0% found this document useful (0 votes)
13 views7 pages

Schneider Electric - PowerLogic-P3 - REL52107

The PowerLogic P3F30 is a protection relay designed for feeder applications, operating on a power supply of 48...230 V AC/DC. It features 22 digital inputs, 13 digital outputs, and supports multiple communication protocols including IEC 61850 and Modbus TCP. The product was discontinued on August 3, 2023, and has a maximum operating altitude of 2000 m with an IP54 protection rating.

Uploaded by

sevn2010
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views7 pages

Schneider Electric - PowerLogic-P3 - REL52107

The PowerLogic P3F30 is a protection relay designed for feeder applications, operating on a power supply of 48...230 V AC/DC. It features 22 digital inputs, 13 digital outputs, and supports multiple communication protocols including IEC 61850 and Modbus TCP. The product was discontinued on August 3, 2023, and has a maximum operating altitude of 2000 m with an IP54 protection rating.

Uploaded by

sevn2010
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

Product datasheet

Specifications

PowerLogic P3F30 110-230V


DI110V 22DI 13DO 3CT 4VT 2Io
2LC 110V
REL52107

notification_critical_stroke Discontinued on: 3 Aug 2023

notification_critical_stroke Discontinued EAN Code: 3606481357380

Main
Range of product PowerLogic P3

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Product or component type Protection relay

Relay application Feeder

product reference P3F30-CGGIA-AAEOA-BBAAA

Mounting case size 30TE

power supply 48...230 V AC/DC

measuring inputs : 1/5 A CT phase current 3


: 5/1 A CT residual current 1
: 1/0.2 A CT residual current 1
: 100 V/110 V VT voltage 4

Number of sensors 0 temperature sensor(s)


0 arc sensor(s)

number of Digital Inputs (DI) 22

number of analogue inputs 0

number of Digital Outputs (DO) 1 watchdog


13

number of analogue outputs 0

communication ports USB port 1 front


LC 2 rear

communication protocols IEC 61850 ed. 1


IEC 61850 ed. 2
IEC 60870-5-101
DNP3 TCP
Modbus TCP
EtherNet/IP

Redundancy communication port RSTP


protocol PRP

Cybersecurity Port hardening


Password protection

24 May 2025 1
protection functions Phase overcurrent 50/51
Directional phase overcurrent 67
Earth fault overcurrent 50N/51N
Directional earth fault 67N
Transient earth fault 67NI
Capacitor bank unbalance 51C
Broken conductor 46 I2/I1
Cold load pick-up
Switch ON to fault (SOTF)
Breaker failure 50BF
Directional active underpower 37P
Fault locator 21FL
Recloser 79
Phase undercurrent 37
Excessive starting time, locked rotor 48/51LR
Motor restart inhibition 66
Capacitor overvoltage 59C
Negative sequence overcurrent 46
Overvoltage 59
Undervoltage 27
Positive sequence undervoltage 27P
Earth fault overvoltage 59N
Underfrequency 81/81N
Rate of change of frequency 81R
Synchro-check 25
Lockout relay 86
CT supervision 60
VT supervision 60
H2 detection 68H2
H2 detection
H5 detection 68H5
Programmable stages 99
Programmable curve
H5 detection

Arc flash protection No

measurement functions Current 3-phase


Current zero sequence
Current positive sequence
Current negative sequence
Current ratio of negative and positive
Voltage phase to earth
Voltage phase to phase
Voltage zero sequence
Voltage positive sequence
Voltage negative sequence
Voltage ratio of negative and positive
Short circuit fault reactance
Fault location current
Earth fault reactance
Frequency
Active power
RMS active power
Reactive power
RMS reactive power
Apparent power
RMS apparent power
Active energy
Reactive energy
Cos φ
Tan φ
Power angle
Power factor
Voltage phasor diagram view
Current phasor diagram view
Current 2nd, 15th harmonics with THD
Voltage 2nd, 15th harmonics with THD
Voltage interruption
Condition monitoring CB wear

2 24 May 2025
control functions Switchgear control and monitoring
Programmable switchgear interlocking
Local control on single-line diagram
Local control with I/O keys
Local/remote control
2 function keys
Mobile application with Easergy SmartApp
Web-server
Programmable logic

controllable switchgear devices 6 controlled + 8 displayed

number of setting groups 4

monitoring functions Trip circuit supervision 74


Circuit breaker monitoring
Relay self-monitoring

logs and records Event recording


Disturbance recording
Tripping context

Switchgear diagnosis type CT/VT supervision ANSI code: 60


CT supervision
Trip circuit supervision ANSI code: TCS

Connections - terminals Screw removable (digital input/output)


Pin fixed (current transformer)
Pin removable (voltage transformer)

Complementary
Operating threshold 110...230 V AC/DC

Time synchronisation protocol SNTP

Software name EcoStruxure Power Device


ESetup Easergy Pro

Web server Embedded HTTP server

Display type LCD 128 x 128 pixels with single line diagram

Number of key 2 customizable

Local signalling 2 LEDs


16 LEDs programmable

Standards IEC

Height 176 mm

Width 270 mm

Depth 230 mm

Net weight 4.2 kg maximum

Environment
climatic withstand Exposure to dry heat Bb tests conforming to EN/IEC 60068-2-2
Exposure to cold Ad tests conforming to EN/IEC 60068-2-1
Exposure to damp heat in service Db tests conforming to EN/IEC 60068-2-30
Exposure to damp heat in service Cab tests conforming to EN/IEC 60068-2-78

Mechanical robustness Vibrations (level: class II) conforming to IEC 60255-21-1


Vibrations: Fc conforming to IEC 60068-2-6
Shocks (level: class II) conforming to IEC 60255-21-2
Shocks: Ea conforming to IEC 60068-2-27
Seismic tests method A (level: class II) conforming to IEC 60255-21-3
Bumps (level: class II) conforming to IEC 60255-21-2
Bumps: Ea conforming to IEC 60068-2-27

24 May 2025 3
Electromagnetic compatibility Emission tests conforming to IEC/EN 60255-26 ed. 3
Emission tests conforming to CISPR 11
Emission tests conforming to CISPR 22
EMC immunity conforming to IEC/EN 60255-26 ed. 3
EMC immunity conforming to EN/IEC 61000-4-18
EMC immunity level 4 conforming to EN/IEC 61000-4-2
EMC immunity level 3 conforming to EN/IEC 61000-4-3
EMC immunity level 4 conforming to EN/IEC 61000-4-4
EMC immunity level 3 conforming to EN/IEC 61000-4-5
EMC immunity level 3 conforming to EN/IEC 61000-4-6
EMC immunity conforming to EN/IEC 61000-4-8
EMC immunity level 5 conforming to EN/IEC 61000-4-9
EMC immunity conforming to EN/IEC 61000-4-29
EMC immunity conforming to EN/IEC 61000-4-11
EMC immunity conforming to EN/IEC 61000-4-17

Ambient air temperature for -40…65 °C


operation
IP degree of protection IP54 conforming to IEC 60529

maximum operating altitude 2000 m

Protective treatment Conformal coating

Relative humidity 0…95 %, without condensation

Packing Units
Unit Type of Package 1 PCE

Number of Units in Package 1 1

Package 1 Height 26 cm

Package 1 Width 21 cm

Package 1 Length 31.5 cm

Package 1 Weight 5.2 kg

Contractual warranty
Warranty Up to 10 years extended warranty (Standard warranty 2 years. Please check with
your local SE representative for extended warranty availability and conditions)

4 24 May 2025
Environmental Data

Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity
via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.

Environmental Data explained

How we assess product sustainability

Environmental footprint

Environmental Disclosure Product Environmental Profile

Use Better

Materials and Substances

Pro-active compliance (Product out of EU RoHS legal


EU RoHS Directive
scope)

Use Again

Repack and remanufacture

Circularity Profile End of Life Information

The product must be disposed on European Union


WEEE markets following specific waste collection and never end
up in rubbish bins

24 May 2025 5
Product datasheet REL52107

Connections and Schema

Functional View

6 24 May 2025
Product datasheet REL52107

Dimensions Drawings

Base Unit Dimensions

24 May 2025 7

You might also like