0% found this document useful (0 votes)
7 views1 page

F1

The document outlines the structural design details for a 3-storey residential project located in Burauen, Leyte, including material properties, column and footing specifications, and applied forces. It provides calculations for soil pressures, stability checks, shear design, and reinforcement requirements, confirming that all parameters are within safe limits. The design has been verified by Engr. Mark Christian D. Esguerra and is licensed for his use.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
7 views1 page

F1

The document outlines the structural design details for a 3-storey residential project located in Burauen, Leyte, including material properties, column and footing specifications, and applied forces. It provides calculations for soil pressures, stability checks, shear design, and reinforcement requirements, confirming that all parameters are within safe limits. The design has been verified by Engr. Mark Christian D. Esguerra and is licensed for his use.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Project : 3-STOREY RESIDENTIAL Design by :

LOGO Owner :
Location : BURAUEN LEYTE
Check by : Engr. Mark Christian D. Esguerra
Mark :
Date :
F1
5/1/2022
ISOLATED FOOTING

Material Properties Column Properties: Reinforcement Details:


Concrete f'c = 20.70 Mpa Width = 0.25 m Location #
Reinforcing fy = 414.00 Mpa Height = 0.25 m Bot Bar Dia = 16.00
Location = CenterMid Along x = 12 OK!
Soil Properties: Footing Properties: Along y = 12 OK!
σall=

0.25 m
140.00 kPa Length = 1.80 m Cover (mm) = 75.00

1.8 m
γ= 18.00 kN/m3 Width = 1.80 m
Thickness = 0.35 m 0.25 m
Depth = 1.50 m
Applied forces:
Load Case Pu Mx My Fx Fy
qa factor
Units kN kN.m kN.m kN kN
Service Load = 318.52 7.59 35.62 17.98 4.90 1.33
1.8 m
Factored Load = 414.19 8.60 49.87 22.83 3.56 1.00

Check for Soil Pressures (Service Load) Check for Stability (Service Load)
Location Total Pressure Remark Overturning Sliding
Corner 1= 182.45 kPa x-x y-y
x-x y-y
Corner 2= 163.31 kPa Overturn Resisting Overturn Resisting
Corner 3= 77.06 kPa 9.30 378.37377 41.91 378.37377 Ratio Ratio
Corner 4= 96.21 kPa 40.66506663 9.027295103 13.45 49.42
Ratio 0.98 Safe Safe Safe Safe

Check for Shear Design (Factored Load)


Check Wide Beam Shear Check Punching Shear
163.31 kPa
-Side +Side Units x-x y-y Unit
77.06 kPa Along x 0.47 0.43 Mpa Unbalance Moment factor = 0.4 0.4
Along x 0.57 0.33 Mpa Column Location Factor = 40
182.45 kPa Absolute max. Stress = 0.57 MPa ColumnAspect Ratio = 1
Under-strenght φ Factor = 0.75 Actual Punching Stress = 0.99 MPa
96.21 kPa
Allowable Shear Capacity = 0.58 MPa Allowable Shear Capacity = 1.13 Mpa
3D Zoom In Zoom Out
Ratio 0.983 Safe Ratio 0.88 Safe
Detailed Calculations
Check for Stability (Service Load) Check for Soil Pressure (Service Load) Check for Shear (Factored Load) Check for Reinforcement (Factored Load)
Overturning about x-x Soil Pressure Punching Shear Design of steel
Moment = 7.59 Overturn Mom x-x = 9.30 kN-m Net Ultimate Bottom Reinforcement
Shear Force = 1.71 Resisting Mom x-x = 378.37 kN-m soil pressure at critical point Along x Along y Unit
Total = 9.30 Overturn Mom y-y = 41.91 kN-m Point 1 = 179.02 kPa Mu = 90.12 105.48 kN.m
Resisting about x-x Resisting Mom y-y = 378.37 kN-m Point 2 = 173.28 kPa Ru = 0.829 0.971 MPa
Footing Weight = 24.49 Resisting Force = 420.42 kN Point 3 = 139.55 kPa m= 23.529 23.529
Soil Weight = 77.21 Xp = 0.80 Point 4 = 145.29 kPa req'd p = 0.00205 0.00241
Bouyancy = (10.00) Yp = 0.88 Average = 159.29 kPa min p = 0.00338 0.00338
Axial = 286.67 X-ecc = 0.10 Calculation of unbalanced moment transferred by use p = 0.00274 0.00322
Total = 378.37 Y-ecc = 0.02 eccentricity of shear As = 1,276 1,500 mm2

Ratio 40.67 Pu 6ey 6ex β= 1.00 ACI 11.11.2.1.a req'd n2 = 7.00 8.00 pcs
Formula q= 1± ±
Remark = Safe A B L αs = 40.00 ACI 11.11.2.1.b s (mm) = 128.00 128.00 mm
Overturning about y-y Corner Pressure 1 = 182.45 kPa b1 = 0.51 m
Moment = 41.91 Corner Pressure 2 = 163.31 kPa b2 = 0.51 m
Shear Force = 6.29 Corner Pressure 3 = 77.06 kPa bo = 2.04 m
Total = 41.91 Corner Pressure 4 = 96.21 kPa Critical Area = 0.26 mm2
Resisting about y-y Resultant = 41.42 kN
Footing Weight = 24.49 Check for Shear (Factored Load) γf = 0.60 x-x ACI 13.5.3.2
Soil Weight = 77.21 Wide Beam Shear γf = 0.60 y-y ACI 13.5.3.2
Bouyancy = (10.00) Shear Forces calculated as the volume of γv_x = 0.40 x-x ACI 11.11.7.1
Axial = 286.67 bearing pressures γv_y = 0.40 y-y ACI 11.11.7.1
Total = (11.11) Corner Pressure 1 = 0.470 MPa 𝐽ൗ 0.0956 N/mm2 x-x
𝑐1
Ratio = 9.03 Corner Pressure 2 = 0.430 MPa 0.0956 N/mm2 y-y
Remark = Safe Corner Pressure 3 = 0.570 MPa Vu = 0.99 ACI 11.11.5.2.a
Sliding Calculation Corner Pressure 4 = 0.330 MPa φVu = 1.71 ACI 11.11.5.2.b
kp = 2.78 Maximum Stress = 0.570 MPa Calculation of RC punching shear resistance
Pressure mid d = 83.75 without shear reinforcement (φVn = φVc)
Ultimate Shear Capacity
X-Passive Force = 52.76 Vc = φ0.166λ√f'c - ACI 22.5.5.1 Vc (N/mm2) = 2.32 ACI 11.11.2.1.a
Y-Passive Force = 52.76 Reduction factor φ = 0.750 Vc (N/mm2) = 2.67 ACI 11.11.2.1.b
Friction force = 189.19 λ= 1.000 Vc (N/mm ) =
2
1.50 ACI 11.11.2.1.c
Safe Factor x-x = 13.45 Vc = 0.580 MPa φVc (N/mm2) = 1.13
Safe Factor y-y = 49.42 Ratio = 0.983 Ratio = 0.878
Remark = Safe Remark = Safe for beam shear! Remark = Safe for punching shear!

This spreadsheets is licensed only to

Engr. Mark Christian D. Esguerra

You might also like