Product datasheet
Specifications
REL52120 discontinued. To order it,
click on blue Product Selector
button, configure P3U30, and use its
output xml file
REL52120
notification_critical_stroke Discontinued on: Mar 12, 2024 AD
notification_critical_stroke Discontinued
Main
Range of product Easergy P3
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Product or component type Protection relay
Relay application Feeder
product reference P3F30-DGIIA-AAENA-BAAAA
power supply 24...48 V DC
measuring inputs : 1/5 A CT phase current 3
: 5/1 A CT residual current 1
: 1/0.2 A CT residual current 1
: 100 V/110 V VT voltage 4
number of Digital Inputs (DI) 26
number of Digital Outputs (DO) 1 watchdog
9
number of analogue outputs 0
communication ports USB port 1 front
RJ45 2 rear
communication protocols IEC 61850 ed. 1
IEC 61850 ed. 2
IEC 60870-5-101
DNP3 TCP
Modbus TCP
EtherNet/IP
Modbus RTU
DeviceNet
Profibus DP
SPAbus
RSTP redundancy protocol
PRP redundancy protocol
Redundancy communication port RSTP
protocol PRP
Cybersecurity Port hardening
Password protection
May 24, 2025 1
AD
protection functions Phase overcurrent 50/51
Directional phase overcurrent 67
Earth fault overcurrent 50N/51N
Directional earth fault 67N
Transient earth fault 67NI
Capacitor bank unbalance 51C
Broken conductor 46 I2/I1
Cold load pick-up
Switch ON to fault (SOTF)
Breaker failure 50BF
Directional active underpower 37P
Fault locator 21FL
Recloser 79
Phase undercurrent 37
Excessive starting time, locked rotor 48/51LR
Motor restart inhibition 66
Capacitor overvoltage 59C
Negative sequence overcurrent 46
Overvoltage 59
Undervoltage 27
Positive sequence undervoltage 27P
Earth fault overvoltage 59N
Underfrequency 81/81N
Rate of change of frequency 81R
Synchro-check 25
Lockout relay 86
CT supervision 60
VT supervision 60
H2 detection 68H2
H5 detection 68H5
H2 detection
Programmable stages 99
Programmable curve
H5 detection
Arc flash protection No
measurement functions Current 3-phase
Current zero sequence
Current positive sequence
Current negative sequence
Current ratio of negative and positive
Voltage phase to earth
Voltage phase to phase
Voltage zero sequence
Voltage positive sequence
Voltage negative sequence
Voltage ratio of negative and positive
Short circuit fault reactance
Fault location current
Earth fault reactance
Frequency
Active power
RMS active power
Reactive power
RMS reactive power
Apparent power
RMS apparent power
Active energy
Reactive energy
Cos φ
Tan φ
Power angle
Power factor
Voltage phasor diagram view
Current phasor diagram view
Current 2nd, 15th harmonics with THD
Voltage 2nd, 15th harmonics with THD
Voltage interruption
Condition monitoring CB wear
2 May 24, 2025
AD
control functions Switchgear control and monitoring
Programmable switchgear interlocking
Local control on single-line diagram
Local control with I/O keys
Local/remote control
2 function keys
Mobile application with Easergy SmartApp
Web-server
Programmable logic
controllable switchgear devices 6 controlled + 8 displayed
number of setting groups 4
monitoring functions Trip circuit supervision 74
Circuit breaker monitoring
Relay self-monitoring
logs and records Event recording
Disturbance recording
Tripping context
Switchgear diagnosis type CT/VT supervision ANSI code: 60
CT supervision
Trip circuit supervision ANSI code: TCS
Connections - terminals Screw removable (digital input/output)
Pin fixed (current transformer)
Pin removable (voltage transformer)
Complementary
Operating threshold 24...230 V AC/DC
Time synchronisation protocol SNTP
Software name EcoStruxure Power Device
ESetup Easergy Pro
Web server Embedded HTTP server
Display type LCD 128 x 128 pixels with single line diagram
Number of key 2 customizable
Local signalling 2 LEDs
16 LEDs programmable
Standards IEC
Height 176 mm
Width 270 mm
Depth 230 mm
Net weight 4.2 kg maximum
Environment
climatic withstand Exposure to dry heat Bb tests conforming to EN/IEC 60068-2-2
Exposure to cold Ad tests conforming to EN/IEC 60068-2-1
Exposure to damp heat in service Db tests conforming to EN/IEC 60068-2-30
Exposure to damp heat in service Cab tests conforming to EN/IEC 60068-2-78
Mechanical robustness Vibrations (level: class II) conforming to IEC 60255-21-1
Vibrations: Fc conforming to IEC 60068-2-6
Shocks (level: class II) conforming to IEC 60255-21-2
Shocks: Ea conforming to IEC 60068-2-27
Seismic tests method A (level: class II) conforming to IEC 60255-21-3
Bumps (level: class II) conforming to IEC 60255-21-2
Bumps: Ea conforming to IEC 60068-2-27
May 24, 2025 3
AD
Electromagnetic compatibility Emission tests conforming to IEC/EN 60255-26 ed. 3
Emission tests class A conforming to CISPR 11
Emission tests class A conforming to CISPR 22
EMC immunity conforming to IEC/EN 60255-26 ed. 3
EMC immunity conforming to EN/IEC 61000-4-18
EMC immunity level 4 conforming to EN/IEC 61000-4-2
EMC immunity level 3 conforming to EN/IEC 61000-4-3
EMC immunity level 4 conforming to EN/IEC 61000-4-4
EMC immunity level 3 conforming to EN/IEC 61000-4-5
EMC immunity level 3 conforming to EN/IEC 61000-4-6
EMC immunity conforming to EN/IEC 61000-4-8
EMC immunity level 5 conforming to EN/IEC 61000-4-9
EMC immunity conforming to EN/IEC 61000-4-29
EMC immunity conforming to EN/IEC 61000-4-11
EMC immunity conforming to EN/IEC 61000-4-17
Ambient air temperature for -40…65 °C
operation
maximum operating altitude 2000 m
Protective treatment Conformal coating
Relative humidity 0…95 %, without condensation
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 26 cm
Package 1 Width 21 cm
Package 1 Length 31.5 cm
Package 1 Weight 5.2 kg
Contractual warranty
Warranty Up to 10 years extended warranty (Standard warranty 2 years. Please check with
your local SE representative for extended warranty availability and conditions)
4 May 24, 2025
AD
Environmental Data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity
via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Environmental Data explained
How we assess product sustainability
Environmental footprint
Environmental Disclosure Product Environmental Profile
Use Better
Materials and Substances
Pro-active compliance (Product out of EU RoHS legal
EU RoHS Directive
scope)
Use Again
Repack and remanufacture
Circularity Profile End of Life Information
The product must be disposed on European Union
WEEE markets following specific waste collection and never end
up in rubbish bins
May 24, 2025 5
AD
Product datasheet REL52120
Connections and Schema
Functional View
6 May 24, 2025
AD
Product datasheet REL52120
Dimensions Drawings
Base Unit Dimensions
May 24, 2025 7
AD