F1
F1
LOGO Owner :
Location : BURAUEN LEYTE
Check by : Engr. Mark Christian D. Esguerra
Mark :
Date :
F1
5/1/2022
ISOLATED FOOTING
0.25 m
140.00 kPa Length = 1.80 m Cover (mm) = 75.00
1.8 m
γ= 18.00 kN/m3 Width = 1.80 m
Thickness = 0.35 m 0.25 m
Depth = 1.50 m
Applied forces:
Load Case Pu Mx My Fx Fy
qa factor
Units kN kN.m kN.m kN kN
Service Load = 318.52 7.59 35.62 17.98 4.90 1.33
1.8 m
Factored Load = 414.19 8.60 49.87 22.83 3.56 1.00
Check for Soil Pressures (Service Load) Check for Stability (Service Load)
Location Total Pressure Remark Overturning Sliding
Corner 1= 182.45 kPa x-x y-y
x-x y-y
Corner 2= 163.31 kPa Overturn Resisting Overturn Resisting
Corner 3= 77.06 kPa 9.30 378.37377 41.91 378.37377 Ratio Ratio
Corner 4= 96.21 kPa 40.66506663 9.027295103 13.45 49.42
Ratio 0.98 Safe Safe Safe Safe
Ratio 40.67 Pu 6ey 6ex β= 1.00 ACI 11.11.2.1.a req'd n2 = 7.00 8.00 pcs
Formula q= 1± ±
Remark = Safe A B L αs = 40.00 ACI 11.11.2.1.b s (mm) = 128.00 128.00 mm
Overturning about y-y Corner Pressure 1 = 182.45 kPa b1 = 0.51 m
Moment = 41.91 Corner Pressure 2 = 163.31 kPa b2 = 0.51 m
Shear Force = 6.29 Corner Pressure 3 = 77.06 kPa bo = 2.04 m
Total = 41.91 Corner Pressure 4 = 96.21 kPa Critical Area = 0.26 mm2
Resisting about y-y Resultant = 41.42 kN
Footing Weight = 24.49 Check for Shear (Factored Load) γf = 0.60 x-x ACI 13.5.3.2
Soil Weight = 77.21 Wide Beam Shear γf = 0.60 y-y ACI 13.5.3.2
Bouyancy = (10.00) Shear Forces calculated as the volume of γv_x = 0.40 x-x ACI 11.11.7.1
Axial = 286.67 bearing pressures γv_y = 0.40 y-y ACI 11.11.7.1
Total = (11.11) Corner Pressure 1 = 0.470 MPa 𝐽ൗ 0.0956 N/mm2 x-x
𝑐1
Ratio = 9.03 Corner Pressure 2 = 0.430 MPa 0.0956 N/mm2 y-y
Remark = Safe Corner Pressure 3 = 0.570 MPa Vu = 0.99 ACI 11.11.5.2.a
Sliding Calculation Corner Pressure 4 = 0.330 MPa φVu = 1.71 ACI 11.11.5.2.b
kp = 2.78 Maximum Stress = 0.570 MPa Calculation of RC punching shear resistance
Pressure mid d = 83.75 without shear reinforcement (φVn = φVc)
Ultimate Shear Capacity
X-Passive Force = 52.76 Vc = φ0.166λ√f'c - ACI 22.5.5.1 Vc (N/mm2) = 2.32 ACI 11.11.2.1.a
Y-Passive Force = 52.76 Reduction factor φ = 0.750 Vc (N/mm2) = 2.67 ACI 11.11.2.1.b
Friction force = 189.19 λ= 1.000 Vc (N/mm ) =
2
1.50 ACI 11.11.2.1.c
Safe Factor x-x = 13.45 Vc = 0.580 MPa φVc (N/mm2) = 1.13
Safe Factor y-y = 49.42 Ratio = 0.983 Ratio = 0.878
Remark = Safe Remark = Safe for beam shear! Remark = Safe for punching shear!