Aivres White Paper KR1180 E2 v1
Aivres White Paper KR1180 E2 v1
Applicable Model
Model Maintenance Cooling
KR1180-E2-A0-R0-00 Rear access Air cooling
Technical Support
Global Service Hotline: (+1) 844-912-0007
Address: 1501 McCarthy Blvd, Milpitas, CA 95035
AIVRES SYSTEMS INC.
Website: https://aivres.com
Email: [email protected]
Environmental Protection
Please dispose of product packaging by recycling at a local recycling center for a
greener planet.
Trademarks
All the trademarks or registered trademarks mentioned herein may be the property of
their respective holders. This document does not mark any product or brand with the
symbol ® or ™.
Security Statement
We are intensely focused on server product safety and have placed a high priority on
this. For a better understanding of our server products, carefully read through the
following security risk statements.
External ports of our servers do not use private protocols for communication.
Our products will not initiatively obtain or use your personal data. Only when you
consent to use certain functions or services, some personal data such as IP address
and email address for alerts may be obtained or used during business operation or
fault location. We have implemented necessary measures on product functions to
ensure personal data security throughout the data lifecycle, including but not
limited to data collection, storage, use, transmission, and destruction. Meanwhile,
you are obligated to establish necessary user privacy policies in accordance with
applicable national/regional laws and regulations to fully protect user personal
data.
We will remain committed to the safety of our products and solutions to achieve
better customer satisfaction. We have established emergency response procedures
and action plans for security vulnerabilities, so that product safety issues can be
dealt with in a timely manner. Please contact us for any safety problems found or
necessary support on security vulnerabilities when using our products.
Disclaimer
The purchased products, services and features shall be bound by the contract made
between the customer and us. All or part of the products, services and features
described herein may not be within your purchase or usage scope. Unless otherwise
agreed in the contract, we make no express or implied statement or warranty on the
contents herein. Images provided herein are for reference only and may contain
information or features that do not apply to your purchased model. This document is
only used as a guide. We shall not be liable for any damage, including but not limited
to loss of profits, loss of information, interruption of business, personal injury, or any
consequential damage incurred before, during, or after the use of our products. We
assume you have sufficient knowledge of servers and are well trained in protecting
yourself from personal injury or preventing product damage during operation and
maintenance. The information in this document is subject to change without notice. We
shall not be liable for technical or editorial errors or omissions contained in this
document.
Preface
Abstract
This document describes the KR1180V2 AMD-based server's appearance, features,
performance parameters, and software and hardware compatibility, providing in-
depth information of KR1180V2.
Intended Audience
This document is intended for pre-sales engineers.
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol Description
Revision History
Version Date Description of Changes
2 Features .......................................................................................................2
5.12 Boards........................................................................................................... 27
10 System Management.................................................................................. 52
11 Certifications .............................................................................................. 59
12 Appendix A ................................................................................................. 60
13.1 A - E .............................................................................................................. 67
13.2 F - J ................................................................................................................ 69
13.3 K - O .............................................................................................................. 70
13.4 P - T ............................................................................................................... 71
13.5 U - Z .............................................................................................................. 73
1 Product Overview
The KR1180V2 AMD-based system is a cost-effective high-density 1U single-socket
rack server powered by the AMD EPYC 9004 series processor. Featuring multiple
cores, high base frequency, and high scalability, the server offers ultimate
computing performance, balanced network, and expansion capabilities in a
compact 1U space, saving server room space. It is suitable for various application
scenarios, including cloud computing, virtualization, big data, and distributed all-
flash storage.
1
2 Features
2.1 Scalability and Performance
Table 2-1 Scalability and Performance
2
Technical Feature Description
12 Gbps Serial Doubles the internal storage data transfer rate of 6 Gbps
Attached SCSI SAS, maximizing the performance of storage I/O-intensive
(SAS) applications.
IOD and PCIe 5.0 controllers are integrated into processors,
Infinity Fabric
significantly shortening I/O latency and enhancing overall
Technology
system performance.
Supports up to 3 rear standard PCIe x16 expansion cards,
PCIe Expansion
namely, 1 FHHL card and 2 HHHL cards.
Two OCP 3.0 slots that can flexibly support
OCP Expansion
1/10/25/40/100/200 Gb hot-plug OCP 3.0 cards
Technical
Description
Feature
Supports hot-swap SAS/SATA/NVMe drives and RAID cards
Hot-swap
with RAID levels 0/1/1E/10/5/50/6/60, RAID cache and data
SAS/SATA/NVMe
protection enabled by the super-capacitor in case of power
Drive
failures.
SSDs are much more reliable than traditional HDDs,
increasing system uptime.
The BMC monitors system parameters in real time and
Reliability
sends alerts in advance, enabling technicians to take
corresponding measures in time to minimize system
downtime.
The LEDs on front and rear panels and the BMC Web GUI
indicate the status of key components and quickly lead
technicians to failed (or failing) components, simplifying
Availability maintenance and speeding up troubleshooting.
Provides 2 hot-swap PSUs with 1+1 redundancy.
Provides 8 hot-swap fan modules with N+1 redundancy.
Maintenance The BMC management network port on the rear panel
Efficiency supports remote BMC O&M, improving O&M efficiency.
3
2.3 Manageability and Security
Table 2-3 Manageability and Security
Technical
Description
Feature
Remote The BMC monitors system operating status and enables
Management remote management.
Allows a network port to serve as a management port and a
service port. The NC-SI feature is disabled by default and can
be enabled/disabled through the BIOS or BMC.
Network Notes:
Controller The NC-SI port supports the following features:
Sideband The NC-SI port can be bonded to any network port of the OCP card or of
Interface (NC-SI) PCIe NIC that supports NC-SI.
Feature Supports the enablement/disablement and configuration of Virtual
Local Area Network (VLAN). VLAN is disabled by default.
Supports IPv6 and IPv4 addresses. IP address, subnet mask, default
gateway, and prefix length of IPv6 address can be configured.
Unified
The industry-standard UEFI improves the efficiency of setup,
Extensible
configuration and update, and simplifies the error handling
Firmware
process.
Interface (UEFI)
Trusted Platform Module (TPM) 2.0 and Trusted Cryptography
TPM & TCM
Module (TCM) provide advanced encryption.
AMD Secure Processor (ASP), a microcontroller within the AMD
AMD Secure
processor that provides enhanced security through
Processor
hardware-based resistance to malicious software attacks.
AMD Secure Encrypted Virtualization (SEV) allows applications
AMD SEV to run in isolated space, helping prevent malicious theft and
modification of critical codes and data.
Firmware
The firmware update mechanism based on digital signatures
Update
prevents unauthorized firmware updates.
Mechanism
UEFI Secure Boot Protects the system from malicious bootloaders.
Hierarchical
Password
Ensures system boot and management security.
Protection in
BIOS
BIOS Secure
Flash and BIOS Reduces attacks from malicious software on the BIOS flash
Lock Enable region.
(BLE)
4
Technical
Description
Feature
Dual-image
Mechanism for Recovers firmware upon detection of corrupted firmware.
BMC and BIOS
BMC Secure Boot Protects BMC from malicious tampering.
BMC Access Flexible BMC access control policies improve BMC
Control Policies management security.
Chassis
Intrusion Enhances physical security.
Detection
5
3 System Parts Breakdown
Figure 3-1 Exploded View
6
4 System Logical Diagram
Figure 4-1 System Logical Diagram
MCIO x8
MCIO x8
MCIO x8
MCIO x8
SATA/PCIe5.0 x8
SATA/PCIe5.0 x8
PCIe5.0 x8
PCIe5.0 x8
PCIe5.0 x8
PCIe5.0 x8
PCIe5.0 x8
PCIe5.0 x8
DDR5 DIMM x24
DIMM1
DIMM0
DIMM1
DIMM0
PCIe5.0 x16
8
x
UMC
MCIO x16
P3
8
x
PCIe5.0 x16
8
x
MCIO x16
P2
8
x
CH-L CH-K CH-J CH-I CH-H CH-G PCIe5.0 x8
Genoa
8
x
P1
Connector
PCIe5.0 x8
OCP3.0
OCP3.0
MCIO x8
8
x
6 7 8 9
SATA/PCIe5.0 x8
MCIO x8
CPU0
x8 x8
DIMM1
DIMM0
DIMM1
DIMM0
DIMM1
DIMM0
DIMM1
DIMM0
DIMM1
DIMM0
DIMM1
DIMM0
P0
SATA/PCIe5.0 x8 MCIO x8
UMC 1 1
P5/WAFL
0 1
UART J25
UART0 COM 内置M.2
R/A MCIO x8
SPI
SPI
Cable to
USB3.1
TF Card
CPU
USB10 PCIE Gen2 x1
P5[3]
APML APML
Internal USB3.1 USB01
80PORT
eSPI
USB3.1 eSPI
ISO
eSPI I2C
USB 3.0 HUB 0
U122 NCSI Conn to OCP0
NCSI Connector to
ISO
USB2. USB2.
USB 3.0 HUB 1 0 0 SmartNIC
J56
OCP0
USB2.
0 FP VGA
Smart NIC
J86 TPM/
USB3.1 TPCM
Buffer
USB2.0 BIOS BIOS
Flash Flash REAR VGA
FRONT 0 1
J6 Buffer
MUX
USB 3.0
USB 2.0 USB3.1
Front Left Panel USB3.1 BMC BMC
USB2.0
REAR Flash Flash
USB 3.0 0 1
USB 3.0
RTL8211
DRAM
PHY
J1
TF Card
DC-SCM
RJ45 Micro USB
The 4th Gen AMD EPYC processor (Genoa), with a TDP up to 400 W.
Up to 24 DDR5 DIMMs.
Supports 2 PCIe 5.0 MCIO x16 connectors, 11 PCIe 5.0 MCIO x8 connectors, and
2 OCP 3.0 connectors (one of which is onboard).
CPU PCIe P0/G3 can be directly connected to the motherboard through SATA
protocol; the motherboard supports up to 32 SATA connectors, with a
maximum speed of 6 Gbps (SATA 3.0).
7
The PCIe RAID card is connected to CPU0 via the PCIe bus, and is connected to
the drive backplane via the SAS signal cable. Multiple local storage
configurations are supported through different drive backplanes.
8
5 Hardware Description
5.1 Front Panel
5.1.1 4 × 2.5-Inch Drive + 4 × 3.5-Inch Drive
Configuration
IMPORTANT
A 3.5-inch drive tray can accommodate a 2.5-inch drive.
9
Item Feature Item Feature
10
5.2.2 3 × PCIe Card Configuration
Figure 5-4 Rear View
Power LED:
- Off = No power
- Solid green = Power-on state
- Solid orange = Standby state
11
Icon Feature Description
Off = Normal
Blinking red (1 Hz) = A warning error is
detected on CPU, memory, power
System Status LED supply, drive, fan, etc.
Solid red = A critical error is detected
on CPU, memory, power supply, drive,
fan, etc.
Off = Normal
Blinking red (1 Hz) = A warning error
Memory Status LED
occurs
Solid red = A critical error occurs
Off = Normal
Blinking red (1 Hz) = A warning error
Fan Status LED occurs
Solid red = A critical error occurs,
including fan failure and fan absence
Off = Normal
Blinking red (1 Hz) = A warning error
Power Status LED
occurs
Solid red = A critical error occurs
Off = Normal
Blinking red (1 Hz) = A warning error
occurs, including Proc Hot, resulting in
System Overheat LED CPU throttling
Solid red = A critical error occurs,
including CPU Thermal Trip/PCH
Hot/MEM hot, etc.
12
Icon Feature Description
Press and hold the button for 6
seconds to force the BMC to reset
Feature Description
VGA Port Enables you to connect a display terminal
USB 3.0 Port Enables you to connect a USB 3.0/2.0 device
USB 2.0 Port Enables you to connect a USB 2.0 device
Enables you to debug and monitor the BMC
System/BMC Serial Port
Enables you to debug and monitor the system
Enables you to manage the server
BMC Management Note:
Network Port It is a Gigabit Ethernet port that supports 100/1,000 Mbps auto-
negotiation.
OCP Network Port Enables you to connect the system to the network
13
5.5 Processor
The server supports 1 processor.
For specific processor options, consult your local sales representative or refer
to 7.2 Hardware Compatibility.
CPU 0
5.6 Memory
5.6.1 DDR5 DIMMs
1. Identification
To determine DIMM characteristics, refer to the label attached to the DIMM and the
following figure and table.
14
Figure 5-6 DIMM Identification
16 GB
32 GB
1 Capacity 64 GB
128 GB
256 GB
1R = Single rank
2R = Dual rank
2S2R = Two ranks of two high
2 Rank(s) stacked 3DS DRAM
2S4R = Four ranks of two high
stacked 3DS DRAM
4R = Quad rank
x4 = 4 bits
3 Data width of DRAM
x8 = 8 bits
4 DIMM slot type PC5 = DDR5
4,800 MT/s
5 Maximum memory speed
5,600 MT/s
15
Within a channel, populate the DIMM slot with its silk screen ending with D1 first.
For instance, within CPU0 Channel A, populate CPU0_CAD1 first. To install DIMMs,
refer to the recommended DIMM population rules.
3. Compatibility
Refer to the following rules to configure the DDR5 DIMMs.
IMPORTANT
A server must use DDR5 DIMMs bearing the same part number (P/N code).
All DDR5 DIMMs operate at the same speed, which is the lowest of:
- Memory speed supported by a specific CPU.
- Maximum operating speed of a specific memory configuration.
16
Mixing DDR5 DIMM specifications (capacity, bit width, rank, height, etc.) is
not supported.
For specific memory options, consult your local sales representative or refer to
7.2 Hardware Compatibility.
DDR5 DIMMs can be used with AMD EPYC processors (Genoa). The maximum
memory capacity supported is identical for different CPU models.
The total memory capacity is the sum of the capacities of all DDR5 DIMMs.
NOTE
Maximum number of DIMMs supported per channel ≤ Maximum number of ranks
supported per channel ÷ Number of ranks per DIMM.
Item Value
Capacity per DDR5
16 32 64 128
DIMM (GB)
Type RDIMM RDIMM RDIMM RDIMM
Rated speed (MT/s) 4,800 4,800 4,800 4,800
Operating voltage (V) 1.1 1.1 1.1 1.1
Maximum number of
DDR5 DIMMs 24 24 24 24
supported in a server 1
Maximum capacity of
DDR5 DIMMs
384 768 1,536 3,072
supported in a server
(GB)2
Actual 1DPC3 4,800 4,800 4,800 4,800
speed
2DPC 3,600 3,600 3,600 3,600
(MT/s)
Notes:
1. The maximum number of DDR5 DIMMs supported is based on 2DPC. The number is halved for 1
DPC.
2. It indicates the maximum memory capacity supported when all the DIMM slots are populated with
DDR5 DIMMs.
3. DIMM Per Channel (DPC) is the number of DIMMs per memory channel.
The above information is for reference only. Consult your local sales representative for details.
17
4. DIMM Population Rules
General population rules for DDR5 DIMMs:
Install DIMMs only when the corresponding processor has been installed.
18
5.7 Storage
5.7.1 Drive Configurations
NOTE
For the physical drive No. of each configuration, refer to 5.7.2 Drive Numbering.
Drive
Configuration Front Drives Internal Drives Management
Mode
4 × 2.5-/3.5- 4 × 2.5-/3.5-inch drive M.2 SSD: SAS/SATA
Inch Drive + 4 × + 4 × 2.5-inch drive: Configured drive:
2.5-Inch Drive Drive bays with through the SAS/RAID
Config. physical drive No. 0 to internal M.2 card or
7 support adapter that directly
SAS/SATA/NVMe supports two connected to
drives only SATA/PCIe M.2 the CPU
SSDs NVMe drive:
directly
connected to
the CPU
Internal M.2
SSD: directly
connected to
the CPU
10 × 2.5-Inch 10 × 2.5-inch drive: M.2 SSD: SAS/SATA
Drive Config. Drive bays with Configured drive:
physical drive No. 0 to through the SAS/RAID
9 support internal M.2 card or
SAS/SATA/NVMe adapter that directly
drives only supports two connected to
SATA/PCIe M.2 the CPU
SSDs NVMe drive:
directly
connected to
the CPU
Internal M.2
SSD: directly
connected to
the CPU
19
Drive
Configuration Front Drives Internal Drives Management
Mode
8 × 2.5-Inch 8 × 2.5-inch drive: M.2 SSD: SAS/SATA
Drive + 2 × PCIe Drive bays with Configured drive:
Card Config. physical drive No. 0 to through the SAS/RAID
7 support internal M.2 cards or
SAS/SATA/NVMe adapter that directly
drives only supports two connected to
SATA/PCIe M.2 the CPU
SSDs NVMe drive:
directly
connected to
the CPU
Internal M.2
SSD: directly
connected to
the CPU
Drive No.
Drive No.
Physical Identified by
Configuration Identified by Front/Rear
Drive No. the 8i RAID
the BMC
Card
8 × SAS/SATA 0 to 7 0 to 7 Front 0 to 7
8 × NVMe 0 to 7 0 to 7 Front -
20
Drive No.
Drive No.
Physical Identified by
Configuration Identified by Front/Rear
Drive No. the 16i RAID
the BMC
Card
10 × SAS/SATA 0 to 9 0 to 9 Front 0 to 9
10 × NVMe 0 to 9 0 to 9 Front -
Activity LED
Locator/Error LED (②)
(①) Description
21
2. NVMe Drive LEDs
Figure 5-11 NVMe Drive LEDs
For specific RAID card options, consult your local sales representative or refer to 7.2
Hardware Compatibility.
5.8 Network
NICs provide network expansion capabilities.
The OCP slots support OCP 3.0 cards. Users can select the OCP 3.0 cards as
needed.
22
The PCIe expansion slots support PCIe NICs. Users can select the PCIe NICs as
needed.
For specific NIC options, consult your local sales representative or refer to 7.2
Hardware Compatibility.
The rear panel supports up to 3 PCIe expansion slots and 2 dedicated slots for
OCP 3.0 cards.
For specific PCIe expansion card options, consult your local sales
representative or refer to 7.2 Hardware Compatibility.
23
5.9.3 PCIe Riser Modules
Figure 5-14 PCIe Riser Module 0/1 (One PCIe x16 Slot)
Slot0/Slot1
Slot0
Slot1
Slot2
24
5.9.4 PCIe Slot Description
Table 5-8 PCIe Slot Description - 2 × PCIe Card Configuration
5.10 PSUs
The server supports 1 or 2 PSUs.
The server must use PSUs bearing the same part number (P/N code).
25
Figure 5-17 PSU Locations
PSU0 PSU1
The server supports fans in N+1 redundancy, which means that the server can
continue working properly when a single fan fails.
The server must use fan modules bearing the same part number (P/N code).
26
5.12 Boards
5.12.1 Motherboard
Figure 5-19 Motherboard Layout
27
Item Feature Item Feature
Intrusion Detection
18 43 Riser Power Connector
Connector
28
Figure 5-20 4 × 2.5-Inch SAS/SATA/NVMe Drive Backplane
4 Slimline x4 Connector - -
29
10 × 2.5-Inch SAS/SATA/NVMe Drive Configuration
2 BMC_I2C Connector - -
30
Figure 5-25 2 × 2.5-Inch SAS/SATA Drive Backplane
31
6 Product Specifications
6.1 Technical Specifications
Table 6-1 Technical Specifications
Item Description
Form Factor 1U rack server
Supports 1 processor.
4th Gen AMD EPYC processor (Genoa)
Integrated memory controllers and 12 memory channels
per processor
Integrated PCIe 5.0 controllers and 128 PCIe lanes per
processor
Processor
Up to 128 cores
Max boost frequency of 4.40 GHz
L3 cache up to 384 MB
TDP up to 400 W
Note: The information above is for reference only. See 7.2 Hardware
Compatibility for details.
32
Item Description
- 2 × SATA/PCIe M.2 SSD
- 1 × VGA port
Rear:
Port - 2 × USB 3.0 port
- 1 × VGA port
- 1 × system/BMC serial port (Micro USB)
- 1 × BMC management network port
Note:
OS installation on the USB storage media is not recommended.
UEFI
System BMC
Management NC-SI
KSManage
33
Item Description
AMD SEV
Firmware update mechanism based on digital signatures
UEFI Secure Boot
Hierarchical BIOS password protection
BIOS Secure Flash and BIOS Lock Enable (BLE)
BMC and BIOS dual-image mechanism
Chassis intrusion detection
Parameter Description
Operating: 5% to 90% RH
Relative Humidity (RH,
Storage (packed): 5% to 95% RH
non-condensing)
Storage (unpacked): 5% to 95% RH
Operating: 0 to 3,050 m (0 to 10,007 ft)
Altitude
Shipping (storage): 0 to 12,000 m (0 to 39,370 ft)
Maximum growth rate of corrosion film thickness:
Copper coupon: 300 Å/month (compliant with
the gaseous corrosivity level of G1 defined in
Corrosive Gaseous
ANSI/ISA-71.04-2013)
Contaminants
Silver coupon: 200 Å/month (compliant with the
gaseous corrosivity level of G1 defined in
ANSI/ISA-71.04-2013)
Noise emissions are measured in accordance with ISO
7779 (ECMA 74) and declared in accordance with ISO
9296 (ECMA 109). Listed are the declared A-weighted
sound power levels (LWAd) and the declared average
Acoustic Noise2,3,4,5 bystander position A-weighted sound pressure levels
(LpAm) at a server operating temperature of 23°C
(73°F):
Idle:
34
Parameter Description
Operating:
- LWAd: 6.9 Bels for standard configuration
- LpAm: 53.5 dBA for standard configuration
Notes:
- 10°C to 35°C (50°F to 95°F) is the standard operating temperature range at sea level. From sea
level to an altitude of 3,050 m (10,007 ft), derate the maximum allowable operating temperature
by 1°C per 305 m (1°F per 556 ft). No direct sustained sunlight is permitted. The maximum
temperature gradient is 20°C/h (36°F/h) and the maximum operating altitude is 3,050 m (10,007
ft), both varying with server configuration.
- Any fan failure or operations above 30°C (86°F) may lead to system performance degradation.
2. This document lists the LWAd and LpAm of the product at a 23°C (73.4°F) ambient environment. All
measurements are conducted in conformance with ISO 7779 (ECMA 74) and declared in conformance
with ISO 9296 (ECMA 109). The listed sound levels apply to the standard configuration. Additional
options may result in increased sound levels. Contact your sales representative for more information.
3. The sound levels shown here were measured based on specific configurations of a server. Sound
levels vary by server configuration. These values are for reference only and subject to change without
notice.
5. The listed sound levels apply to the standard configuration. Additional options may result in
increased noise.
Item Description
Outer Packaging
1,090 × 600 × 240 mm (42.91 × 23.62 × 9.45 in.)
Dimensions (L × W × H)
Installation requirements for the cabinet are as
follows:
35
Item Description
36
Figure 6-1 Chassis Dimensions
Zc
Zb
Za
Xa Xb
Ya
Model Za Zb Zc Xa Xb Ya
KR1180-
850 mm 879 mm 30 mm 482 mm 431 mm 43.05 mm
E2-A0-R0-
(33.46 in.) (34.61 in.) (1.18 in.) (18.98 in.) (16.97 in.) (1.69 in.)
00
37
7 Operating System and Hardware
Compatibility
This section describes the OS and hardware compatibility of the server. For the
latest compatibility configuration and the component models not listed in this
document, contact your local sales representative.
IMPORTANT
Using incompatible components may cause the server to work abnormally,
and such failures are not covered by technical support or warranty.
The hardware compatibility of different models may vary slightly. Contact
your sales representatives to confirm the detailed hardware configurations
during the pre-sales phase.
The server performance is strongly influenced by application software,
middleware and hardware. The subtle differences in them may lead to
performance variation in the application and test software.
- For requirements on the performance of specific application software,
contact our sales representatives to confirm the detailed hardware and
software configurations during the pre-sales phase.
- For requirements on hardware performance consistency, define specific
configuration requirements (for example, specific drive models, RAID
cards, or firmware versions) during the pre-sales phase.
OS Version
Red Hat Enterprise Linux 9.1
CentOS 8.5
Ubuntu 20.04.5
OpenEuler 22.03
38
OS Version
Debian 11.2
NOTE
After installing Linux OS, add iommu=pt in the OS. See the OS installation guide
on our website for details.
39
Table 7-3 DIMM Specifications
Capacity
Type Rate (MT/s) Data Width Organization
(GB)
RDIMM 16 4,800 x72 1R x8
RDIMM 32 4,800 x72 2R x8
RDIMM 64 4,800 x72 2R x4
40
Type Capacity Max. Qty.
M.2 SATA SSD 240 GB 2
Type Description
SAS Card_PM8222_SmartHBA_8_SAS3_PCIE3
SAS Card
SAS Card_BRCM_8R0_9500-8i_SMSAS3_PCIE4
RAID Card_PM8204_RA_8_2GB_SAS3_PCIE3
RAID Card
RAID Card_L_8R0_9560-8i_4G_HDM12G_PCIE4
Speed Port
Type Description
(Gbps) Qty.
NIC_Andes-6_X710_10G_LC_OCP3x8_2 10 2
NIC_SND_1G_I350_RJ_OCP3x4_2_XR 1 2
NIC_Andes-M6_E810_25G_LC_OCP3x8_2 25 2
NIC_I_100G_E810CQDA2_LC_OCP3x16_2_XR 100 2
OCP 3.0 Card
NIC_M_100G_MCX623436AN_LC_OCP3x16_2_XR 100 2
NIC_M_25G_MCX623432AN_LC_OCP3x16_2_XR 25 2
NIC_ I_25G_E810XXVDA2_LC_OCP3x8_2_XR 25 2
NIC_ Andes-M6_E810_25G_LC_OCP3x8_2 25 2
Speed
Type Description Port Qty.
(Gbps)
NIC_I_10G_EX710DA2_LC_PCIEx8_2_XR_Lmt 10 2
NIC_I_25G_E810XXVDA2_LC_PCIEx8_2_XR 25 2
PCIe NIC NIC_M_100G_MCX623106AN_LC_PCIEx16_2_XR 100 2
NIC_M_25G_MCX631102AN_LC_PCIEx8_2_XR 25 2
NIC_ I_25G_E810XXVDA2_LC_OCP3x8_2_XR 25 2
41
7.2.6 HBA/HCA Card Specifications
Table 7-11 HBA Card Specifications
Type Description
Speed
Type Description Port Qty.
(Gbps)
HCA Card HCA Card_M_1-HDR100_MCX653105A-ECAT_PCIE 100 1
HCA Card HCA Card_ M_2-HDR100_MCX653106A-ECAT_PCIE 100 2
The following rated 110 Vac to 230 Vac PSUs in 1+1 redundancy are supported:
42
The following rated -48 Vdc PSUs in 1+1 redundancy are supported:
43
8 Regulatory Information
8.1 Safety
8.1.1 General
Strictly comply with local laws and regulations while installing the equipment.
The safety instructions in this section are only a supplement to local safety
regulations.
Stop any operation that could cause personal injury or equipment damage.
Report to the project manager and take effective protective measures.
Do not carry the weight over the maximum load per person allowed by local
laws or regulations. Arrange appropriate installation personnel and do not
overburden them.
Installation personnel must wear clean work clothes, work gloves, safety
helmets and safety shoes, as shown in Figure 8-1.
44
Figure 8-1 Protective Clothing
Before touching the equipment, put on ESD clothes and ESD gloves or an ESD
wrist strap, and remove any conductive objects such as wrist watches or metal
jewelry, as shown in Figure 8-2, in order to avoid electric shock or burns.
c. Plug the alligator clip of the ESD wrist strap into the corresponding jack on the
grounded cabinet or grounded chassis.
45
Figure 8-3 Wearing an ESD Wrist Strap
When moving or lifting equipment above shoulder height, use lifting devices
and other tools as necessary to avoid personal injury or equipment damage
due to equipment slippage.
The power sources of the server carry a high voltage. Direct contact or indirect
contact through damp objects with the high-voltage power source is fatal.
When using ladders, always have someone hold and guard the bottom of the
ladders. In order to prevent injury, never use a ladder alone.
When connecting, testing or replacing optical fiber cable, avoid looking into
the optical port without eye protection in order to prevent eye damage from
laser light.
Before touching the equipment, put on ESD clothing and ESD gloves to prevent
static electricity from damaging the equipment.
When moving the server, hold the bottom of the server. Do not hold the
handles of any module installed in the server, such as PSUs, fan modules,
drive modules, or motherboard. Handle the equipment with care at all times.
Connect the power cords of active and standby PSUs to different PDUs to
ensure high system reliability.
46
To ensure equipment safety, always ground the equipment before powering it
on.
CAUTION
Observe local laws or regulations regarding the manual handling weight limits
per person. The limits shown on the equipment and in the document are
recommendations only.
Table 8-1 lists the manual handling weight limits per person specified by some
organizations.
47
9 Limited Warranty
This limited warranty applies only to the original purchasers of our products who
are direct customers or distributors of us (“Customer”).
We warrant all our hardware products, if properly used and installed, to be free
from defects in material and workmanship within the warranty period. The term
“Hardware Product” is limited to the hardware components and required firmware.
The term “Hardware Product” DOES NOT include software applications or
programs, and DOES NOT include products or peripherals that are not supplied by
us. We may, at our discretion, repair or replace the defective parts. Repair or
replacement parts may be new, used, or equivalent to new in performance and
reliability. Repair or replacement parts are warranted to be free of defects in
material or workmanship for ninety (90) calendar days or for the remainder of the
warranty period of the product, whichever is longer.
System serial number, part number, model and location (address) of the
product needing service
Detailed description of problem, logs (SELs and blackbox logs, and any other
related logs from OS), screenshot of issue, pictures of damaged/faulty parts,
etc.
48
9.1.2 RMA Service
Standard Replacement: When a hardware failure occurs, Customer may submit an
RMA request to us via e-mail or Service Portal*1. We will review and approve the
RMA submission at our own discretion, and provide an RMA number and return
information that Customer may use to return the defective part(s) for the RMA
service. We will ship out replacement part(s) within one (1) business day after
receiving the defective part(s) and cover one-way shipment.
NOTE
Customer should return the defective parts in original packaging to our
designated service center at their own expense.
After our further diagnosing and testing, if the defective parts conform to
our repair policy, we will ship out the repair or replacement parts at our own
expense; otherwise, we will return the defective parts at Customer’s
expense.
If Customer needs to designate a logistics company, allocation of the
shipping cost to us/Customer will be redefined.
NOTE
Customer should return the defective parts in original packaging to our
designated service center.
We will ship out the replacement parts at our own expense after completing
remote diagnosis.
If Customer needs to designate a logistics company, allocation of the
shipping cost to us/Customer will be redefined.
49
Commitment. The response time is measured from the time when the remote
troubleshooting is completed and logged to the arrival of a service engineer and
parts to Customer location for repair.
NOTE
9 × 5 × NBD: Our service engineer typically arrives at the customer’s data center
on the next business day. Service engineers are available on local business day
from 9:00 am to 6:00 pm local time. Calls received/dispatches after 5:00 pm
local time will require an additional day for the service engineer to arrive.
NOTE
24 × 7 × 4: Our service engineer typically arrives at the customer site within 4
hours. Service engineers are available at any time, including weekends and local
national holidays.
RMA Service
ARMA Service
24 × 7 × 4 Onsite Service
50
Products.
expendable or consumable parts, such as, but not limited to, batteries or
protective coatings that are designed to diminish over time, unless failure has
occurred during DOA period due to a defect in material or workmanship;
any cosmetic damage, such as, but not limited to, scratches, dents, broken
plastics, metal corrosion, or mechanical damage, unless failure has occurred
during DOA period due to a defect in material or workmanship;
any solid-state drive (SSD) which has reached its write endurance limit.
In no event will we be liable for any direct loss of use, interruption of business,
lost profits, lost data, or indirect, special, incidental or consequential damages
of any kind regardless of the form of action, whether in contract, tort (including
negligence), strict liability or otherwise, even if we have been advised of the
possibility of such damage, and whether or not any remedy provided should
fail of its essential purpose.
*1 Service Portal availability is subject to customer type and customer location. Please contact your
representative to learn more.
*2 Not all SLA offerings are available at all customer locations. Some SLA offerings may be limited to
geolocation and/or customer type. Please contact your representative to learn more.
51
10 System Management
10.1 Intelligent Management System BMC
BMC, a remote server management system, supports mainstream management
specifications in the industry such as IPMI 2.0 and Redfish 1.13. BMC features high
operational reliability, easy serviceability for different business scenarios, accurate
and comprehensive fault diagnosis capabilities, and industry-leading security
reinforcement capabilities.
BMC supports:
IPMI 2.0
Redfish 1.13
SNMP v1/v2c/v3
Feature Description
Supports extensive remote management interfaces for
various server O&M scenarios. The supported interfaces
include:
IPMI
SMASH CLP
SNMP
Management
Interface HTTPS
Web GUI
Redfish
RESTful
DCMI
Syslog
Accurate and IDL, a fault diagnosis system, offers accurate and
Intelligent Fault comprehensive hardware fault location capabilities, and
Location outputs detailed fault causes and handling suggestions.
52
Feature Description
Supports rich automatic remote alert capabilities, including
Alert proactive alerting mechanisms such as SNMP Trap
Management (v1/v2c/v3), email alerts and syslog remote alerts to ensure
24 × 7 reliability.
Supports HTML5- and Java-based remote console to remotely
Remote Console control and operate the monitor/mouse/keyboard of the
KVM server, providing highly available remote management
capabilities without on-site operation.
Virtual Network Supports mainstream third-party VNC clients without relying
Console (VNC) on Java, improving management flexibility.
Supports virtualizing images, USB devices, folders and local
Remote Virtual
media devices as media devices of remote servers,
Media
simplifying OS installation, file sharing, and other O&M tasks.
Supports the visual management interface developed by us,
Web GUI displaying abundant information of the server and
components, and offers easy-to-use Web GUIs.
Supports automatic crash screenshot and crash video
Crash Screenshot recording (video needs to be enabled manually) to capture
and Crash Video the last screen and video before crash; provides manual
Recording screenshot, which can quickly capture the screen for easy
inspection at scheduled time.
Supports dual flash and dual image, enabling automatic
Dual Flash and
flash failover in case of software or flash corruption,
Dual Image
improving operational reliability.
Supports power capping, increasing deployment density and
Power Capping
reducing energy consumption.
Supports both IPv4 and IPv6, enhancing network deployment
IPv4/IPv6
flexibility.
Supports auto-switching between the dedicated
Auto-Switching management network port and shared management
of Management network port, providing customers with flexible network
Network Port deployment solutions for different management network
deployment scenarios.
Supports the reliable dual watchdog mechanism for
hardware and software, enabling automatic restoration
of BMC in case of BMC abnormality.
BMC Self-
Provides a thermal protection mechanism, which is
Diagnosis and
automatically triggered when the BMC is abnormal to
Self-Recovery
ensure that the fan operates at safe speeds to avoid
System
system overheating.
Supports self-diagnosis of processors, memory modules,
and storage devices of BMC, and automatically cleans
53
Feature Description
the workload to restore to normal when the device
usage rate is too high.
Supports virtual power buttons for power on/off, power cycle
Power Control
and reset.
Supports remote lighting of the UID LED for locating the
UID LED
server in the server room.
Supports firmware update based on secure digital
signatures, and mismatch prevention mechanism for
Secure Firmware
firmware from different manufacturers and firmware for
Update
different server models; supports firmware update of
BMC/BIOS/CPLD/ PSU.
Supports remote redirection of the system serial port, BMC
Serial Port serial port and other serial ports, and directs the server-side
Redirection serial port output to the local administrator via the network
for server debugging.
Storage Displays RAID logical array information and drive
Information information, and supports remote RAID creation for improved
Display deployment efficiency.
Supports user detail management based on user roles and
User Role flexible creation of user roles with different privileges, and
Management provides more user roles to allow administrators to grant
different privileges to O&M personnel.
Adopts the industry-leading server security baseline
standard V3.0. SSH, HTTPS, SNMP and IPMI use secure and
Security Feature reliable algorithms. BMC offers capabilities including secure
update and boot and security reinforcement mechanisms
such as anti-replay, anti-injection, and anti-brute force.
Supports double factor authentication for local BMC users.
Double Factor Users need to log in to the BMC with both password and
Authentication certificate, thus to prevent attacks caused by password
leakage.
Configuration
Exporting and Imports and exports the existing system configurations.
Importing
Displays the server basic information such as the information
System
and health status of key server components, including CPU,
Information
memory, power supply, device inventory, hard drive, network
Display
adapter, and security chip.
Displays the status, current speed, duty ratio, and other
Fan information of a fan module. You can select the fan control
Management mode and preset the speed for each fan module in the
Manual Fan Control mode.
54
Feature Description
Sets how the server operating system reacts under the BMC's
Power Policy
control when AC power is reconnected to the server.
Performs non-recoverable erasing on all storage devices of
One-Click
the server, preventing data leakage when the server is to be
Erasing
retired.
After this feature is enabled, some parameters of the server
System
cannot be set and some operations cannot be performed on
Lockdown
the server.
10.2 KSManage
The server is compatible with the latest version of KSManage, a new-generation
infrastructure O&M management platform for data centers.
Built on cutting-edge O&M concepts, KSManage provides users with leading and
efficient overall management solutions for data centers to ensure advanced
infrastructure management. This platform provides a rich set of functions such as
centralized asset management, in-depth fault diagnosis, component fault early
warning, intelligent energy consumption management, 3D automatic topologies,
and stateless automatic deployment. With these functions, users can implement
centralized O&M of servers, storage devices, network devices, security devices, and
edge devices, effectively improving O&M efficiency, reducing O&M costs, and
ensuring the secure, reliable, and stable operation of data centers. KSManage
offers:
55
Table 10-1 KSManage Features
Feature Description
56
Feature Description
Secure and quick drive data erasing
CPU and memory stress test
Automatic firmware baseline management
BMC and BIOS snapshot management
Repositories for update files
57
10.3 KSManage Tools
Table 10-2 Features of KSManage Tools
Feature Description
58
11 Certifications
Table 11-1 Certifications
59
12 Appendix A
12.1 Thermal Restrictions
Table 12-1 Thermal Restrictions
Inch supported
10 × 2.5-inch
Drive NVMe/SAS/SATA drive 1 PCIe expansion card
Config. supported supported
60
Non-perforated Non-perforated
chassis not supported chassis not supported
NOTE
The maximum operating temperature will drop by 5°C (9°F) if a single fan
fails.
Single fan failure may affect system performance.
When the front bezel is used with any of the following, the maximum
operating temperature will drop by 3°C (5.4°F): 100 Gb OCP 3.0 cards, 360 W
TDP CPUs, 10 × 2.5-inch drive configuration, 4 × 3.5-inch drive + 4 × 2.5-
inch drive configuration, or GPUs.
Consult your sales representative for detailed component combination
restrictions.
12.2 Model
Table 12-2 Model
61
features. By configuring these features, the server can provide greater reliability,
availability, and serviceability.
Sensor
Sensor Description Note
Location
Chassis air inlet Right mounting
Inlet_Temp
temperature ear
Chassis air outlet
Outlet_Temp Motherboard
temperature
CPU core
CPU0_Temp CPU
temperature
VR chip on the
CPU0_VR_Temp CPU VR temperature
motherboard
x indicates the
The maximum
DIMM number
CPU0_DIMMGx_T temperature of the DIMM
with a value of 0
DIMMs of CPU0
to 1
Maximum
Drives attached
temperature among
HDD_MAX_Temp to the drive
all drives connected
backplane
to the RAID card
Maximum Drives attached
NVMe_Temp temperature among to the drive
all NVMe drives backplane
PSU inlet
PSU_Inlet_Temp PSU
temperature
OCP card
OCP_0_NIC_Temp OCP card
temperature
The temperature of
SFP optical
the SFP optical
OCP_0_SFP_Temp module on the
module on the OCP
OCP card
card
Maximum
PCIe_NIC_Temp temperature among PCIe NIC
all PCIe NICs
The temperature of
SFP optical
the SFP optical
PCIe_SFP_Temp module on the
module on the PCIe
PCIe NIC
NIC
62
Sensor
Sensor Description Note
Location
Maximum
RAID_Temp temperature among RAID cards
all RAID cards
x indicates the
GPUx_Temp GPUx temperature GPU GPU number with
a value of 0 to 2
HBA card
HBA_Temp HBA card
temperature
HCA card
PCIe_HCA_Temp HCA card
temperature
The temperature of
SFP optical
the SFP optical
PCIe_HCA_SFP_T module on the
module on the HCA
HCA card
card
RAID mezz card
OCP_RAID_Temp RAID mezz card
temperature
12 V voltage
SYS_12V supplied by Motherboard
motherboard to BMC
5 V voltage supplied
SYS_5V by motherboard to Motherboard
BMC
3.3 V voltage
SYS_3V3 supplied by Motherboard
motherboard to BMC
5 V voltage of
standard power
P5V_STBY Motherboard
connectors on the
motherboard
3.3 V voltage of
standard power
P3V3_STBY Motherboard
connectors on the
motherboard
1.8 V voltage of
standard power
P1V8_STBY Motherboard
connectors on the
motherboard
1.05 V voltage
P1V05_USB supplied to USB Motherboard
module
63
Sensor
Sensor Description Note
Location
The voltage supplied
PVDD33_S5 Motherboard
by VR chip to CPU
The voltage supplied
PVDDCR_CPU0_P0 Motherboard
by VR chip to CPU
The voltage supplied
PVDDCR_CPU1_P0 Motherboard
by VR chip to CPU
The voltage supplied
PVDD18_S5_P0 Motherboard
by VR chip to CPU
The voltage supplied
PVDDCR_SOC_P0 Motherboard
by VR chip to CPU
The voltage supplied
PVDD11_S3_P0 Motherboard
by VR chip to CPU
The voltage supplied
PVDDIO_P0 Motherboard
by VR chip to CPU
12 V voltage
supplied by
P12V_CPU0_DIMM1 Motherboard
motherboard to
DIMMs
x indicates the
PSUx_VIN PSUx input voltage PSU PSU number with
a value of 0 to 1
x indicates the
PSUx_VOUT PSUx output voltage PSU PSU number with
a value of 0 to 1
RTC battery on
RTC_Battery RTC battery voltage the
motherboard
x indicates the fan
module number
FANx_Status FANx status FANx
with a value of 0
to 7
Fan redundancy
FAN_Redundant Fan module
status
x indicates the fan
module number
FANx_F_Speed FANx speed in rpm FANx
with a value of 0
to 7
x indicates the fan
module number
FANx_R_Speed FANx speed in rpm FANx
with a value of 0
to 7
64
Sensor
Sensor Description Note
Location
Total_Power Total power PSU
x indicates the
PSUx_PIN PSUx input power PSUx PSU number with
a value of 0 to 1
x indicates the
PSUx_POUT PSUx output power PSUx PSU number with
a value of 0 to 1
FAN_Power Total fan power Fan module
CPU_Power Total CPU power Motherboard
Memory_Power Total memory power Motherboard
CPU0_Status CPU status CPU
CPU configuration
status (mixing of
CPU_Config CPU
CPUs, or primary CPU
not installed)
x indicates the
memory channel
number under the
CPU with a value
CPU0_CxDy CPU DIMM status CPU DIMM of A to L; y
indicates the
DIMM number
with a value of 0
to 1
PCIe_Status PCIe status error PCIe bus
Power button
Power button
Power_Button on the front
pressed
panel
Watchdog2 Watchdog Motherboard
Sys_Health BMC health status BMC
UID_Button UID button status Motherboard
Power capping
PWR_CAP_Fail Motherboard
status
PSU redundancy
PSU_Redundant PSU
status
PSU_Mismatch PSU model mismatch PSU
x indicates the
PSUx_Status PSUx status PSUx PSU number with
a value of 0 to 1
Monitors chassis-
Intrusion Top cover
opening activity
65
Sensor
Sensor Description Note
Location
(chassis intrusion
detection)
Reason for system
SysShutdown
shutdown
ACPI_PWR ACPI status
System software
ME_FW_Status process, system
startup error
Reason for system -
SysRestart
restart
BIOS boot up
BIOS_Boot_Up
complete
Emergency system
System_Error
failure
POST_Status POST status
CPU_Config System hang -
Record the BMC boot
BMC_Boot_Up
event
Record the event that
-
system event logs
SEL_Status
are almost
full/cleared
BMC_Status BMC status -
Leak detection
LeakageSensor -
(reserved)
66
13 Appendix B Acronyms and
Abbreviations
13.1 A - E
A
AC Alternating Current
AI Artificial Intelligence
BP Backplane
67
CB Certification Body
CE Conformite Europeenne
COM Communication
DC Direct Current
68
ESD Electro-static Discharge
EU European Union
13.2 F - J
F
FW Firmware
I/O Input/Output
IC Industry Canada
69
ID Identity
IP Internet Protocol
13.3 K - O
K
KC Korean Certification
LC Lucent Connector
LP Low Profile
70
ME Management Engine
OS Operating System
13.4 P - T
P
PWR Power
71
RAID Redundant Arrays of Independent Disks
RH Relative Humidity
RST Reset
72
TCM Trusted Cryptography Module
TF TransFlash
13.5 U - Z
U
UL Underwriters Laboratories
VM Virtual Machine
VR Voltage Regulator
73