000 OpcUa_BadOutOfMemory No memory available for the OPC UA


client.
As the OPC UA client and OPC UA server
share a memory area, you should
reduce the memory requirement of the
server.
You have the following options:

Release fewer PLC tags for OPC UA.

Reduce the number of OPC UA


clients that are currently connected

to the server.

Set up fewer subscriptions.

8009_0000 OpcUa_BadUnknownResponse The server has sent has response that


could not be recognized.

800A_0000 OpcUa_BadTimeout A network timeout occurred.


Possible causes:

Connection to the OPC UA server is


too slow (insufficient capacity)

The network load is too high.

The OPC UA server is not available.

Possible remedy:

Check the URL of the OPC UA server

Increase the timeout setting (higher

value for the Timeout parameter of


the function block

OPC_UA_Connect).

Manual, 11/2024 51
800D_0000 OpcUa_BadServerNotConnected The server is not connected or the
connection handle is incorrect or
invalid.

8010_0000 OpcUa_BadTooManyOperations Number of


"OPC_UA_NodeGetHandleList"
instructions that can be called at the
same time per connection has been
exceeded (> 1), see: Number of client
instructions that can be used
simultaneously

8033_0000 OpcUa_BadNodeIdInvalid The syntax of the node is invalid.

8034_0000 OpcUa_BadNodeIdUnknown The ID of the node (NodeId) refers to


a node that does not exist in the
address space of the server.

80AE_0000 BadConnectionClosed The connection with the


corresponding ConnectionHdl is in
"ShutDown" status (connection
terminated). The connection/session
could not be "reactivated"
automatically. Possible cause: Session
deleted on the server, e.g. due to
restart or timeout).
In this case, you must explicitly close
the connection with the instruction
"OPC_UA_Disconnect" and release the
connection resources again. In your
user program, you must reset the
ConnectionHdl that has become
invalid for this connection.
Then you have to establish a new
connection to the server (see
instruction "OPC_UA_Connect").

80AF_0000 BadInvalidState The connection with the


corresponding ConnectionHdl is has
the "ConnectinError" status
(temporary connection error,
connection interrupted). The CPU tries
to "reactivate" the connection. If this
does not succeed in the set timeout
interval (OPC UA Session Timeout),
the connection goes into the
"Shutdown" state. Requirements for
the state transition: The CPU could
reach the OPC UA server to check
whether or not the session is still
active.

52 Manual, 11/2024
B080_0100 Simatic_BadType_VariantInput1 Incorrect data type for parameter
"NodeIDs".

B080_0200 Simatic_BadType_VariantInput2 Incorrect data type for parameter


"NamenspaceIndexes".

B080_0300 Simatic_BadType_VariantInput3 Incorrect data type for parameter


"NodeStatusList".

B080_0400 Simatic_BadType_VariantInput4 Incorrect data type for parameter


"NodeHdls".

B080_1100 Simatic_ArrayElements_TooMany NodeIDCount >


MAX_ELEMENTS_NODELIST

B080_3100 BadNumElements_VariantInput1 NodeIDCount > Number of array


elements of the "NodeIDs" parameter.

B080_3200 BadNumElements_VariantInput2 NamespaceIndexCount > Number of


array elements of the
"NamespaceIndexes" parameter.

B080_3300 BadNumElements_VariantInput3 NodeIDCount > Number of array


elements of the "NodeStatusList"
parameter.

B080_3400 BadNumElements_VariantInput4 NodeIDCount > Number of array


elements of the "NodeHdls"
parameter.

B080_C400 Simatic_ClientNotEnabled The OPC UA client is disabled.

B080_C500 Simatic_NothingToDo Nothing to do: The instruction is


using a list that contains no
elements.

Manual, 11/2024 53
C080_C300 Simatic_OutOfResources The maximum number of client instructions
that can be used at the same time has been
exceeded.
Possible remedy:

Reduce the number of client instructions


of the type running parallel, see: Number

of client instructions that can be used

simultaneously

For more error codes, see Error codes.

Error numbers for "NodeStatusList"


The "NodeStatusList" parameter contains an error code for each individual NodeId (tag).
The following table explains the error codes:

Error code Name of the error Explanation


(hexadecimal
values)

0000_0000 OpcUa_Good The PLC tag (NodeId) was found.


The Handle of the tags was entered
in the Array to which the
"NodeHdls" parameter is pointing.

8033_0000 OpcUa_BadNodeIdInvalid The syntax of the NodeId is


incorrect.

8034_0000 OpcUa_BadNodeIdUnknown The NodeId refers to a node (tag)


that does not exist on the OPC UA
server.

A000_0309 PLCopenUA_Bad_OutOfHandles The NodeId was not registered


because the maximum number of
nodes
(PLCOPEN_MAXREGISTEREDNODES)
was reached.

For more error codes, see Error codes.

This is how you use this instruction


Based on a program example, this section shows you how to use the instruction
"OPC_UA_NodeGetHandleList" in a program that exchanges data with an OPC UA server.

54 Manual, 11/2024
The following description assumes that:

You have created a client interface, see "Creating client interfaces".

You have configured a connection to an OPC UA server in the properties of this client

interface, see "Creating and configuring connections".

In addition, the following requirements must be met for the instruction


"OPC_UA_NodeGetHandleList":

A handle for connection to an OPC UA server is available.

You get the connection handle from the instruction OPC_UA_Connect: Create connection.

Indexes of the namespaces in which the tags that you want to read or write with the client

are located.

You get the indexes from the instruction OPC_UA_NamespaceGetIndexList: Read namespace

indexes.

Function of the instruction


To optimize access to tags, OPC UA offers the "RegisterNodes" service for repeated accesses.
Servers can use this service to prepare optimized access to tags. The
"OPC_UA_NodeGetHandleList" instruction implicitly calls this service to prepare the server for
optimized access ("Registered Read/Write" in OPC UA language).
This is how you obtain numerical references (handles) from the OPC UA server through the call
of the "OPC_UA_NodeGetHandleList" instruction. You use these handles with the
"OPC_UA_ReadList" or "OPC_UA_WriteList" instructions, which correspond to an optimized access
with "Registered Read/Write".
What information is required?
The instruction requires the following information to request the numeric references (handles):

A list of the tags that are to be read or set ("NodeIDs" parameter, see system data type

"OPC_UA_NodeId").

This list contains the following information for each tag:

- Index of the namespace in which the tag is located.

- Tag identifier (tag name).

- Type of identifier

What information does the instruction return?


The instruction returns the following information:

A list of the handles for the tags ("NodeHdls").

The order of the handles corresponds to the order of the tags in the NodeIDs parameter.

A list of error messages ("NodeStatusList" parameter).

Manual, 11/2024 55
Each error message in this list relates to the corresponding tag in the NodeIDs parameter.

For each individual tag, you need to check whether the OPC UA server was able to return a

handle.

How to use a client interface


1. In the "Project tree" area, select the CPU that acts as the client.

2. Select the function block that is to contain the client instruction in the "Program blocks"

folder.

In the example, the function block is called "ReadFromProductionline".

Selected language: SCL.

3. Use drag-and-drop to move the instruction "OPC_UA_NodeGetHandleList" from the folder


"Instructions > Communication > OPC UA > OPC UA Client" to the editor.

4. Select the call as multi-instance.

STEP 7 creates an instance of this instruction and calls it

"OPC_UA_NodeGetHandleList_Instance".

5. Click on the icon for "Start configuration" at the "OPC_UA_NodeGetHandleList_Instance"

instruction.

STEP 7 opens the "Configuration" tab in the Inspector window.

6. Under "Select client interface for OPC UA interface" you select the client interface that you

want to use for the instruction.

In the example, the client interface "Productionline" is selected, which was created for the

example plant.

7. Click "Data access" and select a read list.

In the example: Read list "ReadListProduct".

STEP 7 now automatically supplies the parameters of the instruction with the values you

have configured for the client interface.

8. Click on "Block parameters" and assign tags manually to the remaining parameters REQ,

Busy, Done, Error, Status.

STEP 7 adds the selected tag to the function call.

Calling the instruction (initial call)

56 Manual, 11/2024
You can find the complete program in the section "Program example for reading PLC tags".
The program example uses the read list "ReadListProduct", which contains the following PLC
tags:

NewProduct

ProductNumber

The program receives numerical references (handles) from the server for these tags.
The example program is divided into multiple sections (cases) by a CASE instruction.
In the third program section, the handles of the nodes (PLC tags) that are to be read or written
are requested:

SCL

3: // case 3, get handles for nodes


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_NodeGetHandleList_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeIDCount :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeCount,
NodeIDs :=
"Productionline_Configuration".ReadLists."ReadListProduct".Nodes,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NamespaceIndexCount :=
"Productionline_Configuration".Namespaces.NamespaceCount,
NamespaceIndexes :=
"Productionline_Configuration".Namespaces.ServerNamespaceIndexes,
NodeStatusList :=
"Productionline_Data"."ReadListProduct".NodeStatusList,
NodeHdls :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeHdls,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);

Asynchronous execution

Manual, 11/2024 57
The instruction "OPC_UA_NodeGetHandleList" runs asynchronously to the user program and
requires multiple program cycles.
You can check the job status with the "Busy", "Done", "Error" and "Status" parameters.
Asynchronous program execution is described in the section "Difference between synchronous
and asynchronous instructions".

Explanation of the call of the instruction (initial call)


The program part in the figure above calls the "OPC_UA_NodeGetHandleList" instruction to
request handles for PLC tags.
If the instruction is not yet executed, #Busy is FALSE, so that the "#Req" tag is set to the value
TRUE. This starts the instruction. In the next cycle, #Req is FALSE.

Calling the instruction (troubleshooting)


The figure below shows evaluation of the "Done" and "Error" parameters.

SCL

IF #Done = TRUE THEN


IF "Productionline_Data"."ReadListProduct".NodeStatusList[0] = 0
AND "Productionline_Data"."ReadListProduct".NodeStatusList[1] = 0
THEN
#State := #State + 1;
ELSE
#State := 100;
#Mem_Status := #Status;
#Output_Error_Message := WString#'Error at
NodeGetHandleList';
END_IF;
END_IF;
IF #Error = TRUE THEN
#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconnect" to
FALSE
#Set_REQ_To_FALSE := TRUE;
#OPC_UA_NodeGetHandleList_Instance(REQ := FALSE,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeIDCount :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeCount,
NodeIDs :=
"Productionline_Configuration".ReadLists."ReadListProduct".Nodes,

58 Manual, 11/2024
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NamespaceIndexCount :=
"Productionline_Configuration".Namespaces.NamespaceCount,
NamespaceIndexes :=
"Productionline_Configuration".Namespaces.ServerNamespaceIndexes,
NodeStatusList :=
"Productionline_Data"."ReadListProduct".NodeStatusList,
NodeHdls :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeHdls);
END_IF;

Explanation of the call of the instruction (troubleshooting)


If an error occurs, the value of the "Error" output parameter is set to TRUE. This sets the value of
the "#State" tag to 100. This case is reserved for troubleshooting. The example program also
calls the instruction "OPC_UA_NodeGetHandleList" to set the REQ parameter to FALSE.
If the output parameter "Done" is TRUE, the instruction was executed successfully.
Note: It is possible that the instruction was successfully executed ("Error" parameter not set,
"Done" parameter set) but no handle could be returned for a specific PLC tag.
In the example program, therefore, there is a check to determine whether a handle is returned
for each PLC tag.

If a handle returns for the first tag, then the first element of the array to which the
"NodeStatusList" parameter is pointing contains the value 0.

If a handle returns for the second tag, then the second element of the array to which the
"NodeStatusList" parameter is pointing contains the value 0.

If both conditions are met, the output parameter "NodeHdls" points to a valid list with the
handles for the registered PLC tags.
The value of the "#State" tag is increased by one. This means the next program section - case 4 -
is executed in the next cycle.
Case 4 is described in OPC_UA_Readlist.

Note
If you register a large number of tags in your application with
OPC_UA_NodeGetHandleList, it can be useful always to increase #State by one
when #Done = TRUE. You should then check when using the requested values
whether the individual values are valid.

Tip: Programming general error handling


In order to keep the example program above (calling the instruction "error handling") clear and
easy to understand, only the handles for two PLC tags were queried and there was checked
whether a handle was returned for each tag. This type of query is quite inflexible.

Manual, 11/2024 59
If you scan the handles for more than two PLC tags in your program or if you want to write your
program independent of the number of PLC tags, you should use the following program code to
evaluate "NodeStatusList" in a loop:
IF #Done = TRUE THEN
FOR #i := 0 TO
UINT_TO_INT("Productionline_Configuration".ReadLists."ReadListProduct".NodeCoun
- 1 DO
IF NOT
("Productionline_Data"."ReadListProduct".NodeStatusList[#i] = 0) THEN
#Output_Error_Message := CONCAT_WSTRING(IN1 :=
WSTRING#'Error at NodeGetHandleList, Index: ',
IN2 := INT_TO_WSTRING(#i));
END_IF;
END_FOR;
#State := #State + 1;
END_IF;

What is the purpose of the parameter "NamespacesIndexes"?


The parameter "NamespaceIndexes" implements the indexes for the namespaces.
Implementation of indexes is necessary, for example, when you read the node identifiers in your
user program from an external list, for example, from an exported OPC UA XML file.
In this case you must enter the index that the OPC UA server is currently using for the
namespace for all identifiers in the list.
Besides, the indexes of the namespaces might change so that you have to adapt the list each
time.
Automatic change of the indexes
You can automatically implement the indexes of the namespaces: To do so, use the parameters
"NamespaceIndexes" and "NamespacesIndexCount" of the "OPC_UA_NodeGetHandleList"
instruction.
Follow these steps:

1. Check which namespace is assigned to the NodeIds that you read in from a list.

In the example, the NodeIds are assigned to namespace index 0.

In the example, the NodeIds are in the Siemens namespace


"http://www.siemens.com/simatic-s7-opcua".

2. Create an array of the type "WString".

In the example, the array is named "myNamespaces".

3. Enter the Siemens namespace "http://www.siemens.com/simatic-s7-opcua" under

"myNamespaces[0]" (also in array element 0).

4. Provide the "NamespaceUris" parameter with the new array "myNamespaces".

60 Manual, 11/2024
The instruction provides the result (the current index) at the parameter "NamespaceIndexes".

5. Create an array of the type "UInt" for the result.

In the example, the array is named "myNamespaceIndexes".

6. Provide the "NamespaceIndexes" parameter with the new array "myNamespaceIndexes".

7. Also assign this array "myNamespaceIndexes" to the "NamespacesIndexes" parameter of the

instruction "OPC_UA_NodeGetIndexList".

This instruction then reads the current index of the Siemens namespace from

"myNamespaceIndexes[0]" and uses it (instead of the original namespace index 0). This
implements the index.

8. Assign the value 1 to the "NamespacesIndexCount" parameter of the instruction


"OPC_UA_NodeGetIndexList" (we are using only one namespace in the example).

The following program code shows an implementation of the example:

SCL

#OPC_UA_NodeGetHandleList_Instance(REQ := #Req,
ConnectionHdl := #ConnectionHdl,
NodeIDCount := 2,
NodeIDs := #TargetNodeIds,
Timeout := T#6S,
NamespaceIndexCount := 1,
NamespaceIndexes := #myNamespaceIndexes,
NodeStatusList := #NodeStatusList,
NodeHdls := #NodeHdls,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);

The parameters "NamespaceIndexes" and "NamespaceIndexCount" are optional.


If index conversion is not required, the "NamespaceIndexes" and "NamespaceIndexCount"
parameters do not need to be supplied.
Index conversion is not required when the NodeIds are specified directly with the correct
namespace, e.g. when the NodeIds are determined using the "OPC_UA_TranslatePathList"
instruction.
See also
OPC_UA_TranslatePathList: Determine current NodeIds (S7-1500)
OPC UA instructions for client programs (S7-1500)

Manual, 11/2024 61
OPC_UA_ConnectionGetStatus: Read connection status (S7-1500)

1.1.1.3.5 OPC_UA_TranslatePathList: Determine current NodeIds (S7-1500)

Validity
The following description of the "OPC_UA_TranslatePathList" instruction applies to S7-1500 CPUs
with firmware version V2.6 and higher.

Description
You use the "OPC_UA_TranslatePathList" instruction to navigate (browse) in the address space of
an OPC UA server and determine the node ID (NodeId) of a node that the OPC UA server uses for
this node.
The instruction is used for use cases in which BrowseNames and the paths of the nodes are
defined, but the NodeIds are not known and can therefore differ from server to server.
In principle, the following applies: Start the navigation at a node whose NodeId is known. For
example, the nodes from the "http:\\opcfoundation.org/UA/" namespace of the OPC Foundation
are known.
Example of a start node: "Objects". Other possible start nodes are "DeviceSet" or an underlying
root node of the information model used in the address space of the server whose NodeId you
have determined.
The "Objekts" node is used in the example below. Starting from this start node, you use the
existing BrowseNames to navigate from node to node until you finally arrive at the destination
node. At the target node, you read out the sought after NodeId ("NodeID" attribute).
Example
An OPC UA server of a device publishes a server interface that meets the Companion
specification AutoID. The Companion specification defines the BrowseNames of OPC UA nodes.
This means that you know the BrowseNames of these nodes. However, you do not know which
NodeIds the OPC UA server that you are querying uses for these nodes. In this case, use the
"OPC_UA_TranslatePathList" instruction.
Alternative
STEP 7 (TIA Portal) offers you an alternative to the "OPC_UA_TranslatePathList" instruction. You
can create a client interface in STEP 7 under "Project tree", <CPU name>, "OPC UA
communication" and configure read, write or method lists. STEP 7 then automatically
determines the NodeIds of the node.
However, this alternative requires that you can reach the OPC UA server of this device online or
that you use the OPC UA XML file of the device.
Symbol of the instruction
The following figure shows the icon of the instruction in the editor (FBD).

62 Manual, 11/2024
In the figure above, the parameters of the instruction are not supplied yet.
OPC_UA_TranslatePathList is used to prepare the data exchange, see ① in the figure below.
To do this, provide the instruction with the browse paths; the instruction returns the NodeIds of
the nodes you are looking for.

① Instructions for preparation of read and write operations

② Read and write instructions

③ Instructions for releasing resources after completed read or write operations

Parameters for "OPC_UA_TranslatePathList"


The parameters of the instruction "OPC_UA_TranslatePathList"

Parameters Declaration Data Meaning


in area type

REQ Input BOOL A rising edge 0 → 1 at the parameter


triggers execution of the instruction.

Manual, 11/2024 63
ConnectionHdl Input DWORD Unique identifier for a connection
established.
You get the handle from the instruction
OPC_UA_Connect: Create connection.

BrowsePathsCount Input UINT Number of elements in BrowsePaths


(max. 10).

BrowsePaths InOut VARIANT Pointer to an array of the type


OPC_UA_BrowsePath.
The array contains the individual browse
paths you want to follow.

Timeout Input TIME Maximum time for execution of the


instruction in milliseconds.
See also the explanation for this
parameter in OPC_UA_Connect: Create
connection.

NamespaceIndexCount Input UINT Number of elements in


NamespaceIndexes.

NamespaceIndexes InOut VARIANT Pointer to an array of the type UINT.


This parameter is ignored if
NamespaceIndexCount is 0.
The array is used to convert the indexes
for the namespaces that are passed in the
BrowsePaths parameter.
Example:
If there is a value of 10 in
NamespaceIndexes[4], all NodeIds in the
"BrowsePaths" parameter that previously
had the namespace index 4 are assigned
the namespace index 10.

TargetNodeIDs InOut VARIANT Pointer to an array of the type


OPC_UA_NodeId.
The array contains the NodeIds found.

TargetStatusList InOut VARIANT Pointer to an array of the type DWORD.


The array contains the error numbers for
the individual browse paths.
The first element in the array refers to the
first element in the BrowsePaths
parameter, etc.; see "Error numbers for
TargetStatusList"

64 Manual, 11/2024
Done Output BOOL Status of execution:

0: Execution of the instruction aborted, not yet

complete or not yet started

1: Execution of instruction completed without errors

Busy Output BOOL Execution status parameter:

0: Instruction not being executed

1: Instruction currently being executed

Error Output BOOL Error display

0: No error

1: An error has occurred. See "Status" parameter.

Status Output DWORD Cause of the error, see "Error numbers for Status" below

"NamespacesIndexes" parameter
The "NamespaceIndexes" parameter for converting the namespace indexes is optional.

If you use this parameter ("NamespaceIndexCount" > 0), the namespace indexes of the

parameter "BrowsePaths" are converted (to references, BrowseNames and start nodes).

If you do not use this parameter as in the example below ("NamespaceIndexCount" = 0), the

namespace indexes in the "BrowsePaths" must be set correctly. This means the instruction

"OPC_UA_TranslatePathList" does not evaluate the "NamespaceIndexes"" parameter. If you


call the "OPC_UA_NodeGetHandleList" instruction in the next step, you also must not

convert the namespace indexes, since they are up to date. Therefore, set the

"NamespaceIndexCount" parameter of the instruction "OPC_UA_NodeGetHandleList" to 0.


Then you do not have to supply the "NamespaceIndexes" parameter.

Error numbers for Status


The "Status" parameter provides information about errors that occurred during execution of the
instruction.
The following table shows a summary of error codes for this instruction:

Error code Name of the error Explanation


(hexadecimal
values)

Manual, 11/2024 65
0000_0000 OpcUa_Good Instruction finished successfully.

0070_0000 - First call without rising edge at REQ,


which means job execution is not
started

0070_0100 - First call with start of job execution

0070_0200 - Subsequent call

8002_0000 OpcUa_BadInternalError An error occurred as a result of an


internal programming error in the
function block.
Contact Support.

8003_0000 OpcUa_BadOutOfMemory No memory available for the OPC UA


client.
As the OPC UA client and OPC UA server
share a memory area, you should
reduce the memory requirement of the
server.
You have the following options:

Release fewer PLC tags for OPC UA

Reduce the number of OPC UA

clients that are currently connected

to the server

Set up fewer subscriptions

8009_0000 OpcUa_BadUnknownResponse Server did not respond with the


expected number of results

800A_0000 OpcUa_BadTimeout A network timeout occurred.


Possible causes:

Connection to the OPC UA server is

too slow (insufficient capacity)

The network load is too high.

The OPC UA server is not available.

Possible remedy:

Check the URL of the OPC UA server

66 Manual, 11/2024
Increase the timeout setting
(higher value for the Timeout

parameter of the function block

OPC_UA_Connect).

800D_0000 OpcUa_BadServerNotConnected The server is not connected or the


connection handle is incorrect or
invalid.

800F_0000 OpcUa_BadNothingToDo Nothing to do: The OPC UA server


received an empty list with no
instructions from the OPC UA client.

8010_0000 OpcUa_BadTooManyOperations Number of


"OPC_UA_TranslatePathList"
instructions that can be called at the
same time per connection has been
exceeded
(> 1), see: Number of client
instructions that can be used
simultaneously

80AE_0000 BadConnectionClosed The connection with the


corresponding ConnectionHdl is in
"ShutDown" status (connection
terminated). The connection/session
could not be "reactivated"
automatically. Possible cause: Session
deleted on the server, e.g. due to
restart or timeout).
In this case, you must explicitly close
the connection with the instruction
"OPC_UA_Disconnect" and release the
connection resources again. In your
user program, you must reset the
ConnectionHdl that has become
invalid for this connection.
Then you have to establish a new
connection to the server (see
instruction "OPC_UA_Connect").

80AF_0000 BadInvalidState The connection with the


corresponding ConnectionHdl is has
the "ConnectinError" status
(temporary connection error,
connection interrupted). The CPU tries
to "reactivate" the connection. If this
does not succeed in the set timeout
interval (OPC UA Session Timeout),
the connection goes into the

Manual, 11/2024 67
"Shutdown" state. Requirements for
the state transition: The CPU could
reach the OPC UA server to check
whether or not the session is still
active.

B080_0100 Simatic_BadType_VariantInput1 Incorrect data type for parameter


"BrowsePaths".

B080_0200 Simatic_BadType_VariantInput2 Incorrect data type for parameter


"NamespaceIndexes".

B080_0300 Simatic_BadType_VariantInput3 Incorrect data type for parameter


"TargetNodeIDs".

B080_0400 Simatic_BadType_VariantInput4 Incorrect data type for parameter


"TargetStatusList".

B080_1100 Simatic_ArrayElements_TooMany BrowsePathscount >


MAX_ELEMENTS_RELATIVEPATH

B080_3100 BadNumElements_VariantInput1 BrowsePathsCount > Number of array


elements of the "BrowsePaths"
parameter.

B080_3200 BadNumElements_VariantInput2 NamespaceIndexCount > Number of


array elements of the
"NamspaceIndexes" parameter.

B080_3300 BadNumElements_VariantInput3 BrowsePathsCount > Number of array


elements of the "TargetNodeIDs"
parameter.

B080_3400 BadNumElements_VariantInput4 BrowsePathsCount > Number of array


elements of the "TargetStatusList"
parameter.

B080_C400 Simatic_ClientNotEnabled The OPC UA client is disabled.

B080_C500 Simatic_NothingToDo Nothing to do: Parameter


"BrowsePathsCount" is not supplied
or "BrowsePathsCount" = 0.

B080_C600 Simatic_ClientNotAvailable Error during initialization of the client

C080_C300 Simatic_OutOfResources The maximum number of client


instructions that can be used at the
same time has been exceeded.
Possible remedy:

68 Manual, 11/2024
Reduce the number of client instructions of this type running in parallel,
see:Number of client instructions that can be used simultaneously

For more error codes, see Error codes.

Error numbers for "TargetStatusList"


The "TargetStatusList" parameter contains an error code for each individual NodeId (tag).
The following table explains the error codes:

Error code Name of the error Explanation


(hexadecimal
values)

0000_0000 OpcUa_Good Value successfully read.

8033_0000 OpcUa_BadNodeIdInvalid The syntax of the NodeId is


incorrect.

8034_0000 OpcUa_BadNodeUnknown The node handle transferred is


not known.

8035_0000 OpcUa_BadAttributeInvalid The attribute required is not


supported for the specified
node.

8037_0000 OpcUa_BadIndexRangeNoD There is no data in the index


range.

8039_0000 OpcUa_BadDataEncodingUnsupported The OPC UA server does not


support the required data
decoding for this node.

803A_0000 OpcUa_BadNotReadable No rights for reading or


subscribing (Subscribing) this
node.

803C_0000 OpcUa_BadOutOfRange The index value specified in


the NodeAddInfos parameter
is outside the permitted
range.

803D_0000 OpcUa_BadNotSupported The OPC UA server does not


support one of the requested
functions. Some OPC UA
servers do not allow access to
the index ranges of an array.

Manual, 11/2024 69
8060_0000 OpcUa_BadBrowseNameInvalid The NamespaceIndex of the
QualifiedName does not exist.

806F_0000 OpcUa_BadNoMatch The specified path does not lead to a


node.

For more error codes, see Error codes.

This is how you use this instruction


Based on an example, this section shows you how to use the instruction
"OPC_UA_TranslatePathList" in a program.
Example
Let us assume that RFID readers scan the outgoing goods at the gates of a plant.
In the example, the first reader is called "RfidReader_Door_1".
The RFID readers are OPC UA servers that make their data and methods available to OPC UA
clients.
Specification AutoID
The RFID readers come with a standardized interface according to the Companion Specification
"AutoID".
The names of the properties and methods of the RFID readers are specified by the
standardization.
The figure below shows a section of the address space of the reader "FfidReaderDoor_1" in
UAExpert, a tool from Unified Automation.
The node "RfidReader_Door_1" is located under "DeviceSet".
Below it, you can see the released properties and methods of the reader according to the
AutoId:

70 Manual, 11/2024
The properties and methods of the reader are known because the reader adhere to the AutoID
specification.
Not known are the following elements:

The name "RfidReader_Door_1". The name can be freely selected or is specified in the

respective plant.

The NodeId of the "RfidReader_Door_1" node in the address space of the reader

The NodeIds of the properties and methods of the reader, which means all nodes below
"RfidReader_Door_1", see figure above.

Procedure for determining NodeIds

You work with a client interface and configure a read, write or method list via drag-and-drop.

To do this access the OPC UA server online or use the OPC UA XML file of the server that

contains the NodeIds of the tags you are looking for. STEP 7 (TIA Portal) then automatically

determines the NodeIDs of the tag.

It is not necessary to call the "OPC_UA_TranslatePathList" instruction here.

You are using a tool such as UAExpert:

Manual, 11/2024 71
- Read the NodeId from "RfidReader_Door_1".

- Read the NodeIds of all lower-level properties and methods of this reader that you want

to use in your user program.

The next step in your program is the call of "OPC_UA_NodeGetHandleList".

You are working with the instruction "OPC_UA_TranslatePathList".

You first define the browse path (BrowsePath) for this instruction. This path can start at the
"Objects" node but also any other node whose NodeId you are familiar with.

The NodeId "i=85" is always assigned to the "Objects" node (according to the OPC UA
specification). The following example uses a BrowsePath that originates from the "Objects"

node. After you have determined the NodeIds of the tags you are looking for with

"OPC_UA_TranslatePathList", use these NodeIDs in the next step when calling the
"OPC_UA_NodeGetHandleList" instruction.

Introduction to the program example


The following program example shows you how to use the "OPC_UA_TranslatePathList"
instruction to determine the NodeIds for two tags.
The tags sought after in the example are "DeviceInfo" and "DeviceStatus", the path used
(BrowsePath) starts at the "Objects" node (NodeId: i=85) and leads to the tags searched for via
"productionline", "DataBlocksGlobal" and "RfidReader_Door_1", see figure below.

Requirement
The following requirement must be fulfilled for the "OPC_UA_TranslatePathList" instruction:

A handle for connection to an OPC UA server is available.

You get the connection handle from the instruction OPC_UA_Connect: Create connection.

72 Manual, 11/2024
You can use the connection configuration for OPC UA in TIA Portal to configure a connection
to an OPC UA server.

If you do not use this connection configuration, you have to set the connection parameters
in your user program. How to proceed is shown in the section "Establishing a connection to

an OPC UA server" in the further course of this description.

Calling the instruction (initial call)


This section describes the function block "Read_from_RfidReader_Door_1". The function block
shows you how to use the instruction "OPC_UA_TranslatePathList".
You can find the complete example in the section "Example program for
OPC_UA_TranslatePathList".
Declaration of tags
Declare an instance of the instruction "OPC_UA_TranslatePathList" and the tags with which you
are supplying the instruction parameters.
The program example uses the following declaration:

User program
The following excerpt from the user program defines the browse path for the PLC tag
"DeviceInfo". The definition for "DeviceStatus" is not shown.
First, the start node (StartingNode) is defined. This leads to the browse path of the node you are
looking for. The path to the node (RelativePath) you are looking for is defined below.
The first browse path (BrowsePaths[0]) starts at the "Objects" node (NodeId i=85) and leads to
the searched "DeviceInfo" tag via "productionline", "DataBlocksGlobal" and "RfidReader_Door_1".
Define start nodes
The following user program first sets the start node to "Objects".
The "Objects" node was defined by the OPC Foundation in the namespace
"http://opcfoundation.org/UA/". The index 0 in the namespace array of an OPC UA server is
always assigned to this namespace.
OPC UA servers publish this namespace array in their address space so that OPC UA clients can
use the index instead of the namespace to address a node.
The "Objects" node has the NodeId "i=85", with the namespace index 0 (namespace index 0 is
not specified to simplify the NodeId).
The NodeId "i=85" also indicates the type of identifier: This NodeId is a numeric identifier (an
integer).
The following program lines pass the identifier "85", determine the type of the identifier and set
the namespace index:
#BrowsePaths[0].StartingNode.Identifier := WString#'85';
#BrowsePaths[0].StartingNode.IdentifierType := 0;
#BrowsePaths[0].StartingNode.NamespaceIndex := 0;

Manual, 11/2024 73
Define RelativePath
The first stage of the navigation in the following program example leads to the node with the
BrowseName "productionline".
Then the navigation continues to the nodes with the BrowseNames "DataBlocksGlobal",
"RfidReader_Door_1" and finally "DeviceInfo".
In the program example, these nodes are all in the namespace
"http://www.siemens.com/simatic-s7-opcua". The index of this namespace is stored in the local
tag "#NamespaceIndexes[0]" and is set directly in the program code.
References for OPC UA
The address space of an OPC UA server consists of OPC UA nodes that refer to each other. These
pointers from one node to another are called references. OPC UA defines several types of
references.
The following program example uses the hierarchical reference to determine the NodeIds of OPC
UA nodes located below another OPC UA node.
Reference used in the example: The node with the BrowseName "DeviceInfo" is arranged below
"RfidReader_Door_1". This means that the two nodes have a hierarchical relationship to each
other.

SCL

//Sets the first BrowsePath, BrowsePath[0]


//This BrowsePath starts at node "Objects" and leads to node
"DeviceInfo"
//First, we assign "Objects" to "StartingNode".
//"Objects" has always NodeId i=85. It is a numerical NodeId
with namespaceindex 0.
#BrowsePaths[0].StartingNode.Identifier := WString#'85';
#BrowsePaths[0].StartingNode.IdentifierType := 0;
#BrowsePaths[0].StartingNode.NamespaceIndex := 0;

//Second, we set "RelativePath".


//Our BrowsePath goes to "productionline",
"DataBlocksGlobal", "RfidReader_Door_1",
//and finally to "DeviceInfo".
//Therefore, we set "NoOfElements" to four elements.
#BrowsePaths[0].RelativePath.NoOfElements := 4;

//The first element of our RelativePath is "productionline'.


//Therefore, we set "TargetName.Name" to "productionline'
//In our example code, the namespaceindex of "productionline'
is stored
//in our local variable "#NamespaceIndexes[0]";

74 Manual, 11/2024
//"Objects" via a HierarchicalReference.
//This reference always has the numerical NodeId i=33 assigned to it,
with namespaceindex 0.
//This reference is set by default.
//Therefore, you can skip the following three lines of code.
#BrowsePaths[0].RelativePath.Elements[1].ReferenceTypeId.Identifier :=
WString#'33';
#BrowsePaths[0].RelativePath.Elements[1].ReferenceTypeId.IdentifierType
:= 0;
#BrowsePaths[0].RelativePath.Elements[1].ReferenceTypeId.NamespaceIndex
:= 0;
#BrowsePaths[0].RelativePath.Elements[1].TargetName.Name :=
WString#'productionline';
#BrowsePaths[0].RelativePath.Elements[1].TargetName.NamespaceIndex :=
#NamespaceIndexes[0];

//The second element of our RelativePath is "DataBlocksGlobal'.


#BrowsePaths[0].RelativePath.Elements[2].TargetName.Name :=
WString#'DataBlocksGlobal';
#BrowsePaths[0].RelativePath.Elements[2].TargetName.NamespaceIndex :=
#NamespaceIndexes[0];

//The third element of our RelativePath is "RfidReader_Door_1'.


#BrowsePaths[0].RelativePath.Elements[3].TargetName.Name :=
WString#'RfidReader_Door_1';
#BrowsePaths[0].RelativePath.Elements[3].TargetName.NamespaceIndex :=
#NamespaceIndexes[0];

//The fourth element of our RelativePath is "DeviceInfo'.


#BrowsePaths[0].RelativePath.Elements[4].TargetName.Name :=
WString#'DeviceInfo';
#BrowsePaths[0].RelativePath.Elements[4].TargetName.NamespaceIndex :=
#NamespaceIndexes[0];

Establishing a connection to an OPC UA server


The following section of the example program shows you how to manually (with a program)
configure a connection to an OPC UA server in your user program without using the connection
configuration provided by STEP 7 (TIA Portal).
The SCL program assigns corresponding values to the parameters for this purpose.
The program example first defines the server endpoint "opc.tcp://192.168.1.1:4840", because
the "opc.tcp" protocol is used for OPC UA and the server has the IP address "192.168.1.1".

Manual, 11/2024 75
Security mode "2" (SecurityMsgMode) is set so that messages are transmitted signed. The value
"Basic128Rsa15" is set as the procedure for signing (SecurityPolicy). The number of the client
certificate (CerificateID) is also specified. The number 6 is used in the example.

SCL

76 Manual, 11/2024
CASE #State OF
1: // case 1, connect to server
IF #FirstCall = TRUE THEN
#FirstCall := FALSE;
//set ServerEndPointUrl of the server we want to connect
to
#SeverEndpointUrl :=
WString#'opc.tcp://192.168.1.1:4840';
//set Securtiy Message Mode
// 1 = None, 2 = Sign, 3 = Sign & Encrypt
#SessionConnectInfo.SecurityMsgMode := 1;
//set Security Policy
// 1 = None, 2 = Basic128Rsa15,, 3 = Basic256, 4 =
Basic256Sha256
#SessionConnectInfo.SecurityPolicy := 2;
//set the number of the client certificate you are using
//in our case, this is 6
//#SessionConnectInfo.CertificateID := 6;
END_IF;
IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_Connect_Instance(REQ:=#Req,
ConnectionHdl=>#ConnectionHdl,
ServerEndpointUrl:=#SeverEndpointUrl,
SessionConnectInfo:=#SessionConnectInfo,
Timeout:=T#8S,
Done=>#Done,
Busy=>#Busy,
Error=>#Error,
Status=>#Status);

Determining the NodeIds of the DeviceInfo and DeviceStatus nodes


The following excerpt from the example program "Read_From_RfidReader_Door_1" queries the
OPC UA server for NodeIds of nodes with the BrowseName "DeviceInfo" and "DeviceStatus".

Manual, 11/2024 77
You can find the complete example in the section "Example program for
OPC_UA_TranslatePathList".

SCL

IF #Busy = FALSE THEN


#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_TranslatePathList_Instance(REQ := #Req,
ConnectionHdl := #ConnectionHdl),
BrowsePathsCount := 2,
BrowsePaths := #BrowsePaths,
Timeout := T#6S,
NamespaceIndexCount := 0,
TargetNodeIDs := #TagetNodeIds,
TargetStatusList := #TargetStatusList,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
IF #TargetStatusList[0] = 0 AND #TargetStatusList[1] = 0
THEN
#State := #State + 1;
ELSE
#State := 100;
#Mem_Status := #Status;
#Output_Error_Message := WString#'Error at
TranslatePathList';
END_IF;
#FirstCall := TRUE;
END_IF;
IF #Error = TRUE THEN
//In case 100, to set REQ of instruction
"OPC_UA_TranslatePathList" to FALSE
#Set_REQ_To_FALSE := TRUE;

78 Manual, 11/2024
#State := 100;
#Mem_Status := #Status;
#OPC_UA_TranslatePathList_Instance(REQ := FALSE,
ConnectionHdl := #ConnectionHdl,
BrowsePathsCount := 2,
BrowsePaths := #BrowsePaths,
TargetNodeIDs := #TagetNodeIds,
TargetStatusList := #TargetStatusList);
#FirstCall := TRUE;
END_IF;

The example program calls the "OPC_UA_TranslatePathList" instruction for the following reasons:

To request the NodeId for the nodes with BrowseName "DeviceInfo" and "DeviceStatus".

To set the REQ parameter to FALSE, if an error has occurred.

Asynchronous execution
The instruction "OPC_UA_TranslatePathList" runs asynchronously to the user program and
requires multiple program cycles.
You can check the job status with the "Busy", "Done", "Error" and "Status" parameters.
Asynchronous program execution is described in the section "Difference between synchronous
and asynchronous instructions".

Explanation of how to determine the NodeIds


If the "OPC_UA_TranslatePathList" instruction is not yet executed, #Busy is FALSE so that the
"#Req" tag is set to TRUE. This starts the instruction.
In the next cycle, #Req is FALSE.
If the output parameter "Error" is TRUE, an error occurred during execution of the instruction.
This sets the "#State" tag to the value 100. This case is reserved for troubleshooting.
If the output parameter "Done" is TRUE, the instruction was executed successfully.
Note: It is possible that the instruction was successfully executed ("Error" parameter not set,
"Done" parameter set) but no NodeId could be returned for a PLC tag.
Therefore, there is a check in the example to determine whether the program has obtained a
NodeId for each PLC tag:

If a NodeId is returned for the first tag, the first element of the array to which the

"TargetStatusList" parameter is pointing contains the value 0.

If a NodeId is returned for the second tag, the first element of the array to which the

"TargetStatusList" parameter is pointing contains the value 0.

If both conditions are met, the output parameter "TargetNodeHdls" points to a valid list with the
NodeIds. This increases the value of the "#State" tag by one. The next program section - Case 4 -
is then executed in the next cycle.
Case 4 is described in OPC_UA_NodeGetHandleList: Get handles for read and write access.

Manual, 11/2024 79
See also
OPC_UA_NamespaceGetIndexList: Read namespace indexes (S7-1500)
OPC_UA_NodeAdditionalInfo (S7-1500)
OPC_UA_NodeAdditionalInfoExt (S7-1500)
OPC_UA_ConnectionGetStatus: Read connection status (S7-1500)

1.1.1.4 Data exchange (S7-1500)

1.1.1.4.1 OPC_UA_ReadList: Reading tags (S7-1500)

Validity
The following description of the "OPC_UA_ReadList" instruction applies to S7-1500 CPUs with
firmware version V2.6 and higher.

Description
You use the instruction "OPC_UA_ReadList" to read the values of PLC tags.
The following figure shows the icon of the instruction in the editor (FBD).

In the figure above, the parameters of the instruction are not supplied yet.
The instruction "OPC_UA_ReadList" is used to read tags from a OPC UA server, see ② in the
figure below.
The instruction returns a list with values of tags.
In addition to the tag values, you can also read other tag attributes. This is specified by the
AttributeID, see OPC_UA_NodeAdditionalInfo.

80 Manual, 11/2024
① Instructions for preparation of read and write operations

② Read and write instructions

③ Instructions for releasing resources after completed read or write operations

Note
Firmware dependency when reading OPC UA arrays
Up to and including firmware version V2.9, the size of an array that is part of a
structure in your program must exactly match the size of the OPC UA array that is
read. As of firmware version V3.0, the array size in the PLC program may be larger
than the size of the read OPC UA array. It is recommended that you completely
reset the values in your program before the read operation, because the firmware
of the PLC does not do this. If the currently read array is smaller than the previously
read one, there is a risk that you are accessing old or invalid values in your
program.
The following applies in regard to compatibility: Accesses that have worked so far
will continue to work. Accesses that were previously incorrect may now return
values.

Parameters for "OPC_UA_ReadList"


The parameters of the instruction "OPC_UA_ReadList"

Parameters Declaration Data type Meaning

REQ Input BOOL A rising edge 0 → 1 at the


parameter triggers execution of the
instruction.

ConnectionHdl Input DWORD Unique identifier for a connection


established.
You get the handle from the
instruction OPC_UA_Connect:
Create connection.

NodeHdlCount Input UINT Number of elements in the array


that points to the NodeHdls
parameter.

Manual, 11/2024 81
NodeHdls InOut VARIANT Pointer to an array of the type DWORD.
The array contains the node handles of the tags
whose values are to be read.

NodeAddInfos InOut VARIANT Pointer to an array of the type


OPC_UA_NodeAdditionalInfo or
OPC_UA_NodeAdditionalInfoExt.
The array defines which attribute is to be read in
the node (in a tag).
The first element in this array refers to the first
element in the array to which the "NodeHdls"
parameter points.
The parameter is optional. If it is not set, the
values of all nodes (tags) are read.
When reading arrays, you can limit which
elements of the array are to be read, see
Reading array range information with
OPC_UA_ReadList.

Timeout Input TIME Maximum time for execution of the instruction


in milliseconds.
See also the explanation for this parameter
inOPC_UA_Connect: Create connection.

NodeStatusList InOut VARIANT Pointer to an array of the type DWORD.


The array contains the error codes for the
individual tags (see "Error numbers for
NodeStatusList" below).
For each tag, it is specified whether its value
could be read.
It is possible that the instruction was
successfully executed (Error parameter not set)
but no value could be read for a specific NodeId
(tag).

TimeStamps InOut VARIANT Pointer to an array of the type LDT.


The first element in this array refers to the first
element in the array to which the NodeHdls
parameter points.
The parameter is optional. If it is not set, the
OPC UA server does not return a time stamp.

Variable InOut VARIANT Pointer to a tag that saves the values to be read.
You must create a PLC data type (UDT) or a
structure (STRUCT) for this tag.

Done Output BOOL Status of execution:

82 Manual, 11/2024
0: Execution of the instruction aborted, not yet
complete or not yet started

1: Execution of instruction completed without errors

Busy Output BOOL Execution status parameter:

0: Instruction not being executed

1: Instruction currently being executed

Error Output BOOL Error display

0: No error

1: An error has occurred. See "Status" parameter

Status Output DWORD Cause of the error, see "Error numbers for Status" below

Error numbers for Status


The "Status" parameter provides information about errors that occurred during execution of the
instruction.
The following table shows a summary of error codes for this instruction:

Error code Name of the error Explanation


(hexadecimal
values)

0000_0000 OpcUa_Good Function block executed


successfully.

0070_0000 - First call without rising edge at


REQ, which means job execution
is not started

0070_0100 - First call with start of job


execution

0070_0200 - Subsequent call

Manual, 11/2024 83
Release fewer PLC tags for OPC
UA.

Reduce the number of OPC UA


clients that are currently connected

to the server.

Set up fewer subscriptions.

8009_0000 OpcUa_BadUnknownResponse Server did not respond with the


expected number of results

800A_0000 OpcUa_BadTimeout A network timeout occurred.


Possible causes:

Connection to the OPC UA server


is too slow (insufficient capacity)

The network load is too high.

The OPC UA server is not available.

Possible remedy:

Check the URL of the OPC UA


server

Increase the timeout setting


(higher value for the Timeout

parameter of the function block

OPC_UA_Connect).

800D_0000 OpcUa_BadServerNotConnected The server is not connected or the


connection handle is incorrect or
invalid.

800F_0000 OpcUa_BadNothingToDo Nothing to do: The OPC UA server


received an empty list with no
instructions from the OPC UA client.

8010_0000 OpcUa_BadTooManyOperations Number of "OPC_UA_ReadList"


instructions that can be called at the
same time per connection has been
exceeded (> 5), see: Number of client
instructions that can be used
simultaneously

84 Manual, 11/2024
server.

80AE_0000 BadConnectionClosed The connection with the


corresponding ConnectionHdl is in
"ShutDown" status (connection
terminated). The connection/session
could not be "reactivated"
automatically. Possible cause: Session
deleted on the server, e.g. due to
restart or timeout).
In this case, you must explicitly close
the connection with the instruction
"OPC_UA_Disconnect" and release the
connection resources again. In your
user program, you must reset the
ConnectionHdl that has become invalid
for this connection.
Then you have to establish a new
connection to the server (see
instruction "OPC_UA_Connect").

80AF_0000 BadInvalidState The connection with the


corresponding ConnectionHdl is has
the "ConnectinError" status (temporary
connection error, connection
interrupted). The CPU tries to
"reactivate" the connection. If this does
not succeed in the set timeout interval
(OPC UA Session Timeout), the
connection goes into the "Shutdown"
state. Requirements for the state
transition: The CPU could reach the
OPC UA server to check whether or not
the session is still active.

B080_0100 Simatic_BadType_VariantInput1 Incorrect data type for parameter


"NodeHdls".

B080_0200 Simatic_BadType_VariantInput2 Incorrect data type for parameter


"NodeAddInfos".

B080_0300 Simatic_BadType_VariantInput3 Incorrect data type for parameter


"NodeStatusList".

B080_0400 Simatic_BadType_VariantInput4 Incorrect data type for parameter


"TimeStamps".

B080_0500 Simatic_BadType_VariantInput5 Incorrect data type for parameter


"Variable" (not UDT).

Manual, 11/2024 85
B080_1100 Simatic_ArrayElements_TooMany NodeHdlCount >
MAX_ELEMENTS_NODELIST
NamespaceIndexCount >
MAX_ELEMENTS_NAMESPACES

B080_3100 BadNumElements_VariantInput1 The "NodeHdlCount" parameter is


greater than the number of ARRAY
elements in the "NodeHdls"
parameter.

B080_3200 BadNumElements_VariantInput2 The "NodeHdlCount" parameter is


greater than the number of ARRAY
elements in the "NodeAddInfos"
parameter.

B080_3300 BadNumElements_VariantInput3 The "NodeHdlCount" parameter is


greater than the number of ARRAY
elements in the "NodeStatusList"
parameter.

B080_3400 BadNumElements_VariantInput4 The "NodeHdlCount" parameter is


greater than the number of ARRAY
elements in the "TimeStamps"
parameter.

B080_3500 BadNumElements_VariantInput5 The PLC data type/structure for the


parameter "Variable" has too few or
too many elements as specified by
the value for the parameter
"NodeHdlCount".
Example: If "NodeHdlCount" has the
value 5, then the array "NodeHdls"
must also contain 5 elements. The
structure for the parameter
"Variable" must also consist of 5
elements.

B080_C400 Simatic_ClientNotEnabled The OPC UA client is disabled.

B080_C500 Simatic_NothingToDo Nothing to do: The instruction is


using a list that contains no
elements.

C080_C300 Simatic_OutOfResources The maximum number of client


instructions that can be used at the
same time has been exceeded.
Possible remedy:

Reduce the number of client

instructions of the type running

86 Manual, 11/2024
parallel, see:

Number of client instructions that can be used simultaneously

For more error codes, see Error codes.

Error numbers for "NodeStatusList"


The "NodeStatusList" parameter contains an error code for each individual node handle (tag).
The following table explains the error codes:

Error code Name of the error Explanation


(hexadecimal
values)

0000_0000 OpcUa_Good Value successfully read.

8034_0000 OpcUa_BadNodeIdUnknown The node handle


transferred is not known.

8035_0000 OpcUa_BadAttributeInvalid The attribute required is


not supported for the
specified node.

8037_0000 OpcUa_BadIndexRangeNoD There is no data in the


index range.

8039_0000 OpcUa_BadDataEncodingUnsupported The OPC UA server does


not support the required
data decoding for this
node.

8074_0000 OpcUa_BadTypeMismatch Double / Float value in


ReadResponse is NaN
UDT Member tag has
incorrect type

803A_0000 OpcUa_BadNotReadable No rights for reading or


subscribing (Subscribing)
this node.

803C_0000 OpcUa_BadOutOfRange The index value specified


in the NodeAddInfos
parameter is outside the
permitted range.

Manual, 11/2024 87
Some OPC UA servers do not allow access
to the index ranges of an array.

80AB_0000 OpcUa_BadInvalidArgument StartIndex > EndIndex

For more error codes, see Error codes.

This is how you use this instruction


Based on a program example, this section shows you how to use the instruction
"OPC_UA_ReadList" in a user program that reads the values of PLC tags.

Requirements
The following description assumes that:

You have created a client interface, see "Creating client interfaces".

You have created and configured a connection to an OPC UA server, see "Creating and

configuring connections".

If the CPU is to read and write structures in the OPC UA server as an OPC UA client: The

OPC UA server supports version V1.04 of the OPC UA specification.

The following requirements must also be met for the "OPC_UA_ReadList" instruction:

A handle for connection to an OPC UA server is available.

You get the connection handle from the following instruction: OPC_UA_Connect: Create
connection.

A list of the handles for the individual tags whose values you want to read from the OPC UA
server.

You get the handle list from the following instruction: OPC_UA_NodeGetHandleList: Get
handles for read and write access

Function of the instruction


You use the instruction "OPC_UA_ReadList", for example, to read the values of tags from an OPC
UA server (see above).
What information is required?
The instruction requires the following information:

The handles for the tags whose values you want to read ("NodeHdls" parameter).

What information does the instruction return?


The instruction returns the following information:

The current values of the tags the ("Variable" parameter).

88 Manual, 11/2024
The order of the values corresponds to the order of the handles in the "NodeHdls"
parameter.

Refer to the following cases for this purpose:

- When you use a client interface with a read list, STEP 7 automatically creates a system

data type with the tags that need to be read.

- If you are not using a client interface, you must create a PLC data type (UDT) or a

structure (STRUCT) for the "Variable" parameter.

You define the components of this UDT according to the tags that have to be read.

Use the SIMATIC data type compatible with the respective OPC UA data type, see

Mapping SIMATIC data types to OPC UA data types.

A list of error messages ("NodeStatusList" parameter).

Each error message in this list relates to the corresponding handle in the "NodeHdls"
parameter, NodeStatusList[0] refers to NodeHdls[0].

For each individual tag (each individual "NodeHdl"), you need to check whether the OPC UA
server was able to return a valid value.

How to use a configured connection


1. In the "Project tree" area, select the CPU that acts as the client.

2. Select the function block that is to contain the client instruction in the "Program blocks"
folder.

In the example, the function block is called "ReadFromProductionline".

Selected language: SCL.

3. Use drag-and-drop to move the instruction "OPC_UA_ReadList" from the folder "Instructions

> Communication > OPC UA > OPC UA Client" to the editor.

4. Select the call as multi-instance.

STEP 7 creates an instance of this instruction: "OPC_UA_ReadList_Instance".

5. Click on the icon for "Start configuration" at the "OPC_UA_ReadList_Instance" instruction.

STEP 7 opens the "Configuration" tab in the Inspector window.

6. Under "Select client interface for OPC UA interface" you select the client interface that you
want to use for the instruction.

Manual, 11/2024 89
In the example, the client interface is named "Productionline".

7. Click "Data access" and select a read list.

In the example, the read list is named "ReadListProduct".

STEP 7 now automatically supplies the parameters of the instruction with the values you
have configured for the client interface.

8. Click on "Block parameters" and assign tags manually to the remaining parameters REQ,
Busy, Done, Error, Status.

STEP 7 adds the selected tag to the function call.

Calling the instruction (initial call)


You can find the complete program in the section "Program example for reading PLC tags".
The program example uses the read list "ReadListProduct", which contains the following PLC
tags:

NewProduct

ProductNumber

The program reads the values of these tags from the server.
The section Creating client interfaces shows you how to create a client interface and how to add
a read list with PLC tags to it.
The example program is divided into multiple sections (cases) by a CASE instruction.
In the fourth program section, the tag values are read:

SCL

4: // case 4, read from nodes


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
OPC_UA_ReadList_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeHdlCount :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeCount,
NodeHdls :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeHdls,

90 Manual, 11/2024
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NodeStatusList :=
"Productionline_Data"."ReadListProduct".NodeStatusList,
TimeStamps :=
"Productionline_Data"."ReadListProduct".TimeStamps,
Variable :=
"Productionline_Data"."ReadListProduct".Variable,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);

Asynchronous execution
The instruction "OPC_UA_ReadList" runs asynchronously to the user program and requires
multiple program cycles.
You can check the job status with the "Busy", "Done", "Error" and "Status" parameters.
Asynchronous program execution is described in the section "Difference between synchronous
and asynchronous instructions".

Explanation of the call of the instruction (initial call)


The figure above shows case 4.
This part of the program calls the "OPC_UA_ReadList" instruction to read the values of PLC tags.
If the instruction is not yet executed, #Busy is FALSE, so that the "#Req" tag is set to the value
TRUE. This starts the instruction. In the next cycle, #Req is FALSE.

Calling the instruction (troubleshooting)


The figure below shows evaluation of the "Done" and "Error" parameters.

SCL

IF #Done = TRUE THEN


FOR #i := 0 TO
UINT_TO_INT("Productionline_Configuration".ReadLists."ReadListProduct".N
- 1 DO
IF NOT ("Productionline_Data"."ReadListProduct".NodeStatusList[#
THEN
#Output_Error_Message := CONCAT_WSTRING(IN1 := WSTRING#'Er
Readlist "ReadListProduct", Index: ',
IN2 := INT_TO_WSTRING(#i));
END_IF;
END_FOR;
#State := #State + 1;

Manual, 11/2024 91
END_IF;
IF #Error = TRUE THEN
#State := 100;
//In case 100, to set REG of instruction "OPC_UA_Disconnect" to
FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#OPC_UA_ReadList_Instance(REQ := FALSE,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeHdlCount :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeCount,
NodeHdls :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeHdls,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NodeStatusList :=
"Productionline_Data"."ReadListProduct".NodeStatusList,
TimeStamps :=
"Productionline_Data"."ReadListProduct".TimeStamps,
Variable :=
"Productionline_Data"."ReadListProduct".Variable);
END_IF;

Explanation of the call of the instruction (troubleshooting)


If an error occurs, the "Error" output parameter is set to the value TRUE. This sets the value of the
"#State" tag to 100. This case is reserved for troubleshooting. The example program also calls
the "OPC_UA_ReadList" instruction to set the REQ parameter to FALSE.
If the TRUE value is in the "Done" output parameter, the instruction is successfully executed.
Note: It is possible that the instruction was successfully executed ("Error" parameter not set,
"Done" parameter set) but no PLC tag could be read.
Therefore, there is a check in the example for each PLC tag to determine whether the program
has obtained a valid value:

If the server is sending a valid value for the first PLC tag, the first element of the array to
which the "NodeStatusList" parameter is pointing contains the value 0.

In the example, the status code is listed in


"Productionline_Data"."ReadListProduct".NodeStatusList[0].

If the server is sending a valid value for the second PLC tag, the second element of the array
to which the "NodeStatusList" parameter is pointing contains the value 0.

92 Manual, 11/2024
In the example, the status code is listed in
"Productionline_Data"."ReadListProduct".NodeStatusList[1].

The program outputs an error message when it recognizes an invalid value.


Even if one or two invalid values are detected, the value of the "#State" tag is increased by one.
This means the next program section - case 5 - is executed in the next cycle.
Case 5 is described in OPC_UA_NodeReleaseHandleList: Release handles for read and write
access.
See also
OPC_UA_NamespaceGetIndexList: Read namespace indexes (S7-1500)
OPC_UA_NodeId (S7-1500)
OPC_UA_TranslatePathList: Determine current NodeIds (S7-1500)
OPC UA instructions for client programs (S7-1500)

1.1.1.4.2 Reading array range information with OPC_UA_ReadList (S7-1500)

Introduction
This section is based on "OPC_UA_ReadList"; see OPC_UA_ReadList: Reading tags.
The section describes how to read parts of an array with the "OPC_UA_ReadList" instruction.
Reading parts of an array from an OPC UA server basically works as follows:

① Reading parts of an array from an OPC UA server

Requirements
The following description assumes that:

You have configured a CPU as OPC UA server.

The server provides an array that can be read by OPC UA clients.

In the example, the CPU is called "Productionline", which provides the data block
"Data_for_OPC_UA_Clients" for OPC UA clients:

Manual, 11/2024 93
You have configured a CPU as OPC UA client.

You have created a client interface in the client.

The client interface contains a read list with an array of which you want to read a part.

In the example, the client interface is called "Productionline" with the read list

"ReadListProduct":

The values in "Temperature[5]" to "Temperature[9]" are read from the "Temperature" array of

the server.

Providing additional information


"OPC_UA_ReadList" shows how to read out entire scalars (tags with a value) or arrays (tags with
multiple values) using the "OPC_UA_ReadList" instruction.
The following section provides additional details to "OPC_UA_ReadList" that are required for
using "OPC_UA_ReadList" to read part of an array.
OPC_UA_NodeAdditionalInfo
First create a local tag of the type "OPC_UA_NodeAdditionalInfo", see
"OPC_UA_NodeAdditionalInfo".
This tag is used to tell the "OPC_UA_ReadList" instruction which part of the array is to be read.
Proceed as follows:

1. Create an array tag of the type "OPC_UA_NodeAdditionalInfo".

In the example, the tag is created in the declaration section of the function block, which calls

the "OPC_UA_ReadList" instruction.

94 Manual, 11/2024
The new local tag is called "NodeAdditionalInformation":

The new local tag "NodeAdditionalInformation" contains three components of the type

OPC_UA_AdditionalInfo, because the read list "ReadListProduct" contains three nodes.

NodeAdditionalInformation[0] provides additional information on the first tag to be read (in

the example, "NewProduct")

NodeAdditionalInformation[1] provides additional information on the second tag to be read

(in the example, "ProductNumber")

NodeAdditionalInformation[2] provides additional information on the third tag to be read (in

the example, "Temperature")

2. Assign values to the new tag (in the "Default values" column of the declaration section).

In the example, the third tag (Temperature is partially read.

NodeAdditionalInformation[2].AttributeId is therefore assigned 13 (i.e. the values of the

array are read).

NodeAdditionalInformation[2].StartIndex is assigned a value of 5, as the reading starts at

(and includes) index 5.

NodeAdditionalInformation[2].EndIndex is assigned a value of 9, as the reading starts at (and

includes) index 9.

NodeAdditionalInformation[0] NodeAdditionalInformation[1] are set to default values.

The "#ignore" constant contains the value 4_294_967_295. The server ignores this value for

StartIndex and EndIndex and reads scalars and arrays completely.

Manual, 11/2024 95
Alternative:

You can also set the values for NodeAdditionalInformation in the user program:

// set additonal information to Array-Index 0

// we set default values here

#NodeAdditionalInformation[0].AttributeID := 13;

#NodeAdditionalInformation[0].StartIndex := 4_294_967_295;

#NodeAdditionalInformation[0].EndIndex := 4_294_967_295;

// set additonal information to Array-Index 1

// we set default values here

#NodeAdditonalInformation[1].AttributeID := 13;

#NodeAdditonalInformation[1].StartIndex := 4_294_967_295;

#NodeAdditonalInformation[1].EndIndex := 4_294_967_295;

// set additonal information to Array-Index 2

// because we want to read only five values from an array in

the OPC UA server

#NodeAdditonalInformation[2].AttributeID := 13;

#NodeAdditonalInformation[2].StartIndex := 5;

96 Manual, 11/2024
#NodeAdditonalInformation[2].EndIndex := 9;

Note:

The array NodeAdditionalInformation of the type "OPC_UA_NodeAdditionalInfo" must

contain as many components as the read list (3 in the example).

3. Assign NodeAdditionalInformation to the parameter "NodeAddInfos" of the instruction

"OPC_UA_ReadList".

The following figure shows the call of OPC_UA_ReadList with the new supply of the

"NodeAddInfos" parameter:

#OPC_UA_ReadList_Instance(REQ := #Req,

NodeHdls :=

"Productionline_Configuration".ReadLists."ReadListProduct".NodeHdls,

NodeStatusList :=

"myProductionline_Data"."ReadListProduct".NodeStatusList,

Variable :=

"myProductionline_Data"."ReadListProduct".Variable,

ConnectionHdl :=

"Productionline_Configuration".Connection.ConnectionHdl,

Timeout :=

"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,

NodeHdlCount :=

"Productionline_Configuration".ReadLists."ReadListProduct".NodeCount,

NodeAddInfos := #NodeAddtionalInformation,

TimeStamps :=

"myProductionline_Data".ReadListProduct.TimeStamps,

Done => #Done,

Busy => #Busy,

Error => #Error,

Status => #Status);

Manual, 11/2024 97
Result in the client
The "OP_UA_ReadList" instruction now reads only part of the "Temperature" array from the OPC
UA server.
The figure below shows the array "Temperature". The client assigns the read values as of Index 0:

Note
To read a section of a multi-dimensional array (up to six dimensions), use the
"OPC_UA_NodeAdditionalInfoExt" data type.

1.1.1.4.3 OPC_UA_WriteList: Write tags (S7-1500)

Validity
The following description of the "OPC_UA_WriteList" instruction applies to S7-1500 CPUs with
firmware version V2.6 and higher.

Description
You use the instruction "OPC_UA_WriteList" to write new values to PLC tags.
The following figure shows the icon of the instruction in the editor (FBD).

98 Manual, 11/2024
In the figure above, the parameters of the instruction are not supplied yet.
The instruction "OPC_UA_WriteList" is used to assign new values to PLC tags, see ② in the figure
below.
The instruction returns a list with status information for each PLC tag.

① Instructions for preparation of read and write operations

② Read and write instructions

③ Instructions for releasing resources after completed read or write operations

Parameters for OPC_UA_WriteList


The parameters of the instruction OPC_UA_WriteList

Parameters Declaration Data Meaning


in area type

REQ Input BOOL A rising edge 0 → 1 at the parameter


triggers execution of the instruction.

ConnectionHdl Input DWORD Unique identifier for a connection


established.
You get the handle from the instruction
OPC_UA_Connect: Create connection.

NodeHdlCount Input UINT Number of elements in the array that points


to the NodeHdls parameter.

NodeHdls InOut VARIANT Pointer to an array of the type DWORD.


The array contains the node handles of the
tags whose values are to be written.

Manual, 11/2024 99
The parameter is optional. If it is not set, the
value is set in all nodes (tags).
When writing arrays, you can limit which
elements of the array are to be written, see
Writing an array section with OPC_UA_WriteList.

Timeout Input TIME Maximum time for execution of the instruction


in milliseconds.
See also the explanation for this parameter in
OPC_UA_Connect: Create connection.

NodeStatusList InOut VARIANT Pointer to an array of the type DWORD.


The array contains the error codes for the
individual tags (see "Error numbers for
NodeStatusList" below).
Whether or not the value could be set is
indicated for each tag.
It is possible that the instruction was
successfully executed (Error parameter not set)
but a specific tag could not be assigned a value.
NodeStatusList[0] relates to NodeHdls[0], etc.

Variable InOut VARIANT Pointer to a tag that contains the values to be


written.
You must create a PLC data type (UDT) for this
tag.

Done Output BOOL Status of execution:

0: Execution of the instruction aborted, not

yet complete or not yet started

1: Execution of instruction completed

without errors

Busy Output BOOL Execution status parameter:

0: Instruction not being executed

1: Instruction currently being executed

Error Output BOOL Error display

0: No error

1: An error has occurred. See "Status"

parameter.

100 Manual, 11/2024


Status Output DWORD Cause of the error, see "Error numbers for Status" below

Error numbers for Status


The "Status" parameter provides information about errors that occurred during execution of the
instruction.
The following table shows a summary of error codes for this instruction:

Manual, 11/2024 101


The network load is too high.

The OPC UA server is not available.

Possible remedy:

Check the URL of the OPC UA


server

Increase the timeout setting


(higher value for the Timeout

parameter of the function block

OPC_UA_Connect).

800D_0000 OpcUa_BadServerNotConnected The server is not connected or the


connection handle is incorrect or
invalid.

800F_0000 OpcUa_BadNothingToDo Nothing to do: The OPC UA server


received an empty list with no
instructions from the OPC UA client.

8010_0000 OpcUa_BadTooManyOperations Number of "OPC_UA_WriteList"


instructions that can be called at the
same time per connection has been
exceeded (> 5), see: Number of client
instructions that can be used
simultaneously

80AE_0000 BadConnectionClosed The connection with the


corresponding ConnectionHdl is in
"ShutDown" status (connection
terminated). The connection/session
could not be "reactivated"
automatically. Possible cause: Session
deleted on the server, e.g. due to
restart or timeout).
In this case, you must explicitly close
the connection with the instruction
"OPC_UA_Disconnect" and release the
connection resources again. In your
user program, you must reset the
ConnectionHdl that has become
invalid for this connection.
Then you have to establish a new
connection to the server (see
instruction "OPC_UA_Connect").

80AF_0000 BadInvalidState The connection with the


corresponding ConnectionHdl is has

102 Manual, 11/2024


the "ConnectinError" status
(temporary connection error,
connection interrupted). The CPU
tries to "reactivate" the connection. If
this does not succeed in the set
timeout interval (OPC UA Session
Timeout), the connection goes into
the "Shutdown" state. Requirements
for the state transition: The CPU
could reach the OPC UA server to
check whether or not the session is
still active.

B080_0100 Simatic_BadType_VariantInput1 Incorrect data type for parameter


"NodeHdls".

B080_0200 Simatic_BadType_VariantInput2 Incorrect data type for parameter


"NodeAddInfos".

B080_0300 Simatic_BadType_VariantInput3 Incorrect data type for parameter


"NodeStatusList".

B080_0400 Simatic_BadType_VariantInput4 Incorrect data type for parameter


"Variable" (not UDT).

B080_1100 Simatic_ArrayElements_TooMany General error code. Occurs when an


array has too many elements.

B080_3100 BadNumElements_VariantInput1 The "NodeHdlCount" parameter is


greater than the number of ARRAY
elements in the "NodeHdls"
parameter.

B080_3200 BadNumElements_VariantInput2 The "NodeHdlCount" parameter is


greater than the number of ARRAY
elements in the "NodeAddInfos"
parameter.

B080_3300 BadNumElements_VariantInput3 The "NodeHdlCount" parameter is


greater than the number of ARRAY
elements in the "NodeStatusList"
parameter.

B080_3400 BadNumElements_VariantInput4 The PLC data type/structure for the


parameter "Variable" has too few or
too many elements as specified by
the value for the parameter
"NodeHdlCount".
Example: If "NodeHdlCount" has the
value 5, then the array "NodeHdls"
must also contain 5 elements. The

Manual, 11/2024 103


structure for the parameter "Variable" must
also consist of 5 elements.

B080_C400 Simatic_ClientNotEnabled The OPC UA client is disabled.

B080_C500 Simatic_NothingToDo Nothing to do: The instruction is using a list


that contains no elements.

C080_C300 Simatic_OutOfResources The maximum number of client instructions


that can be used at the same time has been
exceeded.
Possible remedy:

Reduce the number of client instructions

of the type running parallel, see:

Number of client instructions that can be


used simultaneously

For more error codes, see Error codes.

Error numbers for "NodeStatusList"


The "NodeStatusList" parameter contains an error code for each individual node handle (tag).
The following table explains the error codes:

Error code Name of the error Explanation


(hexadecimal
values)

0000_0000 OpcUa_Good Value successfully read.

8034_0000 OpcUa_BadNodeUnknown The node handle transferred


is not known.

8035_0000 OpcUa_BadAttributeInvalid The attribute required is not


supported for the specified
node.

8037_0000 OpcUa_BadIndexRangeNoD There is no data in the index


range.

8039_0000 OpcUa_BadDataEncodingUnsupported The OPC UA server does not


support the required data
decoding for this node.

104 Manual, 11/2024


803B_0000 OpcUa_BadNotWritable No rights for writing for this node.

803C_0000 OpcUa_BadOutOfRange The index value specified in the


NodeAddInfos parameter is outside the
permitted range.

803D_0000 OpcUa_BadNotSupported The OPC UA server does not support one


of the requested functions.
Some OPC UA servers do not allow access
to the index ranges of an array.

80AB_0000 OpcUa_BadInvalidArgument One or more arguments are invalid.

For more error codes, seeError codes.

This is how you use this instruction


Based on a program example, this section shows you how to use the instruction
"OPC_UA_WriteList" in a user program that sets new values in PLC tags.

Requirements
The following description assumes that:

You have created a client interface, see "Creating client interfaces".

You have created and configured a connection to an OPC UA server, see "Creating and

configuring connections".

If the CPU is to read and write structures in the OPC UA server as an OPC UA client: The

OPC UA server supports version V1.04 of the OPC UA specification.

The following requirements must also be met for the "OPC_UA_WriteList" instruction:

A handle for connection to an OPC UA server is available.

You get the connection handle from the instruction OPC_UA_Connect: Create connection.

Indexes of the namespaces that contain the tags that you want to write with the client.

You get the indexes from the instruction OPC_UA_NamespaceGetIndexList: Read namespace
indexes.

A list of the handles for the individual tags whose values you want to set in the OPC UA
server.

You get this handle list from the instruction OPC_UA_NodeGetHandleList: Get handles for
read and write access.

Manual, 11/2024 105


In the program example below, the instruction is called once to send an enable signal to the OPC
UA server.

Function of the block


You use the instruction "OPC_UA_WriteList" to write the values of tags in an OPC UA server.
What information is required?
The function requires the following information:

The handles for the tags whose values you want to write ("NodeHdls" parameter)

The values to be transferred for the individual tags ("Variable" parameter)

Refer to the following cases for this purpose:

- If you use a client interface with a write list, STEP 7 automatically creates a system data

type with the tags that need to be transferred.

- If you are not using a client interface, you must create a PLC data type (UDT) or a

structure (STRUCT) for the "Variable" parameter.

You define the components of this UDT according to the tags that have to be transferred.

Use the SIMATIC data type compatible with the respective OPC UA data type, see
Mapping SIMATIC data types to OPC UA data types.

What information does the instruction return?


The instruction returns the following information:

A list of error messages ("NodeStatusList" parameter).

Each error message in this list relates to the corresponding handle in the "NodeHdls"
parameter.

For each individual tag ("NodeHdl"), you need to check whether the OPC UA server was able
to accept the new value.

How to use a configured connection


1. In the "Project tree" area, select the CPU that acts as the client.

2. Select the function block that is to execute the client instruction in the "Program blocks"
folder.

In the example, the function block is called "WriteToProductionline".

Selected language: SCL.

3. Use drag-and-drop to move the instruction "OPC_UA_WriteList" from the folder "Instructions

> Communication > OPC UA > OPC UA Client" to the editor.

106 Manual, 11/2024


4. Select the call as multi-instance.

STEP 7 creates an instance of this instruction and calls it "OPC_UA_WriteList_Instance".

5. Click "OPC_UA_WriteList_Instance".

STEP 7 opens the "Configuration".

6. Under "Select client interface for OPC UA interface" you select the client interface that you

want to use for the instruction.

In the example, the client interface is named "Productionline",

(see Example configuration for OPC UA and "Creating client interfaces").

7. Click "Data access" and select a write list.

In the example, the read list is named "WriteListStatus".

STEP 7 now automatically supplies the parameters of the instruction with the values you
have configured for the client interface.

8. Click on "Block parameters" and assign tags manually to the remaining parameters REQ,
Busy, Done, Error, Status.

STEP 7 adds the selected tag to the function call.

Calling the instruction (initial call)


You can find the complete program in the section "Example program for writing PLC tags".
The program example uses the write list "WriteListStatus" which contains the following PLC tag:

ProductionEnabled

The program writes the new value of this tag to the server.
The section "Creating client interfaces" shows you how to create a client interface and how to
add a write list with PLC tags to it.
The example program is divided into multiple sections (cases) by a CASE instruction.
In the fourth program section, the tag values are written:

SCL

4: // case 4; write value to PLC variable "ProductionEnabled"


IF #SetProductionEnabled = TRUE THEN
#SetProductionEnabled := FALSE;
//set new value to true
"Productionline_Data"."WriteListStatus".Variable.ProductionEnabled
:= TRUE;
END_IF;

Manual, 11/2024 107


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
OPC_UA_WriteList_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeHdlCount :=
"Productionline_Configuration".WriteLists."WriteListStatus".NodeCount,
NodeHdls :=
"Productionline_Configuration".WriteLists."WriteListStatus".NodeHdls,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NodeStatusList :=
"Productionline_Data"."WriteListStatus".NodeStatusList,
Variable :=
"Productionline_Data"."WriteListStatus".Variable,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);

Asynchronous execution
The instruction "OPC_UA_WriteList" runs asynchronously to the user program and requires
multiple program cycles.
You can check the job status with the "Busy", "Done", "Error" and "Status" parameters.
Asynchronous program execution is described in the section "Difference between synchronous
and asynchronous instructions".

Explanation of the call of the instruction (initial call)


The example above shows case 4.
In the example program, this case only assigns one PLC tag a new value. In your application, you
can assign new values to a large number of PLC tags.
The new value is set to TRUE, if the "#SetProductionEnabled" tag contains the value "TRUE".
"#SetProductionEnabled" is then set to FALSE as the initialization is only to be run once (in the
first cycle).
The "OPC_UA_WriteList" instruction writes the new value to the PLC tag "ProductionEnabled" in
the OPC UA server.
If the instruction is not yet executed, #Busy is FALSE, so that the "#Req" tag is set to the value
TRUE. This starts the instruction. In the next cycle, #Req is FALSE.

108 Manual, 11/2024


Calling the instruction (troubleshooting)
The figure below shows evaluation of the "Done" and "Error" parameters.

SCL

IF #Done = TRUE THEN


FOR #i := 0 TO
UINT_TO_INT("Productionline_Configuration".WriteLists.WriteListStatus.No
- 1 DO
IF NOT ("Productionline_Data"."WriteListStatus".NodeStatusList
THEN
#Output_Error_Message := CONCAT_WSTRING(IN1 := WSTRING#'Error a
Writelist "WriteListStauts", Index: ',
IN2 := INT_TO_WSTRING(#i));
END_IF;
END_FOR;
#State := #State + 1;
END_IF;
IF #Error = TRUE THEN
#State := 100;
//In case 100, to set REG of instruction "OPC_UA_Disconnect" to FALS
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#OPC_UA_WriteList_Instance(REQ := FALSE,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeHdlCount :=
"Productionline_Configuration".WriteLists."WriteListStatus".NodeCount,
NodeHdls :=
"Productionline_Configuration".WriteLists."WriteListStatus".NodeHdls,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NodeStatusList :=
"Productionline_Data"."WriteListStatus".NodeStatusList,
Variable := "Productionline_Data"."WriteListStatus".Variab
END_IF;

Explanation of the call of the instruction (troubleshooting)


If an error occurs, the "Error" output parameter is set to the value TRUE. This sets the "#State" tag
to the value 100. This case is reserved for troubleshooting. The example program also calls the

Manual, 11/2024 109


"OPC_UA_WriteList" instruction to set the REQ parameter to FALSE.
If the output parameter "Done" is TRUE, the instruction was executed successfully.
Note: It is possible that the instruction was successfully executed ("Error" parameter not set,
"Done" parameter set) but no PLC tag could be set.
Therefore, there is a check in the example for the PLC tag to determine whether the program
was able to set a valid value:

If the server was able to assign the new value to the first PLC tag, the first element of the
array to which the "NodeStatusList" parameter is pointing contains the value 0.

In the example, only one tag is used. Your status code is available in
"Productionline_Data"."WriteListStatus".NodeStatusList[0]".

The program outputs an error message when a PLC tag could not be set.
The value of the "#State" tag is increased by 1. This means the next program section - case 5 -
(Release Handle List) is executed in the next cycle.
See also
OPC_UA_NodeId (S7-1500)
OPC UA instructions for client programs (S7-1500)
OPC_UA_NodeReleaseHandleList: Release handles for read and write access (S7-1500)

1.1.1.4.4 Writing an array section with OPC_UA_WriteList (S7-1500)

Introduction
This section is based on "OPC_UA_WriteList"; see OPC_UA_WriteList: Write tags.
The section describes how to assign new values to (write) a part of an array with the
"OPC_UA_WriteList" instruction.
Writing to a part of an array of an OPC UA server basically works as follows:

① Writing array elements to a part of an array of an OPC UA server

Requirements
The following description assumes that:

You have configured a CPU as OPC UA server.

110 Manual, 11/2024


The server provides an array that can be written by OPC UA clients.

In the example, you use the CPU "Productionline", which provides the data block

"Data_from_OPC_UA_Clients" for OPC UA clients:

You have configured a CPU as OPC UA client.

You have created a client interface in the client, see "Creating client interfaces".

The client interface contains a write list with an array.

Only a part of this array is to be used for writing the array on the server.

The example uses the client interface "Productionline" with the write list "WriteListStatus":

In the "Serial_Number" array of the server, new values are to be written to

"Serial_Number[5]" to "Serial_Number[9]".

Adapting write list data type and write list DB


"OPC_UA_WriteList" shows how to write new values to entire scalars (tags with a value) and
arrays (tags with multiple values) using the "OPC_UA_WriteList" instruction.
The following section provides additional details to "OPC_UA_WriteList" that are required for
using OPC_UA_WriteList to write new values to part of an array.
Step 1: Copying and adjusting write list data type
First, you change the data type of the tag that provides the values that you are writing to the
OPC UA server.
This change is required because the data type generated by STEP 7 is too long.
The data type is too long because you only want to assign new values to part of the array (and
not to the entire array).
In the example, you access the array "Serial_Number", which contains ten elements.

Manual, 11/2024 111


Proceed as follows to shorten this data type:

1. Open the "PLC data types" folder in the "Project tree".

2. Open the "System data types" folder.

3. Copy the data type "<client interface>.<write list>".

In the example, the data type is named ""Productionline.WriteListStatus".

4. Paste the copied data type to the "PLC data types" folder.

5. Change the name of the data type inserted so that it is meaningful in your project.

In the example, we are changing the name to "myUDTProductionline.WriteListStatus".

6. Change the data type of the array.

In the example, we want to write the values from Serial_Number[5] to Serial_Number[9] to


the OPC UA server.

We therefore shorten the data type from "Array[0..9] of Lint" to "Array[0..4] of Lintl".

In the example:

Step 2: Copy write list DB and apply new write list data type to it
In this step, you use the new data type in a new data block.
This step is required because the data block generated by STEP 7 contains the original data type
for the array.
It is not possible to change the data type: Each time the data block is compiled, the original data
type is restored. The changes are lost.
Proceed as follows to create a new data block:

1. In the "Project tree" area, select the CPU that acts as the client.

2. Open the "Program blocks" folder

3. Copy the data type <client interface>_Data

In the example, the data block is named "Productionline_Data"

4. Paste the copied data block to the "Program blocks" folder.

5. Change the name of the data block inserted so that it is meaningful in your project.

112 Manual, 11/2024


In the example, we change the name to "myProductionline_Data"

6. Now use the new data type that we created in Step 1.

In the example, we assign the new data type to the tag "Variable" in the write list

"WriteListStatus":

7. Supply the "Tag" parameter of the instruction "OPC_UA_WriteList" with the new data block
(in the example "myProductionline_Data").

Variable := "myProductionline_Data"."WriteListStatus".Variable,

Step 3: Create tag for OPC_UA_ReadList parameter "NodeAddInfos"


In this step, you create a local tag of the type "OPC_UA_NodeAdditionalInfo".
This tag is used to tell the "OPC_UA_WriteList" instruction which part of the array is to be
assigned new values.
Proceed as follows:

1. Create an array tag of the type "OPC_UA_NodeAdditionalInfo".

In the example, you create the tag in the declaration section of the function block that calls

the instruction "OPC_UA_WriteList".

You name the new local tag "NodeAdditionalInformation":

The new local tag "NodeAdditionalInformation" contains two elements of the type

"OPC_UA_AdditonalInfo".

Manual, 11/2024 113


NodeAdditionalInformation[0] provides additional information on the first tag to be written
(in the example, "ProductionEnabled")

NodeAdditionalInformation[1] provides additional information on the second tag to be


written (in the example, "Serial_Number")

2. Assign values to the new tag (in the "Default values" column of the declaration section).

In the example you do not write all elements of the second tag (Serial_Number).

You therefore assign NodeAdditionalInformation[1].AttributeId the value of 13 (which means

the values of the array are written).

NodeAdditionalInformation[1].StartIndex is assigned the value of 5, as you are writing from

(and including) index 5.

NodeAdditionalInformation[1].EndIndex is assigned the value of 9, as you are writing from

(and including) index 9.

You set the following values for NodeAdditionalInformation[0] which signal to the server that

the first element of the write list is not a part of an array but a scalar or an array that is to be

written completely.

The constant "#ignore" contains the value 4_294_967_295. The server ignores this value for

StartIndex and EndIndex and writes scalars and arrays completely.

Alternative:

You can also set the values for NodeAdditionalInformation in the user program:

// set additonal information to Array-Index 0

// we set default values here

#NodeAdditonalInformation[0].AttributeID := 13;

#NodeAdditonalInformation[0].StartIndex := 4_294_967_295;

114 Manual, 11/2024


#NodeAdditonalInformation[0].EndIndex := 4_294_967_295;

// set additonal information to Array-Index 1

// because we want to write only five values to the array in

the OPC UA server

#NodeAdditonalInformation[1].AttributeID := 13;

#NodeAdditonalInformation[1].StartIndex := 5;

#NodeAdditonalInformation[1].EndIndex := 9;

Note:

The array NodeAdditionalInformation of the type "OPC_UA_NodeAdditionalInfo" must

contain as many elements as the write list (2 in the example).

3. Assign the local tag NodeAdditionalInformation to the "NodeAddInfos" parameter of the

"OPC_UA_WriteList" instruction.

The following figure shows the call of OPC_UA_WriteList with the new supply of the

parameters "Variable" and "NodeAddInfos":

#OPC_UA_WriteList_Instance(REQ := #Req,

NodeHdls :=

"Productionline_Configuration".WriteLists."WriteListStatus".NodeHdls,

NodeStatusList :=

"myProductionline_Data"."WriteListStatus".NodeStatusList,

Variable :=

"myProductionline_Data"."WriteListStatus".Variable,

ConnectionHdl :=

"Productionline_Configuration".Connection.ConnectionHdl,

Timeout :=

"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,

NodeHdlCount :=

"Productionline_Configuration".WriteLists."WriteListStatus".NodeCount,

NodeAddInfos := #NodeAdditonalInformation,

Manual, 11/2024 115


Busy => #Busy,

Error => #Error,

Status => #Status,

Done => #Done);

Result in the server


The "OP_UA_WriteList" instruction now writes only part of the "Serial_Number" array to the OPC
UA server.
The figure below shows the array "Serial_Number". The server assigns the written values as of
the index that you specify with NodeAdditionalInformation (as of index 5 in the example):

Note
Use the data type "OPC_UA_NodeAdditionalInfoExt" to write to a section of a multi-dimensional
array (up to six dimensions).

1.1.1.4.5 Set OPC UA-DataValue with OPC_UA_WriteList (S7-1500)

Validity
The following description is valid for S7-1500 CPUs as of firmware version V3.0.

Requirements
You have activated the OPC UA server on your S7-1500 CPU.

116 Manual, 11/2024


Note
Set OPC UA-DataValue with OPC_UA_WriteList
The instruction "OPC_UA_WriteList" belongs to the OPC UA client instructions.
However, if you use it to set one or more OPC UA-DataValues on the OPC UA server
of the local CPU, it works independently of any client functionality. This means that
there is no handling of connections and the OPC UA client on your CPU does not
have to be activated. If you have activated it, the call of "OPC_UA_WriteList" used in
this way is not part of the client program.

Description
You may also use the instruction "OPC_UA_WriteList" under the above-mentioned conditions to
consistently overwrite the value and the associated additional information of one or more OPC
UA tag nodes on the OPC UA server of the local CPU (localhost connection).
For reasons of consistency, the tags nodes whose values are to be set locally must not be set by
a remote OPC UA client. Therefore, the "AccessLevel" or "UserAccessLevel" attributes of the
affected tag nodes must not have the "CurrentWrite" component.
The value including the associated additional information is referred to here as OPC UA-
DataValue.
The additional information is StatusCode, SourceTimestamp and SourcePicoseconds.
Only the data values of nodes from user-defined server interfaces can be set. The nodes must
not have any mapping to local data. Constants are overwritten.

Difference to the previous use of OPC_UA_WriteList


For S7-1500 CPUs with firmware version < V3.0, the instruction "OPC_UA_WriteList" can only be
used to write PLC tags of a remote OPC UA server. To do this, other instructions must be called
beforehand, including those to establish a connection. In addition, further instructions must be
called after the write operation to release resources again.
These preparations and post-processing are not necessary if you use the instruction
"OPC_UA_WriteList" to set one or more OPC UA-DataValues on the OPC UA server of the local
CPU. In this case, "OPC_UA_WriteList" works completely independently.
When using "OPC_UA_WriteList" to set OPC UA-DataValues on the OPC UA server of the local
CPU, some parameters have a different meaning than when writing PLC tags of a remote OPC UA
server. This is especially true for the "ConnectionHdl" parameter. With it you define how you
want to use the instruction.
The changed meaning of the parameters is explained in detail in the parameter table.

Functional description
The "OPC_UA_WriteList" instruction works asynchronously. Processing extends over multiple
calls. You start processing with a rising edge at the "Req" parameter.
The parameters "Busy" and "Done" indicate the status of the job.
If an error occurs during execution, this is signaled by the parameters "Error" and "Status".
See also: Difference between synchronous and asynchronous instructions

Parameters

Manual, 11/2024 117


The following table shows the parameters of the instruction "OPC_UA_WriteList" if you want to
use it to set one or more OPC UA-DataValues on the OPC UA server of the local CPU.

Parameter Declaration Data Description


type

Req Input Bool Control parameter Request


Activates the job on a positive edge.

ConnectionHdl Input DWord Note: This parameter has a different meaning


than when writing PLC tags of a remote OPC
UA server.
Decimal value -42 (16#FFFFFFD6)
This value causes "OPC_UA_WriteList" to set
OPC UA-DataValues on the OPC UA server of
the local CPU.

NodeHdlCount Input UINT Number of elements in the array pointed to


by the "NodeHdls" parameter.

NodeHdls InOut Variant Note: This parameter has a different meaning


than when writing PLC tags of a remote OPC
UA server.
Pointer to an array with elements of the
OPC_UA_NodeId type.
The array contains the node IDs of the OPC
UA tags whose values and additional
information are to be set. These are located
under the local server interfaces.

NoteAddInfos InOut Variant Note: This parameter has a different meaning


than when writing PLC tags of a remote OPC
UA server.
This parameter is not supported. It must be
ZERO or you do not interconnect it.

Timeout Input Time Note: This parameter has a different meaning


than when writing PLC tags of a remote OPC
UA server.
This parameter is not evaluated.

118 Manual, 11/2024


Done Output Bool Status parameter with the following values:

0: Job not yet started or still being processed.

1: Job completed without error. This state is

only displayed for one call.

Busy Output Bool Status parameter with the following values:

0: Job not yet started or already completed.

1: Job not yet completed. A new job with this


instance cannot be started.

Error Output Bool Status parameter

0: No error occurred.

1: Error occurred during processing.

The "Status" parameter provides detailed


information on the type of error. This state is only
displayed for one call.

Status Output DWord Return value or error information of the


"OPC_UA_WriteList" instruction, see below.

NodeStatusList InOut Variant Pointer to an array with elements of the DWord


type.
The array contains the error codes for the
individual OPC UA-DataValues, see below.
Each element indicates whether the OPC UA-
DataValue could be set successfully for the
associated NodeId. NodeStatusList is valid only if
Done is 1. Array elements whose index is >=
NodeHdlCount are invalid.

Tag InOut Variant Note: This parameter has a different meaning


than when writing PLC tags of a remote OPC UA
server.
Pointer to a structure or PLC data type (UDT) or to
an array of a structure or a PLC data type (UDT).
The pointer points to the OPC UA-DataValues to
be written.
The rules applicable to the OPC UA-DataValues are
described below.

You can find more information on valid data types under Overview of the valid data types

Rules for the OPC UA-DataValues

Manual, 11/2024 119


The OPC UA-DataValues must comply with the following rules:

Each OPC UA-DataValue is a structure or PLC data type (UDT) and consists of two, three or

four elements.

The first element always corresponds to the value of the OPC UA tags, addressed by their

node ID of the user-defined server interface. The data type of the first element can be any
valid data type. The "Union" data type is not supported.

See Data types for companion specifications

The elements two to four stand for the additional information StatusCode, SourceTimestamp

and SourcePicoseconds. Their order is arbitrary.

Only the data types DWORD, UINT and LDT (DATE_AND_LTIME) are permitted. Each data

type may only be present once.

Which element corresponds to which metadata is determined by the data type:

- An element of data type DWORD is interpreted as a status code.

If it does not exist or has the value 0, this is interpreted as the status code "Good".

If you preset the status code "Bad" (bit 31 set), the firmware of the CPU sets the value to

ZERO.

- An element of the LDT data type (DATE_AND_LTIME) is interpreted as SourceTimestamp.

If it does not exist or the value has LDT#1970-01-01-00:00:00.000000000 (preset value), it


is set to the current system time by the firmware of the CPU.

- An element of the UINT data type is interpreted as SourcePicoseconds.

If the element does not exist, it is interpreted as 0.

The numerical value of the element is not checked by the firmware of the CPU, which

means you are responsible for its default setting.

"Status" parameter
When the "Error" parameter has the value 1, you can use the "Status" parameter to determine
the cause of the error that occurred.
The following table contains the possible error codes.

Error code Name of the error Explanation


(16#...)

8003_0000 OpcUa_BadOutOfMemory The memory allocation during the


preparation of the call was not successful.

120 Manual, 11/2024


This may have several sporadic
causes.

8010_0000 OpcUa_BadTooManyOperations The number of "OPC_UA_WriteList"


instructions that can be called
simultaneously per connection has
been exceeded (max. 5).

B080_0100 Simatic_BadType_VariantInput1 Incorrect data type for the


"NodeHdls" parameter

B080_0200 Simatic_BadType_VariantInput2 A value has been assigned to the


"NoteAddInfos" parameter.

B080_0300 Simatic_BadType_VariantInput3 Incorrect data type for the


"NodeStatusList" parameter

B080_0400 Simatic_BadType_VariantInput4 Incorrect data type for the "Tag"


parameter

B080_1100 Simatic_ArrayElements_TooMany NodeHdlCount >


MAX_ELEMENTS_NODELIST (300)

B080_C300 Simatic_InsufficientResources The OPC UA server cannot be


reached, for example, due to
insufficient memory space.

B080_C500 Simatic_NothingToDo NodeHdlCount has the value 0.

B080_C700 Simatic_ServerNotEnabled The OPC UA server is not activated.

B080_C800 Simatic_ServerNotAvailable The OPC UA server is activated but


not yet available.

B080_C900 Simatic_ServerNotInitialized The OPC UA server is activated and


available but not yet initialized.

"NodeStatusList" parameter
Each element in the "NodeStatusList" parameter indicates whether the data value for the
associated NodeId could be set successfully.
The following table explains the error codes.

Error code Name of the error Explanation


(16#...)

8003_0000 OpcUa_BadOutOfMemory The memory allocation during the


preparation of the call was not

Manual, 11/2024 121


successful. This may have several sporadic
causes.

8034_0000 OpcUa_BadNodeIdUnknown The OPC_UA_NodeId points to a node that


does not exist with this NamespaceIndex
in the address space of the server.

803B_0000 OpcUa_BadNotWritable The OPC_UA_NodeId points to a


ServerInterface node that is defined with
the property "writable for an OPC UA
client".

803D_0000 OpcUa_BadNotSupported The OPC UA DataValue for this NodeId


cannot be changed. Possible causes:

The OPC_UA_NodeId refers to a


ServerInterface node that is assigned

to a PLC tag.

The OPC_UA_NodeId is part of

namespace 3 (standard SIMATIC server

interface)

The OPC_UA_NodeId is part of

namespace 0.

The OPC_UA_NodeId does not

correspond to a ServerInterface node

or is not a tag.

803E_0000 OpcUa_BadNotFound The NamespaceIndex in the


OPC_UA_NodeId could not be resolved.

8074_0000 OpcUa_BadTypeMismatch The data type of the element "Value" in


the provided OPC UA-DataValue does not
match the data type of the associated
node.

B080_2400 BadValue_VariantInput4 The definition of the OPC UA DataValue in


the corresponding element of the "Tag"
parameter is incorrect. It does not satisfy
the rules for OPC UA DataValues described
above.

Good-Overload Scenario
An OPC UA server can transmit the status code "GoodOverload" when using subscriptions if an
overload of the CPU occurs while sampling the items. See Subscription diagnostics

122 Manual, 11/2024


If the OPC UA server of the local CPU uses subscriptions, you must consider this when setting
OPC UA-DataValues by means of OPC_UA_WriteList.
If you have set a status code with the property "Severity = Good" with OPC_UA_WriteList, it will
always be overwritten by the status code "GoodOverload". After the end of the CPU overload,
the status code applies the last value that you set with OPC_UA_WriteList. A status code with the
property "Severity = Bad" or "Severity = Uncertain" is not changed by "GoodOverload".
Bits 14 "SemanticsChanged" and 15 "StructureChanged" are set in case of "GoodOverload".
Likewise, the overflow bit can be set on "GoodOverload".

More information
An application example provides additional support on the topic "Set OPC UA-DataValues on the
OPC UA server of the local CPU": Setting OPC UA DataValue attributes
See also
Client accesses and local accesses to the OPC UA server (S7-1500, S7-1500T)

1.1.1.5 Ending data exchange (S7-1500)

1.1.1.5.1 OPC_UA_NodeReleaseHandleList: Release handles for read and write access (S7-1500)

Validity
The following description of the "OPC_UA_NodeReleaseHandleList" instruction applies to S7-
1500 CPUs with firmware version V2.6 and higher.

Description
You use the instruction "OPC_UA_NodeReleaseHandleList" to release handles.
The following figure shows the icon of the instruction in the editor (FBD).

In the figure above, the parameters of the instruction are not supplied yet.
The instruction "OPC_UA_NodeReleaseHandleList" is used to release handles for PLC tags that
were previously registered with the instruction "OPC_UA_NodeGetHandleList", see ③ in the
figure below.

Manual, 11/2024 123


The instruction "OPC_UA_NodeReleaseHandleList" is not required when you want to disconnect
the connection to the OPC UA server. In this case, call the "OPC_UA_Disconnect: Close the
connection" instruction immediately. This instruction automatically releases all handles.

① Instructions for preparation of read and write operations

② Read and write instructions

③ Instructions for releasing resources after completed read or write operations

Parameters for "OPC_UA_NodeReleaseHandleList"


The parameters of the function block "OPC_UA_NodeReleaseHandleList"

Parameters Declaration S7 data Meaning


in area type

REQ Input BOOL A rising edge 0 → 1 at the parameter


triggers execution of the block.

ConnectionHdl Input DWORD Unique identifier for a connection


established: Connection handle.
You get the connection handle by calling
the function block OPC_UA_Connect.

NodeHdlCount Input UINT Number of elements in the NodeHdls


parameter

NodeHdls InOut VARIANT Pointer to an array of the type DWORD.


The array contains the handles for the tags
that you no longer want to read or set in
your program.

Timeout Input TIME Maximum time for execution of the


function block.
See also the explanation for this parameter
in OPC_UA_Connect: Create connection.

NodeStatusList InOut VARIANT Pointer to an array of the type DWORD.


The array contains the error codes for the
individual node handles (tags); see "Error

124 Manual, 11/2024


numbers in the NodeStatusList parameter".
For each node handle, you can see whether or not it could
be released.

Done Output BOOL Status parameter for block processing

0: Block processing aborted, not yet completed or not

yet started

1: Block processing completed without errors

Busy Output BOOL Status parameter for block processing

0: Block not being executed

1: Block currently being executed

Error Output BOOL Error display

0: No error

1: An error has occurred. See "Status" parameter.

Status Output DWORD see "Error numbers in the Status parameter" below

Error numbers for Status


The following table shows a summary of error codes for this instruction:

Error code Name of the error Explanation


(hexadecimal
values)

0000_0000 OpcUa_Good Function block executed


successfully.

0070_0000 - First call without rising edge at


REQ, which means job execution is
not started

0070_0100 - First call with start of job execution

0070_0200 - Subsequent call

8003_0000 OpcUa_BadOutOfMemory No memory available for the OPC


UA client.
As the OPC UA client and OPC UA
server share a memory area, you

Manual, 11/2024 125


should reduce the memory
requirement of the server.
You have the following options:

Release fewer PLC tags for OPC

UA.

Reduce the number of OPC UA

clients that are currently connected

to the server.

Set up fewer subscriptions.

800A_0000 OpcUa_BadTimeout A network timeout occurred.


Possible causes:

Connection to the OPC UA server


is too slow (insufficient capacity)

The network load is too high.

The OPC UA server is not available.

Possible remedy:

Check the URL of the OPC UA


server

Increase the timeout setting


(higher value for the Timeout

parameter of the function block

OPC_UA_Connect).

800D_0000 OpcUa_BadServerNotConnected The server is not connected or the


connection handle is incorrect or
invalid.

800F_0000 OpcUa_BadNothingToDo Nothing to do: The OPC UA server


received an empty list with no
instructions from the OPC UA client.

8010_0000 OpcUa_BadTooManyOperations Number of


"OPC_UA_NodeReleaseHandleList"
instructions that can be called at the
same time per connection has been
exceeded (> 1), see: Number of client
instructions that can be used
simultaneously

126 Manual, 11/2024


80AE_0000 BadConnectionClosed The connection with the
corresponding ConnectionHdl is in
"ShutDown" status (connection
terminated). The connection/session
could not be "reactivated"
automatically. Possible cause: Session
deleted on the server, e.g. due to
restart or timeout).
In this case, you must explicitly close
the connection with the instruction
"OPC_UA_Disconnect" and release the
connection resources again. In your
user program, you must reset the
ConnectionHdl that has become
invalid for this connection.
Then you have to establish a new
connection to the server (see
instruction "OPC_UA_Connect").

80AF_0000 BadInvalidState The connection with the


corresponding ConnectionHdl is has
the "ConnectinError" status
(temporary connection error,
connection interrupted). The CPU
tries to "reactivate" the connection. If
this does not succeed in the set
timeout interval (OPC UA Session
Timeout), the connection goes into
the "Shutdown" state. Requirements
for the state transition: The CPU
could reach the OPC UA server to
check whether or not the session is
still active.

B080_0100 Simatic_BadType_VariantInput1 Incorrect data type for parameter


"NodeHdls".

B080_1100 Simatic_ArrayElements_TooMany NodeHdlCount >


MAX_ELEMENTS_NODELIST

B080_0200 Simatic_BadType_VariantInput2 Incorrect data type for parameter


"NodeStatusList".

B080_3100 BadNumElements_VariantInput1 NodeHdlCount > Number of array


elements of the "NodeHdls"
parameter.

B080_3200 BadNumElements_VariantInput2 NodeHdlCount > Number of array


elements of the "NodeStatusList"
parameter.

Manual, 11/2024 127


B080_C400 Simatic_ClientNotEnabled The OPC UA client is disabled.

B080_C500 Simatic_NothingToDo Nothing to do: The instruction is using a list


that contains no elements.

C080_C300 Simatic_OutOfResources The maximum number of client instructions


that can be used at the same time has been
exceeded.
Possible remedy:

Reduce the number of client instructions

of the type running parallel, see:

Number of client instructions that can be


used simultaneously

For more error codes, see Error codes.

Error numbers for "NodeStatusList"


The "NodeStatusList" parameter contains an error code for each individual node handle (tag).
The following table explains the error codes:

Error code Name of the error Explanation


(hexadecimal
values)

0000_0000 OpcUa_Good Handle released successfully.

8034_0000 OpcUa_BadNodeUnknown The node handle transferred is


not known.

For more error codes, see Error codes.

This is how you use this instruction


Based on a program example, this section shows you how to use the instruction
"OPC_UA_NodeReleaseHandleList" in a program that exchanges data with an OPC UA server.

Requirements
The following description assumes that:

You have created a client interface.

You have created and configured a connection to an OPC UA server, see "Creating and

configuring connections".

128 Manual, 11/2024


In addition, the following requirements must be met for the instruction
"OPC_UA_NodeReleaseHandleList":

A handle for connection to an OPC UA server is available.

You get the connection handle by calling the function block "OPC_UA_Connect: Create

connection".

A list of the handles for the individual tags whose values you no longer want to read or write

in your program.

You get this handle list by calling the function block "OPC_UA_NodeGetHandleList: Get

handles for read and write access".

Function of the instruction


You call the instruction "OPC_UA_NodeReleaseHandleList" to release node handles that you no
longer require in your program.
Node handles are numeric references to nodes (for example PLC tags) on the OPC UA server.
What information is required for the function block?
The function block requires the following information:

A list of the handles for the tags (or other nodes) whose values you no longer want to read
or write (in the "NodeHdls" parameter).

What information does the function block return?


The function block returns the following information:

A list of error messages (in the "NodeStatusList" parameter).

Each error message in this list relates to the corresponding handle in the "NodeHdls"

parameter.

For each individual node handle, you need to check whether the OPC UA server was able to

release it.

If a node handle could not be released, you user program must catch this error: For example,

call this instruction once again in a troubleshooting session.

How to use a configured connection


1. In the "Project tree" area, select the CPU you want to use as a client.

2. Select the function block that is to execute the client instruction in the "Program blocks"

folder.

In the example, the function block is called "ReadFromProductionline".

Selected language: SCL.

Manual, 11/2024 129


3. Use drag-and-drop to move the instruction "OPC_UA_NodeReleaseHandleList" from the
folder "Instructions > Communication > OPC UA > OPC UA Client" to the editor.

4. Select the call as multi-instance.

STEP 7 creates an instance of this instruction and calls it

"OPC_UA_NodeReleaseHandleList_Instance".

5. Click on the icon for "Start configuration" at the "OPC_UA_NodeReleaseHandleList_Instance"

instruction.

STEP 7 opens the "Configuration" tab in the Inspector window.

6. Under "Select client interface for OPC UA interface" you select the client interface that you

want to use for the instruction.

In the example, the client interface is called "Productionline", which we created for our

Example configuration for OPC UA.

7. Click "Data access" and select a read list.

In the example, the read list "ReadListProduct".

STEP 7 now automatically supplies the parameters of the instruction with the values you

have configured for the client interface.

8. Click on "Block parameters" and assign tags manually to the parameters REQ, Busy, Done,

Error, Status.

STEP 7 adds the selected tag to the function call.

Calling the instruction (initial call)


You can find the complete program in the section "Program example for reading PLC tags".
The program example uses the read list "ReadListProduct", which contains the following PLC
tags:

NewProduct

ProductNumber

The handles for these PLC tags are released by the following program example.
CASE instruction
The example program is divided into multiple sections (cases) by a CASE instruction.
Case 5 is shown here:

SCL

5: // case 5, release node handles

130 Manual, 11/2024


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;

#OPC_UA_NodeReleaseHandleList_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeHdlCount :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeCount,
NodeHdls :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeHdls,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NodeStatusList :=
"Productionline_Data"."ReadListProduct".NodeStatusList,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);

Asynchronous execution
The instruction "OPC_UA_NodeReleaseHandleList" runs asynchronously to the user program and
requires multiple program cycles.
You can check the job status with the "Busy", "Done", "Error" and "Status" parameters.
Asynchronous program execution is described in the section "Difference between synchronous
and asynchronous instructions".

Explanation of the call of the instruction (initial call)


The figure above shows case 5.
This part of the program calls the instruction "OPC_UA_NodeReleaseHandleList". This releases
handles for PLC tags. The tags are listed in the "ReadListProduct" read list.
If the instruction is not yet executed, #Busy is FALSE, so that the "#Req" tag is set to the value
TRUE. This starts the instruction. In the next cycle, #Req is FALSE.

Calling the instruction (troubleshooting)


The figure below shows evaluation of the "Done" and "Error" parameters.

SCL

Manual, 11/2024 131


IF #Done = TRUE THEN
IF "Productionline_Data"."ReadListProduct".NodeStatusLis
= 0 AND
"Productionline_Data"."ReadListProduct".NodeStatusLis
= 0
THEN
#State := #State + 1;
ELSE
#State := 100;
//In case 100, to set REQ of instruction
"OPC_UA_Disconnect" to FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#Output_Error_Message := WString#'Error at
NodeReleaseHandleList';
END_IF;
END_IF;

IF #Error = TRUE THEN


#State := 100;
//In case 100, to set REG of instruction "OPC_UA_Disconn
to FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#OPC_UA_NodeReleaseHandleList_Instance(REQ := FALSE,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeHdlCount :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeCount,
NodeHdls :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeHdls,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NodeStatusList :=
"Productionline_Data"."ReadListProduct".NodeStatusList);
END_IF;

Explanation of the call of the instruction (troubleshooting)

132 Manual, 11/2024


If an error occurs, the "Error" output parameter is set to the value TRUE. This sets the #State tag
to the value 100. This case is reserved for troubleshooting. The example program also calls the
instruction "OPC_UA_NodeReleaseHandleList" to set the REQ parameter to FALSE.
If the TRUE value is in the "Done" output parameter, the instruction was successfully executed.
Note: It is possible that the instruction was successfully executed ("Error" parameter not set,
"Done" parameter set) but a handle could not be released for a PLC tag.
Therefore, there is a check in the example to determine whether the handles for both tags have
been released:

If the server releases the handle for the first PLC tag, the first element of the array to which
the "NodeStatusList" parameter is pointing contains the value 0.

In the example, the status code is available in


"Productionline_Data"."ReadListProduct".NodeStatusList[0].

If the server releases the handle for the second PLC tag, the second element of the array to
which the "NodeStatusList" parameter is pointing contains the value 0.

In the example, the status code is available in


"Productionline_Data"."ReadListProduct".NodeStatusList[1].

If both conditions are met, the value of tag "#State" is increased by one. This means the next
program section - case 6 (close connection) - is executed in the next cycle.
Case 6 is described in OPC_UA_Disconnect: Close the connection.

Note
Case 6 is for enabling the connection to the OPC UA server. This also releases all
other resources that the client program has occupied in the server. If you want to
terminate the connection to the server, your user program can execute case 6
immediately and skip case 5.

See also
OPC_UA_NamespaceGetIndexList: Read namespace indexes (S7-1500)
OPC UA instructions for client programs (S7-1500)
Example programs for OPC UA clients (S7-1500)

1.1.1.5.2 OPC_UA_Disconnect: Close the connection (S7-1500)

Validity
Unless otherwise specified, the following description of the "OPC_UA_Disconnect" instruction
applies to S7-1500 CPUs with firmware version V2.6 and higher.

Description
You use the instruction "OPC_UA_Disconnect" to disconnect the connection to a OPC UA server.

Note

Manual, 11/2024 133


Handling of connection handles (ConnectionHdl) as of firmware version V2.8
As of firmware version V2.8, after a connection error (error code
"BadConnectionClosed"), you must explicitly close the connection with the
instruction "OPC_UA_Disconnect" and thus release the connection resources again.
You must reset the ConnectionHdl for this invalid connection in your user program.

The following figure shows the icon of the instruction in the editor (FBD).

In the figure above, the parameters of the instruction are not supplied yet.
The instruction "OPC_UA_Disconnect" is used to disconnect the connection to an OPC UA server
and terminate the session, see ③ in the figure below:

① Instructions for preparation of read and write operations

② Read and write instructions

③ Instructions for releasing resources after completed read or write operations

Parameters for "OPC_UA_Disconnect"


The parameters of the function block "OPC_UA_Disconnect"

Parameters Declaration Data Meaning


in area type

REQ Input BOOL A rising edge 0 → 1 at the parameter triggers


execution of the block.

134 Manual, 11/2024


ConnectionHdl Input DWORD Unique identifier for a connection established:
Connection handle.
You get the connection handle by calling the
function block OPC_UA_Connect.

Timeout Input TIME Maximum time for execution of the function


block.
See also the explanation for this parameter in
OPC_UA_Connect: Create connection.

Done Output BOOL Status parameter for block processing

0: Block processing aborted, not yet

completed or not yet started

1: Block processing completed without errors

Note: Even if the processing of the


"OPC_UA_Disconnect" instruction is finished with
Done=1, the connection resource remains
occupied for about 60 seconds, see Details about
OPC UA client/server connections.

Busy Output BOOL Status parameter for block processing

0: Block not being executed

1: Block currently being executed

Error Output BOOL Error display

0: No error

1: An error has occurred. See "Status"

parameter.

Status Output DWORD see "Error numbers in the Status parameter"


below

Error numbers in the Status parameter


The "Status" parameter provides information about errors that occurred during execution of the
instruction.

Error code Name of the error Explanation


(hexadecimal
values)

Manual, 11/2024 135


0000_0000 OpcUa_Good Function block executed successfully.

0070_0000 - First call without rising edge at REQ,


which means job execution is not
started

0070_0100 - First call with start of job execution

0070_0200 - Subsequent call

8003_0000 OpcUa_BadOutOfMemory No memory available for the OPC UA


client.
As the OPC UA client and OPC UA
server share a memory area, you
should reduce the memory
requirement of the server.
You have the following options:

Release fewer PLC tags for OPC

UA.

Reduce the number of OPC UA

clients that are currently connected

to the server.

Set up fewer subscriptions.

800A_0000 OpcUa_BadTimeout A network timeout occurred.


Possible causes:

Connection to the OPC UA server


is too slow (insufficient capacity)

The network load is too high.

The OPC UA server is not available.

Possible remedy:

Check the URL of the OPC UA


server

Increase the timeout setting


(higher value for the Timeout

parameter of the function block

OPC_UA_Connect).

136 Manual, 11/2024


invalid.

800F_0000 OpcUa_BadNothingToDo Nothing to do: The OPC UA server


received an empty list with no
instructions from the OPC UA client.

8010_0000 OpcUa_BadTooManyOperations Number of "OPC_UA_Disconnect"


instructions that can be called at the
same time per connection has been
exceeded (> 1), see: Number of client
instructions that can be used
simultaneously

B080_C400 Simatic_ClientNotEnabled The OPC UA client is disabled.

B080_C600 Simatic_ClientNotAvailable Error during initialization of the client

C080_C300 Simatic_OutOfResources The maximum number of client


instructions that can be used at the
same time has been exceeded.
Possible remedy:

Reduce the number of client

instructions of the type running

parallel, see: Number of client


instructions that can be used

simultaneously

For more error codes, see Error codes.

This is how you use this instruction


Based on a program example, this section shows you how to use the instruction
"OPC_UA_Disconnect" in a program that exchanges data with an OPC UA server.

Requirements
The following description assumes that:

You have created a client interface, see "Creating client interfaces".

You have created and configured a connection to an OPC UA server, see "Creating and

configuring connections".

In addition, the following requirement must be met for the instruction "OPC_UA_Disconnect":

A handle for connection to an OPC UA server is available.

Manual, 11/2024 137


You get the connection handle by calling the instruction, see OPC_UA_Connect: Create
connection.

Function of the instruction


You call the instruction "OPC_UA_Disconnect" to disconnect the connection to an OPC UA server.

How to use a configured connection


1. In the "Project tree" area, select the CPU you want to use as a client.

2. Select the function block that is to execute the client instruction in the "Program blocks"
folder.

In the example, the function block is called "ReadFromProductionline".

Selected language: SCL.

3. Use drag-and-drop to move the instruction "OPC_UA_Disconnect" from the folder

"Instructions > Communication > OPC UA > OPC UA Client" to the editor.

4. Select the call as multi-instance.

STEP 7 creates an instance of this instruction and calls it "OPC_UA_Disconnect_Instance".

5. Click on the icon for "Start configuration" at the "OPC_UA_Disconnect_Instance" instruction.

STEP 7 opens the "Configuration" tab in the Inspector window.

6. Under "Select client interface for OPC UA interface" you select the client interface that you
want to use for the instruction.

In the example, the client interface is called "Productionline", which was created for the
Example configuration for OPC UA, see "Creating client interfaces".

STEP 7 now automatically supplies the parameters of the instruction with the values you
have configured for the client interface.

7. Click on "Block parameters" and assign tags manually to the remaining parameters REQ,
Busy, Done, Error, Status.

STEP 7 adds the selected tag to the call of the instruction.

Calling the instruction


You can find the complete program in the section "Program example for reading PLC tags".
The example program terminates the connection to an OPC UA server and the session:

SCL

138 Manual, 11/2024


6: // case 6, disconnect from server
IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_Disconnect_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);

The example program calls the "OPC_UA_Disconnect" instruction for the following reasons:

To terminate the connection to the OPC UA server.

To set the REQ parameter to FALSE, if an error has occurred.

Asynchronous execution
The instruction "OPC_UA_Disconnect" runs asynchronously to the user program and requires
multiple program cycles.
You can check the job status with the "Busy", "Done", "Error" and "Status" parameters.
Asynchronous program execution is described in the section "Difference between synchronous
and asynchronous instructions".

Explanation of the call of the instruction


The figure above shows case 6. This part of the program terminates the connection to the
connected OPC UA server and the session.
If the #State tag is 6, then case 6 is executed.
If the "OPC_UA_Disconnect" instruction is not yet executed, #Busy is FALSE, so that the "#Req"
tag is set to the value TRUE. This starts the instruction. In the next cycle, #Req is FALSE.
If the output parameter "Done" is TRUE, the handle for the connection could be released and the
connection could be terminated. This increases the value of the "#State" tag by one. This means
the next program section - case 7 - is executed in the next cycle. This case sets the status
information for the function block (Output_Busy = FALSE, Output_Done = TRUE).
If the instruction cannot be executed without errors, the output parameter "Error" is TRUE and
the tag #State gets the value 100. This case is reserved for troubleshooting.

1.1.1.6 Diagnostics (S7-1500)

Manual, 11/2024 139


1.1.1.6.1 OPC_UA_ConnectionGetStatus: Read connection status (S7-1500)

Validity
Unless otherwise specified, the following description of the "OPC_UA_ConnectionGetStatus"
instruction applies to S7-1500 CPUs with firmware version V2.6 and higher.

Description
You use the instruction "OPC_UA_ConnectionGetStatus" to monitor a connection, i.e. to get
information about the quality of the connection to an OPC UA server.
The instruction returns the following information:

Status of the connection

Status and service level of the connected OPC UA server

(Node identifier of status: i=2259, node identifier of ServiceLevel: i=2267)

① Instructions for preparation of read and write operations

② Read and write instructions

③ Instructions for "clean-up" after a completed read or write operation

Parameters for "OPC_UA_ConnectionGetStatus"


The parameters of the function block "OPC_UA_ConnectionGetStatus"

Parameters Declaration Data Meaning


in area type

REQ Input BOOL A rising edge 0 → 1 at the parameter


triggers execution of the instruction.

ConnectionHdl Input DWORD Unique identifier for a connection


established.
You get the handle from the instruction
OPC_UA_Connect: Create connection.

140 Manual, 11/2024


Timeout Input TIME Maximum time for execution of the instruction
in milliseconds.
See also the explanation for this parameter in
OPC_UA_Connect: Create connection.

Done Output BOOL Status of execution:

0: Execution of the instruction aborted, not


yet complete or not yet started

1: Execution of instruction completed


without errors

Busy Output BOOL Execution status parameter:

0: Instruction not being executed

1: Instruction currently being executed

Error Output BOOL Error display

0: No error

1: An error has occurred. See "Status"

parameter.

Status Output DWORD Cause of the error, see "Error numbers for
Status" below

ConnectionStatus Output UDINT Status of the connection that is identified by


the ConnectionHdl parameter.
Valid when Done=1.
Meaning:

0: Connection to the OPC UA server has

been established.

1: Incorrect connection to the OPC UA

server ("ConnectionError"). In this state, the

CPU tries to "reactivate" the connection.

2: The connection to the OPC UA server

could not be reactivated. The CPU has


disconnected from the server

("ShutDown"). You have to close the

connection (OPC_UA_Disconnect) and then

Manual, 11/2024 141


establish a new connection to the OPC UA server

(OPC_UA_Connect).

ServerState Output UDINT Information about the OPC UA server. Valid when
Done=1 and ConnectionStatus=0
Meaning of the values:

0: The server is running normally.

1: An error has occurred in the server. The server

is no longer operating reliably.

2: The server is running. However, no

configuration has been loaded and data is

therefore not being exchanged.

3: The server is temporarily unavailable.

4: The server has been or is in the process of

being shut down.

5: The server is running in test mode. Outputs are

not interconnected.

6: The server is running normally. However, there

are problems with reading the PLC tags.

7: Server status is not known.

This value is set if there is no connection to the


server.

ServiceLevel Output Byte Information on the power of the connected OPC UA


server. Valid when Done=1 and ConnectionStatus=0.
The server returns a number between 0 and 255 to
indicate its power: The higher the number, the more
powerful the server.

Error numbers for Status


The "Status" parameter provides information about errors that occurred during execution of the
instruction.
The following table shows a summary of error codes for this instruction:

Error code

142 Manual, 11/2024


(hexadecimal Name of the error Explanation
values)

0000_0000 OpcUa_Good Instruction finished successfully.

0070_0000 - First call without rising edge at REQ,


which means job execution is not
started

0070_0100 - First call with start of job execution

0070_0200 - Subsequent call

8003_0000 OpcUa_BadOutOfMemory No memory available for the OPC UA


client.
As the OPC UA client and OPC UA
server share a memory area, you
should reduce the memory
requirement of the server.
You have the following options:

Release fewer PLC tags for OPC

UA.

Reduce the number of OPC UA

clients that are currently


connected to the server.

Set up fewer subscriptions.

8009_0000 OpcUa_BadUnknownResponse The server sends an unknown or


invalid response.

Manual, 11/2024 143


Increase the timeout setting
(higher value for the

Timeout parameter of the

function block
OPC_UA_Connect).

800D_0000 OpcUa_BadServerNotConnected The server is not connected or


the connection handle is
incorrect or invalid.

8010_0000 OpcUa_BadTooManyOperations Number of


"OPC_UA_ConnectionGetStatus"
instructions that can be called
at the same time per
connection has been exceeded
(> 1), see: Number of client
instructions that can be used
simultaneously

8074_0000 OpcUa_BadTypeMismatch ServerState / ServiceLevel have


unexpected type.

A000_0105 PLCopenUA_Bad_ConnectionInvalidHdl The connection handle


(ConnectionHdl) is invalid /
unknown. You need to
establish a new connection.
When a connection is released
with the "OPC_UA_Disconnect"
instruction, the Connection
Handle for this connection also
becomes invalid. Note: For S7-
1500 CPUs as of firmware
version V2.8, the connection
handle is only released or
invalid when the
OPC_UA_Disconnect instruction
is called.

B080_C400 Simatic_ClientNotEnabled The OPC UA client is disabled.

C080_C300 Simatic_OutOfResources The maximum number of client


instructions that can be used at
the same time has been
exceeded.
Possible remedy:

Reduce the number of client


instructions of the type

144 Manual, 11/2024


running parallel, see: Number of client instructions that can be used

simultaneously

For more error codes, see Error codes.

Requirement
The following requirement must be met for the instruction "OPC_UA_ConnectionGetStatus":

A handle for connection to an OPC UA server is available.

You get the connection handle from the instruction OPC_UA_Connect: Create connection.

Calling the instruction


This section describes the function block "Analyze_Connection". The function block shows you
how to use the instruction "OPC_UA_ConnectionGetStatus".
You can find the complete example in the section "Example program for
OPC_UA_ConnectionGetStatus".
Declaration of tags
Declare an instance of the instruction "OPC_UA_ConnectionGetStatus" and the tags with which
you are supplying the instruction parameters.
The program example uses the following declaration:

User program
The figure below shows the section from the example program "Analyze_Connection" that
determines the quality of the connection to the server.
The example program is divided into multiple sections (cases) by a CASE instruction.
Case 2 (analysis of the connection) is shown here:

SCL

2: // case 2, analyse connection


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_ConnectionGetStatus_Instance(REQ := #Req,
ConnectionHdl := #ConnectionHdl,

Manual, 11/2024 145


Timeout := T#6S,
Done => #Done,
Error => #Error,
Busy => #Busy,
Status => #Status,
ConnectionStatus => #ConnectionStatus,
ServerState => #ServerState,
ServiceLevel => #ServiceLevel);
IF #Done = TRUE THEN
#State := #State + 1;
END_IF;
IF #Error = TRUE THEN
#State := 100;
#Mem_Status := #Status;
#OPC_UA_ConnectionGetStatus_Instance(REQ :=
FALSE, ConnectionHdl := #ConnectionHdl);
END_IF;
If an error occurs, the instruction "OPC_UA_ConnectionGetStatus" (#Error has the value "TRUE"),
the parameter REQ is set to the value FALSE.
Asynchronous execution
The instruction "OPC_UA_ConnectionGetStatus" runs asynchronously to the user program and
requires multiple program cycles.
You can check the job status with the "Busy", "Done", "Error" and "Status" parameters.
Asynchronous program execution is described in the section "Difference between synchronous
and asynchronous instructions".

Explanation of the call of the instruction


The figure above shows case 2 of the example program "Analyze_Connection".
This part of the program requests the current values for "ConnectionStatus", "ServerState" and
"ServiceLevel" from the connected OPC UA server, which are not evaluated further however.
If the #State tag is 2, then case 2 is executed.
If the "OPC_UA_ConnectionGetStatus" instruction is not yet executed, #Busy is FALSE, so that the
"#Req" tag is set to TRUE. This starts the instruction. In the next cycle, #Req is FALSE.
If the output parameter "Error" is TRUE, an error occurred during execution of the instruction.
This sets the "#State" tag to the value 100. This case is reserved for troubleshooting.
If the output parameter "Done" is TRUE, the instruction was executed successfully. This increases
the value of the "#State" tag by one. This means the next program section - case 3 - is executed
in the next cycle. Case 3 is described in OPC_UA_Disconnect: Close the connection.
See also
Using the S7-1500 CPU as an OPC UA client (S7-1500, S7-1500T)

146 Manual, 11/2024


1.1.1.6.2 Diagnosing the OPC UA server with OPC_UA_ReadList (S7-1500)

Validity
The following description is valid for S7-1500 CPUs as of firmware version V3.0.

Requirements
You have activated the OPC UA server on your S7-1500 CPU.

Note
Diagnosing the OPC UA server with OPC_UA_ReadList
The "OPC_UA_ReadList" instruction belongs to the OPC UA client instructions.
However, if you use it to run diagnostics on the OPC UA server of the local CPU, it
works independently of any client functionality. This means that there is no
handling of connections and the OPC UA client on your CPU does not have to be
activated. If you have activated it, the call of "OPC_UA_ReadList" used this way is
not part of the client program.

Description
You may use the "OPC_UA_ReadList" instruction under the above mentioned conditions to read
tag nodes of the server address space of the OPC UA server of the local CPU (localhost
connection). You can thereby access those nodes that are available when the standard SIMATIC
server interface is deactivated.
Your program has the same access rights as a remote OPC UA client with guest authentication
(anonymous user) and security policy "None". This means, for example, that the
SessionSecurityDiagnosticsArray cannot be read by your user program.

Difference to the previous use of OPC_UA_ReadList


For S7-1500 CPUs with firmware version < V3.0, the "OPC_UA_ReadList" instruction can only be
used to read PLC tags of a remote OPC UA server. To do this, other instructions must be called
beforehand, including those to establish a connection. In addition, further instructions must be
called after the read operation in order to release resources again.
These pre-processing and post-processing steps are not required if you use the instruction
"OPC_UA_ReadList" to diagnose the OPC UA server of the local CPU. In this case,
"OPC_UA_ReadList" works completely independent.
When using "OPC_UA_ReadList" to run diagnostics on the OPC UA server of the local CPU, some
parameters have a different meaning than when reading PLC tags of a remote OPC UA server.
This is especially true for the "ConnectionHdl" parameter. With it you define how you want to use
the instruction.
The changed meaning of the parameters is explained in detail in the parameter table.

Functional description
The "OPC_UA_ReadList" instruction is an asynchronous working instruction. Processing extends
over multiple calls. You start processing with a rising edge at the "Req" parameter.
The parameters "Busy" and "Done" indicate the status of the job.

Manual, 11/2024 147


If an error occurs during execution, this is signaled by the parameters "Error" and "Status".
See also: Difference between synchronous and asynchronous instructions

Parameters
The following table shows the parameters of the "OPC_UA_ReadList" instruction if you want to
use it to run diagnostics on the OPC UA server of the local CPU.

Parameters Declaration Data Description


type

Req Input Bool Control parameter Request


Activates the job on a positive edge.

ConnectionHdl Input DWord Note: This parameter has a different meaning


than when reading PLC tags of a remote OPC
UA server.
Decimal value -42 (16#FFFFFFD6)
This value causes "OPC_UA_ReadList" to read
nodes on the OPC UA server of the local CPU.

NodeHdlCount Input UINT Number of elements in the array pointed to


by the "NodeHdls" parameter.

NodeHdls InOut Variant Note: This parameter has a different meaning


than when reading PLC tags of a remote OPC
UA server.
Pointer to an array with elements of the
OPC_UA_NodeId type, see OPC_UA_NodeId
The array contains the nodes of the local
server interfaces.
All nodes can be read that are available when
the standard SIMATIC server interface is
deactivated.

NodeAddInfos InOut Variant Pointer to an array of the type


OPC_UA_NodeAdditionalInfo or
OPC_UA_NodeAdditionalInfoExt
The array defines which attribute is to be read
in the node (in a tag).
The first element of this array refers to the
first element in the array pointed to by the
"NodeHdls" parameter.
The parameter is optional. If it is not set, the
values of all nodes (tags) are read.
When reading arrays, it is possible to restrict
the elements of the array to be read, see Read

148 Manual, 11/2024


array area with Reading array range information
with OPC_UA_ReadList.

Timeout Input Time Note: This parameter has a different meaning


than when reading PLC tags of a remote OPC UA
server.
This parameter is not evaluated.

Done Output Bool Status parameter with the following values:

0: Job not yet started or still being processed.

1: Job completed without error. This state is

only displayed for one call.

Busy Output Bool Status parameter with the following values:

0: Job not yet started or already completed.

1: Job not yet completed. A new job with this

instance cannot be started.

Error Output Bool Status parameter

0: No error occurred.

1: Error occurred during processing.

The "Status" parameter provides detailed


information on the type of error. This state is only
displayed for one call.

Status Output DWord Return value or error information of the


"OPC_UA_ReadList" instruction, see below.

NodeStatusList InOut Variant Pointer to an array of the type DWORD.


The array contains the error codes for the
individual tags (see below "Error numbers for
NodeStatusList").
For each tag, it is specified whether its value could
be read.
It may happen that the instruction was
successfully executed ("Error" parameter not set),
but no value could be read for a particular NodeId
(tag).

Manual, 11/2024 149


The parameter is optional. If it is missing, the OPC UA
server does not provide a time stamp.

Variable InOut Variant Pointer to a structure or PLC data type (UDT).


The pointer points to the target area (for the read values).

You can find additional information on valid data types under Overview of the valid data types

"Status" parameter
When the "Error" parameter has the value 1, you can use the "Status" parameter to determine
the cause of the error that occurred.
The following table contains the possible error codes.

Error code Name of the error Explanation


(16#...)

8003_0000 OpcUa_BadOutOfMemory The memory allocation during the


preparation of the call was not
successful. This may have several
sporadic causes.

B080_0100 Simatic_BadType_VariantInput1 The value assigned to the NodeHdls


parameter points to an element of
wrong type. NodeHdls must be a
pointer to an array with elements of
the OPC_UA_NodeId type.

B080_0200 Simatic_BadType_VariantInput2 The value assigned to the


NodeAddInfos parameter points to an
element of wrong type. NodeAddInfos
must be a pointer to an array of type
OPC_UA_NodeAdditionalInfo or
OPC_UA_NodeAdditionalInfoExt.

B080_0300 Simatic_BadType_VariantInput3 The value assigned to the


NodeStatusList parameter points to an
element of wrong type.
NodeStatusList must be a pointer to
an array of the DWORD type.

B080_0400 Simatic_BadType_VariantInput4 The value assigned to the TimeStamps


parameter points to an element of
wrong type. TimeStamps must be a
pointer to an array of the LDT type.

B080_0500 Simatic_BadType_VariantInput5 The value assigned to the Tag


parameter points to an element of
wrong type. Tag must be a pointer to
a structure or a PLC data type (UDT).

150 Manual, 11/2024


B080_1100 Simatic_ArrayElements_TooMany NodeHdlCount >
MAX_ELEMENTS_NODELIST (300)

B080_3100 BadNumElements_VariantInput1 The value of NodeHdlCount is greater


than the size of the array pointed to
by NodeHdls.

B080_3200 BadNumElements_VariantInput2 The value of NodeHdlCount is greater


than the size of the array pointed to
by NodeAddInfos.

B080_3300 BadNumElements_VariantInput3 The value of NodeHdlCount is greater


than the size of the array pointed to
by NodeStatusList.

B080_3400 BadNumElements_VariantInput4 The value of NodeHdlCount is greater


than the size of the array pointed to
by TimeStamps.

B080_3500 BadNumElements_VariantInput5 The value of NodeHdlCount is greater


or less than the number of value
elements pointed to by the "Tag"
parameter.

B080_C300 Simatic_InsufficientResources The OPC UA server cannot be


reached, for example, because there
is not enough memory.

B080_C500 Simatic_SimaticNothingToDo NodeHdlCount has the value 0.

B080_C700 Simatic_ServerNotEnabled The OPC UA server is not activated.

B080_C800 Simatic_ServerNotAvailable The OPC UA server is activated but


not yet available.

B080_C900 Simatic_ServerNotInitialized The OPC UA server is activated and


available but not yet initialized.

"NodeStatusList" parameter
Each element in the "NodeStatusList" parameter indicates whether the value for the associated
NodeId in NodeHDls could be successfully read. NodeStatusList is only valid if "Done" has the
value TRUE. Elements whose index is >= NodeHdlCount are ignored and are invalid.

Note
NodeStatusList
It is strongly recommended to always use and evaluate the "NodeStatusList"
parameter.

Manual, 11/2024 151


The following table explains the error codes.

Error code Name of the error Explanation


(16#...)

8003_0000 OpcUa_BadOutOfMemory The memory allocation during the


preparation of the call was not
successful. This may have several
sporadic causes.

801F_0000 OpcUa_BadUserAccessDenied The user program does not have the


required rights to read the requested
node, e.g.
SessionSecurityDiagnosticsArray

8034_0000 OpcUa_BadNodeIdUnknown The OPC_UA_NodeId refers to a node


that does not exist in the server's
address space.

803D_0000 OpcUa_BadNotSupported The attribute cannot be read for this


NodeId. Possible causes:

The OPC_UA_NodeId belongs to the


standard SIMATIC server interface.

The OPC_UA_NodeId is an OPC


UA_node that does not support the

attribute to be read.

The value of the attribute is read at

an object node.

803E_0000 OpcUa_BadNotFound The NamespaceIndex in the


OPC_UA_NodeId could not be resolved.

8074_0000 OpcUa_BadTypeMismatch The data type of the element at the


"Tag" parameter does not match the
data type of the associated OPC UA
node.

Applications
The following table lists some important use cases.
The following designations are used:

ns: NamespaceIndex of the node in the OPC UA server

i: Numeric identifier of the node

152 Manual, 11/2024


s: String identifier of the node

You can determine the data specified in the "Comment" column (e. g.
"ServerDiagnosticsSummary"), for example with this tool: Siemens OPC UA Modeling Editor
(SiOME)

Use case Source Comment

Determine NamespaceArray (ns=0; Namespaces have a unique name. The


NamespaceIndex i=2255) server assigns a namespace index to
each namespace when the namespace is
created at runtime. When reading the
"NamespaceArray" of the server, this
namespace index can be accessed and
evaluated.

Determine CurrentSessionCount Each client creates at least one session.


number of (ns=0; i=2277) This information could help to determine
connected if all partners of the machine are
clients properly connected. All nodes below
(ns=0; i=2275)
"ServerDiagnosticsSummary" (of which
"CurrentSessionCount" is a component)
have a fixed NodeId in ns=0.

Check overall ServerState The OPC UA server has an overall status


status of the (ns=0; i=2259) (e.g. failed, running, etc.) that may be of
server interest to the user program.

Manual, 11/2024 153


Subscription SubscriptionDiagnosticsArray The OPC UA server keeps track of all subscriptions and
diagnostics monitored objects. Several parameters can be of
(ns=0; i=2290)
interest, e.g. LateSubscriptions, expired subscriptions.
An entry is created in the SubscriptionDiagnosticsArray
for each subscription. In other words, the size of this
array is variable. You must either provide a sufficiently
large array in your user program or access a subset of
this array using the NodeAddInfos parameter (see
Reading array range information with
OPC_UA_ReadList). To determine the current number
of subscriptions, read the node
CurrentSubscriptionCount (ns=0; i=2285) in the same
read job. This allows you to determine how many
values in the array are currently valid. If you want to
access a single element of the
SubscriptionDiagnosticsArray in your program, you
need the Subscription ID, because it is part of the
NodeId, e.g. ns=1;
s=Subscription_<SubscriptionId>.MonitoredItemCount.
The Subscription ID is not known at the time of
configuration.

Static nodes ns=3; s=DeviceManual You can read in your program those nodes that are
of available if the standard SIMATIC server interface has
namespace ns=3; s=DeviceRevision been deactivated in TIA Portal.
3 (standard
SIMATIC ns=3;
interface)
s=EngineeringRevision

ns=3;

s=HardwareRevision

ns=3; s=Manufacturer

ns=3; s=Model

ns=3; s=OperatingMode

ns=3; s=OrderNumber

ns=3; s=RevisionCounter

ns=3; s=SerialNumber

ns=3; s=SoftwareRevision

Additional notes on session diagnostics


The SessionDiagnosticsArray (ns=0; i=3707) is of the OPC UA data type
"SessionDiagnosticsDataType". This data type contains two "dynamic" arrays: "LocalIds" and

154 Manual, 11/2024


"Client.Description.DiscoveryUrls". This means that the size of these arrays is not known at the
time of configuration.
Up to and including firmware version V2.9, the size of an array that is part of a structure in your
program must exactly match the size of the OPC UA array that is read. As of firmware version
V3.0, the array size in the PLC program may be larger than the size of the read OPC UA array.
This applies for read accesses on the OPC UA server of the local CPU as well as for read accesses
of an OPC UA client on a remote OPC UA server. It is recommended that you completely reset the
values in your program before the read operation, because the firmware of the PLC does not do
this. If the currently read array is smaller than the previously read one, there is a risk that you are
accessing old or invalid values in your program.
The following applies in regard to compatibility: Accesses that have worked so far will continue
to work. Accesses that were previously incorrect may now return values.
If you want to access a single element of the SessionDiagnosticsArray (ns=0;i=3707) in your
program, you have to determine the session ID first. The session ID is part of the NodeId and not
yet known at the time of configuration. For example, if you want to determine the
"ClientLastContactTime" for a certain session, the NodeId looks like this: ns=1;
s=Session_<SessionId>. SessionDiagnostic. ClientLastContactTime. One way to determine the
session ID is to read the SessionDiagnosticsArray (ns=0; i=3707) and use, for example, the
session name to identify the session you are looking for. Both the session name and the session
ID are part of the OPC UA "SessionDiagnosticsDataType" and are therefore contained in the
SessionDiagnosticsArray (ns=0; i=3707) for each session.

More information
You are supported by an application example on the topic "Diagnosing the OPC UA server with
OPC_UA_ReadList": OPC UA server SIMATIC S7-1500 self-diagnostics
See also
Diagnostics of the OPC UA server (S7-1500, S7-1500T)
OPC_UA_SessionConnectInfo (S7-1500)
Running diagnostics for OPC UA servers in the program (S7-1200, S7-1500, S7-1500T)

1.1.1.7 Methods (S7-1500)

1.1.1.7.1 OPC_UA_MethodGetHandleList: Get handles for method calls (S7-1500)

Validity
The following description of the "OPC_UA_MethodGetHandleList" instruction applies to S7-1500
CPUs with firmware version V2.6 and higher.

Description
A programming example shows how to use the instruction in SCL.
This section assumes that you are creating and configuring a client interface for OPC UA
communication; see "Creating client interfaces". The efficient procedure ensures that most
parameters for the client instruction are supplied automatically.
You use the instruction "OPC_UA_MethodGetHandleList" in your user program to receive
numerical references (handles) from the server for methods that the server provides for OPC UA
clients. OPC_UA_MethodGetHandleList is used to prepare method calls, see ① in the figure
below.
The instruction returns the handles for the server methods.

Manual, 11/2024 155


① Instructions for preparation of method calls

② Method calls

③ Instructions for "clean-up" after completed method calls

Parameters for "OPC_UA_MethodGetHandleList"


The parameters of the instruction "OPC_UA_MethodGetHandleList"

Parameters Declaration Data type Meaning


in area

REQ Input BOOL A rising edge 0 → 1 at the


parameter triggers execution
of the instruction.

ConnectionHdl Input DWORD Unique identifier for a


connection established.
You get the handle from the
instruction OPC_UA_Connect:
Create connection.

NodeIDCount Input UINT Number of elements in the


ObjectNodeIDs or
MethodeNodeIDs parameter

ObjectNodeIDs InOut VARIANT Pointer to an array with


elements of the type
OPC_UA_NodeId.
The array contains the node
IDs (NodeIDs) of the objects
(folders) in which the methods
are located.

156 Manual, 11/2024


MethodNodeIDs InOut VARIANT Pointer to an array with elements of the
type OPC_UA_NodeId.
The array contains the node IDs
(NodeIDs) of the methods for which
handles are requested from the server.

Timeout Input TIME Maximum time for execution of the


instruction in milliseconds. See also
explanation for this parameter in
OPC_UA_Connect: Create connection

NamespaceIndexCount Input UINT Number of array elements in the


parameter NamespaceIndexes.

NamespaceIndexes InOut VARIANT Pointer to an array of the type UINT.


This parameter is not required if there
are no elements in the
NamespaceIndexCount parameter
(NamespaceIndexCount = 0).
The array is used to assign new indexes
to the namespace indexes in the
NodeIDs parameter.
Example:
If there is a value of 10 in
NamespaceIndexes[4], all NodeIds in
the "NodeIDs" parameter that previously
had the namespace index 4 are
assigned the namespace index 10.

Done Output BOOL Status of execution:

0: Execution of the instruction

aborted, not yet complete or not yet


started

1: Execution of instruction
completed without errors

Busy Output BOOL Execution status parameter:

0: Instruction not being executed

1: Instruction currently being

executed

Error Output BOOL Error display

0: No error

Manual, 11/2024 157


1: An error has occurred. See "Status"
parameter.

Status Output DWORD Cause of the error, see "Error numbers for Status"
below

StatusList InOut VARIANT Pointer to an array of the type DWORD.


The array contains the error codes for the
individual methods; see "Error numbers for
NodeStatusList" below.
For each method, the system specifies whether or
not a corresponding handle could be found.

MethodHdls InOut VARIANT Pointer to an array of the type DWORD.


The array contains the handles for the individual
methods (NodeIDs) returned by the OPC UA server.

Determining the "ObjectNodeIDs" and "MethodNodeIDs" parameters


ObjectNodeIDs
You can determine OPC_UA_NodeId, which must be entered at the "ObjectNodeIDs" parameter,
for example with UaExpert:

MethodNodeIDs
You can find the OPC_UA_NodeId at the "MethodNodeIDs" parameter here:

158 Manual, 11/2024


Error numbers for Status
The following table shows a summary of error codes for this instruction:

Error code Name of the error Explanation


(hex.
values)

0000_0000 OpcUa_Good Instruction finished successfully.

0070_0000 - First call without rising edge at REQ,


which means job execution is not
started

0070_0100 - First call with start of job execution

0070_0200 - Subsequent call

8003_0000 OpcUa_BadOutOfMemory No memory available for the OPC UA


client.
As the OPC UA client and OPC UA server
share a memory area, you should reduce
the memory requirement of the server.
You have the following options:

Release fewer PLC tags for OPC UA.

Reduce the number of OPC UA

clients that are currently connected


to the server.

Manual, 11/2024 159


Set up fewer subscriptions.

8009_0000 OpcUa_BadUnknownResponse Server does not respond with the


expected number of results

800A_0000 OpcUa_BadTimeout A network timeout occurred.


Possible causes:

Connection to the OPC UA server

is too slow (insufficient capacity)

The network load is too high.

The OPC UA server is not available.

Possible remedy:

Check the URL of the OPC UA

server

Increase the timeout setting

(higher value for the Timeout


parameter of the function block

OPC_UA_Connect).

800D_0000 OpcUa_BadServerNotConnected The server is not connected or the


connection handle is incorrect or
invalid.

800F_0000 OpcUa_BadNothingToDo Nothing to do: The OPC UA server


received an empty list with no
instructions from the OPC UA client.

8010_0000 OpcUa_BadTooManyOperations Number of


"OPC_UA_MethodGetHandleList"
instructions that can be called at the
same time per connection has been
exceeded (> 1), see: Number of client
instructions that can be used
simultaneously

8074_0000 OpcUa_BadTypeMismatch You are using a data type that does


not correspond to the data type in the
server.

B080_0100 Simatic_BadType_VariantInput1 Incorrect data type for parameter


"ObjectNodeIDs".

160 Manual, 11/2024


B080_0200 Simatic_BadType_VariantInput2 Incorrect data type for
parameter "MethodNodeIDs".

B080_0300 Simatic_BadType_VariantInput3 Incorrect data type for


parameter
"NamenspaceIndexes".

B080_0400 Simatic_BadType_VariantInput4 Incorrect data type for


parameter "StatusList".

B080_0500 Simatic_BadType_VariantInput5 Incorrect data type for


parameter "MethodHdls".

B080_1100 Simatic_ArrayElements_TooMany Maximum number allowed for


method list
(Max_ELEMENTS_METHODLIST)
exceeded.

B080_3100 Simatic_BadNumElements_VariantInput1 Incorrect number of array


B080_3200 Simatic_BadNumElements_VariantInput2
elements at the
B080_3300 Simatic_BadNumElements_VariantInput3
1st VARIANT parameter
B080_3400 Simatic_BadNumElements_VariantInput4
(VariantInput1):
B080_3500 Simatic_BadNumElements_VariantInput5
General: General: NodeIDCount > Number of
B080_3N00(N=Nth Simatic_BadNumElements_VariantInputN array elements from
VARIANT of the
(N=nth version of the instruction)
instruction) ObjectNodeIDs

Incorrect number of array


elements at the

2nd VARIANT parameter

(VariantInput2):

NodeIDCount > Number of

array elements from


MethodNodeIDs

Incorrect number of array


elements at the

3rd VARIANT parameter

(VariantInput3):

NamespaceIndexCount >

Number of array elements

Manual, 11/2024 161


from NamespaceIndexes

Incorrect number of array elements at the

4th VARIANT parameter (VariantInput4):

NodeIDCount > Number of array

elements from StatusList

Incorrect number of array elements at the

5th VARIANT parameter (VariantInput5):

NodeIDCount > Number of array

elements from MethodHdls

General: Wrong number of elements for the


Nth VARIANT parameter.

B080_C400 Simatic_ClientNotEnabled The OPC UA client is disabled.

B080_C500 Simatic_NothingToDo Nothing to do: The instruction is using a list


that contains no elements.

C080_C300 Simatic_OutOfResources The maximum number of client instructions


that can be used at the same time has been
exceeded.
Possible remedy:

Reduce the number of client instructions

of the type running parallel, see: Number

of client instructions that can be used

simultaneously

For more error codes, see Error codes.

Error numbers for StatusList


The StatusList parameter contains an error code for each individual node ID (method).
The following table explains the error codes:

Error code Name of the error Explanation


(hex.
values)

0000_0000 OpcUa_Good No error

162 Manual, 11/2024


8033_0000 OpcUa_BadNodeIdInvalid The syntax of the node ID (NodeId) is
incorrect.

8034_0000 OpcUa_BadNodeIdUnknown The NodeId refers to a node (method) that


does not exist on the OPC UA server.

8074_0000 OpcUa_BadTypeMismatch InputArguments / OutputArguments have


incorrect type

For more error codes, see Error codes.

Requirements
The following description assumes that:

You have created a client interface, see "Creating client interfaces".

You have created and configured a connection to an OPC UA server, see "Creating and
configuring connections".

In addition, the following requirements must also be met for the instruction
"OPC_UA_MethodGetHandleList" (cf diagram above):

A handle for connection to an OPC UA server is available.

You get the connection handle from the instruction OPC_UA_Connect.

Indexes of the namespaces in which the methods you want to call are located.

You get the indices from the instruction OPC_UA_NamespaceGetIndexList: Read namespace
indexes.

Function of the instruction


To speed up method calls, OPC UA servers use numeric references (handles) for methods.
You get these handles from the OPC UA server with the instruction
"OPC_UA_MethodGetHandleList".
You need these handles for the OPC UA instruction for calling methods, "OPC_UA_MethodCall".

How to use a configured connection


1. In the "Project tree" area, select the CPU you want to use as a client.

2. Select the function block that is to execute the client instruction in the "Program blocks"

folder.

In the example, the function block is called "Call_OpenDoor_On_Productionline".

Selected language: SCL.

Manual, 11/2024 163


3. Use drag-and-drop to move the instruction "OPC_UA_MethodGetHandleList" from the folder
"Instructions > Communication > OPC UA > OPC UA Client" to the editor.

4. Select the call as multi-instance.

STEP 7 creates an instance of this instruction and calls it

"OPC_UA_MethodGetHandleList_Instance".

5. Click on the icon for "Start configuration" at the "OPC_UA_MethodGetHandleList_Instance"

instruction.

STEP 7 opens the "Configuration" tab in the Inspector window.

6. Under "Select client interface for OPC UA interface" you select the client interface that you

want to use for the instruction.

In the example, the client interface is called "Productionline", see "Creating client interfaces".

7. Click "Data access" and select a method list.

In the example, the method list is named "MethodListOpenDoor".

STEP 7 now automatically supplies most parameters of the instruction with the correct tags.

8. Click on "Block parameters" and assign tags manually to the remaining parameters.

STEP 7 adds the selected tag to the function call.

Calling the instruction (initial call)


The following excerpt from the program "Call_OpenDoor_On_Productionine" shows how to use
the instruction "OPC_UA_MethodGetHandleList".
You can find the complete example program in the section Example program for calling a
method of an OPC UA server
The example program is divided into multiple sections (Cases) by a CASE instruction.
Case 3 is shown here:

SCL

3: // case 3, get an handle for server method OpenDoor


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_MethodGetHandleList_Instance(REQ := #Req,

164 Manual, 11/2024


ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeIDCount :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodCo
ObjectNodeIDs :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".ObjectNo
MethodNodeIDs :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodNo
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NamespaceIndexCount :=
"Productionline_Configuration".Namespaces.NamespaceCount,
NamespaceIndexes :=
"Productionline_Configuration".Namespaces.ServerNamespaceIndexes,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status,
StatusList :=
"Productionline_Data"."MethodListOpenDoor".MethodStatusList,
MethodHdls :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodHd

Asynchronous execution
The instruction "OPC_UA_MethodGetHandleList" runs asynchronously to the user program and
requires multiple program cycles.
You can check the job status with the "Busy", "Done", "Error" and "Status" parameters.
Asynchronous program execution is described in the section "Difference between synchronous
and asynchronous instructions".

Explanation of the call of the instruction (initial call)


The figure above shows case 3. This part of the program registers the "OpenDoor" method on
the OPC UA server. The "OPC_UA_MethodGetHandleList" method is called for this.
If the instruction is not yet executed, #Busy is FALSE, so that the "#Req" tag is set to the value
TRUE. This starts the instruction. In the next cycle, #Req is FALSE.

Calling the instruction (troubleshooting)


The figure below shows evaluation of the "Done" and "Error" parameters.

SCL

IF #Done = TRUE THEN

Manual, 11/2024 165


IF
"Productionline_Data"."MethodListOpenDoor".MethodStatusList[0] = 0 THEN
//one method
#State := #State + 1;
ELSE
#State := 100;
//In case 100, set REQ of instruction "OPC_UA_Disconne
to FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#Output_Error_Message := WString#'Error at
MethodGetHandleList';
END_IF;
END_IF;
IF #Error = TRUE THEN
#State := 100;
//In case 100, to set REG of instruction "OPC_UA_Disconnect"
FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#OPC_UA_MethodGetHandleList_Instance(REQ := FALSE,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeIDCount :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodCo
ObjectNodeIDs :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".ObjectNo
MethodNodeIDs :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodNo
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NamespaceIndexCount :=
"Productionline_Configuration".Namespaces.NamespaceCount,
NamespaceIndexes :=
"Productionline_Configuration".Namespaces.ServerNamespaceIndexes,
StatusList :=
"Productionline_Data"."MethodListOpenDoor".MethodStatusList,
MethodHdls :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodHd
END_IF;

166 Manual, 11/2024


Explanation of the call of the instruction (troubleshooting)
If an error occurs, the value TRUE is set at the "Error" output parameter. This sets "#State" to the
value 100. This case is reserved for troubleshooting.
If the output parameter "Done" is TRUE, the instruction was executed successfully.
It is possible that the instruction was successfully executed ("Error" parameter not set, "Done"
parameter set) but no handle could be returned for a method.
Therefore, there is a check in the example to determine whether the handle for the "OpenDoor"
method has been returned:

If the condition is met, the value of the "#State" tag is increased by one. This means the next
program section - case 4 (Call method) - is executed in the next cycle. Case 4 is described in

OPC_UA_MethodCall: Call method.

If the condition is not met, this is assessed as an error and #State has a value of 100. The

error case is run through in the next cycle.

Note
If you register a multiple methods with OPC_UA_MethodGetHandleList in your
application, it can be useful always to increase #State by one when #Done = TRUE
and only check whether a valid handle was returned for a given method in
question before the individual methods are called with "OPC_UA_MethodCall" (in
case 4).

1.1.1.7.2 OPC_UA_MethodCall: Call method (S7-1500)

Validity
The following description of the "OPC_UA_MethodCall" instruction applies to S7-1500 CPUs with
firmware version V2.6 and higher.

Description
You use the instruction "OPC_UA_MethodCall" in your user program to call a method on the
server.
The figure below shows the structure of a user program. The "OPC_UA_MethodCall" instruction
is located in section ②:

① Instructions for preparation of method calls

Manual, 11/2024 167


② Method calls

③ Instructions for "clean-up" after completed method calls

Parameters for "OPC_UA_MethodCall"


The parameters of the instruction "OPC_UA_MethodCall"

Parameters Declaration Data type Meaning


in area

REQ Input BOOL A rising edge 0 → 1 at the


parameter triggers execution
of the instruction.

ConnectionHdl Input DWORD Unique identifier for a


connection established.
You get the handle from the
instruction OPC_UA_Connect:
Create connection.

Timeout Input TIME Maximum time for execution


of the instruction in
milliseconds.
See also the explanation for
this parameter in
OPC_UA_Connect: Create
connection.

MethodHdl Input DWORD Handle for the method to be


called.

InputArguments InOut VARIANT Pointer to a tag with the PLC


data type (UDT) or STRUCT,
the name, number, order and
data type of which correspond
to the expected input
parameters.

OutputArguments InOut VARIANT Pointer to a tag with the PLC


data type (UDT) or STRUCT,
the name, number, order and
data type of which correspond
to the expected output
parameters.

168 Manual, 11/2024


complete or not yet started

1: Execution of instruction completed without

errors

Busy Output BOOL Execution status parameter:

0: Instruction not being executed

1: Instruction currently being executed

Error Output BOOL Error display

0: No error

1: An error has occurred. See "Status"

parameter.

Status Output DWORD Cause of the error, see "Error numbers for Status"
below

MethodResult InOut VARIANT Pointer to a tag of the type DWORD that contains
the error code (result) of the server method
called.
This error code is provided by the user program of
the OPC UA server. In the case of an S7-1500 CPU
as OPC UA server, it is the "UAMethod_Result"
parameter of the server instruction
"OPC_UA_ServerMethodPost" that you can read
out with the client instruction
"OPC_UA_MethodCall".
If the instruction "OPC_UA_MethodCall" was not
executed (Error = true, Status <> 0), no value is
set for MethodResult.

Error numbers for Status


The Status parameter provides information about errors that occur during execution of the
instruction.
The following table explains the error codes:

Error code Name of the error Explanation


(hex. values)

0000_0000 OpcUa_Good Instruction finished successfully.

Manual, 11/2024 169


0070_0000 - First call without rising edge at REQ,
which means job execution is not
started

0070_0100 - First call with start of job execution

0070_0200 - Subsequent call

8003_0000 OpcUa_BadOutOfMemory No memory available for the OPC UA


client.
As the OPC UA client and OPC UA server
share a memory area, you should
reduce the memory requirement of the
server.
You have the following options:

Release fewer PLC tags for OPC UA.

Reduce the number of OPC UA


clients that are currently connected

to the server.

Set up fewer subscriptions.

8006_0000 OpcUa_BadEncodingError Error decoding the output argument

8009_0000 OpcUa_BadUnknownResponse Server does not respond with the


expected number of results

800A_0000 OpcUa_BadTimeout A network timeout occurred.


Possible causes:

Connection to the OPC UA server is


too slow (insufficient capacity)

The network load is too high.

The OPC UA server is not available.

Possible remedy:

Check the URL of the OPC UA server

Increase the timeout setting (higher

value for the Timeout parameter of


the function block

OPC_UA_Connect).

170 Manual, 11/2024


800D_0000 OpcUa_BadServerNotConnected The server is not connected or the
connection handle is incorrect or
invalid.

800F_0000 OpcUa_BadNothingToDo Nothing to do: The OPC UA server


received an empty list with no
instructions from the OPC UA client.

8010_0000 OpcUa_BadTooManyOperations Number of "OPC_UA_MethodCall"


instructions that can be called at the
same time per connection has been
exceeded (> 5), see:
Number of client instructions that can
be used simultaneously

8034_0000 BadNodeIdUnknown The node id refers to a node that does


not exist in the server address space.
The NamespaceIndex of the specified
NodeId might not exist. If the error
code is displayed when the instruction
"OPC_UA_MethodCall" is called:
Another possible cause is the use of
invalid ObjectIDs in the preceding call
of OPC_UA_MethodGetHandleList.
The instruction
"OPC_UA_MethodGetHandleList" does
not evaluate the ObjectIDs.

8074_0000 OpcUa_BadTypeMismatch Argument variant has incorrect type.

8075_0000 OpcUa_BadMethodInvalid No registered method for the specified


MethodHdl

8076_0000 BadArgumentsMissing The client has not specified all


specified input arguments.

80AB_0000 OpcUa_BadInvalidArgument Input arguments have incorrect type.

B080_0100 Simatic_BadType_VariantInput1 Incorrect data type for parameter


"MethodResult" to which the 1st
variant parameter of the instruction
points.

B080_0200 Simatic_BadType_VariantInput2 Incorrect data type for parameter


"InputArguments" to which the 2nd
variant parameter of the instruction
points.

B080_0300 Simatic_BadType_VariantInput3 Incorrect data type for parameter


"OutputArguments" to which the 3rd

Manual, 11/2024 171


variant parameter of the instruction
points.

B080_1100 Simatic_ArrayElements_TooMany General error code. Occurs when an


array has too many elements.

B080_C400 Simatic_ClientNotEnabled The OPC UA client is disabled.

B080_C500 Simatic_NothingToDo Nothing to do: The instruction is


using a list that contains no
elements.

C080_C300 Simatic_OutOfResources The maximum number of client


instructions that can be used at the
same time has been exceeded.
Possible remedy:

Reduce the number of client

instructions of the type running

parallel, see:
Number of client instructions that

can be used simultaneously

For more error codes, see Error codes.

Requirements
The following description assumes that:

You have created a client interface, see "Creating client interfaces".

You have created and configured a connection to an OPC UA server, see "Creating and

configuring connections".

In addition, the following requirements must also be met for the instruction
"OPC_UA_MethodCall" (cf diagram above):

A handle for connection to an OPC UA server is available.

You get the connection handle from the instruction, see OPC_UA_Connect: Create
connection.

Indexes of the namespaces that contain the methods that you want to call with the client.

You get the indexes from the instruction "OPC_UA_NamespaceGetIndexList".

A handle for the method that you want to call in your user program.

172 Manual, 11/2024


You get the handle from the instruction, see OPC_UA_MethodGetHandleList: Get handles for
method calls.

Function of the instruction


You use the instruction "OPC_UA_MethodCall" to call a method that has been released in an OPC
UA server.

How to use a configured connection


1. In the "Project tree" area, select the CPU you want to use as a client.

2. Select the function block that is to execute the client instruction in the "Program blocks"

folder.

In the example, the function block is called "Call_OpenDoor_On_Productionline".

Selected language: SCL.

3. Use drag-and-drop to move the instruction "OPC_UA_MethodCall" from the folder

"Instructions > Communication > OPC UA > OPC UA Client" to the editor.

4. Select the call as multi-instance.

STEP 7 creates an instance of this instruction and calls it "OPC_UA_MethodCall_Instance".

5. Click on the icon for "Start configuration" at the "OPC_UA_MethodCall_Instance" instruction.

STEP 7 opens the "Configuration" tab in the Inspector window.

6. Under "Select client interface for OPC UA interface" you select the client interface that you

want to use for the instruction.

In the example, the client interface is called "Productionline".

7. Click "Data access" and select a method list.

In the example, the method list is called "MethodListOpenDoor".

STEP 7 automatically supplies most parameters of the instruction with tags, but not the

parameters Busy, Done, Error.

8. Create the local tags for the parameters yet to be supplied.

9. Click on "Block parameters" and assign the local tags to the remaining parameters.

STEP 7 adds the selected tag to the function call.

Calling the instruction (initial call)

Manual, 11/2024 173


The following excerpt from the program "Call_OpenDoor_On_Productionine" shows how to use
the instruction "OPC_UA_MethodCall".
You can find the complete example program in the section Example program for calling a
method of an OPC UA server.
The example program is divided into multiple sections (Cases) by a CASE instruction.
Case 4 is shown here:

SCL

4: // case 4, call method OpenDoor


IF #Init_Method_InputParameter = TRUE THEN
#Init_Method_InputParameter := FALSE;
//for our server method at Productionline, we set input parameter
"Productionline_Data".MethodListOpenDoor.Method.Inputs.Number :=
END_IF;
IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_MethodCall_Instance(REQ := #Req,
ConnectionHdl:="Productionline_Configuration".Connection.Conn
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
MethodHdl :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodHd
Status =>
"Productionline_Data"."MethodListOpenDoor".MethodStatusList[0],
InputArguments :=
"Productionline_Data"."MethodListOpenDoor"."Method".Inputs,
OutputArguments :=
"Productionline_Data"."MethodListOpenDoor"."Method".Outputs,
MethodResult :=
"Productionline_Data"."MethodListOpenDoor".MethodResultList[0],
Done => #Done,
Busy => #Busy,
Error => #Error);
//"Productionline_Data"."MethodListOpenDoor".MethodResultList[0]] con
//the status/error codes of the server method
//which was run on the connected CPU as user program

174 Manual, 11/2024


//These codes are defined as follows: //
// Good: 0x0000_0000 TO 0x3FFF_ FFFF
// Uncertain: 0x4000_0000 TO 0x7FFF_FFFF
// Bad: 0x8000_0000 TO 0xFFFF_FFFF

Asynchronous execution
The instruction "OPC_UA_MethodCall" runs asynchronously to the user program and requires
multiple program cycles.
You can check the job status with the "Busy", "Done", "Error" and "Status" parameters.
Asynchronous program execution is described in the section "Difference between synchronous
and asynchronous instructions".

Explanation of the call of the instruction (initial call)


The figure above shows case 4. This part of the program calls the server method "OpenDoor" on
the OPC UA server.
The "OPC_UA_MethodCall" instruction receives the handle for the server method and the input
parameters.
In the example, only the "Number" input parameter is used. The value is set to 1, so that the
server method can be fully executed.

Calling the instruction (troubleshooting)


The figure below shows evaluation of the "Done" and "Error" parameters.

SCL

IF #Done = TRUE THEN


IF
"Productionline_Data".MethodListOpenDoor.MethodResultList[0]
< 16#8000_0000 THEN
#State := #State + 1;
ELSE
//server method did not run successfully
#State := 100;
//In case 100, to set REQ of instruction
"OPC_UA_Disconnect" to FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#Output_Error_Message := WString#' Error at server
method';
END_IF;
END_IF;

Manual, 11/2024 175


//In case 100, to set REQ of instruction "OPC_UA_Disconnect" to FALS
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := "Productionline_Data".MethodListOpenDoor.MethodStatus
#OPC_UA_MethodCall_Instance(REQ := #Req,
ConnectionHdl:="Productionline_Configuration".Connection.Conne
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
MethodHdl :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodHd
Status =>
"Productionline_Data"."MethodListOpenDoor".MethodStatusList[0],
InputArguments :=
"Productionline_Data"."MethodListOpenDoor"."Method".Inputs,
OutputArguments :=
"Productionline_Data"."MethodListOpenDoor"."Method".Outputs,
MethodResult :=
"Productionline_Data"."MethodListOpenDoor".MethodResultList[0],
Done => #Done,
Busy => #Busy,
Error => #Error);
END_IF;

Explanation of the call of the instruction (troubleshooting)


If the output parameter "Done" is TRUE, the "OPC_UA_MethodCall" instruction was executed
successfully.
Also check whether the method called on the OPC UA server, "Productionline", was executed
successfully. This is the case if the parameter "MethodResult" contains a value that is less than
16#8000_0000.
If executed successfully, the value of the "#State" tag is increased by one. This means the next
program section - case 5 - is executed in the next cycle.
Case 5 is described in OPC_UA_MethodReleaseHandleList: Release handles for method calls.
If an error occurs, the "OPC_UA_MethodCall" instruction at the "Error" output parameter is set to
the value TRUE. This sets the value of the "#State" tag to 100. This case is reserved for
troubleshooting.
See also
OPC_UA_NamespaceGetIndexList: Read namespace indexes (S7-1500)

1.1.1.7.3 OPC_UA_MethodReleaseHandleList: Release handles for method calls (S7-1500)

Validity

176 Manual, 11/2024


The following description of the "OPC_UA_MethodReleaseHandleList" instruction applies to S7-
1500 CPUs with firmware version V2.6 and higher.

Description
A programming example shows how to use the instruction manually in SCL programming
language.
This section assumes that you are creating and configuring a client interface for OPC UA
communication; see "Creating client interfaces". The efficient procedure ensures that most
parameters for the client instruction are supplied automatically.
You use the instruction "OPC_UA_MethodReleaseHandleList" in your user program to release
numerical references (handles) for methods.
OPC_UA_MethodReleaseHandleList is used to release method handles, see ③ in the figure
below.

① Instructions for preparation of method calls

② Method calls

③ Instructions for "clean-up" after completed method calls

Parameters for "OPC_UA_MethodReleaseHandleList"


The parameters of the instruction "OPC_UA_MethodReleaseHandleList"

Parameters Declaration Data type Meaning


in area

REQ Input BOOL A rising edge 0 → 1 at the


parameter triggers execution
of the instruction.

ConnectionHdl Input DWORD Unique identifier for a


connection established.
You get the handle from the
instruction OPC_UA_Connect:
Create connection.

Timeout Input TIME Maximum time for execution


of the instruction in
milliseconds.

Manual, 11/2024 177


See also the explanation for this parameter in
OPC_UA_Connect: Create connection.

MethodHdlCount Input UINT Number of elements in the MethodHdls


parameter

MethodHdls InOut VARIANT Pointer to an array of the type DWORD.


The array contains the handles for the
individual methods (NodeIds) that are to be
released.

StatusList InOut VARIANT Pointer to an array of the type DWORD.


The array contains the error codes for the
individual methods; see "Error numbers for
NodeStatusList" below.
For each method, it is specified whether a
handle was successfully released.

Done Output BOOL Status of execution:

0: Execution of the instruction aborted, not

yet complete or not yet started

1: Execution of instruction completed

without errors

Busy Output BOOL Execution status parameter:

0: Instruction not being executed

1: Instruction currently being executed

Error Output BOOL Error display

0: No error

1: An error has occurred. See "Status"

parameter.

Status Output DWORD Cause of the error, see "Error numbers for
Status" below

Error numbers for Status


The following table shows a summary of error codes for this instruction:

Error code
(hex.

178 Manual, 11/2024


values)
Name of the error Explanation

0000_0000 OpcUa_Good Instruction finished successfully.

0070_0000 - First call without rising edge at REQ, which


means job execution is not started

0070_0100 - First call with start of job execution

0070_0200 - Subsequent call

8003_0000 OpcUa_BadOutOfMemory No memory available for the OPC UA client.


As the OPC UA client and OPC UA server
share a memory area, you should reduce the
memory requirement of the server.
You have the following options:

Release fewer PLC tags for OPC UA.

Reduce the number of OPC UA clients


that are currently connected to the

server.

Set up fewer subscriptions.

800A_0000 OpcUa_BadTimeout A network timeout occurred.


Possible causes:

Connection to the OPC UA server is too

slow (insufficient capacity)

The network load is too high.

The OPC UA server is not available.

Possible remedy:

Check the URL of the OPC UA server

Increase the timeout setting (higher

value for the Timeout parameter of the

function block OPC_UA_Connect).

Manual, 11/2024 179


800D_0000 OpcUa_BadServerNotConnected The server is not connected or the
connection handle is incorrect or
invalid.

800F_0000 OpcUa_BadNothingToDo Nothing to do: The OPC UA server


received an empty list with no
instructions from the OPC UA client.

8010_0000 OpcUa_BadTooManyOperations Number of


"OPC_UA_MethodReleaseHandleList"
instructions that can be called at the
same time per connection has been
exceeded (> 1), see: Number of
client instructions that can be used
simultaneously

B080_0100 Simatic_BadType_VariantInput1 Incorrect data type for parameter


"MethodHdls".

B080_0200 Simatic_BadType_VariantInput2 Incorrect data type for parameter


"StatusList".

B080_1100 Simatic_ArrayElements_TooMany MethodHdlCount >


MAX_ELEMENTS_METHOD

B080_3100 BadNumElements_VariantInput1 MethodHdlCount > Number of array


elements of the "MethodHdls"
parameter.

B080_3200 BadNumElements_VariantInput2 MethodHdlCount > Number of array


elements of the "StatusList"
parameter.

B080_C400 Simatic_ClientNotEnabled The OPC UA client is disabled.

B080_C500 Simatic_NothingToDo Nothing to do: The instruction is


using a list that contains no
elements.

C080_C300 Simatic_OutOfResources The maximum number of client


instructions that can be used at the
same time has been exceeded.
Possible remedy:

Reduce the number of client


instructions of the type running

parallel, see: Number of client

180 Manual, 11/2024


instructions that can be used simultaneously

For more error codes, see Error codes.

Error numbers for "StatusList"


The "StatusList" parameter contains an error code for each individual handle.
The following table explains the error codes:

Error code Name of the error Explanation


(hex.
values)

0000_0000 OpcUa_Good No error

8034_0000 OpcUa_BadNodeIdUnknown The method handle transferred is not


known.

For more error codes, see Error codes.

Requirements
The following description assumes that:

You have created a client interface, see "Creating client interfaces".

You have created and configured a connection to an OPC UA server, see "Creating and

configuring connections".

In addition, the following requirements must also be met for the instruction
"OPC_UA_MethodReleaseHandleList" (cf diagram above):

A handle for connection to an OPC UA server is available.

You get the connection handle from the instruction OPC_UA_Connect: Create connection.

A list of method handles that you no longer want to call in your user program.

You get this handle list from the instruction OPC_UA_MethodGetHandleList: Get handles for

method calls.

Optional (not needed here): Indexes of the namespaces that contain the methods.

You get the indexes from the instruction OPC_UA_NamespaceGetIndexList: Read namespace

indexes.

Function of the instruction

Manual, 11/2024 181


You call the instruction "OPC_UA_MethodReleaseHandleList" to release handles for methods that
you no longer require in your program.

How to use a configured connection


1. In the "Project tree" area, select the CPU you want to use as a client.

2. Select the function block that is to execute the client instruction in the "Program blocks"
folder.

In the example, the function block is called "Call_OpenDoor_On_Productionline".

Selected language: SCL.

3. Use drag-and-drop to move the instruction "OPC_UA_MethodReleaseHandleList" from the

folder "Instructions > Communication > OPC UA > OPC UA Client" to the editor.

4. Select the call as multi-instance.

STEP 7 creates an instance of this instruction and calls it


"OPC_UA_MethodReleaseHandleList_Instance".

5. Click "OPC_UA_MethodReleaseHandleList_Instance".

STEP 7 opens the "Configuration".

6. Under "Select client interface for OPC UA interface" you select the client interface that you

want to use for the instruction.

In the example, the client interface is called "Productionline", which was created, see

"Creating client interfaces".

7. Click "Data access" and select a method list.

In the example, the method list is named "MethodListOpenDoor".

STEP 7 automatically supplies most parameters of the instruction with tags, but not the

parameters Busy, Done, Error.

8. Create the local tags for the parameters yet to be supplied.

9. Click on "Block parameters" and assign tags manually to the remaining parameters.

STEP 7 adds the selected tag to the function call.

Calling the instruction (initial call)


The following excerpt from the program "Call_OpenDoor_On_Productionine" shows how to use
the instruction "OPC_UA_MethodReleaseHandleList".

182 Manual, 11/2024


You can find the complete example program in the section Example program for calling a
method of an OPC UA server
The example program is divided into multiple sections (Cases) by a CASE instruction.
Case 5 is shown here:

SCL

5: // case 5, release method handle


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_MethodReleaseHandleList_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
MethodHdlCount :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodCo
MethodHdls :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodHd
StatusList :=
"Productionline_Data"."MethodListOpenDoor".MethodStatusList,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);

Asynchronous execution
The instruction "OPC_UA_MethodReleaseHandleList" runs asynchronously to the user program
and requires multiple program cycles.
You can check the job status with the "Busy", "Done", "Error" and "Status" parameters.
Asynchronous program execution is described in the section "Difference between synchronous
and asynchronous instructions".

Explanation of the call of the instruction (initial call)


The figure above shows case 5. This part of the program releases the handle for a server method
again.
In the example, the handle for the "OpenDoor" server method is passed to the "MethodHdls"
parameter.
If this handle cannot be released, the "StatusList" parameter contains an error code.

Manual, 11/2024 183


Calling the instruction (troubleshooting)
The figure below shows evaluation of the "Done" and "Error" parameters.

SCL

IF #Done = TRUE THEN


#Mem_Status := #Status;
IF "Productionline_Data"."MethodListOpenDoor".MethodStatusList[0] =
THEN
#State := #State + 1;
ELSE
#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconnect" to FALS
#Set_REQ_To_FALSE := TRUE;
Mem_Status := #Status;
#Output_Error_Message := WString#'Error at MethodGetHandleList';
END_IF;
END_IF;
IF #Error = TRUE THEN
#State := 100;
//In case 100, to set REG of instruction "OPC_UA_Disconnect" to FALS
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#OPC_UA_MethodReleaseHandleList_Instance(REQ := FALSE,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
MethodHdlCount :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodCo
MethodHdls :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodHd
StatusList :=
"Productionline_Data"."MethodListOpenDoor".MethodStatusList);
END_IF;

Explanation of the call of the instruction (troubleshooting)


If an error occurs, the "OPC_UA_MethodReleaseHandleList" instruction at the "Error" output
parameter is set to the value TRUE. This sets the value of the "#State" tag to 100. This case is

184 Manual, 11/2024


reserved for troubleshooting. The example program also calls the instruction
"OPC_UA_MethodReleaseHandleList" to set the REQ parameter to FALSE.
If the output parameter "Done" is TRUE, the "OPC_UA_MethodReleaseHandleList" instruction was
executed successfully.
In the example, there is also a check to determine of the handle for the "OpenDoor" server
method has been released.
If executed successfully, the value of the "#State" tag is increased by one. This means the next
program section - case 6 - is executed in the next cycle.
Case 6 is described in OPC_UA_Disconnect: Close the connection.

Note
Case 6 is for enabling the connection to the OPC UA server. This also releases all
other resources that the client program has occupied in the server. If you want to
terminate the connection to the server, your user program can execute case 6
immediately and skip case 5.

1.1.1.8 System data types for OPC UA client instructions (S7-1500)

1.1.1.8.1 OPC_UA_SessionConnectInfo (S7-1500)

OPC_UA_SessionConnectInfo
See the following table for the meaning of the connection information for the
"SessionConnectInfo" parameter of the "OPC_UA_Connect" instruction.
Parameters of system data type "OPC_UA_SessionConnectInfo"

Parameter S7 data type Meaning

SessionName WSTRING[64] Name of the session, which you can enter here.
The parameter can be empty.
If you do not enter a name, the OPC UA server
assigns one.
The session name is used, for example, to identify
the connection for diagnostic purposes.

ApplicationName WSTRING[64] Name of the OPC UA client. The application name


is a component of the client description, which in
turn is a component of the session (see
SessionName). It is not possible to set a unique
ApplicationName for each session. The STRING
must be empty, otherwise error code
"Simatic_BadValue_VariantInput2 (0xB080_2200)"
is returned. The configured application name is
used as the ApplicationName for SIMATIC (CPU
parameters in the OPC UA area).

SecurityMsgMode UDINT Security process

Manual, 11/2024 185


0 = Best possible procedure Note: This
setting is not permitted!

1 = None

2 = Sign

3 = Sign&Encrypt

SecurityPolicy UDINT Securityprofile

0 = Best possible security profile Note: This


setting is not permitted!

1 = No security profile

2 = Basic128Rsa15

3 = Basic256

4 = Basic256Sha256

ServerUri STRING[254] Only relevant for connections to an OPC UA


server via a gateway server.
CPUs with firmware versions ≤ V2.6 do not
support gateway servers. This parameter
therefore must be supplied with an empty
string.

CheckServerCertificate BOOL If this bit is set, the client checks the certificate
sent by the server against the configured
trustworthy certificates. You can access the list
of trusted certificates via the properties of the
Client CPU > "Protection & Security" area >
Certificate Manager. There you can find the
"Certificates of the partner devices" table,
which you have to fill out.
The requirement for filling is that you have
imported the required certificates via the
global certificate manager (Project tree >
Certificate manager > "Trusted Certificates and
Root Certification Authorities" tab).
If the bit is not set, the client does not check
the server certificate.

TransportProfile UDINT 1 = UATP_UATcp


According to the PLCopen specification, only
this transport profile is supported.

186 Manual, 11/2024


UserIdentityTokenType UDINT For user authentication data, see the
explanation below this table.

UserTokenParam1 WSTRING[64] The meaning depends on


UserIdentityTokenType (for example user
name).

UserTokenParam2 WSTRING[64] The meaning depends on


UserIdentityTokenType (for example
password).

CertificateID UDINT The ID of the certificate that you use for the
OPC UA client.
You can find the ID in STEP 7 (TIA Portal)
under "Global security settings" > "Certificate
manager" > "Device certificates" and also in
the CPU properties ("Protection & Security" >
"Certificate Manager" area). There you can find
the "Device certificates" table with the IDs of
the certificates.
Proceed as follows to generate a certificate for
the client:

1. In the TIA Portal, select the properties of

the CPU that is used as the client.

2. If a self-signed certificate is sufficient for

you, skip this step. If you want to use a


certificate signed by a CA, then select the

"Use global security settings for certificate

manager" option under "Security" >


"Certificate manager" > "Global security

settings".

3. Navigate to the "Device certificates" table

and double-click on an empty field in the

"Certificate holder" column.


A certificate icon appears at the left edge

of the row.

4. Click on the "Certificate holder" field again.

A drop-down list opens showing the

existing device certificates.

Manual, 11/2024 187


5. Click on the "Add" button.
A dialog with setting options for the

certificate is displayed.

6. Select "OPC UA Client" or "OPC UA Client &

Server" for the use and then "OK".

SessionTimeout TIME Maximum time for which a session is


maintained after the connection to the OPC UA
server has been interrupted (in milliseconds).
Default setting: 20000 (20 seconds)

MonitorConnection TIME Connection monitoring time (in milliseconds)


Time interval for checking a connection over
which no data is currently being transferred.
Default setting: 5000 (5 seconds)

LocaleIDs ARRAY[1..5] of Optional language and regional identifier acc.


STRING[6] to RFC 3066.
0 = no or unknown LocaleID.

"UserIdentityTokenType" parameter
The following table shows the values possible for "UserIdentityTokenType" for S7-1500 CPUs and
the relationship between the "UserIdentityTokenType", "UserTokenParam1" and
"UserTokenParam2" parameters of the system data type "UASessionConnectInfo":

UserIdentityTokenType UserTokenParam1 UserTokenParam2 Description

0 Ignored Ignored Guest


authentication,
which means access
without
authentication.
(Anonymous user)

188 Manual, 11/2024


client only permits connection establishment
when the security policies ensure that the
user name and password are only transmitted
encrypted.
Recommendation: Use users from the user
administration of the project.

42 User name from the Ignored Simatic-specific value for


user administration UserIdentityTokenType. Authentication only
of the project for users from the user administration of the
(Security settings) project.
For users from the user administration of the
project, you download the password together
with the other user data and the configuration
data to the client CPU.
This way you protect the password from being
accessed from the outside. You must have
assigned the function right "User
authentication of the OPC UA client" to the
user in the project tree (Security settings >
Users and roles).
When you make the settings for user
authentication in the OPC UA client interface,
select the option "User (TIA Portal – Security
settings)" and enter a previously configured
user name.

65 User name Password Simatic-specific value for


UserIdentityTokenType.
The password is stored in plain text in the
corresponding global data block or instance
data block and can be read out.
An S7-1500 CPU as OPC UA client with this
UserIdentityTokenType also permits
connection establishment when no encrypted
connection is set, and the password is
therefore transmitted unencrypted.
Only use this UserIdentityTokenType when
the OPC UA server requires unencrypted
transmission and make sure that the
transmission takes place in a secured
environment.
Recommendation: Use users from the user
administration of the project.

See also
OPC_UA_Connect: Create connection

Manual, 11/2024 189


1.1.1.8.2 OPC_UA_NodeId (S7-1500)

OPC_UA_NodeId
See the following table for the meaning of the "OPC_UA_NodeId" parameters for identifying the
destination node in the OPC UA server. "OPC_UA_NodeId" supplies the "NodeIDs" parameter of
the "OPC_UA_NodeGetHandleList" instruction.
Parameters of system data type "OPC_UA_NodeId"

Parameter S7 data type Meaning

NamespaceIndex UINT Namespace index of the node in the OPC UA


server.
A node can, for example, be an object or a tag.

Identifier WSTRING[254] The designation of the node (object or tag)


depends on the identifier type:

Numeric identifier: The node is labeled with

a number, for example "12345678"


(STRING with converted DWORD).

String identifier: The node is labeled with a


name, for example "MyTag". Names are

case-sensitive.

For the names of nodes of "GUID" and

"Opaque" type, see below.

IdentifierType UDINT Type of identifier

0: Numeric identifier

1: String identifier

2: GUID

3: Opaque

Identifier of IdentifierType "GUID"


Format: {XXXXXXXX-XXXX-XXXX-XXXX-XXXXXXXXXXXX}
Example for entering the format of IdentifierType GUID (2) in STEP 7:
WSTRING#'5ce9dbce-5d79-434c-9ac3-1cfba9a6e92c'

Identifier of IdentifierType "Opaque"

190 Manual, 11/2024


Opaque identifiers are identifiers with an apparently random sequence of characters without
immediately recognizable semantics.
With OPC UA, you can generate an identifier of Opaque type by encoding any byte array of
defined length (e.g. ASCII string 'abcd' or the HEX counterpart (0x61626364) Base64. Numerous
tools are available for Base64 encoding.
Example for the format of IdentifierType Opaque (3) in STEP 7 after coding the HEX value:
WSTRING#'YWJjZA=='
The server displays the uncoded value of the identifier, in this case the HEX value.
See also
OPC_UA_NodeGetHandleList: Get handles for read and write access (S7-1500)

1.1.1.8.3 OPC_UA_NodeAdditionalInfo (S7-1500)

OPC_UA_NodeAdditionalInfo
Specifies attribute types and index range of nodes for the "NodeAddInfos" parameter of the
"OPC_UA_ReadList" and "OPC_UA_WriteList" instructions.

The data type is used for scalar values and one-dimensional arrays.

To read a section of a multi-dimensional array (up to six dimensions, (matrix)), use the

"OPC_UA_NodeAdditionalInfoExt" data type.

Read the information on Mapping SIMATIC data types to OPC UA data types.

The StartIndex must be greater than or equal to "0" and less than or equal to EndIndex.

Settings for the full reading of reading lists consisting of scalars and arrays:

If both StartIndex and EndIndex have the value 4_294_967_295 (UDINT_MAX), the server
ignores the value for StartIndex and EndIndex and fully reads scalars and arrays, see. Reading

array range information with OPC_UA_ReadList.

Parameters of system data type "OPC_UA_NodeAdditionalInfo"

Parameters Data type Meaning

AttributeId UDINT Specifies which attribute of a node (tag) is to be read.


The IDs of the attributes are defined in the OPC UA
enumeration type "UAAttributeId".
Examples:

5: Description (Description)

13: Value (value)

14: DataType (Data type)

Manual, 11/2024 191


15: ValueRank (number of dimensions in the Value attribute)

16: ArrayDimensions (length of a dimension, number of

elements)

The default is 13 (Value).

StartIndex UDINT When AttributeId = 13: The start index of an array. Values are read
starting at this index.

EndIndex UDINT When AttributeId = 13: The end index of an array. Values are read
to this index.

See also
OPC_UA_NodeAdditionalInfoExt (S7-1500)

1.1.1.8.4 OPC_UA_NodeAdditionalInfoExt (S7-1500)

OPC_UA_NodeAdditionalInfoExt
Specifies the attribute of the node and the index are for the "NodeAddInfos" parameter
("OPC_UA_ReadList" and "OPC_UA_WriteList" instructions).
Parameters of system data type "OPC_UA_NodeAdditionalInfoExt"

Parameter S7 data Meaning


type

AttributeID UDINT Specifies which attribute of a node (tag) is to be read


or written.
The default is 13 (Value).

IndexRangeCount UDINT Number of the following index ranges.


You do not need to specify all six index ranges.

StartIndex1 UDINT The index from which values for array dimension 1 are
to be read or written.

EndIndex1 UDINT The index up to which values for array dimension 1


are to be read or written.

StartIndex2 UDINT The index from which values for array dimension 2 are
to be read or written.

EndIndex2 UDINT The index up to which values for array dimension 2


are to be read or written.

192 Manual, 11/2024


StartIndex3 UDINT The index from which values for array dimension 3 are to be
read or written.

EndIndex3 UDINT The index up to which values for array dimension 3 are to be
read or written.

StartIndex4 UDINT The index from which values for array dimension 4 are to be
read or written.

EndIndex4 UDINT The index up to which values for array dimension 4 are to be
read or written.

StartIndex5 UDINT The index from which values for array dimension 5 are to be
read or written.

EndIndex5 UDINT The index up to which values for array dimension 5 are to be
read or written.

StartIndex6 UDINT The index from which values for array dimension 6 are to be
read or written.

EndIndex6 UDINT The index up to which values for array dimension 6 are to be
read or written.

See also
OPC_UA_NodeAdditionalInfo (S7-1500)

1.1.1.8.5 OPC_UA_BrowsePath (S7-1500)

OPC_UA_BrowsePath
See the following table for the structure of the system data type "OPC_UA_BrowsePath":
Parameters of system data type "OPC_UA_BrowsePath"

Name Data type Meaning

StartingNode OPC_UA_NodeId NodeId of the node (or tag) at


which the path starts.
Browsing is to be from this
node on.

RelativePath OPC_UA_RelativePath The relative path for browsing;


see OPC_UA_RelativePath.

1.1.1.8.6 OPC_UA_RelativePath (S7-1500)

OPC_UA_RelativePath

Manual, 11/2024 193


See the following table for the structure of the system data type "OPC_UA_RelativePath":
Parameters of system data type "OPC_UA_RelativePath"

Name Data type Meaning

NoOfElements UINT Number of elements in


Elements

Elements Array [4] of Array with up to four elements


OPC_UA_RelativePathElement of the type
OPC_UA_RelativePathElement

1.1.1.8.7 OPC_UA_RelativePathElement (S7-1500)

OPC_UA_RelativePathElement
See the following table for the structure of the system data type "OPC_UA_RelativePathElement":
Parameters of system data type "OPC_UA_RelativePathElement"

Name Data type Meaning

ReferenceTypeId OPC_UA_NodeId The reference type to be


followed in this
RelativePathElement.
ReferenceTypeId is set by
default for hierarchical
references.

IsInverse BOOL If TRUE, the inverse direction is


followed.
The default is FALSE.

IncludeSubtypes BOOL If TRUE, the reference types


derived from the type specified
under ReferenceTypeId are also
followed.
The default is TRUE.

TargetName OPC_UA_QualifiedName See system data type


OPC_UA_QualifiedName

1.1.1.8.8 OPC_UA_QualifiedName (S7-1500)

OPC_UA_QualifiedName
See the following table for the structure of the system data type "OPC_UA_QualifiedName":
Parameters of system data type "OPC_UA_QualifiedName"

194 Manual, 11/2024


Name Data type Meaning

NamespaceIndex UINT The namespace index of the


name.

Name WSTRING[64] BrowseName of the node (or


tag).

1.1.1.9 Error codes (S7-1500)

1.1.1.9.1 Siemens error codes (S7-1500)

SIMATIC status codes for OPC UA instructions


The table below lists the Siemens error codes for the OPC UA client instructions:

Status code Meaning

B080_0100 BadType_VariantInput1:
The data type of the tag to which the first variant
parameter of the instruction is pointing is incorrect.
An example:
For the instruction "OPC_UA_Connect", the parameter
"ServerEndpointUrl" is the first variant parameter.
The order of VariantInput1 to VariantInput5 corresponds
to the order of the variant parameters in the
documentation for the respective OPC UA instruction.
If the first variant parameter points to a tag that has the
incorrect data type, the status code "B080_0100" is
returned.
The correct data type is listed in the "Parameter" table of
the respective instruction.
In the example, you can find the data type of the
'Parameter for "OPC_UA_Connect"' table in the section on
the instruction "OPC_UA_Connect: Create connection".

B080_0200 BadType_VariantInput2.
The data type of the tag to which the second variant
parameter of the instruction is pointing is incorrect.

B080_0300 BadType_VariantInput3:
The data type of the tag to which the third variant
parameter of the instruction is pointing is incorrect.

B080_0400 BadType_VariantInput4:

Manual, 11/2024 195


The data type of the tag to which the fourth variant parameter of the
instruction is pointing is incorrect.

B080_0500 BadType_VariantInput5:
The data type of the tag to which the fifth variant parameter of the
instruction is pointing is incorrect.

B080_3100 BadNumElements_VariantInput1:
Number of array elements in variant 1 is smaller than the number stored
in the count parameter of the instruction (e.g. NodeIDCount for
OPC_UA_NodeGetHandleList or NamespaceUrisCount for
OPC_UA_NamespaceGetIndexList, etc.).

B080_3200 BadNumElements_VariantInput2:
Number of array elements in variant 2 is smaller than the number stored
in the count parameter of the instruction.

B080_3300 BadNumElements_VariantInput3:
Number of array elements in variant 3 is smaller than the number stored
in the count parameter of the instruction.

B080_3400 BadNumElements_VariantInput4:
Number of array elements in variant 4 is smaller than the number stored
in the count parameter of the instruction.

B080_3500 BadNumElements_VariantInput5:
Number of array elements in variant 5 is smaller than the number stored
in the count parameter of the instruction.

B080_C400 Simatic_ClientNotEnabled:
The OPC UA client is disabled.

B080_C500 SimaticNothingToDo:
Error during initialization of the client

B080_C600 ClientNotAvailable
Error during initialization of the client

B080_0B00 ArrayElements_TooMany:
The array has too many elements.

B080_1100 ArrayElements_TooMany:
General error code. Occurs when an array has too many elements:
NamespaceUrisCount > MAX_ELEMENTS_NAMESPACES
NodeIDCount > MAX_ELEMENTS_NODELIST

196 Manual, 11/2024


BrowsePathscount > MAX_ELEMENTS_RELATIVEPATH
MethodHdlCount > MAX_ELEMENTS_METHODLIST
MAX_ELEMENTS_NAMESPACES = 20
MAX_ELEMENTS_NODELIST = 300
MAX_ELEMENTS_METHODLIST = 100
MAX_ELEMENTS_BROWSEPATH = 10

B080_1200 ArrayElements_TooFew

B080_2100 BadValue_VariantInput1:
The value of the tag to which the first variant of the instruction is pointing
is incorrect.

B080_2200 BadValue_VariantInput2:
The value of the tag to which the second variant of the instruction is
pointing is incorrect.

B080_2300 BadValue_VariantInput3:
The value of the tag to which the third variant of the instruction is
pointing is incorrect.

B080_2400 BadValue_VariantInput4:
The value of the tag to which the fourth variant of the instruction is
pointing is incorrect.

B080_2500 BadValue_VariantInput5:
The value of the tag to which the fifth variant of the instruction is
pointing is incorrect.

B080_B000 TooManyMethods:
Maximum number of server methods or max. number of server method
instances exceeded.
(Calls of the instructions OPC_UA_ServerMethodPre,
OPC_UA_ServerMethodPost):
Refer to the technical specifications of the CPUs (number of server
methods, max.)

C080_C300 InsufficientResources:
Insufficient resources. Either (a) error upon memory allocation or (b) too
many SFB instances

1.1.1.9.2 Error codes of the OPC Foundation (S7-1500)

Error codes

Manual, 11/2024 197


The names and explanations of the errors are listed in the original (English) and are selectively
supplemented with additional information.

Error codes

Status "Good" (0000_0000 - 3FFF_FFFF)

Error code Name Meaning


(hex)

0000_0000 Good Success, no error.

002D_0000 GoodSubscriptionTransferred The subscription was transferred to


another session.

002E_0000 GoodCompletesAsynchronously The processing will complete


asynchronously.

002F_0000 GoodOverload Sampling has slowed down due to


resource limitations.

0030_0000 GoodClamped The value written was accepted but


was clamped.

0096_0000 GoodLocalOverride The value has been overridden.

00A2_0000 GoodEntryInserted The data or event was successfully


inserted into the historical database.

00A3_0000 GoodEntryReplaced The data or event field was


successfully replaced in the historical
database.

00A5_0000 GoodNoData No data exists for the requested time


range or event filter.

00A6_0000 GoodMoreData The data or event field was


successfully replaced in the historical
database.

00A7_0000 GoodCommunicationEvent The communication layer has raised an


event.

00A8_0000 GoodShutdownEvent The system is shutting down.

00A9_0000 GoodCallAgain The operation is not finished and


needs to be called again.

198 Manual, 11/2024


00AA_0000 GoodNonCriticalTimeout A non-critical timeout occurred.

00BA_0000 GoodResultsMayBeIncomplete The server should have followed a


reference to a node in a remote server
but did not. The result set may be
incomplete.

00D9_0000 GoodDataIgnored The request pecifies fields which are


not valid for the EventType or cannot
be saved by the historian.

00DC_0000 GoodEdited The value does not come from the real
source and has been edited by the
server.

00DD_0000 GoodPostActionFailed There was an error in execution of


these post-actions.

00E0_0000 GoodDependentValueChanged A dependent value has been changed


but the change has not been applied to
the device.

Status "Uncertain" (4000_0000 - 7FFF_FFFF)

Error code Name Meaning


(hex)

406C_0000 UncertainReferenceOutOfServer One of the references to


follow in the relative path
references to a node in
the address space in
another server.

408F_0000 UncertainNoCommunicationLastUsableValue Communication to the


data source has failed.
The variable value is the
last value that had a good
quality.

4090_0000 UncertainLastUsableValue Whatever was updating


this value has stopped
doing so.

Manual, 11/2024 199


4091_0000 UncertainSubstituteValue The value is an operational value
that was manually overwritten.

4092_0000 UncertainInitialValue The value is an initial value for a


variable that normally receives its
value from another variable.

4093_0000 UncertainSensorNotAccurate The value is at one of the sensor


limits.

4094_0000 UncertainEngineeringUnitsExceeded The value is outside of the range


of values defined for this
parameter.

4095_0000 UncertainSubNormal The value is derived from multiple


sources and has less than the
required number of Good sources.

40A4_0000 UncertainDataSubNormal The value is derived from multiple


values and has less than the
required number of Good values.

40BC_0000 UncertainReferenceNotDeleted The server was not able to delete


all target references.

40C0_0000 UncertainNotAllNodesAvailable The list of references may not be


complete because the underlying
system is not available.

40DE_0000 UncertainDominantValueChanged The related EngineeringUnit has


been changed but the Variable
Value is still provided based on
the previous unit.

40E2_0000 UncertainDependentValueChanged A dependent value has been


changed but the change has not
been applied to the device. The
quality of the dominant variable is
uncertain.

Status "Bad" (8000_0000 - FFFF_FFFF)

Error code Name Meaning


(hex)

8001_0000 BadUnexpectedError An unexpected error occurred

200 Manual, 11/2024


Possible cause:
You have write-accessed a single element of a
tag of data type DTL. Write access to tags of
data type DTL is only possible to the complete
structure.

8003_0000 BadOutOfMemory Not enough memory to complete the


operation.
Possible cause:
The maximum quantity structure of the OPC
UA server has been exceeded.
Solution:
Reduce the number of registered OPC UA
elements.
Use an OPC UA Server diagnostics tool (such
as UaExpert from Unified Automation) to
ensure that there are no inactive sessions and
subscriptions. As countermeasure you can
select corresponding timeouts (Subscription
Timeout <= Session Timeout) in the client.
See also the description to the error messages
OPC_UA_Connect: Create connection.

8004_0000 BadResourceUnavailable An operating system resource is not available

8005_0000 BadCommunicationError A low level communication error occurred.


Possible cause:
The server address (ServerEndpointURL) is
incorrect or incomplete.
See also the explanation for this parameter in
OPC_UA_Connect: Create connection.

8006_0000 BadEncodingError Encoding halted because of invalid data in


the objects being serialized.

8007_0000 BadDecodingError Decoding halted because of invalid data in


the stream.

8008_0000 BadEncodingLimits­‐ The message encoding/decoding limits


Exceeded imposed by the stack have been exceeded.

8009_0000 BadUnknownResponse An unrecognized response was received from


the server.

80B8_0000 BadRequestTooLarge The request message size exceeds limits set


by the server.

Manual, 11/2024 201


80B9_0000 BadResponseTooLarge The response message size exceeds limits set
by the client.

800A_0000 BadTimeout The operation timed out.


See also error message at OPC_UA_Connect:
Create connection.

800B_0000 BadServiceUnsupported The server does not support the requested


service.

800C_0000 BadShutdown The operation was cancelled because the


application is shutting down.

800D_0000 BadServerNotConnected The operation could not complete because


the client is not connected to the server.

800E_0000 BadServerHalted The server has stopped and cannot process


any requests.

800F_0000 BadNothingToDo There was nothing to do because the client


passed a list of operations with no elements.

8010_0000 BadTooManyOperations The request could not be processed because


it specified too many operations.
See also error message at
OPC_UA_NamespaceGetIndexList: Read
namespace indexes.

8011_0000 BadDataTypeIdUnknown The extension object cannot be (de)serialized


because the data type id is not recognized.

8012_0000 BadCertificateInvalid The certificate provided as a parameter is not


valid.

8013_0000 BadSecurityChecksFailed An error occurred verifying security. The


certificate provided as a parameter is not
valid.

8014_0000 BadCertificateTimeInvalid The Certificate has expired or is not yet valid.

8015_0000 BadCertificateIssuer An Issuer Certificate has expired or is not yet


TimeInvalid valid.

8016_0000 BadCertificateHost The HostName used to connect to a Server


NameInvalid does not match a HostName in the
Certificate.

202 Manual, 11/2024


Certificate.

8018_0000 BadCertificateUseNotAllowed The Certificate may not be used for the


requested operation.

8019_0000 BadCertificateIssuerUse The Issuer Certificate may not be used for


NotAllowed the requested operation.

801A_0000 BadCertificateUntrusted The Certificate is not trusted.

801B_0000 BadCertificateRevocation It was not possible to determine if the


Unknown Certificate has been revoked.

801C_0000 BadCertificateIssuer It was not possible to determine if the


RevocationUnknown Issuer
Certificate has been revoked.

801D_0000 BadCertificateRevoked The Certificate has been revoked.

801E_0000 BadCertificateIssuerRevoked The Issuer Certificate has been revoked.

801F_0000 BadUserAccessDenied User does not have permission to


perform the requested operation.

8020_0000 BadIdentityTokenInvalid The user identity token is not valid.

8021_0000 BadIdentityTokenRejected The user identity token is valid but the


server has rejected it.

8022_0000 BadSecureChannelIdInvalid The specified secure channel is no longer


valid.

8023_0000 BadInvalidTimestamp The timestamp is outside the range


allowed by the server.

8024_0000 BadNonceInvalid The nonce does appear to be not a


random value or it is not the correct
length.

8025_0000 BadSessionIdInvalid The session id is not valid.

8026_0000 BadSessionClosed The session was closed by the client.

8027_0000 BadSessionNotActivated The session cannot be used because


ActivateSession has not been called.

8028_0000 BadSubscriptionIdInvalid The subscription id is not valid.

Manual, 11/2024 203


802A_0000 BadRequestHeaderInvalid The header for the request is missing or
invalid.

802B_0000 BadTimestampsTo The timestamps to return parameter is


ReturnInvalid invalid.

802C_0000 BadRequestCancelled The request was cancelled by the client.


ByClient

8031_0000 BadNoCommunication Communication with the data source is


defined, but not established, and there is no
last known value available.

8032_0000 BadWaitingForInitialData Waiting for the server to obtain values from


the underlying data source.

8033_0000 BadNodeIdInvalid The syntax of the node id is not valid.

8034_0000 BadNodeIdUnknown The node id refers to a node that does not


exist in the server address space.
The NamespaceIndex of the specified NodeId
may not exist. If the error code is displayed
when the instruction "OPC_UA_MethodCall"
is called:
Another possible cause is the use of invalid
ObjectIDs in the preceding call of
OPC_UA_MethodGetHandleList. The
instruction "OPC_UA_MethodGetHandleList"
does not evaluate the ObjectIds.

8035_0000 BadAttributeIdInvalid The attribute is not supported for the


specified Node.

8036_0000 BadIndexRangeInvalid The syntax of the index range parameter is


invalid.

8037_0000 BadIndexRangeNoData No data exists within the range of indexes


specified.

8038_0000 BadDataEncodingInvalid The data encoding is invalid.

8039_0000 BadDataEncoding The server does not support the requested


Unsupported data encoding for the node.

803A_0000 BadNotReadable The access level does not allow reading or


subscribing to the Node.

204 Manual, 11/2024


803B_0000 BadNotWritable The access level does not allow writing to
the Node.

803C_0000 BadOutOfRange The value was out of range.


Possible remedy for arrays: Check whether
you can access elements of an array that
are undefined.

803D_0000 BadNotSupported The requested operation is not supported.


Possible cause:
The server address (ServerEndpointURL) is
incorrect or incomplete.

803E_0000 BadNotFound A requested item was not found or a search


operation ended without success.

803F_0000 BadObjectDeleted The object cannot be used because it has


been deleted.

8040_0000 BadNotImplemented Requested operation is not implemented.

8041_0000 BadMonitoringModeInvalid The monitoring mode is invalid.

8042_0000 BadMonitoredItemIdInvalid The monitoring item id does not refer to a


valid monitored item.

8043_0000 BadMonitoredItem The monitored item filter parameter is not


FilterInvalid valid.

8044_0000 BadMonitoredItem The server does not support the requested


FilterUnsupported monitored item filter.

8045_0000 BadFilterNotAllowed A monitoring filter cannot be used in


combination with the attribute specified.

8046_0000 BadStructureMissing A mandatory structured parameter was


missing or null.

8047_0000 BadEventFilterInvalid The event filter is not valid.

8048_0000 BadContentFilterInvalid The content filter is not valid.

8049_0000 BadFilterOperandInvalid The operand used in a content filter is not


valid.

804A_0000 BadContinuation The continuation point provide is longer


PointInvalid valid.

Manual, 11/2024 205


804B_0000 BadNoContinuationPoints The operation could not be processed
because all continuation points have been
allocated.

804C_0000 BadReferenceTypeIdInvalid The operation could not be processed


because all continuation points have been
allocated.

804D_0000 BadBrowseDirectionInvalid The browse direction is not valid.

804E_0000 BadNodeNotInView The node is not part of the view.

804F_0000 BadServerUriInvalid The ServerUri is not a valid URI.

8050_0000 BadServerNameMissing No ServerName was specified

8051_0000 BadDiscoveryUrlMissing No DiscoveryUrl was specified.

8052_0000 BadSempahoreFileMissing The semaphore file specified by the client is


not valid.

8053_0000 BadRequestTypeInvalid The security token request type is not valid.

8054_0000 BadSecurityModeRejected The security mode does not meet the


requirements set by the Server.
Server is setting higher security
requirements. Possible remedy: Use a
higher security setting for the connection to
the server.

8055_0000 BadSecurityPolicyRejected The security policy does not meet the


requirements set by the Server.

8056_0000 BadTooManySessions The server has reached its maximum


number of sessions.

8057_0000 BadUserSignatureInvalid The user token signature is missing or


invalid.

8058_0000 BadApplicationSignature The signature generated with the client


Invalid certificate is missing or invalid.

8059_0000 BadNoValidCertificates The client did not provide at least one


software certificate that is valid and meets
the profile requirements for the server.

805A_0000 BadRequestCancelled The request was cancelled by the client


ByRequest with the Cancel service.

206 Manual, 11/2024


805B_0000 BadParentNodeIdInvalid The parent node id does not to refer to a
valid node.

805C_0000 BadReferenceNotAllowed The reference could not be created


because it violates constraints imposed by
the data model.

805D_0000 BadNodeIdRejected The requested node id was reject because


it was either invalid or server does not
allow node ids to be specified by the client.

805E_0000 BadNodeIdExists The requested node id is already used by


another node.

805F_0000 BadNodeClassInvalid The node class is not valid.

8060_0000 BadBrowseNameInvalid The browse name is invalid.

8061_0000 BadBrowseNameDuplicated The browse name is not unique among


nodes that share the same relationship
with the parent.

8062_0000 BadNodeAttributesInvalid The node attributes are not valid for the
node class.

8063_0000 BadTypeDefinitionInvalid The type definition node id does not


reference an appropriate type node.

8064_0000 BadSourceNodeIdInvalid The source node id does not reference a


valid node.

8065_0000 BadTargetNodeIdInvalid The target node id does not reference a


valid node.

8066_0000 BadDuplicateReference The reference type between the nodes is


NotAllowed already defined.

8067_0000 BadInvalidSelfReference The server does not allow this type of


selfreference on this node.

8068_0000 BadReferenceLocalOnly The reference type is not valid for a


reference to a remote server.

8069_0000 BadNoDeleteRights The server will not allow the node to be


deleted.

806A_0000 BadServerIndexInvalid The server index is not valid.

Manual, 11/2024 207


806B_0000 BadViewIdUnknown The view id does not refer to a valid view
node.

806D_0000 BadTooManyMatches The requested operation has too many


matches to return.

806E_0000 BadQueryTooComplex The requested operation requires too many


resources in the server.

806F_0000 BadNoMatch The requested operation has no match to


return.

8070_0000 BadMaxAgeInvalid The max age parameter is invalid.

8071_0000 BadHistoryOperationInvalid The history details parameter is not valid.

8072_0000 BadHistoryOperation The server does not support the requested


Unsupported operation.

8073_0000 BadWriteNotSupported The server not does support writing the


combination of value, status and
timestamps provided.

8074_0000 BadTypeMismatch The value supplied for the attribute is not


of the same type as the attribute's value.

8075_0000 BadMethodInvalid The method id does not refer to a method


for the specified object.

8076_0000 BadArgumentsMissing The client did not specify all of the input
arguments for the method.

8077_0000 BadTooManySubscriptions The server has reached its maximum


number of subscriptions.
Possible cause:
Maximum number of subscriptions is
exceeded
Solution:
Create a subscription in a new session.

8078_0000 BadTooManyPublish The server has reached the maximum


Requests number of queued publish requests.

8079_0000 BadNoSubscription There is no subscription available for this


session.

208 Manual, 11/2024


807A_0000 BadSequenceNumber The sequence number is unknown to the
Unknown server.

807B_0000 BadMessageNotAvailable The requested notification message is no


longer available.

807C_0000 BadInsufficientClientProfile The Client of the current Session does not


support one or more Profiles that are
necessary for the Subscription.

80BF_0000 BadStateNotActive The sub-state machine is not currently


active.

807D_0000 BadTcpServerTooBusy The server cannot process the request


because it is too busy.

807E_0000 BadTcpMessageTypeInvalid The type of the message specified in the


header invalid.

807F_0000 BadTcpSecureChannel The SecureChannelId and/or TokenId are


Unknown not currently in use.

8080_0000 BadTcpMessageTooLarge The size of the message specified in the


header is too large.

8081_0000 BadTcpNotEnough There are not enough resources to process


Resources the request.
See also error message at
OPC_UA_Connect: Create connection.

8082_0000 BadTcpInternalError An internal error occurred.

8083_0000 BadTcpEndpointUrlInvalid The Server does not recognize the


QueryString specified.

8084_0000 BadRequestInterrupted The request could not be sent because of


a network interruption.

8085_0000 BadRequestTimeout Timeout occurred while processing the


request.

8086_0000 BadSecureChannelClosed The secure channel has been closed.

8087_0000 BadSecureChannelToken The token has expired or is not


Unknown recognized.

8088_0000 BadSequenceNumberInvalid The sequence number is not valid.

Manual, 11/2024 209


8089_0000 BadConfigurationError There is a problem with the
configuration that affects the usefulness
of the value.

808A_0000 BadNotConnected The variable should receive its value


from another variable, but has never
been configured to do so.

808B_0000 BadDeviceFailure There has been a failure in the


device/data source that generates the
value that has affected the value.

808C_0000 BadSensorFailure There has been a failure in the sensor


from which the value is derived by the
device/data source.

808D_0000 BadOutOfService The source of the data is not operational.

808E_0000 BadDeadbandFilterInvalid The dead band filter is not valid.

8097_0000 BadRefreshInProgress This Condition refresh failed, a Condition


refresh operation is already in progress.

8098_0000 BadConditionAlreadyDisabled This condition has already been disabled.

8099_0000 BadConditionDisabled Property not available, this condition is


disabled.

809A_0000 BadEventIdUnknown The specified event id is not recognized.

809B_0000 BadNoData No data exists for the requested time


range or event filter.

809D_0000 BadDataLost Data is missing due to collection


started/stopped/lost.

809E_0000 BadDataUnavailable Expected data is unavailable for the


requested time range due to an
unmounted volume an off-line archive or
tape or similar reason for temporary
unavailability.

809F_0000 BadEntryExists The data or event was not successfully


inserted because a matching entry
exists.

210 Manual, 11/2024


80A1_0000 BadTimestampNotSupported The client requested history using a
timestamp format the server does not
support (i. e. requested ServerTimestamp
when server only supports
SourceTimestamp).

80AB_0000 BadInvalidArgument One or more arguments are invalid.


Possible cause:
The server address (ServerEndpointURL)
is incorrect or incomplete.

80AC_0000 BadConnectionRejected Could not establish a network connection


to remote server.

80AD_0000 BadDisconnect The server has disconnected from the


client.

80AE_0000 BadConnectionClosed The network connection has been closed.


The connection with the corresponding
ConnectionHdl has the "ShutDown"
status (connection terminated). The
connection/session could not be
"reactivated" automatically. Possible
cause: Session deleted on the server, e.g.
due to restart or timeout.
In this case, you must explicitly close the
connection with the instruction
"OPC_UA_Disconnect" and thereby
release the connection resources again.
In your user program, you must reset the
ConnectionHdl for this connection which
has become invalid.
Then you have to establish a new
connection to the server (see instruction
"OPC_UA_Connect").
The error code can occur in all client
instructions except the OPC_UA_Connect,
OPC_UA_Disconnect, and
OPC_UA_ConnectionGetStatus
instructions.

80AF_0000 BadInvalidState The operation cannot be completed


because the object is closed uninitialized
or in some other invalid state.
The connection with the corresponding
ConnectionHdl has the "ConnectionError"
status (temporary connection error,
connection interrupted). The CPU tries to
"reactivate" the connection. If this does
not succeed within the set timeout

Manual, 11/2024 211


interval (OPC UA Session Timeout), the
connection goes into the "Shutdown" state.
Requirements for the state transition: The
CPU was able to reach the OPC UA server to
check whether or not the session is still
active.
The error code can occur in all client
instructions except the OPC_UA_Connect,
OPC_UA_Disconnect, and
OPC_UA_ConnectionGetStatus
instructions.

80B0_0000 BadEndOfStream Cannot move beyond end of the stream.

80B1_0000 BadNoDataAvailable No data is currently available for reading


from a non-blocking stream.

80B2_0000 BadWaitingForResponse The asynchronous operation is waiting for


a response.

80B3_0000 BadOperationAbandoned The asynchronous operation was


abandoned by the caller.

80B4_0000 BadExpectedStreamToBlock The stream did not return all data


requested (possibly because it is a non-
blocking stream).

80B5_0000 BadWouldBlock Non-blocking behavior is required and the


operation would block.

80B6_0000 BadSyntaxError A value had an invalid syntax.

80B7_0000 BadMaxConnections The operation could not be finished


Reached because all available connections are in
use.

80BB_0000 BadEventNot The event cannot be acknowledged.


Acknowledgeable

80BD_0000 BadInvalidTimestamp The defined timestamp to return was


Argument invalid.

80BE_0000 BadProtocolVersion The applications do not have compatible


Unsupported protocol versions.

80C1_0000 BadFilterOperatorInvalid An unrecognized operator was provided in


a filter.

212 Manual, 11/2024


80C2_0000 BadFilterOperator A valid operator was provided, but
Unsupported the server does not provide support
for this filter operator.

80C3_0000 BadFilterOperandCount The number of operands provided for


Mismatch the filter operator was less than
expected for the operand provided.

80C4_0000 BadFilterElementInvalid The referenced element is not a valid


element in the content filter.

80C5_0000 BadFilterLiteralInvalid The referenced literal is not a valid


value.

80C6_0000 BadIdentityChangeNotSupported The Server does not support


changing the user identity assigned
to the session.

80C8_0000 BadNotTypeDefinition The provided NodeId was not a type


definition NodeId.

80C9_0000 BadViewTimestampInvalid The view timestamp is not available


or not supported.

80CA_0000 BadViewParameterMismatch The view parameters are not


consistent with each other.

80CB_0000 BadViewVersionInvalid The view version is not available or


not supported.

80CC_0000 BadConditionAlready This condition has already been


Enabled enabled.

80CD_0000 BadDialogNotActive The dialog condition is not active.

80CE_0000 BadDialogResponseInvalid The response is not valid for the


dialog.

80CF_0000 BadConditionBranch The condition branch has already


AlreadyAcked been acknowledged.

80D0_0000 BadConditionBranch The condition branch has already


AlreadyConfirmed been confirmed.

80D1_0000 BadConditionAlreadyShelved The condition has already been


shelved.

Manual, 11/2024 213


80D2_0000 BadConditionNotShelved The condition is not currently shelved.

80D3_0000 BadShelvingTimeOutOfRange The shelving time not within an


acceptable range.

80D4_0000 BadAggregateListMismatch The requested number of Aggregates


does not match the requested number of
NodeIds.

80D5_0000 BadAggregateNotSupported The requested Aggregate is not support


by the server.

80D6_0000 BadAggregateInvalidInputs The aggregate value could not be


derived due to invalid data inputs.

80DB_0000 BadTooManyMonitoredItems The request could not be processed


because there are too many monitored
items in the subscription.
Possible cause:
The maximum number of supervised
elements has been reached in a
subscription.
Solution:
To register additional elements, you
must create a new subscription.
For projects as of TIA Portal V15 and
higher, you can also set the maximum
number of supervised elements in the
CPU configuration.
Additional possible cause:
Request with too many elements
Solution:
Note the maximum values specified on
the server in the "ServerCapabilities"
object.

80D7_0000 BadBoundNotFound No data found to provide upper or lower


bound value.

80D8_0000 BadBoundNotSupported The server cannot retrieve a bound for


the variable.

80DA_0000 BadAggregateConfiguration The aggregate configuration is not valid


Rejected for specified node.

80E1_0000 BadDominantValueChanged The related EngineeringUnit has been


changed but this change has not been
applied to the device. The Variable Value

214 Manual, 11/2024


is still dependent on the previous unit
but its status is currently bad.

80E3_0000 BadDependentValueChanged A dependent value has been changed


but the change has not been applied to
the device. The quality of the dominant
variable is bad.

80E4_0000 BadRequestNotAllowed The request was rejected by the server


because it did not meet the criteria set
by the server.

80E5_0000 BadTooManyArguments Too many arguments were provided.

80E6_0000 BadSecurityModeInsufficient The operation is not permitted over the


current secure channel.

810D_0000 BadCertificateChainIncomplete The certificate chain is incomplete.

810E_0000 BadLicenseExpired The server requires a license to operate


in general or to perform a service or
operation, but existing license is
expired.

810F_0000 BadLicenseLimitsExceeded The server has limits on number of


allowed operations / objects, based on
installed licenses, and these limits
where exceeded.

8110_0000 BadLicenseNotAvailable The server does not have a license


which is required to operate in general
or to perform a service or operation.

8111_0000 BadNotExecutable The executable attribute does not allow


the execution of the method.

8112_0000 BadNumericOverflow The number was not accepted because


of a numeric overflow.

8113_0000 BadRequestNotComplete The request has not been processed by


the server yet.

1.1.1.9.3 PLCopen error codes (S7-1500)

Error codes
The following table contains PLCopen error codes.
The names and explanations of the errors are listed in the original. They are only available in
English.

Manual, 11/2024 215


PLCopen error codes

ErrorID Name Meaning


(hex)

A000_0001 PLCopenUA_Bad_FW_ Internal, permanent error.


PermanentError

A000_0002 PLCopenUA_Bad_FW_ Temp. Error; FB could retry to reach FW.


TempError

A000_0100 PLCopenUA_Bad_ Connection could not be established.


ConnectionError

A000_0101 PLCopenUA_Bad_ The requested hostname could not be found.


HostNotFound

A000_0102 PLCopenUA_Bad_ Connection was already established.


AlreadyConnected

A000_0103 PLCopenUA_Bad_ Connection failed due to security setup.


SecurityFailed

A000_0104 PLCopenUA_Bad_ Connection is suspended.


Suspended

A000_0105 PLCopenUA_Bad_ Provided ConnectionHdl is not known.


ConnectionInvalidHdl The connection handle (ConnectionHdl) is
invalid / unknown.
The error code can occur in all client instructions
except the OPC_UA_Connect instruction.
Additional information can be found in the
description of the error codes of the instruction
"OPC_UA_ConnectionGetStatus"

A000_0200 PLCopenUA_Bad_ A namespace with the requested name cannot


NSNotFound be found on server.

A000_0300 PLCopenUA_Bad_ Target PLC variable is too short for retrieved data.
ResultTooLong

A000_0301 PLCopenUA_Bad_ Invalid or unsupported Type.


InvalidType

A000_0302 PLCopenUA_Bad_ Provided NodeHdl is not known.


NodeInvalidHdl

216 Manual, 11/2024


A000_0303 PLCopenUA_Bad_ Provided MethodHdl is not known.
MethodInvalidHdl

A000_0304 PLCopenUA_Bad_ Read failed for unknown reason.


ReadFailed

A000_0305 PLCopenUA_Bad_ Write failed for unknown reason.


WriteFailed

A000_0306 PLCopenUA_Bad_ Method Call failed for unknown reason.


CallFailed

A000_0307 PLCopenUA_Bad_ Method Call Input parameter conversion


InParamFailed failed.

A000_0308 PLCopenUA_Bad_ Method Call Output parameter conversion


OutParamFailed failed. ATTENTION: this means the
MethodCall was executed successfully but the
returned values could not be converted.

A000_0500 PLCopenUA_Bad_ Provided SubscriptionHdl is not known.


SubscriptionInvalidHdl

A000_0501 PLCopenUA_Bad_ Provided MonitoredItemHdl is not known.


MonitoredItemInvalidHdl

1.1.1.10 Example programs for OPC UA clients (S7-1500)

1.1.1.10.1 Preliminary remarks (S7-1500)

The example function blocks "Call_OpenDoor_On_Productionline", "ReadFromProductionline"


and "WriteToProductionline" only illustrate the individual functions and are not designed for
common use. They can therefore only run individually.
Each FB establishes its own connection with the OPC_UA_Connect instruction and accesses the
same client interface and thus the DB "Productionline_Configuration".
The connection handles of the three connections are stored in the same tag when used together
and overwrite each other.
Take this fact into account when using all the functions described in your project.

1.1.1.10.2 Example program for OPC_UA_ConnectionGetStatus (S7-1500)

Example program for analyzing connections


This section includes the complete program code for the example program
"Analyze_Connection".
The example shows you how a user program uses the instruction
"OPC_UA_ConnectionGetStatus" to get information about a connection to an OPC UA server.
You can find a description of the "OPC_UA_ConnectionGetStatus" instruction in section
OPC_UA_ConnectionGetStatus: Read connection status.

Manual, 11/2024 217


Program structure
The program operates as OPC UA client and comprises the following sections:

1. Establishing a connection to an OPC UA server.

2. Analyzing the connection.

3. Terminating the connection to the OPC UA server.

You start the program with a positive edge at "Input_REQ".

Declaration
The following figure shows the declaration of local tags of a function block that uses the
instruction "OPC_UA_ConnectionGetStatus":

218 Manual, 11/2024


Program

SCL

IF #Run = FALSE THEN


#Started := #Input_REQ AND NOT #Mem_Input_REQ;
#Mem_Input_REQ := #Input_REQ;
IF #Started THEN
#Output_Busy := TRUE;
#Output_Done := FALSE;
#Output_Error := FALSE;
#State := 1;
#Run := TRUE;
#ResetREQ_For_OPC_UA_Disconnect := TRUE;
#SetServerEndpoint := TRUE;
END_IF;
END_IF;

IF #Run = TRUE THEN


CASE #State OF
1: // case 1, connect to server
IF #SetServerEndpoint = TRUE THEN
#SetServerEndpoint := FALSE;
//set ServerSendpoint
#ServerEndpointUrl :=
WSTRING#'opc.tcp://192.168.1.1:4840';
//setting for SecurityMsgMode
//1 = None
//2 = Sign
//3 = Sign & Encrypt
#OPC_UA_SessionConnectInfo_Instance.SecurityMsgMode
:= 3;
//setting for SecurityPolicy
//1 = None
//2 = Basic128Rsa15
//3 = Basic256
//4 = Basic256Sha256

Manual, 11/2024 219


#OPC_UA_SessionConnectInfo_Instance.SecurityPolicy
:= 4;
//set TransportProfile to 1
#OPC_UA_SessionConnectInfo_Instance.TransportProfile
:= 1;
//we are using our Client-Certificate Nr. 10
//because Nr. 10 is the lastest Certificate we
created for our client application
//please look into Certificate manager for the
number of your Client certificate
//Certificate manager is located at
// "Project tree > Security settings > Security
features"
#OPC_UA_SessionConnectInfo_Instance.CertificateID :=
10;
END_IF;
IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_Connect_Instance(REQ := #Req,
ServerEndpointUrl := #ServerEndpointUrl,
SessionConnectInfo :=
#OPC_UA_SessionConnectInfo_Instance,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status,
ConnectionHdl => #ConnectionHdl);
IF #Done = TRUE THEN
#State := #State + 1;
#ResetREQ_For_OPC_UA_Disconnect := TRUE;
END_IF;
IF #Error = TRUE THEN
// Did we get a connection handle?
IF #ConnectionHdl <> 0 THEN

220 Manual, 11/2024


// We have to release all resources in the
server and disconnect
#State := 100;
ELSE
#State := 99;
END_IF;
#Mem_Status := #Status;
#OPC_UA_Connect_Instance(REQ := FALSE,
ServerEndpointUrl := #ServerEndpointUrl,
SessionConnectInfo :=
#OPC_UA_SessionConnectInfo_Instance);
#ResetREQ_For_OPC_UA_Disconnect := TRUE;
END_IF;

2: // case 2, analyse connection


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_ConnectionGetStatus_Instance(REQ := #Req,
ConnectionHdl := #ConnectionHdl,
ConnectionStatus => #ConnectionStatus,
ServerState => #ServerState,
ServiceLevel => #ServiceLevel,
Timeout := T#6S,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
#State := #State + 1;
END_IF;
IF #Error = TRUE THEN
#State := 100;
#Mem_Status := #Status;

Manual, 11/2024 221


#OPC_UA_ConnectionGetStatus_Instance(REQ :=
FALSE,
ConnectionHdl := #ConnectionHdl);
END_IF;

3: // case 3, disconnect from server


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_Disconnect_Instance(REQ := #Req,
ConnectionHdl := #ConnectionHdl,
Timeout := T#6S,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
#State := #State + 1;
END_IF;
IF #Error = TRUE THEN
#State := 100;
#Mem_Status := #Status;
#OPC_UA_Disconnect_Instance(REQ := FALSE,
ConnectionHdl := #ConnectionHdl);
END_IF;

4: //case = 4, function block has run successfully


#Output_Done := TRUE;
#Output_Busy := FALSE;
#State := 0;
#Mem_Input_REQ := FALSE;
#Run := FALSE;
#Started := FALSE;

222 Manual, 11/2024


99: // ERROR handling
#Output_Error := TRUE;
#Output_Status := #Mem_Status;
#State := 0;
#Output_Busy := FALSE;
#Run := FALSE;
#Mem_Input_REQ := FALSE;
#Started := FALSE;

100: // ERROR handling, disconnect from server to release


resources (handles)
IF #ResetREQ_For_OPC_UA_Disconnect = TRUE THEN
#ResetREQ_For_OPC_UA_Disconnect := FALSE;
//set REQ to FALSE
#OPC_UA_Disconnect_Instance(REQ := FALSE,
ConnectionHdl := #ConnectionHdl);
END_IF;
IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_Disconnect_Instance(REQ := #Req,
ConnectionHdl := #ConnectionHdl,
Timeout := T#6S,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
#Output_Error := TRUE;
#Output_Status := #Mem_Status;
#State := 0;
#Output_Busy := FALSE;
#Run := FALSE;
#Mem_Input_REQ := FALSE;

Manual, 11/2024 223


#Started := FALSE;
END_IF;
IF #Error = TRUE THEN
#Output_Error_Message := WString#'Error
handling: Resources cannot be released!';
#Output_Error := TRUE;
#Output_Status := #Mem_Status;
#State := 0;
#Output_Busy := FALSE;
#Run := FALSE;
#Mem_Input_REQ := FALSE;
#Started := FALSE;
END_IF;
END_CASE;
END_IF;

1.1.1.10.3 Program example for reading PLC tags (S7-1500)

Example program for reading PLC tags


This section includes the complete program code for the example program
"ReadFromProductionline".
The example shows you how a user program reads the values of PLC tags.
Program structure
The program operates as OPC UA client and comprises the following steps:

1. Establishing a connection to the OPC UA server of the CPU from which the values are to be
read.

2. Reading the values.

3. Terminating the connection to the OPC UA server.

You start the program with a positive edge at "Input_REQ".

Requirements
The example program assumes that you have configured a client interface called
"Productionline" and that the following data blocks are available:

Productionline_Configuration

Productionline_Data

224 Manual, 11/2024


STEP 7 (TIA Portal) generates these data blocks automatically if you have created a client
interface, see Creating client interfaces.
In addition, the example program requires that you have created and configured a connection to
the OPC UA server, see Creating and configuring connections.

Declaration
The following figure shows the declaration of local tags for the function block
"ReadFromProductionline".

Program

SCL

IF #Run = FALSE THEN


Started := #Input_REQ AND NOT #Mem_Input_REQ;
#Mem_Input_REQ := #Input_REQ;
IF #Started THEN

Manual, 11/2024 225


#Output_Busy := TRUE;
#Output_Done := FALSE;
#Output_Error := FALSE;
#Output_Status := 0;
#State := 1;
#Run := TRUE;
#Set_REQ_To_FALSE := TRUE;
//In case 100, to set REQ of instruction "OPC_UA_Disconnect"
to FALSE
END_IF;
END_IF;

IF #Run = TRUE THEN


CASE #State OF
1: // case 1, connect to server
IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_Connect_Instance(REQ := #Req,
ServerEndpointUrl :=
"Productionline_Configuration".Connection.ServerEndpointUrl,
SessionConnectInfo :=
"Productionline_Configuration".Connection.ConnectInfo,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status,
ConnectionHdl =>
"Productionline_Configuration".Connection.ConnectionHdl);
IF #Done = TRUE THEN
#State := #State + 1;
END_IF;
IF #Error = TRUE THEN

226 Manual, 11/2024


// Did we get a connection handle?
IF "Productionline_Configuration".Connection.ConnectionHdl
<> 0 THEN
// We have to release all resources in the server and
disconnect
#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconnect"
to FALSE
#Set_REQ_To_FALSE := TRUE;
ELSE
#State := 99;
END_IF;
#Mem_Status := #Status;
// set parameter REQ of OPC_UA_Connect to FALSE
#OPC_UA_Connect_Instance(REQ := FALSE,
ServerEndpointUrl :=
"Productionline_Configuration".Connection.ServerEndpointUrl,
SessionConnectInfo :=
"Productionline_Configuration".Connection.ConnectInfo,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
ConnectionHdl =>
"Productionline_Configuration".Connection.ConnectionHdl);
END_IF;

2: // case 2, get index for namespace


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_NamespaceGetIndexList_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NamespaceUrisCount :=
"Productionline_Configuration".Namespaces.NamespaceCount,
NamespaceUris :=
"Productionline_Configuration".Namespaces.NamespaceURIs,

Manual, 11/2024 227


Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
StatusList :=
"Productionline_Configuration".Namespaces.NamespaceStatusList,
NamespaceIndexes :=
"Productionline_Configuration".Namespaces.ServerNamespaceIndexes,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
IF
"Productionline_Configuration".Namespaces.NamespaceStatusList[0] = 0
THEN
#State := #State + 1;
ELSE
#State := 100;
#Mem_Status := #Status;
#Output_Error_Message := WString#'Error at
NamespaceGetIndexList';
END_IF;
END_IF;
IF #Error = TRUE THEN
#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconnect"
to FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#OPC_UA_NamespaceGetIndexList_Instance(REQ := FALSE,
NamespaceUris :=
"Productionline_Configuration".Namespaces.NamespaceURIs,
StatusList :=
"Productionline_Configuration".Namespaces.NamespaceStatusList,
NamespaceIndexes :=
"Productionline_Configuration".Namespaces.ServerNamespaceIndexes);
END_IF;

3: // case 3, get handles for nodes


IF #Busy = FALSE THEN

228 Manual, 11/2024


#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_NodeGetHandleList_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeIDCount :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeCount,
NodeIDs :=
"Productionline_Configuration".ReadLists."ReadListProduct".Nodes,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NamespaceIndexCount :=
"Productionline_Configuration".Namespaces.NamespaceCount,
NamespaceIndexes :=
"Productionline_Configuration".Namespaces.ServerNamespaceIndexes,
NodeStatusList :=
"Productionline_Data"."ReadListProduct".NodeStatusList,
NodeHdls :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeHdls,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
IF "Productionline_Data"."ReadListProduct".NodeStatusList[0]
= 0 AND
"Productionline_Data"."ReadListProduct".NodeStatusList[1] = 0
THEN
#State := #State + 1;
ELSE
#State := 100;
#Mem_Status := #Status;
#Output_Error_Message := WString#'Error at
NodeGetHandleList';
END_IF;
END_IF;
IF #Error = TRUE THEN

Manual, 11/2024 229


#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconnect"
to FALSE
#Set_REQ_To_FALSE := TRUE;
#OPC_UA_NodeGetHandleList_Instance(REQ := FALSE,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeIDCount :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeCount,
NodeIDs :=
"Productionline_Configuration".ReadLists."ReadListProduct".Nodes,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NamespaceIndexCount :=
"Productionline_Configuration".Namespaces.NamespaceCount,
NamespaceIndexes :=
"Productionline_Configuration".Namespaces.ServerNamespaceIndexes,
NodeStatusList :=
"Productionline_Data"."ReadListProduct".NodeStatusList,
NodeHdls :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeHdls);
END_IF;

4: // case 4, read from nodes


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_ReadList_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeHdlCount :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeCount,
NodeHdls :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeHdls,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NodeStatusList :=
"Productionline_Data"."ReadListProduct".NodeStatusList,

230 Manual, 11/2024


TimeStamps :=
"Productionline_Data"."ReadListProduct".TimeStamps,
Variable := "Productionline_Data"."ReadListProduct".Var
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
FOR #i := 0 TO
UINT_TO_INT("Productionline_Configuration".ReadLists."ReadListProduct".N
- 1 DO
IF NOT
("Productionline_Data"."ReadListProduct".NodeStatusList[#i] = 0) THEN
#Output_Error_Message := CONCAT_WSTRING(IN1 := WSTRING#
Readlist "ReadListProduct",
Index: ',IN2 := INT_TO_WSTRING(#i));
END_IF;
END_FOR;
#State := #State + 1;
END_IF;
IF #Error = TRUE THEN
#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconnect" to
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#OPC_UA_ReadList_Instance(REQ := FALSE,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeHdlCount :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeCount,
NodeHdls :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeHdls,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NodeStatusList :=
"Productionline_Data"."ReadListProduct".NodeStatusList,
TimeStamps :=
"Productionline_Data"."ReadListProduct".TimeStamps,
Variable := "Productionline_Data"."ReadListProduct".Var

Manual, 11/2024 231


END_IF;

5: // case 5, release node handles


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_NodeReleaseHandleList_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeHdlCount :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeCount,
NodeHdls :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeHdls,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NodeStatusList :=
"Productionline_Data"."ReadListProduct".NodeStatusList,
Done => #Done,
Error => #Error,
Busy => #Busy,
Status => #Status);
IF #Done = TRUE THEN
IF "Productionline_Data"."ReadListProduct".NodeStatusList[0]
= 0 AND
"Productionline_Data"."ReadListProduct".NodeStatusList[1] =
0
THEN
#State := #State + 1;
ELSE
#State := 100;
//In case 100, to set REQ of instruction
"OPC_UA_Disconnect" to FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#Output_Error_Message := WString#'Error at
NodeReleaseHandleList';

232 Manual, 11/2024


END_IF;
IF #Error = TRUE THEN
#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconnect"
to FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#OPC_UA_NodeReleaseHandleList_Instance(REQ := FALSE,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeHdlCount :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeCount,
NodeHdls :=
"Productionline_Configuration".ReadLists."ReadListProduct".NodeHdls,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NodeStatusList :=
"Productionline_Data"."ReadListProduct".NodeStatusList);
END_IF;

6: // case 6, disconnect from server


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_Disconnect_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
#State := #State + 1;
END_IF;

Manual, 11/2024 233


IF #Error = TRUE THEN
#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconnect"
to FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
END_IF;

7: //case = 7, function block has run successfully


#Output_Done := TRUE;
#Output_Busy := FALSE;
#State := 0;
#Mem_Input_REQ := FALSE;
#Run := FALSE;
#Started := FALSE;

99: // ERROR handling


#Output_Error := TRUE;
#Output_Status := #Mem_Status;
#State := 0;
#Output_Busy := FALSE;
#Run := FALSE;
#Mem_Input_REQ := FALSE;
#Started := FALSE;

100: // ERROR handling, disconnect from server to release


resources (handles)
IF #Set_REQ_To_FALSE = TRUE THEN
#Set_REQ_To_FALSE := FALSE;
//set REQ to FALSE
#OPC_UA_Disconnect_Instance(REQ := FALSE,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout);
END_IF;
IF #Busy = FALSE THEN

234 Manual, 11/2024


#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_Disconnect_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
#Output_Error := TRUE;
#Output_Status := #Mem_Status;
#State := 0;
#Output_Busy := FALSE;
#Run := FALSE;
#Mem_Input_REQ := FALSE;
#Started := FALSE;
END_IF;
IF #Error = TRUE THEN
#Output_Error_Message := WString#'Error handling: Resources
cannot be released!';
#Output_Error := TRUE;
#Output_Status := #Mem_Status;
#State := 0;
#Output_Busy := FALSE;
#Run := FALSE;
#Mem_Input_REQ := FALSE;
#Started := FALSE;
END_IF;
END_CASE;
END_IF;

Manual, 11/2024 235


1.1.1.10.4 Example program for writing PLC tags (S7-1500)

Example program for writing PLC tags


This section includes the complete program code for the example program
"WriteToProductionline".
The example shows you how a user program writes the values of PLC tags.
Program structure
The program operates as OPC UA client and comprises the following steps:

1. Establishing a connection to the OPC UA server of the CPU to which the values are to be

written.

2. Writing the values

3. Terminating the connection to the OPC UA server

You start the program with a positive edge at "Input_REQ".

Declaration
The following figure shows the declaration of local tags for the function block
"WriteToProductionline".

236 Manual, 11/2024


The example program also uses the following data blocks:

Productionline_Configuration

Productionline_Data

These data blocks are automatically created by STEP 7 (TIA Portal) because the example program
uses the parameter assignment for OPC UA.

Program

SCL

IF #Run = FALSE THEN


#Started := #Input_REQ AND NOT #Mem_Input_REQ;
#Mem_Input_REQ := #Input_REQ;
IF #Started THEN
#Output_Busy := TRUE;

Manual, 11/2024 237


#Output_Done := FALSE;
#Output_Error := FALSE;
#Output_Status := 0;
#State := 1;
#Run := TRUE;
#Set_REQ_To_FALSE := TRUE; //In case 100, to set REQ of
instruction "OPC_UA_Disconnect" to FALSE
END_IF;
END_IF;

IF #Run = TRUE THEN


CASE #State OF
1: // case 1, connect to server
IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_Connect_Instance(REQ := #Req,
ServerEndpointUrl :=
"Productionline_Configuration".Connection.ServerEndpointUrl,
SessionConnectInfo :=
"Productionline_Configuration".Connection.ConnectInfo,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status,
ConnectionHdl =>
"Productionline_Configuration".Connection.ConnectionHdl);
IF #Done = TRUE THEN
#State := #State + 1;
END_IF;
IF #Error = TRUE THEN
// Did we get a connection handle?

238 Manual, 11/2024


IF "Productionline_Configuration".Connection.ConnectionHdl
<> 0 THEN
// We have to release all resources in the server and
disconnect
#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconnect"
to FALSE
#Set_REQ_To_FALSE := TRUE;
ELSE
#State := 99;
END_IF;
#Mem_Status := #Status;
#OPC_UA_Connect_Instance(REQ := FALSE,
ServerEndpointUrl :=
"Productionline_Configuration".Connection.ServerEndpointUrl,
SessionConnectInfo :=
"Productionline_Configuration".Connection.ConnectInfo,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
ConnectionHdl =>
"Productionline_Configuration".Connection.ConnectionHdl);
END_IF;
2: // case 2, get index for namespace
IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_NamespaceGetIndexList_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NamespaceUrisCount :=
"Productionline_Configuration".Namespaces.NamespaceCount,
NamespaceUris :=
"Productionline_Configuration".Namespaces.NamespaceURIs,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
StatusList :=
"Productionline_Configuration".Namespaces.NamespaceStatusList,

Manual, 11/2024 239


NamespaceIndexes :=
"Productionline_Configuration".Namespaces.ServerNamespaceIndexes,
Done => #Done,
Busy => #Busy,
Error => #Error);
IF #Done = TRUE THEN
IF
"Productionline_Configuration".Namespaces.NamespaceStatusList[0] = 0
THEN
#State := #State + 1;
ELSE
#State := 100;
#Mem_Status := #Status;
#Output_Error_Message := WString#'Error at
NamespaceGetIndexList';
END_IF;
END_IF;
IF #Error = TRUE THEN
#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconnect"
to FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#OPC_UA_NamespaceGetIndexList_Instance(REQ := FALSE,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NamespaceUrisCount :=
"Productionline_Configuration".Namespaces.NamespaceCount,
NamespaceUris :=
"Productionline_Configuration".Namespaces.NamespaceURIs,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
StatusList :=
"Productionline_Configuration".Namespaces.NamespaceStatusList,
NamespaceIndexes :=
"Productionline_Configuration".Namespaces.ServerNamespaceIndexes);
END_IF;

3: // case 3, get handles for nodes

240 Manual, 11/2024


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_NodeGetHandleList_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeIDCount :=
"Productionline_Configuration".WriteLists."WriteListStatus".NodeCount,
NodeIDs :=
"Productionline_Configuration".WriteLists."WriteListStatus".Nodes,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NamespaceIndexCount :=
"Productionline_Configuration".Namespaces.NamespaceCount,
NamespaceIndexes :=
"Productionline_Configuration".Namespaces.ServerNamespaceIndexes,
NodeStatusList :=
"Productionline_Data"."WriteListStatus".NodeStatusList,
NodeHdls :=
"Productionline_Configuration".WriteLists."WriteListStatus".NodeHdls,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status =>#Status);
IF #Done = TRUE THEN
IF "Productionline_Data"."WriteListStatus".NodeStatusList[0]
= 0
THEN
#State := #State + 1;
ELSE
#State := 100;
#Mem_Status := #Status;
#Output_Error_Message := WString#'Error at
NodeGetHandleList';
END_IF;
END_IF;
IF #Error = TRUE THEN

Manual, 11/2024 241


#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconnect" to
FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#OPC_UA_NodeGetHandleList_Instance(REQ := FALSE,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeIDCount :=
"Productionline_Configuration".WriteLists."WriteListStatus".NodeCount,
NodeIDs :=
"Productionline_Configuration".WriteLists."WriteListStatus".Nodes,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NamespaceIndexCount :=
"Productionline_Configuration".Namespaces.NamespaceCount,
NamespaceIndexes :=
"Productionline_Configuration".Namespaces.ServerNamespaceIndexes,
NodeStatusList :=
"Productionline_Data"."WriteListStatus".NodeStatusList,
NodeHdls :=
"Productionline_Configuration".WriteLists."WriteListStatus".NodeHdls);
END_IF;

4: // case 4; write value to PLC variable "ProductionEnabled"


IF #SetProductionEnabled = TRUE THEN
#SetProductionEnabled := FALSE;
//set new value to true
"Productionline_Data"."WriteListStatus".Variable.ProductionEnabl
:= TRUE;
END_IF;
IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_WriteList_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,

242 Manual, 11/2024


NodeHdlCount :=
"Productionline_Configuration".WriteLists."WriteListStatus".NodeCount,
NodeHdls :=
"Productionline_Configuration".WriteLists."WriteListStatus".NodeHdls,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NodeStatusList :=
"Productionline_Data"."WriteListStatus".NodeStatusList,
Variable := "Productionline_Data"."WriteListStatus".Variab
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
FOR #i := 0 TO
UINT_TO_INT("Productionline_Configuration".WriteLists.WriteListStatus.No
- 1 DO
IF NOT ("Productionline_Data"."WriteListStatus".NodeStatus
= 0) THEN
#Output_Error_Message := CONCAT_WSTRING(IN1 := WSTRING#'Er
Writelist "WriteListStauts", Index: ',
IN2 := INT_TO_WSTRING(#i));
END_IF;
END_FOR;
#State := #State + 1;
END_IF;
IF #Error = TRUE THEN
#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconnect" to
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#OPC_UA_WriteList_Instance(REQ := FALSE,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeHdlCount :=
"Productionline_Configuration".WriteLists."WriteListStatus".NodeCount,
NodeHdls :=
"Productionline_Configuration".WriteLists."WriteListStatus".NodeHdls,

Manual, 11/2024 243


Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NodeStatusList :=
"Productionline_Data"."WriteListStatus".NodeStatusList,
Variable :=
"Productionline_Data"."WriteListStatus".Variable);
END_IF;

5: // case 5, release node handles


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_NodeReleaseHandleList_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeHdlCount :=
"Productionline_Configuration".WriteLists."WriteListStatus".NodeCount,
NodeHdls :=
"Productionline_Configuration".WriteLists."WriteListStatus".NodeHdls,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NodeStatusList :=
"Productionline_Data"."WriteListStatus".NodeStatusList,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
IF "Productionline_Data"."WriteListStatus".NodeStatusList[0]
= 0
THEN
#State := #State + 1;
ELSE
#State := 100;
#Mem_Status := #Status;
#Output_Error_Message := WString#'Error at
NodeReleaseHandleList';

244 Manual, 11/2024


END_IF;
END_IF;
IF #Error = TRUE THEN
#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconnect"
to FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#OPC_UA_NodeReleaseHandleList_Instance(REQ := FALSE,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeHdlCount :=
"Productionline_Configuration".WriteLists."WriteListStatus".NodeCount,
NodeHdls :=
"Productionline_Configuration".WriteLists."WriteListStatus".NodeHdls,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NodeStatusList :=
"Productionline_Data"."WriteListStatus".NodeStatusList);
//In case 100, to set REQ of instruction "OPC_UA_Disconnect"
to FALSE
#Set_REQ_To_FALSE := TRUE;
END_IF;

6: // case 6, disconnect from server


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_Disconnect_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
Done => #Done,
Busy => #Busy,
Error => #Error,

Manual, 11/2024 245


Status => #Status);
IF #Done = TRUE THEN
#State := #State + 1;
END_IF;

IF #Error = TRUE THEN


#State := 100;
//In case 100, to set REQ of instruction
"OPC_UA_Disconnect" to FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
END_IF;

7: //case = 7, function block has run successfully


#Output_Done := TRUE;
#Output_Busy := FALSE;
#State := 0;
#Mem_Input_REQ := FALSE;
#Run := FALSE;
#Started := FALSE;

99: // ERROR handling


#Output_Error := TRUE;
#Output_Status := #Mem_Status;
#State := 0;
#Output_Busy := FALSE;
#Run := FALSE;
#Mem_Input_REQ := FALSE;
#Started := FALSE;

100: // ERROR handling, disconnect from server to release


resources (handles)
IF #Set_REQ_To_FALSE = TRUE THEN
#Set_REQ_To_FALSE := FALSE;
//set REQ to FALSE
#OPC_UA_Disconnect_Instance(REQ := FALSE,

246 Manual, 11/2024


ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout);
END_IF;
IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_Disconnect_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
#Output_Error := TRUE;
#Output_Status := #Mem_Status;
#State := 0;
#Output_Busy := FALSE;
#Run := FALSE;
#Mem_Input_REQ := FALSE;
#Started := FALSE;
END_IF;
IF #Error = TRUE THEN
#Output_Error_Message := WString#'Error handling: Resources
cannot be released!';
#Output_Error := TRUE;
#Output_Status := #Mem_Status;
#State := 0;
#Output_Busy := FALSE;
#Run := FALSE;
#Mem_Input_REQ := FALSE;

Manual, 11/2024 247


#Started := FALSE;
END_IF;
END_CASE;
END_IF;

1.1.1.10.5 Example program for OPC_UA_TranslatePathList (S7-1500)

Example program for the instruction "OPC_UA_TranslatePathList"


This section includes the complete program code for the example program
"Read_From_RfidReader_Door_1".
The example shows you how a user program uses the instruction "OPC_UA_TranslatePathList" to
get the NodeIds of nodes and then read the values of these nodes.
You can find a description of the "OPC_UA_TranslatePathList" instruction in section
OPC_UA_TranslatePathList: Determine current NodeIds.
Program structure
The program operates as OPC UA client and comprises the following steps:

1. Establishing a connection to the OPC UA server of the CPU from which the values are to be
read.

2. Reading the values.

3. Terminating the connection to the OPC UA server.

You start the program with a positive edge at "Input_REQ".

Declaration
The following figure shows the declaration of local tags of the function block
"Read_From_RfidReader_Door_1" that uses the instruction "OPC_UA_TanslatePathList":

248 Manual, 11/2024


"UDT_Variable" data type for the values read
The local tag "Variable" (see line 43 in the picture above) uses the data type "UDT_Variable".
To enable the example program to insert the values for "DeviceInfo" and "DeviceStatus" into the
"Variable" tag, you need to create the user-defined data type "UDT_Variable" in your TIA Portal
project.
The following figure shows the structure of the "UDT_Variable" data type:

Program
The following example shows you how to use the instruction "OPC UA-TranslatePathList":

Manual, 11/2024 249


SCL

IF #Run = FALSE THEN


#Started := #Input_REQ AND NOT #Mem_Input_REQ;
#Mem_Input_REQ := #Input_REQ;
IF #Started THEN
#Output_Busy := TRUE;
#Output_Done := FALSE;
#Output_Error := FALSE;
#Output_Status := 0;
#State := 1;
#Run := TRUE;
#FirstCall := TRUE;
#Set_REQ_To_FALSE := TRUE; //In case 100, to set REQ
of instruction "OPC_UA_Disconnect" to FALSE
END_IF;
END_IF;
IF #Run = TRUE THEN
CASE #State OF
1: // case 1, connect to server
IF #FirstCall = TRUE THEN
#FirstCall := FALSE;
//set ServerEndPointUrl of the server we want to
connect to
#SeverEndpointUrl :=
WString#'opc.tcp://192.168.1.1:4840';
//set Securtiy Message Mode
// 1 = None, 2 = Sign, 3 = Sign & Encrypt
#SessionConnectInfo.SecurityMsgMode := 1;
//set Security Policy
// 1 = None, 2 = Basic128Rsa15,, 3 = Basic256, 4 =
Basic256Sha256
#SessionConnectInfo.SecurityPolicy := 1;
//set the number of the client certificate you are
using
//in our case, this is 6
//#SessionConnectInfo.CertificateID := 6;

250 Manual, 11/2024


ELSE
#Req := FALSE;
END_IF;
#OPC_UA_Connect_Instance(REQ:=#Req,
ConnectionHdl=>#ConnectionHdl,
ServerEndpointUrl:=#SeverEndpointUrl,
SessionConnectInfo:=#SessionConnectInfo,
Timeout:=T#8S,
Done=>#Done,
Busy=>#Busy,
Error=>#Error,
Status=>#Status);
IF #Done = TRUE THEN
#State := #State + 1;
#FirstCall := TRUE;
END_IF;
IF #Error = TRUE THEN
// Did we get a connection handle?
IF #ConnectionHdl <> 0 THEN
// We got a connection handle
// We have to release all resources in the
server and disconnect
#State := 100;
//In case 100, to set REQ of instruction
"OPC_UA_Disconnect" to FALSE
#Set_REQ_To_FALSE := TRUE;
ELSE
// We did not get a connection handle
#State := 99;
END_IF;
#Mem_Status := #Status;
// set parameter REQ of OPC_UA_Connect to FALSE
#OPC_UA_Connect_Instance(REQ := FALSE,
ServerEndpointUrl := #SeverEndpointUrl,
SessionConnectInfo := #SessionConnectInfo);
#FirstCall := TRUE;

Manual, 11/2024 251


END_IF;

2: // case 2, get index of Siemens namespace


IF #FirstCall = TRUE THEN
#FirstCall := FALSE;
//set Simatic namespace
#NamespaceUris[0] :=
WString#'http://www.siemens.com/simatic-s7-opcua';
END_IF;
IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_NamespaceGetIndexList_Instance(REQ := #Req,
ConnectionHdl := #ConnectionHdl,
NamespaceUrisCount := 1,
NamespaceUris := #NamespaceUris,
Timeout := T#6S,
StatusList := #NamespaceStatusList,
NamespaceIndexes := #NamespaceIndexes,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
IF #NamespaceStatusList[0] = 0 THEN //one
namespace
#State := #State + 1;
ELSE
#State := 100;
#Mem_Status := #Status;
#Output_Error_Message := WString#' Error at
NamespaceGetIndexList, Index 0';
END_IF;
#FirstCall := TRUE;
END_IF;

252 Manual, 11/2024


IF #Error = TRUE THEN
//In case 100, to set REQ of instruction "OPC_UA_Disconnect"
#Set_REQ_To_FALSE := TRUE;
#State := 100;
#Mem_Status := #Status;
#OPC_UA_NamespaceGetIndexList_Instance(REQ := FALSE,
NamespaceUris := #NamespaceUris,
StatusList := #NamespaceStatusList,
NamespaceIndexes := #NamespaceIndexes);
#FirstCall := TRUE;
END_IF;

3: // case 3, get NodeIds from server


IF #FirstCall = TRUE THEN
//set BrowsePath[0] for DeviceInfo
//set BrowsePath.StartingNode
#BrowsePaths[0].StartingNode.Identifier := WString#'85';
#BrowsePaths[0].StartingNode.IdentifierType := 0;
#BrowsePaths[0].StartingNode.NamespaceIndex := 0;

//set BrowsePath.RelativePath
#BrowsePaths[0].RelativePath.NoOfElements := 4;
#BrowsePaths[0].RelativePath.Elements[1].ReferenceTypeId.Iden
WString#'33';
#BrowsePaths[0].RelativePath.Elements[1].ReferenceTypeId.Iden
:= 0;
#BrowsePaths[0].RelativePath.Elements[1].ReferenceTypeId.Name
:= 0;
#BrowsePaths[0].RelativePath.Elements[1].TargetName.Name :=
WString#'productionline';
#BrowsePaths[0].RelativePath.Elements[1].TargetName.Namespace
#NamespaceIndexes[0];

#BrowsePaths[0].RelativePath.Elements[2].ReferenceTypeId.Iden
WString#'33';
#BrowsePaths[0].RelativePath.Elements[2].ReferenceTypeId.Iden
:= 0;

Manual, 11/2024 253


#BrowsePaths[0].RelativePath.Elements[2].ReferenceTypeId.Name
:= 0;
#BrowsePaths[0].RelativePath.Elements[2].TargetName.Name :=
WString#'DataBlocksGlobal';
#BrowsePaths[0].RelativePath.Elements[2].TargetName.Namespace
#NamespaceIndexes[0];

#BrowsePaths[0].RelativePath.Elements[3].ReferenceTypeId.Iden
WString#'33';
#BrowsePaths[0].RelativePath.Elements[3].ReferenceTypeId.Iden
:= 0;
#BrowsePaths[0].RelativePath.Elements[3].ReferenceTypeId.Name
:= 0;
#BrowsePaths[0].RelativePath.Elements[3].TargetName.Name :=
WString#'RfidReader_Door_1';
#BrowsePaths[0].RelativePath.Elements[3].TargetName.Namespace
#NamespaceIndexes[0];

#BrowsePaths[0].RelativePath.Elements[4].ReferenceTypeId.Iden
WString#'33';
#BrowsePaths[0].RelativePath.Elements[4].ReferenceTypeId.Iden
:= 0;
#BrowsePaths[0].RelativePath.Elements[4].ReferenceTypeId.Name
:= 0;
#BrowsePaths[0].RelativePath.Elements[4].TargetName.Name :=
WString#'DeviceInfo';
#BrowsePaths[0].RelativePath.Elements[4].TargetName.Namespace
#NamespaceIndexes[0];

//set BrowsePath[1] for DeviceStatus


//set BrowsePath.StartingNode
#BrowsePaths[1].StartingNode.Identifier := WString#'85';
#BrowsePaths[1].StartingNode.IdentifierType := 0;
#BrowsePaths[1].StartingNode.NamespaceIndex := 0;

//set BrowsePath.RelativePath
#BrowsePaths[1].RelativePath.NoOfElements := 4;
#BrowsePaths[1].RelativePath.Elements[1].ReferenceTypeId.Iden
WString#'33';

254 Manual, 11/2024


#BrowsePaths[1].RelativePath.Elements[1].ReferenceTypeId.Iden
:= 0;
#BrowsePaths[1].RelativePath.Elements[1].ReferenceTypeId.Name
:= 0;
#BrowsePaths[1].RelativePath.Elements[1].TargetName.Name :=
WString#'productionline';
#BrowsePaths[1].RelativePath.Elements[1].TargetName.Namespace
#NamespaceIndexes[0];

#BrowsePaths[1].RelativePath.Elements[2].ReferenceTypeId.Iden
WString#'33';
#BrowsePaths[1].RelativePath.Elements[2].ReferenceTypeId.Iden
:= 0;
#BrowsePaths[1].RelativePath.Elements[2].ReferenceTypeId.Name
:= 0;
#BrowsePaths[1].RelativePath.Elements[2].TargetName.Name :=
WString#'DataBlocksGlobal';
#BrowsePaths[1].RelativePath.Elements[2].TargetName.Namespace
#NamespaceIndexes[0];

#BrowsePaths[1].RelativePath.Elements[3].ReferenceTypeId.Iden
WString#'33';
#BrowsePaths[1].RelativePath.Elements[3].ReferenceTypeId.Iden
:= 0;
#BrowsePaths[1].RelativePath.Elements[3].ReferenceTypeId.Name
:= 0;
#BrowsePaths[1].RelativePath.Elements[3].TargetName.Name :=
WString#'RfidReader_Door_1';
#BrowsePaths[1].RelativePath.Elements[3].TargetName.Namespace
#NamespaceIndexes[0];

#BrowsePaths[1].RelativePath.Elements[4].ReferenceTypeId.Iden
WString#'33';
#BrowsePaths[1].RelativePath.Elements[4].ReferenceTypeId.Iden
:= 0;
#BrowsePaths[1].RelativePath.Elements[4].ReferenceTypeId.Name
:= 0;
#BrowsePaths[1].RelativePath.Elements[4].TargetName.Name :=
WString#'DeviceStatus';
#BrowsePaths[1].RelativePath.Elements[4].TargetName.Namespace
#NamespaceIndexes[0];

Manual, 11/2024 255


END_IF;
IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_TranslatePathList_Instance(REQ := #Req,
ConnectionHdl := #ConnectionHdl,
BrowsePathsCount := 2,
BrowsePaths := #BrowsePaths,
Timeout := T#6S,
NamespaceIndexCount := 0,
TargetNodeIDs := #TagetNodeIds,
TargetStatusList := #TargetStatusList,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
IF #TargetStatusList[0] = 0 AND
#TargetStatusList[1] = 0 THEN
#State := #State + 1;
ELSE
#State := 100;
#Mem_Status := #Status;
#Output_Error_Message := WString#'Error at
TranslatePathList';
END_IF;
#FirstCall := TRUE;
END_IF;
IF #Error = TRUE THEN
//In case 100, to set REQ of instruction
"OPC_UA_Disconnect" to FALSE
#Set_REQ_To_FALSE := TRUE;
#State := 100;
#Mem_Status := #Status;
#OPC_UA_TranslatePathList_Instance(REQ := FALSE,

256 Manual, 11/2024


ConnectionHdl := #ConnectionHdl,
BrowsePaths := #BrowsePaths,
TargetNodeIDs := #TagetNodeIds,
TargetStatusList := #TargetStatusList);
#FirstCall := TRUE;
END_IF;

4: // case 4, get handles for the NodeIds we have got


in case 3
IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_NodeGetHandleList_Instance(REQ := #Req,
ConnectionHdl := #ConnectionHdl,
NodeIDCount := 2,
NodeIDs := #TagetNodeIds,
Timeout := T#6S,
NodeStatusList := #NodeStatusList,
NodeHdls := #NodeHdls,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
IF #NodeStatusList[0] = 0 AND #NodeStatusList[1] =
0
THEN
#State := #State + 1;
ELSE
//In case 100, to set REQ of instruction
"OPC_UA_Disconnect" to FALSE
#Set_REQ_To_FALSE := TRUE;
#State := 100;
#Mem_Status := #Status;

Manual, 11/2024 257


#Output_Error_Message := WString#'Error at
NodeGetHandleList';
END_IF;
END_IF;
IF #Error = TRUE THEN
//In case 100, to set REQ of instruction
"OPC_UA_Disconnect" to FALSE
#Set_REQ_To_FALSE := TRUE;
#State := 100;
#Mem_Status := #Status;
#OPC_UA_NodeGetHandleList_Instance(REQ := FALSE,
NodeIDs := #TagetNodeIds,
NodeStatusList := #NodeStatusList,
NodeHdls := #NodeHdls);
END_IF;

5: // case 5, read the values of the NodeIds


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_ReadList_Instance(REQ := #Req,
ConnectionHdl := #ConnectionHdl,
NodeHdlCount := 2,
NodeHdls := #NodeHdls,
Timeout := T#6S,
NodeStatusList := #NodeStatusList,
Variable := #Variable,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
FOR #i := 0 TO 1 DO
IF NOT (#NodeStatusList[#i] = 0) THEN

258 Manual, 11/2024


#Output_Error_Message :=
CONCAT_WSTRING(IN1 := WSTRING#'Error at Readlist, Index: ',
IN2 := INT_TO_WSTRING(#i));
END_IF;
END_FOR;
#State := #State + 1;
END_IF;
IF #Error = TRUE THEN
//In case 100, to set REQ of instruction
"OPC_UA_Disconnect" to FALSE
#Set_REQ_To_FALSE := TRUE;
#State := 100;
#Mem_Status := #Status;
#OPC_UA_ReadList_Instance(REQ := FALSE,
NodeHdls := #NodeHdls,
NodeStatusList := #NodeStatusList,
Variable := #Variable);
END_IF;

6: // case 6, release the node handles


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_NodeReleaseHandleList_Instance(REQ := #Req,
ConnectionHdl := #ConnectionHdl,
NodeHdlCount := 1,
NodeHdls := #NodeHdls,
Timeout := T#6S,
NodeStatusList := #NodeStatusList,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #NodeStatusList[0] = 0 AND #NodeStatusList[1] = 0

Manual, 11/2024 259


THEN
#State := #State + 1;
ELSE
//In case 100, to set REQ of instruction
"OPC_UA_Disconnect" to FALSE
#Set_REQ_To_FALSE := TRUE;
#State := 100;
#Mem_Status := #Status;
#Output_Error_Message := WString#'Error at
NodeReleasetHandleList';
END_IF;
IF #Error = TRUE THEN
//In case 100, to set REQ of instruction
"OPC_UA_Disconnect" to FALSE
#Set_REQ_To_FALSE := TRUE;
#State := 100;
#Mem_Status := #Status;
#OPC_UA_NodeReleaseHandleList_Instance(REQ :=
FALSE,
NodeHdls := #NodeHdls,
NodeStatusList := #NodeStatusList);
END_IF;

7: // case 7; disconnect form server


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_Disconnect_Instance(REQ := #Req,
ConnectionHdl := #ConnectionHdl,
Timeout := T#6S,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN

260 Manual, 11/2024


#State := #State + 1;
END_IF;
IF #Error = TRUE THEN
//In case 100, to set REQ of instruction
"OPC_UA_Disconnect" to FALSE
#Set_REQ_To_FALSE := TRUE;
#State := 100;
#Mem_Status := #Status;
#OPC_UA_Disconnect_Instance(REQ := FALSE,
ConnectionHdl := #ConnectionHdl);
END_IF;

8: //case = 8, function block has run successfully


#Output_Done := TRUE;
#Output_Busy := FALSE;
#State := 0;
#Mem_Input_REQ := FALSE;
#Run := FALSE;
#Started := FALSE;

99: // ERROR handling


#Output_Error := TRUE;
#Output_Status := #Mem_Status;
#State := 0;
#Output_Busy := FALSE;
#Run := FALSE;
#Mem_Input_REQ := FALSE;
#Started := FALSE;

100: // ERROR handling, disconnect from server to


release resources (handles)
IF #Set_REQ_To_FALSE = TRUE THEN
#Set_REQ_To_FALSE := FALSE;
//set REQ to FALSE
#OPC_UA_Disconnect_Instance(REQ := FALSE,
ConnectionHdl := #ConnectionHdl);

Manual, 11/2024 261


END_IF;
IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_Disconnect_Instance(REQ := #Req,
ConnectionHdl := #ConnectionHdl,
Timeout := T#6S,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
#Output_Error := TRUE;
#Output_Status := #Mem_Status;
#State := 0;
#Output_Busy := FALSE;
#Run := FALSE;
#Mem_Input_REQ := FALSE;
#Started := FALSE;
END_IF;
IF #Error = TRUE THEN
#Output_Error_Message := WString#'Error handling:
Resources cannot be released!';
#Output_Error := TRUE;
#Output_Status := #Mem_Status;
#State := 0;
#Output_Busy := FALSE;
#Run := FALSE;
#Mem_Input_REQ := FALSE;
#Started := FALSE;
END_IF;
END_CASE;
END_IF;

262 Manual, 11/2024


1.1.1.10.6 Example program for calling a method of an OPC UA server (S7-1500)

Example program for calling a server method


This section includes the complete program code for the example program
"Call_OpenDoor_On_Productionline".
The example shows you how a user program uses the instruction "OPC_UA_MethodCall" to call a
server method.
You can find a description of the "OPC_UA_MethodCall" instruction in section
OPC_UA_MethodCall: Call method.
Program structure
The program operates as OPC UA client and comprises the following steps:

1. Establishing a connection to an OPC UA server.

2. Calling the server method.

3. Terminating the connection to the OPC UA server.

You start the program with a positive edge at "Input_REQ".

Declaration
The following figure shows the declaration of local tags for the function block
"Call_OpenDoor_On_Productionline".

Manual, 11/2024 263


Program

SCL

IF #Run = FALSE THEN


#Started := #Input_REQ AND NOT #Mem_Input_REQ;
#Mem_Input_REQ := #Input_REQ;
IF #Started THEN
#Output_Busy := TRUE;
#Output_Done := FALSE;
#Output_Error := FALSE;
#Output_Status := 0;
#Output_Error_Message := WSTRING#'';
#State := 1;

264 Manual, 11/2024


#Run := TRUE;
#Init_Method_InputParameter := TRUE;
#Set_REQ_To_FALSE := TRUE;
END_IF;
END_IF;
IF #Run = TRUE THEN
CASE #State OF
1: // case 1, connect to server
IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_Connect_Instance(REQ := #Req,
ServerEndpointUrl :=
"Productionline_Configuration".Connection.ServerEndpointUrl,
SessionConnectInfo :=
"Productionline_Configuration".Connection.ConnectInfo,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status,
ConnectionHdl =>
"Productionline_Configuration".Connection.ConnectionHdl);
IF #Done = TRUE THEN
#State := #State + 1;
END_IF;
IF #Error = TRUE THEN
// Did we get a connection handle?
IF
"Productionline_Configuration".Connection.ConnectionHdl <> 0 THEN
// We have to release all resources in the server and
disconnect
#State := 100;
//In case 100, to set REQ of instruction
"OPC_UA_Disconnect" to FALSE

Manual, 11/2024 265


#Set_REQ_To_FALSE := TRUE;
ELSE
#State := 99;
END_IF;
#Mem_Status := #Status;
#OPC_UA_Connect_Instance(REQ := FALSE,
ServerEndpointUrl :=
"Productionline_Configuration".Connection.ServerEndpointUrl,
SessionConnectInfo :=
"Productionline_Configuration".Connection.ConnectInfo,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
ConnectionHdl =>
"Productionline_Configuration".Connection.ConnectionHdl);
END_IF;

2: // case 2, get index of Siemens namespace


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_NamespaceGetIndexList_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NamespaceUrisCount :=
"Productionline_Configuration".Namespaces.NamespaceCount,
NamespaceUris :=
"Productionline_Configuration".Namespaces.NamespaceURIs,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
StatusList :=
"Productionline_Configuration".Namespaces.NamespaceStatusList,
NamespaceIndexes :=
"Productionline_Configuration".Namespaces.ServerNamespaceIndexes,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);

266 Manual, 11/2024


IF #Done = TRUE THEN
IF
"Productionline_Configuration".Namespaces.NamespaceStatusList[0] = 0
THEN //one namespace
#State := #State + 1;
ELSE
#State := 100;
//In case 100, to set REQ of instruction
"OPC_UA_Disconnect" to FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#Output_Error_Message := WString#' Error at
NamespaceGetIndexList, Index 0';
END_IF;
END_IF;
IF #Error = TRUE THEN
#State := 100;
//In case 100, to set REQ of instruction
"OPC_UA_Disconnect" to FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#OPC_UA_NamespaceGetIndexList_Instance(REQ := FALSE,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NamespaceUrisCount :=
"Productionline_Configuration".Namespaces.NamespaceCount,
NamespaceUris :=
"Productionline_Configuration".Namespaces.NamespaceURIs,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
StatusList :=
"Productionline_Configuration".Namespaces.NamespaceStatusList,
NamespaceIndexes :=
"Productionline_Configuration".Namespaces.ServerNamespaceIndexes);
END_IF;

3: // case 3, get an handle for server method OpenDoor


IF #Busy = FALSE THEN
#Req := TRUE;

Manual, 11/2024 267


ELSE
#Req := FALSE;
END_IF;
#OPC_UA_MethodGetHandleList_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeIDCount :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodCo
ObjectNodeIDs :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".ObjectNo
MethodNodeIDs :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodNo
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NamespaceIndexCount :=
"Productionline_Configuration".Namespaces.NamespaceCount,
NamespaceIndexes :=
"Productionline_Configuration".Namespaces.ServerNamespaceIndexes,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status,
StatusList :=
"Productionline_Data"."MethodListOpenDoor".MethodStatusList,
MethodHdls :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodHd
IF #Done = TRUE THEN
IF "Productionline_Data"."MethodListOpenDoor".MethodStatusLis
= 0 THEN //one method
#State := #State + 1;
ELSE
#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconne
to FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#Output_Error_Message := WString#'Error at
MethodGetHandleList';
END_IF;

268 Manual, 11/2024


END_IF;
IF #Error = TRUE THEN
#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconnect"
FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#OPC_UA_MethodGetHandleList_Instance(REQ := FALSE,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
NodeIDCount :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodCo
ObjectNodeIDs :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".ObjectNo
MethodNodeIDs :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodNo
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
NamespaceIndexCount :=
"Productionline_Configuration".Namespaces.NamespaceCount,
NamespaceIndexes :=
"Productionline_Configuration".Namespaces.ServerNamespaceIndexes,
StatusList :=
"Productionline_Data"."MethodListOpenDoor".MethodStatusList,
MethodHdls :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodHd
END_IF;

4: // case 4, call method OpenDoor


IF #Init_Method_InputParameter = TRUE THEN
#Init_Method_InputParameter := FALSE;
// for our server method at Productionline, we set input
parameters to 1
"Productionline_Data".MethodListOpenDoor.Method.Inputs.Number
1;
END_IF;
IF #Busy = FALSE THEN
#Req := TRUE;
ELSE

Manual, 11/2024 269


#Req := FALSE;
END_IF;
OPC_UA_MethodCall_Instance(REQ := #Req,
ConnectionHdl:="Productionline_Configuration".Connection
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
MethodHdl :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodHd
InputArguments :=
"Productionline_Data"."MethodListOpenDoor"."Method".Inputs,
OutputArguments :=
"Productionline_Data"."MethodListOpenDoor"."Method".Outputs,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status =>
"Productionline_Data"."MethodListOpenDoor".MethodStatusList[0],
MethodResult :=
"Productionline_Data"."MethodListOpenDoor".MethodResultList[0]);
//"Productionline_Data"."MethodListOpenDoor".MethodResultList[0]
//the status/error codes of the server method
//which was run on the connected CPU as user program
//These codes are defined as follows:
// Good: 0x0000_0000 TO 0x3FFF_ FFFF
// Uncertain: 0x4000_0000 TO 0x7FFF_FFFF
// Bad: 0x8000_0000 TO 0xFFFF_FFFF
#Output_MethodResult :=
"Productionline_Data".MethodListOpenDoor.MethodResultList[0];
IF #Done = TRUE THEN
IF #MethodResult < 16#8000_0000 THEN
#State := #State + 1;
ELSE
//server method did not run successfully
#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconne
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#Output_Error_Message := WString#' Error at server method

270 Manual, 11/2024


END_IF;
END_IF;
IF #Error = TRUE THEN
#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconnect"
#Set_REQ_To_FALSE := TRUE;
#Mem_Status :=
"Productionline_Data".MethodListOpenDoor.MethodStatusList[0];
#OPC_UA_MethodCall_Instance(REQ := #Req,
ConnectionHdl:="Productionline_Configuration".Connection
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
MethodHdl :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodHd
InputArguments :=
"Productionline_Data"."MethodListOpenDoor"."Method".Inputs,
OutputArguments :=
"Productionline_Data"."MethodListOpenDoor"."Method".Outputs,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status =>
"Productionline_Data"."MethodListOpenDoor".MethodStatusList[0],
MethodResult :=
"Productionline_Data"."MethodListOpenDoor".MethodResultList[0]);
END_IF;

5: // case 5, release method handle


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_MethodReleaseHandleList_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,

Manual, 11/2024 271


MethodHdlCount :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodCo
MethodHdls :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodHd
StatusList :=
"Productionline_Data"."MethodListOpenDoor".MethodStatusList,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
#Mem_Status := #Status;
IF "Productionline_Data"."MethodListOpenDoor".MethodStatusLis
= 0 THEN
#State := #State + 1;
ELSE
#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconne
to FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#Output_Error_Message := WString#'Error at
MethodGetHandleList';
END_IF;
END_IF;
IF #Error = TRUE THEN
#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconnect"
FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#OPC_UA_MethodReleaseHandleList_Instance(REQ := FALSE,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
MethodHdlCount :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodCo

272 Manual, 11/2024


MethodHdls :=
"Productionline_Configuration".MethodLists."MethodListOpenDoor".MethodHd
StatusList :=
"Productionline_Data"."MethodListOpenDoor".MethodStatusList);
END_IF;

6: // case 6, disconnect from server


IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_Disconnect_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
#State := #State + 1;
#Mem_Status := #Status;
END_IF;
IF #Error = TRUE THEN
#State := 100;
//In case 100, to set REQ of instruction "OPC_UA_Disconnect"
FALSE
#Set_REQ_To_FALSE := TRUE;
#Mem_Status := #Status;
#OPC_UA_Disconnect_Instance(REQ := FALSE,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout);
END_IF;

Manual, 11/2024 273


7: //case = 7, function block has run successfully
#Output_Done := TRUE;
#Output_Busy := FALSE;
#State := 0;
#Mem_Input_REQ := FALSE;
#Run := FALSE;
#Started := FALSE;

99: // ERROR handling


#Output_Error := TRUE;
#Output_Status := #Mem_Status;
#State := 0;
#Output_Busy := FALSE;
#Run := FALSE;
#Mem_Input_REQ := FALSE;
#Started := FALSE;

100: // ERROR handling, disconnect from server to release


resources (handles)
IF #Set_REQ_To_FALSE = TRUE THEN
#Set_REQ_To_FALSE := FALSE;
//set REQ to definitely to FALSE
#OPC_UA_Disconnect_Instance(REQ := FALSE,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,
Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout);
END_IF;
IF #Busy = FALSE THEN
#Req := TRUE;
ELSE
#Req := FALSE;
END_IF;
#OPC_UA_Disconnect_Instance(REQ := #Req,
ConnectionHdl :=
"Productionline_Configuration".Connection.ConnectionHdl,

274 Manual, 11/2024


Timeout :=
"Productionline_Configuration".Connection.ConnectInfo.SessionTimeout,
Done => #Done,
Busy => #Busy,
Error => #Error,
Status => #Status);
IF #Done = TRUE THEN
#Output_Error := TRUE;
#Output_Status := #Mem_Status;
#State := 0;
#Output_Busy := FALSE;
#Run := FALSE;
#Mem_Input_REQ := FALSE;
#Started := FALSE;
END_IF;
IF #Error = TRUE THEN
#Output_Error_Message := WString#'Error handling:
Resources cannot be released!';
#Output_Error := TRUE;
#Output_Status := #Mem_Status;
#State := 0;
#Output_Busy := FALSE;
#Run := FALSE;
#Mem_Input_REQ := FALSE;
#Started := FALSE;
END_IF;
END_CASE;
END_IF;

1.1.2 Server instructions (S7-1200, S7-1500)

1.1.2.1 Methods (S7-1200, S7-1500)

1.1.2.1.1 OPC_UA_ServerMethodPre: Preparing the server method call (S7-1200, S7-1500)

Validity
The following description of the "OPC_UA_ServerMethodPre" instruction applies to S7-1200-
CPUs firmware version V4.5 and higher and for S7-1500-CPUs firmware version V2.5 and higher.

Manual, 11/2024 275


New instruction version V1.1 from firmware version V3.1
As of firmware version V3.1, the new instruction version V1.1 is supported. You can find
information on compatibility in the Instructions for using server methods section.

Description
This section describes the instruction "OPC_UA_ServerMethodPre".
Because the instructions "OPC_UA_ServerMethodPre" and "OPC_UA_ServerMethodPost" always
have to be called up in pairs in the user program, please also take into account the section on
the instruction "OPC_UA_ServerMethodPost".

Parameters for "OPC_UA_ServerMethodPre"


The parameters of the instruction "OPC_UA_ServerMethodPre"

Parameter Declaration Data type Meaning

Done Output BOOL Status of execution:

0: Execution of the

instruction aborted, not yet

complete or not yet started

1: Execution of instruction

completed without errors

Busy Output BOOL Execution status parameter:

0: Instruction not being


executed

1: Instruction currently
being executed

Error Output BOOL Error display

0: No error

1: An error has occurred.

See "Status" parameter.

Status Output DWORD Cause of the error, see "Error


codes for the status" below.

276 Manual, 11/2024


UAMethodCalled Output BOOL The method provided has been called
by an OPC UA client.

UAMethod_InParameters InOut VARIANT Pointer to a tag that contains the


input parameters for the method
provided.

Error codes for the status


The "Status" parameter provides information about errors that occurred during execution of the
instruction.
The following table describes the different categories of error codes.
Error codes for the status

Error code Explanation


(hexadecimal values)

0000_0000 Instruction finished successfully.

8xxx_xxxx OPC UA specific error

Axxx_xxxx PLCopen specific error

B080_C300 Insufficient resources

B08x_yz00 SIMATIC-specific error

e.g. B080_B000 TooManyMethods:


Maximum number of server methods or max. number of
server method instances exceeded.
(Calling the instructions OPC_UA_ServerMethodPre,
OPC_UA_ServerMethodPost):
Example for S7-1510 to S7-1513 ...: Max. 20 (FW V3.0)
Example for S7-1515, S7-1516...: Max. 50 (FW V3.0)
Example for S7-1517, S7-1518, S7-1507S...: Max. 100 (FW
V3.0)
Refer to the technical specifications of the CPUs (number of
server methods, max.)

For more error codes, see Error codes

Number of server methods


The number of methods that can be registered is limited depending on the CPU. When these
limits are violated, calling this instruction results in the "TooManyMethods" error code specified
above.

Manual, 11/2024 277


Violation of the configuration limit is also indicated by the fact that the instances of the methods
are displayed in the address space of the OPC UA server but shown as not callable.
The following figure shows the representation of the methods in the UaExpert in the "good case"
and in the case of exceeded quantity structures.

Declaration of tags
Declare an instance of the instruction "OPC_UA_ServerMethodPre" and the tags with which you
supply the instruction parameters, see also Example program for providing a method for OPC UA
clients.
The following points are important for the declaration:

Create the instruction "OPC_UA_ServerMethodPre" as a multi-instance in the calling function

block.

Note

Name of the multiple instance

The multiple instance has to be named "OPC_UA_ServerMethodPre_Instance",


otherwise no method is created on the server.

Use drag-and-drop to move the instruction from the folder "Instructions > Communication

> OPC UA > OPC UA Server" to the editor.

Next, click "Multi-instance".

When the server method has one or more input parameters, you must declare a tag with the
name "UAMethod_InParameters".

First, create a PLC data type (UDT) for the input parameters of the server method.

Then use this UDT for the tag "UAMethod_InParameters".

In the example, the data type is called "UDT_OpenDoorInArguments" and includes the

element Number.

Alternative:

You can also assign the data type "Struct" to the tag "UAMethod_InParameters". Then
create the components of this data type according to the input parameters of the server

method (same names and data types).

278 Manual, 11/2024


Calling the instruction
The instruction "OPC_UA_ServerMethodPre" queries the operating system to determine whether
or not the server method was called.
If the server method was called by the client, the instruction "OPC_UA_ServerMethodPre"
provides the input parameters for the server method.

Assignment of data types (SIMATIC – OPC UA)


For the input and output parameters of methods, note the explanations on the rules for usable
data types (S7-1500: Boundary conditions for using server methods, S7-1200: Boundary
conditions for using server methods).

Note
Supply of structured data types with nested arrays
If a structured data type (Struct/UDT) contains an array, the OPC UA server does not
provide information about the length of this array.
If you use such a structure as the input or output parameter of a server method, for
example, you must ensure that the nested array is supplied with the correct length
when the method is called.
If you do not adhere to this rule, the method fails with the error code
"BadInvalidArgument".

1.1.2.1.2 OPC_UA_ServerMethodPost: Post preparation of the server method call (S7-1200, S7-1500)

Validity
The following description of the "OPC_UA_ServerMethodPost" instruction applies to S7-1200-
CPUs firmware version V4.5 and higher and for S7-1500-CPUs firmware version V2.5 and higher.

New instruction version V1.1 from firmware version V3.1


As of firmware version V3.1, the new instruction version V1.1 is supported. You can find
information on compatibility in the Instructions for using server methods section.

Manual, 11/2024 279


Description
This section describes the instruction "OPC_UA_ServerMethodPost".
Because the instructions "OPC_UA_ServerMethodPre" and "OPC_UA_ServerMethodPost" always
have to be called up in pairs in the user program, please also take into account the section on
the instruction "OPC_UA_ServerMethodPre".

Parameters for "OPC_UA_ServerMethodPost"


The parameters of the instruction "OPC_UA_ServerMethodPost"

Parameter Declaration Data type Meaning

Done Output BOOL Status of execution:

0: Execution of the
instruction aborted, not yet

complete or not yet started

1: Execution of instruction

completed without errors

Busy Output BOOL Execution status parameter:

0: Instruction not being

executed

1: Instruction currently

being executed

Error Output BOOL Error display

0: No error

1: An error has occurred.

See "Status" parameter.

Status Output DWORD Cause of the error, see "Error


codes for the status" below.

280 Manual, 11/2024


Good: 0x0000_0000 to 0x3FFF_
FFFF

Uncertain: 0x4000_0000 to
0x7FFF_FFFF

Bad: 0x8000_0000 to 0xFFFF_FFFF

Depending on the client it is possible


that the codes of the areas "Good"
and "Uncertain" are not output.

UAMethod_Finished Input BOOL Set the value of the parameter to


TRUE if the method provided has been
executed.

UAMethod_OutParameters InOut VARIANT Pointer to a tag that contains the


output parameters of the method
provided.

Error codes for the status


The "Status" parameter provides information about errors that occurred during execution of the
instruction.
The following table describes the different categories of error codes.
Error codes for the status

Error code Explanation


(hexadecimal values)

0000_0000 Instruction finished successfully.

8xxx_xxxx OPC UA specific error

Axxx_xxxx PLCopen specific error

B080_C300 Insufficient resources

B08x_yz00 SIMATIC-specific error

For more error codes, see Error codes

Declaration of tags
Declare an instance of the instruction "OPC_UA_ServerMethodPost" and the tags with which you
supply the instruction parameters, see also Example program for providing a method for OPC UA
clients.

Manual, 11/2024 281


The following points are important for the declaration:

Create the instruction "OPC_UA_ServerMethodPost" as a multi-instance in the calling

function block.

Note

Name of the multiple instance

The multiple instance has to be named "OPC_UA_ServerMethodPost_Instance",


otherwise no method is created on the server.

Use drag-and-drop to move the instruction from the folder "Instructions > Communication

> OPC UA > OPC UA Server" to the editor. Next, click "Multi-instance".

When the server method has one or more output parameters, you must declare a tag with

the name "UAMethod_OutParameters".

First, create a PLC data type (UDT) for the output parameters of the server method.

Then use this UDT for the tag "UAMethod_OutParameters".

In the example, the data type is called "UDT_OpenDoorOutArguments"; the only output
parameter is Result.

Alternative:

You can also assign the data type "Struct" to the tag "UAMethod_OutParameters". Then

create the components of this data type according to the output parameters of the server
method (same names and data types).

Declaration of tags

282 Manual, 11/2024


Calling the instruction
You use the "OPC_UA_ServerMethodPost" instruction to inform the operating system that the
server method has been executed and that the values of the output parameters are valid.

Assignment of data types (SIMATIC – OPC UA)


For the input and output parameters of methods, note the explanations on the rules for usable
data types (S7-1500: Boundary conditions for using server methods, S7-1200: Boundary
conditions for using server methods).

Note
Supply of structured data types with nested arrays
If a structured data type (Struct/UDT) contains an array, the OPC UA server does not
provide information about the length of this array.
If you use such a structure as the input or output parameter of a server method, for
example, you must ensure that the nested array is supplied with the correct length
when the method is called.
If you do not adhere to this rule, the method fails with the error code
"BadInvalidArgument".

1.1.2.1.3 Instructions for using server methods (S7-1200, S7-1500)

To implement server methods in an S7-1500 CPU, use the "OPC_UA_ServerMethodPre" and


"OPC_UA_ServerMethodPost" instructions.
Details of the new version V1.1 of these two instructions are explained below.

For S7-1500R/H CPUs as of FW version V3.1, version V1.1 of the server instructions is
mandatory - the use of version V1.0 is not permitted.

The version V1.1 is also mandatory for the following S7-1500 CPUs:

- CPU 1517(F)‑3 PN

- CPU 1518(F)‑3 PN

- CPU 1516T(F)-3 PN

- CPU 1517T(F)-3 PN

- CPU 1518T(F)-3 PN

The following recommendation applies to the other S7-1500 standard CPUs: For new
projects starting from TIA Portal V19 and CPU firmware version V3.1, always use the new

server instruction version V1.1 or higher.

Within a project, you can use both the instructions with version V1.0 and the instructions

with version V1.1. You can only use one version within a CPU user program.

Manual, 11/2024 283


Compatibility between version V1.0 and V1.1 of the instructions for server
methods
There are the following differences between version V1.0 and V1.1 with regard to the server
instructions:

Resetting the output parameter "UAMethod_Called" of the server instruction

"OPC_UA_ServerMethodPre":

- V1.0: "UAMethod_Called" is automatically reset if both "DONE" of the

"OPC_UA_ServerMethodPre" instruction and "DONE" of the "OPC_UA_ServerMethodPost"

instruction are reset. "UAMethod_Called" is therefore only reset when


"OPC_UA_ServerMethodPost" is completed.

- V1.1: "UAMethod_Called" is automatically reset when output parameter "DONE" of the


"OPC_UA_ServerMethodPre" instruction is reset. "UAMethod_Called" is therefore only

available for one cycle.

Release of the instances of "OPC_UA_ServerMethodPre" and "OPC_UA_ServerMethodPost":

- V1.0: No cyclic call of the server instructions required.

- V1.1: Mandatory cyclical call of the server instructions required.

The "OPC_UA_ServerMethodPre" and "OPC_UA_ServerMethodPost" instructions in version

V1.1 behave in accordance with the description for asynchronous instructions. For

information on this, see TIA Portal information system "Asynchronous working instructions".

Note
When switching to the OPC UA server methods from version V1.0 to version V1.1,
check whether your user program takes into account the described change in
functionality. Adjust your program if necessary.

Example program
FUNCTION_BLOCK "mySERVER_METHOD"
{ S7_Optimized_Access := 'TRUE' }
VERSION : 0.1
VAR DB_SPECIFIC
UAMethod_InParameters : Struct
IN_BOOL : Bool;
IN_INT : Int;
END_STRUCT;
UAMethod_OutParameters : Struct
OUT_BOOL : Bool;
OUT_INT : Int;
END_STRUCT;

284 Manual, 11/2024


END_VAR
VAR
OPC_UA_ServerMethodPre_Instance {InstructionName :=
'OPC_UA_ServerMethodPre'; LibVersion := '1.1'} :
OPC_UA_ServerMethodPre;
DONE_PRE { S7_SetPoint := 'True'} : Bool;
BUSY_PRE : Bool;
ERROR_PRE : Bool;
STATUS_PRE : DWord;
UAMethod_Called : Bool;
OPC_UA_ServerMethodPost_Instance {InstructionName :=
'OPC_UA_ServerMethodPost'; LibVersion := '1.1'} :
OPC_UA_ServerMethodPost;
UAMethod_Result { S7_SetPoint := 'True'} : DWord;
UAMethod_Finished : Bool;
DONE_POST { S7_SetPoint := 'True'} : Bool;
BUSY_POST : Bool;
ERROR_POST : Bool;
STATUS_POST : DWord;
END_VAR

BEGIN
#OPC_UA_ServerMethodPre_Instance(Done => #DONE_PRE,
Busy => #BUSY_PRE,
Error => #ERROR_PRE,
Status => #STATUS_PRE,
UAMethod_Called => #UAMethod_Called,
UAMethod_InParameters := #UAMethod_InParameters);

//Method is called
IF #UAMethod_Called AND NOT #ERROR_PRE THEN

(* Functionality: InParameters are valid and copied to OutParameters


*)

#UAMethod_OutParameters.OUT_BOOL := #UAMethod_InParameters.IN_BOOL;

#UAMethod_OutParameters.OUT_INT := #UAMethod_InParameters.IN_INT;

(* If Method is finished without errors prepare output parameters of


OPC_UA_ServerMethodPost accordingly *)

#UAMethod_Result := 0;
#UAMethod_Finished := TRUE;
END_IF;

#OPC_UA_ServerMethodPost_Instance(UAMethod_Result := #UAMethod_Result,
UAMethod_Finished := #UAMethod_Finished,
Done => #DONE_POST,
Busy => #BUSY_POST,

Manual, 11/2024 285


Error => #ERROR_POST,
Status => #STATUS_POST,
UAMethod_OutParameters := #UAMethod_OutParameters);

(* Reset Input Parameters after OPC_UA_ServerMethodPost is done *)

IF #DONE_POST OR #ERROR_POST THEN

#UAMethod_Finished := FALSE;
#UAMethod_Result := 0;

END_IF;

END_FUNCTION_BLOCK

See also
OPC_UA_ServerMethodPre: Preparing the server method call (S7-1200, S7-1500)
OPC_UA_ServerMethodPost: Post preparation of the server method call (S7-1200, S7-1500)

1.2 Communications processor (S7-1200, S7-1500)