Operat�on Manual
This manual gives detailed description of the precautions that should be brought to your attention during operation.
In order to ensure correct service of the wired controller please read this manual carefully before using the unit.
For convenience of future reference, keep this manual after reading it.
CONTENTS
1 GENERAL SAFETY PRECAUTIONS 01
1.1 About the documentation 01
1.2 For the user 01
4 MENU STRUCTURE 05
4.1 About the menu structure 05
4.2 To go to the menu structure 05
4.3 To navigate in the menu structure 05
5 BASIC USAGE 05
5.1 Screen Unlock 05
5.2 Turning ON/OFF controls 05
5.3 Adjusting the temperature 07
5.4 Adjusting space operation mode 08
6 OPERATION 08
DANGER:
RISK OF ELECTROCUTION
Indicates a situation that could result in
electrocution.
This means that electrical and electronic products can
not be mixed with unsorted household waste. Do NOT try
to dismantle the system yourself: the dismantling of the
system, treatment of the refrigerant, of oil and of other
DANGER: parts must be done by an authorized installer and must
RISK OF BURNING comply with applicable legislation. Units must be treated
at a specialized treatment facility for reuse, recycling and
Indicates a situation that could result in burning recovery. By ensuring this product is disposed of
because of extreme hot or cold temperatures. correctly, you will help to prevent potential negative
consequences for the environment and human health.
For more information, contact your installer or local
authority.
WARNING
Placed in a location away from radiation.
Indicates a situation that could result in death or
serious injury.
CAUTION
Indicates a situation that could result in minor or
moderate injury.
NOTE
Indicates a situation that could result in
equipment or property damage.
i INFORMATION
Indicates useful tips or additional information.
01
2 A GLANCE OF THE USER INTERFACE
2.1 The appearance of the wired controller
Navigate the
cursor on the
display/navigate
in the menu
structure/adjust
the settings Long press for
unlocking /locking
the controller
Come back to
the up level
02
3 USING HOME PAGES
When you turn on the wired controller, the system will enter the language selection page, You can choose your preferred
language, then press to enter the home pages. If you don't press in 60 seconds, the system will enter in the currently
selected language.
EN FR IT ES PL PT
DE NL RO RU TR GR
SE SI CS SK HU HR
You can use the home pages to read out and change settings that are meant for daily usage. What you can see and do on
the home pages is described where applicable. Depending on the system layout, the following home pages may be possible:
Water flow desired temperature
Room desired temperature
Domestic hot water temperature
home page1
If the WATER FLOW TEMP. is set YES and ROOM TEMP. is set NON.(See ''FOR SERVICEMAN'' > ''TEMP. TYPE
SETTING'' in ''Installation and owner's manual ''). The system has the function including floor heating and domestic water,
home page 1 will appear:
UI
SV1
FHL1FHL2...FHLn
NOTE
All the pictures in the manual are used to explain, the actual pages in the screen may have some difference.
home page2
If the WATER FLOW TEMP. is set NON and ROOM TEMP. is set YES(See ''FOR SERVICEMAN'' > ''TEMP. TYPE
SETTING'' on ''Installation and owner's manual ''). The system has the function including floor heating and domestic hot water,
home page 2 will appear:
UI
SV1
FFHL1FHL2.F..HLn
Room desired temperature
NOTE
The wired controller should be installed in the floor heating room to check the room temperature.
03
home page3
If the DHW MODE is set NON (See ''FOR SERVICEMAN'' > ''DHW MODE SETTING '' in ''Installation and owner's manual
'', and if ''WATER FLOW TEMP.'' is set YES, ''ROOM TEMP.'' is set YES,(See ''FOR SERVICEMAN'' > ''TEMP. TYPE
SETTING '' in ''Installation and owner's manual ''). There will be main page and additional page. The system has the
function including floor heating and space heating for fan coil, home page 3 will appear:
Main page
UI
Addition page
FHL1 FHL2...FHLn
2
home page4
If the ROOM THERMOSTAT is set DOUBLE ZONE or DOUBLE ZONE is set YES. There will be main page and addition
page. The system has the function including floor heating, space heating for fan coil and domestic hot water, home page 4
will appear:
Main page
RT=Room thermostat
UI
Zone 1 water flow DHW tank RT1
desired temperature real temperature RT2
FCU1FCU2...FCUn
SV1 SV3
Addition page
FHL1FHL2...FHLn
2
04
4 MENU STRUCTURE The interface will be locked if there is no handing for a
4.1 About the menu structure long time(about 120 seconds:it can be set by the
interface, see ''6.7 SERVICE INFORMATION''.)
You can use the menu structure to read out and
configure settings that are NOT meant for daily usage. If the inerface is unlocked, long press " ", the
What you can see and do in the menu structure is interface will be locked.
described where applicable. For an overview of the
menu structure, see " 7 Menu structure: Overview".
4.2 To go to the menu structure
From a home page, press '' ''.
Result: The menu structure appear
MENU
OPERATION MODE
PRESET TEMPERATURE
Long press Long press
DOMESTIC HOT WATER(DHW)
SCHEDULE
OPTIONS
CHILD LOCK
ENTER
MENU
SERVICE INFORMATION
OPERATION PARAMETER
FOR SERVICEMAN
WLAN SETTING 5.2 Turning ON/OFF controls
SN VIEW
5.2.1 Use the interface to turn on or off the unit for space
ENERGY METERING heating or cooling.
ENTER The ON/OFF of the unit is controlled by the interface
if do not activate ROOM THERMOSTAT.(see ''ROOM
THERMOSTAT SETTING '' in '' Installation and owner's
4.3 To navigate in the menu structure manual'')
Use''▼'' ''▲'' to scroll. Press ''◄ '' ''▲'' on home page, the black cursor will
appear:
5 BASIC USAGE
5.1 Screen Unlock
If the icon is on the screen, the controller is locked.
The following page is displayed:
Press any key, the icon will flash. Long press the
'' '' key. The icon will disappear, the interface
can be controlled.
05
5.2.2 Use the room thermostat to turn on or off the unit
for space heating or cooling.
The room thermostat is set MODE SET (see ''ROOM
THERMOSTAT SETTING'' in ''Installation and owner's
manual ''). The unit operation mode and ON /OFF controlled
by room thermostatpress on the interface, the
following page will display
OFF OFF
2
OFF
OFF
06
5.2.3 Use the interface to turn on or off the unit for DHW.Press 5.3 Adjusting the temperature
''►''''▼''on home page, the black cursor will appear:
Press ''◄ '' ''▲'' on home page, the black cursor will
appear:
OFF
07
The operation mode can not be changed.
If you
Then the space operation mode is…
select…
5.4 Adjusting space operation mode Adjust space operation mode by the room thermostat
, see ''ROOM THERMOSTAT'' on "Installation and
Adjusting space operation mode by interface owner's manual ".
Go to '' '' > ''OPERATION MODE'' . Press" ", Go to '' '' >''OPERATION MODE'', if you press
the following page will appear: any key to select or adjust, the page will appear:
OPERATION MODE
Operation mode setting:
Cool/heat mode is controlled by
HEAT COOL AUTO
the room thermostat.
A
Please adjust the operation mode
by the room thermostat.
CONFIRM CONFIRM
CONFIRM
08
PRESET TEMPERATURE 1/2 For example: Now time is 8:00 and temperature is
30°C. We set the PRESET TEMP as following table.
PRESET WEATHER ECO The following page will appear:
TEMP. TEMP.SET MODE
09
PRESET TEMPERATURE If the weather TEMP.SET is activated, the desired
temperature can not be adjusted on the
PRESET WEATHER ECO interface.Press the ''▼'' ''▲'' to adjust the
TEMP. TEMP.SET MODE temperature on home page. The following page will
appear:
ZONE1 C-MODE LOW TEMP. OFF
ZONE1 H-MODE LOW TEMP. OFF
ZONE2 C-MODE LOW TEMP. OFF
Weather temp.set function is
ZONE2 H-MODE LOW TEMP. OFF
on. Do you want to turn off it?
ON/OFF
i INFORMATION
WEATHER TEMP. SET have four kinds of NO YES
curves :1.the curve of the high temperature
setting for heating,2.the curve of the low CONFIRM
temperature setting for heating, 3.the curve of
the high temperature setting for cooling ,4.the
curve of the low temperature setting for cooling. Move to “NO”,press “ ” to come back to home
It only uses the curve of the high temperature page,move to “YES”,press “ ” to reset the WEATHER
setting for heating, if the high temperature is set TEMP. SET.
for heating.
It only uses the curve of the low temperature
PRESET TEMPERATURE
setting for heating, if the low temperature is set
for heating.
It only uses the curve of the high temperature PRESET WEATHER ECO
setting for cooling, if the high temperature is set TEMP. TEMP.SET MODE
for cooling.
It only uses the curve of the low temperature ZONE1 C-MODE LOW TEMP OFF
setting for cooling, if the low temperature is set ZONE1 H-MODE LOW TEMP OFF
for cooling.
ZONE2 C-MODE LOW TEMP OFF
See ''FOR SERVICEMAN''> ''COOL MODE
ZONE2 H-MODE LOW TEMP OFF
SETTING'' and > ''HEAT MODE SETTING'' in
"Installation and owner's manual". ON/OFF
10
Use '◄ '' ''►''to scroll .Press ''
following page will appear:
'' to select. The 6.3 Domestic Hot Water(DHW)
DHW mode typically consists of the following :
PRESET TEMPERATURE 1) DISINFECT
2) FAST DHW
PRESET WEATHER ECO 3) TANK HEATER
TEMP. TEMP.SET MODE 4) DHW PUMP
i INFORMATION
ECO MODE SET have two kinds of DOMESTIC HOT WATER(DHW)
curves :1.the curve of the high temperature
setting for heating, 2.the curve of the low DIS- FAST TANK DHW
temperature setting for heating, INFECT DHW HEATER PUMP
It only uses the curve of the high temperature
setting for heating, if the high temperature is set CURRENT STATE OFF
for heating.
OPERATE DAY FRI
It only uses the curve of the low temperature
setting for heating, if the low temperature is set START 23:00
for heating.
See ''FOR SERVICEMAN''>''HEAT MODE ON/OFF
SETTING'' in "Installation and owner's manual".
The desired temperature (T1S) can’t be Use ''◄''、''► '' ''▼ '' ''▲'' to scroll and use ''▼''
adjusted, when the ECO mode is ON. ''▲'' to adjust the parameters when setting ''OPERATE
You can selet the low or hige temperature DAY'' and ''START''. If the OPERATE DAY is set
setting for heating to see the “Table 1~2”. FRIDAY and the START is set 23:00,
the disinfect function will be activated on 23:00 Friday.
If ECO MODE is ON and ECO TIMER is If the disinfect function is running,the following page will
OFF,the unit run ECO mode all the time. appear:
If ECO MODE is ON and ECO TIMER is ON,
the unit run ECO mode according to the start
time and end time.
11
6.3.2 Fast DHW
DOMESTIC HOT WATER(DHW)
The FAST DHW function is used to force the system to
operate in DHW mode. DIS- FAST TANK DHW
The heat pump and the booster heater or addition heater INFECT DHW HEATER PUMP
will operate for DHW mode together, and the DHW
desired temperature will be changed to 60. CURRENT STATE ON
CURRENT STATE ON
ON/OFF
i INFORMATION
If CURRENT STATE is OFF, the FAST DHW is
invalid, and if CURRENT STATE is ON, the i INFORMATION
FAST DHW function is effective.
The FAST DHW function is once effective. If CURRENT STATE is OFF, TANK HEATER is
invalid.
If the T5(sensor of tank) is fault ,tank heater can’t
work.
6.3.3 TANK HEATER
The tank heater function is used to force the tank heater
to heat the water in tank. In the same situation, the 6.3.4 DHW Pump
cooling or heating is required and the heat pump system
is operating for cooling or heating, however there still is The DHW PUMP function is used to return water of the
a demand for the hot water. water net. Go to '' '' > ''DOMESTIC HOT WATER''
Also, even if the heat pump system fails, TANK HEATER > ''DHW PUMP''. Press '' ''. The following page will
can be used to heat water in tank. appear:
12
DOMESTIC HOT WATER(DHW) 1/2 6.4 Schedule
DIS- FAST TANK DHW
INFECT DHW HEATER PUMP SCHEDULE menu contents as follows:
1) TIMER
NO. START NO. START 2) WEEKLY SCHEDULE
3) SCHEDULE CHECK
T1 00:00 T4 00:00 4) CANCEL TIMER
T2 00:00 T5 00:00
T3 00:00 T6 00:00 6.4.1 Timer
If the weekly schedule function is on, the timer is off, the
later setting is effective. If the Timer is activated, is
displayed on home page.
DOMESTIC HOT WATER(DHW) 2/2
SCHEDULE 1/2
DIS- FAST TANK DHW
INFECT DHW HEATER PUMP WEEKLY SCHEDULE CANCEL
TIMER
SCHEDULE CHECK TIMER
NO. START NO. START
T7 00:00 T10 00:00 NO. START END MODE TEMP
Use ''◄ '' ''► '' ''▼'' ''▲'' to scroll and use ''▼''
''▲'' to adjust the time, the mode and the
Use ''◄' ''►'' ''▼'' ''▲'' to scroll and use ''▼'' ''▲''
temperature.
to adjust the parameters.
Move to “■”, press '' '' to select or unselect.(
For example:you have set the parameter about the DHW ....the timer is selected. the timer is unselected.) six
PUMP(See ''FOR SERVICEMAN''>''DHW MODE timers can be set.
SETTING'' on "Installation and owner's manual").
PUMP RUNNING TIME is 30 minutes. If you want to cancel the TIMER, you move the cursor
to “ ”,press “ ”,the become ,the timer is
Set as follows: invalid.
NO. START If you set the start time later than the end time or the
temperature out of range of the mode. The following
1 6:00
page will appear:
2 7:00
3 8:00
SCHEDULE
4 9:00
TIMER WEEKLY SCHEDULE CANCEL
The PUMP will run as follows:
SCHEDULE CHECK TIMER
PUMP
Timer1 is useless.
13
Example: First select the days of the week you wish to schedule.
Use ''◄ '' ''►''to scroll, press '' '' to select or
Six timers is set as following: unselect the day.
“ MON ” means that the day is selected,“MON” means
NO. START END MODE TEMP that the day is unselected.
T1 100 300 DHW 50℃
T2 700 900 HEAT 28℃ i INFORMATION
T3 1130 1300 COOL 20℃ We must set two days at least when we want to
T4 14 00 1600 HEAT 28℃ enable WEEKLY SCHEDULE function.
COOL
HEAT
DHW
DHW
18:00
19:00
23:30
1:00
3:00
7:00
9:00
i INFORMATION
SCHEDULE 2/2
If the start time is same to the end time in one
timer, the timer is invalid. WEEKLY SCHEDULE CANCEL
TIMER
SCHEDULE CHECK TIMER
ENTER CANCEL
MON SELECT
14
6.4.3 Schedule check If TIMER or WEEKLY SCHEDULE is canceled, icon'' ''
schedule check can only check the weekly schedule. or '' '' will disappear on the home page.
7
Go to '' '' > ''SCHEDULE'' >''SCHEDULE' CHECK''.
Press'' ''. The following page will appear:
SCHEDULE
i INFORMATION
You have to reset TIMER/WEEKLY SCHEDULE,
ENTER if you change the WATER FLOW TEMP. to the
ROOM TEMP. or you change the ROOM TEMP.
WEEKLY SCHEDULE CHECK to the WATER FLOW TEMP.
The TIMER or WEEKLY SCHEDULE is invalid, if
DAY NO MODE SET START END ROOM THERMOSTAT is activated.
T1 HEAT 0℃ 00:00 00:00
T2 HEAT 0℃ 00:00 00:00
T3 HEAT 0℃ 00:00 00:00 i INFORMATION
MON
T4 HEAT 0℃ 00:00 00:00
The ECO has the highest priority, the TIMER or
T5 HEAT 0℃ 00:00 00:00 WEEKLY SCHEDULE has the second priority
T6 HEAT 0℃ 00:00 00:00 and the PRESET TEMP. or WEATHER TEMP.
SET has the lowest priority.
The PRESET TEMP. or WEATHER TEMP. SET
Press ''▼'' ''▲'' , the timer from Monday to Sunday will becomes invalid, when we set the ECO valid. We
appear: must reset the PRESET TEMP. or WEATHER
TEMP. SET when we set the ECO invalid.
6.4.4 CANCEL TIMER
TIMER or WEEKLY SCHEDULE is invalid when
Go to '' '' > ''SCHEDULE'' >''CANCEL TIMER''. ECO is valid. TIMER or WEEKLY SCHEDULE is
Press'' ''. The following page will appear: activated when the ECO is not running.
TIMER and WEEKLY SCHEDULE are on the
SCHEDULE same priority. The later setting function is valid.
The PRESET TEMP. becomes invalid when
WEEKLY SCHEDULE CANCEL TIMER or WEEKLY SCHEDULE is valid. The
TIMER WEATHER TEMP. SET is not affected by the
SCHEDULE CHECK TIMER
setting of TIMER or WEEKLY SCHEDULE.
Do you want to cancel the PRSET TEMP. and WATHER TEMP.SET are
timer and weekly schedule? on the same priority. The later setting function is
valid.
NO YES
ENTER
Use ''◄ '' ''► '' ''▼'' ''▲''to move to ”YES”, press
i INFORMATION
" " to cancel timer. If you want to exit CANCEL TIMER, All about the time set items(PRESET TEMP.
press “BACK”. ECO DISINFECT DHW PUMP TIMER
WEEKLY SCHEDULESILENCE MODE
If TIMER or WEEKLY SCHEDULE is activated, timer HOLIDAY HOME), the ON/OFF of the
icon '' '' or weekly schedule icon '' '' will display on corresponding function can be activated from
the home page. 7
the start time to the end time.
6.5 Options
OPTIONS menu contents as following:
1) SILENT MODE
2) HOLIDAY AWAY
3) HOLIDAY HOME
4) BACKUP HEATER
15
6.5.1 Silent Mode You can use ''▼'' ''▲'' to select level 1 or level 2. Press
'' ''.
The SILENT MODE is used to decrease the sound of the
unit. However, it also decreases the heating/cooling If the silent TIMER is selected, Press “ ” to enter, the
capacity of the system. There are two silent mode levels. following page will appear.
level2 is more silent than level1 , and the heating or
cooling capacity is also more decreasing. 2/2
OPTIONS
There are two methods to use the silent mode:
1) silent mode in all time; SILENT HOLIDAY HOLIDAY BACKUP
2) silent mode in timer. MODE AWAY HOME HEATER
Go to the home page to check if silent mode is
activated. If the silent mode is activated,'' '' will TIMER1 OFF
be displayed on the home page.
TIMER2 START 22:00
Go to '' '' > ''OPTIONS'' > ''SILENT MODE''. Press TIMER2 END 07:00
'' '' . The following page will appear:
TIMER2 OFF
ADJUST
OPTIONS 1/2
SILENT HOLIDAY HOLIDAY BACKUP There are two timers for setting. Move to “■”, press ''
MODE AWAY HOME HEATER '' to select or unselect.
If the two time are both unselected,the silent mode will
operate in all time.Otherwise, it will operate according as
CURRENT STATE OFF
the time.
SILENT LEVEL LEVEL 1
TIMER1 START 12:00 6.5.2 Holiday Away
TIMER1 END 15:00 If the holiday away mode is activated, will display
on the home page.
ON/OFF
The holiday away function is used to prevent frozen in
the winter during the outside holiday,and return the unit
Use '' '' to select ON or OFF.
before the end of the holiday.
Description:
Go to '' '' > ''OPTIONS'' > ''HOLIDAY AWAY''.
If CURRENT STATE is OFF, SILENT MODE is invalid.
Press '' '' . The following page will appear:
When you select SILENT LEVEL, and press '' '' or ''►
''. The following page will appear: OPTIONS 1/2
CURRENT STATE ON
SILENT LEVEL LEVEL 2 ADJUST
TIMER1 START 12:00
TIMER1 END 15:00 Usage example: You go away during the winter.The
ADJUST current date is 2018-01-31,two days later is 2018-02-02,
it is the beginning date of the holiday.
LEVEL 2 If you are in the following situation:
In 2 days, you go away for 2 weeks during the winter.
You want to save energy, but prevent your house
from freezing.
16
Then you can do the following: OPTIONS
1) Configure the holiday away the following settings:
2) Activate the holiday mode. SILENT HOLIDAY HOLIDAY BACKUP
Go to '' '' > ''OPTIONS'' > ''HOLIDAY AWAY''. MODE AWAY HOME HEATER
Press '' '' .
Use '' '' to select ''OFF'' or ''ON'' and use '' ◄ ''
CURRENT STATE OFF
''► '' ''▼'' ''▲'' to scroll and adjust.
FROM 00-00-2000
UNTIL 00-00-2000
Setting Value
TIMER ENTER
Holiday away ON
ON/OFF
From 2 February 2018
Until 16 February 2018
Use '' '' to select ''OFF'' or ''ON'' and use ''◄ ''
Operation mode Heating ''► '' ''▼'' ''▲'' to scroll and adjust.
disinfect ON If the CURRENT STATE is OFF, the HOLIDAY HOME is
OFF.
i INFORMATION If the CURRENT STATE is ON, the HOLIDAY HOME is
ON.
If DHW mode in holiday away mode is ON,
Use ''▼'' ''▲'' to adjust the date.
The disinfect set by user is invalid.
Before and after your holiday, your normal schedule
If holiday away mode is ON, The timer and
will be used.
weekly schedule are invalid except exit.
During your holiday, you save energy and prevent your
If the CURRENT STATE is OFF,the HOLIDAY
house from freezing.
AWAY is OFF.
If the CURRENT STATE is ON,the HOLIDAY i INFORMATION
AWAY is ON.
You have to exit Holiday away or Holiday
Disinfecting the unit on 23:00 of the last day if
home, if you change the operation mode of the
disinfect is ON.
unit.
When in holiday away mode, the climate
related curves previously set is invalid, and the
curves will automatically take effect after the
holiday away mode is ends.
6.5.4 Backup Heater
The preset temperature is invalid when in The BACKUP HEATER function is used to force the
holiday away mode, but the preset value still backup heater. Go to '' '' > ''OPTIONS'' >
display on the main page. ''BACKUP HEATER''. Press '' '' . If IBH and AHS is set
invalid by DIP switch on the main control board of
hydraulic module , The following page will appear:
6.5.3 Holiday Home OPTIONS
The holiday home function is used to deviate from the
normal schedules without having to change them during SILENT HOLIDAY HOLIDAY BACKUP
the holiday at home. MODE AWAY HOME HEATER
Period Then...
Before and after your Your normal schedules
holiday will be used.
The configured holiday IBH=Indoor unit backup heater.
During your holiday
settings will be used. AHS=Additional heating source.
If IBH and AHS is set valid by DIP switch on the main
If the holiday home mode is activated, will display on control board of hydraulic module, The following page
the home page. will appear:
Go to '' '' > ''OPTIONS'' > ''HOLIDAY HOME''.
Press '' '' . The following page will appear: OPTIONS
BACKUP HEATER ON
ON/OFF
17
Use '' '' to select ''OFF'' or ''ON'' . The cool/heat mode can't turn on or off when the
COOL/HEAT MODE ON/OFF is locked.If you want to
turn on or off the cool/heat mode when COOL/HEAT MODE
i INFORMATION ON/OFF is locked,the following page will appear:
1 2 3
DHW temperature adjust function
is locked.
Do you want to unlock?
ENTER ADJUST
CHILD LOCK
The DHW mode can't turn on or off when the
COOL/HEAT TEMP. ADJUST UNLOCK DHW MODE ON/OFF is locked.If you want to turn
COOL/HEAT MODE ON/OFF UNLOCK on or off the DHW mode when DHW MODE
DHW TEMP. ADJUST UNLOCK ON/OFF is locked,the following page will appear:
DHW MODE ON/OFF UNLOCK
18
The service call can show the service phone or mobile SERVICE INFORMATION 1/2
nember.The installer can input the phone number.See
''FOR SERVICEMAN''. SERVICE ERROR
PARAMETER DISPLAY
CALL CODE
SERVICE INFORMATION
ROOM SET TEMP. 26℃
SERVICE ERROR MAIN SET TEMP. 55℃
CALL CODE PARAMETER DISPLAY
TANK SET TEMP. 55℃
PHONE NO. ******************
ROOM ACTUAL TEMP. 24℃
MOBILE NO. ******************
SERVICE ERROR
PARAMETER DISPLAY
Error code is used to show when the fault or proction CALL CODE
happen and show the mean of the error code.
MAIN ACTUAL TEMP. 26℃
SERVICE INFORMATION TANK ACTUAL TEMP. 55℃
ON/OFF
E2 comunication fault between Use '' '' to enter and use ''◄ '' ''► '' ''▼ '' ''▲'' to
controller and indoor unit scroll.
i INFORMATION Press '' ''. There are nine pages for the operating
parameter as following. Use ''▼ '' ''▲'' to scroll.
A total of eight fault codes can be recorded.
Press"►" and "◄" to check slave units' operation parameter
in cascade system. The address code in the upper right corner
will change from "#00" to "#01""#02" etc. accordingly.
The parameter function is used to display the main
parameter, there are two pages to show the parameter:
19
OPERATION PARAMETER #00 OPERATION PARAMETER #00
ONLINE UNITS NUMBER 1 FAN SPEED 600R/MIN
OPERATE MODE COOL IDU TARGET FREQUENCY 46Hz
SV1 STATE ON FREQUENCY LIMITED TYPE 5
SV2 STATE OFF SUPPLY VOLTAGE 230V
SV3 STATE OFF DC GENERATRIX VOLTAGE 420V
PUMP_I ON DC GENERATRIX CURRENT 18A
ADDRESS 1/9 ADDRESS 7/9
OPERATION PARAMETER #00 OPERATION PARAMETER #00
PUMP_O OFF TW_O PLATE W-OUTLET TEMP. 35°C
PUMP_C OFF TW_I PLATE W-INLET TEMP. 30°C
PUMP_S OFF T2 PLATE F-OUT TEMP. 35°C
PUMP_D OFF T2B PLATE F-IN TEMP. 35°C
PIPE BACKUP HEATER OFF Th COMP. SUCTION TEMP. 5°C
TANK BACKUP HEATER ON Tp COMP. DISCHARGE TEMP. 75°C
ADDRESS 2/9 ADDRESS 8/9
20
The FOR SERVICEMAN is used for installer or service Use ''◄'' '' ►'' to move to"YES", press " " to select AP mode.
engineer. It is NOT instended the home owener alters Select AP Mode correspondingly on the mobile device and
setting with this menu. continue the follow-up settings according to the APP prompts.
It is for this reason password protection is requierd to
prevent unauthorised access to the service settings.
CAUTION
The password is 234. After enter Ap mode, if it’s not connected with mobile
phone, the LCD icon " " will flash 10 minutes then
6.9.3 How To Exit For SERVICEMAN disappear.
If it’s connected with the mobile phone, the icon " "
If you have set all the parameter.
will be constantly display.
Press '' '', the following page will appear
6.10 Network Configuration Guidelines Use ''◄'' ''►'' to move to "YES", press ” ” to restore
WLAN setting.Complete the above operation and wireless
The wired controller realizes intelligent control with a built-in configuration is reset.
module, which receives control signal from the APP. AP Mode connecting WLAN:
Before connecting the WLAN, please check for it if the router in
your environment is active and make sure that the wired 6.11 SN VIEW
controller is well-connected to the wireless signal.
During the Wireless distribution process, the LCD icon “ ”
flashes to indicate that the network is being deployed. After the
process is completed, the icon “ ” will be constantly on. SN VIEW
WLAN SETTING
AP MODE
RESTORE WLAN SETTING
SN VIEW #1
IDU NO.
ENTER ********************************
AP MODE
NO YES
CONFIRM
21
7 MENU STRUCTURE : OVERVIEW
MENU OPERATION MODE
OPERATION MODE HEAT
COOL
PRESET TEMPERATURE AUTO
DOMESTIC HOT WATER(DHW)
SCHEDULE
OPTIONS PRESET TEMPERATURE
PRESET TEMP.
CHILD LOCK WEATHER TEMP. SET
SERVICE INFORMATION ECO MODE
OPERATION PARAMETER
FOR SERVICEMAN
WLAN SETTING
DOMESTIC HOT WATER(DHW)
SN VIEW DISINFECT
ENERGY METERING FAST DHW DISINFECT
TANK HEATER CURRENT STATE
DHW PUMP OPERATE DAY
START
SCHEDULE
TIMER
WEEKLY SCHEDULE
SCHEDULE CHECK
CANCEL TIMER
HOLIDAY AWAY
CURRENT STATE
CHILD LOCK
DHW MODE
COOL/HEAT TEMP. ADJUST
DISINFECT
COOL/HEAT MODE ON/OFF
HEAT MODE
DHW TEMP. ADJUST
FROM
DHW MODE ON/OFF
UNTIL
OPERATION PARAMETER
FOR SERVICEMAN
DHW MODE SETTING DISPLAY
COOL MODE SETTING TIME
HEAT MODE SETTING DATE
AUTO MODE SETTING LANGUAGE
TEMP. TYPE SETTING BACKLIGHT
ROOM THERMOSTAT BUZZER
OTHER HEATING SOURCE SCREEN LOCK TIME
HOLIDAY AWAY SETTING SMART GRID RUNNING TIME
SERVICE CALL
RESTORE FACTORY SETTINGS
TEST RUN
SPECIAL FUNCTION
AUTO RESTART
POWER INPUT LIMITATION SN VIEW
INPUT DEFINE HMI
CASCADE SET IDU
HMI ADDRESS SET ODU
22
FOR SERVICEMAN 1 DHW MODE SETTING
1 DHW MODE SETTING 1.1 DHW MODE
2 COOL MODE SETTING 2 COOL MODE SETTING
1.2 DISINFECT
3 HEAT MODE SETTING 2.1 COOL MODE
1.3 DHW PRIORITY
4 AUTO MODE SETTING 2.2 t_T4_FRESH_C
1.4 PUMP_D
5 TEMP. TYPE SETTING 2.3 T4CMAX
1.5 DHW PRIORITY TIME SET
6 ROOM THERMOSTAT 2.4 T4CMIN
1.6 dT5_ON
7 OTHER HEATING SOURECE 2.5 dT1SC
1.7 dT1S5
8 HOLIDAY AWAY SETTING 2.6 dTSC
1.8 T4DHWMAX
9 SERVICE CALL 2.7 t_INTERVAL_C
1.9 T4DHWMIN
10 RESTORE FACTORY SETTINGS 2.8 T1SetC1
1.10 t_INTERVAL_DHW
11TEST RUN 2.9 T1SetC2
1.11 dT5_TBH_OFF
12 SPECIAL FUNCTION 2.10 T4C1
1.12 T4_TBH_ON
13 AUTO RESTART 2.11 T4C2
1.13 t_TBH_DELAY
14 POWER INPUT LIMI 2.12 ZONE1 C-EMISSION
1.14 T5S_DISINFECT
TATION 2.13 ZONE2 C-EMISSION
1.15 t_DI_HIGHTEMP
15 INPUT DEFINE 1.16 t_DI_MAX
16 CASCADE SET 4 AUTO MODE SETTING 1.17 t_DHWHP_RESTRICT
17 HMI ADDRESS SET 4.1 T4AUTOCMIN 1.18 t_DHWHP_MAX
4.2 T4AUTOHMAX 1.19 PUMP_D TIMER
1.20 PUMP_D RUNNING TIME
5 TEMP. TYPE SETTING 1.21 PUMP_D DISINFECT RUN
5.1 WATER FLOW TEMP.
5.2 ROOM TEMP. 3 HEAT MODE SETTING
5.3 DOUBLE ZONE 3.1 HEAT MODE
5.4 ENERGY METERING 3.2 t_T4_FRESH_H
3.3 T4HMAX
3.4 T4HMIN
6 ROOM THERMOSTAT 3.5 dT1SH
6.1ROOM THERMOSTAT 3.6 dTSH
3.7 t_INTERVAL_H
7 OTHER HEATING SOURCE 3.8 T1SetH1
7.1 dT1_IBH_ON 3.9 T1SetH2
7.2 t_IBH_DELAY 3.10 T4H1
7.3 T4_IBH_ON 3.11 T4H2
7.4 dT1_AHS_ON 3.12 ZONE1 H-EMISSION
7.5 t_AHS_DELAY 3.13 ZONE2 H-EMISSION
7.6 T4_AHS_ON 3.14 t_DELAY_PUMP
7.7 IBH LOCATE
7.8 P_IBH1
7.9 P_IBH2
7.10 P_TBH
9 SERVICE CALL
PHONE NO.
MOBILE NO.
11 TEST RUN
12 SPECIAL FUNCTION
13 AUTO RESTART
13.1 COOL/HEAT MODE
13.2 DHW MODE
14 POWER INPUT LIMITATION 16 CASCADE SET
14.1 POWER LIMITATION 16.1 PER_START
16.2 TIME_ADJUST
15 INPUT DEFINE(M1M2) 16.3 ADDRESS RESET
15.1 M1M2
15.2 SMART GRID
15.3 Tw2 17 HMI ADDRESS SET
15.4 Tbt1 17.1 HMI SET
15.5 Tbt2 17.2 HMI ADDRESS FOR BMS
15.6 Ta 17.3 STOP BIT
15.7 Ta-adj
15.8 SOLAR INPUT
15.9 F-PIPE LENGTH
15.10 RT/Ta_PCB
15.11 PUMP_I SILENT MODE
15.12 DFT1/DFT2
23
Table1 The environment temperature curve of the low temperature setting for heating
T4 ≤ - 20 - 19 - 18 - 17 - 16 - 15 - 14 - 13 - 12 - 11 - 10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0
1- T1S 38 38 38 38 38 37 37 37 37 37 37 36 36 36 36 36 36 35 35 35 35
2- T1S 37 37 37 37 37 36 36 36 36 36 36 35 35 35 35 35 35 34 34 34 34
3- T1S 36 36 36 35 35 35 35 35 35 34 34 34 34 34 34 33 33 33 33 33 33
4- T1S 35 35 35 34 34 34 34 34 34 33 33 33 33 33 33 32 32 32 32 32 32
5- T1S 34 34 34 33 33 33 33 33 33 32 32 32 32 32 32 31 31 31 31 31 31
6- T1S 32 32 32 32 31 31 31 31 31 31 31 31 30 30 30 30 30 30 30 30 29
7- T1S 31 31 31 31 30 30 30 30 30 30 30 30 29 29 29 29 29 29 29 29 28
8- T1S 29 29 29 29 28 28 28 28 28 28 28 28 27 27 27 27 27 27 27 27 26
T4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 ≥ 20
1- T1S 35 35 34 34 34 34 34 34 33 33 33 33 33 33 32 32 32 32 32 32 32
2- T1S 34 34 33 33 33 33 33 33 32 32 32 32 32 32 31 31 31 31 31 31 31
3- T1S 32 32 32 32 32 32 31 31 31 31 31 31 30 30 30 30 30 30 29 29 29
4- T1S 31 31 31 31 31 31 30 30 30 30 30 30 29 29 29 29 29 29 28 28 28
5- T1S 30 30 30 30 30 30 29 29 29 29 29 29 28 28 28 28 28 28 27 27 27
6- T1S 29 29 29 29 29 29 28 28 28 28 28 28 27 27 27 27 27 27 26 26 26
7- T1S 28 28 28 28 28 28 27 27 27 27 27 27 26 26 26 26 26 26 25 25 25
8- T1S 26 26 26 26 26 26 26 25 25 25 25 25 25 25 25 24 24 24 24 24 24
Table2 The environment temperature curve of the high temperature setting for heating
T4 ≤ - 20 - 19 - 18 - 17 - 16 - 15 - 14 - 13 - 12 - 11 - 10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0
1- T1S 55 55 55 55 54 54 54 54 54 54 54 54 53 53 53 53 53 53 53 53 52
2- T1S 53 53 53 53 52 52 52 52 52 52 52 52 51 51 51 51 51 51 51 51 50
3- T1S 52 52 52 52 51 51 51 51 51 51 51 51 50 50 50 50 50 50 50 50 49
4- T1S 50 50 50 50 49 49 49 49 49 49 49 49 48 48 48 48 48 48 48 48 47
5- T1S 48 48 48 48 47 47 47 47 47 47 47 47 46 46 46 46 46 46 46 46 45
6- T1S 45 45 45 45 44 44 44 44 44 44 44 44 43 43 43 43 43 43 43 43 42
7- T1S 43 43 43 43 42 42 42 42 42 42 42 42 41 41 41 41 41 41 41 41 40
8- T1S 40 40 40 40 39 39 39 39 39 39 39 39 38 38 38 38 38 38 38 38 37
T4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 ≥ 20
1- T1S 52 52 52 52 52 52 52 51 51 51 51 51 51 51 51 50 50 50 50 50 50
2- T1S 50 50 50 50 50 50 50 49 49 49 49 49 49 49 49 48 48 48 48 48 48
3- T1S 49 49 49 49 49 49 49 48 48 48 48 48 48 48 48 47 47 47 47 47 47
4- T1S 47 47 47 47 47 47 47 46 46 46 46 46 46 46 46 45 45 45 45 45 45
5- T1S 45 45 45 45 45 45 45 44 44 44 44 44 44 44 44 43 43 43 43 43 43
6- T1S 42 42 42 42 42 42 42 41 41 41 41 41 41 41 41 40 40 40 40 40 40
7- T1S 40 40 40 40 40 40 40 39 39 39 39 39 39 39 39 38 38 38 38 38 38
8- T1S 37 37 37 37 37 37 37 36 36 36 36 36 36 36 36 35 35 35 35 35 35
24
The automatic setting curve
The automatic setting curve is the ninth curve,this is the calculation:
T1S (T1S2)
T1SETH 1
T1SETH 2
T4
T4H1 T4H 2
State:In the setting the wired controller, if T4H2<T4H1, then exchange their value; if T1SETH1<T1SETH2, then
exchange their value.
Table3 The environment temperature curve of the low temperature setting for cooling
25
Table4 The environment temperature curve of the high temperature setting for cooling
T1S (T1S2)
T1SETC1
T1SETC 2
T4
T4C1 T4C2
State: In the setting the wired controller, if T4C2<T4C1, then exchange their value; if T1SETC1<T1SETC2, then
exchange their value.
26
NOTE B.13.5.2�
İSTANBUL : GOSB - Gebze Org. San. Bölgesi, Ş. Bilgisu Cad. 41480 Gebze-KOCAELİ
Tel: (0262) 648 60 00 - Fax: (0262) 648 60 08
ANKARA : Sedat Simavi Sok. No: 48, 06550 Çankaya - ANKARA
Tel: (0312) 409 52 00 - Fax: (0312) 440 79 30
İZMİR : Şehit Fethibey Cad. No:55, Kat:13, 35210 Pasaport - İZMİR
Tel: (0232) 483 25 60 - Fax: (0232) 441 55 13
ADANA : Ziyapaşa Bulvarı Çelik Ap. No : 25/5-6, 01130 ADANA
Tel: (0322) 457 62 23 - Fax: (0322) 453 05 84
ANTALYA : Mehmetçik Mahallesi Aspendos Bulvarı No: 79/5 - ANTALYA
web: www.alarko-carrier.com.tr
Tel: (0242) 322 00 29 - Fax: (0242) 322 87 66
MDH : 444 0 128 e-posta: [email protected]