Guia Seleccion Kinetix Motion Contro 2
Guia Seleccion Kinetix Motion Contro 2
Because of the variety of uses for the products described in this publication, those responsible for the application and use of
this control equipment must satisfy themselves that all necessary steps have been taken to ensure that each application and
use meets all performance and safety requirements, including any applicable laws, regulations, codes, and standards.
Reproduction of the contents of this copyrighted publication, in whole or in part, without written permission of
Rockwell Automation, is prohibited.
Chapter 8 Added footnote to the typical configuration figure noting the Kinetix 300/rotary motor 5000 rpm 340
maximum speed limitation.
Revised 2090-Series Motor/Actuator Cables Overview to include cable configuration illustrations and
Chapter 12 397
feature descriptions.
For rotary motors rated with a maximum speed that exceeds 5000 rpm, the maximum speed for
Chapter 13 597
Kinetix 300 drive/motor combinations was reduced to 5000 rpm.
Notes:
With Kinetix Integrated Motion, you’ll benefit from the seamless integration of Allen-Bradley Logix controllers
(ControlLogix and CompactLogix), high-performance networks (EtherNet/IP and SERCOS), and a broad range of
Allen-Bradley AC and servo drives, linear and rotary motors, and linear actuator options. RSLogix 5000 software offers an
extensive set of advanced motion tools for programming, configuration, commissioning, diagnostics, and maintenance
support. Catalog number driven configuration makes motion system commissioning fast and simple, and an extensive
library of motion instructions provide the right functionality for any application.
Kinetix Integrated Motion offers a variety of servo drive, motor, and actuator families for single-axis and multi-axis
applications. These systems offer:
• servo drive power ranges from 0.5…149 kW.
• a choice of SERCOS interface or EtherNet/IP networks.
• a wide range of rotary motors, rotary direct drive motors, linear motors, and linear actuators/stages. Motors offer
continuous torque as low as 0.10 N•m (0.85 lb•in) and up to 955 N•m (8452 lb•in). Linear actuators offer peak
forces of up to 14,679 N (3300 lb).
• Smart Motor Technology provides automatic motor identification for fast, easy configuration and commissioning.
• use of a single software package, RSLogix 5000, for complete support of drive configuration, programming,
commissioning, diagnostics and maintenance.
• powerful on-line motion tools including real-time data trending, graphical PCAM and TCAM profile editor, auto
and manual drive tuning, and advanced drive diagnostics.
• Automatic Device Replacement (ADR) plug-and-run drive/motor/actuator support.
• Motion Analyzer software for comprehensive motion-application sizing and analysis, optimization, selection, and
validation of your Kinetix motion control system.
Part of Rockwell Automation's Machine Solutions offering, Connected Components is a preferred control solution for
machine builders who provide stand-alone machines at low cost. Connected Components provides just enough control to
meet machine and end-user requirements while helping to improve operating efficiencies. Engineering and application tool
sets allow easy design and installation with preferred interoperability of the broad range of component-class products.
The Kinetix 3 component servo drive provides a motion control solution for machine builders producing low-cost
equipment at high volumes. The component servo drive can apply the appropriate level of control for the application
without the added complexity. Systems can include serial commands from MicroLogix controllers or discrete wiring
directly to the sensor or controller with TL-Series low-inertia motors.
Motion Analyzer software facilitates the machine design and investigation process by making it fast, simple, and accurate.
Motion Analyzer software offers a fact-based decision path and design optimization approach that enables machine
builders to:
• reduce motion system design risk.
• reduce time from machine design to shipment.
• optimize motion control system cost and size.
• enhance machine performance and reliability.
• create a bill of materials.
Motion Analyzer software includes the full range of Kinetix Motion Control products and features:
MP-Series Electric Cylinders - deliver off-the-shelf linear motion without the need to search through catalogs looking for
suitable ballscrews, timing belts, pulleys, and bearings. No mechanical data to enter, just input load information and move
profile. Output even includes an L10 life estimate.
Tuning simulation - is a tool to help predict how your machine will perform under real-world conditions. Emulates tuning
an axis in RSLogix 5000 software (including Auto-tune) and then simulates the behavior of the load, motor, and drive.
Factors-in the mechanical compliance or backlash to give a realistic simulation.
Torque Feedback %
RMS = 48.4%
Efficiency analysis - provides an understanding of where the torque produced by the motor is consumed.
Motion Analyzer software is a comprehensive sizing tool used for analysis, optimization, selection, and validation of your
Kinetix Motion Control system. Given any drive and compatible motor/actuator, Motion Analyzer software will provide
you with the data to determine the optimum drive and motor/actuator combination for your application.
You can also use Motion Analyzer software to build your bill of materials and receive an itemized list of system components
with catalog numbers and product descriptions.
Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives Chapter 4
• Motor Cables
• Interface Cables
Motion Control Accessories • Connector Kits
Chapter 12
• Power Components
Rotary System Combinations, in chapter 13, includes cable combinations, system performance specifications tables,
connector kit requirements, and torque/speed curves for the optimum drive/motor or drive/actuator combination.
Linear System Combinations, in chapter 14, includes cable combinations, system performance specifications tables,
connector kit requirements, and force/velocity curves for the optimum drive/actuator combination.
• 230V and 460V windings • 230V and 460V windings • Epoxy coated • Smooth, passivated 300 series
• High-energy rare-earth magnets • Multiple winding speed options • 230V and 460V windings stainless-steel cylindrical exterior.
• Shaft end threaded hole • High-energy rare-earth magnets • Shaft end threaded hole • Certified and listed to NSF/ANSI
Standard 169
• DIN connectors, rotates 180° • Shaft end threaded hole • SpeedTec-ready DIN connectors,
Features • Standard IEC 72-1 mounting • SpeedTec-ready DIN connectors, rotates 180° • 230V and 460V windings
dimensions rotates 180° • Standard IEC 72-1 mounting • Shaft end threaded hole
• Standard IEC 72-1 mounting dimensions • Cable extensions, 3 m (9.8 ft)
dimensions • Standard IEC 72-1 mounting
dimensions
• IP50 minimum, without shaft seal • IP50 minimum, without shaft seal • IP66/IP67 with shaft seal • IP66/IP67 with shaft seal
(standard). (standard). (standard) and use of (standard) and use of
Environmental rating • IP66 with optional shaft seal and • IP67 with optional shaft seal and environmentally sealed cable environmentally sealed cable
use of environmentally sealed use of environmentally sealed connectors. connectors.
cable connectors. cable connectors. • Food grade grease on shaft seal • IP69K for 1200 psi washdown
Continuous torque 0.26…163 N•m (2.3…1440 lb•in) 2.18…62.8 N•m (19.3…556 lb•in) 1.6…19.4 N•m (14…172 lb•in) 3.6…21.5 N•m (32…190 lb•in)
Peak torque 0.74…278 N•m (6.6…2460 lb•in) 6.6…154.2 N•m (58…1365 lb•in) 3.61…48.6 N•m (32…430 lb•in) 11.1…98 N•m (67.8…600 lb•in)
Speed Up to 8000 rpm Up to 7000 rpm Up to 5000 rpm 3000 and 5000 rpm
Environmental rating IP65 with use of environmentally sealed cable connectors. IP54
Continuous torque 32.7…426 N•m (289…3770 lb•in) 96…482 N•m (849…4266 lb•in)
Peak torque 86.5…1050 N•m (766…9293 lb•in) 192…964 N•m (1699…8531 lb•in)
Speed Base speeds between 177…1836 rpm Base speeds of 1500 and 3000 rpm
• Use to replace mechanical gear reduction (gear boxes, • High power packaging
belts, pulleys) • Converting
• Tight space constraints • Wind/unwind/rewind
Typical applications • Axes with high-power and high-performance • Sheeters
requirements
• Flying knife
• Material handling
• 230V windings
• High-energy Neodymium-Iron-Boron (NeFeB) magnets
Features • Cable extensions, 1 m (3.2 ft)
• 17-bit serial communication
• 24V DC brake
Motor options • Shaft seal kit
• Robotics
• Material handling
• X-Y tables
• Specialty machinery
Typical applications • Semiconductor manufacturing
• Medical/laboratory equipment
• Light packaging machines
• Office machinery
Motor type Iron core coil and magnet track Ironless coil and magnet channel
• Form-fill and seal packaging machines • Wafer cutting, handling and marking
• Large format gantries (pick and place, scribing and palletizing) • Computer-to-plate printing machines
• Material handling (pallet movers and sheet glass) • Large format printing (print head axis)
• Plasma, laser and water jet cutting machines • Solar and flat panel scribing (scribe head axis)
Typical applications • Machine tools • Axis requiring extremely smooth/constant velocity
• Flying cut off machines
• Coordinate measuring machines
• Large format routers
• Large format printers (step axis)
Linear Actuators
Actuators are UL Recognized components to applicable UL and CSA standards. CE marked for all applicable directives.
Refer to http://www.ab.com for more information.
• 200/230V and 400/460V operation (230V only for 150 mm direct-drive frame size)
• High-energy neodymium (NeFeB) magnets
• Heavy duty connectors
Features • Operation without limit and home switches
• Carriage and base mounting design allows 200 mm and 250 mm frame sizes to be stacked
• Standard MP-Series motor power and feedback connectors
• Optional air purge kit for added protection against ingress of foreign substances
Environmental rating Unique, long life strip seal system provides IP30 environmental rating to prevent debris, larger than 2.5 mm (0.1 in.) diameter, from entering the linear stage.
• Cable track module replacement kit • Cable track module replacement kit
• Strip seal replacement kit • Strip seal replacement kits
• Top cover • Top cover kits (for Y or Z-axis only)
• Side cover • Side cover kits
• Coupling • Coupling kits (for Y or Z-axis only)
Field-installable accessories • T-nut kit (package of 10) • Tee-nut kit (package of 10)
• Toe-clip kit (package of 10) • Tee-nut bar kit
• Grease gun kit • Grease gun kit
• Grease replacement cartridge • Grease replacement cartridge
• Rotary servo motor (for Y or Z-axis only)
(1) Applies to Bulletin MPAS linear stages. Not all Bulletin MPAS stroke lengths (travels) are available with Bulletin MPMA multi-axis linear stages.
• Fully assembled and ready to mount cylinders contribute to reductions in mechanical design engineering, wiring, and commissioning time
• Smart Motor Technology
• Very high linear speeds
ISO 15552 pneumatic-class frame sizes 32, 40, and 63 mm Frame sizes 83 and 110 mm
Actuator type Ball-screw driven electric cylinders Ball-screw and roller-screw electric cylinders
Peak velocities 0.15…1.0 m/s (5.9…39.4 in./s) 279…559 mm/s (11.0…22.0 in./s)
Stroke lengths (1) 100…800 mm (4.0…32.0 in.) 150, 300, 450 mm (6.0, 12.0, 18.0 in.)
• Material handling (loading, unloading, lifts, pick and place, diverters, transfers,
gantries)
• Volumetric filling and process control (web guides, valve, nozzle, van, and gate
positioning)
• Fabrication (adjustments for machine backstops and cutting tools, works
Typical applications alignment)
• Push, pull, eject, press, or clamp parts
• Packaging (consumer products, automotive, medical)
• Electronic assembly
• Insertion systems
• Inspection and test equipment
(1) Not all stroke lengths (travels) are available with all frame sizes.
Servo Drives
Servo drives meet CE compliance and are UL Listed to U.S. and Canadian safety standards. Refer to http://www.ab.com
for more information.
Servo Drives
Drive Features Kinetix 6500 Kinetix 6200 Kinetix 6000 Kinetix 7000
• Multi-axis • Multi-axis • High-power applications
• Common Bus • Common Bus • Common Bus
• Modular Design • Enhanced Peak Performance (1) • Integrated Motion Drive
Main characteristics • Integrated Motion Drive • Integrated Motion Drive
RSLogix 5000 software (Ladder Logic, Structured Text, and Sequential Function Charts)
Programming
Version 18 or later Version 17 or later Version 11 or later Version 15 or later
• High-resolution absolute multi-turn and single-turn encoder • High-resolution absolute multi-turn • High-resolution absolute multi-turn
• Incremental encoder and single-turn encoder and single-turn encoder
• EnDat 2.1 and 2.2 encoder support for RDD-Series (Bulletin • Incremental encoder • Incremental encoder
RDB) direct drive motors • EnDat 2.1 and 2.2 encoder support with • EnDat 2.1 and 2.2 encoder support
Feedback 2090-K6CK-KENDAT feedback module with 2090-K7CK-KENDAT feedback
• Resolver module
• MP-Series Linear Stages (Bulletin MPAS) • MP-Series Linear Stages (Bulletin MPAS)
Linear actuator • MP-Series Multi-axis Linear Stages (Bulletin MPMA) • MP-Series Multi-axis Stages (Bulletin MPMA)
N/A
compatibility • MP-Series Electric Cylinders (Bulletin MPAR and MPAI) • MP-Series Electric Cylinders (Bulletin MPAR
and MPAI)
• 2094 Line Interface Modules • 2094 Line Interface Modules • 8720MC Regenerative PS
Accessory • 2090 Resistive Brake Modules • 2090 Resistive Brake Modules • 8720MC Line Reactor
compatibility • 1394 External Passive Shunt • 1394 External Passive Shunt • 1336 External Active Shunt
• 1336 External Active Shunt • 2094 Line Interface Modules
(1) Refer to Kinetix 6000 IAM/AM Module Series Change on page 276 for more information.
Servo Drives
Drive Features Kinetix 2000 Kinetix 300 Kinetix 3
• Single-axis solution for low-complexity motion applications
• Low cost EtherNet/IP network solution with integrated safe • Single-axis solution for low-complexity
• Low-power SERCOS interface solution for torque-off functionality motion applications, with or without a PLC.
complex motion applications • Flexible control architecture for simple analog, PTO, or • Indexing, analog, preset velocity, and
Main Characteristics • Multi-axis EtherNet/IP Indexing control pulse-train command modes
• Common Bus • 120V models drive 240V motors at full speed • Modbus-RTU or I/O control
• Integrated Motion Drive • Memory module for Automatic Device Replacement (ADR) • Performs indexing on up to 64 points
Safe Torque-off Control, ISO-13849-1 Certified, PLd, category 3
• DriveExplorer
DPI Connector • DPI HIM
N/A
Feedback-only Auxiliary Axis Auxiliary axis for master gearing mode N/A
Servo Drives
Drive Features Ultra3000 (SERCOS) Ultra3000 (Non-SERCOS) Ultra5000
• Standalone • Standalone • Standalone
Main characteristics • SERCOS Interface • Indexing • Integrated Control
• Integrated Motion Drive • DeviceNet with Indexing • ANSI C Programmable
• 1756-M03SE • 1756-M02AE
• 1756-M08SE • 1756-HYD02
Logix module compatibility • 1756-M16SE • 1756-M02AS
N/A
• 1768-M04SE
• LDC-Series
Linear motors compatibility • LDL-Series
N/A
Additional Resources
Resource Description
Literature Library, Electronic copies of installation instructions, user manuals, and other publications
website http://www.rockwellautomation.com/literature related to your Kinetix Motion Control selection process.
Hardcopy motion control publications Your local Rockwell Automation distributor or sales representative.
Kinetix 6200 and Kinetix 6500 Safe Speed Monitoring Servo Information on wiring, configuring, and troubleshooting the safe-speed features of your
Drives Safety Reference Manual, publication 2094-RM001 Kinetix 6200 and Kinetix 6500 drives.
Kinetix 6200 and Kinetix 6500 Safe Torque-off Servo Drives Information on wiring, configuring, and troubleshooting the safe torque-off features of
Safety Reference Manual, publication 2094-RM002 your Kinetix 6200 and Kinetix 6500 drives.
Kinetix Safe-off Feature Safety Reference Manual, Information on wiring and troubleshooting your Kinetix 6000 and Kinetix 7000 servo
publication GMC-RM002 drives with the safe-off feature.
System Design for Control of Electrical Noise Reference
Manual, publication GMC-RM001 Information, examples, and techniques designed to minimize system failures caused by
electrical noise.
EMC Noise Management DVD, publication GMC-SP004
Information to determine which ControlLogix controller fits your application and the
ControlLogix Selection Guide, publication 1756-SG001 product specifications to help design a ControlLogix system and select the appropriate
components.
Information to determine which CompactLogix controller fits your application and the
CompactLogix Selection Guide, publication 1769-SG001 product specifications to help design a CompactLogix system and select the appropriate
components.
Integrated Architecture Recommended Literature Reference This document provides lists of technical publications for Integrated Architecture
Manual, publication IASIMP-RM001 products. These lists are not all-inclusive, but they do include the most-commonly
accessed publications for the related products.
Industrial Ethernet Media Brochure, publication 1585-BR001 Information to determine which Bulletin 1585 Ethernet cable fits your application and the
product specifications to help select the appropriate components.
Phone 440-646-5800
Technical Support Fax 440-646-5801
Email [email protected]
Motion Analyzer software download from Comprehensive motion application sizing tool used for analysis, optimization, selection,
http://www.ab.com/motion/software/analyzer.html and validation of your Kinetix Motion Control system.
Rockwell Automation Configuration and Selection Tools, Online product selection and system configuration tools, including AutoCad (DXF)
website http://www.ab.com drawings.
Notes:
Rotary Motion
Use this chapter to become familiar with the Kinetix Motion Control rotary servo motors and select the rotary motion
components required for your application. To compare features from one family of rotary motion components to another,
refer to Rotary Servo Motors on page 9.
Topic Page
Environmental Specifications
Attribute MP-Series RDD-Series TL-Series HPK-Series
Temperature, ambient 0…40 °C (32…104 °F)
Temperature, storage -30…70 °C (-22…158 °F)
Relative humidity 5…95%
(noncondensing)
10 g peak, 6 ms
Shock 20 g peak, 6 ms duration duration
Vibration 2.5 g peak @ 30…2000 Hz
Environmental Ratings
IP Rating Dust Protection Liquid Protection Shaft Seal Motor
Bulletin MPL
IP50 Limited protection No protection from liquids. and MPM
from dust (no Motor without shaft seal.
harmful deposit). TL-Series,
IP54 Protected against sprays from all directions.
HPK-Series
Motor with shaft seal (cable TL-Series
connectors rated IP54).
IP65 Protected against low-pressure jets of water from all directions.
RDD-Series (1)
The brakes are not designed for stopping rotation of the motor shaft. Servo drive inputs should be used to stop motor shaft
rotation. The recommended method of stopping motor shaft rotation is to command the servo drive to decelerate the
motor to 0 rpm, and engage the brake after the servo drive has decelerated the motor to 0 rpm.
If system mains power fails, the brakes can withstand use as stopping brakes. However, use of the brakes as stopping brakes
creates rotational mechanical backlash that is potentially damaging to the system, increases brake pad wear, and reduces
brake life. The brakes are not designed nor are they intended to be used as a safety device.
A separate power source is required to disengage the brake. This power source can be controlled by the servo motor
controls, in addition to manual operator controls. Electrical arcing may occur at the relay contacts until the brake power
dissipates. A customer supplied diode or metal oxide varistor (MOV) is recommended to prevent arcing. Use of an MOV
can also reduce the time to mechanically engage the brake. For brake response time specifications, refer to the motor brake
specification tables.
(1) Kinetix 2000, Kinetix 6000, Kinetix 6200, Kinetix 6500, and Kinetix 7000 servo drives provide motor brake relay outputs and supply an MOV arc suppressor, so customer
supplied arc suppressor is not required unless the coil current of motor brake is greater than the maximum brake current rating of the drive relay output.
MP-Series low-inertia motors are available with high performance encoders with a choice of Single-turn (-E, -S) or
Multi-turn (-V, -M) high resolution feedback.
• Up to 2 million counts per revolution (-M and -S) for smooth performance (MPL-A/B3xx, MPL-A/B4xx,
MPL-A/B45xx, MPL-A/B5xx, MPL-B6xx, MPL-B8xx, and MPL-B9xx motors).
• Up to 260 thousand counts per revolution (-E and -V) for smooth performance (MPL-A/B15xx and
MPL-A/B2xx motors).
• Single-turn encoder provides high-resolution absolute position feedback within one turn.
• Multi-turn encoder provides high-resolution absolute position feedback within 4096 turns. The electromechanical
design does not require a battery.
MP-Series (Bulletin MPL) motors are equipped with threaded and SpeedTec-ready DIN connectors.
SpeedTec DIN (M7) Cable Plug
O-ring
SpeedTec-ready
DIN Connectors
• 2090-CFBM7DF-CEAAxx (standard) flying-lead, feedback cables
• MPL-A/B3xxx…MPL-B9xxx motors
• 2090-CFBM7DD-CEAAxx (standard) drive-end connector, feedback cables
• Receives M4 and M7 cable plugs
(remove the O-ring for M7) • 2090-CFBM7DF-CEAFxx (continuous-flex) flying-lead, feedback cables
• Attach M7 cable plug with one-quarter turn • 2090-CFBM7DD-CEAFxx (continuous-flex) drive-end connector, feedback cables
• Attach M4 cable plug with 5…6 turns • 2090-CFBM7DF-CDAFxx (continuous-flex) flying-lead, feedback cables
• 2090-CPWM7DF-xxAAxx (standard) power-only cables
• 2090-CPBM7DF-xxAAxx (standard) power/brake cables
• 2090-CPWM7DF-xxAFxx (continuous-flex) power-only cables
• 2090-CPBM7DF-xxAFxx (continuous-flex) power/brake cables
Threaded DIN (M4) Cable Plug
Threaded
DIN Connectors
For information on transitioning your Bulletin MPL motor installation from bayonet cables to circular DIN cables, refer to
2090-Series Motor Power and Feedback Transition Cables on page 400.
B420P 5000 4.74 (42) 13.5 (120) 1.9 5000 0.00026 (0.0023) (2) 4.3 (9.4)
B430P 5000 6.55 (58) 19.8 (175) 2.2 5000 0.00038 (0.0033) (2) 5.5 (12)
B4530F 3000 8.25 (73) 20.3 (180) 2.1 3000
0.00040 (0.0036) (2) 7.3 (16)
B4530K 4000 8.25 (73) 20.3 (180) 2.6 4000
B4540F 3000 10.2 (90) 27.1 (240) 2.6 3000 0.00052 (0.0046) (2) 8.6 (19)
B4560F 3000 14.1 (125) 34.4 (305) 3.2 3000 0.00078 (0.0067) (2) 11.82 (26)
B520K 4000 10.7 (95) 23.2 (205) 3.5 3500 0.000783 (0.0069) 9.8 (21.5)
B540D 2000 19.4 (172) 41.0 (362) 3.4 2000 0.00147 (0.013)
15 (33)
B540K 4000 19.4 (172) 48.6 (430) 5.4 4000 0.00147 (0.013)
B560F 3000 26.8 (237) 67.8 (600) 5.5 3000 0.00213 (0.019) 20.2 (44.5)
B580F 3000 34.0 (301) 87.0 (770) 7.1 3000
0.00289 (0.023) 25.4 (56)
B580J 3800 34.0 (301) 81.0 (716) 7.9 3800
B640F 3000 36.7 (325) 72.3 (640) 6.11 2000 0.004 (0.0354) 26.8 (59)
B660F 3000 48.0 (425) 101.1 (895) 6.15 2000 0.0058 (0.051) 35.0 (77)
B680D 2000 62.8 (556) 154.2 (1365) 9.3 2000
0.00775 (0.0685) 40.4 (89)
B680F 3000 60.0 (531) 108.5 (960) 7.5 2000
B860D 2000 83.0 (735) 152.5 (1350) 12.5 2000 0.0169 (0.150) 57.3 (126)
B880C 1500 110.0 (973) 203 (1800) 12.6 1500
0.0224 (0.198) 72.7 (160)
B880D 2000 110.0 (973) 147 (1300) 12.6 2000
B960B 1200 130.0 (1150) 231 (2050) 12.7 1200
B960C 1500 124.3 (1100) 226 (2000) 14.8 1500 0.0273 (0.242) 76.0 (167)
B960D 2000 124.3 (1100) 226 (2000) 15.0 2000
B980B 1000 162.7 (1440) 278 (2460) 15.2 1000
B980C 1500 158.2 (1400) 271 (2400) 16.8 1500
0.0354 (0.313) 94.5 (208)
B980D 2000 158.2 (1400) 260 (2300) 18.6 2000
B980E 2750 141.0 (1250) 237 (2100) 13.0 1500
(1) Refer to MP-Series Low Inertia Motor Brake Specifications on page 25 for Brake Rotor Inertia and Brake Motor Weight.
(2) Rotor inertia may vary slightly depending on feedback.
(1) MPL-B15xxx and MPL-B2xxx motors are not compatible with Ultra5000 drives. All
other MPL-Bxxxx motors are compatible with both Ultra3000 and Ultra5000 drives.
Shaft
D Diameter N
HD See Detail A
AD
Feedback
Connector
LE
53.9 Power/Brake Connector
(2.12) LD
Shaft End Threaded Hole
Detail A Shaft Diameter Tolerances MPL-A/B1510, -A/B1520, -A/B1530 Motors:
2.8 ±0.30
MPL-A/B1510, -A/B1520, -A/B1530 Motors: Thread - M3 x 0.5-6H
(0.110 ±0.012) Thread Depth - 9.0 (0.35)
Ø 8.998…9.007 (0.3543…0.3546)
MPL-A/B210, -A/B220, -A/B230 Motors:
MPL-A/B210, -A/B220, -A/B230 Motors:
MPL-A/B1510, -A/B1520, -A/B1530 and Thread - M4 x 0.7-6H
Ø 10,997…11.008 (0.4330…0.4334)
MPL-A/B210, -A/B220, -A/B230 Motors: Thread Depth - 10.0 (0.39)
Ø 11.89…11.95 (0.468…0.470)
Shaft, Pilot, and
Keyway Tolerances MPL-A/B15xx MPL-A/B2xx
Shaft Detail with Key
Optional Shaft Seal
Refer to page 22 Shaft Runout (T.I.R.) 0.030 (0.0012) 0.035 (0.0014)
for MP-Series Pilot Eccentricity (T.I.R.) 0.08 (0.0031) 0.08 (0.0031)
small frame motor G
shaft seal kit information. Max Face Runout (T.I.R.) 0.08 (0.0031) 0.08 (0.0031)
7.10…7.20 8.40…8.50
F Keyway Depth (G) (0.280…0.283) (0.331…0.335)
MPL-A/B1510, -A/B1520, -A/B1530 = 3 x 3 x 14 Key 2.971…2.996 3.97…4.00
MPL-A/B210, -A/B220, -A/B230 = 4 x 4 x 16 Key Keyway Width (F) (0.117…0.118) (0.156…0.157)
Motor
Series AD HD T LA LD (1) LE (1) L (1) LB (1) D M S (3) N P G F
MPL-A mm mm mm mm L-LB (2) mm mm mm mm mm mm
mm mm mm mm mm
or (in.) (in.) (in.) (in.) mm (in.) (in.) (in.) (in.) (in.) (in.) (in.)
(in.) (in.) (in.) (in.) (in.)
MPL-B
78.3 39.2 133.2 113.5
1510 (3.08) (1.54) (5.25) (4.47)
66.5 94.0 2.50 9.0 91.3 52.4 146.2 126.5 19.7 9.0 63.0 5.80 40.0 55.0 7.2 3.0
1520 (2.62) (3.70) (0.098) (0.35) (3.60) (2.06) (5.76) (4.98) (0.776) (0.35) (2.480) (0.228) (1.57) (2.17) (0.283) (0.118)
116.3 77.2 171.2 151.5
1530 (4.58) (3.04) (6.74) (5.96)
78.6 39.6 137.3 114.6
210 (3.09) (1.56) (5.40) (4.51)
74.0 109 2.50 9.0 104.1 65.1 162.8 140.1 22.7 11.0 75.0 5.80 60.0 70.0 8.5 4.0
220 (2.91) (4.29) (0.098) (0.35) (4.10) (2.56) (6.41) (5.52) (0.894) (0.43) (2.953) (0.228) (2.36) (2.76) (0.335) (0.157)
129.6 90.6 188.3 165.6
230 (5.10) (3.57) (7.41) (6.52)
(1) If ordering an MPL-A/B1510, A/B1520, or A/B1530 motor with brake, add 36.1 mm (1.421 in.) to dimension L and LB, and add 33.4 mm (1.32 in.) to LD and LE.
If ordering an MPL-A/B210, A/B220, or A/B230 motor with brake, add 39.0 mm (1.535 in.) to dimension L and LB, and add 24.7 mm (0.97 in.) to LD and LE.
(2) Tolerance for this dimension is ±0.7 mm (±0.028 in.).
(3) Tolerance for this dimension is +0.3 mm (+0.012 in.).
Motors are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
MPL-A540, L-LB
Pilot Diameter
MPL-A560, LA Pilot Diameter Tolerances
MPL-B580 S Diameter Holes on P MPL-A/B310, -A/B320, -A/B330 Motors:
T M Diameter Bolt Circle. Ø 79.993…80.012 (3.1493…3.1501)
MPL-A/B420, -A/B430 Motors:
Ø 94.991…95.013 (3.7398…3.7407)
D Shaft Diameter MPL-A/B4530, -A/B4540, -A/B4560 Motors:
N Ø 109.991…110.013 (4.3303…4.3312)
Rotary Motion
MPL-A/B520, -A/B540, -A/B560, -B580 Motors: Shaft Runout (T.I.R.) 0.035 (0.0014) 0.04 (0.0016) 0.04 (0.0016) 0.04 (0.0016) 0.05 (0.002)
Ø 29.92 ±0.05 (1.178 ±0.002)
Pilot Eccentricity (T.I.R.) 0.08 (0.0031) 0.08 (0.0031) 0.10 (0.0039) 0.10 (0.0039) 0.10 (0.0039)
Max Face Runout (T.I.R.) 0.08 (0.0031) 0.08 (0.0031) 0.10 (0.0039) 0.10 (0.0039) 0.10 (0.0039)
3.00…3.10 3.50…3.60 4.00…4.20 4.00…4.20 5.00…5.20
Keyway Depth (GE) (0.118…0.122) (0.138…0.142) (0.158…0.165) (0.158…0.165) (0.197…0.205)
4.97…5.00 5.97…6.00 7.96…8.00 7.964…8.000 9.964…10.000
Keyway Width (F) (0.196…0.197) (0.235…0.236) (0.314…0.315) (0.3135…0.3150) (0.3923…0.3937)
MPL-A/B3xx, MPL-A/B4xx, MPL-A/B45xx, MPL-A/B5xx Motor Dimensions (SpeedTec DIN connectors)
Motor
AD HD T LA LD (1) LE (1) L (1) LB (1) L-LB (2) D M S (3) N P GE F
Series
mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
MPL-
102.0 62.0 168.0 128.0
A/B310 (4.03) (2.45) (6.62) (5.04)
87.2 132.0 2.74 9.90 128.0 88.0 193.0 153.0 40.0 16.0 100.0 7.0 80.0 89.4 3.0 5.0
A/B320
(3.44) (5.20) (0.108) (0.39) (5.03) (3.45) (7.62) (6.04) (1.58) (0.629) (3.937) (0.283) (3.15) (3.52) (0.118) (0.197)
153.0 113.0 219.0 179.0
A/B330 (6.03) (4.45) (8.62) (7.04)
Motors are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions without tolerances are for reference.
29
Chapter 1
Chapter 1 Rotary Motion
N2
D Shaft Diameter
N1
HD
AD See Detail A
N
D Shaft Diameter
HD
AD
See Detail A
MPL-B860D,
LE
MPL-B880C
M23 Feedback Connector Feedback Shaft-end Threaded Hole
M40 Power/Brake Connector Connector Thread = M16 x 2.0-6H
94 (3.70)
LD Power/Brake Thread Depth = 36 (1.42)
AD HD
+10 (0.39) +10 (0.39) Connector
LE - 13 (0.51) MPL-B880D
M23 Feedback Connector
127 (5.0) M58 Power/Brake Connector Connector housing may be rotated
for rearward connector orientation.
Shaft Diameter Tolerances
Flush to Pilot Ø 42.002…42.018 (1.6536…1.6542)
Detail A Shaft, Pilot, and
± 0.84 (0.033) MPL-B8xx
Keyway Tolerances
Shaft Detail with Key
Shaft Runout (T.I.R.) 0.05 (0.0016)
Ø 44.91 ± 0.05
(1.768 ± 0.002) Pilot Eccentricity (T.I.R.) 0.10 (0.0039)
GE Max Face Runout (T.I.R.) 0.10 (0.0039)
5.00…5.20
Optional Shaft Seal F Keyway Depth (GE)
(0.197…0.205)
Refer to page 22 Key = 12 x 8 x 79 11.957…12.000
for MP-Series motor Keyway Width (F)
(0.4708…0.4724)
shaft seal kit information.
Motor M S (1) N P GE F
Series mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
MPL-B860 265 14.50 230 235 5.0 12.0
MPL-B880 (10.43) (0.579) (9.055) (9.25) (0.197) (0.4724)
L
LB Pilot Diameter Tolerance
Dimensions are in mm (in.) L-LB
Ø 249.987…250.016 (9.8420…9.8431)
LA
S Diameter Holes on P
T M Diameter Bolt Circle
N
D Shaft Diameter
AD HD
See Detail A
LE MPL-B960B, MPL-B980B
with M23 Feedback Connector Feedback Shaft End Threaded Hole
M40 Power/Brake Connector Connector Thread = M16 x 2.0-6H
94 (3.70) LD Thread Depth = 36 (1.42)
AD HD Power/Brake
+11 (0.43) +11 (0.43) Connector
MPL-B960C, MPL-B960D, MPL-B980C,
LE - 14 (0.55) MPL-B980D, MPL-B980E
with M23 Feedback Connector
M58 Power/Brake Connector Connector housing may be rotated
131 (5.16)
for rearward connector orientation.
Shaft Diameter Tolerances
Ø 48.002…48.018 (1.8899…1.8905)
Detail A Flush to Pilot
± 0.84 (0.033) Shaft, Pilot, and
Keyway Tolerances MPL-B9xx
Shaft Detail with Key
Ø 51.89 ± 0.07 Shaft Runout (T.I.R.) 0.05 (0.002)
(2.043 ± 0.003) Pilot Eccentricity (T.I.R.) 0.125 (0.005)
GE Max Face Runout (T.I.R.) 0.125 (0.005)
F 5.50…5.70
Optional Shaft Seal Keyway Depth (GE) (0.217…0.224)
Refer to page 22 Key = 14 x 9 x 79
for MP-Series motor 13.957…14.000
Keyway Width (F) (0.5495…0.5512)
shaft seal kit information.
Motor M S (1) N P GE F
Series mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
MPL-B960 300 18.50 250 267 5.50 14.0
MPL-B980 (11.81) (0.738) (9.84) (10.50) (0.217) (0.5512)
Bulletin MPL motors are capable of operating with the maximum radial or maximum axial shaft loads listed in the
following tables. Radial loads listed are applied in the middle of the shaft extension. The tables starting below represent an
L10 bearing fatigue life of 20,000 hours. This 20,000-hour life does not account for possible application-specific life
reduction that may occur due to bearing grease contamination from external sources. Maximum operating speed is limited
by motor winding.
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your motor. For questions regarding product
availability, contact your Allen-Bradley distributor.
MP L - x xx xx x -x x x x A A
Factory Options
A = Standard
Mounting Flange
A = IEC metric, free mounting holes (type FF)
Brake
2 = No Brake
4 = 24V DC Brake
Connectors
4 = Circular (threaded) DIN connector, right angle, 180° rotatable (1)
7 = Circular (SpeedTec) DIN connector, right angle, 180° rotatable (2)
Enclosure/Shaft Key/Shaft Seal
J = Shaft key/No shaft seal
K = No shaft key/No shaft seal (3)
Feedback
V = Multi-turn, 128 sin/cos, absolute encoder (Hiperface protocol) (1)
M = Multi-turn, 1024 sin/cos, absolute encoder (Hiperface protocol) (2)
E = Single-turn, 128 sin/cos, absolute encoder (Hiperface protocol) (1)
S = Single-turn, 1024 sin/cos, absolute encoder (Hiperface protocol) (2)
H = 2000 lines/revolution, incremental encoder (4)
R = Resolver (5)
Rated Speed (6)
B = 1000 rpm H = 3500 rpm T = 6000 rpm
C = 1500 rpm J = 3750 rpm U = 7000 rpm
D = 2000 rpm K = 4000 rpm V = 8000 rpm
F = 3000 rpm P = 5000 rpm
Magnet Stack Length (6)
10 = 25.4 mm (1.0 in.) 50 = 127.0 mm (5.0 in.)
20 = 50.8 mm (2.0 in.) 60 = 152.4 mm (6.0 in.)
30 = 76.2 mm (3.0 in.) 70 = 177.8 mm (7.0 in.)
40 = 101.6 mm (4.0 in.) 80 = 203.2 mm (8.0 in.)
Frame Size
15 = 63 mm 5 = 165 mm
2 = 75 mm 6 = 215 mm
3 = 100 mm 8 = 265 mm
4 = 115 mm 9 = 300 mm
45= 130 mm
Voltage Class
A = 200V
B = 400V
Series Type
L = Low Inertia
Series
MP = Premium permanent magnet rotary servo motor
MP-Series medium-inertia motors are available with high performance encoders with a choice of Single-turn (-S) or
Multi-turn (-M) high-resolution feedback.
• Up to 2 million counts per revolution (-M and -S) for smooth performance.
• Single-turn encoder provides high-resolution absolute position feedback within one turn.
• Multi-turn encoder provides high-resolution absolute position feedback within 4096 turns. The electromechanical
design does not require a battery.
MP-Series (Bulletin MPM) motors are equipped with SpeedTec-ready DIN connectors.
SpeedTec DIN (M7) Cable Plug
O-ring
SpeedTec-ready
DIN Connectors
• 2090-CFBM7DF-CEAAxx (standard) flying-lead, feedback cables
• MPM-A/Bxxx motors
• 2090-CFBM7DD-CEAAxx (standard) drive-end connector, feedback cables
• Receives M4 and M7 cable plugs
(remove the O-ring for M7) • 2090-CFBM7DF-CEAFxx (continuous-flex) flying-lead, feedback cables
• Attach M7 cable plug with one-quarter turn • 2090-CFBM7DD-CEAFxx (continuous-flex) drive-end connector, feedback cables
• 2090-CFBM7DF-CDAFxx (continuous-flex) flying-lead, feedback cables
End Cap
Pilot Diameter
MPM-A165xx, LA
MPM-B165xx S Diameter Holes on P
T Pilot Diameter Tolerances
M Diameter Bolt Circle
MPM-A/B115xx Motors:
Ø 94.991…95.013 (3.7398…3.7407)
N2 MPM-A/B130xx Motors:
D Shaft Diameter Ø 109.991…110.013 (4.3303…4.3312)
N1
Rotary Motion
HD MPM-A/B165xx Motors:
Ø 129.991…130.014 (5.1178…5.1187)
See Detail A
AD
MPM-A/B115xx, Shaft End Threaded Hole
LE
MPM-A/B130xx, MPM-A/B115xx Motors:
MPM-B165xx with Thread - M6 x 1.0-6H
MPM-A/B115xx = 67.7 (2.66) M23 Feedback Thread Depth - 16 (0.63)
LD Feedback Power
MPM-A/B130xx = 67.7 (2.66) and Power MPM-A/B130xx Motors:
Connector Connector
MPM-B165xx = 68.2 (2.68) Connectors Thread - M8 x 1.25-6H
Thread Depth - 19 (0.75)
AD HD MPM-A/B165xx Motors:
Thread - M10 x 1.5-6H
MPM-A/B165xx with Thread Depth - 22 (0.87)
LE M23 Feedback
MP-Series Medium Inertia Motor Dimensions
MPM-A/B115xx Motors: GE
Ø 18,996…19,009 (0.7479…0.7483) Optional Shaft Seal
Detail A MPM-A/B115xx Motors: MPM-A/B130xx Motors: Refer to page 38
Flush to 2.87 (0.113) Pilot ± 0,83 (0.032) F
Ø 23,996…24,009 (0.9448…0.9451) for MP-Series motor
MPM-A/B130xx, MPM-A/B165xx Motors: shaft seal kit information. MPM-A/B115xx = 6 x 6 x 25 Key
MPM-A/B165xx Motors: MPM-A/B130xx = 8 x 7 x 32 Key
Flush to 3.38 (0.133) Pilot ± 0,83 (0.032)
Ø 27,996…28,009 (1.1022…1.1027) MPM-A/B165xx = 8 x 7 x 40 Key
Motors are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions without tolerances are for reference.
43
Chapter 1
Chapter 1 Rotary Motion
N2
D Shaft Diameter
N1
HD
AD See Detail A
(1) If ordering an MPM-A/B215x motor with brake, add 88.9 mm (3.5 in.) to dimensions LD, LE, L, and LB.
(2) Tolerance for this dimension is ±0.7 mm (±0.028 in.).
(3) Tolerance for this dimension is +0.43 mm (±0.008 in.).
Motors are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
Bulletin MPM motors are capable of operating with the maximum radial or maximum axial shaft loads listed in the
following tables. Radial loads listed are applied in the middle of the shaft extension. The tables starting below represent an
L10 bearing fatigue life of 20,000 hours. This 20,000-hour life does not account for possible application-specific life
reduction that may occur due to bearing grease contamination from external sources. Maximum operating speed is limited
by motor winding.
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your motor. For questions regarding product
availability, contact your Allen-Bradley distributor.
MP M - x xxx x x -x J 7 x A A
Factory Options
A = Standard
Mounting Flange
A = IEC metric, free mounting holes (type FF)
Brake
2 = No brake
4 = 24V DC brake
Connectors
7 = Circular (SpeedTec) DIN connector, right angle, 180° rotatable
Enclosure/Shaft Key/Shaft Seal
J = Shaft key/No shaft seal
Feedback
2 = Resolver, 4 pole (1)
M = Multi-turn, 1024 sin/cos, absolute encoder (Hiperface protocol)
S = Single-turn, 1024 sin/cos, absolute encoder (Hiperface protocol)
Base Speed (2)
B = 2300 rpm
C = 1500 rpm
E = 2250 rpm
F = 3000 rpm
M = 4500 rpm
T = 6000 rpm
Magnet Stacks (2)
1 = 1 stack
2 = 2 stacks
3 = 3 stacks
4 = 4 stacks
Frame Size - Bolt Circle Diameter (BCD)
115 = 115 mm
130 = 130 mm
165 = 165 mm
215 = 215 mm
Voltage Class
A = 200V
B = 400V
Series Type
M = Medium Inertia
Series
MP = Premium permanent magnet rotary servo motor
Notes:
MP-Series (Bulletin MPF) motors are equipped with SpeedTec-ready DIN connectors.
SpeedTec DIN (M7) Cable Plug
O-ring
SpeedTec-ready
DIN Connectors
LA
Pilot Diameter Tolerances
T S Diameter Holes on P MPF-A/B310, -A/B320, -A/B330 Motors:
M Diameter Bolt Circle Ø 79.993…80.012 (3.1493…3.1501)
MPF-A/B430 Motors:
Ø 94.991…95.013 (3.7398…3.7407)
D Shaft Diameter N MPF-A/B4530, -A/B4540 Motors:
Ø 109.991…110.013 (4.3303…4.3312)
Rotary Motion
HD MPF-A/B540 Motors:
AD See Detail A Ø 129.989…130.014 (5.1177…5.1187)
± 0.83 (0.032) MPF-A/B310, -A/B320, -A/B330 Motors: MPF-A/B4530, -A/B4540 Motors: Refer to page 50
Ø 15.989…16.013 (0.6295…0.6305) Ø 23.996…24.009 (0.9448…0.9451) for MP-Series
MPF-A/B310, -A/B320, -A/B330 Motors: Food Grade motors
MPF-A/B430 Motors: MPF-A/B540 Motors:
Ø 16.94 ±0.05 (0.667 ±0.002) shaft seal kit information.
Ø 18.996…19.009 (0.7479…0.7483) Ø 27.996…28.009 (1.1022…1.1027)
MPF-A/B430 Motors:
Ø 19.94 ±0.05 (0.785 ±0.002)
MPF-A/B4530, -A/B4540 Motors: Shaft Detail with Key
Motor
AB AD HD T LA LD (1) LE (1) L (1) LB (1) L-LB (2) D M S (3) N P GE F
Series
mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
MPF-
102.0 62.0 168.0 128.0
A/B310
(4.03) (2.45) (6.62) (5.04)
66.0 87.25 133.4 2.74 9.91 128.0 88.0 193.0 153.0 40.0 16.0 100.0 7.0 80.0 92.39 3.0 5.0
A/B320
(2.60) (3.43) (5.25) (0.11) (0.39) (5.03) (3.45) (7.62) (6.04) (1.57) (0.629) (3.94) (0.283) (3.15) (3.64) (0.118) (0.197)
153.0 113.0 219.0 179.0
A/B330
(6.03) (4.45) (8.62) (7.04)
67.7 90.9 142.0 2.74 10.16 150.0 110.0 215.0 175.0 40.0 19.0 115.0 10.0 95.0 102.1 3.5 6.0
A/B430
(2.66) (3.58) (5.59) (0.11) (0.40) (5.89) (4.31) (8.48) (6.90) (1.57) (0.748) (4.53) (0.401) (3.74) (4.02) (0.138) (0.236)
153.0 113.0 229.0 179.0
A/B4530
67.7 98.6 157.6 2.74 12.19 (6.02) (4.44) (9.0) (7.03) 50.0 24.0 130.0 10.0 110.0 118.1 4.0 8.0
(2.66) (3.88) (6.20) (0.11) (0.48) 178.0 138.0 254.0 204.0 (1.97) (0.945) (5.12) (0.401) (4.33) (4.65) (0.158) (0.315)
A/B4540
(7.02) (5.44) (10.0) (8.03)
71.2 136.4 209.0 3.12 13.97 202.0 162.0 287.0 227.0 60.0 28.0 165.0 12.0 130.0 145.3 4.0 8.0
A/B540
(2.80) (5.37) (8.23) (0.12) (0.55) (7.95) (6.38) (11.30) (8.92) (2.36) (1.102) (6.50) (0.481) (5.12) (5.72) (0.158) (0.315)
(1) If ordering an MPF-A/B310, MPF-A/B320, or MPF-A/B330 motor with brake, add 35 mm (1.38 in.) to dimensions L, LB, LD, and LE.
If ordering an MPF-A/B430 motor with brake, add 48 mm (1.89 in.) to dimensions L, LB, LD, and LE.
If ordering an MPF-A/B4530 or MPF-A/B4540 motor with brake, add 23 mm (0.90 in.) to dimensions L, LB, LD, and LE.
If ordering an MPF-A/B540 motor with brake, add 51 mm (2.0 in.) to dimensions L, LB, LD, and LE.
(2) Tolerance for this dimension is ±0.7 mm (±0.028 in.).
(3) Tolerance for this dimension is: MPF-A/B3xx, MPF-A/B4xx, or MPF-A/B45xx +0.36 mm (±0.007 in.) and MPF-A/B5xx +0.43 mm (±0.008 in.).
Motors are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions without tolerances are for reference.
53
Chapter 1
Chapter 1 Rotary Motion
Bulletin MPF motors are capable of operating with the maximum radial or maximum axial shaft loads listed in the
following tables. Radial loads listed are applied in the middle of the shaft extension. The tables below represent an L10
bearing fatigue life of 20,000 hours. This 20,000-hour life does not account for possible application-specific life reduction
that may occur due to bearing grease contamination from external sources. Maximum operating speed is limited by motor
winding.
MP F - x xx xx x -x J 7 x B A
Factory Options
A = Standard
Mounting Flange
B = IEC metric (oversized), free mounting holes (type FF)
Brake
2 = No brake
4 = 24V DC brake
Connectors
7 = Circular (SpeedTec) DIN connector, right angle, 180° rotatable
Enclosure/Shaft Key
J = IP66/IP67 housing/Keyed shaft
Feedback
M = Multi-turn, 1024 sin/cos, absolute encoder (Hiperface protocol)
S = Single-turn, 1024 sin/cos, absolute encoder (Hiperface protocol)
Rated Speed (1)
F = 3000 rpm
H = 3500 rpm
K = 4000 rpm
P = 5000 rpm
Magnet Stack Length (1)
10 = 25.4 mm (1.0 in.)
20 = 50.8 mm (2.0 in.)
30 = 76.2 mm (3.0 in.)
40 = 101.6 mm (4.0 in.)
Frame Size
3 = 100 mm
4 = 115 mm
45 = 130 mm
5 = 165 mm
Voltage Class
A = 200V
B = 400V
Series Type
F = Food grade enclosure (including shaft seal)
Series
MP = Premium permanent magnet rotary servo motor
(1) Not all combinations are available. Only the configurations for rated speed and magnet stack length as listed in MP-Series Food Grade (230V) Performance Specifications
(page 50) and MP-Series Food Grade Motor (460V) Performance Specifications (page 51) are available.
MP-Series Stainless Steel motors are available with high performance encoders with a choice of Single-turn (-S) or
Multi-turn (-M) high resolution feedback.
• Up to 2 million counts per revolution for smooth performance
• Single-turn encoder provides high-resolution absolute position feedback within one turn.
• Multi-turn encoder provides high-resolution absolute position feedback within 4096 turns.
MP-Series (Bulletin MPS) motors are equipped with threaded DIN connectors.
Threaded DIN
Power Connector Threaded DIN (M4) Cable Plug
Motor Series Shaft Seal Cat. No. Inside Outside Inside Outside
Width Width
Diameter Diameter Diameter Diameter
mm (in.) mm (in.)
mm (in.) mm (in.) mm (in.) mm (in.)
MPS-A3xx and MPF-B3xx MPS-SST-A3B3 23.0 (0.90) 47.0 (1.85) 6.0 (0.24) 16.0 (0.63) 50.8 (2.0) 5.1 (0.20)
MPS-A45xx and MPF-B45xx MPS-SST-A45B45 31.0 (1.22) 62.0 (2.44) 7.0 (0.27) 24.0 (0.94) 63.5 (2.50) 5.2 (0.20)
MPS-B5xx MPS-SST-F165 36 (1.42) 72 (2.84) 8 (0.32) 28 (1.10) 82.6 (3.25) 5.1 (0.20)
Power/Brake Connector 3
MPS-A/B330 faceplate is shown. MPS-A/B4540 and LE Bolt Circle Threaded Hole Shaft End Threaded Hol
MPS-B560 faceplate has additional screws evenly spaced. MPS-A/B330 Motors: MPS-A/B330 Motors:
Shaft Diameter Tolerances Thread - M6 x 1.0 Thread - M5 x 0.8-6H
Detail A Flush to Pilot MPS-A/B330 Motors: Thread Depth - 7.0 (0.28) Thread Depth - 12.5 (0.49)
± 0.83 (0.032) Ø 15.997…16.008 (0.6298…0.6301) MPS-A/B4540 Motors: MPS-A/B4540 Motors:
MPS-A/B4540 Motors: Thread - M8 x 1.25-6H Thread - M8 x 1.25-6H
Ø 23.996…24.009 (0.9448…0.9451) Thread Depth - 9.0 (0.35) Thread Depth - 19 (0.75)
MPS-A/B330 Motors: MPS-B560 Motors: MPS-B560 Motors: MPS-B560 Motors:
Ø 16.891…16.896 (0.6650…0.6652) Ø 27.996…28.009 (1.1022…1.1027) Thread - M10 x 1.5-6H Thread - M10 x 1.5-6H
MPS-A/B4540 Motors: Thread Depth - 11 (0.43) Thread Depth - 22 (0.87)
Ø 24.94 ±0.05 (0.982 ±0.002)
MPS-A/B560 Motors: Shaft, Pilot, and Keyway Tolerances MPS-A/B330 MPS-A/B4540 MPS-B560
Ø 29.92 ±0.05 (1.178 ±0.002) Shaft Detail with Key
Shaft Runout (T.I.R.) 0.035 (0.0014) 0.04 (0.0016) 0.04 (0.0016)
Pilot Eccentricity (T.I.R.) 0.08 (0.0031) 0.10 (0.0039) 0.10 (0.0039)
Optional Shaft Seal
(with slinger) GE Max Face Runout (T.I.R.) 0.08 (0.0031) 0.10 (0.0039) 0.10 (0.0039)
Refer to page 57 3.00…3.10 4.00…4.20 4.00…4.20
F Keyway Depth (GE)
for MP-Series (0.118…0.122) (0.158…0.165) (0.158…0.165)
Stainless Steel motor MPS-A/B330 = 5 x 5 x 25 Key
4.97…5.00 7.96…8.00 7.96…8.00
shaft seal kit information. MPS-A/B4540 = 8 x 7 x 32 Key Keyway Width (F)
(0.196…0.197) (0.314…0.315) (0.314…0.315)
MPS-B560 = 8 x 7 x 40 Key
A/B4540 164 3.38 41.4 185 266 216 50.0 24.0 63.5 130 9.0 110 143.2 4.0 8.0
(6.46) (0.133) (1.63) (7.30) (10.45) (8.48) (1.97) (0.945) (2.50) (5.12) (0.35) (4.33) (5.64) (0.158) (0.315)
198 3.38 51.52 302 396 336 60.0 28.0 82.6 165 11.0 130 181 4.0 8.0
B560 (7.79) (0.13) (2.03) (11.90) (15.60) (13.24) (2.36) (1.10) (3.25) (6.49) (0.43) (5.12) (7.13) (0.158) (0.315)
(1) If ordering an MPS-A/B330 motor with brake, add 35 mm (1.38 in.) to dimensions L and LB, and 34 mm (1.34 in.) to dimension LE.
If ordering an MPS-A/B4540 motor with brake add 48.5 mm (1.91 in.) to dimensions L, LB, and LE.
(2) Tolerance for this dimension is ±0.7 mm (±0.028 in.).
(3) Specifications for the 3 m (9.8 ft) power and feedback cable leads are identical to those of the 2090-XXNPMF-xxSxx (power) and 2090-XXNFMF-Sxx (feedback) cables.
Refer to 2090-Series Motor/Acutator Cables with SpeedTec DIN Connectors Overview beginning on page 396 for more information.
Motors are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
Bulletin MPS motors are capable of operating with the maximum radial or maximum axial shaft loads listed in the
following tables. Radial loads listed are applied in the middle of the shaft extension. The tables starting below represent an
L10 bearing fatigue life of 20,000 hours. This 20,000-hour life does not account for possible application-specific life
reduction that may occur due to bearing grease contamination from external sources. Maximum operating speed is limited
by motor winding.
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your motor. For questions regarding product
availability, contact your Allen-Bradley distributor.
MP S - x xx xx x -x J 5 x D A
Factory Options
A = Standard
Mounting Flange
D = IEC metric, tapped mounting holes (type FT)
Brake
2 = No brake
4 = 24V DC brake
Connectors (1)
5 = Cables with circular DIN (threaded) connector
Enclosure/Shaft Key/Shaft Seal
J = IP66/IP67/IP69K housing/Shaft key/Shaft seal
Feedback
M = Multi-turn, 1024 sin/cos, absolute encoder (Hiperface protocol)
S = Single-turn, 1024 sin/cos, absolute encoder (Hiperface protocol)
Rated Speed (2)
F = 3000 rpm
P = 5000 rpm
Magnet Stack Length (2)
30 = 76.2 mm (3.0 in.)
40 = 101.6 mm (4.0 in.)
60 = 152.4 mm (6.0 in.)
Frame Size
3 = 100 mm
45 = 130 mm
5 = 165 mm
Voltage Class
A = 200V
B = 400V
Series Type
S = Stainless Steel
Series
MP = Premium permanent magnet rotary servo motor
(1) The motor has 3 m (9.8 ft) cables with nickel-plated connector extensions.
IMPORTANT The connectors are O-ring sealed, but not designed to withstand direct high-pressure washdown with aggressive
cleaning compounds. The 3 m (9.8 ft) cables are provided so the connectors can be positioned in an area away
from direct exposure to the cleaning process, such as within washdown-rated conduit or junction boxes.
(2) Not all combinations are available. Only the configurations for rated speed and magnet stack length as listed in MP-Series Stainless Steel Motor Performance
Specifications (page 58) and MP-Series Stainless Steel Motor (460V) Performance Specifications (page 58) are available.
Use the 2090-K6CK-KENDAT feedback module (Kinetix 6000 drives) and 2090-K7CK-KENDAT feedback module
(Kinetix 7000 drives) for wiring motor feedback connections. Support for Kinetix 6200 and Kinetix 6500 drives has not
been implemented.
RDD-Series motors are equipped with SpeedTec-ready DIN connectors, however, EnDat encoder feedback requires the
additional conductors included in the cables listed.
O-ring SpeedTec DIN (M7) Cable Plug
SpeedTec-ready
DIN Connectors
HD
Rotary Motion
AD
Bulletin RDB-B215xx Motor Dimensions
LB
(6.4563…6.4572)
M23 Feedback
Connector M40 Power Pilot Diameter (NB) Tolerance
Connector Ø 164.040…164.090
Shaft Diameter (D) Tolerance (6.4583…6.4602)
81.9
(3.22) Ø 70.985…71.000
(2.7947…2.7953) Machine Mounting Dimensions
Shaft Diameter (DB) Tolerance EB
Ø 71.985…72.000
(2.8340…2.8346)
E
NB
TB
Bulletin RDB-B215xx Motor Dimensions
)
Motor
AD (1) HD (1) T LA LD LE LB (2) D DB E (3) EB (4) TB M S (5) N NB P
Series
mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
RDB-
166 124 226 49.0 104
B2151 (6.52) (4.90) (8.90) (1.93) (4.09)
136.7 230.9 5.0 14.0 200 158 260 71.0 72.0 83.0 138 5.5 215 13.50 164 164 189
B2152 (5.38) (9.09) (0.197) (0.55) (7.86) (6.24) (10.24) (2.795) (2.834) (3.27) (5.43) (0.22) (8.465) (0.5315) (6.456) (6.459) (7.44)
234 192 294 117 172
B2153 (9.20) (7.58) (11.58) (4.61) (6.77)
(1) Dimension is for motor with M23 power connector. For motor with M40 power connector, add 18.6 (0.73 in.).
(2) Tolerance for this dimension is ±0.52 mm (±0.02 in.).
(3) Tolerance for this dimension is ±0.40 mm (±0.015 in.).
(4) Tolerance for this dimension is ±1.50 mm (±0.06 in.) static, ±0.13 mm (±0.005 in.) dynamic.
(5) Tolerance for this dimension is +0.430, -0.000 mm (+0.0169, -0.0000 in.).
65
Chapter 1
66
Dimensions are in mm (in.) Machine Mounting Dimensions
Chapter 1
EB
Pilot Diameter E T
Shaft, Pilot, and G
RDB-B290xx RDB-B410xx
Keyway Tolerances
GD
Shaft Runout (T.I.R.) 0.038 (0.0015)
Rotary Motion
AD
R
S Diameter Holes on
M Diameter Bolt Circle
Bulletin RDB-B290xx and RDB-B410xx Motor Dimensions
)
Motor
AD HD T LA (1) LD LE LB (2) D DB E (3) EB (4) M S N P (5) G GD F
Series
mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
RDB-
86.5 136 201 43.94 88.92
B2901 (3.40) (5.34) (7.92) (1.730) (3.540)
182.3 305.9 13.5 22.2 136 185 251 59.9 69.9 88.14 134.11 290 14.0 232.9 245.9 24.99 8.00 12.0
B2902 (7.18) (12.05) (0.53) (0.88) (5.36) (7.30) (9.90) (2.362) (2.755) (3.470) (5.280) (11.417) (0.551) (9.17) (9.68) (0.984) (0.315) (0.472)
186 235 301 124.7 170.69
B2903 (7.31) (9.25) (11.83) (4.910) (6.720)
105 164 230 40.39 114.05
B4101 (4.14) (6.46) (9.05) (1.590) (4.490)
256.3 432.1 17.8 25.4 174 233 300 69.9 79.9 83.82 167.89 410 17.5 333.9 350.0 29.99 8.00 12.0
B4102 (10.09) (17.01) (0.70) (1.00) (6.86) (9.18) (11.77) (2.755) (3.149) (3.300) (6.610) (16.142) (0.689) (13.14) (13.78) (1.181) (0.315) (0.472)
243 302 368 118.62 253.49
B4103 (9.58) (11.90) (14.49) (4.670) (9.980)
(1) Tolerance for this dimension is ±2.15 mm (±0.085 in.).
(2) Tolerance for this dimension is ±2.30 mm (±0.09 in.).
(3) Tolerance for this dimension is ±0.13 mm (±0.005 in.).
(4) Tolerance for this dimension is ±1.50 mm (±0.060 in.) static, ±0.05 mm (±0.002 in.) dynamic.
(5) Tolerance for this dimension is ±1.52 mm (±0.06 in.).
Power Connectors on
RDD-Series Motors RDB-B290xx RDB-B410xx
RDB-B29014,
RDB-B29016,
M23 Power Connector RDB-B29024, N/A
RDB-B29019,
RDB-B29034,
RDB-B29026
Motors are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions without tolerances are for reference.
Rotary Motion
67
Chapter 1
Chapter 1 Rotary Motion
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your motor. For questions regarding product
availability, contact your Allen-Bradley distributor.
RD B - B xxx x x - x B 7 2 AA
Factory Options
AA = Standard
Brake
2 = No brake
Connectors
7 = Circular (SpeedTec) DIN connector, right angle, 180° rotatable
Enclosure/Shaft
B = IP65 housing/Blind bore
Feedback
7 = Multi-turn, 2048 sin/cos, absolute encoder (EnDat protocol)
3 = Single-turn, 2048 sin/cos, absolute encoder (EnDat protocol)
Base Speed @ 440V (1)
4 = 200 rpm
5 = 250
6 = 375 rpm
8 = 625
9 = 750 rpm
C = 1500 rpm
Magnet Stacks (1)
1 = 1 stack
2 = 2 stacks
3 = 3 stacks
4 = 4 stacks
Frame Size - Bolt Circle Diameter (BCD)
215 = 215 mm
290 = 290 mm
410 = 410 mm
Voltage Class
B = 400V
Housing Type
B = Bearingless housing
Series
RD = Rotary direct drive servo motor
(1) Not all combinations are available. Only the configurations for rated speed and magnet stacks as listed in RDD-Series Direct Drive Motor Performance Specifications on
page 63 are available.
HPK-Series motors are available with high performance encoders with a choice of Single-turn (-S) or Multi-turn (-M)
high-resolution feedback.
• Up to 2 million counts per revolution for smooth performance.
• Single-turn encoder provides high-resolution absolute position feedback within one turn.
• Multi-turn encoder provides high-resolution absolute position feedback within 4096 turns.
System Combinations
For HPK-Series Motors and Refer to
Kinetix 7000 drives page 576
Motor Cat. No. Holding Torque Motor Cat. No. Holding Torque
HPK- Nm (lb-in) HPK- Nm (lb-in)
B/E1307C B/E1307E
B/E1308C B/E1308E
20 (177)
B/E1310C B/E1609E 20 (177)
B/E1613C B/E1611E
B/E1815C B/E1613E
48 (425)
B/E2010C B/E2010E 48 (425)
B2212C 102 (903)
EA L
Dimensions are in mm (in.)
Junction box rotates in 90° increments
and is shown in F3 mount (top) location.
Encoder S Diameter Holes on
Connector M Diameter Bolt Circle
LA
T HB
P
HD
Airflow
Clearance N HC
Required BD BE
H
AA AA K
B C E
B1 A
B2
BA BB BC C1 AB
AC
Motor K A AA AB AC B B1 B2 BA BB BC C C1 E BD BE
Series mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm
HPK-B/E (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.)
333 365 390 187 300
1307 (13.1) (14.3) (15.3) (7.36) (11.8)
12.0 216 108 260 279 371 403 428 154 226 95.0 89.0 57.0 110 91.0 338
1308 (0.47) (8.50) (4.25) (10.2) (10.9) (14.6) (15.8) (16.8) (6.06) (8.90) (3.74) (3.50) (2.24) (4.33) (3.58) (13.3)
403 435 462 257 369
1310 (15.8) (17.1) (18.1) (10.1) (14.5)
414 452 225 321
1609 N/A (16.3) (17.8) (8.86) 130 (12.6)
14.0 254 127 313 332 464 502 170 276 95.0 108 82.0 110 (5.12) 372
1611 N/A
(0.55) (10.0) (5.0) (12.3) (13.0) (18.2) (19.7) (6.69) (10.8) (3.74) (4.25) (3.23) (4.33) (14.6)
515 548 327 125 423
1613 N/A (20.2) (21.5) (12.8) (4.92) (16.6)
Motors are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
L AD
LD AE
Encoder
Connector
J1
Airflow
Clearance J2
Required BE
Motors are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
52.0 1116
(2.05) (43.9) Dimensions are in mm (in.)
Junction box rotates in 90° increments
and is shown in F3 mount (top) location. 16.0 350 16.0
(0.63) (13.8) (0.63)
Encoder
Connector
69.0
(2.72)
514
476 (20.2)
Airflow (18.7)
Clearance
Required
180
(7.09)
15.0
(0.59)
622 133 140 70 Ø 15.0
(24.5) (5.24) (5.51) (2.76) (0.59)
670 279
(26.4) (10.9)
174 420 65.0
(6.85) (16.5) (2.56) 350
(13.8)
Shaft Detail with Key
Shaft, Pilot, and
Keyway Tolerances HPK-B/E1815
20 x 12 x 110 Key 19.9
(0.78) Shaft Runout (T.I.R.) 0.06 (0.002)
Ø 70.0 Max Face Runout (T.I.R.) 0.13 (0.005)
(2.76)
Keyway Depth 73.90…74.50 (2.91…2.93)
Shaft Diameter Tolerances 62.5 74.5 Keyway Depth 62.00…62.50 (2.44…2.46)
HPK-B/E1815 (2.4) (2.9)
Ø 70.007…70.033 (2.7562…2.7572) Keyway Width 19.94…19.99 (0.785…0.787)
310
Dimensions are in mm (in.) (12.2)
250
1167 (9.84)
(45.9) 229
330
(9.02)
12.5 mm (0.5 in.) (13.0)
Conduit
Encoder
683
Connector
(26.9)
224
Airflow (8.82) 228
Clearance (8.98)
Required 472
(18.6)
87.0
(3.43)
Junction box rotates in 90° increments 395
and is shown in F1 mount (left side) location. (15.5)
Motor is also available in F2 mount (right side) location.
691
450
(27.2)
(17.7)
Airflow
Clearance
Required
200
(7.87)
19.0
(0.73)
654 146 170 Ø 19.0
(25.7) 318
(5.75) (6.69) (0.75)
(12.5)
705
397
(27.7)
(15.6)
203 420 82.0
(8.0) (16.5) (3.23)
Shaft, Pilot, and
Shaft Detail with Key Keyway Tolerances HPK-B/E2010
22 x 14 x 140 Key 22.0 Shaft Runout (T.I.R.) 0.06 (0.002)
(0.86)
Ø 80.0 Max Face Runout (T.I.R.) 0.13 (0.005)
(3.15) Keyway Depth 84.50…85.10 (3.33…3.35)
Shaft Diameter Tolerances 85.0 Keyway Depth 70.60…71.10 (2.78…2.80)
71.0
HPK-B/E2010 (2.8) (3.3) Keyway Width 21.95…22.00 (0.864…0.866)
Ø 80.010…80.028 (3.1500…3.1507)
244
447 (9.61)
Airflow (17.6)
Clearance
Required
161
435
Junction box rotates in 90° increments (6.34) (17.1)
and is shown in F1 mount (left side) location.
Motor is also available in F2 mount (right side) location.
Airflow 738
Clearance 447 (29.0)
Required (17.6)
588
225
(23.1)
(8.8)
140 23.0
806 (5.50) (0.91) 86.0
(3.40) Ø 19.0
(31.7) 156
356 (0.75)
864 (6.13)
(34.0) (14.0)
254 95.0 445
(10.0) (3.75) (17.5)
585 244
Airflow (23.0) (9.61)
Clearance
Required
161
(6.35) 445
Junction box rotates in 90° increments
(17.5)
and is shown in F1 mount (left side) location.
Motor is also available in F2 mount (right side) location.
Motors are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
HPK-Series motors are capable of operating with the maximum radial or maximum axial shaft loads listed in the following
tables. Radial loads listed are applied in the middle of the shaft extension. The tables starting below represent an L10
bearing fatigue life of 10,000 hours. This 10,000-hour life does not account for possible application-specific life reduction
that may occur due to bearing grease contamination from external sources. Maximum operating speed is limited by motor
winding.
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your motor. For questions regarding product
availability, contact your Allen-Bradley distributor.
HPK - x xxxx x -x x x x x A
Factory Options
A = Standard
Mounting Type/Shaft Key
A = IEC metric, free mounting holes (type FF), foot mount and flange mount/Keyed shaft (1)
B = IEC metric, free mounting holes (type FF), foot mount only/Keyed shaft (2)
Brake
2 = No brake
4 = Holding brake 380…460V AC
Connections
4 = Feedback - right angle, 180° rotatable
Power - junction box
Blower/Junction Box Location
A = Inline blower, F3 junction box (no brake only)
B = Top-mounted blower, F1 junction box (brake only)
C = Top-mounted blower, F2 junction box (brake only)
Feedback
M = Multi-turn, 1024 sin/cos, absolute encoder (Hiperface protocol)
S = Single-turn, 1024 sin/cos, absolute encoder (Hiperface protocol)
Base Speed (3)
C = 1500 rpm
E = 3000 rpm
Frame Size (3)
1307 1609 1815 2510
1308 1611 2010
1310 1613 2212
Voltage Class
B = 460V
E = 400V
Series
HPK = HPK-Series asynchronous servo motors
TL-Series Motors
The TL-Series motors are low-inertia high-performance servo motors featuring metric and NEMA frame sizes. They
combine a compact size with a high torque density afforded by their superior stator design. The result is a package that
provides substantial power in a small footprint.
TL-Series motors are available with high-resolution or industry standard incremental encoder feedback.
• High-resolution, high performance encoders providing multi-turn absolute position feedback (131,072
counts/revolution) for smooth performance.
• Industry standard incremental encoder feedback (2,000 counts/revolution) applies to Bulletin TLY motors.
TL-Series motors are equipped with either threaded or rectangular plastic connectors.
TL-Axxxx Motors
TLY/TL-A25xx
TL-SSN-3 19.8 (0.78) 30 (1.18) 5 (0.20)
TLY-A3xx
Transition plates provide a means of retrofitting an existing N-Series motor with a TL-Series (Bulletin TLY) NEMA
motor. In most applications, the TL-Series (Bulletin TLY) NEMA motor will be physically smaller, but will deliver the
same torque rating as the N-Series motor it is replacing. Transition plates are not available for the N-56xx motors. Select
your transition plate catalog number from the table below.
(1) Refer to TL-Series Motor Weight Specifications on page 83 for Brake Motor Weight.
(2) The TLY/TL-A110 and TL-A410 motors are available only in metric frame sizes. All other motors are available in metric and NEMA frame sizes.
(3) Applies to TLY-AxxxT-H motors with incremental feedback. The TLY/TL-AxxxP-B motors with absolute high-resolution encoders are rated at 5000 rpm.
(1) Refer to TL-Series Motor Weight Specifications on page 83 for Brake Motor Weight.
(2) The TLY/TL-A110 and TL-A410 motors are available only in metric frame sizes. All other motors are available in metric and NEMA frame sizes.
(3) Applies to TLY-AxxxT-H motors with incremental feedback. The TLY/TL-AxxxP-B motors with absolute high-resolution encoders are rated at 5000 rpm.
System Combinations
Feedback Option
For TL-Series Motors and Bulletin Refer to
Compatibility
Kinetix 6000 (230V) drives Incremental only page 557
Kinetix 2000 drives High-resolution or Incremental page 570
TLY
Kinetix 300 (240V) drives High-resolution or Incremental page 615
High-resolution or Incremental page 621
Kinetix 3 drives
TL High-resolution only page 626
Ultra3000/5000 (230V) drives TLY Incremental only page 662
1000 (39.4)
±50 (1.97)
Shaft Detail with Key Shaft Diameter Tolerances
TLY/TL-A110, -A120, and -A130 Motors: TLY/TL-A2530 and -A2540 Motors:
G Ø 7.991…8.000 (0.3146…0.3150) Ø 15.989…16.000 (0.6295…0.6299)
F
Bulletin TLY TLY/TL-A220 and -A230 Motors: TLY-A310 Motors:
Connectors Ø 11.989…12.000 (0.4720…0.4724) Ø 15.989…16.000 (0.6295…0.6299)
TL-A410 Motors:
Feedback Ø 21.987…22.000 (0.8656…0.8661)
TLY/TL-A110, -A120, and -A130 Motors
3 +0, -0.025 x 3 +0, -0.025 x 15 Key Connector Power/Brake
TLY/TL-A220 and -A230 Motors Connector
Bulletin TLY-Axxxxx-xx6xAA or TL-Axxxxx-Bx3xAA Motor Dimensions
Feedback Power
Connector Connector
Brake
Connector
(option)
Bulletin TLY-Axxxxx-xx6xAA or TL-Axxxxx-Bx3xAA Motor Dimensions
85
Chapter 1
86
Chapter 1
L P
AC LB L-LB Pilot Diameter Tolerances
T TLY-A120 and -A130 Motors:
Key (supplied) Ø 21.979…22.000 (0.8653…0.8661)
TLY-A220 and -A230 Motors:
Ø 38.075…38.100 (1.4990…1.5000)
D Shaft Diameter N TLY-A2530 and -A2540 Motors:
HD Ø 72.99…73.02 (2.874…2.875)
AD
Optional Shaft Seal
LA Refer to page 81
LE
for TL-Series motor
BE shaft seal kit information.
Bulletin TLY-Axxxxx-Hx6xAN NEMA Motor Dimensions
1000 (39.4)
Shaft Detail with Key ±50 (1.97) Shaft Diameter Tolerances
TL-Series (Bulletin TLY) NEMA Motor Dimensions
NEMA motor flanges and shafts are designed to inch dimensions. Other frame areas are designed to metric dimensions. Conversions are approximate values.
87
Chapter 1
Chapter 1 Rotary Motion
TL-Series motors are capable of operating with the maximum radial or maximum axial shaft loads listed in the following
tables. Radial loads listed are applied in the middle of the shaft extension. The tables below represent an L10 bearing fatigue
life of 20,000 hours. This 20,000-hour life does not account for possible application-specific life reduction that may occur
due to bearing grease contamination from external sources. Maximum operating speed is limited by motor winding.
For TL-Series connector kit catalog numbers, refer to 2090-Series Motor-end Cable Connector Kits on page 424.
Rated Speed - The operating speed of the drive and motor combination at which approximately 70% of continuous rated
torque (To) can be developed. This point is defined with the motor at 25 °C (77 °F).
Rated Operation Area - The boundary of the torque-speed curve where the motor and controller combination may
operate on a servo basis without exceeding the RMS rating of either.
Intermittent Operation Area - The boundary of the torque-speed curve where the motor and controller combination may
operate in acceleration/deceleration mode without exceeding peak rating of either, provided that the duty cycle RMS
continuous torque limit is not exceeded.
2 2 2 2
RMSTorque = (Tpa ) (t 1) + (Tss ) (t 2) + (Tpd ) (t 3) + (Tr ) (t 4)
t1 + t2 + t3 + t4
Continuous Current - The rated current of a motor with windings at a rated temperature and an ambient temperature of
40 °C (104 °F).
Peak Current - The amount of current that can be applied to the motor without causing damage to the motor.
Mechanical Time Constant - The time required for the motor to reach 63% of its final speed when a step voltage is
applied.
Electrical Time Constant - The time required for the motor to reach 63% of its rated current.
Maximum Ambient Temperature - The maximum environmental temperature in which the motor can be operated at
rated loads without exceeding its insulation-type temperature rise limits.
Insulation Class - The designation of the operating temperature limits for motor insulation materials.
Thermal Time Constant - The time required for the motor windings to reach 63% of continuous temperature rise with
constant watts loss.
Torque Constant - The amount of torque developed for one ampere of motor current at the stated motor temperature.
Voltage Constant - The value of the generated voltage at a specified speed when the rotor is moved mechanically in the
magnetic field.
Inductance - The winding inductance measured by a step input of zero impedance voltage applied to the locked rotor.
Rotor Polar Moment of Inertia - The moment of inertia about the axis of rotation.
Motor Weight - The approximate weight of the complete motor (including brake, if supplied) less the weight of options.
Balance - The compensation of rotor weight distribution to reduce vibrational resonance. Motors are factory balanced
under running speeds.
Linear Motion
Use this chapter to become familiar with the Kinetix Motion Control linear motors and actuators and select the linear
motion components required for your application. To compare features from one family of linear motion components to
another, refer to Linear Servo Motors on page 11 and Linear Actuators on page 12.
Topic Page
Environmental Specifications
MP-Series LDC-Series and
MP-Series and TL-Series Electric Cylinders
Attribute Integrated Linear Stages LDL-Series
Bulletin MPAS Bulletin MPMA Bulletin MPAR Bulletin TLAR Bulletin MPAI Linear Motors
Environmental Ratings
IP Rating Dust Protection Liquid Protection Actuator/Motor
Objects larger than
IP30 No protection from liquids. Bulletin MPAS and MPMA
2.5 mm (0.098 in.)
Objects larger than
IP40
1.0 mm (0.039 in.)
No protection from liquids. Bulletin MPAR and TLAR (1)
IP65 Protected against low-pressure jets of water from all directions. LDC-Series and LDL-Series
IP66 Total protection Protected against strong jets of water. Bulletin MPAR (2) (3)
from dust
IP67 Protected against the effects of temporary liquid immersion. Bulletin MPAI (3)
(1) Applies to complete unit, including rod-end seal and breather port.
(2) Applies to electronic components.
(3) Requires use of Bulletin 2090 environmentally sealed cable connectors.
The brakes are not designed for stopping an actuator in motion. Servo drive inputs should be used to stop carriage/rod
cylinder motion before the brake is activated. The recommended method of stopping motion is to command the servo
drive to decelerate the carriage/rod cylinder to a complete stop and engage the brake only after the carriage/rod cylinder
has stopped.
If system main power fails, the brakes can withstand use as stopping brakes. However, use of the brakes as stopping brakes
can create mechanical backlash that is potentially damaging to the system, increases brake pad wear and reduces brake life.
The brakes are not designed nor are they intended to be used as a safety device.
A separate power source is required to disengage the brake. This power source can be controlled by the linear stage controls,
in addition to manual operator controls. Electrical arcing may occur at the relay contacts until the brake power dissipates. A
customer supplied diode or metal oxide varistor (MOV) is recommended to prevent arcing. Use of an MOV can also
reduce the time to mechanically engage the brake.
Customer Supplied
Diode or MOV Arc Suppressor (1)
BR-
DC Power
to Brake
BR+
Brake Relay
Actuator with MP-Series or TL-Series Motor
MP-Series servo motor with linear
(ballscrew) stage is shown.
(1) Kinetix 2000, Kinetix 6000, Kinetix 6200, Kinetix 6500, and Kinetix 7000 servo drives provide motor/actuator brake relay outputs and supply an MOV arc suppressor, so
customer-supplied arc suppressor is not required unless the coil current of the brake is greater than the maximum brake current rating of the drive relay output.
MPAS-A/B6xxx1-V05SxA
MPAS-A/B6xxx2-V20SxA Ballscrew with
MPAS-A/B8xxx1-V05SxA ±60 µm 60 µm + 167 µm/m
absolute multi-turn
MPAS-A/B8xxx2-V20SxA (±0.002 in.) (0.002 in. + 0.002 in./ft)
rotary encoder
MPAS-A/B9xxx1-V05SxA
MPAS-A/B9xxx2-V20SxA 10 µm + 50 µm/m 10 µm + 50 µm/m
MPAS-A6xxxB-ALMx2C
MPAS-A8xxxE-ALMx2C Linear Motor with ±15 µm 100 µm + 20 µm/m
MPAS-B8xxxF-ALMx2C incremental linear (±0.0005 in.) (0.004 in. + 0.0002 in./ft)
MPAS-A9xxxK-ALMx2C encoder
MPAS-B9xxxL-ALMx2C
(1) Measured at 20 °C (68 °F).
The static moment and force ratings shown in the performance specifications tables are the maximum permissible values
possible before permanent damage to the linear stage can occur. To determine the estimated L10 bearing and ballscrew life
of MP-Series Integrated Linear Stages, use Motion Analyzer software, version 4.4 or later.
Pitch Moment Load
Roll Moment Load
Yaw Moment Load
Reverse
Radial Force Load Radial Force Load
Lateral Force Load
Cont. Peak Max Static Loads (1) Max Static Moment Loads (1)
Linear Stage Screw Stroke Velocity, Stall Stall
Cat. No. Lead Length max Reverse Pitch Yaw Roll
Force Force Radial Lateral
MPAS- mm (in.) mm (in.) mm/s (in./s) Radial Nm Nm Nm
N (lb) N (lb) N (lb) N (lb)
N (lb) (lb-ft) (lb-ft) (lb-ft)
A6xxx1-V05SxA 5.0 (0.2) 120…660 200 (7.9) 521 (117) 1212 (272)
A6xxx2-V20SxA 20.0 (0.8) (4.7…26.0) 1124 (44.3) 462 (104) 968 (218)
A6xxxB-ALMO2C 5506 2367 2753 195 227 92
N/A 105 (24) 359 (81) (1238) (532) (619) (144) (167) (68)
(no cover) 120…1140 5000
A6xxxB-ALMS2C (4.7…44.9) (196.9)
N/A 83 (19) 312 (70)
(covered)
(1) Values apply to bearing ratings only. Contact your Rockwell Automation sales representative for structural considerations.
Cont. Peak Max Static Loads (1) Max Static Moment Loads (1)
Linear Stage Screw Stroke Velocity, Stall Stall
Cat. No. Lead Length max Reverse Pitch Yaw Roll
Force Force Radial Lateral
MPAS- mm (in.) mm (in.) mm/s (in./s) Radial Nm Nm Nm
N (lb) N (lb) N (lb) N (lb)
N (lb) (lb-ft) (lb-ft) (lb-ft)
120…780 200 (7.9)
(4.7…30.7)
521 1212
A8xxx1-V05SxA 5.0 (0.2) 900 (35.4) 176 (6.9) (117) (273)
1020 (40.1) 143 (5.6)
9365 4027 4683 336 391 258
120…660 1124 (44.3) (2105) (905) (1053) (248) (288) (190)
(4.7…26.0)
780 (30.7) 889 (35.0) 462 968
A8xxx2-V20SxA 20.0 (0.8) (104) (218)
900 (35.4) 715 (28.1)
1020 (40.1) 582 (22.9)
A8xxxE-ALMO2C 189 456
N/A
(no cover) 140…1940 (43) (103) 9100 4100 4700 402 492 245
5000 (196.9)
A8xxxE-ALMS2C (5.5…76.4) 159 399 (2046) (922) (1057) (297) (363) (181)
N/A
(covered) (36) (90)
(1) Values apply to bearing ratings only. Contact your Rockwell Automation sales representative for structural considerations.
Cont. Peak Max Static Loads (1) Max Static Moment Loads (1)
Linear Stage Screw Stroke Velocity, Stall Stall
Cat. No. Lead Length max Force Force Reverse Lateral Pitch Yaw Roll
Radial
MPAS- mm (in.) mm (in.) mm/s (in./s) Radial Nm Nm Nm
N (lb) N (lb) N (lb) N (lb)
N (lb) (lb-ft) (lb-ft) (lb-ft)
120…780 200 (7.9)
(4.7…30.7)
521 1212
A9xxx1-V05SxA 5.0 (0.2) 900 (35.4) 176 (6.9) (117) (273)
1020 (40.1) 143 (5.6)
13,282 5711 6641 477 555 468
120…660 1124 (44.3) (2986) (1284) (1493) (352) (409) (345)
(4.7…26.0)
System Combinations
For MP-Series Integrated Linear Stages and Refer to
Kinetix 6000 (230V) drives page 669
Kinetix 2000 (230V) drives page 698
Kinetix 300 (240V) drives page 718
Kinetix 3 (240V) drives page 731
Ultra3000 (230V) drives page 744
System Combinations
For MP-Series Integrated Linear Stages and Refer to
Kinetix 6000 (460V) drives and page 672
Kinetix 6200 and Kinetix 6500 (460V) drives
Kinetix 300 (480V) drives page 720
Ultra3000 (460V) drives page 748
MP-Series Integrated Linear Stage Standard Stroke Length and Weight Specifications
MP-Series Integrated Linear Stages, Ballscrew (150 mm frame size)
Standard Stroke Standard Stroke
Linear Stage Cat. No. Weight, approx. Linear Stage Cat. No. Weight, approx.
Lengths Lengths
MPAS- kg (lb) MPAS- kg (lb)
mm (in.) mm (in.)
120 (4.7) 14.5 (32.0) 120 (4.7) 13.9 (30.5)
180 (7.1) 15.4 (33.9) 180 (7.1) 14.7 (32.4)
240 (9.5) 16.3 (35.8) 240 (9.5) 15.6 (34.3)
A/B6xxx2-V20S2A A/B6xxx1-V05S2A
20 mm/rev 300 (11.8) 17.1 (37.7) 5 mm/rev 300 (11.8) 16.4 (36.2)
(0.8 in./rev) 360 (14.2) 18.0 (39.6) (0.2 in./rev) 360 (14.2) 17.3 (38.1)
Ballscrew without brake Ballscrew without brake
420 (16.5) 18.9 (41.5) 420 (16.5) 18.2 (40.0)
540 (21.3) 20.6 (45.4) 540 (21.3) 19.9 (43.7)
660 (26.0) 22.4 (49.2) 660 (26.0) 21.6 (47.5)
120 (4.7) 15.0 (33.0) 120 (4.7) 14.3 (31.5)
180 (7.1) 15.9 (34.9) 180 (7.1) 15.2 (33.4)
240 (9.5) 16.7 (36.8) 240 (9.5) 16.0 (35.3)
A/B6xxx2-V20S4A A/B6xxx1-V05S4A
20 mm/rev 300 (11.8) 17.6 (38.7) 5 mm/rev 300 (11.8) 16.9 (37.2)
(0.8 in./rev) 360 (14.2) 18.5 (40.6) (0.2 in./rev) 360 (14.2) 17.8 (39.1)
Ballscrew with brake Ballscrew with brake
420 (16.5) 19.3 (42.5) 420 (16.5) 18.6 (40.9)
540 (21.3) 21.1 (46.4) 540 (21.3) 20.3 (44.7)
660 (26.0) 22.8 (50.2) 660 (26.0) 22.1 (48.5)
A/B8xxx2-V20S2A 360 (14.2) 20.4 (44.8) A/B8xxx1-V05S2A 360 (14.2) 19.8 (43.5)
20 mm/rev 5 mm/rev
420 (16.5) 21.4 (47.0) 420 (16.5) 20.7 (45.6)
(0.8 in./rev) (0.2 in./rev)
Ballscrew without brake 540 (21.3) 23.3 (51.3) Ballscrew without brake 540 (21.3) 22.7 (49.9)
660 (26.0) 25.2 (55.5) 660 (26.0) 24.6 (54.2)
780 (30.7) 27.2 (59.8) 780 (30.7) 26.6 (58.5)
900 (35.4) 29.1 (64.1) 900 (35.4) 28.5 (62.7)
1020 (40.2) 31.1 (68.4) 1020 (40.2) 30.5 (67.1)
120 (4.7) 16.9 (37.2) 120 (4.7) 16.3 (35.9)
180 (7.1) 17.9 (39.4) 180 (7.1) 17.3 (38.0)
240 (9.5) 18.9 (41.5) 240 (9.5) 18.3 (40.2)
300 (11.8) 19.9 (43.7) 300 (11.8) 19.2 (42.3)
A/B8xxx2-V20S4A 360 (14.2) 20.8 (45.8) A/B8xxx1-V05S4A 360 (14.2) 20.2 (44.5)
20 mm/rev 420 (16.5) 21.8 (48.0) 5 mm/rev 420 (16.5) 21.2 (46.6)
(0.8 in./rev) (0.2 in./rev)
Ballscrew with brake 540 (21.3) 23.8 (52.3) Ballscrew with brake 540 (21.3) 23.1 (50.9)
660 (26.0) 25.7 (56.5) 660 (26.0) 25.1 (55.2)
780 (30.7) 27.7 (60.8) 780 (30.7) 27.0 (59.5)
900 (35.4) 29.6 (65.1) 900 (35.4) 29.0 (63.8)
1020 (40.2) 31.6 (69.4) 1020 (40.2) 30.9 (68.0)
A/B9xxx2-V20S2A 360 (14.2) 24.9 (54.8) A/B9xxx1-V05S2A 360 (14.2) 24.3 (53.4)
20 mm/rev 5 mm/rev
420 (16.5) 26.2 (57.6) 420 (16.5) 25.6 (56.2)
(0.8 in./rev) (0.2 in./rev)
Ballscrew without brake 540 (21.3) 28.7 (63.2) Ballscrew without brake 540 (21.3) 28.1 (61.8)
660 (26.0) 31.3 (68.8) 660 (26.0) 30.6 (67.4)
780 (30.7) 33.8 (74.3) 780 (30.7) 33.2 (73.0)
900 (35.4) 36.3 (79.9) 900 (35.4) 35.7 (78.6)
1020 (40.2) 38.9 (85.5) 1020 (40.2) 38.2 (84.1)
120 (4.7) 20.3 (44.6) 120 (4.7) 19.7 (43.3)
180 (7.1) 21.5 (47.4) 180 (7.1) 20.9 (46.0)
240 (9.5) 22.8 (50.2) 240 (9.5) 22.2 (48.8)
300 (11.8) 24.1 (53.0) 300 (11.8) 23.5 (51.6)
A/B9xxx2-V20S4A 360 (14.2) 25.4 (55.8) A/B9xxx1-V05S4A 360 (14.2) 24.7 (54.4)
20 mm/rev 420 (16.5) 26.6 (58.6) 5 mm/rev 420 (16.5) 26.0 (57.2)
(0.8 in./rev) (0.2 in./rev)
Ballscrew with brake 540 (21.3) 29.2 (64.2) Ballscrew with brake 540 (21.3) 28.5 (62.8)
660 (26.0) 31.7 (69.7) 660 (26.0) 31.1 (68.4)
780 (30.7) 34.2 (75.3) 780 (30.7) 33.6 (74.0)
900 (35.4) 36.8 (80.9) 900 (35.4) 36.2 (79.6)
1020 (40.2) 39.3 (86.5) 1020 (40.2) 38.7 (85.1)
165 167
(6.50) (6.57)
120 (4.72)
(4X) Ø 7.0 (0.28) 45.0 (1.80) Thru 54.5
130 Toe Clamp/Tee-nut Spacing
Pilot Hole (2.15)
(5.12)
Dimensions are in mm (in.) (4X) M10 x 1.5-6H Thru (2 per end cap)
Access point for lubricating linear bearings.
Provision to use lifting hooks (not provided).
See Detail A 46.8
(1.84) (OAL) Overall Length
181.5
(7.15) (S) Stage Length
125.5
(4.94)
8.5
(0.33) 123.8 Ground Screw 30.0
0.025 / 300 x 300 (0.001 / 12.0 x 12.0)
92.0 M5 x 0.8-6H Flatness requirement for the surface
(4.87) (1.18) Ø 13.0 (0.51) Thru
(3.62) that this stage is being mounted to.
32.0 7.6 Access Point to Lubricate
(1.26) Detail A (0.30) Dimension OAL measures to the head of Ballscrew Nut
150 9.3 (0.37) the screws on the motor end cap.
(5.90) Depth, max
Actuators are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
Actuators are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
6.5 (0.26)
Depth, max (2X) Ø 5.5 (0.22) Thru 56.4 120 (4.72)
T- Nut Toe Clamp/Tee-nut Spacing
Mount to base using Pilot Hole (2.22)
M6 x 1.0 hardware (optional accessory).
Toe Clamp is standard for
covered stages. Mount to base (4X) 9/16-12 UNC Thru (2 per end cap)
using M6 x 1.0 socket cap screw. Dimensions are in mm (in.) Access point for lubricating linear bearings.
Provision to use lifting hooks (not provided).
See Detail A
(OAL) Overall Length
281
(11.06) (S) Stage Length
46.8
(1.84) 105.4
(4.15)
8.5
(0.33) Ground Screw
30.0 0.025 / 300 x 300 (0.001 / 12.0 x 12.0)
M5 x 0.8-6H Ø 13.0 (0.51) Thru
172.2 (1.18) Flatness requirement for the surface
38.3 Dimension OAL measures to the head of Access Point to Lubricate
(6.78) that this stage is being mounted to.
(1.51) the screws on the motor end cap. Ballscrew Nut
249
(9.8)
Actuators are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
167
(6.57)
120 (4.72)
130 104.5 Toe Clamp/
(4X) Ø 7.0 (0.28) 45.0 (1.80) Thru
(5.12) (4.11) Tee-nut Spacing
Pilot Hole
See Detail A (4X) M10 x 1.5-6H Thru (2 per end cap) Dimensions are in mm (in.)
Access point for lubricating linear bearings.
238.6 Provision to use lifting hooks (not provided).
46.8
(9.40)
(1.84) 181.5 Ground Screw (OAL) Overall Length
(7.15) M5 x 0.8-6H
123.8
(4.88)
8.5
(0.33) 30.0 0.025 / 300 x 300 (0.001 / 12.0 x 12.0)
92.0
(1.18) Flatness requirement for the surface
(3.62) (CE) Cable Extensions
32.0 From End of Cable Carrier that this stage is being mounted to.
(1.26) 150
Detail A 7.6 Bracket located ±51 (2.0)
(5.9)
(0.30) from center of travel.
9.3 (0.37)
Depth, max
Linear Stage Cat. No. OAL CE Linear Stage Cat. No. OAL CE
MPAS- mm (in.) mm (in.) MPAS- mm (in.) mm (in.)
A6012B-ALMx2C 570 (22.4) 1218 (48.0) A6054B-ALMx2C 990 (39.0) 1018 (40.0)
A6018B-ALMx2C 630 (24.8) 1193 (47.0) A6066B-ALMx2C 1110 (43.7) 943 (37.0)
A6024B-ALMx2C 690 (27.2) 1168 (46.0) A6078B-ALMx2C 1230 (48.4) 893 (35.0)
A6030B-ALMx2C 750 (29.5) 1118 (44.0) A6090B-ALMx2C 1350 (53.1) 818 (32.0)
A6036B-ALMx2C 810 (31.9) 1093 (43.0) A6102B-ALMx2C 1470 (57.9) 1768 (70.0)
A6042B-ALMx2C 870 (34.3) 1068 (42.0) A6114B-ALMx2C 1590 (62.6) 1718 (68.0)
Actuators are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
215.7
(8.49) 216.7
166.6 (8.53)
(6.56)
120 (4.72)
120 116.4 Toe Clamp/
(4.72) (4.58) Square Nut Spacing
Dimensions are in mm (in.)
Ø 5.8 (0.23) Thru
Ø 9.7 (0.38) Thru 14.2 (0.56)
See Detail A (4X) M10 x 1.5-6H Thru (2 per end cap)
Access point for lubricating linear bearings.
288.9 Provision to use lifting hooks (not provided).
46.8 (11.38)
(1.84) 232
(9.13) (OAL) Overall Length
Ground Screw
M5 x 0.8-6H 105.5
(4.15)
Actuators are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
264.7
(10.42) 265.7
208.6
(10.46)
(8.21)
Actuators are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your actuator. For questions regarding product
availability, contact your Allen-Bradley distributor.
MP AS - x x xxx x - x xx x x x
Cable
A = No cable track module (ballscrew only)
C = Cable track module with IP67 intercontec connectors (direct drive only)
Brake
2 = No brake
4 = 24V DC brake (ballscrew only)
Cover
S = Covered with strip seals (IP30 protection)
O = Open (direct drive only)
Screw Lead/Motor Type
05 = 5.0 mm/rev (0.19 in./rev) ballscrew with rotary motor
20 = 20.0 mm/rev (0.79 in./rev) ballscrew with rotary motor
LM = Linear motor (direct drive only)
Feedback
V = Multi-turn high-resolution encoder (absolute feedback) 128 cycle/rev. (ballscrew only)
A = 5 micron resolution incremental magnetic linear encoder (direct drive only)
Mechanical Drive/Motor Type
1 = Ballscrew/MPLS-x210E-V 2 = Ballscrew/MPLS-x220H-V
B = Direct Drive/6-frame, 230V K = Direct Drive/9-frame, 230V
E = Direct Drive/8-frame, 230V L = Direct Drive/9-frame, 460V
F = Direct Drive/8-frame, 460V
Stroke Length (1)
xxx = xxx mm x 10
Frame Size (2)
6 = 150 mm base width
8 = 200 mm base width
9 = 250 mm base width
Voltage Class
A = 200V
B = 400V
Actuator Type
AS = Actuator, linear stage
Actuator Series
MP = MP-Series
(1) For 6-frame direct-drive linear stages, variable xxx (mm stroke x 10) is 012, 018, 024, 030, 036, 042, 054, 066, 078, 090, 102, or 114.
For 8 and 9-frame direct-drive linear stages, variable xxx (mm stroke x 10) is 014, 020, 026, 032, 038, 044, 056, 068, 080, 092, 104, 128, 152, 176, or 194.
For 6-frame ballscrew linear stages, variable xxx (mm stroke x 10) is 012, 018, 024, 030, 036, 042, 054, or 066.
For 8 and 9-frame ballscrew linear stages, variable xxx (mm stroke x 10) is 012, 018, 024, 030, 036, 042, 054, 066, 078, 090, or 102.
(2) The 150 mm (6-frame) linear stages are available in ballscrew (230/460V) and direct drive (230V only).
The 200 mm (8-frame) linear stages are available in ballscrew and direct drive (230/460V).
The 250 mm (9-frame) linear stages are available in ballscrew and direct drive (230/460V).
Refer to Accessory Kits for Single-axis Direct-drive Linear Stages on page 94 for accessory kit descriptions and catalog
numbers.
Refer to Accessory Kits for Single-axis Ballscrew Linear Stages on page 95 for accessory kit descriptions and catalog
numbers.
The Bulletin MPMA multi-axis stages are based on the individual Bulletin MPAS stages, so the Bulletin MPAS
force-velocity system performance specifications also apply to the Bulletin MPMA stages. For the Bulletin MPAS linear
stage performance specifications with compatible servo drives, refer to Linear Motion System Combinations, beginning on
page 667.
Bulletin MPMA multi-axis stages are comprised of custom Bulletin MPAS stages. This is due to the different cable
management requirements for stacked-stage assemblies. Additionally, the Bulletin MPAS individual stage identifier
embedded in the Bulletin MPMA catalog number does not correspond directly to the Bulletin MPAS catalog number used
in the system combinations.
Follow this example to determine the Bulletin MPAS stages for MPMA-AABC0C0A0-S1C multi-axis stages:
• Replace the Voltage Rating designator (x) with A (230V) or B (460V).
• Replace the Mechanical Drive/Motor Type designator.
– Replace (K/L) with K if 230V or L if 460V
– Replace (E/F) with E if 230V or F if 460V
• Replace the Cable designator (x), with the direct-drive standard C option.
• In this example: X-axis = MPAS-x9xxxK/L-ALMS2 and Y-axis = MPAS-x8xxxE/F-ALMS2.
– X-axis stage = MPAS-A9xxxK-ALMS2C
– Y-axis stage = MPAS-A8xxxE-ALMS2C
Follow this example to determine the Bulletin MPAS stages for MPMA-BAPB8B8A0-S1C multi-axis stages:
• Replace the Voltage Rating designator (x) with A (230V) or B (460V).
• Holding brake (4) or no brake (2) option does not affect system performance.
• In this example: X-axis = MPAS-x8xxx2-V20S2x and Y-axis = MPAS-x8xxx2-V20S2x.
– X-axis stage = MPAS-B8xxx2-V20SxA
– Y-axis stage = MPAS-B8xxx2-V20SxA
These specifications apply to center stacked X/Y stages with 250 mm frame linear
motor driven X-axis and 200 mm frame linear motor driven Y-axis. Maximum
payload is 15 kg (33.1 lb). For heavier loads, contact your Rockwell Automation
sales representative.
TU/2
See Detail A
65.4
(2.58)
86.1 248.7
(3.39) (9.79)
130.8 339
Base (13.35) Base
(5.15)
Carriage 172.2
(6.78)
B
104.1
(4.10)
117.7
(4.63)
TU/2
(4X) M8 X 1.25-6H 12.0 (0.47) (4X) M10 x 1.5-6H Thru (2 per end cap)
(4X) Ø 6.8 (0.27) 45.4 (1.79) Thru Access point for linear bearing
25.4 lubrication.
Secondary
Dimensions are in mm (in.) (1.00)
3.35 Secondary is not centered Bumper Travel
(0.132) on base carriage.
(4X) M10 x 1.5-6H Thru (2 per end cap) Detail A
Access point for linear bearing 6.5 max
lubrication. (0.26)
45.4 210.9
Ground Screw (1.79) (8.30) 5.6 min
(M5 x 0.8-6H) (0.22)
Quantity C
Mount to base using M6 x 1.0 hardware
at 120 mm spacing and the tee-nut bar
shipped with multi-axis stage.
Base 0.025 / 300 x 300 (0.001 / 12.0 x 12.0)
A Flatness requirement for assembly
mounting surface.
MPMA-xABxxxxxx-xxx Dimensions
A TL B TU C
Multi-axis Linear Stage Stage Length Travel Stage Length Travel Mounting Locations
Cat. No. (X-axis) (X-axis) (Y-axis) (Y-axis) (X-axis)
mm (in.) mm (in.) mm (in.) mm (in.) Qty
MPMA-AABC0C0A0-S1C 641 (25.2) 200 (7.9) 641 (25.2) 200 (7.9) 10
MPMA-AABC6C6A0-S1C 701 (27.6) 260 (10.2) 701 (27.6) 260 (10.2)
12
MPMA-AABD2D2A0-S1C 761 (30.0) 320 (12.6) 761 (30.0) 320 (12.6)
MPMA-AABD8D8A0-S1C 821 (32.3) 380 (15.0) 821 (32.3) 380 (15.0)
14
MPMA-AABE4E4A0-S1C 881 (34.7) 440 (17.3) 881 (34.7) 440 (17.3)
MPMA-AABF6F6A0-S1C 1001 (39.4) 560 (22.0) 1001 (39.4) 560 (22.0) 16
MPMA-BABC0C0A0-S1C 641 (25.2) 200 (7.9) 641 (25.2) 200 (7.9) 10
MPMA-BABC6C6A0-S1C 701 (27.6) 260 (10.2) 701 (27.6) 260 (10.2)
12
MPMA-BABD2D2A0-S1C 761 (30.0) 320 (12.6) 761 (30.0) 320 (12.6)
MPMA-BABD8D8A0-S1C 821 (32.3) 380 (15.0) 821 (32.3) 380 (15.0)
14
MPMA-BABE4E4A0-S1C 881 (34.7) 440 (17.3) 881 (34.7) 440 (17.3)
MPMA-BABF6F6A0-S1C 1001 (39.4) 560 (22.0) 1001 (39.4) 560 (22.0) 16
Actuators are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
These specifications apply to center stacked X/Y stages with 250 mm frame linear
motor driven X-axis and 250 mm frame linear motor driven Y-axis. Maximum
payload is 20 kg (44.0 lb). For heavier loads, contact your Rockwell Automation
sales representative.
65.4
(2.57) 339
(13.35) 86.1 248.7
Carriage (3.39) (9.79)
130.8
Base B Base
(5.15) 172.2
(6.78)
104.1
(4.10)
117.7
(4.63)
TU/2
Detail A
6.5 max
(0.26)
223.6
Ground Screw (8.80) 5.6 min
(M5 x 0.8-6H) (0.22)
Quantity C
Mount to base using M6 x 1.0 hardware
at 120 mm spacing and the tee-nut bar
shipped with multi-axis stage.
Base 0.025 / 300 x 300 (0.001 / 12.0 x 12.0)
A Flatness requirement for assembly
mounting surface.
MPMA-xACxxxxxx-xxx Dimensions
A TL B TU C
Multi-axis Linear Stage Stage Length Travel Stage Length Travel Mounting Locations
Cat. No. (X-axis) (X-axis) (Y-axis) (Y-axis) (X-axis)
mm (in.) mm (in.) mm (in.) mm (in.) Qty
MPMA-AACB4B4A0-S1C 581 (22.9) 140 (5.5) 581 (22.9) 140 (5.5)
10
MPMA-AACC0C0A0-S1C 641 (25.2) 200 (7.9) 641 (25.2) 200 (7.9)
MPMA-AACC6C6A0-S1C 701 (27.6) 260 (10.2) 701 (27.6) 260 (10.2)
12
MPMA-AACD2D2A0-S1C 761 (30.0) 320 (12.6) 761 (30.0) 320 (12.6)
MPMA-BACB4B4A0-S1C 581 (22.9) 140 (5.5) 581 (22.9) 140 (5.5)
10
MPMA-BACC0C0A0-S1C 641 (25.2) 200 (7.9) 641 (25.2) 200 (7.9)
MPMA-BACC6C6A0-S1C 701 (27.6) 260 (10.2) 701 (27.6) 260 (10.2)
12
MPMA-BACD2D2A0-S1C 761 (30.0) 320 (12.6) 761 (30.0) 320 (12.6)
Actuators are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
These specifications apply to center stacked X/Y stages with 200 mm frame
ballscrew driven X-axis and 200 mm frame ballscrew driven Y-axis. Maximum
payload is 20 kg (44.0 lb). For heavier loads, contact your Rockwell Automation
sales representative.
Ø13.0 (0.5)
Access point for ballscrew
nut lubrication.
TU/2 See Detail A
44.2
(1.74) 61.5
(2.42)
B
75.3
(2.97) 130.8 239
Base (5.15) (9.4) Base 130.8
(5.15) 199.7
Carriage
(7.86)
69.7
(2.74)
TU/2
(4X) M8 X 1.25-6H 12.0 (0.47)
(4X) Ø 6.8 (0.27) 45.1 (1.78) Thru Quantity C
Mounting holes are not Mount to base using M6 x 1.0
centered on carriage. hardware at 120 mm spacing.
25.4
121.7 (1.00)
(4.79) Dimensions are in mm (in.)
101.6 Bumper Travel
(4.00)
Clearance envelope required for
Secondary connectors at orientation shown.
Detail A
Secondary is not centered 6.6 6.0 max
on base carriage. (0.26) (4X) M10 x 1.5-6H Thru (2 per end cap)
Access point for linear bearing (0.24)
lubrication. 5.22 min
(0.21)
Ground Screw 45.1
(1.78) Quantity C
(M5 x 0.8-6H) 210.9 Mount to base using M6 x 1.0 hardware
(8.30) at 120 mm spacing and the tee-nut bar
shipped with multi-axis stage.
MPMA-xAPxxxxxx-xxx Dimensions
A TL B TU C
Multi-axis Linear Stage Stage Length Travel Stage Length Travel Mounting Locations
Cat. No. (X-axis) (X-axis) (Y-axis) (Y-axis) (X-axis)
mm (in.) mm (in.) mm (in.) mm (in.) Qty
MPMA-AAPB8B8A0-S1C 521 (20.5) 180 (7.1) 521 (20.5) 180 (7.1) 8
MPMA-AAPC4C4A0-S1C 581 (22.9) 240 (9.4) 581 (22.9) 240 (9.4)
10
MPMA-AAPD0D0A0-S1C 641 (25.2) 300 (11.8) 641 (25.2) 300 (11.8)
MPMA-AAPE2E2A0-S1C 761 (30.0) 420 (16.5) 761 (30.0) 420 (16.5) 12
MPMA-AAPG6G6A0-S1C 1001 (39.4) 660 (26.0) 1001 (39.4) 660 (26.0) 16
MPMA-BAPB8B8A0-S1C 521 (20.5) 180 (7.1) 521 (20.5) 180 (7.1) 8
MPMA-BAPC4C4A0-S1C 581 (22.9) 240 (9.4) 581 (22.9) 240 (9.4)
10
MPMA-BAPD0D0A0-S1C 641 (25.2) 300 (11.8) 641 (25.2) 300 (11.8)
MPMA-BAPE2E2A0-S1C 761 (30.0) 420 (16.5) 761 (30.0) 420 (16.5) 12
MPMA-BAPG6G6A0-S1C 1001 (39.4) 660 (26.0) 1001 (39.4) 660 (26.0) 16
Actuators are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
These specifications apply to cartesian stacked X/Y stages with 250 mm frame
linear motor driven X-axis and 200 mm frame linear motor driven Y-axis.
Maximum payload is 20 kg (44.0 lb). For heavier loads, contact your Rockwell
Automation sales representative.
25.4
117.7 (1.00)
(4.63) 215.7 Bumper Travel
(8.49)
232
121.9 (9.13) Dimensions are in mm (in.) 45.1
(4.80) (1.77)
MPMA-xCBxxxxxx-xxx Dimensions
A TL B TU C
Multi-axis Linear Stage Stage Length Travel Stage Length Travel Mounting Locations
Cat. No. (X-axis) (X-axis) (Y-axis) (Y-axis) (X-axis)
mm (in.) mm (in.) mm (in.) mm (in.) Qty
MPMA-ACBD2D2A0-S1C 761 (30.0) 320 (12.6) 12
761 (30.0) 320 (12.6)
MPMA-ACBE4D2A0-S1C
881 (34.7) 440 (17.3) 14
MPMA-ACBE4E4A0-S1C
MPMA-ACBF6E4A0-S1C 1001 (39.4) 560 (22.0) 881 (34.7) 440 (17.3) 16
MPMA-ACBG8E4A0-S1C
1121 (44.1) 680 (26.8) 18
MPMA-ACBG8F6A0-S1C
MPMA-ACBI0F6A0-S1C 1241 (48.9) 800 (31.5) 1001 (39.4) 560 (22.0) 20
MPMA-ACBJ2F6A0-S1C 1361 (53.6) 920 (36.2) 22
MPMA-BCBD2D2A0-S1C 761 (30.0) 320 (12.6) 12
761 (30.0) 320 (12.6)
MPMA-BCBE4D2A0-S1C
881 (34.7) 440 (17.3) 14
MPMA-BCBE4E4A0-S1C
MPMA-BCBF6E4A0-S1C 1001 (39.4) 560 (22.0) 881 (34.7) 440 (17.3) 16
MPMA-BCBG8E4A0-S1C
1121 (44.1) 680 (26.8) 18
MPMA-BCBG8F6A0-S1C
MPMA-BCBI0F6A0-S1C 1241 (48.9) 800 (31.5) 1001 (39.4) 560 (22.0) 20
MPMA-BCBJ2F6A0-S1C 1361 (53.6) 920 (36.2) 22
Actuators are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
These specifications apply to cartesian stacked X/Y stages with 250 mm frame
ballscrew driven X-axis and 200 mm frame ballscrew driven Y-axis. Maximum
payload is 25 kg (55.1 lb). For heavier loads, contact your Rockwell Automation
sales representative.
TU/2
248.7 86.8
(9.79) 172.2 Base (3.42)
Base
(6.78) 25.4
121.7 (1.00)
(4.79) Bumper Travel
69.7
(2.74) Cable 101.6
Clearance (4.00)
MPMA-xCQxxxxxx-xxx Dimensions
A TL B TU C
Multi-axis Linear Stage Stage Length Travel Stage Length Travel Mounting Locations
Cat. No. (X-axis) (X-axis) (Y-axis) (Y-axis) (X-axis)
mm (in.) mm (in.) mm (in.) mm (in.) Qty
MPMA-ACQD0D0A0-S1C 641 (25.2) 300 (11.8) 10
641 (25.2) 300 (11.8)
MPMA-ACQE2D0A0-S1C
761 (30.0) 420 (16.5) 12
MPMA-ACQE2E2A0-S1C
761 (30.0) 420 (16.5)
MPMA-ACQG6E2A0-S1C
1001 (39.4) 660 (26.0) 16
MPMA-ACQG6G6A0-S1C
MPMA-ACQH8G6A0-S1C 1121 (44.1) 780 (30.7) 1001 (39.4) 660 (26.0) 18
MPMA-ACQJ0G6A0-S1C 1241 (48.9) 900 (35.4) 20
MPMA-BCQD0D0A0-S1C 641 (25.2) 300 (11.8) 10
641 (25.2) 300 (11.8)
MPMA-BCQE2D0A0-S1C
761 (30.0) 420 (16.5) 12
MPMA-BCQE2E2A0-S1C
761 (30.0) 420 (16.5)
MPMA-BCQG6E2A0-S1C
1001 (39.4) 660 (26.0) 16
MPMA-BCQG6G6A0-S1C
MPMA-BCQH8G6A0-S1C 1121 (44.1) 780 (30.7) 1001 (39.4) 660 (26.0) 18
MPMA-BCQJ0G6A0-S1C 1241 (48.9) 900 (35.4) 20
Actuators are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
These specifications apply to center stacked X/Z stages with 200 mm frame linear
motor driven X-axis and 150 mm frame ballscrew driven Z-axis. Maximum
payload is 20 kg (44.0 lb). For heavier loads, contact your Rockwell Automation
sales representative.
239
165 (9.4) 199.7
Base Carriage Base 130.8 (7.86)
(6.5) (5.15)
130
117.7
(5.12)
TU/2 (4.63)
MPMA-xBExxxxxx-xxx Dimensions
A TL B TU C
Multi-axis Linear Stage Stage Length Travel Stage Length Travel Mounting Locations
Cat. No. (X-axis) (X-axis) (Z-axis) (Z-axis) (X-axis)
mm (in.) mm (in.) mm (in.) mm (in.) Qty
MPMA-ABED2A0B8-S2C 530 (20.9) 180 (7.1)
761 (30.0) 320 (12.6) 12
MPMA-ABED2A0D0-S2C 650 (25.6) 300 (11.8)
MPMA-ABEE4A0B8-S2C 530 (20.9) 180 (7.1)
881 (34.7) 440 (17.3) 14
MPMA-ABEE4A0D0-S2C 650 (25.6) 300 (11.8)
MPMA-ABEG8A0B8-S2C 530 (20.9) 180 (7.1)
1121 (44.1) 680 (26.8) 18
MPMA-ABEG8A0D0-S2C 650 (25.6) 300 (11.8)
MPMA-BBED2A0B8-S2C 530 (20.9) 180 (7.1)
761 (30.0) 320 (12.6) 12
MPMA-BBED2A0D0-S2C 650 (25.6) 300 (11.8)
MPMA-BBEE4A0B8-S2C 530 (20.9) 180 (7.1)
881 (34.7) 440 (17.3) 14
MPMA-BBEE4A0D0-S2C 650 (25.6) 300 (11.8)
MPMA-BBEG8A0B8-S2C 530 (20.9) 180 (7.1)
1121 (44.1) 680 (26.8) 18
MPMA-BBEG8A0D0-S2C 650 (25.6) 300 (11.8)
Actuators are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
These specifications apply to center stacked X/Z stages with 200 mm frame
ballscrew driven X-axis and 150 mm frame ballscrew driven Z-axis. Maximum
payload is 25 kg (55.1 lb). For heavier loads, contact your Rockwell Automation
sales representative.
130 69.7
(5.12) (2.74)
TU/2
(4X) M8 X 1.25-6H 12.0 (0.47) See Detail A
30.0
163.1 (1.18)
(6.42) Dimensions are in mm (in.) Bumper Travel
MPMA-xBIxxxxxx-xxx Dimensions
A TL B TU C
Multi-axis Linear Stage Stage Length Travel Stage Length Travel Mounting Locations
Cat. No. (X-axis) (X-axis) (Z-axis) (Z-axis) (X-axis)
mm (in.) mm (in.) mm (in.) mm (in.) Qty
MPMA-ABID0A0B8-S2C 530 (20.9) 180 (7.1)
641 (25.2) 300 (11.8) 10
MPMA-ABID0A0D0-S2C 650 (25.6) 300 (11.8)
MPMA-ABIE2A0B8-S2C 530 (20.9) 180 (7.1)
761 (30.0) 420 (16.5) 12
MPMA-ABIE2A0D0-S2C 650 (25.6) 300 (11.8)
MPMA-ABIG6A0B8-S2C 530 (20.9) 180 (7.1)
1001 (39.4) 660 (26.0) 16
MPMA-ABIG6A0D0-S2C 650 (25.6) 300 (11.8)
MPMA-BBID0A0B8-S2C 530 (20.9) 180 (7.1)
641 (25.2) 300 (11.8) 10
MPMA-BBID0A0D0-S2C 650 (25.6) 300 (11.8)
MPMA-BBIE2A0B8-S2C 530 (20.9) 180 (7.1)
761 (30.0) 420 (16.5) 12
MPMA-BBIE2A0D0-S2C 650 (25.6) 300 (11.8)
MPMA-BBIG6A0B8-S2C 530 (20.9) 180 (7.1)
1001 (39.4) 660 (26.0) 16
MPMA-BBIG6A0D0-S2C 650 (25.6) 300 (11.8)
Actuators are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
These specifications apply to center stacked X/Z stages with 250 mm frame linear
motor driven X-axis and 150 mm frame ballscrew driven Z-axis. Maximum
payload is 20 kg (44.0 lb). For heavier loads, contact your Rockwell Automation
sales representative.
130
(5.12)
(4X) M6 X 1.25-6H 12.0 (0.47) TU/2 117.7
(4.63)
MPMA-xBDxxxxxx-xxx Dimensions
A TL B TU C
Multi-axis Linear Stage Stage Length Travel Stage Length Travel Mounting Locations
Cat. No. (X-axis) (X-axis) (Z-axis) (Z-axis) (X-axis)
mm (in.) mm (in.) mm (in.) mm (in.) Qty
MPMA-ABDD2A0B8-S2C 530 (20.9) 180 (7.1)
761 (30.0) 320 (12.6) 12
MPMA-ABDD2A0D0-S2C 650 (25.6) 300 (11.8)
MPMA-ABDE4A0B8-S2C 530 (20.9) 180 (7.1)
MPMA-ABDE4A0D0-S2C 881 (34.7) 440 (17.3) 650 (25.6) 300 (11.8) 14
MPMA-ABDE4A0E2-S2C 770 (30.3) 420 (16.5)
MPMA-ABDG8A0B8-S2C 530 (20.9) 180 (7.1)
MPMA-ABDG8A0D0-S2C 1121 (44.1) 680 (26.8) 650 (25.6) 300 (11.8) 18
MPMA-ABDG8A0E2-S2C 770 (30.3) 420 (16.5)
MPMA-ABDI0A0B8-S2C 530 (20.9) 180 (7.1)
MPMA-ABDI0A0D0-S2C 1241 (48.9) 800 (31.5) 650 (25.6) 300 (11.8) 20
MPMA-ABDI0A0E2-S2C 770 (30.3) 420 (16.5)
MPMA-ABDJ2A0D0-S2C 650 (25.6) 300 (11.8)
MPMA-ABDJ2A0E2-S2C 1361 (53.6) 920 (36.2) 770 (30.3) 420 (16.5) 22
MPMA-ABDJ2A0F4-S2C 890 (35.0) 540 (21.3)
MPMA-BBDD2A0B8-S2C 530 (20.9) 180 (7.1)
761 (30.0) 320 (12.6) 12
MPMA-BBDD2A0D0-S2C 650 (25.6) 300 (11.8)
MPMA-BBDE4A0B8-S2C 530 (20.9) 180 (7.1)
MPMA-BBDE4A0D0-S2C 881 (34.7) 440 (17.3) 650 (25.6) 300 (11.8) 14
MPMA-BBDE4A0E2-S2C 770 (30.3) 420 (16.5)
MPMA-BBDG8A0B8-S2C 530 (20.9) 180 (7.1)
MPMA-BBDG8A0D0-S2C 1121 (44.1) 680 (26.8) 650 (25.6) 300 (11.8) 18
MPMA-BBDG8A0E2-S2C 770 (30.3) 420 (16.5)
MPMA-BBDI0A0B8-S2C 530 (20.9) 180 (7.1)
MPMA-BBDI0A0D0-S2C 1241 (48.9) 800 (31.5) 650 (25.6) 300 (11.8) 20
MPMA-BBDI0A0E2-S2C 770 (30.3) 420 (16.5)
MPMA-BBDJ2A0D0-S2C 650 (25.6) 300 (11.8)
MPMA-BBDJ2A0E2-S2C 1361 (53.6) 920 (36.2) 770 (30.3) 420 (16.5) 22
MPMA-BBDJ2A0F4-S2C 890 (35.0) 540 (21.3)
Actuators are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions
without tolerances are for reference.
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your actuator. For questions regarding product
availability, contact your Allen-Bradley distributor.
MP MA - x x x x x x x x x - x x x
Cable
C = Cable track module with IP67 SpeedTec DIN connectors (applies to all Bulletin MPMA stages)
Limits and Brake Options
X-axis Y-axis Z-axis
1 = No brake, no limits 1 = No brake, no limits 1 = None
2 = No brake, no limits 2 = None 2 = 24V brake, no limits (ballscrew only)
Protection Options (same as Bulletin MPAS options)
S = Covered with strip seals (applies to all Bulletin MPMA stages)
Z-axis 10s of mm
0 = 0 mm 2 = 20 mm 4 = 40 mm 6 = 60 mm 8 = 80 mm
1 = 10 mm 3 = 30 mm 5 = 50 mm 7 = 70 mm 9 = 90 mm
Z-axis 100s of mm
A = 0 mm C = 200 mm E = 400 mm
B = 100 mm D = 300 mm F = 500 mm
Y-axis 10s of mm
0 = 0 mm 2 = 20 mm 4 = 40 mm 6 = 60 mm 8 = 80 mm
1 = 10 mm 3 = 30 mm 5 = 50 mm 7 = 70 mm 9 = 90 mm
Y-axis 100s of mm
A = 0 mm C = 200 mm E = 400 mm G = 600 mm
B = 100 mm D = 300 mm F = 500 mm
X-axis 10s of mm
0 = 0 mm 2 = 20 mm 4 = 40 mm 6 = 60 mm 8 = 80 mm
1 = 10 mm 3 = 30 mm 5 = 50 mm 7 = 70 mm 9 = 90 mm
X-axis 100s of mm
A = 0 mm C = 200 mm E = 400 mm G = 600 mm I = 800 mm
B = 100 mm D = 300 mm F = 500 mm H = 700 mm J = 900 mm
Bulletin MPAS Linear Stage
X-axis (base) Y-axis (secondary) Z-axis (secondary)
B = MPAS-x9xxxK/L-ALMS2x B = MPAS-x8xxxF/E-ALMS2x B = None
C = MPAS-x9xxxK/L-ALMS2x C = MPAS-x9xxxK/L-ALMS2x C = None
D = MPAS-x9xxxK/L-ALMS2x D = None D = MPAS-x6xxx2-V20S4x
E = MPAS-x8xxxF/E-ALMS2x E = None E = MPAS-x6xxx2-V20S4x
I = MPAS-x8xxx2-V20S2x I = None I = MPAS-x6xxx2-V20S4x
P = MPAS-x8xxx2-V20S2x P = MPAS-x8xxx2-V20S2x P = None
Q = MPAS-x9xxx2-V20S2x Q = MPAS-x8xxx2-V20S2x Q = None
Configuration
A = Center stacked XY
B = Center stacked XZ
C = Cartesian stacked XY (left-side cantilever)
Voltage Class
A = 200V
B = 400V
Actuator Type
MA = Actuator, multi-axis linear stage
Actuator Series
MP = MP-Series
MP-Series (Bulletin MPAR) electric cylinders are equipped with threaded DIN and SpeedTec DIN connectors.
SpeedTec DIN (M7) Cable Plug
O-ring
SpeedTec-ready
DIN Connectors
• 2090-CFBM7DF-CEAAxx (standard) flying-lead, feedback cables
• MPAR-A/B3xxxx electric cylinders
• 2090-CFBM7DD-CEAAxx (standard) drive-end connector, feedback cables
• Receives M4 and M7 cable plugs
(remove the O-ring for M7) • 2090-CFBM7DF-CEAFxx (continuous-flex) flying-lead, feedback cables
• Attach M7 cable plug with one-quarter turn • 2090-CFBM7DD-CEAFxx (continuous-flex) drive-end connector, feedback cables
• Attach M4 cable plug with 5…6 turns • 2090-CPWM7DF-16AAxx (standard) power-only cables
• 2090-CPBM7DF-16AAxx (standard) power/brake cables
• 2090-CPWM7DF-16AFxx (continuous-flex) power-only cables
• 2090-CPBM7DF-16AFxx (continuous-flex) power/brake cables
TL-Series (Bulletin TLAR) electric cylinders are equipped with circular plastic connectors.
Threaded Plastic (M6) Cable Plugs
1
4
7
3 6
5 9
8
11 13
10
12
11
17
4
14
16 19
18 20
9 21
15
1
22
2
3
4
Mounting Attachments
Cat. No.
Cat. No.
Accessory Item Description Corrosion Dimensions
Standard Resistant
Parallel applications. Includes
1 Foot mount MPAR-NP1743xx MPAR-NP1769xx page 162
two foot mounts and mounting bolts.
2 Front flange mounting MPAR-NA17437x MPAR-NA16184x page 163
In-line or parallel applications. Includes mounting bolts.
3 Trunnion flange MPAR-NA17441x MPAR-NA16185x page 163
4 Trunnion support In-line or parallel applications. Use with item 3. MPAR-NA329xx MPAR-NA16187x page 164
Swivel flange Parallel applications. Use with items 6 or 7. Includes swivel
5 MPAR-NP17438x N/A page 165
(pin, narrow) flange, pivot pin, mounting screws, and retaining clip.
Clevis foot Parallel applications. Use with item 5. Includes 1 flange with
6 MPAR-NP3174x N/A page 166
(spherical bearing) spherical bearing.
Clevis foot Parallel applications. Use with item 5. Includes 1 bracket with
7 MPAR-NP317xx N/A page 165
(weld-on) spherical bearing.
Swivel flange Parallel applications. Use with item. Includes 1 flange with
8 MPAR-NP174xxx N/A page 167
(spherical bearing) spherical bearing and mounting bolts.
11 Swivel flange Parallel applications. Use with items 10, 12, or 13. Includes swivel MPAR-NP17439x MPAR-NP17694x page 168
(pin, wide) flange, pivot pin, mounting screws, and retaining clips.
12 Clevis foot Parallel applications. Use with item 11. MPAR-NP3389x MPAR-NP16184x page 169
13 Clevis foot Parallel applications. Use with item 11. Includes flange with MPAR-NP556x N/A page 170
(spherical bearing) spherical bearing and cylindrical spacers.
In-line or parallel applications. For mounting anywhere along the
cylinder barrel profile. Cannot be mounted in the vicinity of the
14 Trunnion mounting kit MPAR-NA16352x N/A page 171
motor with parallel motor attachment. Kit includes trunnion mount
and supports.
In-line applications. For mounting anywhere along the cylinder
15 Foot mounting kit barrel profile. Kit includes bracket, body clamps, foot mount MPAR-NA17499x N/A page 172
attachment, and mounting bolts.
16 Clevis foot In-line or parallel applications. Use with item 17. Includes clevis MPAR-NA317xx N/A page 173
(right angle) foot, pivot pin, and retaining clip.
Rod-end Attachments
Cat. No.
Cat. No.
Accessory Item Description Corrosion Dimensions
Standard Resistant
In-line or parallel applications. Use with items 16, 18, or 9.
17 Rod eye MPAR-NE926x MPAR-NE19558x page 174
Includes rod eye and hex nut.
In-line or parallel applications. Use with item 17. For spherical
18 Rod clevis connection of cylinders with rod eye. Includes rod clevis, pivot pin, MPAR-NExxxxx N/A page 175
(threaded rod) and retaining clip.
In-line or parallel applications. Use with item 17. Permits a
19 Rod clevis swivelling movement of the cylinder in one plane. Includes rod MPAR-NE614x MPAR-NE135xx page 175
(threaded hole) clevis, pivot pin, and retaining clip.
In-line or parallel applications. Links the piston rod-end of the
cylinder to the machine parts to be moved. Used to compensate
20 Coupling piece MPAR-NE3612x N/A page 177
for radial misalignment. Includes flange plate and threaded
coupling.
In-line or parallel applications. Links the piston rod-end of the
cylinder to the machine parts to be moved. Used to compensate
21 Rod coupler MPAR-NE614x N/A page 178
for radial and angular misalignment. Includes rod coupler and hex
nut.
In-line or parallel applications. Used to protect piston rod against
22 Rod guide MPAR-NExxxxx N/A page 181
radial or torsional side loads.
Electric cylinders must have the weight of the load supported and guided separately so that only axial force (no radial load)
is required of the piston rod throughout the complete extend and retract motion. If some residual radial and/or torsional
loading remains unavoidable, it may be necessary to add a rod guide. Refer to Motion Analyzer software, version 4.7 or
later, for assistance when making these calculations and to determine when a rod guide is recommended.
Maximum Permissible Lateral Forces Fymax and Fzmax on the Piston Rod
[Fx] Fx max
[Mx] Mx max
100 100
Fy, Fz, (N)
50 50
10 10
5 5
1 1
0 100 200 300 400 500 600 700 800 0 100 200 300 400 500 600 700 800
l (mm) l (mm)
These specifications are for determining the amount of shaft deflection to expect from a given load.
4
3.5 2.1 mm (0.083 in.) deflection at
3 stroke limit of 188 mm (7.40 in.)
for 45 N (10.1 lb) load.
2.5
f (mm)
2
1.5 Lateral Force F = 0 N
Lateral Force F = 10 N (2.25 lb)
1 Lateral Force F = 20 N (4.50 lb)
0.5 Lateral Force F = 45 N (10.10 lb)
0
0 50 100 150 200 250 300 350 400
l (mm)
7
6
5
1.9 mm (0.075 in.) deflection at
4 stroke limit of 185 mm (7.28 in.)
f (mm)
7
6
3.1 mm (0.122 in.) deflection at
5 stroke limit of 389 mm (15.31 in.)
for 95 N (21.36 lb) load.
4
f (mm)
Lateral Force F = 0 N
3 Lateral Force F = 20 N (4.50 lb)
Lateral Force F = 30 N (6.74 lb)
2
Lateral Force F = 40 N (8.99 lb)
1 Lateral Force F = 95 N (21.36 lb)
0
0 100 200 300 400 500 600 700 800
l (mm)
Electric cylinder life specifications, running performance (L), are based on a combination of tested and calculated data. If
the parameters of your application are different, your results could be different. The achievable running performance (L) is
a function of mean feed force (F), according to DIN 69051-4 as shown below and illustrated on page 141. Refer to Motion
Analyzer software, version 4.7 or later, for assistance when making these calculations and determining the running
performance for your application.
The peak feed force value must not exceed the maximum feed force within a movement cycle. In the
Fx Fx max
case of vertical operation, the peak value is generally achieved during the acceleration phase of the
and
upwards stroke. If the maximum feed force is exceeded, you can increase wear and shorten the service life
Vx Vx max
of the ballscrew. The maximum speed must likewise not be exceeded.
During operation, the continuous feed force may be briefly exceeded up to the maximum feed force.
Fxm Fx cont
The continuous feed force must, however, be adhered to when averaged over a movement cycle.
vx (mm/s)
q q1 q2 q3
vxm = |vx| x + |vx1| x + |vx2| x + |vx3| x +
100 100 100 100 vx3 vxm
vx1
q1 q2 q3
q (100%)
Fxm
Fx2
3
Fxm = |Fx1|3 x |vx1| x q1 + |Fx2|3 x |vx2| x q2 + |Fx3|3 x |vx3| x q3 +
|vxm| 100 |vxm| 100 |vxm| 100
q1 q2 q3
Fx = Feed Force Vx = Feed Speed q (100%)
Fxm = Mean Feed Force Vxm = Mean Feed Speed
Fxmax = Maximum Feed Force Vxmax = Maximum Feed Speed
Fxcont = Continuous Feed Force
q = % of Time
The achievable running performance (L) is a function of mean feed force (F), according to DIN 69051-4 as illustrated in
the figures below.
500
400
300
F (N)
200
100
MPAR-A/B1xxxB or TLAR-A1xxxB
MPAR-A/B1xxxE or TLAR-A1xxxE
0
0 2500 5000 7500 10000
L (km)
1000
800
600
F (N)
400
200
MPAR-A/B2xxxC or TLAR-A2xxxC
MPAR-A/B2xxxF or TLAR-A2xxxF
0
0 2500 5000 7500 10000
L (km)
3000
2500
2000
1500
F (N)
1000
500 MPAR-A/B3xxxE or TLAR-A3xxxE
MPAR-A/B3xxxH or TLAR-A3xxxH
0
0 2500 5000 7500 10000
L (km)
Electric Cylinder Weight, (1) Electric Cylinder Weight, Electric Cylinder Weight,
approx. approx. approx.
Cat. No. Cat. No. Cat. No.
kg (lb) kg (lb) kg (lb)
MPAR-x1100B-V2A 2.6 (5.73) MPAR-x2100C-V2A 3.7 (8.16) (1) MPAR-x3100E-M2A 9.5 (20.94) (2)
MPAR-x1100B-V2B/D/E 3.5 (7.72) MPAR-x2100C-V2B/D/E 4.4 (9.70) (1) MPAR-x3100E-M2B/D/E 13.6 (29.98) (2)
MPAR-x1200B-V2A 2.9 (6.39) MPAR-x2200C-V2A 4.1 (9.04) (1) MPAR-x3200E-M2A 10.3 (22.71) (2)
MPAR-x1200B-V2B/D/E 3.8 (8.377) MPAR-x2200C-V2B/D/E 4.9 (10.80) (1) MPAR-x3200E-M2B/D/E 14.4 (31.75) (2)
MPAR-x1300B-V2A 3.2 (7.05) MPAR-x2300C-V2A 4.6 (10.14) (1) MPAR-x3300E-M2A 11.1 (24.47) (2)
MPAR-x1300B-V2B/D/E 4.1 (9.04) MPAR-x2300C-V2B/D/E 5.3 (11.68) (1) MPAR-x3300E-M2B/D/E 15.2 (33.51) (2)
MPAR-x1400B-V2A 3.5 (7.72) MPAR-x2400C-V2A 5.0 (11.02) (1) MPAR-x3400E-M2A 11.9 (26.23) (2)
MPAR-x1400B-V2B/D/E 4.5 (9.92) MPAR-x2400C-V2B/D/E 5.8 (12.79) (1) MPAR-x3400E-M2B/D/E 16.1 (35.49) (2)
MPAR-x1100E-V2A 3.0 (6.61) MPAR-x2600C-V2A 6.0 (11.02) (1) MPAR-x3600E-M2A 13.5 (29.76) (2)
MPAR-x1100E-V2B/D/E 3.8 (8.377) MPAR-x2600C-V2B/D/E 6.7 (14.77) (1) MPAR-x3600E-M2B/D/E 17.7 (39.02) (2)
MPAR-x1200E-V2A 3.3 (7.27) MPAR-x2100F-V2A 4.2 (9.26) (3) MPAR-x3800E-M2A 15.2 (33.51) (2)
MPAR-x1200E-V2B/D/E 4.1 (9.04) MPAR-x2100F-V2B/D/E 6.5 (14.33) (3) MPAR-x3800E-M2B/D/E 19.3 (42.55) (2)
MPAR-x1300E-V2A 3.6 (7.94) MPAR-x2200F-V2A 4.7 (10.36) (3) MPAR-x3100H-M2A 9.3 (20.50) (4)
MPAR-x1300E-V2B/D/E 4.5 (9.92) MPAR-x2200F-V2B/D/E 7.0 (15.43) (3) MPAR-x3100H-M2B/D/E 13.2 (29.10) (4)
MPAR-x1400E-V2A 4.0 (8.82) MPAR-x2300F-V2A 5.2 (11.46) (3) MPAR-x3200H-M2A 10.1 (22.27) (4)
MPAR-x1400E-V2B/D/E 4.8 (10.58) MPAR-x2300F-V2B/D/E 7.5 (16.53) (3) MPAR-x3200H-M2B/D/E 14.0 (30.86) (4)
(1) If ordering MPAR-x1xxxx-V4x or MPAR-x2xxxC-V4x electric cylinder with brake, add 0.2 kg (0.4 lb).
(2) If ordering MPAR-x3xxxE-M4x electric cylinder with brake, add 1.0 kg (2.2 lb).
(3) If ordering MPAR-x2xxxF-V4x electric cylinder with brake, add 0.4 kg (0.9 lb).
(4) If ordering MPAR-x3xxxH-M4x electric cylinder with brake, add 1.7 kg (3.7 lb).
Electric Cylinder Weight, approx. Electric Cylinder Weight, approx. (1) Electric Cylinder Weight, approx. (2)
Cat. No. kg (lb) Cat. No. kg (lb) Cat. No. kg (lb)
TLAR-A1100B-B2A 1.7 (3.75) (3) TLAR-A2100C-B2A 3.1 (6.83) TLAR-A3100E-B2A 8.7 (19.18)
(3)
TLAR-A1200B-B2A 2.0 (4.41) TLAR-A2200C-B2A 3.6 (7.94) TLAR-A3200E-B2A 9.5 (20.94)
TLAR-A1300B-B2A 2.4 (5.29) (3) TLAR-A2300C-B2A 4.0 (8.82) TLAR-A3300E-B2A 10.3 (22.71)
TLAR-A1400B-B2A 2.7 (5.95) (3) TLAR-A2400C-B2A 4.5 (9.92) TLAR-A3400E-B2A 11.1 (24.47)
(4)
TLAR-A1100E-B2A 2.4 (5.29) TLAR-A2600C-B2A 5.4 (11.90) TLAR-A3600E-B2A 12.7 (28.0)
(4)
TLAR-A1200E-B2A 2.8 (6.17) TLAR-A2100F-B2A 3.7 (8.16) TLAR-A3800E-B2A 14.3 (31.52)
TLAR-A1300E-B2A 3.1 (6.83) (4) TLAR-A2200F-B2A 4.1 (9.04) TLAR-A3100H-B2A 8.7 (19.18)
(4)
TLAR-A1400E-B2A 3.4 (7.49) TLAR-A2300F-B2A 4.6 (10.14) TLAR-A3200H-B2A 9.5 (20.94)
TLAR-A2400F-B2A 5.1 (11.24) TLAR-A3300H-B2A 10.3 (22.71)
TLAR-A2600F-B2A 6.0 (13.23) TLAR-A3400H-B2A 11.1 (24.47)
TLAR-A3600H-B2A 12.7 (28.0)
TLAR-A3800H-B2A 14.3 (31.52)
(1) If ordering TLAR-A2xxxx-B4A electric cylinder with brake, add 0.4 kg (0.9 lb).
(2) If ordering TLAR-A3xxxx-B4A electric cylinder with brake, add 0.6 kg (1.3 lb).
(3) If ordering TLAR-A1xxxB-B4A electric cylinder with brake, add 0.2 kg (0.4 lb).
(4) If ordering TLAR-A1xxxE-B4A electric cylinder with brake, add 0.5 kg (1.1 lb).
Actuator Cylinder (1) Weight, approx. Actuator Cylinder (1) Weight, approx. Actuator Cylinder (1) Weight, approx.
Cat. No. kg (lb) Cat. No. kg (lb) Cat. No. kg (lb)
MPAR-X1100B 1.1 (2.43) MPAR-X2100C 1.7 (3.75) MPAR-X3100E 3.8 (8.38)
MPAR-X1200B 1.4 (3.09) MPAR-X2200C 2.2 (4.85) MPAR-X3200E 4.6 (10.14)
MPAR-X1300B 1.7 (3.75) MPAR-X2300C 2.6 (5.73) MPAR-X3300E 5.4 (11.90)
MPAR-X1400B 2.1 (4.63) MPAR-X2400C 3.1 (6.83) MPAR-X3400E 6.3 (13.89)
MPAR-X1100E 1.1 (2.43) MPAR-X2600C 4.0 (8.82) MPAR-X3600E 7.9 (17.42)
MPAR-X1200E 1.4 (3.09) MPAR-X2100F 1.8 (3.97) MPAR-X3800E 9.5 (20.94)
MPAR-X1300E 1.8 (3.97) MPAR-X2200F 2.3 (5.07) MPAR-X3100H 3.8 (8.38)
MPAR-X1400E 2.1 (4.63) MPAR-X2300F 2.8 (6.17) MPAR-X3200H 4.6 (10.14)
MPAR-X2400F 3.2 (7.05) MPAR-X3300H 5.4 (11.90)
MPAR-X2600F 4.2 (9.26) MPAR-X3400H 6.3 (13.89)
MPAR-X3600H 7.9 (17.42)
MPAR-X3800H 9.5 (20.94)
(1) Replacement actuator cylinders apply to MP-Series and TL-Series electric cylinders. For example, if ordering a replacement cylinder for electric cylinder catalog numbers
MPAR-A2100C-V2A or TLAR-A2100C-B2A, the replacement actuator cylinder catalog number is MPAR-X2100C.
Frame
Frame
Weight, approx. Weight, approx.
Accessory Item Cat. No. Accessory Item Cat. No.
g (oz) g (oz)
Frame
Frame
Weight, approx. Weight, approx.
Accessory Item Cat. No. Accessory Item Cat. No.
g (oz) g (oz)
MP-Series and TL-Series Electric Cylinders Rod Guide (item 22) Accessories
Frame
Notes:
E TG
HD
Linear Motion
See Detail A
6.0 (0.24) M6 (x4) Bulletin MPAR-x1xxxx-VxA (in-line configuration) AD
(x4) LE
Feedback WH LB
Connector Power/Brake L1
Connector VD
AM
MP-Series Electric Cylinder Dimensions
G GI
Dimensions ZJ and L7
L2+ + = Plus Stroke Length are with piston rod
ZJ+ fully retracted.
Flat for Wrench L7
Ø16.0 16.0
MPAR-x1xxxx-VxB (0.63) h9 M10x1.25 (0.63)
LB LC PW
Ø30.0
AD (1.18) d11
Bulletin MPAR-x1xxxx-VxB/D/E
L71 TG TG
GC
MP-Series Electric Cylinder Dimensions (in-line configuration, frame 32)
MPAR-x1400B-V2A 745.7 (29.36) 55.0 66.5 94.0 22.0 24.0 26.0 18.0 122.0 148.0 10.0 26.0 45.5 32.5
MPAR-x1100E-V2A 470.7 (18.53) (2.17) (2.62) (3.70) (0.87) (0.94) (1.02) (0.71) (4.80) (5.83) (0.39) (1.02) (1.79) (1.28)
(1) If ordering MPAR-A/B1xxxx-V4A actuator with brake, add 36.1 mm (1.42 in.) to dimensions L7 and LB.
(2) If ordering MPAR-A/B1xxxx-V4A actuator with brake, add 33.4 mm (1.31 in.) to dimension LE.
(3) The tolerance for this dimension is ±1.0 mm (0.039 in.).
151
Chapter 2
152
MP-Series Electric Cylinders Dimensions (frame 40)
Chapter 2
E TG
HD
Linear Motion
See Detail A AD
6.0 (0.24) M6 (x4) Bulletin MPAR-x2xxxx-VxA (in-line configuration)
(x4) LE
Feedback WH LB
Connector Power/Brake L1
Connector VD
AM
G GI
Dimensions ZJ and L7
L2+ are with piston rod
+ = Plus Stroke Length
ZJ+ fully retracted.
Flat for Wrench L7
Ø20.0 16.0
MPAR-x2xxxx-VxB (0.79) h9 (0.63)
M12x1.25
LB LC PW
Ø35.0
AD (1.38) d11
Bulletin MPAR-x2xxxx-VxB/D/E
L71 TG TG
GC
MP-Series Electric Cylinder Dimensions (in-line configuration, frame 40)
(1) If ordering MPAR-A/B2xxxC-V4A actuator with brake, add 36.1 mm (1.42 in.) to dimensions L7 and LB.
If ordering MPAR-A/B2xxxF-V4A actuator with brake, add 39.0 mm (1.54 in.) to dimensions L7 and LB.
(2) If ordering MPAR-A/B2xxxC-V4A actuator with brake, add 33.4 mm (1.31 in.) to dimension LE.
If ordering MPAR-A/B2xxxF-V4A actuator with brake, add 24.7 mm (0.97 in.) to dimension LE.
(3) The tolerance for this dimension is ±1.0 mm (0.039 in.).
153
Chapter 2
154
MP-Series Electric Cylinders Dimensions (frame 63)
Chapter 2
E
Dimensions are in mm (in.) P
TG
Linear Motion
E TG
HD
See Detail A Bulletin MPAR-x3xxxx-MxA (in-line configuration) AD
8.0 (0.31) M8 (x4)
(x4) LE
WH LB
Feedback
Connector Power/Brake
Connector VD
AM
G GI
Dimensions ZJ and L7
L2+ are with piston rod
+ = Plus Stroke Length fully retracted.
ZJ+
Flat for Wrench L7
Ø45.0
AD
(1.77) d11
Bulletin MPAR-x3xxxx-MxB/D/E
L71 TG TG
GC
MP-Series Electric Cylinder Dimensions (in-line configuration, frame 63)
(1) If ordering MPAR-A/B3xxxE-M4A actuator with brake, add 34.5 mm (1.36 in.) to dimensions L7, LB, and LE.
If ordering MPAR-A/B3xxxH-M4A actuator with brake, add 48.5 mm (1.91 in.) to dimensions L7, LB, and LE.
(2) The tolerance for this dimension is ±1.0 mm (0.039 in.).
155
Chapter 2
156
TL-Series Electric Cylinders Dimensions (frame 32 and 40)
Chapter 2
TG P
Dimensions are in mm (in.)
AD
E M6
TG
Linear Motion
(x4) HD
See Detail A
6.0 (0.24)
(x4) 1000 (39.4)
±50 (1.97)
Power/Brake Feedback
Connector Connector
TL-Series Electric Cylinder Dimensions
WH
L1
VD
AM
G GI LB
L2+
+ = Plus Stroke Length
ZJ+
Flat for Wrench
L7
Dimensions ZJ and L7 are with piston rod fully retracted.
Ø30.0 Ø35.0
(1.18) d11 (1.38) d11
TLAR-A1400B-B2A 691.5 (27.22) 22.0 24.0 26.0 18.0 122.0 148.0 10.0 26.0 45.5 32.5
TLAR-A1100E-B2A 405.5 (15.96) (0.87) (0.94) (1.02) (0.71) (4.80) (5.83) (0.39) (1.02) (1.79) (1.28)
(1) If ordering TLAR-A1xxxB-B4A actuator with brake, add 35.4 mm (1.39 in.) to dimensions L7 and LB.
If ordering TLAR-A2xxxE-B4A actuator with brake, add 34.6 mm (1.36 in.) to dimensions L7 and LB.
(2) The tolerance for this dimension is ±1.0 mm (0.039 in.).
(1) If ordering TLAR-A2xxxx-B4A actuator with brake, add 34.6 mm (1.36 in.) to dimensions L7 and LB.
(2) The tolerance for this dimension is ±1.0 mm (0.039 in.).
Linear Motion
Actuators are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions without tolerances are for reference.
157
Chapter 2
158
TL-Series Electric Cylinders Dimensions (frame 63)
Chapter 2
TG P
Dimensions are in mm (in.)
AD
M8
E TG (x4)
Linear Motion
HD
See Detail A
8.0 (0.31)
(x4) 1000 (39.4)
±50 (1.97)
Power/Brake Feedback
Connector Connector
WH
L1
VD
AM
G GI LB
L2+
+ = Plus Stroke Length
ZJ+
Flat for Wrench
L7
Dimensions ZJ and L7 are with piston rod fully retracted.
Ø45.0
(1.77) d11
20.0 17 Detail A
(0.79) Frame 63
TL-Series Electric Cylinder Dimensions (frame 63)
(1) If ordering TLAR-A3xxxx-B4A actuator with brake, add 23.0 mm (0.91 in.) to dimensions L7 and LB.
(2) The tolerance for this dimension is ±1.0 mm (0.039 in.).
Actuators are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions without tolerances are for reference.
159
Chapter 2
160
Chapter 2
E
Dimensions are in mm (in.) D4
TG
B2
Linear Motion
E TG B1
See Detail A
K3 RT B1
4x 4x B2
WH
L1
VD L4
AM
G GI D2 D3
VA
L2+
Flat for Wrench + = Plus Stroke Length
Electric Cylinder Dimensions (replacement components)
ZJ+ L3
Dimension ZJ is with piston rod fully retracted.
Frame
Cat. No. (1) h6 f7
MPAR-X1xxxB 22.0 24.0 26.0 18.0 122.0 15.9 8.0 148.0 7.0 10.0 26.0 6.0 32.0 19.0 32.0 45.5 32.5 6.0
32 (0.87) (0.94) (1.02) (0.71) (4.80) (0.63) (0.31) (5.83) (0.28) (0.39) (1.02) (0.24) (1.26) M3 (0.75) (1.26) (1.79) M6 (1.28) (0.24)
MPAR-X1xxxE
MPAR-X2xxxC 24.0 28.5 30.0 21.5 146.5 18.4 14.0 176.5 7.0 10.5 30.0 8.0 40.0 20.0 42.0 54.0 38.0 6.0
40 M4 M6
MPAR-X2xxxF (0.94) (1.12) (1.18) (0.85) (5.77) (0.72) (0.55) (6.95) (0.28) (0.41) (1.18) (0.31) (1.57) (0.79) (1.65) (2.13) (1.50) (0.24)
MPAR-X3xxxE 32.0 34.0 36.0 28.5 177.0 23.5 17.0 214.0 9.0 15.0 37.0 12.0 60.0 31.0 62.0 75.5 56.5 8.0
63 (1.26) (1.34) (1.42) (1.12) (6.97) (0.93) (0.67) (8.43) (0.35) (0.59) (1.46) (0.47) (2.36) M5 (1.22) (2.44) (2.97) M8 (2.22) (0.31)
MPAR-X3xxxH
(1) These catalog numbers apply to both MP-Series and TL-Series electric cylinders. For example, the replacement cylinder for MPAR-A1100B-V2A and TLAR-A1100B-B2A is catalog number MPAR-X1100B.
(2) The tolerance for this dimension is ±1.0 mm (0.039 in.).
These replacement cylinders are available in the event of bent rods or other damage to the cylinder. For replacement motors, couplings, and belts, refer to
MP-Series and TL-Series Electric Cylinder Replacement Parts Installation Instructions, publication MPAR-IN002.
Actuators are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions without tolerances are for reference.
161
Chapter 2
Chapter 2 Linear Motion
These accessories apply to MP-Series and TL-Series electric cylinders. Components are designed to metric dimensions.
Inch dimensions are approximate conversions from millimeters. Dimensions without tolerances are for reference.
XL+
Ø FB Dimensions are in mm (in.)
Attachment includes:
• 2 Foot mount attachments
• 4 Mounting bolts
MPAR-NP174370 MPAR-NP176938 40 14.0 (3) 10.0 46.0 (3) 9.0 28.0 36.0 54.0 260.5 (4) 258.5 (4)
(0.55) (0.39) (1.81) (0.34) (1.10) (1.42) (2.12) (10.25) (10.18)
MPAR-NP174372 MPAR-NP176940 63 13.0 (3) 10.0 58.0 (3) 12.5 32.0 50.0 75.0 328.3 323.3
(0.51) (0.39) (2.28) (0.49) (1.26) (1.97) (2.95) (12.92) (12.73)
E R
FB
Cat. No. (2) E MF R TF UF W
Frame
Cat. No. (1) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
Corrosion Resistant H13
45.0 7.0 10.0 32.0 64.0 80.0 16.0
MPAR-NA174376 MPAR-NA161846 32 (1.77) (0.28) (0.39) (1.26) (2.52) (3.15) (0.63)
54.0 9.0 10.0 36.0 72.0 90.0 20.0
MPAR-NA174377 MPAR-NA161847 40 (2.13) (0.35) (0.39) (1.42) (2.83) (3.54) (0.79)
75.0 9.0 12.0 50.0 100 120 25.0
MPAR-NA174379 MPAR-NA161849 63 (2.95) (0.35) (0.47) (1.97) (3.94) (4.72) (0.98)
(1) Material is galvanized steel and subject to moderate corrosion stress. Contains no copper, PTFE, or silicone.
(2) Material is high-alloy steel for environments requiring higher corrosion resistance. Contains no copper, PTFE, or silicone.
US
TD
Attachment includes:
(3) • 1 Trunnion mounting
C2 TK
• 4 Mounting bolts
C3 (3)
Bulletin TLAR In-line
Bulletin MPAR In-line
Bulletin MPAR Parallel
TD
Cat. No. (2) C2 C3 TK TL TM US XH
Frame
Cat. No. (1) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
Corrosion Resistant e9
71.0 86.0 12.0 16.0 12.0 50.0 45.0 18.0
MPAR-NA174411 MPAR-NA161852 32 (2.80) (3.39) (0.47) (0.63) (0.47) (1.97) (1.77) (0.71)
87.0 105 16.0 20.0 16.0 63.0 54.0 20.0
MPAR-NA174412 MPAR-NA161853 40 (3.43) (4.13) (0.63) (0.79) (0.63) (2.48) (2.13) (0.79)
116 136 20.0 24.0 20.0 90.0 75.0 25.0
MPAR-NA174414 MPAR-NA161855 63 (4.57) (5.35) (0.79) (0.94) (0.79) (3.54) (2.95) (0.98)
(1) Material is special steel casting and subject to moderate corrosion stress. Contains no copper, PTFE, or silicone.
(2) Material is electrolytically-polished special steel casting for environments requiring higher corrosion resistance. Contains no copper, PTFE, or silicone.
(3) These dimensions are drawn to the trunnion support attachment as shown on page 164 (not included with the trunnion flange attachment).
FS
H1 NH
TH
UL
KE
DA
HB
CR DA HB
FK (2) FN FS H1 KE NH TH (3) UL
Frame
Cat. No. (1) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
D11 H13 H13
12.0 11.0 15.0 30.0 10.5 15.0 6.6 6.8 18.0 32.0 46.0
MPAR-NA32959 32 (0.47) (0.43) (0.59) (1.18) (0.41) (0.59) (0.26) (0.27) (0.71) (1.26) (1.81)
16.0 15.0 18.0 36.0 12.0 18.0 9.0 9.0 21.0 36.0 55.0
MPAR-NA32960 40 (0.63) (0.59) (0.71) (1.42) (0.47) (0.71) (0.35) (0.35) (0.83) (1.42) (2.17)
20.0 18.0 20.0 40.0 13.0 20.0 11.0 11.0 23.0 42.0 65.0
MPAR-NA32961 63 (0.79) (0.71) (0.79) (1.57) (0.51) (0.79) (0.43) (0.43) (0.91) (1.65) (2.56)
(1) Material is anodized aluminum and subject to moderate corrosion stress. Plain bearing: Polymer. Contains no copper, PTFE, or silicone.
(2) Tolerance for this dimension is ±0.1 mm (±0.0039 in.).
(3) Tolerance for this dimension is ±0.2 mm (±0.0079 in.).
TH
UL
CR HB
FK (2) FN FS H1 NH TH (3) UL
Frame
Cat. No. (1) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
D11 H13
12.0 15.0 30.0 10.5 15.0 6.6 18.0 32.0 46.0
MPAR-NA161874 32 (0.47) (0.59) (1.18) (0.41) (0.59) (0.26) (0.71) (1.26) (1.81)
16.0 18.0 36.0 12.0 18.0 9.0 21.0 36.0 55.0
MPAR-NA161875 40 (0.63) (0.71) (1.42) (0.47) (0.71) (0.35) (0.83) (1.42) (2.17)
20.0 20.0 40.0 13.0 20.0 11.0 23.0 42.0 65.0
MPAR-NA161876 63 (0.79) (0.79) (1.57) (0.51) (0.79) (0.43) (0.91) (1.65) (2.56)
(1) Material is high-alloy steel for environments requiring higher corrosion resistance. Contains no copper, PTFE, or silicone.
(2) Tolerance for this dimension is ±0.1 mm (±0.0039 in.).
(3) Tolerance for this dimension is ±0.2 mm (±0.0079 in.).
RF ØD
Attachment includes
• 1 Swivel flange
+ = Plus Stroke Length C A • 1 Pivot pin
H B • 4 Mounting screws
SL+ • 1 Retaining clip
A B
D C H (2) RF SL+
Frame
Cat. No. (1) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
H14 h14
MPAR-NP174383 32 10.0 (0.39) 14.0 (0.55) 34.0 (1.34) 13.0 (0.51) 22.0 (0.86) 10.0 (0.39) 226.0 (8.90)
MPAR-NP174384 40 12.0 (0.47) 16.0 (0.63) 40.0 (1.57) 16.0 (0.63) 25.0 (0.98) 12.0 (0.47) 257.5 (10.14) (3)
MPAR-NP174386 63 16.0 (0.63) 21.0 (0.82) 51.0 (2.01) 21.0 (0.82) 32.0 (0.26) 16.0 (0.63) 328.3 (12.92)
(1) Material is die cast aluminum. Contains no copper, PTFE, or silicone.
(2) Tolerance for this dimension is ±0.2 mm (±0.0079 in.).
(3) Add 13 mm (0.51 in.) for catalog number MPAR-x2xxxF-Vxx.
W
RF OF
WR
ØD
H
H
D B OF (2) RF (2) W (3) WR (4) SL+
Frame
MPAR-NP31748 40 12.0 (0.47) (6) 33.5 (1.32) 36.0 (1.42) 30.5 (1.20) 17.5 (0.69) 16.0 (0.63) 12.0 (0.47) 257.5 (10.14) (7)
MPAR-NP31750 63 16.0 (0.63) (6) 48.0 (1.89) 50.0 (1.97) 44.5 (1.75) 22.5 (0.88) 21.0 (0.82) 15.0 (0.89) 328.3 (12.92)
P
RF S
OF
ØD
ØCB C
H TH
B
ØHD
LS
WS
LO
Bulletin TLAR In-line Base Plate WO
Bulletin MPAR In-line
Bulletin MPAR Parallel
H HD LS
D B (2) C CB LO
Frame
Cat. No. (1) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
js14 H13 js14
MPAR-NP31740 32 10.0 (3) 8.50 N/A 11.0 32.0 6.6 31.0 18.0
(0.39) (0.33) (0.43) (1.26) (0.26) (1.22) (0.71)
MPAR-NP31741 40 12.0 (4) 18.5 (5) N/A 11.0 46.0 (5) 6.6 35.0 22.0
(0.47) (0.73) (0.43) (1.81) (0.26) (1.38) (0.86)
MPAR-NP31743 63 16.0 (4) 18.5 (5) 27.0 15.0 58.0 (5) 9.0 50.0 35.0
(0.63) (0.73) (1.06) (0.59) (2.28) (0.35) (1.97) (1.38)
(1) Frame 32 and 40 material is high-alloy steel. Frame 63 material is nodular graphite cast iron. Contains no copper, PTFE, or silicone.
(2) Tolerance for this dimension is ±0.8 mm (±0.0315 in.).
(3) Tolerance for this dimension is +0.013 mm (±0.00051 in.).
(4) Tolerance for this dimension is +0.015 mm (±0.00059 in.).
(5) This dimension includes base plate provided with frame 40 and frame 63 foot mount attachments.
OF P (1) WS
RF S (2) TH WO
Frame
MPAR-NP31741 40 24.0 16.0 17.0 12.0 20.0 (3) (4) 54.0 41.0
(0.94) (0.63) (0.67) (0.47) (0.79) (2.12) (1.61)
MPAR-NP31743 63 37.0 21.0 22.0 15.0 20.0 (5) (4) 67.0 52.0
(1.45) (0.82) (0.86) (0.59) (0.79) (2.64) (2.05)
RF
Attachment includes
• 1 Swivel flange with
ØD spherical bearing
+ = Plus Stroke Length C A • 4 Mounting screws
H B
SL+
LE
HB FL
Attachment includes:
Bulletin TLAR In-line • 1 Clevis foot RF S1
Bulletin MPAR In-line • 1 Pivot pin (2)
UK RG
Bulletin MPAR Parallel • 1 Retaining clip UX
Frame
CL CM EK FL GL HB LE MR RF RG S1 UK UX
Cat. No. (1) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
MPAR- 28.0 14.1 10.0 32.0 16.0 6.8 24.0 12.0 42.0 20.0 4.8 56.0 36.0
32
NA31761 (1.10) (0.56) (0.39) (1.26) (0.63) (0.27) (0.94) (0.47) (1.65) (0.79) (0.19) (2.20) (1.42)
MPAR- 30.0 16.1 12.0 36.0 20.0 6.8 26.0 14.0 44.0 26.0 5.8 58.0 41.5
40
NA31762 (1.18) (0.63) (0.47) (1.42) (0.79) (0.27) (1.02) (0.55) (1.73) (1.02) (0.23) (2.28) (1.63)
MPAR- 40.0 21.1 16.0 50.0 25.0 9.0 38.0 17.0 56.0 31.0 7.8 70.0 47.0
63
NA31764 (1.57) (0.83) (0.63) (1.97) (0.98) (0.35) (1.50) (0.67) (2.20) (1.22) (0.31) (2.76) (1.85)
(1) Material is nodular graphite cast iron for environments requiring moderate corrosion resistance. Contains no copper, PTFE, or silicone.
(2) The pivot pin is secured against rotation with a dowel pin.
RF
Attachment includes
• 1 Swivel flange
ØD • 4 Mounting screws
+ = Plus Stroke Length C
H A
SL+
RF ØD
Attachment includes
• 1 Swivel flange
• 1 Pivot pin
C
+ = Plus Stroke Length H A • 2 Retaining clips
SL+ B • 4 Mounting screws
D A B
Cat. No. (2) C H (3) RF SL+
Frame
MPAR-NP174391 MPAR-NP176945 40 12.0 28.0 52.0 16.0 25.0 12.0 257.5 (4)
(0.47) (1.10) (2.05) (0.63) (0.98) (0.47) (10.14)
WS WO
LS
Attachment includes
LO 1 clevis foot.
OF P
RF ØD
Base Plate TH
D HD
Cat. No. (2) H LO LS OF P (3) RF TH WO WS
mm mm
Cat. No. (1)
Frame
Corrosion mm mm mm mm mm mm mm mm mm
(in.) (in.)
Resistant (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.)
D11 H13
10.0 32.0 6.6 31.0 18.0 21.0 25.8 10.0 8.0 ( 51.0 38.0
MPAR-NP33890 MPAR-NP161840 32 (0.39) (1.26) (0.26) (1.22) (0.71) (0.82) (1.01) (0.39) 0.31) (2.01) (1.49)
MPAR-NP33891 MPAR-NP161841 40 12.0 46.0 (4) 6.6 35.0 22.0 24.0 27.8 11.0 20.0 (4) 54.0 41.0
(0.47) (1.81) (0.26) (1.38) (0.86) (0.94) (1.09) (0.43) (0.79) (2.12) (1.61)
MPAR-NP33893 MPAR-NP161843 63 16.0 58.0 (4) 9.0 50.0 35.0 37.0 39.8 15.0 20.0 (4) 67.0 52.0
(0.63) (2.28) (0.35) (1.97) (1.38) (1.45) (1.56) (1.56) (0.79) (2.64) (2.05)
(1) Frame 32 and 40 material is high-alloy steel. Frame 63 material is nodular graphite cast iron. Contains no copper, PTFE, or silicone.
(2) Material is spacial steel casting, high corrosion protection stainless steel. Contains no copper, PTFE, or silicone.
(3) Tolerance for this dimension is -0.4 mm (-0.0157 in.).
(4) This dimension includes base plate provided with frame 40 and frame 63 foot mount attachments.
OF P
RF
ØD
C
H CBØ TH
B HDØ
+ = Plus Stroke Length LS WS
SL+ Base Plate LO WO
D (2) H (3)
Frame
B C CB HD LO LS
Cat. No. (1) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
MPAR-NP5562 40 12.0 14.30 (4) 20.0 10.0 46.0 (4) 5.5 35.0 22.0
(0.47) (0.56) (0.79) (0.39) (1.81) (0.21) (1.38) (0.86)
MPAR-NP5564 63 16.0 13.2 (4) 30.0 11.0 58.0 (4) 6.6 50.0 35.0
(0.63) (0.52) (1.18) (0.43) (2.28) (0.26) (1.97) (1.38)
(1) Frame 32 and 40 material is high-alloy steel. Frame 63 material is nodular graphite cast iron. Contains no copper, PTFE, or silicone.
(2) Tolerance for this dimension is -0.008 mm (-0.00031 in.).
(3) Tolerance for this dimension is ±0.5 mm (±0.0197 in.).
(4) This dimension includes base plate provided with frame 40 and frame 63 foot mount attachments.
RF (1)
Frame
OF P SL+ TH WO WS
Cat. No.
mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
MPAR-NP5562 40 24.0 27.8 15.0 257.5 (2) 20.0 (3) 54.0 41.0
(0.94) (1.09) (0.59) (10.14) (0.79) (2.12) (1.61)
C2 (5)
TM
C3 (5)
TL Ø TD XG
+ = Plus Stroke Length XV + 1/2
+ 1/2 = Plus Stroke Length UW
XJ +
Bulletin TLAR In-line
Bulletin MPAR In-line
Bulletin MPAR Parallel
TD Tightening
B1 C2 C3 TL TM UW XG XJ XV
Frame
Cat. No. (1) (2) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
Torque
e9 N•m (lb•in)
30.0 71.0 86.0 12.0 12.0 50.0 65.0 65.0 107 86.0 4.0
MPAR-NA163525 32 (1.18) (2.80) (3.39) (0.47) (0.47) (1.97) (2.56) (2.56) (4.21) (3.39) (35.4) (3)
32.0 87.0 105 16.0 16.0 63.0 75.0 74.5 130.5 102.5 8.0
MPAR-NA163526 40 (1.26) (3.43) (4.13) (0.63) (0.63) (2.48) (2.95) (2.93) (5.14) (4.04) (70.7) (3)
41.0 116 136 20.0 20.0 90.0 105 91.5 157.5 124.5 18.0
MPAR-NA163528 63 (1.61) (4.57) (5.35) (0.79) (0.79) (3.54) (4.13) (3.60) (6.20) (4.90) (159) (4)
(1) Material is tempered steel and subject to moderate corrosion stress.
(2) You can attach the trunnion mounting kit anywhere along the cylinder barrel.
(3) Tolerance for this tightening torque value is +1.0 N•m (+8.8 lb•in).
(4) Tolerance for this tightening torque value is +2.0 N•m (+17.7 lb•in).
(5) These dimensions are drawn to the trunnion support attachment as shown on page 164 (not included with the trunnion flange attachment).
32 7.0 6.6
(0.28) (0.26)
TR US 10.0 9.0
40
(0.39) (0.35)
63 10.0 9.0
2x Ø D1 THRU. (0.39) (0.35)
2x Ø AB
L1
H1
AT AH H2
SA+ B3
Bulletin TLAR In-line + = Plus Stroke Length B2
Bulletin MPAR In-line
XJ+ B1
Bulletin MPAR Parallel
AH AO AT AU B1 B2 B3 H1 H2 TR US XJ SA L1
Frame
Cat. No. (1) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
h9
10.0 27.0 14.2 11.0 25.0 32.0 22.0 45.0 9.0 14.0 6.6 18.0
MPAR-NA31768 32 (0.39) (1.06) (0.56) (0.43) (0.98) (1.26) (0.87) (1.77) (0.35) (0.55) (0.26) (0.71)
12.0 31.0 16.2 11.0 25.0 36.0 22.0 52.0 9.0 15.0 6.6 22.0
MPAR-NA31769 40 (0.47) (1.22) (0.64) (0.43) (0.98) (1.42) (0.87) (2.05) (0.35) (0.59) (0.26) (0.87)
16.0 41.0 21.2 15.0 36.0 50.0 38.0 71.0 12.0 20.0 9.0 28.0
MPAR-NA31771 63 (0.63) (1.61) (0.83) (0.59) (1.42) (1.97) (1.50) (2.80) (0.47) (0.79) (0.35) (1.10)
(1) Material is nodular graphite cast iron for environments requiring moderate corrosion resistance.
(2) Tolerance for this dimension is +0.2 mm (+0.008 in.).
(3) Tolerance for this dimension is ±0.3 mm (±0.012 in.) for Frame 32. Tolerance is js14 for Frame 40 and Frame 63.
(4) Tolerance for this dimension is ±0.5 mm (±0.019 in.) for Frame 32 and Frame 40.
(5) The pivot pin is secured against rotation with a dowel pin.
RF (1) RG (1)
Frame
MR S1 UK UX
Cat. No.
mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
12.5 40.0 29.0 4.8 56.0 45.0
MPAR-NA31768 32 (0.49) (1.57) (1.14) (0.19) (2.20) (1.77)
15.0 40.0 29.0 5.8 56.0 45.0
MPAR-NA31769 40 (0.59) (1.57) (1.14) (0.23) (2.20) (1.77)
18.0 57.0 47.0 7.8 75.0 65.0
MPAR-NA31771 63 (0.71) (2.24) (1.85) (0.31) (2.95) (2.56)
(1) Tolerance for this dimension is ±0.3 mm (±0.012 in.) for Frame 32. Tolerance is js14 for
Frame 40 and Frame 63.
These accessories apply to MP-Series and TL-Series electric cylinders. Components are designed to metric dimensions.
Inch dimensions are approximate conversions from millimeters. Dimensions without tolerances are for reference.
Rod-eye Attachment
CE
Dimensions are in mm (in.)
EF
D1
Attachment includes: EU Z AV
• 1 Rod eye
• 1 Hex nut FL1 FL2
Bulletin TLAR In-line
Bulletin MPAR In-line B1
EN CN KK
Bulletin MPAR Parallel
B2 CM KK D1 • 1 Rod clevis
• 1 Pivot pin (2)
• 1 Retaining clip
T1
CV LE Bulletin TLAR In-line Use the rod clevis in combination with the
CE Bulletin MPAR In-line rod eye for spherical mounting of cylinders.
5°
L4 L2 Bulletin MPAR Parallel
5°
L3
B3
B2 CK CM
B1 B3 CE CV D1 L2 L3 L4 LE T1
Frame
(1) Material is galvanized steel and subject to moderate corrosion stress. Contains no copper, PTFE, or silicone.
(2) The pivot pin is secured against rotation with a dowel pin.
D1 KK B2
CM
CK
CE CV
CK (3)
B1 B2 B3 CE (2) CM CV D1 LE (4) FL1
Frame
(1) mm (in.) KK
Cat. No. mm (in.) mm (in.) mm (in.) mm (in.) H9 mm (in.) mm (in.) mm (in.) mm (in.) mm
MPAR-NE6144 32 5.0 26.0 20.0 40.0 10.0 10.0 (5) 12.0 18.0 20.0 17 M10x1.25
(0.20) (1.02) (0.79) (1.57) (0.39) (0.39) (0.47) (0.71) (0.79)
MPAR-NE6145 40 6.0 31.0 24.0 48.0 12.0 12.0 (6) 14.0 20.0 24.0 19 M12x1.25
(0.24) (1.22) (0.94) (1.89) (0.47) (0.47) (0.55) (0.79) (0.94)
MPAR-NE6146 63 8.0 39.0 32.0 64.0 16.0 16.0 (6) 19.0 26.0 32.0 24 M16x1.50
(0.31) (1.54) (1.26) (2.52) (0.63) (0.63) (0.75) (1.02) (1.26)
(1) Material is galvanized steel and subject to moderate corrosion stress. Contains no copper, PTFE, or silicone.
(2) Tolerance for this dimension is ±0.4 (0.016 in.).
(3) Tolerance for this dimension is H9.
(4) Tolerance for this dimension is ±0.5 (0.019 in.).
(5) Tolerance for this dimension is B13.
(6) Tolerance for this dimension is a range between +0.7…+0.15 mm (+0.027…0.006 in.).
CK
CV CE
CK
B1 B2 B3 CE (2) CM CV D1 LE (3) FL1
Frame
MPAR- 32 5.0 27.0 20.0 40.0 10.0 10.0 (4) 12.0 18.0 20.0 16 M10x1.25
NE13569 (0.20) (1.06) (0.79) (1.57) (0.39) (0.39) (0.47) (0.71) (0.79)
MPAR- 40 6.0 33.0 24.0 48.0 12.0 12.0 (5) 14.0 20.0 24.0 18 M12x1.25
NE13570 (0.24) (1.30) (0.94) (1.89) (0.47) (0.47) (0.55) (0.79) (0.94)
MPAR- 63 8.0 43.0 32.0 64.0 16.0 16.0 (5) 19.0 26.0 32.0 24 M16x1.50
NE13571 (0.31) (1.69) (1.26) (2.52) (0.63) (0.63) (0.75) (1.02) (1.26)
(1) Material is high-alloy steel for environments requiring higher corrosion resistance. Contains no copper, PTFE, or silicone.
(2) Tolerance for this dimension is ±0.4 (0.016 in.).
(3) Tolerance for this dimension is ±0.5 (0.019 in.).
(4) Tolerance for this dimension is B13.
(5) Tolerance for this dimension is a range between +0.7…+0.15 mm (+0.027…0.006 in.).
B3
B1
A
Attachment includes: D1
• 1 Flange plate H2
• 1 Threaded coupling H1
T1
Bulletin TLAR In-line
Bulletin MPAR In-line KK
Bulletin MPAR Parallel SECTION A - A D2
D3
B1 B2 B3 B4 D1 (3) D2 H1 H2 T1 FL1
Frame
Cat. No. (1) (2) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm KK
H13
40.0 35.0 30.0 25.0 17.0 26.0 5.5 20.0 10.0 0.10
MPAR-NE36125 32 15 M10x1.25
(1.57) (1.38) (1.18) (0.98) (0.67) (1.02) (0.22) (0.79) (0.39) (0.004)
50.0 40.0 40.0 30.0 17.0 26.0 5.5 22.0 12.0 0.10
MPAR-NE36126 40 15 M12x1.25
(1.97) (1.57) (1.57) (1.18) (0.67) (1.02) (0.22) (0.87) (0.47) (0.004)
60.0 45.0 48.0 33.0 22.0 34.0 6.6 25.0 12.0 0.10
MPAR-NE36127 63 19 M16x1.50
(2.36) (1.77) (1.89) (1.30) (0.87) (1.34) (0.26) (0.98) (0.47) (0.004)
(1) Material is galvanized steel and subject to moderate corrosion stress. Contains no copper, PTFE, or silicone.
(2) Coupling is for non-rotating piston rods with male threads. You can use these coupling pieces to connect a cylinder with a non-rotating piston rod to another component
with a defined orientation, without rotating either the cylinder or the other component.
(3) Tolerance for this dimension is -0.2 mm (-0.008 in.).
4°
4°
• 1 Self-aligning rod coupler
• 1 Hex nut
Bulletin TLAR In-line
Bulletin MPAR In-line Angular Compensation Radial Compensation of Central Axis
Bulletin MPAR Parallel
Frame
B1 D1 D2 D3 L1 L2 L3 L4 L5 L6
Cat. No. (1) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
5.0 21.4 32.0 13.8 69.5 49.5 9.0 34.0 23.0 31.0
MPAR- NE6140 32 (0.20) (0.84) (1.26) (0.54) (2.74) (1.95) (0.35) (1.34) (0.91) (1.22)
6.0 21.4 32.0 13.8 74.5 50.5 10.0 34.0 24.0 32.0
MPAR-NE6141 40 (0.24) (0.84) (1.26) (0.54) (2.93) (1.99) (0.39) (1.34) (0.94) (1.26)
8.0 33.8 45.0 22.0 103 71.0 10.0 53.0 32.0 44.5
MPAR-NE6142 63 (0.31) (1.33) (1.77) (0.87) (4.06) (2.80) (0.39) (2.09) (1.26) (1.75)
Rod guides protect ISO standard cylinders from torsion when subjected to radial or torsional side loads. They provide
high-precision guidance for workpiece handling and other handling applications.
Material Specifications
1 2 3 4 5
Recirculating
Ball-bearing Guide
A = Cantilever Extension
X = Distance for Center of Gravity of Working Load
S = Center of Gravity of Working Load
400
350
300
250
F (N)
200
150
100
50
400
350
300
250
F (N)
200
150
100
50
400
350
300
250
F (N)
200
150
100
50
D3
Bulletin TLAR In-line L12
Bulletin MPAR In-line
Bulletin MPAR Parallel
L15
D4 L12
L13
SECTION A - A You can drill additional mounting
Compensating Coupling for L14
Radial and Axial Misalignment holes along these axes as required.
L4
B2 L5 L6 B1
D6 FL1
H2
D2 H4
L12 D1 KK B4 H1 H3
B3
D2 mm (in.) KK
mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) h6 mm (in.) mm (in.) mm (in.) mm (in.)
32 50.0 45.0 74.0 50.5 44.0 M6 11.0 6.6 12.0 97.0 (4) 90.0 61.0 78.0 M10x1.25
(1.97) (1.77) (2.91) (1.99) (1.73) (0.43) (0.26) (0.47) (3.82) (3.54) (2.40) (3.07)
40 58.0 54.0 87.0 58.5 44.0 M6 11.0 6.6 16.0 115 (4) 110 69.0 84.0 M12x1.25
(2.28) (2.13) (3.43) (2.30) (1.73) (0.43) (0.26) (0.63) (4.53) (4.33) (2.72) (3.31)
63 85.0 80.0 119 85.5 60.0 M8 15.0 9.0 20.0 152 (5) 145 100 105 M16x1.50
(3.35) (3.15) (4.69) (3.37) (2.36) (0.59) (0.35) (0.79) (5.98) (5.71) (3.94) (4.13)
32 155 67.0 (2) 125 24.0 76.0 20.0 12.0 4.3 32.5 70.3 78.0 6.5 12.0 15
(6.10) (2.64) (4.92) (0.94) (2.99) (0.79) (0.47) (0.17) (1.28) (2.77) (3.07) (0.26) (0.47)
40 170 75.0 (2) 140 28.0 81.0 22.0 12.0 11.0 38.0 84.0 – 6.5 14.0 15
(6.69) (2.95) (5.51) (1.10) (3.19) (0.87) (0.47) (0.43) (1.50) (3.31) (0.26) (0.55)
63 220 89.0 (3) 182 34.0 111 25.0 15.0 15.3 56.5 105 – 9.0 16.0 19
(8.66) (3.50) (7.17) (1.34) (4.37) (0.98) (0.59) (0.60) (2.22) (4.13) (0.35) (0.63)
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your actuator. For questions regarding product
availability, contact your Allen-Bradley distributor.
The Bulletin MPAI electric cylinders are available in standard and front trunnion mount configurations. The standard
mount cylinders provide tapped holes for mounting attachments. The front trunnion mount cylinders are compatible only
with the rod-end attachments.
Mounting Attachments
Accessory Item Description Dimensions
1 Mounting plates Includes two mounting plates and mounting hardware. page 196
Rear clevis mounting kit Includes replacement gasket to maintain IP rating, end-cap
2 page 196
mounting bolts are reused.
3 Front flange mount For front face mounting. Includes mounting hardware. page 197
Needed to prevent piston rod from rotating when piston rod is
4 Anti-rotation option page 198
not connected to the load. Includes mounting hardware.
3 4
Rod-end Attachments
Accessory Item Description Dimensions
5 Rod eye Includes mounting hardware. page 199
Permits a swivelling movement of the cylinder in one plane.
6 Rod clevis page 199
Includes mounting hardware.
Electric cylinder life specifications, the total running performance (L), are based on a combination of tested and calculated
data. If the parameters of your application are different, your results could be different. The achievable running
performance (L) is a function of mean feed force (F), according to DIN 69051-4 as illustrated below. Refer to Motion
Analyzer software, version 4.8 or later, for assistance when making these calculations for determining the running
performance for your application.
Load (lb)
100,000 3937
Expected Life (millions of mm)
Frame 110
1000 39.37
100 3.937
Frame 83
10 0.3937
1 0.03937
0 2000 4000 6000 8000 10,000 12,000 14,000 16,000
Load (N)
Load = Mean cubic feed force. The underlying formula that
Life = Accumulated total travel running performance. Legend defines this value is:
All curves represent properly lubricated and maintained actuators.
10 mm Lead 3
Frame 110 C
The L10 expected life of a ball-screw linear actuator is expressed as the 5 mm Lead L 10 = P
F
linear travel distance that 90% of properly maintained ball-screws are 10 mm Lead
expected to meet or exceed. This is not a guarantee and this graph Frame 83 Where:
should be used only for estimation purposes. 5 mm Lead L10 = Travel life in m (in.)
C = Dynamic load rating N (lb)
F = Cubic mean applied load N (lb)
P = Screw lead mm (in.)
Load (lb)
0 450 899 1349 1798 2248 2698 3147 3597
10,000,000 393,700
1,000,000 39,370
Expected Life (millioins of mm)
10,000 393.7
Frame 83
1000 39.37
100 3.937
10 0.3937
0 2000 4000 6000 8000 10,000 12,000 14,000 16,000
Load (N)
Load = Mean cubic feed force. The underlying formula that
Life = Accumulated total travel running performance. Legend defines this value is:
All curves represent properly lubricated and maintained actuators.
10 mm Lead 3
Frame 110 C
The L10 expected life of a roller-screw linear actuator is expressed as 5 mm Lead L 10 = P
F
the linear travel distance that 90% of properly maintained roller-screws
are expected to meet or exceed. This is not a guarantee and this graph 10 mm Lead Where:
Frame 83
should be used only for estimation purposes. 5 mm Lead L10 = Travel life in millions of mm (in.)
C = Dynamic load rating N (lb)
F = Cubic mean applied load N (lb)
P = Screw lead mm (in.)
Application Guidelines
All Loads must be separately supported and guided (1). Loads should align along the
line-of-thrust rod motion. Side loading affects the life of the actuator. Actuators have been Grease
lubricated at the factory and are ready for installation. For moderate to light use, no lubrication Fitting
is required for the life of the actuator. For more severe duty use (higher loads and/or higher
duty cycles), periodic lubrication is necessary to achieve actuator expected life (2). Grease
should be added via the built-in grease fitting. Removing the cylinder from the machine is
seldom necessary (3).
(1) Bulletin MPAI actuators are not meant for use where side loading occurs.
(2) Refer to the MP-Series Heavy Duty Electric Cylinders Installation Instructions, publication MPAI-IN001, for lubrication guidelines and specifications.
(3) You can extend or retract the rod to a point where the grease fitting is more accessible.
Frame
Cat. No. N (lb) mm/s (in./s) mm/rev (in./rev) mm (in.) N (lb)
25 °C (77 °F) 40 °C (104 °F)
MPAI-x3xxxCM32x 4448 (1000) 4003 (900) 3176 (714) 279 (11) 5.0 (0.197) 7602 (1709)
83
MPAI-x3xxxEM32x 4003 (900) 2002 (450) 1588 (357) 559 (22) 10.0 (0.394) 152.4 mm (6.0 in.) 5400 (1214)
304.8 mm (12.0 in.)
MPAI-x4xxxCM32x 8896 (2000) 7784 (1750) 6179 (1389) 279 (11) 5.0 (0.197) (3) 15,100 (3395)
457.2 mm (18.0 in.)
110
MPAI-x4xxxEM32x 7784 (1750) 3892 (875) 3092 (695) 559 (22) 10.0 (0.394) 15,000 (3372)
(1) MPAI-A (230V) or MPAI-B (460V) replaces x in catalog number. Stroke length replaces xxx in catalog number.
(2) Characteristics when mounted to 279 x 279 x 12.7 mm (11 x 11 x 0.5 in.) aluminum mounting surface.
(3) For this stroke length, maximum speed is reduced by 33% for the 83 mm frame and by 12% for the 110 mm frame.
Mounting Accessories
Frame
Frame
Weight, approx. Weight, approx.
Accessory Cat. No. Accessory Cat. No.
g (oz) g (oz)
Rod-end Accessories
Frame
Frame
Electric Cylinder MPAI-xxxxxCM34x (1) MPAI-xxxxxEM34x (1) MPAI-xxxxxRM34x (2) MPAI-xxxxxSM34x (2)
Cat. No. N (lb) N (lb) N (lb) N (lb)
MPAI-x3xxxxM34x 5494 (1235) 2745 (617) 6423 (1444) 3212 (722)
MPAI-x4xxxxM34x 13,736 (3088) 6868 (1544) 16,063 (3611) 8029 (1805)
(1) MPAI-xxxxxCM34x is a 5 mm ball-screw actuator and MPAI-xxxxxEM34x is a 10 mm ball-screw actuator.
(2) MPAI-xxxxxRM34x is a 5 mm roller-screw actuator and MPAI-xxxxxSM34x is a 10 mm roller-screw actuator.
In vertical applications, an unpowered Bulletin MPAI electric cylinder requires a holding brake to maintain position if the
load on the actuator exceeds these values.
HD
AD
B
M8 x 1.25 x 8 (0.05 x 0.31)
Mounting Bolts (4x)
G1
Feedback Power/Brake
Connector Connector G2
AM
Grease Fitting WH
1.5 (0.06)
MP-Series Electric Cylinder Dimensions
1.5 (0.06)
L1 B
Flat for Wrench L2
See Detail A ZJ Dimensions ZJ and L7 are the length
L7 when piston rod is fully retracted.
26.72…26.97 34.73…34.98
(1.052…1.062) Detail A (1.367…1.377)
Across Flats Frame 83 Across Flats Detail A
Frame 110
MP-Series Heavy Duty Electric Cylinder Dimensions (frame 83)
(1) If ordering MPAI-A/B3xxxxM34A actuator with brake, add 47.7 mm (1.88 in.) to dimensions G2, L7, and ZJ.
(2) The tolerance for this dimension is +0.0, -0.038 mm (+0.0, -0.0015 in.).
MPAI-A/B4300xM32x 96.3 61.3 50.0 30.4 130.7 151.5 447.8 25.0 619.0 127.0 110.5 M8 x 1.25 x12 85.0 55.0 16.8 574.5
(3.79) (2.41) (1.97) (1.20) (5.15) (5.96) (17.63) (0.98) (24.37) (5.0) (4.35) (0.05 x 0.47) (3.35) (2.17) (0.66) (22.62)
(1) If ordering MPAI-A/B4xxxxM34A actuator with brake, add 47.7 mm (1.88 in.) to dimensions G2, L7, and ZJ.
(2) The tolerance for this dimension is +0.0, -0.038 mm (+0.0, -0.0015 in.).
Actuators are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions without tolerances are for reference.
193
Chapter 2
194
MP-Series Heavy Duty Electric Cylinder Trunnion Mount Dimensions (frame 83 and 110)
Chapter 2
HD
AD
MD
G1
Feedback Power/Brake MD
Connector AM G2
Connector
WH
1.5 (0.06)
Grease Fitting
L1
1.5 (0.06)
26.72…26.97 34.73…34.98
(1.052…1.062) Detail A
(1.367…1.377)
Across Flats Frame 83 Detail A
Across Flats
Frame 110
MP-Series Heavy Duty Electric Cylinder Trunnion Mount Dimensions (frame 83)
(1) If ordering MPAI-A/B3xxxxM34B actuator with brake, add 47.7 mm (1.88 in.) to dimensions G2, L7, and ZJ.
(2) The tolerance for this dimension is +0.0, -0.038 mm (+0.0, -0.0015 in.).
MP-Series Heavy Duty Electric Cylinder Trunnion Mount Dimensions (frame 110)
MPAI-A/B4300xM32x 96.3 61.3 30.4 130.7 151.5 619.0 127.0 22.2 110.5 M8 x 1.25 x12 20.05 6.25 16.8 574.5
(3.79) (2.41) (1.20) (5.15) (5.96) (24.37) (5.0) (0.87) (4.35) (0.05 x 0.47) (0.79) (0.25) (0.66) (22.62)
(1) If ordering MPAI-A/B4xxxxM34B actuator with brake, add 47.7 mm (1.88 in.) to dimensions G2, L7, and ZJ.
(2) The tolerance for this dimension is +0.0, -0.038 mm (+0.0, -0.0015 in.).
Actuators are designed to metric dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions without tolerances are for reference.
195
Chapter 2
Chapter 2 Linear Motion
These accessories apply to standard-mount electric cylinders. Components are designed to metric dimensions. Inch
dimensions are approximate conversions from millimeters. Dimensions without tolerances are for reference.
SW W
X FL D P HP SW W H
Frame
Cylinder Shown
for Reference
W
Attachment includes
ØD replacement gasket.
W H
Cat. No. (1) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
E R
E FB MF R TF UF
Cat. No. (1) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
The Bulletin MPAI actuator design lets the extending rod rotate. This provides simple setup of the actuator letting you
rotate the rod and thread it in and out of the actuator for mechanical attachment or system testing. This feature also
requires that the rod be kept from rotating when used in it's dedicated application for proper linear motion. In most
applications, for example, where the load is coupled to linear bearings or some support device, the load cannot rotate and
thus provides anti-rotation for the extending actuator rod. For applications where the load is free to rotate, Allen-Bradley
offers the anti-rotation option as shown on page 198.
IMPORTANT The anti-rotation option is not a guide or support mechanism. It is intended only as an anti-rotation device.
3 2
MH H
X L AL BL DL W CW EW FW H MH
Cat. No.
mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
257.6
MPAI-NE30215 (10.14)
105.2 410.0 16.1 89.0 12.7 72.3 15.9 57.0 69.7 62.7 38.1
MPAI-NE30230 83 (4.14) (16.14) (0.63) (3.50) (0.50) (2.85) (0.63) (2.24) (2.74) (2.47) (1.50)
562.4
MPAI-NE30245 (22.14)
260.9
MPAI-NE40215 (10.27)
108.5 413.3 15.5 93.0 12.7 85.7 19.8 70.5 83.2 62.7 45.9
MPAI-NE40230 110 (4.27) (16.27) (0.61) (3.66) (0.50) (3.37) (0.78) (2.78) (3.28) (2.47) (1.81)
565.7
MPAI-NE40245 (22.27)
These accessories apply to standard and front trunnion-mount electric cylinders. Components are designed to metric
dimensions. Inch dimensions are approximate conversions from millimeters. Dimensions without tolerances are for
reference.
Rod-eye Attachment
Dimensions are in mm (in.)
GAP ØD SW
10°
D P L W SW GAP
Cat. No. (1) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
IMPORTANT The spherical rod-eye attachment must be used with an anti-rotation option or the load that the actuator is attached
to must be kept from rotating. Without one of these two methods, the spherical rod-eye will let the actuator rod rotate
and result in inaccurate positioning due to lost rotational motion.
B2
CM
CK
GAP
Piston Rod Cylinder
CV
Shown for Reference
Attachment includes:
B3
• 1 Rod clevis
• 1 Hinged spring pin
• 1 Hex nut
CK
B2 B3 CM CV LE L P GAP
Frame
Cat. No. (1) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
H9
40.0 32.0 16.0 16.0 19.0 32.0 72.0 17.3 3.0…19.0
MPAI-NE304 83 (1.57) (1.26) (0.63) (0.63) (0.75) (1.26) (2.83) (0.68) (0.12…0.75)
48.0 40.0 20.0 20.0 25.0 40.0 90.0 16.8 3.0…24.5
MPAI-NE404 110 (1.89) (1.57) (0.79) (0.79) (0.98) (1.57) (3.54) (0.66) (0.12…0.96)
(1) Material is galvanized steel.
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your actuator. For questions regarding product
availability, contact your Allen-Bradley distributor.
Notes:
LDC-Series linear motors are equipped with SpeedTec-ready DIN connectors. However, these motors have incremental
encoders and must use threaded DIN (M4) feedback cables in non-flex applications. This is due to the number of
conductors required for incremental encoder connections.
SpeedTec-ready
DIN Connectors • LDC-Cxxxxxx linear motors • 2090-CFBM7DF-CDAFxx (continuous-flex) feedback cables
• Receives M4 and M7 cable plugs • 2090-CPWM7DF-16AAxx (standard) power-only cables
(remove the O-ring for M7) • 2090-CPWM7DF-16AFxx (continuous-flex) power-only cables
• Attach M7 cable plug with one-quarter turn
Threaded DIN (M4) Cable Plug
• Attach M4 cable plug with 5…6 turns
These performance specifications apply to all LDC-Series iron core linear motors.
Dielectric rating of motor power connections (U,V,W), to ground for 1.0 s (1) 2500V AC rms 50/60 Hz
Motor performance specifications are with sinusoidal commutation. Cooling options include NC
(no cooling), AC (air cooling), and WC (water cooling).
Resistance p-p @ 20 °C (68 °F) (5) (7) Ohms R20 2.256 1.128 4.51
Resistance p-p @ 20 °C (68 °F) (5) (7) Ohms R20 3.76 1.88 7.52 1.25 11.28
207
Chapter 2
LDC-Series Iron Core Linear Motors (75 mm frame size)
208
LDC-C075200-DxTxx LDC-C075200-ExTxx LDC-C075300-DxTxx LDC-C075300-ExTxx LDC-C075400-DxTxx LDC-C075400-ExTxx
Chapter 2
Thermal resistance °C/W Rth 0.58 0.37 0.26 0.58 0.37 0.26 0.39 0.25 0.17 0.39 0.25 0.17 0.29 0.19 0.13 0.29 0.19 0.13
Apk 7.7 9.6 11.5 3.8 4.8 5.7 11.5 14.4 17.2 3.8 4.8 5.7 15.3 19.1 23.0 7.7 9.6 11.5
Current, continuous (1) (2) (3) (6) Ic (5.4) (6.8) (8.1) (2.7) (3.4) (4.1) (8.1) (10.2) (12.2) (2.7) (3.4) (4.1) (10.8) (13.5) (16.2) (5.4) (6.8) (8.1)
(Arms)
Resistance p-p @ 20 °C (68 °F) (5) (7) Ohms R20 2.47 9.88 1.65 14.82 1.24 4.94
(1) Coils at maximum temperature, 130 °C (266 °F), mounted to an aluminium heat sink whose area is noted in table on page 212, and at 40 °C (104 °F) ambient.
(2) Continuous force and current based on coil moving with all phases sharing the same load in sinusoidal commutation.
(3) For standstill conditions, multiply continuous force and continuous current by 0.9.
(4) Calculated at 20% duty cycle for 1.0 second max. Some applications may produce significantly higher peak forces. Call Applications Engineering (631.344.6600) for details.
(5) Winding parameters listed are measured line-to-line (phase-to-phase).
(6) Currents and voltages listed are measured 0-peak of the sine wave unless noted as rms.
(7) Specifications are ±10%. Phase-to-phase inductance is ±30%.
(8) All specifications are at the standard reference air gap as shown in the drawing on page 214 and page 216.
Apk 11.1 13.9 16.7 3.7 4.6 5.6 14.8 18.5 22.2 7.4 9.3 11.1 22.2 27.8 33.3 11.1 13.9 16.7
Current, continuous (1) (2) (3) (6) Ic (7.9) (9.8) (11.8) (2.6) (3.3) (3.9) (10.5) (13.1) (15.7) (5.2) (6.5) (7.9) (15.7) (19.7) (23.6) (7.9) (9.8) (11.8)
(Arms)
Resistance p-p @ 20 °C (68 °F) (5) (7) Ohms R20 2.04 18.36 1.53 6.12 1.02 4.08
(1) Coils at maximum temperature, 130 °C (266 °F), mounted to an aluminium heat sink whose area is noted in table on page 212, and at 40 °C (104 °F) ambient.
(2) Continuous force and current based on coil moving with all phases sharing the same load in sinusoidal commutation.
(3) For standstill conditions, multiply continuous force and continuous current by 0.9.
(4) Calculated at 20% duty cycle for 1.0 second max. Some applications may produce significantly higher peak forces. Call Applications Engineering (631.344.6600) for details.
(5) Winding parameters listed are measured line-to-line (phase-to-phase).
(6) Currents and voltages listed are measured 0-peak of the sine wave unless noted as rms.
(7) Specifications are ±10%. Phase-to-phase inductance is ±30%.
(8) All specifications are at the standard reference air gap as shown in the drawing on page 214 and page 216.
209
Chapter 2
LDC-Series Iron Core Linear Motors (150 mm frame size)
210
LDC-C150400-DxTxx LDC-C150400-ExTxx LDC-C150600-DxTxx LDC-C150600-ExTxx
Chapter 2
Thermal resistance °C/W Rth 0.20 0.13 0.09 0.20 0.13 0.09 0.13 0.09 0.06 0.13 0.09 0.06
N/Apk 91.0 182.0 91.0 182.0
Force constant (5) (6) (7) Kf (20.5) (40.9) (20.5) (40.9)
(lbf/Apk)
Vp/m/s 107.5 215.0 107.5 215.0
Back EMF constant p-p (5) (6) (7) Ke (2.73) (5.46) (2.73) (5.46)
(Vp/in/s)
Apk 45.2 22.6 67.8 33.9
Current, peak (4) (6) Ip (32.0) (16.0) (47.9) (24.0)
(A rms)
Apk 14.1 17.6 21.1 7.0 8.8 10.6 21.1 26.4 31.7 10.6 13.2 15.8
Current, continuous (1) (2) (3) (6) Ic (10.0) (12.4) (14.9) (5.0) (6.2) (7.5) (14.9) (18.7) (22.4) (7.5) (9.3) (11.2)
(Arms)
Resistance p-p @ 20 °C (68 °F) (5) (7) Ohms R20 2.12 8.48 1.41 5.65
N Fa 7860 11790
Magnetic attraction (8) (lbf) (1768) (2652)
(1) Coils at maximum temperature, 130 °C (266 °F), mounted to an aluminium heat sink whose area is noted in table on page 212, and at 40 °C (104 °F) ambient.
(2) Continuous force and current based on coil moving with all phases sharing the same load in sinusoidal commutation.
(3) For standstill conditions, multiply continuous force and continuous current by 0.9.
(4) Calculated at 20% duty cycle for 1.0 second max. Some applications may produce significantly higher peak forces. Call Applications Engineering (631.344.6600) for details.
(5) Winding parameters listed are measured line-to-line (phase-to-phase).
(6) Currents and voltages listed are measured 0-peak of the sine wave unless noted as rms.
Cat. No. Cat. No. Air Flow Rate (1) Water Flow Rate (2)
Coil Cooling Plate L/min (ft3/hr) bar (psi)
LDC-C030100-xxxxx LDC-030-100-CP N/A (3) N/A (3)
LDC-C030200-xxxxx LDC-030-200-CP N/A (3) N/A (3)
LDC-C050100-xxxxx LCC-050-100-CP N/A (3) 0.41 (6)
(1) These are the flow rates required to maintain air pressure at 0.689 bar (10 lb/in.2).
(2) These are the flow rates required to maintain water pressure at 3.8 L/min (1 gal/min).
(3) This flow rate is not available. Call Application Engineering (631-344-6600) for assistance.
(4) These are the flow rates required to maintain water pressure at 7.57 L/min (2 gal/min).
LDC-Series iron core linear motor components are designed to metric dimensions. Inch dimensions are conversions from
millimeters. Untoleranced dimensions are for reference.
A Cooling plate
33.65 assembly shown 45.72 ± 0.13
66.67 (1.800 ± 0.005)
(1.325) for reference.
(2.625)
30.00
(1.181) Hall Effect Module
Flying Leads
R (ref.)
W H Thermistor Cables
Flying Leads Magnet track
shown for
Motor Power reference.
M
Flying Leads
L 1000 ±20
M5 x 0.8 15 (0.59) total depth, (39.4 ±0.8) 31.24
threads start at 5 (0.20). (1.230)
See table on page 215 for flatness
See table for hole quantity. of coil mounting surface.
LDC-Series Iron Core Linear Motor Coil Dimensions
L 30.00
(1.181) 31.24
M5 x 0.8 15 (0.59) total depth, (1.230)
threads start at 5 (0.20). Encoder Connector Feedback Connector
See table for hole quantity. See table on page 215 for flatness
Power Connector of coil mounting surface.
LDC-C030/050/075/100xxx-xHTxx Motor Coil Dimensions
L W (1) A B C D E F H M R Hole
Cat. No.
mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) Qty
LDC-C030100-DHTxx 134.0 (5.28) 65.00 – – – – – – 15.00 25.00 60.00 4
LDC-C030200-xHTxx 234.0 (9.21) (2.559) 100.00 (3.937) 166.67 (6.562) – – – – (0.591) (0.984) (2.362) 8
LDC-C050100-DHTxx 134.0 (5.28) – – – – – – 4
85.00 25.00 30.00 80.00
LDC-C050200-xHTxx 234.0 (9.21) 100.00 (3.937) 166.67 (6.562) – – – – 8
(3.346) (0.984) (1.181) (3.150)
LDC-C050300-xHTxx 334.0 (13.15) 133.33 (5.249) 200.00 (7.874) 266.67 (10.499) – – – 10
LDC-C075200-xHTxx 234.0 (9.21) 100.00 (3.937) 166.67 (6.562) – – – – 8
40.00 35.00 105.00
LDC-C075300-xHTxx 334.0 (13.15) 110.00 133.33 (5.249) 200.00 (7.874) 266.67 (10.499) – – – 10
(4.331) (1.575) (1.378) (4.134)
LDC-C075400-xHTxx 434.0 (17.09) 133.33 (5.249) 233.33 (9.186) 300.00 (11.811) 366.67 (14.436) – – 12
LDC-C100300-xHTxx 334.0 (13.15) 133.33 (5.249) 200.00 (7.874) 266.67 (10.499) – – – 10
60.00 37.50 130.00
LDC-C100400-xHTxx 434.0 (17.09) 135.00 133.33 (5.249) 233.33 (9.186) 300.00 (11.811) 366.67 (14.436) – – 12
(5.315) (2.362) (1.476) (5.118)
LDC-C100600-xHTxx 634.0 (25.31) 133.33 (5.249) 233.33 (9.186) 333.33 (13.123) 433.33 (17.060) 500.00 (19.686) 566.66 (22.310) 16
(1) Tolerance for W dimension is +1.00 mm (+0.039 in.), -0.00 mm (-0.000 in.)
LDC-C030xxx-xHTxx LDC-C030xxx-xHTxx
LDC-C050xxx-xHTxx LDC-C050100-DHTxx 0.25 (0.01)
LDC-C075xxx-xHTxx 0.75 (18) LDC-C050200-xHTxx
LDC-C100300-xHTxx LDC-C050300-xHTxx 0.38 (0.15)
(1) Refer to Cable Specifications on page 217 for additional cable specifications.
215
Chapter 2
216
LDC-C0150xxx-xHT20 Motor Coil Dimensions (flying leads)
F Dimensions are in mm (in.)
Chapter 2
30.00 180.00
(1.181) (7.087)
185.00 +1.00 Hall Effect Module
- 0.00 120.00 Flying Leads Ref.
(4.724)
(7.283 +0.039 Magnet track
-0.000) 60.00 Thermistor Cables
shown for
(2.362) Flying Leads
reference.
Motor Power
Flying Leads
32.50 1000 ± 20
(1.280) L 31.24
(39.4 ± 0.8)
M5 x 0.8 15 (0.59) total depth, (1.230)
threads start at 5 (0.20). See table on page 217 for flatness
See table for hole quantity. of coil mounting surface.
180.00
600 (7.087)
120.00 (24)
185.00 +1.00 (4.724) 350 Ref.
-0.00 (13.9)
60.00 Magnet track
(7.283 +0.039
(2.362) shown for
-0.000)
reference.
L A B C D E F Hole
Cat. No.
mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) Qty
LDC-C150400-xHTxx 434.0 (17.09) 133.33 (5.249) 233.33 (9.186) 300.00 (11.811) 366.67 (14.436) – – 18
LDC-C150600-xHTxx 634.0 (25.31) 133.33 (5.249) 233.33 (9.186) 333.33 (13.123) 433.33 (17.060) 500.00 (19.686) 566.66 (22.310) 24
Cable Specifications
Gauge Cable Dia. Static Bend Radius Power Cable Gauge Flatness
Cable (1) Conductors Shield Type Cat. No.
mm2 (AWG) mm (in.) mm (in.) mm2 (AWG) mm/300 x 300 (in./12 x 12)
Power (2) 4 0.75 (18) Braid 7.0 (0.28) 18.0 (0.70) LDC-C150400-xHTxx 0.64 (0.025)
0.82 (18)
4 1.5 (16) Braid 8.0 (0.32) 17.0 (0.67) LDC-C150600-DHTxx
Power (2) 0.89 (0.035)
LDC-C150600-EHTxx 1.31 (16)
Power (2) 4 0.50 (20) Braid 6.4 (0.25) 17.0 (0.67)
217
Chapter 2
218
LDC-Series Iron Core Linear Motor Magnet Track Dimensions
Mounting Hole Ø 5.50 (0.216)
Dimensions Ø 9.50 (0.375) 5.0 (0.20)
Chapter 2
L
50.00 See table for hole quantity.
24.50 50.00 Dimensions are in mm (in.) (1.969)
(0.965) (1.969) H
N Places
Linear Motion
Ø 3.99 +0.03
M
-0.00
(0.157 +0.001
-0.000)
12.50
6.00 (0.492) T
N Places
(0.236) Y 25.00
Gap will result from setting the (0.984) See table for flatness of
plates to set up dimensions shown. Set-up Dimension coil mounting surface.
H T W
30.0 S
L Ø 6.35 (0.250)
M (1.18)
Ø 5.50 (0.216) OD copper
See table for quantity. 4.0 tubing
(0.157)
H M T S
L W A B C D E F Hole
Cat. No. mm mm mm mm
mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) Qty
(in.) (in.) (in.) (in.)
LDC-030-100-CP 134.0 (5.28) 38.00 – – – – – – 15.00 11.50 27.5 5.25 4
LDC-030-200-CP 234.0 (9.21) (1.496) 100.00 (3.937) 166.67 (6.562) – – – – (0.591) (0.453) (1.08) (0207) 8
LDC-Series Iron Core Linear Motor Coil Cooling Plate Dimensions
219
Chapter 2
220
Chapter 2
C
12.00 ± 0.13
B (0.472 ± 0.005)
A
66.67 33.65
(2.625) (1.325)
15.00 L 30.0
(0.591) (1.18)
Ø 9.525 (0.3750)
OD Copper Tubing
Ø 5.50 (0.216)
See table for hole quantity.
L A B C D E F Hole
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your actuator. For questions regarding product
availability, contact your Allen-Bradley distributor.
Cable Termination
0 = Flying leads
1 = Circular DIN connector
Cable Length
0 = 300 mm (12.45 in.)
1 = 600 mm (23.62in.)
2 = 1000 mm (39.37 in.)
Thermal Protection
T = PTC Thermal sensor and switch
Feedback
H = Hall effect (trapezoidal)
N = No feedback
Winding Code
D = D winding
E = E winding
Coil Length (1)
100 = 100 mm (4.15 in.) 400 = 400 mm (16.60 in.)
200 = 200 mm (8.30 in.) 600 = 600 mm (23.62 in.)
300 = 300 mm (12.45 in.)
Frame Size (1)
030 075150
050 100
Coil Designation
C = Standard coil
Motor Series
LDC = LDC-Series
(1) Not all combinations are available. Only the configurations as listed in LDC-Series Iron Core Linear Motor Performance Specifications on page 205 are available.
LDC-Series Iron Core Linear Motor Magnet Track and Cooling Plate Catalog Numbers
LDC - M xxx xxx LDC - xxx - xxx - CP
Magnet Track Length Cooling Plate
100 = 100 mm (4.15 in.) Coil Length
500 = 500 mm (19.68 in.) 100 = 100 mm (4.15 in.) 400 = 400 mm (16.60 in.)
Frame Size 200 = 200 mm (8.30 in.) 600 = 600 mm (23.62 in.)
030 075 150 300 = 300 mm (12.45 in.)
050 100 Frame Size
Magnet Plate Designation 030 075 150
M = Magnet plate 050 100
Motor Series Motor Series
LDC = LDC-Series LDC = LDC-Series
Notes:
LDL-Series linear motors are equipped with SpeedTec-ready DIN connectors. However, these motors have incremental
encoders and must use threaded DIN (M4) feedback cables in non-flex applications. This is due to the number of
conductors required for incremental encoder connections.
SpeedTec-ready
DIN Connectors • LDL-xxxxxxx linear motors • 2090-CFBM7DF-CDAFxx (continuous-flex) feedback cables
• Receives M4 and M7 cable plugs • 2090-CPWM7DF-xxAAxx (standard) power-only cables
(remove the O-ring for M7) • 2090-CPWM7DF-xxAFxx (continuous-flex) power-only cables
• Attach M7 cable plug with one-quarter turn
Threaded DIN (M4) Cable Plug
• Attach M4 cable plug with 5…6 turns
M4
Ø4
M4
Ø4
28.3 28.3
0(
0 (1
1.5
(1.11) (1.11)
7)
.57
)
Box, Cabinet Box, Cabinet Mounting Hole
Mounting Hole
Dielectric rating of motor power connections (U,V,W), to ground for 1.0 s (1) 1500V AC rms, 50/60 Hz
Cogging torque Zero
Force, continuous (1) (2) (3) (4) N (lbf) Fc 63 (14) 126 (28)
Current, peak (5) (7) Apk (A rms) Ip 9.9 (7.0) 19.9 (14.0) 9.9 (7.0)
Current, continuous (1) (2) (3) (4) Apk (Arms) Ic 3.0 (2.1) 6.0 (4.2) 3.0 (2.1)
Resistance p-p @ 20 °C (68 °F) (6) (8) Ohms R20 5.41 2.70 10.82
Force, continuous (1) (2) (3) (4) N (lbf) Fc 72 (16) 144 (32)
Current, peak (5) (7) Apk (A rms) Ip 9.9 (7.0) 19.9 (14.0) 9.9 (7.0)
Current, continuous (1) (2) (3) (4) Apk (Arms) Ic 3.0 (2.1) 6.0 (4.2) 3.0 (2.1)
Resistance p-p @ 20 °C (68 °F) (6) (8) Ohms R20 7.15 3.57 14.29
(1) Coils at maximum temperature, 130 °C (266 °F), mounted to an aluminium heat sink whose area is noted in table on page 231, and at 40 °C (104 °F) ambient.
(2) Continuous force and current based on coil moving with all phases sharing the same load in sinusoidal commutation.
(3) For standstill conditions, multiply continuous force and continuous current by 0.9.
(4) Coil mountings on either of the two narrow sides reduces continuous force by 10%.
(5) Calculated at 11% duty cycle for 1.0 second max. Some applications may produce significantly higher peak forces. Call Applications Engineering (631.344.6600) for details.
(6) Winding parameters listed are measured line-to-line (phase-to-phase).
(7) Currents and voltages listed are measured 0-peak of the sine wave unless noted as rms.
(8) Specifications are ±10%. Phase-to-phase inductance is ±30%.
Force, continuous (1) (2) (3) (4) N (lbf) Fc 96 (22) 191 (43)
Current, peak (5) (7) Apk (A rms) Ip 9.1 (6.4) 18.1 (12.8) 9.1 (6.4)
Current, continuous (1) (2) (3) (4) Apk (Arms) Ic 2.7 (1.9) 5.5 (3.9) 2.7 (1.9)
Resistance p-p @ 20 °C (68 °F) (6) (8) Ohms R20 7.11 3.56 14.22
Force, continuous (1) (2) (3) (4) N (lbf) Fc 287 (65) 383 (86)
Current, peak (5) (7) Apk (A rms) Ip 27.2 (19.2) 9.1 (6.4) 36.3 (25.6) 18.1 (12.8)
Current, continuous (1) (2) (3) (4) Apk (Arms) Ic 8.2 (5.8) 2.7 (1.9) 10.9 (7.7) 5.5 (3.9)
Resistance p-p @ 20 °C (68 °F) (6) (8) Ohms R20 2.37 21.33 1.78 7.11
(1) Coils at maximum temperature, 130 °C (266 °F), mounted to an aluminium heat sink whose area is noted in table on page 231, and at 40 °C (104 °F) ambient.
(2) Continuous force and current based on coil moving with all phases sharing the same load in sinusoidal commutation.
(3) For standstill conditions, multiply continuous force and continuous current by 0.9.
(4) Coil mountings on either of the two narrow sides reduces continuous force by 10%.
(5) Calculated at 11% duty cycle for 1.0 second max. Some applications may produce significantly higher peak forces. Call Applications Engineering (631.344.6600) for details.
(6) Winding parameters listed are measured line-to-line (phase-to-phase).
(7) Currents and voltages listed are measured 0-peak of the sine wave unless noted as rms.
(8) Specifications are ±10%. Phase-to-phase inductance is ±30%.
Force, continuous (1) (2) (3) (4) N (lbf) Fc 110 (25) 220 (49)
Current, peak (5) (7) Apk (A rms) Ip 9.1 (6.4) 18.1 (12.8) 9.1 (6.4)
Current, continuous (1) (2) (3) (4) Apk (Arms) Ic 2.7 (1.9) 5.5 (3.9) 2.7 (1.9)
Resistance p-p @ 20 °C (68 °F) (6) (8) Ohms R20 9.42 4.71 18.83
Force, continuous (1) (2) (3) (4) N (lbf) Fc 329 (74) 439 (99)
Current, peak (5) (7) Apk (A rms) Ip 27.2 (19.2) 9.1 (6.4) 36.3 (25.6) 18.1 (12.8)
Current, continuous (1) (2) (3) (4) Apk (Arms) Ic 8.2 (5.8) 2.7 (1.9) 10.9 (7.7) 5.5 (3.9)
Resistance p-p @ 20 °C (68 °F) (6) (8) Ohms R20 3.14 28.25 2.35 9.42
(1) Coils at maximum temperature, 130 °C (266 °F), mounted to an aluminium heat sink whose area is noted in table on page 231, and at 40 °C (104 °F) ambient.
(2) Continuous force and current based on coil moving with all phases sharing the same load in sinusoidal commutation.
(3) For standstill conditions, multiply continuous force and continuous current by 0.9.
(4) Coil mountings on either of the two narrow sides reduces continuous force by 10%.
(5) Calculated at 11% duty cycle for 1.0 second max. Some applications may produce significantly higher peak forces. Call Applications Engineering (631.344.6600) for details.
(6) Winding parameters listed are measured line-to-line (phase-to-phase).
(7) Currents and voltages listed are measured 0-peak of the sine wave unless noted as rms.
(8) Specifications are ±10%. Phase-to-phase inductance is ±30%.
Current, peak (5) (7) Apk (A rms) Ip 32.8 (23.2) 16.4 (11.6)
Current, continuous (1) (2) (3) (4) Apk (Arms) Ic 9.9 (7.0) 4.9 (3.5)
Resistance p-p @ 20 °C (68 °F) (6) (8) Ohms R20 2.31 9.24
Current, peak (5) (7) Apk (A rms) Ip 32.8 (23.2) 16.4 (11.6)
Current, continuous (1) (2) (3) (4) Apk (Arms) Ic 9.9 (7.0) 4.9 (3.5)
Resistance p-p @ 20 °C (68 °F) (6) (8) Ohms R20 3.06 12.25
(1) Coils at maximum temperature, 130 °C (266 °F), mounted to an aluminium heat sink whose area is noted in table on page 231, and at 40 °C (104 °F) ambient.
(2) Continuous force and current based on coil moving with all phases sharing the same load in sinusoidal commutation.
(3) For standstill conditions, multiply continuous force and continuous current by 0.9.
(4) Coil mountings on either of the two narrow sides reduces continuous force by 10%.
(5) Calculated at 11% duty cycle for 1.0 second max. Some applications may produce significantly higher peak forces. Call Applications Engineering (631.344.6600) for details.
(6) Winding parameters listed are measured line-to-line (phase-to-phase).
(7) Currents and voltages listed are measured 0-peak of the sine wave unless noted as rms.
(8) Specifications are ±10%. Phase-to-phase inductance is ±30%.
LDL-Series ironless linear motor components are designed to metric dimensions. Inch dimensions are conversions from
millimeters. Untoleranced dimensions are for reference.
232
F
Chapter 2
35.00 26.00
(1.378) (1.024)
Power Cable
4.50 L Flying Leads
(0.177) Mounting holes 1000 mm (39.37 in.)
M4 x 0.7 8.5 (0.33),
Mounting holes quantity A1.
60.00 22.00 Magnet Channel
M4 x 0.7 7 (0.28) (2.362) 38.00
typical both sides, Refer to table on page 233 for coil mounting surface flatness requirement. (0.866) shown for reference.
Typical (1.496)
quantity A2.
H 32.00 T
(1.260) 0.83±0.30
0.260 (0.010)
Coil Face Runout (T.I.R.) (0.033±.011)
Air Gap
Cable Specifications
233
Chapter 2
LDL-Series Ironless Linear Motor Magnet Channel Dimensions
234
L
Dimensions are in mm (in.)
Chapter 2
Y 25.00 G
(0.984) Set-up Dimension
9.50
M (0.374) H
Linear Motion
D
Refer to table for magnet channel mounting surface flatness requirement.
60.00
29.5 60.00 M6 x 1.0-6H thru
(2.362)
(1.16) (2.362) See table for hole quantity.
Mounting Hole Dimensions
N Places
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your actuator. For questions regarding product
availability, contact your Allen-Bradley distributor.
Cable Termination
0 = Flying leads
1 = Circular DIN connector
Cable Length
0 = 300 mm (12.45 in.)
1 = 600 mm (23.62in.)
2 = 1000 mm (39.37 in.)
Thermal Protection
T = PTC Thermal sensor and switch
Feedback
H = Hall effect (trapezoidal)
N = No feedback
Winding Code
D = D winding
E = E winding
Coil Length (1)
120 = 120 mm (4.72 in.)
240 = 240 mm (9.45 in.)
360 = 360 mm (14.17 in.)
480 = 480 mm (18.90 in.)
Frame Size (1)
030
050
075
Coil Designation
N = Standard coil
T = Thick coil
Motor Series
LDL = LDL-Series
(1) Not all combinations are available. Only the configurations as listed in LDL-Series Ironless Linear Motor Performance Specifications on page 225 are available.
Notes:
Controller Platforms
Use this chapter to become familiar with Rockwell Automation Integrated Architecture systems featuring programmable
automation controllers used for Kinetix Integrated Motion systems. It also includes information on programmable logic
controllers that are used for simpler, low-cost component-level motion control.
Topic Page
ControlLogix System Overview 237
CompactLogix System Overview 239
MicroLogix System Overview 241
SERCOS interface Modules 242
Analog Servo Modules 245
For more information regarding the ControlLogix platform, including the 1756-ENxTx EtherNet/IP modules, refer to the
ControlLogix Selection Guide, publication 1756-SG001.
ControlLogix Platform
1756-ENxTx EtherNet/IP Network Module
ControlLogix Chassis
Select the network module and number of controllers based on the needs of your application. This flexibility lets you share
system resources and divide applications across multiple controllers.
1756-ENxT
EtherNet/IP Module
PanelView Plus
Display Terminal
PowerFlex 755
Drive Modules
1585J-M8CBJM-x
Ethernet (shielded) Cable
For more information regarding the CompactLogix platform, refer to the CompactLogix Selection Guide, publication
1769-SG001.
CompactLogix Platform
RSLogix 5000
Software
CompactLogix
1769-L45x Controller
Ultra3000-SE
SERCOS interface
Servo Drive SERCOS Fiber-optic Ring
EtherNet/IP Network
RSLogix 5000
Kinetix 300 EtherNet/IP
Indexing Servo Drive Software
00
300
1585J-M8CBJM-x
Ethernet (shielded) Cable
command modes.
MicroLogix 1400
2090-CCMPCDS-23AAxx
OK
2071-Axx 2090-CCMDSDS-48AAxx
Kinetix 3 Component Drive-to-Drive Cables
Servo Drive
Sensor
For more information regarding the MicroLogix platform, refer to the MicroLogix Programmable Controllers Selection
Guide, publication 1761-SG001.
ControlLogix CompactLogix
1756-M03SE, 1756-M08SE and 1768-M04SE
1756-M16SE SERCOS interface Module
SERCOS interface Module
Certifications
• ControlLogix and CompactLogix SERCOS interface modules are UL Listed for U.S. and Canada. ControlLogix
SERCOS interface combination module is UL Listed and CSA Certified.
Refer to http://www.ab.com for more information.
• CE marked for all applicable directives.
General Specifications
Environmental Specifications
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering chart below to understand the configuration of your interface module. For questions regarding product
availability, contact your Allen-Bradley distributor.
1756 - M xx SE
SERCOS interface Module
Axis Capacity
03 = Up to 3 axes
08 = Up to 8 axes
16 = Up to 16 axes
Motion Module
Bulletin Number
1768 - M 04 SE
SERCOS interface Module
Axis Capacity
04 = Up to 4 axes
Motion Module
Bulletin Number
ControlLogix
1756-M02AE
1756-HYD02
1756-M02AS
Analog Servo Module
The 1756-M02AE and 1756-PM02AE modules are two-axis servo modules/PCI cards optimized for control of drives or actuators that
1756-M02AE require an ±10V velocity or torque reference input. Both provide a quadrature position feedback input and are compatible with a wide
range of quadrature output rotary and linear transducers.
The 1756-HYD02 module is a two-axis servo module optimized for control of hydraulic actuators that require an ±10V velocity reference
input. The 1756-HYD02 module provides a LDT feedback input. Typical actuators include hydraulic motors and hydraulic cylinders. The
1756-HYD02 module is compatible with a wide range of magnostrictive linear transducers (LDT) feedback devices.
1756-HYD02 Compatible LDTs include the following:
• Temposonics II: RPM or DPM • Santest: GYRP or GYRG
• Balluff: BTL-2-L2 or BTL-2-M2 • Gemco Quick-Stick II: 951 VP or 951 RS
The 1756-M02AS module is a two-axis servo module optimized for control of drives/actuators that require an ±10V velocity or torque
reference input. The 1756-M02AS module provides a Serial Synchronous Input (SSI) position feedback input and is compatible with a
wide range of SSI output rotary and linear transducers.
1756-M02AS SSI devices are available in many versions.
• Linear absolute and incremental encoders • Linear magnostrictive
• Rotary absolute and incremental encoders • Linear laser distance
• Linear absolute glass scales
Certifications
• ControlLogix modules are UL Listed and CSA Certified. Refer to http://www.ab.com for more information.
• CE marked for all applicable directives.
IMPORTANT The servo module must be in the same chassis as the ControlLogix controller that controls the servo module. If you
distribute motion control across different locations, place a ControlLogix controller in each chassis that has a servo
module.
This section contains general, input, output, servo loop, and environmental specifications for the ControlLogix analog
servo modules.
General Specifications
Input Specifications
Output Specifications
Environmental Specifications
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering chart below to understand the configuration of your servo module. For questions regarding product
availability, contact your Allen-Bradley distributor.
1756 - xx 02 xx
Encoder Type
AE = Analog encoder
AS = Synchronous serial interface
Axis Capacity
02 = Up to 2 axes
Module Type
M = Motion servo
HYD = Hydraulic servo
Bulletin Number
One 1756-TBxxH servo module terminal block is required for each 1756-M02AE, 1756-M02AS, or 1756-HYD02
module. The terminal block provides wire terminations so that performance can be controlled. It is removable and can be
installed by opening the servo module door and sliding it into place.
1756 - TB xxH
Options
CH = 36-position cage clamp
removable terminal board.
S6H = 36-position spring clamp
removable terminal board.
Terminal Block
Bulletin Number
The Kinetix 6200 and Kinetix 6500 drive families are part of the
Kinetix Integrated Motion solution.
These modular safe-speed servo drives help increase productivity and protect personnel with embedded safety features.
Modular design and control provides ease of maintenance and greater flexibility as the drive easily transitions from safe
torque-off to safe speed.
Topic Page
Kinetix 6200 and Kinetix 6500 Servo Drive Components 249
Kinetix 6000 Drive Component Compatibility 250
Kinetix 6200 and Kinetix 6500 Integrated Axis Modules 260
Kinetix 6200 and Kinetix 6500 Axis Modules 263
Kinetix 6200 and Kinetix 6500 Control Modules 266
Kinetix 6200 and Kinetix 6500 General System Specifications 267
Kinetix 6200 and Kinetix 6500 Features and Indicators 271
• Ethernet cables for Logix control and programming the safety configuration
Kinetix 6200 and Kinetix 6500 systems may also include any of these optional components:
• One or more IAM power modules used as a follower IAM, 2094-BCxx-Mxx-M (460V) and associated axis modules,
power rails, motors, and cables as required for the application.
• One shunt module, 2094-BSP2 with optional Bulletin 1394 external passive shunt module
• Slot-filler modules, 2094-PRF
• Bulletin 2094 Line Interface Module (LIM)
• Bulletin 2090 Resistive Brake Module (RBM)
In addition, 2094-BMxx-M AM power modules with SERCOS interface are supported on power rails with a
2094-BCxx-Mxx-S IAM drive module. Conversely, 2094-BMxx-S AM drive modules are supported on power rails with a
2094-BCxx-Mxx-M IAM power module with SERCOS interface.
IMPORTANT Kinetix 6500 EtherNet/IP control modules (catalog numbers 2094-EN02D-M01-Sx) are not compatible with IAM/AM
modules on the same Bulletin 2094 power rail where SERCOS interface is used.
For more information on the Kinetix 6000 IAM and AM modules, catalog numbers 2094-xCxx-Mxx-S and 2094-xMxx-S,
refer to Kinetix 6000 Multi-axis Servo Drives in Chapter 5.
For more information on the Bulletin 2094 power rails, shunt module, slot-filler module, RBM and LIM modules, refer to Motion
Control Accessories in Chapter 12.
These are typical hardware configurations for Kinetix 6200 and Kinetix 6500 modular drive systems.
2094-BSP2
Shunt Module
(optional component)
115/230V Control Power
2094-BCxx-Mxx-M
IAM Power Module 2094-PRF
with Slot Filler Module
MAIN VAC
Bulletin 2094 (required to fill
Control Module any unused slots)
2094-PRSx
Power Rail
2094-xLxxS
Line Interface Module
2094-BMxx-M
(optional component)
I/O Connections AM Power Modules (5) with
Bulletin 2094
Control Modules (5)
To Input Sensors 2090-K6CK-DxxM
and Control String Low Profile Connector Kits for I/O, Safety,
Motor Feedback, and Aux Feedback
Bulletin 2090
Motor Feedback Cables Bulletin 2090
Motor Power Cables
USA
www.ab.co
IN
Three-phase
Input Power
Line
Disconnect
Device
Input
Fusing
Single-phase
Control Power
Magnetic
Contactor 2090-XXLF-xxxx
Kinetix 6200 or Kinetix 6500 Multi-axis Servo Drive System
AC Line Filter
(required for CE)
2094-BSP2
Shunt Module
(optional component)
2094-BCxx-Mxx-M 2094-PRF
IAM Power Module Slot Filler Module
with (required to fill
Bulletin 2094 any unused slots)
Control Module
2094-PRSx
Power Rail
I/O Connections
To Input Sensors
and Control String
2094-BMxx-M
AM Power Modules (5) with
Bulletin 2094
2090-K6CK-DxxM Control Modules (5)
Low Profile Connector Kits for I/O, Safety,
Bulletin 2090 Motor Feedback, and Aux Feedback Bulletin 2090
Motor Feedback Cables Motor Power Cables
USA
www.ab.co
MADE
IN
In the system configuration below, the leader IAM power module is connected to the follower IAM module via the DC
common bus. When planning your panel layout, you must calculate the total bus capacitance of your DC common bus
system to make sure that the leader IAM power module is sized sufficiently to pre-charge the entire system. Refer to the
Kinetix 6200 and Kinetix 6500 Modular Servo Drive User Manual, publication 2094-UM002, when making this
calculation.
IMPORTANT If total bus capacitance of your system exceeds the leader IAM power module pre-charge rating, the IAM module
four-character display scrolls a power cycle user limit condition. If input power is applied, the display scrolls a power
cycle fault limit condition.
To correct this condition, you must replace the leader IAM power module with a larger module or decrease the total bus
capacitance by removing AM power modules.
2094-BCxx-Mxx-M 2094-PRF
IAM Power Module Slot Filler Module
with (required to fill
Bulletin 2094 any unused slots)
Control Module
2094-PRSx
Power Rail
2094-xLxxS
Line Interface Module
(optional component) 2094-BMxx-M
AM Power Modules (5) with
DC Common Bus Bulletin 2094 Control Modules (5)
2094-BCxx-Mxx-M 2094-PRF
IAM Power Module Slot Filler Module
with (required to fill
Bulletin 2094 any unused slots)
Control Module
2094-PRSx
Power Rail
2094-BMxx-M
AM Power Modules (5) with
Bulletin 2094 Control Modules (5)
Motors and other details common to both three-phase AC and DC common-bus configurations are removed.
The Kinetix 6200 control modules use SERCOS interface for configuring the Logix module and EtherNet/IP network for
access to the safety configuration tool.
In this example, an ethernet cable is connected to each control module when programming the safety configuration.
EtherNet/IP network connectivity is not required during runtime. Also shown are drive-to-drive SERCOS cable lengths
and catalog numbers when Kinetix 6000 and Kinetix 6200 drive modules exist on the same power rail.
Rx (front)
(2090-SCxxx-x) required only for programming
the 2094-SE02F-M00-S1
0.2 m (7.1 in.) safety configuration.
Kinetix 6200 Drive-to-Drive SERCOS Cables
2094-BCxx-Mxx-M
IAM Power Module
with
2094-SE02F-M00-Sx
Control Module
6200 6200 6200 6200 6200 6200
SAFE SPEED SAFE SPEED SAFE SPEED SAFE SPEED SAFE SPEED SAFE SPEED
2094-PRSx
Power Rail
Ethernet Cable
(1585J-M8TBJM-x)
2094-BMxx-M
AM Power Modules (5)
with 2094-SE02F-M00-Sx
Kinetix 6200 (top view) TX RX TX Kinetix 6000 (top view) Control Modules (5)
SERCOS Connectors RX
SERCOS Connectors
0.1 m 0.3 m
0.2 m (5.1 in.) 0.2 m (12.0 in.) 0.2 m
(7.1 in.) (7.1 in.) (7.1 in.)
The Kinetix 6500 control modules can use any Ethernet topology including star, linear, and device-level ring (DLR). DLR
is an ODVA standard and provides fault tolerant connectivity.
IMPORTANT Shielded Ethernet cable, catalog number 1585J-M8CBJM-x, is available in lengths up to 78 m (256 ft). However, the total
length of Ethernet cable connecting drive-to-drive, drive-to-controller, or drive-to-switch must not exceed 100 m (328 ft).
In this example, all devices are connected in linear topology. The Kinetix 6500 control module includes dual-port
connectivity. Devices without dual ports should include the 1783-ETAP module or be connected at the end of the line.
• Linear configurations support up to 64 devices.
• No redundancy. If any device becomes disconnected, all the devices downstream loose communication.
RSLogix 5000
Logix Platform
Software
(ControlLogix is shown)
2094-BCxx-Mxx-M
Integrated
Axis Module
with
2094-EN02D-M01-Sx
Control Module
2094-PRSx
Power Rail
1585J-M8CBJM-x
Ethernet (shielded) Cable
1585J-M8CBJM-OM3
0.3 m (1.0 ft) Ethernet cable 2094-BMxx-M Axis Modules (5) with
for drive-to-drive connections. 2094-EN02D-M01-Sx Control Modules (5)
PowerFlex 755
Drive Modules
In this example, the devices are connected by using device-level ring (DLR) topology. DLR topology is fault tolerant. For
example, if a device in the ring is disconnected, the rest of the devices in the ring continue to maintain communication.
• DLR configurations support up to 64 devices.
• All devices in a DLR ring should have dual-port connectivity or be connected in the ring by using a 1783-ETAP
module.
RSLogix 5000
ControlLogix Platform Software
1783-ETAP
Module
PowerFlex 755
Drive Module
755
2094-BCxx-Mxx-M
Integrated
Axis Module
with
2094-EN02D-M01-Sx
Control Module
2094-PRSx
Power Rail
1585J-M8CBJM-x
Ethernet (shielded) Cable
1585J-M8CBJM-OM3
2094-BMxx-M Axis Modules (5) with
0.3 m (1.0 ft) Ethernet cable
2094-EN02D-M01-Sx Control Modules (5)
for drive-to-drive connections.
In this example, the devices are connected by using star topology. Each device is connected directly to the switch, making
this topology fault tolerant. The 2094 power rail modules and other devices operate independently. The loss of one device
does not impact the operation of the other devices.
RSLogix 5000
ControlLogix Platform Software
2094-BCxx-Mxx-M
Integrated
Axis Module
with
2094-EN02D-M01-Sx
Control Module
2094-PRSx
Power Rail
1585J-M8CBJM-x
Ethernet (shielded) Cable
1585J-M8CBJM-OM3
0.3 m (1.0 ft) Ethernet cable 2094-BMxx-M Axis Modules (5) with
for drive-to-drive connections. 2094-EN02D-M01-Sx Control Modules (5)
755 755
I PK
I Cont
D = T PK x 100%
T
I Base
TPK
T
Time at Peak (TPK) The time at peak current (IPK) for a given loading profile. Must be less than or equal to TPKmax.
The level of peak current for a given loading profile. IPK must be less than or equal to the Peak Current Rating
Peak Current (IPK)
(TPKMAX) of the drive.
The level of current between the pulses of peak current for a given loading profile. IBase must be less than or
Base Current (IBase)
equal to the continuous current rating (ICont) of the drive.
The loading profile is comprised of IPK, IBase, TPK, and D (or T) values and completely specify the operation of
Loading Profile
the drive in an overload situation. These values are collectively defined as the Loading Profile of the drive.
Application Period (T) The sum of the times at IPK (TPK) and IBase.
50%
45%
40%
Maximum Duty Cycle (D max )
35% (1)
Legend
30%
I PK = 150%
25%
I PK = 200%
20%
15% I PK = 250%
10% Applies to these Bulletin 2094
power modules:
5% 2094-BC01-MP5-M, 2094-BMP5-M,
2094-BC01-M01-M, 2094-BM01-M,
0% 2094-BC02-M02-M, 2094-BM02-M,
2094-BC04-M03-M, 2094-BM03-M
0% 20% 40% 60% 80% 100%
50%
45%
40%
Maximum Duty Cycle (D max )
35% (1)
Legend
30%
I PK = 150%
25%
I PK = 200%
20%
Applies to these Bulletin 2094
15% power modules:
2094-BC07-M05-M, 2094-BM05-M
10%
5%
0%
0% 20% 40% 60% 80% 100%
Peak output current to bus (ADC ) (3) 22.6 A 56.4 A 103.8 A 203.2 A
Bus overvoltage 825V DC
Bus undervoltage 275V DC (when enabled) 425V DC (at the completion of pre-charge)
Internal shunt
Continuous power 50 W 200W
Peak power 5.6 kW 22.5W
Internal shunt resistor 115 Ω 27.75 Ω
Shunt on 805V DC
Shunt off 765V DC
Continuous power output to bus 6 kW 15 kW 27.6 kW 45 kW
Peak power output at 480V (3) 15 kW 37.5 kW 69 kW 135 kW
Efficiency 97%
Converter inductance 500 μH 125 μH 75 μH
Converter capacitance 110 μF 220 μF 940 μF 1410 μF
Short circuit current rating 200,000 A (rms) symmetrical
(1) All IAM power modules are limited to 2 contactor cycles per minute (with up to 4 axes), or 1 contactor cycle per minute (with 5…8 axes). The cycle capability also depends
on the converter power rating and the total system capacitance. To calculate cycle capability, refer to the Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives
User Manual, publication 2094-UM002.
(2) For eight axis systems with 230V AC control input voltage and 50 °C (122°F) ambient temperature the maximum inrush duration is less than 1/2 line cycle. To calculate the
maximum inrush duration for other configurations, refer to the Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual, publication 2094-UM002.
(3) Converter peak output duration equals 400 ms with a duty cycle of 16%.
Bulletin 2094
2094-BC01-M01-M Control Module F
(460V) is shown.
Bulletin 2094
Power Rail
E
2090-K6CK-D44M 51
D Low-profile Connector Kit for I/O, (2.0)
Safety, and Aux Feedback Connections
2090-K6CK-D15M
Low-profile Connector Kit
for Motor Feedback Connections
The IAM power module is shown mounted to the power rail with the control module attached.
A 196
B Dimensions are in (7.7)
millimeters (inches)
F
Bulletin 2094
2094-BC07-M05-M Control Module
IAM module is shown.
Bulletin 2094
Power Rail E
2090-K6CK-D44M 51
D Low-profile Connector Kit for I/O, (2.0)
Safety, and Aux Feedback Connections 2090-K6CK-D15M
Low-profile Connector Kit
for Motor Feedback Connections
The IAM power module is shown mounted to the power rail with the control module attached.
IAM Module A B D E F
Cat. No. mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
2094-BC04-M03-M
302 (11.9) 290 (11.4) 80 (3.1) 260 (10.25) 375 (14.7)
2094-BC07-M05-M
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your module. For questions regarding product
availability, contact your Allen-Bradley distributor.
2094 - B C xx - M xx - x
Power Module
M = Modular
Inverter Current Rating (peak of sine)
P5 = 4 A (460V input voltage)
01 = 9 A (460V input voltage)
02 = 15 A (460V input voltage)
03 = 30 A 460V input voltage)
05 = 49 A (460V input voltage)
Inverter (Axis Module)
Converter Power Rating
01 = 6 kW (460V input voltage)
02 = 15 kW (460V input voltage)
04 = 28 kW (460V input voltage)
07 = 45 kW (460V input voltage)
Converter
Input Voltage
B = 460V AC, 50/60 Hz
Bulletin Number
These specifications apply to the axis module specified in the column heading by catalog number and the same axis module
(inverter section) that resides within an IAM power module.
Bandwidth (1)
Velocity loop 500 Hz
Current loop 1300 Hz
PWM frequency 8 kHz 4 kHz
Nominal input voltage 650V DC
Continuous current (rms) (2) 2.8 A 6.1 A 10.3 A 21.2 A 34.6 A
Continuous current (sine) 0-pk (2) 4.0 A 8.6 A 14.6 A 30.0 A 48.9 A
A
Dimensions are in millimeters (inches) 70
B (2.76)
Bulletin 2094
Control Module F
2094-BM01-M
(460V) is shown.
Bulletin 2094
Power Rail
E
2090-K6CK-D44M 51
D Low-profile Connector Kit for I/O, (2.0)
Safety, and Aux Feedback Connections
2090-K6CK-D15M
Low-profile Connector Kit
for Motor Feedback Connections
The AM power module is shown mounted to the power rail with the control module attached.
AM Module A B D E F
Cat. No. mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
2094-BMP5-M
2094-BM01-M 302 (11.9) 290 (11.4) 80.0 (3.2) 260 (10.25) 285 (11.2)
2094-BM02-M
A 141
B Dimensions are in (5.5)
millimeters (inches)
Bulletin 2094
Control Module
F
2094-BM03-M
AM module is shown.
Bulletin 2094
Power Rail E
2090-K6CK-D44M 51
D Low-profile Connector Kit for I/O, (2.0)
Safety, and Aux Feedback Connections 2090-K6CK-D15M
Low-profile Connector Kit
for Motor Feedback Connections
The AM power module is shown mounted to the power rail with the control module attached.
AM Module A B D E F
Cat. No. mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
2094-BM03-M
302 (11.9) 290 (11.4) 80 (3.1) 260 (10.25) 375 (14.7)
2094-BM05-M
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your module. For questions regarding product
availability, contact your Allen-Bradley distributor.
2094 - BM xx - x
Power Module
M = Modular
Inverter Current Rating (peak of sine)
P5 = 4 A (460V input voltage)
01 = 9 A (460V input voltage)
02 = 15 A (460V input voltage)
03 = 30 A 460V input voltage)
05 = 49 A (460V input voltage)
Module Input Voltage
BM = 460V AC, 50/60 Hz
Bulletin Number
Control modules couple with IAM and AM power modules to provide drive status indicators and an interface to I/O,
communication, safety functionality, and feedback.
Safe Torque-off Safe Speed Monitoring
Feature
2094-EN02D-M01-S0 2094-SE02F-M00-S0 2094-EN02D-M01-S1 2094-SE02F-M00-S1
Ethernet ports 2 1 2 1
SERCOS ports – Rx/Tx – Rx/Tx
DC Bus status indicator √ √ √ √
Network status indicator √ – √ –
Module status indicator √ – √ –
Drive status indicator – √ – √
Comm status indicator – √ – √
Safety lock status indicator – – √ √
PORT 1 status indicator √ √ √ √
PORT 2 status indicator √ – √ –
IOD connector for I/O, safety, and √ √ √ √
auxiliary feedback
MF connector for motor feedback √ √ √ √
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your module. For questions regarding product
availability, contact your Allen-Bradley distributor.
2094 - xx 02 x - M0x - Sx
Safety Features
S0 = Safe torque-off
S1 = Safe speed monitoring
Control Features
M00 = SERCOS interface control
M01 = EtherNet/IP network control
Network Media
D = Twisted pair, dual port (EtherNet/IP network)
F = Fiber optic (SERCOS interface)
Axis Performance
02 = 500 µs
Network Communication
EN = EtherNet/IP network
SE = SERCOS interface
Bulletin Number
Environmental Specifications
Attribute Operational Range Storage Range (nonoperating)
Temperature, ambient 0…50 ° C (32…122 ° F) -40…70 ° C (-40…158 ° F)
Relative humidity 5…95% noncondensing 5…95% noncondensing
1000 m (3281 ft)
Altitude 3000 m (9843 ft) during transport
3000 m (9843 ft) with derating
5…55 Hz @ 0.35 mm (0.014 in.) double amplitude, continuous displacement; 55…500 Hz @ 2.0 g peak constant
Vibration acceleration (10 sweeps in each of 3 mutually perpendicular directions)
Shock 15 g, 11 ms half-sine pulse (3 pulses in each direction of 3 mutually perpendicular directions)
Weight Specifications
IAM Weight, approx. AM Weight, approx.
Cat. No. Cat. No.
Power Module kg (lb) Power Module kg (lb)
2094-BC01-MP5-M 5.67 (12.5) 2094-BMP5-M 3.18 (7.0)
2094-BC01-M01-M 5.67 (12.5) 2094-BM01-M 3.18 (7.0)
IAM AM
2094-BC02-M02-M 5.90 (13.0) 2094-BM02-M 3.40 (7.5)
(460V) (460V)
2094-BC04-M03-M 9.53 (21.0) 2094-BM03-M 5.44 (12.0)
2094-BC07-M05-M 9.98 (22.0) 2094-BM05-M 5.90 (13.0)
MPL-B3xxx… 90 (295.3)
MPL-B5xxx-S/M
MPL-B15xxx… 30 (98.4)
MPL-B45xxx-H
MPM-Bxxxxx-S/M 90 (295.3)
MPF-Bxxxx-S/M 90 (295.3)
MPS-Bxxxx-S/M 90 (295.3)
RDB-B215xx-7/3 30 (98.4)
RDB-B290xx-7/3 or 90 (295.3)
RDB-B410xx-7/3
Make sure the selected components are properly coordinated and meet acceptable codes including any requirements for
branch circuit protection. Evaluation of the short-circuit available current is critical and must be kept below the
short-circuit current rating of the circuit breaker.
Use class CC, J, L, or R fuses, with current rating as indicated in the table below. The following fuse examples and
Allen-Bradley circuit breakers are recommended for use with 2094-BCxx-Mxx-M IAM power modules when the Line
Interface Module (LIM) is not used.
IMPORTANT LIM Modules (catalog numbers 2094-ALxxS, 2094-BLxxS, and 2094-XL75S-Cx) provide branch circuit protection to the
IAM power module. Follow all applicable NEC and local codes.
Contactor Ratings
This table provides the recommended contactor ratings for IAM power modules installed without a LIM module.
IAM Power Contactor
Module Cat. No.
2094-BC01-MP5-M 100-C23x10 (AC coil)
2094-BC01-M01-M 100-C23Zx10 (DC coil)
100-C37x10 (AC coil)
2094-BC02-M02-M 100-C37Zx10 (DC coil)
100-C60x10 (AC coil)
2094-BC04-M03-M 100-C60Zx10 (DC coil)
100-C72x10 (AC coil)
2094-BC07-M05-M 100-C72Zx10 (DC coil)
Use this table to size an enclosure and calculate required ventilation for your Kinetix 6200 and Kinetix 6500 drive system.
Usage as % of Rated Power Output
Kinetix 6200 and Kinetix 6500 (1) (watts)
Drive Modules
20% 40% 60% 80% 100%
(2)
IAM (converter) module
2094-BC01-MP5-M 34
18 21 25 29
2094-BC01-M01-M 33
2094-BC02-M02-M 36 44 54 64 75
2094-BC04-M03-M 50 67 87 110 135
2094-BC07-M05-M 71 101 137 179 226
2094-BC02-M02-M with 4.52 Adc (=20%) converter DC current and 10.3 Arms (=100%) inverter output current.
Converter loss (36 W) + Inverter loss (142 W) = 178 W total power dissipation.
1
CTRL 1 Item Description
1 2 3 4
DC- W 7
1 2 3 4 5 6
L3 MBRK +
L2 COM
3 Contactor Enable (CED) connector
PWR 6
L1 DBRK -
DBRK +
4 Motor cable shield clamp
1 2
CONT EN-
3 CONT EN+
1 W
4
V 2
U
MBRK -
1 2 3 4 5 6
MBRK +
COM
PWR 3
DBRK - Item Description
DBRK +
4 Power-applied indicator
5 Mounting screw
1 Item Description
2 3
1 Guide pins (2x)
Kinetix 6200 4
2 Captive screw
Control Module, Top View 5
(2094-SE02F-M00-S1 module is shown) SERCOS communication rate and
3 optical power switches
4 SERCOS transmit (Tx) connector
5 SERCOS receive (Rx) connector
2
Kinetix 6200 6
Control Module, Front View Item Description
(2094-SE02F-M00-S1 module is shown)
7 8 9
6 Four-character status display
7 PORT 1 status Indicator
8 Drive status indicator
10
11 9 Comm status indicator
6200
SAFE SPEED
10 DC bus status indicator
Safety lock status indicator
11 (2094-SE02F-M00-S1 modules only)
12
I/O, safety, and aux feedback (IOD)
12 connector
13
Power module mounting screw access
13 hole
14
14 Motor feedback (MF) connector
Kinetix 6200 15
Control Module, Bottom View Item Description
(2094-SE02F-M00-S1 module is shown)
15 Ethernet (PORT1) connector
For connector kit options, refer to Breakout Components and Connector Kits beginning on page 442.
1
2 Item Description
Kinetix 6500 1 Guide pins (2x)
Control Module, Top View
(2094-EN02D-M01-S1 is shown) 2 Captive screw
2 Item Description
Item Description
Kinetix 6500 13 Ethernet (PORT1) connector
13
Control Module, Bottom View
(2094-EN02D-M01-S1 is shown) 14 Ethernet (PORT2) connector
14
Notes:
The Kinetix 6000 multi-axis servo drives are part of the Kinetix Integrated Motion solution.
Topic Page
Kinetix 6000 Servo Drive Components 275
Kinetix 6000 Integrated Axis Modules 284
Kinetix 6000 Axis Modules 289
Kinetix 6000 General System Specifications 293
Kinetix 6000 Connector, Indicator, and Switch Locations 299
Kinetix 6000 systems may also include any of these optional components:
• One or more integrated axis modules used as follower IAM, 2094-ACxx-Mxx-S (230V) or 2094-BCxx-Mxx-S
(460V) and associated axis modules, power rails, motors, and cables as required for the application
• One shunt module, 2094-BSP2 with optional Bulletin 1394 external passive shunt module
• Slot-filler modules, 2094-PRF
• Bulletin 2094 Line Interface Module (LIM)
• Bulletin 2090 Resistive Brake Module (RBM)
• Bulletin 1336 external active shunt module (dynamic brake)
The peak current ratings of the Kinetix 6000 AM modules (series A and B) are configured at the factory as 150% of
continuous current. You can program 460V (series B) AM modules and the equivalent IAM (inverter) modules, for up to
250% of continuous inverter current.
IMPORTANT Before your drive will deliver up to 250% peak performance, you must enable the peak enhancement feature by
configuring your drive by using DriveExplorer or RSLogix 5000 software.
Refer to the Kinetix 6000 Multi-axis Servo Drive User Manual, publication 2094-UM001, to recalculate torque and
accel/decel limit values, and paste them into the appropriate Axis Properties dialog box in RSLogix 5000 software.
For sizing your drive/motor combination by using series-B drives and the peak enhancement feature, use Motion Analyzer
software, version 4.6 or later.
2090-XXLF-xxxx
AC Line Filter
(required for CE)
Kinetix 6000 Multi-axis Servo Drive System
2094-BSP2
Three-Phase
Shunt Module
Input Power 115/230V (optional component)
Control Power
2094-xCxx-Mxx-S 2094-PRF
IAM Module Slot-filler Module
MAIN VAC
(required to fill
any unused slots)
2094-PRSx
Power Rail
2094-xLxxS 2094-xMxx-S
Line Interface Module Axis Modules (5)
(optional component)
I/O Connections
2090-K6CK-Dxxx
To Input Sensors
and Control String Low Profile Connector Kits for
I/O, Motor Feedback, and Aux Feedback
Bulletin 2090 Bulletin 2090
Motor Feedback Cables Motor Power Cables
075500
X XXXX
LDC-M
NO. XXXX
CAT. L NO.
SERIA
A
SERIES
(1) Kinetix 6000 drives are compatible with only TL-Series (Bulletin TLY-Axxxx-H) motors with incremental encoders.
(2) RDD-Series direct-drive motors require the 2090-K6CK-KENDAT low-profile feedback module for Kinetix 6000 drive applications.
Three-phase
Input Power
Line
Disconnect
Device
Input
Fusing
Single-phase
Control Power
Magnetic
Contactor 2090-XXLF-xxxx
Kinetix 6000 Multi-axis Servo Drive System
AC Line Filter
(required for CE)
2094-BSP2
Shunt Module
(optional component)
2094-xCxx-Mxx-S 2094-PRF
IAM Module Slot-filler Module
(required to fill
any unused slots)
2090-K6CK-Dxxx
Low Profile Connector Kits for
Bulletin 2090 I/O, Motor Feedback, and Aux Feedback Bulletin 2090
Motor Feedback Cables Motor Power Cables
USA
www.ab.co
MADE
IN
(1) Kinetix 6000 drives are compatible with only TL-Series (Bulletin TLY-Axxxx-H) motors with incremental encoders.
(2) RDD-Series direct-drive motors require the 2090-K6CK-KENDAT low-profile feedback module for Kinetix 6000 drive applications.
In the Kinetix 6000 system configuration below, the leader IAM module is connected to the follower IAM module via the
DC common bus. When planning your panel layout, you must calculate the total bus capacitance of your DC common bus
system to make sure that the leader IAM module is sized sufficiently to pre-charge the entire system. Refer to the Kinetix
6000 Servo Drive User Manual, publication 2094-UM001, when making this calculation.
IMPORTANT If total bus capacitance of your system exceeds the leader IAM module pre-charge rating, the IAM module
seven-segment status will display error code E90 (pre-charge timeout fault) if input power is applied.
To correct this condition, you must replace the leader IAM module with a larger module or decrease the total bus
capacitance by removing axis modules.
2090-XXLF-xxxx
Three-phase AC Line Filter
Input Power (required for CE)
2094-xCxx-Mxx-S
IAM Module
Common Bus Leader 2094-PRF
Slot-filler Module
(required to fill
any unused slots)
2094-PRSx
Power Rail
2094-xLxxS
Line Interface Module 2094-xMxx-S
(optional component) DC Common Bus Axis Modules (5)
2094-PRF
2094-xCxx-Mxx-S
Slot-filler Module
IAM Module
(required to fill
Common Bus Follower
any unused slots)
2094-PRSx
Power Rail
2094-xMxx-S
Axis Modules (5)
Motors and other details common to both three-phase AC and DC common-bus configurations are removed.
In this example, drive-to-drive SERCOS cable lengths and catalog numbers are shown for the Kinetix 6000 drives and
when Kinetix 6000 and Kinetix 6200 drive modules exist on the same power rail.
SERCOS interface
CP OK
Logix Platform RSLogix 5000
(ControlLogix is shown) Software
Tx (rear)
Rx (front)
2090-SCxxx-x
SERCOS Fiber-optic Cable
2094-xCxx-Mxx-S
IAM Module
2094-PRSx
Power Rail
2094-BMxx-S
Axis Modules (5)
IMPORTANT The peak enhancement feature requires the use of RSLogix 5000 software and drive firmware as specified below.
(1) Standard mode is enabled by default to preserve backward compatibility, but you can enable the Peak Enhanced mode to achieve increased peak
current performance. Refer to Kinetix 6000 IAM/AM Module Series Change on page 276 for information on enabling the Peak Enhanced mode.
IAM/AM Module Peak Inverter Current Rating Peak Converter Current Rating
Cat. No. Standard Peak Enhanced Series A Series B
2094-BC01-MP5-S 150% 250% 200% 250%
2094-BC01-M01-S 150% 250% 200% 250%
2094-BC02-M02-S 150% 250% 200% 250%
2094-BC04-M03-S 150% 250% 200% 250%
2094-BC07-M05-S 150% 200% 200% 300%
2094-BMP5-S 150% 250% N/A N/A
2094-BM01-S 150% 250% N/A N/A
2094-BM02-S 150% 250% N/A N/A
2094-BM03-S 150% 250% N/A N/A
2094-BM05-S 150% 200% N/A N/A
I PK
I Cont
D = T PK x 100%
T
I Base
TPK
T
Time at Peak (TPK) The time at peak current (IPK) for a given loading profile. Must be less than or equal to TPKmax.
The level of peak current for a given loading profile. IPK must be less than or equal to the Peak Current Rating
Peak Current (IPK)
(TPKMAX) of the drive.
The level of current between the pulses of peak current for a given loading profile. IBase must be less than or
Base Current (IBase)
equal to the continuous current rating (ICont) of the drive.
The loading profile is comprised of IPK, IBase, TPK, and D (or T) values and completely specify the operation of
Loading Profile
the drive in an overload situation. These values are collectively defined as the Loading Profile of the drive.
Application Period (T) The sum of the times at IPK (TPK) and IBase.
50%
45%
40%
Maximum Duty Cycle (D max )
35% (1)
Legend
30%
I PK = 150%
25%
I PK = 200%
20%
15% I PK = 250%
10% Applies to these Kinetix 6000 drives:
2094-BC01-MP5-S, 2094-BMP5-S,
5% 2094-BC01-M01-S, 2094-BM01-S,
2094-BC02-M02-S, 2094-BM02-S,
0% 2094-BC04-M03-S, 2094-BM03-S
0% 20% 40% 60% 80% 100%
50%
45%
40%
Maximum Duty Cycle (D max )
35% (1)
Legend
30%
I PK = 150%
25%
I PK = 200%
20%
Applies to these Kinetix 6000 drives:
15% 2094-BC07-M05-S, 2094-BM05-S
10%
5%
0%
0% 20% 40% 60% 80% 100%
(1) All 2094-xCxx IAM modules are limited to 2 contactor cycles per minute (with up to 4 axes), or 1 contactor cycle per minute (with 5…8 axes). The cycle capability also
depends on the converter power rating and the total system capacitance. To calculate cycle capability, refer to the Kinetix 6000 Multi-axis Servo Drives User Manual,
publication 2094-UM001.
(2) For eight axis systems with 230V AC control input voltage and 50 °C (122°F) ambient temperature the maximum inrush duration is less than 1/2 line cycle. To calculate the
maximum inrush duration for other configurations, refer to the Kinetix 6000 Multi-axis Servo Drives User Manual, publication 2094-UM001.
(3) Peak output current duration equals 250 ms.
A
125
B Dimensions are in mm (in.) (4.9)
8.9
(0.35)
F
2094-AC05-M01-S (230V) shown.
Power Rail
Important: Additional clearance below
the connector is necessary to provide
the recommended cable bend radius.
Modules are shown mounted to the power rail and the dimensions reflect that in the depth of the module.
IAM Module A B D E F
Cat. No. mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
2094-AC05-MP5-S
2094-AC05-M01-S 198 (7.8) 176 (7.0) 51 (2.0) 206 (8.2) 237 (9.3)
2094-AC09-M02-S
2094-BC01-MP5-S
2094-BC01-M01-S 272 (10.7) 249 (9.8) 0 (0) 256 (10.1) 287 (11.3)
2094-BC02-M02-S
8.9
(0.35)
IAM Module A B C E F
Cat. No. mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
2094-AC16-M03-S 125 (4.9)
198 (7.8) 176 (7.0) 302 (11.9) 420 (16.5)
2094-AC32-M05-S 196 (7.7)
2094-BC04-M03-S 256 (10.1) 374 (14.7)
272 (10.7) 249 (9.8) 196 (7.7)
2094-BC07-M05-S 318 (12.5) 436 (17.2)
IAM Module A B C E F
Cat. No. mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
2094-BC04-M03-S
272 (10.7) 249 (9.8) 196 (7.7) 256 (10.1) 374 (14.7)
2094-BC07-M05-S
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your module. For questions regarding product
availability, contact your Allen-Bradley distributor.
2094 - x C xx - M xx - x
Safety Feature
S = Safe-off
Inverter Current Rating (peak of sine)
P5 = 5 A (230V input voltage) P5 = 4 A (460V input voltage)
01 = 9 A (230V input voltage) 01 = 9 A (460V input voltage)
02 = 15 A (230V input voltage) 02 = 15 A (460V input voltage)
03 = 24 A (230V input voltage) 03 = 30 A 460V input voltage)
05 = 49 A (230V input voltage) 05 = 49 A (460V input voltage)
Inverter (Axis Module)
Converter Power Rating
05 = 3 kW (230V input voltage) 01 = 6 kW (460V input voltage)
09 = 6 kW (230V input voltage) 02 = 15 kW (460V input voltage)
16 = 11 kW (230V input voltage) 04 = 28 kW (460V input voltage)
32 = 23 kW (230V input voltage) 07 = 45 kW (460V input voltage)
Converter
Input Voltage
A = 230V AC, 50/60 Hz
B = 460V AC, 50/60 Hz
Bulletin Number
These specifications apply to the axis module specified in the column heading by catalog number and the same axis module
(inverter section) that resides within an IAM module.
Bandwidth (1)
Velocity loop 500 Hz
Current loop 1300 Hz
PWM frequency 8 kHz 4 kHz
Input voltage (nom) 325V DC
Continuous current (rms) 3.7 A 6.0 A 10.6 A 17.3 A 34.6 A
Continuous current (0-pk) 5.2 A 8.5 A 15.0 A 24.5 A 48.9 A
IMPORTANT The peak current ratings of the Kinetix 6000 AM modules (series A and B) are configured at the factory as 150% of
continuous current. You can program 2094-BMP5-S, 2094-BM01-S, 2094-BM02-S, and 2094-BM03-S series-B drives and
their equivalent IAM (inverter) modules, up to 250% of continuous inverter current. You can program the 2094-BM05-S
(AM module) and the 2094-BC07-M05-S (inverter) module up to 200% of continuous inverter current.
Bandwidth (1)
Velocity loop 500 Hz
Current loop 1300 Hz
PWM frequency 8 kHz 4 kHz
Nominal input voltage 650V DC
Continuous current (rms) (2) 2.8 A 6.1 A 10.3 A 21.2 A 34.6 A
Continuous current (sine) 0-pk (2) 4.0 A 8.6 A 14.6 A 30.0 A 48.9 A
A
B Dimensions are in mm (in.) 70
(2.76)
8.9
(0.35)
F
2094-AM01 (230V) shown.
Power Rail
Important: Additional clearance below
the connector is necessary to provide
the recommended cable bend radius.
Modules are shown mounted to the power rail and the dimensions reflect that in the depth of the module.
AM Module A B D E F
Cat. No. mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
2094-AMP5-S
2094-AM01-S 198 (7.8) 176 (7.0) 51 (2.0) 206 (8.2) 237 (9.3)
2094-AM02-S
2094-BMP5-S
2094-BM01-S 272 (10.7) 249 (9.8) 0 (0) 256 (10.1) 287 (11.3)
2094-BM02-S
A
B Dimensions are in mm (in.) C
8.9
(0.35)
Modules are shown mounted to the power rail and the dimensions reflect that in the depth of the module.
AM Module A B C E F
Cat. No. mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
2094-AM03-S
198 (7.8) 176 (7.0) 70 (2.8) 302 (11.9) 420 (16.5)
2094-AM05-S
2094-BM03-S 256 (10.1) 374 (14.7)
272 (10.7) 249 (9.8) 141 (5.5)
2094-BM05-S 318 (12.5) 436 (17.2)
AM Module A B C E F
Cat. No. mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
2094-BM03-S
272 (10.7) 249 (9.8) 141 (5.5) 256 (10.1) 374 (14.7)
2094-BM05-S
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your module. For questions regarding product
availability, contact your Allen-Bradley distributor.
2094 - x M xx - x
Safety Feature
S = Safe-off
Inverter Current Rating (peak of sine)
P5 = 5 A (230V input voltage) P5 = 4 A (460V input voltage)
01 = 9 A (230V input voltage) 01 = 9 A (460V input voltage)
02 = 15 A (230V input voltage) 02 = 15 A (460V input voltage)
03 = 24 A (230V input voltage) 03 = 30 A 460V input voltage)
05 = 49 A (230V input voltage) 05 = 49 A (460V input voltage)
Module Input Voltage
AM = 230V AC, 50/60 Hz
BM = 460V AC, 50/60 Hz
Bulletin Number
Environmental Specifications
Attribute Operational Range Storage Range (nonoperating)
Temperature, ambient 0…50 ° C (32…122 ° F) -40…70 ° C (-40…158 ° F)
Relative humidity 5…95% noncondensing 5…95% noncondensing
1000 m (3281 ft)
Altitude 3000 m (9843 ft) during transport
3000 m (9843 ft) with derating
5…55 Hz @ 0.35 mm (0.014 in.) double amplitude, continuous displacement; 55…500 Hz @ 2.0 g peak constant
Vibration acceleration (10 sweeps in each of 3 mutually perpendicular directions).
Shock 15 g, 11 ms half-sine pulse (3 pulses in each direction of 3 mutually perpendicular directions)
Weight Specifications
Kinetix 6000 Weight, approx. Kinetix 6000 Weight, approx.
Cat. No. Cat. No.
Module kg (lb) Module kg (lb)
2094-AC05-MP5-S 2.23 (4.9) 2094-BC01-MP5-S 4.98 (11.0)
2094-AC05-M01-S 2.27 (5.0) 2094-BC01-M01-S 5.03 (11.1)
IAM IAM
2094-AC09-M02-S 2.31 (5.1) 2094-BC02-M02-S 5.08 (11.2)
(230V) (460V)
2094-AC16-M03-S 4.71 (10.4) 2094-BC04-M03-S 9.60 (21.1)
2094-AC32-M05-S 7.43 (16.4) 2094-BC07-M05-S 10.1 (22.3)
2094-AMP5-S 1.46 (3.2) 2094-BMP5-S 2.44 (5.4)
2094-AM01-S 1.50 (3.3) 2094-BM01-S 2.49 (5.5)
AM AM
2094-AM02-S 1.54 (3.4) 2094-BM02-S 2.54 (5.6)
(230V) (460V)
2094-AM03-S 3.13 (6.9) 2094-BM03-S 4.58 (10.1)
2094-AM05-S 3.18 (7.0) 2094-BM05-S 4.98 (11.0)
2094-PRS1 1.05 (2.3)
2094-PRS2 1.59 (3.5) Shunt module 2094-BSP2 3.10 (6.8)
2094-PRS3 2.14 (4.7) Slot-filler module 2094-PRF 0.45 (1.0)
While circuit breakers offer some convenience, there are limitations for their use. Circuit breakers do not handle high
current inrush as well as fuses.
Make sure the selected components are properly coordinated and meet acceptable codes including any requirements for
branch circuit protection. Evaluation of the short-circuit available current is critical and must be kept below the
short-circuit current rating of the circuit breaker.
Use class CC, J, L, or R fuses, with current rating as indicated in the table below. The following fuse examples and
Allen-Bradley circuit breakers are recommended for use with 2094-xCxx-Mxx-S IAM modules when the Line Interface
Module (LIM) is not used.
IMPORTANT LIM Modules (catalog numbers 2094-ALxxS, 2094-BLxxS, and 2094-XL75S-Cx) provide branch circuit protection to the
IAM module. Follow all applicable NEC and local codes.
Contactor Ratings
This table lists the recommended contactor ratings for integrated axis modules installed without a line interface module.
IAM Module (230V) IAM Module (460V)
Contactor Contactor
Cat. No. Cat. No.
2094-AC05-MP5-S 100-C23x10 (AC coil) 2094-BC01-MP5-S 100-C23x10 (AC coil)
2094-AC05-M01-S 100-C23Zx10 (DC coil) 2094-BC01-M01-S 100-C23Zx10 (DC coil)
Use this table to size an enclosure and calculate required ventilation for your Kinetix 6000 drive system.
Usage as % of Rated Power Output
Kinetix 6000 Modules (watts)
20% 40% 60% 80% 100%
2094-BC02-M02-S with 4.52 ADC (=20%) converter DC current and 10.3 Arms (=100%) inverter output current.
Converter loss (36 W) + Inverter loss (142 W) = 178 W total power dissipation.
4 CTRL 1 15
(2094-AC05-M01-S front view is shown)
1 2 3 4
DC-
1 2 3
W
DC+
V
6
16
3 L3
U
17
4 5 6
1 2 3 4 5 6 7 8 9
MBRK -
L2
1 2 3 4 5 6
L1
MBRK +
COM
18
PWR 7
CONT EN- DBRK -
1 2
19
1 RX TX BAUD
DPI RATE
8 13 20
9 12
10
11
For connector kit options, refer to Breakout Components and Connector Kits beginning on page 442.
10
2
1 2 3 4
W
V
3
U 11
12
1 2 3 4 5 6 7 8 9
MBRK -
1 2 3 4 5 6
MBRK +
COM
4 13
1 PWR
DBRK -
DBRK +
14
RX TX
BAUD
RATE
5 9 15
6 8
7
For connector kit options, refer to Breakout Components and Connector Kits beginning on page 442.
The Kinetix 2000 multi-axis servo drives are part of the Kinetix Integrated Motion solution.
Topic Page
Kinetix 2000 Servo Drive Components 302
Kinetix 2000 Integrated Axis Modules 306
Kinetix 2000 Axis Modules 308
Kinetix 2000 Power Rail 310
Kinetix 2000 Shunt Module 313
Kinetix 2000 Slot-filler Module 314
Kinetix 2000 General System Specifications 315
Kinetix 2000 Connector, Indicator, and Switch Locations 319
Kinetix 2000 systems may also include any of these optional components:
• One or more integrated axis modules used as a follower IAM (2093-AC05-MPx) and associated axis modules,
power rails, motors, and cables as required for the application
• One shunt module, 2093-ASP06
• Slot-filler modules, 2093-PRF
• Bulletin 2094 Line Interface Module (LIM), 2094-ALxxS, 2094-XL75S-C2, or 2094-AL09
SERCOS interfaceTM
RSLogix 5000
CP OK
Logix Platform
Software
(ControlLogix is shown)
Tx (rear)
Kinetix 2000 Multi-axis Servo Drive System
Rx (front)
I/O Connections
USA
www.ab.co
IN
MADE
075500
X XXXX
LDC-M
NO. XXXX
CAT. L NO.
SERIA
A
SERIES
(1) TL-Series (Bulletin TLY) rotary motors and Bulletin TLAR electric cylinders require the 2090-K2CK-D15M connector kit with 2090-DA-BAT2 battery for multi-turn
high-resolution encoder operation. Other Kinetix 2000 compatible motors and actuators require the connector kit for flying-lead feedback connections, but not the battery.
SERCOS interfaceTM
RSLogix 5000
CP OK
Logix Platform
Software
(ControlLogix is shown)
Three-phase
Input Power Tx (rear)
Rx (front)
Kinetix 2000 Multi-axis Servo Drive System
I/O Connections
2090-K2CK-D15M
LDC-Series Linear Motors Low-profile Connector Kit
(LDC-Cxxxxxxx linear motor shown) (optional component)
2090-K2KSCLAMP-4
Cable Clamp Bracket Kit
(optional component)
m
USA
www.ab.co
IN
MADE
075500
X XXXX
LDC-M
NO. XXXX
CAT. L NO.
SERIA
A
SERIES
(1) TL-Series (Bulletin TLY) rotary motors and Bulletin TLAR electric cylinders require the 2090-K2CK-D15M connector kit with 2090-DA-BAT2 battery for multi-turn
high-resolution encoder operation. Other Kinetix 2000 compatible motors and actuators require the connector kit for flying-lead feedback connections, but not the battery.
In the Kinetix 2000 drive configuration below, the leader IAM is connected to the follower IAM via the DC common bus.
When planning your panel layout, you must calculate the total bus capacitance of your DC common bus system to make
sure that the leader IAM is sized sufficiently to pre-charge the entire system. Refer to the Kinetix 2000 Servo Drive User
Manual, publication 2093-UM001, when making this calculation.
IMPORTANT If total bus capacitance of your system exceeds the leader IAM pre-charge rating, the IAM seven-segment status
indicator will display error code E90 (pre-charge timeout fault) if input power is applied.
To correct this condition, you must remove axis modules from the power rail to decrease the total bus capacitance.
SERCOS interfaceTM
CP OK
Logix Platform RSLogix 5000
(ControlLogix is shown) Software
Tx (rear)
Kinetix 2000 Multi-axis Servo Drive System
Rx (front)
2093-PRF
Power Rail
DC Common Bus 2093-PRSx
Slot-filler Module
(required to fill
any unused slots)
2093-PRF
Power Rail
2093-PRSx
Motors and other details common to both three-phase AC and DC common-bus configurations are removed.
Value
Attribute 2093-AC05-MPx 2093-AC05-MPx
Three-phase Input (230V nom) Single-phase Input (230V nom)
AC input voltage 170…264V rms
AC input frequency 47…63 Hz
167.5
(6.6)
Power 225
Rail (8.8)
Modules are shown mounted to the power rail and the dimensions reflect that in the height and depth of the module.
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your module. For questions regarding product
availability, contact your Allen-Bradley distributor.
2093 - A C 05 - M xx
Inverter Current Rating (peak of sine)
P1 = 1.41 A
P2 = 2.83 A
P5 = 4.24 A
Inverter (Axis Module)
Converter Power Rating
05 = 3 kW (230V three-phase input voltage)
= 2 kW (230V single-phase input voltage)
Converter
Input Voltage
A = 230V AC, 50/60 Hz
Bulletin Number
Bandwidth (1)
Velocity Loop 500 Hz
Current Loop 1300 Hz
PWM frequency 8 kHz
Nominal input voltage 325V DC
Continuous current (rms) 1.0 A 2.0 A 3.0 A 6.0 A 9.5 A
Continuous current (0-pk) 1.41 A 2.83 A 4.24 A 8.48 A 13.4 A
Peak current (rms) 3.0 A 6.0 A 9.0 A 18.0 A 28.5 A
Peak current (0-pk) 4.20 A 8.48 A 12.7 A 25.5 A 40.3 A
Peak output current time (max) 3 s from 0% drive utilization (0% soak)
Continuous power out (nom) 0.3 kW 0.6 kW 0.9 kW 1.9 kW 3.0 kW
Efficiency 98%
Capacitance 200 μF 540 μF
Capacitive energy absorption 7.5 J 20 J
Inverter PCB leakage current 1 mA
(1) Bandwidth values vary based on tuning parameters and mechanical components.
2090-K2KSCLAMP-4 167.5
Cable Clamp Bracket Kit (6.6)
for Motor Power Cable
Modules are shown mounted to the power rail and the dimensions reflect that in the depth of the module.
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your module. For questions regarding product
availability, contact your Allen-Bradley distributor.
2093 - AM xx
Inverter Current Rating (peak of sine)
P1 = 1.41 A
P2 = 2.83 A
P5 = 4.24 A
01 = 8.48 A
02 = 13.4 A
Module Input Voltage
AM = 230V AC, 50/60 Hz
Bulletin Number
The far-left slot on each power rail is the converter slot and used only by the IAM. All other slots are inverter slots and are
used by the IAM, AM, or shunt module (refer to the figure below). The power rail catalog number indicates the maximum
number axes that each power rail will hold.
Power Rail
2093-PRS1
Power Rail
2093-PRS8S
For example, the 2093-PRS1 power rail contains one inverter slot. This limits the use of this power rail to systems requiring
only one inverter slot. Similarly, the 2093-PRS2 power rail contains two inverter slots. This limits the use of this power rail
to systems requiring up to two inverter slots. When selecting a power rail, determine the number of inverter slots required
by all rail-mounted modules and choose a power rail with that minimum number of inverter slots.
IMPORTANT If you select a power rail with slots exceeding the minimum required for your system, you must install a 2093-PRF
slot-filler module in each unused slot.
The 2093-PRS8S power rail is unique in that it accommodates eight axes, but has nine inverter slots. The far-right (ninth)
inverter slot is reserved for a shunt module, but could also be occupied by a slot-filler module or double-wide axis module.
These power rail configurations are supported.
2093-PRS8S Configurations
AM AM AM AM AM AM AM AM AM
AM AM AM AM (double-wide) (double-wide) (double-wide) (double-wide) (double-wide)
AM AM AM AM AM AM AM AM AM
AM AM AM AM AM AM (double-wide) (double-wide) (double-wide)
AM AM AM AM AM AM AM AM
AM
Slot-filler Slot-filler Slot-filler (double-wide) Slot-filler
Shunt module Shunt module Shunt module Shunt module
module module module module
IMPORTANT The maximum number of axes supported by the 2093-PRS8S power rail is eight axes. Do not install an axis module
(AM) in the far-right (ninth) inverter slot.
A 32.6
45 (1.3)
15.1 B
(1.8)
(0.59) C M4 Screw
76
(3.0)
167.5
(6.6)
M4 Screw
Dimensions are in mm (in.)
2093 - PRS x
Module Capacity
1 = IAM and no additional modules
2 = IAM and 1 additional module
3 = IAM and up to 2 additional modules
4 = IAM and up to 3 additional modules
5 = IAM and up to 4 additional modules
7 = IAM and up to 6 additional modules
8S = IAM and up to 8 additional modules
Power Rail
PRS = Power Rail (slim), available in 1, 2, 3, 4, 5, 7, and 8 axis capacity
Bulletin Number
For specifications and dimensions of external shunt resistors compatible with the Kinetix 2000 drive, refer to External Shunt Modules
beginning on page 494.
167.5
(6.6)
Power
Rail
Modules are shown mounted to the power rail and the dimensions reflect that.
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your module. For questions regarding product
availability, contact your Allen-Bradley distributor.
2093 - ASP06
Input Voltage/kW Rating
ASP06 = 230V input voltage, 50 W
Bulletin Number
IMPORTANT The Kinetix 2000 slot-filler module (catalog number 2093-PRF) is compatible with all Kinetix 2000 systems. Power rail
slots not occupied by an IAM, AM, or shunt module, must have a slot-filler module installed.
53 40
(2.1) (1.6)
2093-PRF
Slot-filler Module
167.5
(6.6)
Power
Rail
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your module. For questions regarding product
availability, contact your Allen-Bradley distributor.
2093 - PRF
Power Rail Filler
Bulletin Number
Environmental Specifications
Attribute Operational Range Storage Range (nonoperating)
Temperature, ambient 0…50 ° C (32…122 ° F) -40…85 ° C (-40…185 ° F)
Relative humidity 5…95% noncondensing 5…95% noncondensing
1000 m (3281 ft)
Altitude 3000 m (9843 ft) during transport
3000 m (9843 ft) with derating
5…55 Hz @ 0.35 mm (0.014 in.) double amplitude, continuous displacement; 55…500 Hz @ 2.0 g peak constant
Vibration acceleration (10 sweeps in each of 3 mutually perpendicular directions)
Shock 15 g, 11 ms half-sine pulse (3 pulses in each direction of 3 mutually perpendicular directions)
Weight Specifications
Kinetix 2000 Weight, approx. Kinetix 2000 Weight, approx.
Cat. No. Cat. No.
Module kg (lb) Module kg (lb)
2093-AC05-MP1 2093-PRS1 0.27 (0.6)
IAM 2093-AC05-MP2 1.32 (2.9) 2093-PRS2 0.38 (0.8)
2093-AC05-MP5 2093-PRS3 0.51 (1.1)
Power Rails
2093-AMP1 2093-PRS4 0.64 (1.4)
(Slim)
2093-AMP2 0.67 (1.5) 2093-PRS5 0.77 (1.7)
AM 2093-AMP5 2093-PRS7 1.03 (2.3)
2093-AM01 2093-PRS8S 1.28 (2.8)
0.95 (2.1)
2093-AM02
Shunt module 2093-ASP06 0.59 (1.3) Slot-filler module 2093-PRF 0.15 (0.3)
Although motor feedback cables are available in standard lengths up to 90 m (295.3 ft), the Kinetix 2000 drive maximum
feedback cable length is 30 m (98.4 ft). These tables assume the use of recommended cables as shown in the 2090-Series
Motor/Actuator Cable Selection table on page 402.
Although motor power cables are available in standard lengths up to 90 m (295.3 ft) and the Kinetix 2000 power rail is
available in sizes up to eight axes, to meet CE requirements and improve system performance the combined motor power
length for all axes on the same DC bus must not exceed 160 m (525 ft).
IMPORTANT Operating the Kinetix 2000 drive at maximum temperature with maximum cable length may necessitate derating of
the drive.
While circuit breakers offer some convenience, there are limitations for their use. Circuit breakers do not handle high
current inrush as well as fuses.
Make sure the selected components are properly coordinated and meet acceptable codes including any requirements for
branch circuit protection. Evaluation of the short-circuit available current is critical and must be kept below the
short-circuit current rating of the circuit breaker.
Use class CC, J, L, or R fuses, with current rating as indicated in the table below. The following fuse examples and
Allen-Bradley circuit breakers are recommended for use with the 2093-xCxx-Mxx IAM modules when the Line Interface
Module (LIM) is not used.
IMPORTANT 2094-ALxxS and 2094-XL75S-C2 LIM modules provide branch circuit protection to the IAM module. Follow all
applicable NEC and local codes.
Fuse Specifications
Use this table to size an enclosure and calculate required ventilation for your Kinetix 2000 drive system.
Usage as % of Rated Power Output
Kinetix 2000 Modules (watts)
20% 40% 60% 80% 100%
You can use any general purpose transformer with these ratings.
Attribute Value
Input volt-amperes 500VA
Output voltage 200…240V AC
Contactor Ratings
The table below lists the recommended contactor ratings for integrated axis modules installed without a line interface
module.
11
7 Mounting screw
1 2
17 13
9 SERCOS transmit (Tx) connector
1 2
2
14 10 Seven-segment fault status indicator
1 2 3 4
1 2 3 4 5 6
For motor feedback connector kit catalog numbers, refer to Low-profile Connector Kit Components on page 443. For
replacement connector sets, refer to Connector Sets on page 465.
2093-AMxx AM Connectors
5
4 6
Item Description
1
9 COMM status indicator
10 Bus status indicator
12
11 I/O and auxiliary feedback (IOD/AF) connector
12 Motor feedback (MF) connector
For motor feedback connector kit catalog numbers, refer to Low-profile Connector Kit Components on page 443. For
replacement connector sets, refer to Connector Sets on page 465.
2
6 Bus status indicator
1 2 3
The Kinetix 7000 high power servo drives are part of the Kinetix
Integrated Motion solution.
Topic Page
Kinetix 7000 Servo Drive Components 321
Kinetix 7000 System Component Compatibility Charts 327
Kinetix 7000 High Power Drive Specifications 330
Kinetix 7000 High Power Drive Dimensions 334
Kinetix 7000 Connector, Indicator, and Switch Locations 337
Kinetix 7000 High Power Drive Catalog Numbers 338
Kinetix 7000 systems may also include any of these optional components:
• Bulletin 8720MC Regenerative Power Supply (RPS), 8720MC-RPSxxx (DC common bus operation) with
harmonic filter and varistor
• Bulletin 8720MC-LRxx-xxxx line reactor
• Bulletin 1336-WBxxx brake chopper module
• Bulletin 2094-BL75S (460V) Line Interface Module (LIM)
Typical Configuration - Kinetix 7000 (AC input) System (with LIM module)
Logix Platform
(ControlLogix is shown)
RSLogix 5000
Software
Kinetix 7000 High Power Servo Drive System SERCOS Fiber-optic Ring
2090-SCxxx-x
Three-phase
Input Power
Kinetix 7000 Drive
2099-BM06-S, 2099-BM07-S, or 2099-BM08-S
24V DC
Control Power
Motor Encoder
AC Line Filter Power Feedback
2090-XXLF-TCxxxx Cable Cable
(required for CE)
BRAKE ON
Chopper Module
460 VAC A.F. DRIVES
FOR USE WITH
MADE IN U.S.A.
1 2 3 4 5 6
E11 E12
(1) RDD-Series direct-drive motors require the 2090-K7CK-KENDAT low-profile feedback module for Kinetix 7000 drive applications.
Typical Configuration - Kinetix 7000 (AC input) System (without LIM module)
Logix Platform
RSLogix 5000 (ControlLogix is shown)
Software
Kinetix 7000 High Power Servo Drive System SERCOS Fiber-optic Ring
2090-SCxxx-x
Line
Disconnect
Device
Low Profile Connector Kits for
I/O, Motor Feedback, and Auxiliary Feedback
Input 2090-K6CK-Dxxx
Fusing 24V DC Allen-Bradley
1606-XL
Power Supply
Control Power
1606-XLxxx Input
Motor Encoder
Power Feedback
Cable Cable
AC Line Filter
2090-XXLF-TCxxxx
(required for CE)
BRAKE ON
1 2 3 4 5 6
E11 E12
(1) RDD-Series direct-drive motors require the 2090-K7CK-KENDAT low-profile feedback module for Kinetix 7000 drive applications.
In the figure below, the Kinetix 7000 drive system is shown with the 8720MC Regenerative Power Supply (RPS) in a
regenerative braking configuration. Harmonic filter and varistor are available separately, but are included with the RPS unit
when ordering catalog number 8720MC-RPS065-BM-HV2. In this configuration, the Kinetix 7000 drive provides
motoring power and the RPS unit provides regenerative braking.
Typical Configuration - Kinetix 7000 (AC input) System (with regenerative braking)
AC Line Filter Logix Controller
Input 8720MC-RFI80 Programming Network Logix SERCOS
Fusing (required for CE) interface Module
RSLogix 5000
Software
FAULT
A
V
Common Bus Follower
Kinetix 7000 High Power Servo Drive System
PROGRAM kW
Auxiliary Feedback
2090-K6CK-Dxxx
24V DC
Control Power Allen-Bradley
1606-XL
1606-XLxxx
Po w e r Su p p l y
Input
Control Power
Supply Input
Motor Encoder
Power Feedback
Regenerative Cable Cable
DC Bus
Braking Only
Three-phase
Input Power
Input Magnetic AC Line Filter Line Reactor HPK-Series, RDD-Series, and MP-Series
Fusing Contactor 2090-XXLF-TCxxxx 8720MC-LRxx (Bulletin MPL or MPM) Servo Motors
(required for CE)
IMPORTANT Regenerative braking applications are limited to only one Kinetix 7000 common bus follower drive.
In the figure below, the Kinetix 7000 drive system is shown with the 8720MC Regenerative Power Supply (RPS) in DC
common bus configuration with two follower Kinetix 7000 drives. Harmonic filter and varistor are available separately, but
are included with the when ordering the 8720MC-RPS065-BM-HV2 RPS unit.
In Full-line Regenerative mode the 8720MC-RPS065 unit provides motoring power and regenerative braking.
Typical Configuration - Kinetix 7000 (DC input from RPS unit) System (with full-line regeneration)
AC Line Filter
Logix Controller
Input 8720MC-RFI80
Programming Network Logix SERCOS
Fusing (required for CE)
interface Module
RSLogix 5000
Software
FAULT
A
V
Common Bus Follower Common Bus Follower
PROGRAM kW
24V DC Allen-Bradley
24V DC Allen-Bradley
1606-XLxxx 1606-XLxxx
Input Input
In the figure below, the Kinetix 7000 drive system is shown with the 8720MC Regenerative Power Supply (RPS) in DC
common bus configuration with two follower 2099-BM11-S drives. Harmonic filter, varistor, and magnetic contactor are
included when ordering the 8720MC-EF190-VB EMC line filter.
In Full-line Regenerative mode the 8720MC-RPS190 unit provides motoring power and regenerative braking.
Typical Configuration - Kinetix 7000 (DC input from RPS unit) System (with full-line regeneration)
Three-phase
Input Power
Logix SERCOS
Input interface Module
Fusing
Logix Controller
Programming Network
FAULT
FAUL V
PROGRAM kW
Line Reactor
8720MC-LR10-100B
(two units in parallel)
FAULT V
PROGRAM kW
RST PRG ENT Low Profile Connector Kits for I/O, Motor and
Kits for I/O, Motor and Auxiliary Feedback
8720 MC Auxiliary Feedback
REGENERATIVE POWER SUPPLY
REGENERATIVE POWER SUPPLY 2090-K6CK-Dxxx
2090-K6CK-Dxxx
24V DC 24V DC
Control Power
Allen-Bradley
1606-XL
Power Supply
Control Power Allen-Bradley
1606-XL
Power Supply
1606-XLxxx 1606-XLxxx
Input Input
8720MC-LR10-100B HPK-E1613E
8720MC-RPS190BM
(two units) HPK-E2010C
(1) Regenerative Power Supply (RPS) selection is for this single motor/drive combination. When combining multiple drives on the same
RPS module, the selection will change.
2099-BM06-S RDB-B2152C
2099-BM06-S RDB-B2153C
2099-BM07-S RDB-B29029
2099-BM06-S RDB-B29036
2099-BM08-S RDB-B29039
8720MC-RPS065BM 8720MC-LR05-048B
2099-BM06-S RDB-B41016
2099-BM08-S RDB-B41018
2099-BM06-S RDB-B41024
2099-BM09-S RDB-B41026
2099-BM09-S RDB-B41035
(1) Regenerative Power Supply (RPS) selection is for this single motor/drive combination. When combining multiple drives on the same
RPS module, the selection will change.
Power Specifications
Attribute 2099-BM06-S 2099-BM07-S 2099-BM08-S 2099-BM09-S 2099-BM10-S 2099-BM11-S 2099-BM12-S
Total capacitance (3) 1800 μF 2400 μF 3000 μF 4500 μF 6000 μF 8400 μF 8400 μF
Short circuit current rating 200,000 A (rms) symmetrical
(1) Bandwidth values vary based on tuning parameters and mechanical components.
(2) Bus undervoltage will vary based on input line voltage.
(3) If DC input is supplied to 2099-BM09-S, 2099-BM10-S, or 2099-BM11-S drives, the precharge capability must be provided at the system level. Disconnect switches must
not be used between the input of the drive and a common DC bus without the use of an external precharge device.
Environmental Specifications
Attribute Operational Range Storage Range (nonoperating)
Temperature, ambient 0…50 ° C (32…122 ° F) -40…70 ° C (-40…158 ° F)
Relative humidity 5…95% noncondensing 5…95% noncondensing
1000 m (3281 ft)
Altitude 3000 m (9843 ft) during transport
3000 m (9843 ft) with derating
5…55 Hz @ 0.35 mm (0.014 in.) double amplitude, continuous displacement; 55…500 Hz @ 2.0 g peak constant
Vibration acceleration (10 sweeps in each of 3 mutually perpendicular directions).
Shock 15 g, 11 ms half-sine pulse (3 pulses in each direction of 3 mutually perpendicular directions)
Weight Specifications
Weight, approx.
Drive Cat. No.
kg (lb)
2099-BM06-S
2099-BM07-S 18.55 (40.9)
2099-BM08-S
2099-BM09-S
37.2 (82.0)
2099-BM10-S
2099-BM11-S
71.4 (157.5)
2099-BM12-S
Use this table to size an enclosure and calculate required ventilation for your Kinetix 7000 drive system.
Usage as % of Rated Power Output
Drive Cat. No. W
50% 100%
2099-BM06-S 294 465
2099-BM07-S 388 619
2099-BM08-S 452 730
2099-BM09-S 645 1072
2099-BM10-S 882 1479
2099-BM11-S 1275 2125
2099-BM12-S 1438 2437
While circuit breakers offer some convenience, there are limitations for their use. Circuit breakers do not handle high
current inrush as well as fuses.
Make sure the selected components are properly coordinated and meet acceptable codes including any requirements for
branch circuit protection. Evaluation of the short-circuit available current is critical and must be kept below the
short-circuit current rating of the circuit breaker.
Use class CC, T, RK1, or J fuses, with current rating as indicated in the table below. The following fuse examples and
short-circuit current ratings are recommended for use with the 2099-BMxx-S drives when the Line Interface Module
(LIM) is not used.
IMPORTANT LIM modules (catalog numbers 2094-BLxxS and 2094-XL75S-Cx) provide branch circuit protection to the Kinetix 7000
drive. Follow all applicable NEC and local codes.
Fuse Specifications
Contactor Ratings
The table below lists the recommended contactor ratings for Kinetix 7000 drives installed without a Line Interface
Module.
Drive Cat. No. Contactor Safety Contactor Coil Type Coil Voltage Requirements
2099-BM06-S 100-C43DJ01 100S-C43-DJD4C Standard with Diode 24V DC
2099-BM07-S
2099-BM08-S 100-D95EN11 100S-D95EN22C
2099-BM09-S
Electronic Coil (1) 24V DC for control and 480V AC for coil power
2099-BM10-S 100-D140EN11 100S-D140EN22C
2099-BM11-S 100-D180EN11 100S-D180EN22C
2099-BM12-S 100-D250EN11 100S-D250EN22C
(1) Electronic coil control power requirements = 24V DC @ 15 mA.
Although motor power and feedback cables are available in standard lengths up to 90 m (295.3 ft), the
drive/motor/feedback combination may limit the maximum feedback cable length. This table assumes the use of
recommended cables as shown in the 2090-Series Motor/Actuator Cable Selection table on page 402.
517.5
(20.37)
495.0
(19.49)
Ø 22.4 Ø 47.0
(0.88) Ø 37.3 (1.85) 2X
Ø 28.7 (1.47) X2 Ø 28.7
(1.13) (1.13)
7.0
(0.28)
644.5
(25.37)
644.5 2099-BM09
(25.37)
625.0
(24.61)
690.3
(27.18)
2099-BM10
12.0 6.5
(0.47) (0.26) 2X
259.1 20.4
(10.20) 2X (0.80) 2X
31.9 300.0
(1.26) (11.81)
60.4 70
(2.38) (2.75) 35
(1.38)
24.5
159.5 (0.96) 2X
153.5
(6.28) (6.04) 2X
7.9
(0.31)
849.97
(33.46)
850.0
(33.46)
824.0
(32.44)
977.1
(38.47)
14.5
(0.04)
8.5
(0.33) 2X
360.6
(14.20) 2X
30.0 399.2
(1.18) (15.72)
73.8 67.2
(2.90) 36.9 (1.45) 4X (2.64)
148.4 151.7
(5.84) (5.97)
45.0
31.69 (1.25)
(1.77)
22.0 (0.86) 2X
128 100
(5.04) (3.94)
150 (5.90) 2X
200 (7.87)
For connector kit options, refer to Breakout Components and Connector Kits beginning on page 442.
R (L1)
S (L2)
T (L3)
DC+
DC-
NC
NC
W
U
V
Cable Shield Clamps for PE
Motor and AC Inputs
R (L1)
S (L2)
T (L3)
120V AC
240V AC
DC+
PS+
DC-
PS-
PE
W
0V AC
PE
U
V
240V AC
PS+ DC+ DC-
Power Terminal Block
PS- 120V AC 2099-BM10-S
0V AC
Reserved for
DC Bus Motor Power Fan Pwr AC Line
Motor Power AC Line Factory Use
120V AC
240V AC
U V W PE PE R S T
0V AC
R (L1)
S (L2)
T (L3)
T1 T2 T3 L1 L2 L3
DC+
PS+
DC-
PS-
PE
W
PE
OUTPUT INPUT
U
Topic Page
Kinetix 300 Servo Drive Components 339
Kinetix 300 Drive Power Specifications 341
Kinetix 300 Drive Accessory Specifications 343
Kinetix 300 General System Specifications 347
Kinetix 300 Connector and Indicator Locations 352
Kinetix 300 Drive Catalog Numbers 352
Kinetix 300 servo drive systems may also include any of these optional components:
• One 2097-Fx or Bulletin 2090 AC line filter
• One 2097-Rx shunt resistor
2097-Rx
Shunt Resistor
2097-V3xxxx Bulletin 2090 or 2097-Fx (optional equipment)
Kinetix 300 Drive AC Line Filter (optional equipment)
00
300
2097-F1 Filter Shown
24V DC Control
Back-up Power Supply
2097-TB1 Terminal
(optional equipment)
Expansion Block
Bulletin 2090
Bulletin 2090 Motor Power Cables
Motor Feedback Cables
MP-Series and TL-Series (1) Electric Cylinders
(MPAR-Bxxxx electric cylinders shown)
MP-Series and TL-Series (1) (2)
Rotary Motors MP-Series Heavy Duty Electric Cylinders
(MPL-Bxxxx motors shown) (MPAI-Bxxxx electric cylinders shown)
(1) TL-Series (Bulletin TLY) rotary motors and Bulletin TLAR electric cylinders require the 2090-K2CK-D15M connector kit with 2090-DA-BAT2 battery for multi-turn
high-resolution encoder operation. Other Kinetix 300 compatible motors and actuators require the connector kit for flying-lead feedback connections, but not the battery.
(2) Maximum speed for rotary motors paired with Kinetix 300 drives is 5000 rpm.
(3) Kinetix 300 drives are compatible with only Bulletin MPAS (ballscrew) linear stages.
Peak output current (rms) (2) 6.0 A 12.0 A 6.0 A 12.0 A 24.0 A
Peak output current (0-pk) 8.5 A 17.0 A 8.5 A 17.0 A 33.9 A
(1) Add this value to the dimensions of your Kinetix 300 drive.
Attribute Value
+ 6V DC, min 150 mA supply
Internal batteries
4 mono-cells (type D), 1.5V DC each
DC supply 105
External power (4.1)
+ 6V DC, 300 mA, stabilized
supply unit
Type LCD
Display format Text
Display
Lines x characters 1 x 16 155
(6.1)
Contrast setting Via menu
Up to 120 parameter files for
Memory Data memory inverter drive controllers 2097-PGMR
Memory Module Programmer 76
Serial interface DB9 connector RS-232 (3.0)
Weight 2097-PGMR 1.3 kg (2.87 lb), with batteries
AC Line Filters
The Kinetix 300 drives were tested by using recommended line filters. Use of these filters is also needed to meet CE
requirements. The 2097-V32PR0, 2097-V32PR2, and 2097-V32PR4 drives have integrated AC line filters.
Kinetix 300
Drive
00
300
2097-F1 or 2097-F2
150 Side Mount
(5.90) AC Line Filters
Kinetix 300
Drive
This connector ships
prewired to the AC line filter.
48.0
(1.89)
(1) Use 2090-XXLF-TC116 (single-phase) line filter for 2097-V31PR0 and 2097-V31PR2 drives. Use 2090-UXLF-336 line filter for 2097-V33PR5 (three-phase) drive applications.
Refer to AC Line Filter Specifications on page 486 for more information.
(2) Use the 2097-F1 (single-phase) line filter only for 2097-V33PR6 (single-phase) drive operation.
(3) This filter is rated for multiple voltage/phase line conditions.
The Bulletin 2097 passive shunt resistor wires directly to the Kinetix 300 drive.
12.0
(0.47 10.0
(0.39
4.3
(0.17)
Shunt Resistor L1 L2 L3
Cat. No.
2097-R2 210 (8.3) 197 (7.7) 170 (6.7)
2097-R3 210 (8.3) 197 (7.7) 170 (6.7)
L2
L1 L3 2097-R4 150 (5.9) 137 (5.4) 110 (4.3)
2097-R6 210 (8.3) 197 (7.7) 170 (6.7)
2097-R7 150 (5.9) 137 (5.4) 110 (4.3)
10.0
(0.39 12.0 41.0
(0.47 (1.6)
Environmental Specifications
Attribute Operational Range Storage Range (nonoperating)
Temperature, ambient 0…40 ° C (32…104 ° F) -10…70 ° C (14…158 ° F)
Relative humidity 5…95% noncondensing 5…95% noncondensing
Altitude Derate by 1% per 300 m (1000 ft) above 1500 m (5000 ft) 3000 m (9842 ft) during transport
Vibration 5…2000 Hz @ 2.5 g peak, 0.015 mm (0.0006 in.) maximum displacement
Shock 15 g, 11 ms half-sine pulse (3 pulses in each direction of 3 mutually perpendicular directions)
Weight Specifications
Weight, approx. Weight, approx.
Drive Cat. No. Drive Cat. No.
kg (lb) kg (lb)
2097-V31PRO 1.3 (2.9) 2097-V33PR3 1.5 (3.3)
2097-V31PR2 1.5 (3.3) 2097-V33PR5 2.0 (4.4)
2097-V32PRO 1.4 (3.1) 2097-V33PR6 1.9 (4.2)
2097-V32PR2 1.7 (3.7) 2097-V34PR3 1.5 (3.3)
2097-V32PR4 2.2 (4.9) 2097-V34PR5 2.0 (4.4)
2097-V33PR1 1.3 (2.9) 2097-V34PR6 1.8 (4.0)
Use this table to size an enclosure and calculate required ventilation for your Kinetix 300 drive system.
Loss, Max Loss, Max
Drive Cat. No. Drive Cat. No.
W W
2097-V31PRO 28 2097-V33PR3 39
2097-V31PR2 39 2097-V33PR5 67
2097-V32PRO 28 2097-V33PR6 117
2097-V32PR2 39 2097-V34PR3 39
2097-V32PR4 67 2097-V34PR5 58
2097-V33PR1 28 2097-V34PR6 99
While circuit breakers offer some convenience, there are limitations for their use. Circuit breakers do not handle high
current inrush as well as fuses.
Make sure the selected components are properly coordinated and meet acceptable codes including any requirements for
branch circuit protection. Evaluation of the short-circuit available current is critical and must be kept below the
short-circuit current rating of the circuit breaker.
Use class CC or T fast-acting current-limiting type fuses, 200,000 AIC, preferred. Use Bussman KTK-R, JJN, JJS, or
equivalent. Thermal-magnetic type breakers preferred. The following fuse examples and Allen-Bradley circuit breakers are
recommended for use with Kinetix 300 drives.
Main VAC
Contactor Ratings
These table list the recommended contactor ratings for Kinetix 300 drives.
Although motor power and feedback cables are available in standard lengths up to 90 m (295.3 ft), Kinetix 300 drive
maximum feedback cable length is 20 m (65.6 ft). These tables assume the use of recommended cables as shown in the
2090-Series Motor/Actuator Cable Selection table on page 402.
A 30.8
(1.21)
Dimensions are in mm (in.). 5.0 7.1
(0.19) (0.28)
182
(7.18)
190
238 (7.50)
(9.37) 2097-TB1
I/O Terminal
Expansion Block
6.6
(0.26)
2090-K2CK-D15M Ø 4.57
11.8 (0.18) 3x
Low-profile Connector Kit for 61.0 (0.46) 38.1
Bulletin 2090 (flying-lead) (2.40) (1.5)
Feedback Cable B
3 10
00
300 11
9
5
12
1
8
7
Kinetix 300 Drive, Top View Kinetix 300 Drive, Front View Kinetix 300 Drive, Bottom View
(2097-V33PR5 drive is shown) (2097-V33PR5 drive is shown) (2097-V33PR5 drive is shown)
(1) The MF (15-pin) connector requires the 2090-K2CK-D15M low-profile connector kit.
For connector kit options, refer to Breakout Components and Connector Kits beginning on page 442.
Topic Page
Kinetix 3 Servo Drive Components 353
Kinetix 3 Drive Power Specifications 355
Kinetix 3 Drive Accessory Specifications 356
Kinetix 3 General System Specifications 357
Kinetix 3 Servo Drive Dimensions 359
Kinetix 3 Connector and Indicator Locations 360
Kinetix 3 Servo Drive Catalog Numbers 360
Kinetix 3 servo drive systems may also include any of these optional components:
• One 2071-TBMF breakout board for motor feedback
• One 2071-TBIO breakout board for control interface
• 2090 control and configuration serial cables
Disconnect 2071-Axxxx
Device Kinetix 3 Servo Drive OK
2090-CCMPCDS-23AAxx
Programming Cable (programming only)
2090-CCMCNDS-48AAxx
Line Fusing Controller Cable
2090-XXLF-TCxxx
AC Line Filter 2071-TBIO I/O
(optional equipment) Breakout Board
(optional equipment)
USA
www.ab.co
(LDC-Cxxxxxxx linear motor shown)
075500
X XXXX
LDC-M
NO. XXXX
CAT. L NO.
SERIA
A
SERIES
(1) TL-Series (Bulletin TLY) rotary motors and Bulletin TLAR electric cylinders require the 2071-TBMF breakout board with 3.6V lithium battery (not included) for multi-turn
high-resolution encoder operation. Other Kinetix 3 compatible motors and actuators require the breakout board for flying-lead feedback connections, but not the battery.
2071-Axxxx
Kinetix 3 Servo Drive
1766-L32xxx ESC
2090-CCMCNDS-48AAxx
Controller Cable
2090-DANFCT-Sxx
Motor Feedback Cable 2071-Axxxx
Kinetix 3 Servo Drives
2071-Axxxx
Kinetix 3 Servo Drive
2090-DANPT-16Sxx
Motor Power Cable
2090-CCMDSDS-48AAxx
Drive-to-Drive Cable
(1) TL-Series (Bulletin TL) rotary motors require the 2071-TBMF breakout board with 3.6V lithium battery (not included) for multi-turn high-resolution encoder operation or
when using an overtravel limit switch. To meet this requirement, remove the drive-end connector and wire the 2090-DANFCT-Sxx cable to the 2071-TBMF breakout board.
Bandwidth (2)
Velocity loop 550 Hz
Current loop 2000 Hz
PWM frequency 10 kHz
Control power AC input voltage 170…264V rms
Control power input current
Nom (rms) 0.1 A rms
Max inrush (0-pk) 31 A
Continuous output current (rms) 0.61 A 1.11 A 1.72 A 3.33 A 5.05 A 7.07 A 9.90 A
Continuous output current (0-pk) 0.85 A 1.56 A 2.40 A 4.67 A 7.07 A 9.90 A 13.99 A
Peak output current (rms) 1.80 A 3.30 A 5.10 A 9.90 A 14.99 A 18.88 A 29.69 A
Peak output current (0-pk) 2.55 A 4.67 A 7.21 A 14.0 A 21.21 A 26.70 A 41.99 A
Continuous output power 50 W 100 W 200 W 400 W 800 W 1.0 kW 1.5 kW
Bus overvoltage 405V DC
Bus undervoltage 190V DC
Internal shunt resistor N/A 50 Ω 30 Ω
Internal shunt
Continuous power N/A 30 W 70 W
Peak power N/A 300 W 700 W
Shunt on 390V DC
Shunt off 380V DC
Efficiency 90%
Bus capacitance 390 μF 780 μF 1170 μF
Capacitive energy absorption 13 J 26 J 39 J
Short circuit current rating 100,000 A (rms) symmetrical
(1) Kinetix 3 drive modules are limited to 1 AC mains power cycling every 2 minutes.
(2) Bandwidth values vary based on tuning parameters and mechanical components.
(1) Add this value to the dimensions of your Kinetix 3 drive. Refer to Kinetix 3 18.0 48.0
Servo Drive Dimensions on page 359. (0.71) (1.89)
Environmental Specifications
Attribute Operational Range Storage Range (nonoperating)
Temperature, ambient 0…50 ° C (32…122 ° F) -25…85 ° C (-13…185 ° F)
Relative humidity 5…95% noncondensing 5…95% noncondensing
1000 m (3281 ft)
Altitude 3000 m (9843 ft) during transport
3000 m (9843) with derating
5…55 Hz @ 0.35 mm (0.014 in.) double amplitude, continuous displacement; 55…500 Hz @
Vibration 2.0 g peak constant acceleration (10 sweeps in each of 3 mutually perpendicular directions).
Shock 15 g, 11 ms half-sine pulse (3 pulses in each direction of 3 mutually perpendicular directions)
Weight Specifications
Weight, approx.
Drive Cat. No.
kg (lb)
2071-AP0 0.70 (1.5)
2071-AP1
0.75 (1.6)
2071-AP2
2071-AP4 1.0 (2.2)
2071-AP8
2071-A10 1.75 (3.9)
2071-A15
Use this table to size an enclosure and calculate required ventilation for your Kinetix 3 drive system.
Usage as % of Rated Power Output
Drive Cat. No. (watts)
20% 40% 60% 80% 100%
2071-AP0 19.3 20.0 20.6 21.3 22.0
2071-AP1 20.1 21.6 23.1 24.6 26.2
2071-AP2 21.7 24.6 27.6 30.6 33.7
2071-AP4 25.6 31.9 38.4 45.2 52.2
2071-AP8 26.4 32.3 38.6 45.1 52.0
2071-A10 30.9 40.2 50.1 60.5 71.5
2071-A15 37.4 50.1 63.8 78.4 93.9
Fuse/Contactor Specifications
Make sure the selected components are properly coordinated and meet acceptable codes including any requirements for
branch circuit protection. The following fuse examples are recommended for use with Kinetix 3 drives.
FNQ-R-30
2071- A15 100-C23xy
LPJ-30
(1) Fuses specified are Bussmann fuses.
(2) FNQ-R fuses are described as time-delay fuses, Class CC.
(3) LPJ fuses are described as dual-element time-delay fuses, Class J.
(4) FRS-R fuses are described as dual-element time-delay fuses, Class RK5.
(5) For contactors: x represents coil voltage, y represents the number of contacts.
Although motor power and feedback cables are available in standard lengths up to 90 m (295.3 ft), Kinetix 3 drive
maximum feedback cable length is 30 m (98.4 ft). These tables assume the use of recommended Bulletin 2090 cables as
shown in the 2090-Series Motor/Actuator Cable Selection table on page 402.
Incremental/TTL
Linear Motor Cat. No. (5V) Encoder
m (ft)
LDC-Series or LDL-Series 30 (98.4)
29.0
(1.14)
145
(5.70) 155
(6.11)
A B C D
Drive Cat. No. mm (in.) mm (in.) mm (in.) mm (in.)
2071-AP0
53.0
2071-AP1
153 141 48.3 (2.09)
2071-AP2 (6.04) (5.55) (1.90)
58.0
2071-AP4
(2.29)
2071-AP8
198 186 59.0 81.0
2071-A10
(7.82) (7.33) (2.32) (3.19)
2071-A15
Item Description
15
1 Left/right and up/down keys
14 2 Analog output (A.out)
1
13 3 RS-485 communication termination switch
9
13 Enter key
7
14 Mode/set key
8 15 7-segment status indicator
For connector kit options, refer to Kinetix 3 Drive Accessory Specifications on page 356.
2071 - A xx
The Kinetix 3 drives are configured by using Ultraware software (catalog number 2098-UWCPRG), version 1.80 or later.
Topic Page
Ultra3000 Servo Drive Communication Interface 361
Ultra3000 Digital Servo Drive Components 362
Ultra3000 Digital Servo Drive Specifications 364
Ultra3000 Digital Servo Drive Dimensions 371
Ultra3000 Connector, Indicator, and Switch Locations 374
Ultra3000 Digital Servo Drive Catalog Numbers 377
Logix Platform
(ControlLogix is shown)
RSLogix 5000
Software
Ultra3000-SE Ultra3000-SE
Servo Drive Servo Drive
Motor
SERCOS Fiber-optic Ring Feedback
USA
www.ab.co
IN
MADE
075500
X XXXX
LDC-M
NO. XXXX
CAT. L NO.
(1) Ultra3000 drives are compatible with only TL-Series (Bulletin TLY-Axxxx-H) motors with incremental encoders.
(1) Ultra3000 drives are compatible with only TL-Series (Bulletin TLY-Axxxx-H) motors with incremental encoders.
(1) Ultra3000 drives are compatible with only TL-Series (Bulletin TLY-Axxxx-H) motors with incremental encoders.
Power Specifications
2098-DSD-005x-xx, 2098-DSD-010x-xx, and 2098-DSD-020x-xx Ultra3000 (230V) Drives
Attribute 2098-DSD-005 2098-DSD-010 2098-DSD-020
(1) Specification is for nominal voltage. The absolute limits are ±10%, or 88…265V rms.
(2) The 2098-DSD-030x-xx, 2098-DSD-075x-xx, and 2098-DSD-150x-xx (230V) drives are limited to one contactor cycles per two minutes.
(3) Power initialization requires a short period of inrush current. Dual element time delay (slow blow) fuses are recommended (refer to Fuse Specifications on page 367).
(4) 400 μs half wave sine.
(1) Specification is for nominal voltage. The absolute limits are ±10%, or 207…264V rms and 324…528V rms.
(2) The 2098-DSD-HVxxx-xx drives can be powered with 230V rms and used with motors designed for 230V operation. In such cases, the voltage levels used for shunting and
DC bus overvoltage limits are adjusted to be compatible with the voltage limit of the motor.
The 2098-DSD-HVxxx-xx drives can be powered with 480V rms and used with motors designed for 480V operation. In such cases, the voltage levels used for shunting and
DC bus overvoltage limits are adjusted to be compatible with the voltage limit of the motor.
(3) The 2098-DSD-HVxxx -xx (460V) drives are limited to three contactor cycles per minute.
(4) Power initialization requires a short period of inrush current (processor controlled via soft start circuitry). Dual element time delay (slow blow) fuses are recommended
(refer to Fuse Specifications on page 367).
(5) 400 μs half wave sine.
Fuse Specifications
Use class CC, G, J, L, R, or T fuses, with current ratings as indicated in the table below. The table below lists fuse examples
recommended for use with the Ultra3000 (230V and 460V) drives.
While circuit breakers offer some convenience, there are limitations for their use. Circuit breakers do not handle high
current inrush as well as fuses.
Make sure the selected components are properly coordinated and meet acceptable codes including any requirements for
branch circuit protection. Evaluation of the short-circuit available current is critical and must be kept below the
short-circuit current rating of the circuit breaker.
Contactor Ratings
Input
Drive Cat. No. Contactor
Voltage
100-C23x10 (AC coil)
2098-DSD-HV030 100-C23Zx10 (DC coil)
100-C30x10 (AC coil)
2098-DSD-HV050 100-C30Zx10 (DC coil)
100-C37x10 (AC coil)
2098-DSD-HV100 460V 100-C37Zx10 (DC coil)
100-C43x10 (AC coil)
2098-DSD-HV150 100-C43Zx10 (DC coil)
100-C60x10 (AC coil)
2098-DSD-HV220 100-C60Zx10 (DC coil)
Communication Specifications
Attribute Value
SERCOS (option)
Communication rates 4 and 8 Mbps
Node addresses 01…99
DeviceNet (option)
Power consumption from 60 mA
network
Data rates 125, 250, and 500 kps, and auto-baud
Node addresses 00…63
Messaging capabilities Explicit, Polled I/O, Change of State, and Cyclic Messaging
Serial
Ports One RS-232/RS-422/RS-485
Communication rates 1200, 2400, 4800, 9600, 19,200, and 38,400 bps
Inputs/Outputs Specifications
Attribute Value
Digital inputs 8 optically isolated, 12…24V, active high, current sinking
Digital outputs 4 optically isolated, 12…24V, active high, current sourcing
Relay output One normally open relay, 30V DC, max, 1 A, max
I/O response 100 µs
Digital I/O firmware scan period 1 ms
Analog inputs
COMMAND 14-bit A/D, ±10V
ILIMIT 10-bit A/D, 0 to 10V
Analog output ±10V, 8 bits, 2 mA max
Connector Specifications
Connector Description Specification
CN1 User input/output 44-pin high-density female D-sub connector
CN2 Motor feedback connector 15-pin high-density female D-sub connector
CN3 Serial port connector 9-pin female D-sub connector
Main and auxiliary AC, DC bus, motor power,
TB1 and TB2 Screw terminal block
and shunt connectors
Although motor feedback cables are available in standard lengths up to 90 m (295.3 ft), the drive/motor/feedback
combination may limit the maximum cable length, as shown in the tables below. These tables assume the use of cables
recommended in 2090-Series Motor/Actuator Cable Selection table on page 402.
In the figure below, -xxx is replaced by -005, -010, or -020 to represent the Ultra3000 500 W, 1 kW, and
2 kW drives respectively.
A 129.03
38.1 C (5.08)
(1.5)
E 144.27
(5.68)
F
A C E F
Ultra3000 Drives
mm (in.) mm (in.) mm (in.) mm (in.)
2098-DSD-005, 72.64
2098-DSD-005X (2.86)
2098-DSD-010, 65.02 13.26 32.77
2098-DSD-010X, (2.56) (0.52) (1.29) 98.1
2098-DSD-020, (3.89)
2098-DSD-020X
2098-DSD-005-SE, 95.5
2098-DSD-005-DN, (3.76)
2098-DSD-005X-DN
2098-DSD-010-SE, 87.88 24.64 43.94
2098-DSD-010-DN, (3.46) (0.97) (1.73)
2098-DSD-010X-DN, 121.54
2098-DSD-020-SE, (4.79)
2098-DSD-020-DN,
2098-DSD-020X-DN
In the figure below, -xxx is replaced by -030, -075, or -150 to represent the Ultra3000 3, 7.5, and
15 kW drives respectively.
A
B 227.08
C (8.94)
C
B J
A B C J
Ultra3000 Drives
mm (in.) mm (in.) mm (in.) mm (in.)
2098-DSD-030,
2098-DSD-030X, 91.44 50.8 20.32 243.84
2098-DSD-030-SE, (3.6) (2.0) (0.8) (9.6)
2098-DSD-030-DN,
2098-DSD-030X-DN
2098-DSD-075,
2098-DSD-075X, 138.68 88.9 24.89 247.14
2098-DSD-075-SE, (5.41) (3.5) (0.96) (9.73)
2098-DSD-075-DN,
2098-DSD-075X-DN
2098-DSD-150,
2098-DSD-150X, 188.97 139.7 24.6 241.05
2098-DSD-150-SE, (7.44) (5.5) (0.97) (9.49)
2098-DSD-150-DN,
2098-DSD-150X-DN
In the figure below, xxx is replaced by 030, 050, 100, 150, or 220 to represent the Ultra3000 3, 5, 10, 15, and 22 kW drives
respectively.
A
225.8
B B C (8.89)
B B C 242.2
(9.54)
A C B D H I
Ultra3000 Drives (1) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
2098-DSD-HV030x,
2098-DSD-HV030-xx, 138.7 18.5
2098-DSD-HV050x, 5.46) (0.73)
2098-DSD-HV050-xx 50.8 349.3 331.5 360.7
2098-DSD-HV100x, (2.0) (13.75) (13.05) (14.2)
2098-DSD-HV100-xx, 151.6 25
2098-DSD-HV150x, (5.97) (0.99)
2098-DSD-HV150-xx
2098-DSD-HV220x, 203.2 25.4 76.2 380.4 362.6 391.8
2098-DSD-HV220-xx (8.0) (1.0) (3.0) (14.98) 14.26) (15.43)
(1) The x represents the indexing (X) option. The -xx represents the SERCOS interface (SE) or DeviceNet interface (DN) option. SERCOS interface is
not available with the DeviceNet interface option.
5
9
4
6 10
11
3
7
2 12
8 13
1 15
14
For CN1, CN2, and CN3 connector options, refer to Breakout Components and Connector Kits beginning on page 442.
5
1
Internal
4 External
2 6
Shunt
3
10
TB2 11
12
13
7
U
V
Motor
3 W
8
+
DC Bus
2 -
L1
L2
L3
9
1 100-240 VAC
50/60 Hz
L1
AUX
L2/N DeviceNet
AUX
14 V-
TB1 Can_L
15 16 Shield
Can_H
V+
For CN1, CN2, and CN3 connector options, refer to Breakout Components and Connector Kits beginning on page 442.
6
10
11
(00-63, PGM)
12
1
Internal
External Shunt
125kB
4 2
13 250kB
500kB
AUTO
3 PGM
TB2
7
DANGER
Hazardous voltage
exists after power down.
+
DC Bus
3 -
8
W
V
Motor
2 U
9
L3
L2
230-480 VAC
50/60 Hz
1 L1 DeviceNet
L1
AUX 14 V-
Can_L
L2
AUX
16
Shield
15 Can_H
V+
TB1
For CN1, CN2, and CN3 connector options, refer to Breakout Components and Connector Kits beginning on page 442.
Ultra3000, Ultra3000 with indexing, Ultra3000-DN, and Ultra3000-DN with indexing drives are configured by using
Ultraware software (catalog number 2098-UWCPRG). The Ultra3000-SE drives are configured by using RSLogix 5000
software.
Notes:
Topic Page
Ultra5000 Servo Drive Communication Interface 379
Ultra5000 Intelligent Positioning Drive Components 380
Ultra5000 Intelligent Positioning Drive Specifications 381
Ultra5000 Intelligent Positioning Drive Dimensions 388
Ultra5000 Connector, Indicator, and Switch Locations 391
Ultra5000 Intelligent Positioning Drives Catalog Numbers 394
Ultra5000 systems may also include a Bulletin 2090 external active or passive shunt module.
To learn about the C programming environment or library of motion commands used to program an Ultra5000 intelligent
positioning drive, refer to the Ultra5000 Programming Manual, publication 2098-PM001.
Motor Feedback
Motor Power
MP-Series (1) and TL-Series (2) Rotary Motors
(MPL-xxxx motors shown)
(1) MPL-B15xx and MPL-B2xx motors are not compatible with Ultra5000 drives.
(2) Ultra5000 drives are compatible with only TL-Series (Bulletin TLY-Axxxx-H) motors with incremental encoders.
Motor Feedback
Motor Power
MP-Series (1) and TL-Series (2) Rotary Motors Ultraware
(MPL-xxxx motors shown) Software
(1) MPL-B15xx and MPL-B2xx motors are not compatible with Ultra5000 drives.
(2) Ultra5000 drives are compatible with only TL-Series (Bulletin TLY-Axxxx-H) motors with incremental encoders.
Power Specifications
2098-IPD-005-xx, 2098-IPD-010-xx, and 2098-IPD-020-xx Ultra5000 (230V) Drives
(1) Specification is for nominal voltage. The absolute limits are ±10%, or 88…265V rms.
(2) The 2098-IPD-030x-xx, 2098-IPD-075x-xx, and 2098-IPD-150x-xx (230V) drives are limited to one contactor cycles per two minutes.
(3) Power initialization requires a short period of inrush current. Dual element time delay (slow blow) fuses are recommended (refer to Fuse Specifications on page 384).
(4) 400 μs half wave sine.
(1) Specification is for nominal voltage. The absolute limits are ±10%, or 207…264V rms and 324…528V rms.
(2) The 2098-IPD-HVxxx-xx drives can be powered with 230V rms and used with motors designed for 230V operation. In such cases, the voltage levels used for shunting and
DC bus overvoltage limits are adjusted to be compatible with the voltage limit of the motor.
The 2098-IPD-HVxxx-xx drives can be powered with 480V rms and used with motors designed for 480V operation. In such cases, the voltage levels used for shunting and
DC bus overvoltage limits are adjusted to be compatible with the voltage limit of the motor.
(3) The 2098-IPD-HVxxx -xx (460V) drives are limited to three contactor cycles per minute.
(4) Power initialization requires a short period of inrush current (processor controlled via soft start circuitry). Dual element time delay (slow blow) fuses are recommended
(refer to Fuse Specifications on page 384).
(5) 400 μs half wave sine.
Fuse Specifications
Use class CC, G, J, L, R, or T class fuses, with current ratings as indicated in the table below. The table below lists fuse
examples recommended for use with the Ultra3000 (230V and 460V) drives.
Recommended Fuse
Input
Drive Cat. No. Input Type
Voltage
Class CC (1) Class J (1)
2098-IPD-005 FNQ-R-6 LPJ-6SP
2098-IPD-010 FNQ-R-10 LPJ-10SP
2098-IPD-020 FNQ-R-20 LPJ-20SP
Input power
2098-IPD-030 230V AC FNQ-R-30 LPJ-30SP
2098-IPD-075 FNQ-R-30 LPJ-30SP
2098-IPD-150 N/A LPJ-60SP
2098-IPD-xxx Auxiliary input power FNQ-R-10 LPJ-10SP
2098-IPD-HV030 KTK-R-5 LPJ-5SP
2098-IPD-HV050 KTK-R-8 LPJ-8SP
2098-IPD-HV100 Input power KTK-R-20 LPJ-17-1/2SP
460V AC
2098-IPD-HV150 KTK-R-30 LPJ-30SP
2098-IPD-HV220 N/A LPJ-35SP
2098-IPD-HVxxx Auxiliary input power FNQ-R-10 LPJ-10SP
(1) Part numbers shown are examples of Bussmann fuses.
While circuit breakers offer some convenience, there are limitations for their use. Circuit breakers do not handle high
current inrush as well as fuses.
Make sure the selected components are properly coordinated and meet acceptable codes including any requirements for
branch circuit protection. Evaluation of the short-circuit available current is critical and must be kept below the
short-circuit current rating of the circuit breaker.
Input
Drive Cat. No. Circuit Breakers
Voltage
2098-IPD-HV030 140M-F8E-C16
2098-IPD-HV050 140M-F8E-C20
2098-IPD-HV100 460V 140M-F8E-C32
2098-IPD-HV150 140M-F8E-C45
2098-IPD-HV220 N/A
Contactor Ratings
Input
Drive Cat. No. Contactor
Voltage
100-C23x10 (AC coil)
2098-IPD-HV030 100-C23Zx10 (DC coil)
100-C30x10 (AC coil)
2098-IPD-HV050 100-C30Zx10 (DC coil)
100-C37x10 (AC coil)
2098-IPD-HV100 460V 100-C37Zx10 (DC coil)
100-C43x10 (AC coil)
2098-IPD-HV150 100-C43Zx10 (DC coil)
100-C60x10 (AC coil)
2098-IPD-HV220 100-C60Zx10 (DC coil)
Communication Specifications
Attribute Value
Serial
Ports Two RS-232/RS-422/RS-485
Communication rates 1200, 2400, 4800, 9600, 19200, and 38400 bps
DeviceNet interface (option)
Power consumption from 60 mA
network
Data rates 125, 250, and 500 kbps
Node addresses 00…63
Messaging capabilities Explicit, polled I/O
Inputs/Outputs Specifications
Attribute Value
General purpose digital inputs 16 optically isolated 12…24V inputs
Inputs/outputs - Software selectable as a group to be active high, current sinking or active low, current sourcing
sinking/sourcing selection
General purpose digital outputs 7 optically isolated 12…24V Outputs - 50 mA max
General purpose relay output 1 normally open relay - 30V DC max, 1 A max current
General purpose I/O response 100 µs
High speed input response < 1 µs (inputs 1 and 2)
Position capture response < 1 µs (input 1, input 2, motor encoder index, and auxiliary encoder index)
General purpose analog inputs 2 12-Bit analog to digital converters (+/- 10V, single-ended)
General purpose analog outputs 2 12-Bit digital to analog converters (+/- 10V, +/- 2mA, single-ended)
Memory Specifications
Attribute Value
User program memory capacity 512 Kbps
User program memory storage medium Flash memory, 100,000 write cycles
Non-volatile memory capacity 32 Kbps (approximately 8000 nonvolatile user variables)
Non-volatile memory storage medium nvSRAM (high-speed SRAM/EEPROM)
Connector Specifications
Connector Description Specification
28-position plugable spring clamp
CN1A Digital I/O connector terminal block
Auxiliary feedback/analog I/O 14-position plugable spring clamp
CN1B connector terminal block
15-pin high-density female D-sub
CN2 Motor feedback connector connector
CN3A and CN3B Serial port connectors 9-pin female D-sub connector
Main and auxiliary AC, DC bus,
TB1 and TB2 Screw terminal block
motor power, and shunt connectors
Although motor power and feedback cables are available in standard lengths up to 90 m (295.3 ft), the
drive/motor/feedback combination may limit the maximum feedback cable length. This table assumes the use of cables
recommended in the 2090-Series Motor/Actuator Cable Selection table on page 402.
In the figure below, -xxx is replaced by -005, -010, or -020 to represent the Ultra5000 500 W, 1 kW, and
2 kW drives respectively.
83.82
(3.30)
43.18 20.32 131.83
(1.70) (0.80) (5.19)
(1) 144.53
25.4
(1.0) (5.69)
43.18 20.32
(1.70) (0.80)
F
(1) This dimension applies to only the 2098-IPD-005-DN, 2098-IPD-010-DN, and 2098-IPD-020-DN (Ultra5000 with DeviceNet interface) models.
F
Ultra5000 Drive
mm (in.)
91.19
2098-IPD-005 (3.59)
2098-IPD-010-DN, 114.30
2098-IPD-020-DN (4.50)
In the figure below, -xxx is replaced by -030, -075, or -150 to represent the Ultra5000 3, 7.5, and 15 kW drives respectively.
A
B C 227.0
(8.94)
(1)
172.3
(6.78)
(1)
25.4 (1)
K
(1.0)
B C J
(1) This dimension only applies to the 2098-IPD-030-DN, 2098-IPD-075-DN, and 2098-IPD-150-DN (Ultra5000 with DeviceNet interface) models.
A B C J K
Ultra5000 Drive
mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
2098-IPD-030 92.7 50.8 20.3 243.9 149.3
2098-IPD-030-DN (3.65) (2.0) (0.8) (9.60) (5.88)
2098-IPD-075 141.0 88.9 24.3 247.3 152.7
2098-IPD-075-DN (5.55) (3.50) (0.96) (9.73) (6.01)
2098-IPD-150 190.5 69.9 24.9 245.1 146.5
2098-IPD-150-DN (7.5) (2.75) (0.98) (9.49) (5.77)
In the figure below, -xxx is replaced by -030, -050, -100, -150, or -220 to represent the Ultra5000 3, 5, 10, 15, and 22 kW
drives respectively.
A 225.8
B B C (8.89)
(1)
172.3
(6.78)
(1) (1)
25.4 148.8
B B 1.0 (5.86)
C 242.2
(9.54)
(1) This dimension applies to only the 2098-IPD-HV030-DN, 2098-IPD-HV050-DN, 2098-IPD-HV100-DN, 2098-IPD-HV150-DN, and 2098-IPD-HV220-DN (Ultra5000 with
DeviceNet interface) models.
A B C D H I
Ultra5000 Drive
mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
2098-IPD-HV030,
2098-IPD-HV030-DN, 138.7 18.5
2098-IPD-HV050, (5.46) (0.73)
2098-IPD-HV050-DN 50.8 349.3 331.5 360.7
2098-IPD-HV100, (2.0) (13.75) (13.05) (14.20)
2098-IPD-HV100-DN, 151.6 25.0
2098-IPD-HV150, (5.97) (0.99)
2098-IPD-HV150-DN
2098-IPD-HV220 203.2 76.2 25.4 380.41 362.6 391.8
2098-IPD-HV220-DN (8.0) (3.0) (1.0) (14.98) (14.28) (15.43)
DeviceNet
11
5 12
PWR
13
4
6
14
7
2
8
1 9
10
For CN1A, CN1B, CN2, and CN3 connector options, refer to Breakout Components and Connector Kits beginning on
page 442.
Statu s
Status
Internal
1 5
PWR
4 2
External Node Address
Addr e s s
Shunt (00-63, PGM)
3
TB2
TB2 6
C
N
3 7
A
C
DANGER N
3 8
B
D C Bus
DC Bu s
DeviceNet
U
12
V
3 Mot or
Motor 13
W C
N
2
9 14
+ CN1A
2 D C Bus
DC Bu s
15
-
L1
L2
10
L3
1 1100-240
0 0 -2 4 0 VAC
50/60
VA C
5 0 / 6 0 Hz
Hz
L1
AAUX
UX
L2/N
A UX
AUX 11
TB1
TB1
C N1B
CN1B
For CN1A, CN1B, CN2, and CN3 connector options, refer to Breakout Components and Connector Kits beginning on
page 442.
Node Address
Addr e s s
(00-63, PGM)
DANGER
DeviceNet
12
13
3
9 14
15
2
10
11
2098-IPD-HV030-DN, 2098-IPD-HV050-DN,
2098-IPD-HV030, 2098-IPD-HV050, 2098-IPD-HV100, 2098-IPD-HV100-DN, 2098-IPD-HV150-DN,
2098-IPD-HV150, and 2098-IPD-HV220 and 2098-IPD-HV220-DN
Ultra5000 Drives Ultra5000 DeviceNet Interface Drives
For CN1A, CN1B, CN2, and CN3 connector options, refer to Breakout Components and Connector Kits beginning on
page 442.
The Ultra3000 drives are configured by using Ultraware software (catalog number 2098-UWCPRG).
This chapter includes compatibility tables, dimensions, specifications, and catalog numbers for the accessories that support
the Kinetix Motion Control drive families.
2090-Series Motor/Actuator Cables Page Bulletin 2094 Drive Components for Kinetix 6000,
Page
Kinetix 6200, and Kinetix 6500 Drive Families
SpeedTec DIN Cable Features 396
Bulletin 2094 Power Rail 456
2090-Series Motor/Actuator Cables Overview 397
Bulletin 2094 Shunt Module 459
SpeedTec DIN Continuous-flex Extension Cables 399
Bulletin 2094 Slot-filler Module 464
2090-Series Motor Power and Feedback Transition Cables 400
Circular DIN Connector Compatibility Overview 401
2090-Series Motor/Actuator Cable Selection 402 Drive Accessories Kits Page
2090-Series Motor/Actuator Cable Specifications 411 Connector Sets 465
2090-Series Motor/Actuator Cable Dimensions 415 Kinetix Safe-off Components 466
2090-Series Motor-end Cable Connector Kits 424 Kinetix 2000 Cable Clamp Bracket Kit 468
2090-Series Bulkhead Adapter Kits 428 Bulletin 2094 Mounting Brackets 469
2090-Series Motor/Actuator Cable Catalog Numbers 430 Kinetix 7000 DC-DC Converter and Control Board Kits 470
External Auxiliary Encoders 471
2090-Series Interface Cables Page
Fiber-optic Cable Connection Examples 432
Drive Power Components Page
Ethernet Cable Connection Examples 434
Line Interface Modules 473
Interface Cable Applications and Standard Lengths 435
AC Line Filters 485
Interface Cable Specifications 436
External Shunt Modules 494
Interface Cable Dimensions 437
Resistive Brake Modules 500
2090-Series Interface Cable Catalog Numbers 440
8720MC Regenerative Power Supplies 504
8720MC Line Reactors 509
Breakout Boards and Connector Kits for
Page
I/O, Safety, and Feedback Connections
Low-profile Connector Kits 442
Low-profile Feedback Modules 446
Examples and
Specifications Drive-mounted Breakout Boards 447
Panel-mounted Breakout Boards 451
Drive-end Connector Kits 455
IMPORTANT All flying-lead feedback cables require breakout components or connector kits for drive-end terminations. Refer to
Breakout Components and Connector Kits beginning on page 442 for catalog numbers and descriptions.
IMPORTANT Standard (non-flex) cables have a regular maintenance and installation bend radius of 10 times (10x) the cable
diameter. For flexing applications, continuous-flex cables have an operational bend radius of 12 times (12x) the cable
diameter.
• Drive-end flying-leads
2090-XXNFMF-Sxx
• High-resolution or incremental applications
Threaded DIN
• Drive-end bayonet (E2), transition (TR) cable (1) (M4)
2090-CFBM4E2-CATR • Motor-end threaded DIN (M4)
• All feedback types (CA)
• Drive-end flying-leads (DF)
2090-CFBM6DF-CBAAxx • High-resolution, battery backup or
Incremental applications (CB)
Circular Plastic
(M6)
• Drive-end 15-pin connector (DD)
2090-CFBM6DD-CCAAxx
• Incremental applications only (CC)
(1) Threaded DIN connector (motor end) and bayonet connector for 2090-XXNFMP-Sxx cable. Refer to 2090-Series Motor Power and Feedback Transition Cables on page 400.
(1) SpeedTec DIN connector (motor end) and male connector for extending SpeedTec or threaded DIN cable. Refer to SpeedTec DIN Continuous-flex Extension Cables on
page 399.
IMPORTANT Feedback cables with the CE designation, for example 2090-CFBM7DF-CEAAxx, are intended for high-resolution encoder
or resolver applications and have fewer conductors than feedback cables with the CD designation, for example
2090-CFBM7DF-CDAFxx, which are intended for high-resolution or incremental encoder applications.
• Drive-end flying-leads
2090-XXNPMF-xxSxx
• Power/brake wires BR+
BR-
• Drive-end flying-leads
2090-DANPT-16Sxx
• Power wires only Rectangular
Plastic
2090-DANBT-18Sxx Drive-end flying-lead brake wires
(1) Threaded DIN connector (motor end) and bayonet connector for 2090-XXNFMP-Sxx cable. Refer to 2090-Series Motor Power and Feedback Transition Cables on page 400.
SpeedTec DIN
• Drive-end flying-leads (DF) (M7)
2090-CPWM7DF-xxAFxx
• Power wires only (PW)
(1) SpeedTec DIN connector (motor end) and male connector for extending SpeedTec or threaded DIN cable. Refer to SpeedTec DIN Continuous-flex Extension Cables on
page 399.
Motor power and feedback extension cables provide continuous-flex cable technology between your standard cable and the
continuous-flex application. Extension cables are available in lengths up to 30 m (98.4 ft). Extension power cables are
available in 16, 14, 10, and 8 AWG.
2090-XXNPMF-xxSxx or 2090-CPBM7E7-xxAFxx
2090-CPBM7DF-xxAAxx (standard) Continuous-flex (power/brake)
Circular DIN Power/Brake Cables Extension Cable
Servo Motor
2090-XXNFMF-Sxx, 2090-CFBM7E7-CDAFxx or
2090-CFBM7DF-CEAAxx, or 2090-CFBM7E7-CEAFxx
Servo Drive 2090-CFBM7DD-CEAAxx (standard) Continuous-flex (feedback)
Circular DIN Feedback Cables Extension Cable
6200
2090-KPB47-12CF
Bulkhead Adapter
SAFE SPEED
Machine with
(feedback)
Continuous-flex Cable Application
Continuous-flex Cable
Description Applications
Cat. No.
Intended for high-resolution or
2090-CFBM7E7-CDAFxx
Feedback extension cable, SpeedTec DIN incremental encoder applications.
(male/female) connectors Intended for high-resolution
2090-CFBM7E7-CEAFxx encoder or resolver applications.
Continuous-flex Cable
Description
Cat. No.
2090-CPBM7E7-16AFxx
2090-CPBM7E7-14AFxx Power/brake extension cable, SpeedTec DIN
2090-CPBM7E7-10AFxx (male/female) connectors
2090-CPBM7E7-08AFxx
Motor power/brake and feedback transition cables support installations where MP-Series (Bulletin MPL) motors with
bayonet connectors were recently replaced by the same motor with circular DIN connectors. These 0.5 m (19.7 in.) cables
provide a seamless transition between your new motor and existing power, brake, and feedback cables.
TIP Brake contacts for motors with bayonet connectors are in a separate connector. Power/brake cables with circular DIN
connectors (either threaded or SpeedTec) include brake contacts in the power/brake connector.
2090-XXNPMP-xxSxx (standard) or
2090-XXTPMP-xxSxx (continuous-flex) 2090-CPWM4E2-xxTR
Bayonet Power Cables Power-only Transition Cables
MP-Series
2090-CDNFDMP-Sxx, 2090-CFBM4E2-CATR Bulletin MPL
2090-UXNFBMP-Sxx, and Feedback Transition Cables Servo Motor
2090-XXNFMP-Sxx (standard) or
2090-XXTFMP-Sxx (continuous-flex) Machine transitioning from MP-Series
Servo drive in
Bayonet Feedback Cables (Bulletin MPL) motor with bayonet connectors to
existing application.
motor with threaded or SpeedTec-ready DIN connectors.
2090-XXNPMP-xxSxx (standard) or
2090-XXTPMP-xxSxx (continuous-flex) 2090-CPBM4E2-xxTR
Bayonet Power Cables Power/Brake Transition Cables
MP-Series
2090-XXNBMP-18Sxx (standard) or Bulletin MPL
2090-XXTBMP-18Sxx (continuous-flex Servo Motor
Bayonet Brake Cables
Servo drive in
2090-CFBM4E2-CATR
existing application. 2090-XXNFMP-Sxx and Feedback Transition Cables
2090-UXNFBMP-Sxx (standard) or
2090-XXTFMP-Sxx (continuous-flex) Machine transitioning from MP-Series
Bayonet Feedback Cables (Bulletin MPL) motor with bayonet connectors to
motor with threaded or SpeedTec-ready DIN connectors.
Motors equipped with either threaded or SpeedTec circular DIN connectors are listed below. Circular DIN motor
connectors rotate up to 180° and combine power and brake wires in the same connector.
Power-only or
Motor/Actuator Cat. No. Connector Type Feedback Cables
Power/Brake Cables
IMPORTANT Motors equipped with SpeedTec-ready DIN connectors are fully compatible with threaded DIN (M4) cable plugs.
SpeedTec-ready DIN motor connectors are also compatible with SpeedTec DIN (M7/E7) cable plugs when the o-ring
on the motor connector is removed.
Motors equipped with threaded DIN (M4) connectors are compatible only with threaded DIN (M4) cable plugs.
SpeedTec-ready
DIN Connector
• 2090-CFBM7DF-CEAAxx (standard) flying-lead, feedback cables
• Attach cable plug with one-quarter turn • 2090-CFBM7DD-CEAAxx (standard) drive-end connector, feedback cables
• Receives M4 and M7 cable plugs • 2090-CFBM7DF-CEAFxx (continuous-flex) flying-lead, feedback cables
(remove the O-ring for M7) • 2090-CFBM7DD-CEAFxx (continuous-flex) drive-end connector, feedback cables
• 2090-CFBM7DF-CDAFxx (continuous-flex) flying-lead, feedback cables
• 2090-CPWM7DF-xxAAxx (standard) power-only cables
• 2090-CPBM7DF-xxAAxx (standard) power/brake cables
• 2090-CPWM7DF-xxAFxx (continuous-flex) power-only cables
• 2090-CPBM7DF-xxAFxx (continuous-flex) power/brake cables
These tables provide flying-lead motor cable catalog numbers for drive/motor combinations. Most motor brake wires are in
the power cable, so a separate brake cable is not required (except where noted).
IMPORTANT The MP-Series low-inertia motors on this page are equipped with DIN connectors (specified by 4 or 7 in the catalog
number) and are not compatible with cables designed for motors equipped with bayonet connectors (specified by 2 in
the catalog number). The motors with bayonet connectors (for example, MPL-A310P-xx2xAA) are being discontinued
and require 2090-XXNFMP-Sxx (bayonet) cables. For help with migration or to select bayonet cables, contact your
Rockwell Automation sales representative.
Motor Cat. No. Compatible Drive Cat. No. Feedback Type Feedback Cable Cat. No.
2093-AC05-MPx or 2093-AMxx
MPL-A15xxx-V/Ex4xAA, 2094-ACxx-Mxx-S or 2094-AMxx-S
MPL-A2xxx-V/Ex4xAA 2097-V3xxxx
2098-DSD-xxx 2090-XXNFMF-Sxx (standard)
2094-BCxx-Mxx-S or 2094-BMxx-S 2090-CFBM4DF-CDAFxx (continuous-flex)
MPL-B15xxx-V/Ex4xAA, 2094-BCxx-Mxx-M or 2094-BMxx-M
MPL-B2xxx-V/Ex4xAA 2097-V3xxxx
2098-DSD-HVxxx
Multi-turn High-resolution
2093-AC05-MPx or 2093-AMxx Absolute
MPL-A3xxx-M/Sx7xAA,
MPL-A4xxx-M/Sx7xAA, 2094-ACxx-Mxx-S or 2094-AMxx-S or
MPL-A45xxx-M/Sx7xAA, 2097-V3xxxx Single-turn High-resolution
MPL-A5xxx-M/Sx7xAA 2098-DSD-xxx Encoder Feedback
2098-IPD-xxx 2090-CFBM7DF-CEAAxx or
2090-CFBM7DD-CEAAxx (standard)
MPL-B3xxx-M/Sx7xAA, 2094-BCxx-Mxx-S or 2094-BMxx-S
MPL-B4xxx-M/Sx7xAA, 2090-CFBM7DF-CEAFxx
2094-BCxx-Mxx-M or 2094-BMxx-M
MPL-B45xxx-M/Sx7xAA, 2090-CFBM7DD-CEAFxx (continuous-flex)
2097-V3xxxx
MPL-B5xxx-M/Sx7xAA, 2098-DSD-HVxxx
MPL-B6xxx-M/Sx7xAA, 2098-IPD-HVxxx
MPL-B8xxx-M/Sx7xAA, 2099-BMxx-S
MPL-B9xxx-M/Sx7xAA
2093-AC05-MPx or 2093-AMxx
MPL-A15xxx-Hx4xAA, 2094-ACxx-Mxx-S or 2094-AMxx-S
MPL-A2xxx-Hx4xAA 2097-V3xxxx
2098-DSD-xxx 2090-XXNFMF-Sxx (standard)
2094-BCxx-Mxx-S or 2094-BMxx-S 2090-CFBM4DF-CDAFxx (continuous-flex)
MPL-B15xxx-Hx4xAA, 2094-BCxx-Mxx-M or 2094-BMxx-M
MPL-B2xxx-Hx4xAA 2097-V3xxxx Incremental (1)
2098-DSD-HVxxx Feedback
2093-AC05-MPx or 2093-AMxx
MPL-A3xxx-Hx7xAA, 2094-ACxx-Mxx-S or 2094-AMxx-S 2090-XXNFMF-Sxx (standard)
MPL-A4xxx-Hx7xAA, 2097-V3xxxx 2090-CFBM7DF-CDAFxx (continuous-flex)
MPL-A45xxx-Hx7xAA 2098-DSD-xxx
2098-IPD-xxx
2090-CFBM7DF-CEAAxx (standard)
MPL-Bxxxx-Rx7xAA 2094-BCxx-Mxx-S or 2094-BMxx-S Resolver Feedback (1) 2090-CFBM7DF-CEAFxx (continuous-flex)
(1) Not all MP-Series low-inertia motors are available with incremental and resolver feedback options.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
IMPORTANT The MP-Series low-inertia motors on this page are equipped with DIN connectors (specified by 4 or 7 in the catalog
number) and are not compatible with cables designed for motors equipped with bayonet connectors (specified by 2 in
the catalog number). The motors with bayonet connectors (for example, MPL-A310P-xx2xAA) are being discontinued
and require 2090-XXNPMP-xxSxx (bayonet) cables. For help with migration or to select bayonet cables, contact your
Rockwell Automation sales representative.
MPL-B520K-xx7xAA
MPL-B540D-xx7xAA, 2090-CPxM7DF-14AAxx (standard)
MPL-B540K-xx7xAA, 2090-CPxM7DF-14AFxx (continuous-flex)
MPL-B560F-xx7xAA
MPL-B580F-xx7xAA,
MPL-B580J-xx7xAA 2090-CPxM7DF-10AAxx (standard)
2090-CPxM7DF-10AFxx (continuous-flex)
MPL-B640F-xx7xAA
MPL-B660F-xx7xAA, MPL-B680D-xx7xAA, 2090-CPxM7DF-08AAxx (standard)
MPL-B960B-xx7xAA, MPL-B980B-xx7xAA 2090-CPxM7DF-08AFxx (continuous-flex)
MPL-B680F-xx7xAA, 2090-CPBM7DF-06AAxx (standard)
MPL-B860D-xx7xAA, MPL-B880C-xx7xAA,
MPL-B880D-xx7xAA
MPL-B960C-xx7xAA, MPL-B960D-xx7xAA, 2090-CPBM7DF-04AAxx (standard)
MPL-B980C-xx7xAA, MPL-B980D-xx7xAA
MPL-B980E-xx7xAA 2090-CPBM7DF-02AAxx (standard)
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor Cat. No. Drive Compatibility Feedback Type Feedback Cable Cat. No.
2093-AC05-MPx or 2093-AMxx
2094-ACxx-Mxx-S or 2094-AMxx-S
MPF-Axxxx-M/S 2097-V3xxxx
2098-DSD-xxx 2090-CFBM7DF-CEAAxx or
Multi-turn High Resolution
2098-IPD-xxx 2090-CFBM7DD-CEAAxx (standard)
Absolute or
2094-BCxx-Mxx-S or 2094-BMxx-S Single-turn High Resolution 2090-CFBM7DF-CEAFxx
2094-BCxx-Mxx-M or 2094-BMxx-M Encoder Feedback 2090-CFBM7DD-CEAFxx (continuous-flex)
MPF-Bxxxx-M/S 2097-V3xxxx
2098-DSD-HVxxx
2098-IPD-HVxxx
2090-CPxM7DF-14AAxx (standard)
MPF-A430P, MPF-A4530K and MPF-A4540F 2090-CPxM7DF-14AFxx (continuous-flex)
2090-CPxM7DF-08AAxx (standard)
MPF-A540K 2090-CPxM7DF-08AFxx (continuous-flex)
2090-CPxM7DF-10AAxx (standard)
MPF-B540K 2090-CPxM7DF-10AFxx (continuous-flex)
Motor Cat. No. Drive Compatibility Feedback Type Feedback Cable Cat. No.
2093-AC05-MPx or 2093-AMxx
2094-ACxx-Mxx-S or 2094-AMxx-S
MPS-Axxxx-M/S 2097-V3xxxx
2098-DSD-xxx Multi-turn High Resolution Absolute
2098-IPD-xxx or 2090-XXNFMF-Sxx (standard)
2094-BCxx-Mxx-S or 2094-BMxx-S Single-turn High Resolution 2090-CFBM4DF-CDAFxx (continuous-flex)
2094-BCxx-Mxx-M or 2094-BMxx-M Encoder Feedback
MPS-Bxxxx-M/S 2097-V3xxxx
2098-DSD-HVxxx
2098-IPD-HVxxx
2090-XXNPMF-14Sxx (standard)
MPS-B560F
2090-CPxM4DF-14AFxx (continuous-flex)
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor Cat. No. Drive Compatibility Feedback Type Feedback Cable Cat. No.
2093-AC05-MPx or 2093-AMxx
2094-ACxx-Mxx-S or 2094-AMxx-S
MPM-Axxxxx-M/S 2097-V3xxxx 2090-CFBM7DF-CEAAxx or
2098-DSD-xxx Multi-turn High Resolution Absolute 2090-CFBM7DD-CEAAxx (standard)
or
2094-BCxx-Mxx-S or 2094-BMxx-S Single-turn High Resolution
2094-BCxx-Mxx-M or 2094-BMxx-M 2090-CFBM7DF-CEAFxx
Encoder Feedback
MPM-Bxxxxx-M/S 2097-V3xxxx 2090-CFBM7DD-CEAFxx (continuous-flex)
2098-DSD-HVxxx
2099-BMxx-S
MPM-Axxxxx-2 2094-ACxx-Mxx-S or 2094-AMxx-S 2090-CFBM7DF-CEAAxx (standard)
Resolver Feedback (1) 2090-CFBM7DF-CEAFxx (continuous-flex)
MPM-Bxxxxx-2 2094-BCxx-Mxx-S or 2094-BMxx-S
(1) Not all MP-Series medium-inertia motors are available with the resolver feedback option.
MP-Series (200V Class) Medium Inertia Motors Power Cable Cat. No.
2090-CPxM7DF-16AAxx (standard)
MPM-A115xx 2090-CPxM7DF-16AFxx (continuous-flex)
2090-CPxM7DF-14AAxx (standard)
MPM-A1302F 2090-CPxM7DF-14AFxx (continuous-flex)
MPM-A1304F 2090-CPxM7DF-12AAxx (standard)
2090-CPxM7DF-10AAxx (standard)
MPM-A1651F 2090-CPxM7DF-10AFxx (continuous-flex)
2090-CPxM7DF-08AAxx (standard)
MPM-A1652F, MPM-A1653F 2090-CPxM7DF-08AFxx (continuous-flex)
MPM-A215xx 2090-CPBM7DF-06AAxx (standard)
MP-Series (400V Class) Medium Inertia Motors Power Cable Cat. No.
MPM-B1151x, MPM-B1152x
MPM-B1153E, MPM-B1153F 2090-CPxM7DF-16AAxx (standard)
MPM-B1302F, MPM-B1302M, MPM-B1304C, MPM-B1304E 2090-CPxM7DF-16AFxx (continuous-flex)
MPM-B1651C, MPM-B1652C
MPM-B1153T
2090-CPxM7DF-14AAxx (standard)
MPM-B1302T, MPM-B1304M 2090-CPxM7DF-14AFxx (continuous-flex)
MPM-B1651F, MPM-B1653C
MPM-B1651M, MPM-B1652E, MPM-B1652F, MPM-B1653E 2090-CPxM7DF-10AAxx (standard)
MPM-B2152C, MPM-B2153B 2090-CPxM7DF-10AFxx (continuous-flex)
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor Cat. No. Drive Compatibility Feedback Type Feedback Cable Cat. No.
Multi-turn High Resolution Absolute
2094-BCxx-Mxx-S or 2094-BMxx-S or 2090-XXNFMF-Sxx (standard)
RDB-Bxxxx-7/3 2094-BCxx-Mxx-M or 2094-BMxx-M Single-turn High Resolution 2090-CFBM7DF-CDAFxx (continuous-flex)
2099-BMxx-S Encoder Feedback
RDD-Series (400V Class) Direct Drive Motors Power Cable Cat. No.
RDB-B21519, RDB-B21529 2090-CPWM7DF-16AAxx (standard)
RDB-B29014, RDB-B29016, RDB-B29024 2090-CPWM7DF-16AFxx (continuous-flex)
RDB-B2152C
2090-CPWM7DF-12AAxx (standard)
RDB-B29026
RDB-B2153C 2090-CPWM7DF-10AAxx (standard)
RDB-B29036, RDB-B41014 2090-CPWM7DF-10AFxx (continuous-flex)
2090-CPWM7DF-08AAxx (standard)
RDB-B29029, RDB-B41016, RDB-B41024 2090-CPWM7DF-08AFxx (continuous-flex)
RDB-B29039, RDB-B41018, RDB-B41026, RDB-B41035 2090-CPBM7DF-06AAxx (standard)
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Cat. No. Drive Compatibility Feedback Type Feedback Cable Cat. No.
Multi-turn High Resolution Absolute
HPK-Bxxxxx-M/S or 2090-XXNFMF-Sxx (standard)
2099-BMxx-S
HPK-Exxxxx-M/S Single-turn High Resolution 2090-CFBM4DF-CDAFxx (continuous-flex)
Encoder Feedback
Cat. No. Drive Compatibility Feedback Type Feedback Cable Cat. No.
2093-AC05-MPx or 2093-AMxx
2094-ACxx-Mxx-S or 2094-AMxx-S
2097-V3xxxx
TLY-Axxxx-H Incremental 2090-CFBM6DF-CBAAxx (flying lead) or
2098-DSD-xxx
2098-IPD-xxx 2090-CFBM6DD-CCAAxx
2071-Axx (premolded connector)
2093-AC05-MPx or 2093-AMxx
TLY-Axxxx-B 2097-V3xxxx
Multi-turn High Resolution Absolute
2071-Axx Encoder Feedback 2090-CFBM6DF-CBAAxx (flying lead)
TL-Axxxx-B 2071-Axx 2090-DANFCT-Sxx
TLY-Axxxx-B 2090-CPWM6DF-16AAxx
(power without brake)
TL-Axxxx-B 2090-DANPT-16Sxx
IMPORTANT TL-Axxxx-B motors have rectangular plastic connectors and are intended for use with Kinetix 3 (Bulletin 2071) servo
drives. The TLY-Axxxx motors have circular plastic connectors and are intended for use with Bulletin 2093, 2094, 2097,
and 2098 (230V) servo drives.
Actuator Cat. No. Drive Compatibility Feedback Type Feedback Cable Cat. No.
2093-AC05-MPx or 2093-AMxx
MPAS-Axxxxx-V/A or 2094-ACxx-Mxx-S or 2094-AMxx-S
MPMA-A 2098-DSD-xxx
MPAS-Axxxxx-A or 2097-V3xxxx
MPMA-A
MPAS-Axxxxx-V 2071-Axx Multi-turn High Resolution Absolute 2090-XXNFMF-Sxx (standard)
Encoder Feedback 2090-CFBM4DF-CDAFxx (continuous-flex)
2094-BCxx-Mxx-S or 2094-BMxx-S
MPAS-Bxxxxx-V/A or 2094-BCxx-Mxx-M or 2094-BMxx-M
MPMA-B 2097-V3xxxx
2098-DSD-HVxxx
MPAS-Bxxxxx-A or 2097-V3xxxx
MPMA-B
Actuator Cat. No. Drive Compatibility Feedback Type Motor Feedback Cable
2093-AC05-MPx or 2093-AMxx 2090-CFBM6DF-CBAAxx (flying-lead) or
TLAR-Axxxxx Multi-turn High Resolution Absolute
2097-V3xxxx 2090-CFBM6DD-CCAAxx
Encoder Feedback
2071-Axx (premolded connector) standard
Actuator Cat. No. Drive Compatibility Feedback Type Feedback Cable Cat. No.
2093-AC05-MPx or 2093-AMxx
MPAR-A1xxxx 2094-ACxx-Mxx-S or 2094-AMxx-S
MPAR-A2xxxx 2097-V3xxxx
2098-DSD-xxx 2090-XXNFMF-Sxx (standard)
2094-BCxx-Mxx-S or 2094-BMxx-S 2090-CFBM4DF-CDAFxx (continuous-flex)
MPAR-B1xxxx 2094-BCxx-Mxx-M or 2094-BMxx-M
MPAR-B2xxxx 2097-V3xxxx
2098-DSD-HVxxx Multi-turn High Resolution Absolute
2093-AC05-MPx or 2093-AMxx Encoder Feedback
2094-ACxx-Mxx-S or 2094-AMxx-S
MPAR-A3xxxx 2090-CFBM7DF-CEAAxx or
2097-V3xxxx
2098-DSD-xxx 2090-CFBM7DD-CEAAxx (standard)
2094-BCxx-Mxx-S or 2094-BMxx-S 2090-CFBM7DF-CEAFxx
2094-BCxx-Mxx-M or 2094-BMxx-M 2090-CFBM7DD-CEAFxx (continuous-flex)
MPAR-B3xxxx 2097-V3xxxx
2098-DSD-HVxxx
Actuator Cat. No. Drive Compatibility Feedback Type Feedback Cable Cat. No.
2093-AC05-MPx or 2093-AMxx
MPAI-A3xxxx 2094-ACxx-Mxx-S or 2094-AMxx-S
MPAI-A4xxxx 2097-V3xxxx 2090-CFBM7DF-CEAAxx or
2098-DSD-xxx 2090-CFBM7DD-CEAAxx (standard)
Multi-turn High Resolution Absolute
2094-BCxx-Mxx-S or 2094-BMxx-S Encoder Feedback 2090-CFBM7DF-CEAFxx
MPAI-B3xxxx 2094-BCxx-Mxx-M or 2094-BMxx-M 2090-CFBM7DD-CEAFxx (continuous-flex)
MPAI-B4xxxx 2097-V3xxxx
2098-DSD-HVxxx
MP-Series (230V) Heavy Duty Electric Cylinders Power Cable Cat. No.
MPAI-A3xxxx 2090-CPxM7DF-16AAxx (standard)
MPAI-A4xxxx 2090-CPxM7DF-16AFxx (continuous-flex)
MP-Series (460V) Heavy Duty Electric Cylinders Power Cable Cat. No.
MPAI-B3xxxx 2090-CPxM7DF-16AAxx (standard)
MPAI-B4xxxx 2090-CPxM7DF-16AFxx (continuous-flex)
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Cat. No. Drive Compatibility Feedback Type Feedback Cable Cat. No.
2093-AC05-MPx or 2093-AMxx
LDC-Cxxxxxx-xxTx1 2094-ACxx-Mxx-S or 2094-AMxx-S
(230V operation) 2098-DSD-xxx
2071-Axx Sin/Cos or TTL 2090-XXNFMF-Sxx (standard)
Encoder Feedback 2090-CFBM7DF-CDAFxx (continuous-flex)
LDC-Cxxxxxx-xxTx1 2094-BCxx-Mxx-S or 2094-BMxx-S
2094-BCxx-Mxx-M or 2094-BMxx-M
(460V operation) 2098-DSD-HVxxx
LDC-Series (230V or 460V operation) Linear Motors Power Cable Cat. No.
2090-CPWM7DF-16AAxx (standard)
LDC-Cxxxxxx-xxTx1 2090-CPWM7DF-16AFxx (continuous-flex)
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Cat. No. Drive Compatibility Feedback Type Feedback Cable Cat. No.
2093-AC05-MPx or 2093-AMxx
2094-ACxx-Mxx-S or 2094-AMxx-S Sin/Cos or TTL 2090-XXNFMF-Sxx (standard)
LDL-xxxxxxx-xxTx1 2090-CFBM7DF-CDAFxx (continuous-flex)
2098-DSD-xxx Encoder Feedback
2071-Axx
Power Cables (1) Cable Type/ Wire Size Weight, Standard Cable Lengths
Description approx.
Cat. No. Jacket Color AWG m (ft)
kg/m (lb/ft)
2090-XXNPMF-16Sxx Four conductor, 600V, shielded cable for 16 0.276 (0.186)
Standard cable three-phase power with additional four
Industrial TPE,
2090-XXNPMF-14Sxx conductors, 18 AWG, shielded, for motor 14 0.315 (0.212)
Black brake and spares.
2090-CPBM7DF-16AAxx 16 0.212 (0.143)
2090-CPBM7DF-14AAxx 14 0.261 (0.175)
2090-CPBM7DF-12AAxx Four conductor, 600V, shielded cable for 12 0.349 (0.235)
three-phase power with additional two
2090-CPBM7DF-10AAxx conductors 18 AWG for motor brake. 10 0.492 (0.331)
1 (3.2) 7 (22.9) 25 (82.0)
2090-CPBM7DF-08AAxx 8 0.708 (0.476) 2 (6.5) 9 (29.5) 30 (98.4)
Standard cable 3 (9.8) 12 (39.4) 40 (131.2)
2090-CPBM7DF-06AAxx 6 1.038 (0.698) 4 (13.1) 15 (49.2) 60 (196.8)
2090-CPBM7DF-04AAxx Industrial TPE, Four conductor, 600V, shielded cable for 4 1.549 (1.041) 5 (16.4) 20 (65.6) 90 (295.3)
Orange three-phase power with additional two
2090-CPBM7DF-02AAxx (DESINA, RAL conductors 16 AWG for motor brake. 2 2.166 (1.455)
2003)
2090-CPWM7DF-16AAxx 16 0.136 (0.091)
2090-CPWM7DF-14AAxx 14 0.185 (0.124)
2090-CPWM7DF-12AAxx 12 0.248 (0.167)
Four conductor, 600V, shielded cable for
2090-CPWM7DF-10AAxx 10 0.418 (0.281)
three-phase power.
2090-CPWM7DF-08AAxx 8 0.644 (0.433)
2090-CPWM6DF-16AAxx 16 1 (3.2) 5 (16.4) 15 (49.2)
Standard cable 0.138 (0.093) 2 (6.5) 7 (22.9) 20 (65.6)
2090-DANPT-16Sxx Industrial TPE, 16 3 (9.8) 9 (29.5) 25 (82.0)
Black
2090-CPBM6DF-16AAxx 16 0.180 (0.121) 4 (13.1) 12 (39.4) 30 (98.4)
2090-CPBM4DF-16AFxx 16
0.228 (0.153)
2090-CPBM7DF-16AFxx Four conductor, 600V, shielded cable for 16
three-phase power with additional two
2090-CPBM7DF-14AFxx conductors 18 AWG for motor brake. 14 0.289 (0.194)
2090-CPBM7DF-10AFxx Continuous-flex 10 0.513 (0.345) 1 (3.2)
cable 9 (29.5)
2 (6.5) 40 (131.2)
12 (39.4)
2090-CPBM7DF-08AFxx 8 0.697 (0.468) 3 (9.8) 50 (164.0)
Industrial TPE, 15 (49.2)
4 (13.1) 60 (196.8)
2090-CPWM4DF-16AFxx Orange 16 20 (65.6) 75 (264.0)
(DESINA, RAL 0.154 (0.104) 5 (16.4) 25 (82.0) 90 (295.3)
2090-CPWM7DF-16AFxx 2003) 16 7 (22.9) 30 (98.4)
Four conductor, 600V, shielded cable for
2090-CPWM7DF-14AFxx three-phase power. 14 0.196 (0.132)
2090-CPWM7DF-10AFxx 10 0.452 (0.304)
2090-CPWM7DF-08AFxx 8 0.666 (0.448)
(1) 2090-CPxM4DF-xxAxxx and 2090-CPxM7DF-xxAxxx power cables are UL Listed, bulk cable, type TC-ER.
Brake Cables Cable Type/ Wire Size Weight, Standard Cable Lengths
Description approx.
Cat. No. Jacket Color AWG m (ft)
kg/m (lb/ft)
Notes:
Brown
Black
A Blue
Green/Yellow
Cable Shield
2090-CPBM7DF-xxAAxx (overall)
04…02 AWG
Cable Shield
BR (overall) Cable Shield
Bend Radius (for brake wires) 2090-XXNPMF-xxSxx
Typical End View
Brown
C Black
D E Blue
Green/Yellow
Brown
Black
Blue
Cable Shield Green/Yellow
(overall) 2090-CPWM4DF-xxAFxx
Cable Green/Yellow
Connector Diameter
Diameter
2090-CPBM6DF-16AAxx
Brown
12.2 Black
(0.48) Cable Shield (overall)
Blue
Green/Yellow
MBRK+
BR 300 (11.8)
Bend Radius
C
D
34.0
(1.3)
16.0
Cable (0.6)
Connector Diameter 34.0
Diameter
50.0 (1.3)
(2.0)
33.5
(1.3)
2090-XXNFMF-Sxx
BR Bend Radius 2090-CFBM4DF-CDAFxx
C
D
Cable
Connector Diameter
Diameter
16.0
Cable Minimum Bend Radius = 96.5 (3.8) (0.6)
Diameter
50.0 34.0
(2.0) (1.3)
33.5
(1.3)
Cable
Diameter 2090-CFBM6DD-CCAAxx
Connector
Diameter 16.0
(0.6)
50.0
(2.0)
9.7
(0.4)
45°
47.6 Cable
(1.9) Diameter
34.0
(1.3)
33.5
(1.3)
56.9 15
35
(2.24) (0.60)
(1.38) 24
45° or 60° (0.93)
41.2 30.0
(1.62) (1.18)
9.6
14.0 (0.38) Minimum Bend Radius = 64 (2.5)
(0.55)
2090-CPBM7E7-16AFxx
BR
2090-CPBM7E7-14AFxx
C
Bend Radius
D
Cable
Connector Diameter 2090-CPBM7E7-10AFxx
Diameter 2090-CPBM7E7-08AFxx
Cable Diameter
Connector 2090-CFBM7E7-CDAFxx
Diameter 2090-CFBM7E7-CEAFxx
Bend Radius
Connector Cable
BR Bend Radius Diameter
Diameter
2090-CPBM4E2-xxTR
500 (19.7)
90
(3.54)
C A D
Cable
Connector Diameter
Diameter
24
(0.94)
26 500 (19.7)
(1.0) 58 Dimensions are in mm (in.) 10 90
(2.3) (reference only) (0.39) (3.5)
31
(1.2)
Cable
Connector Diameter
BR Bend Radius
Diameter
12
(0.47) Bend Radius = 15 (0.59) 7.6
(0.30)
Motor-end connector kits are available for building your own cables. Kits are available for bayonet, circular DIN (M4 and
M7), and circular plastic (M6) cable connectors.
2090-KFBM4-CAAA
2090-KFBM7-CAAA Connector pins and sockets in
Motor-end Connector Kits these kits are soldered.
2090-KFBE7-CAAA
Motor-end Connector Kits
2090-KPBM4-12AA
2090-KPBM4-06AA Connector pins and sockets in
2090-KPBM7-12AA these kits are crimped.
2090-KPBM7-06AA
Motor-end Connector Kits
2090-KPBE7-12AA
2090-KPBE7-06AA
Motor-end Connector Kits
The tables beginning on page 426 provide a cross-reference for the circular DIN (M4 and M7) connector kits above to the
compatible motor series catalog number. Also provided are the bulkhead adapters for securing the cables as they pass
through the cabinet and crimping tools required for properly attaching the power wires to sockets and pins.
Connector kits and crimping tools are also available for circular plastic (M6) connectors. Refer to page 427 for the
compatible motor series and crimp tool catalog numbers.
426
Connector Kit Crimp Tool
Description Bulkhead Adapter Motor Series
Chapter 12
427
Chapter 12
Chapter 12 Motion Control Accessories
These bulkhead adapter kits let you secure your cables as they pass through the cabinet and apply to circular DIN (M4 and
M7) power and feedback cables.
Connector
Bulkhead Adapter Standard (non-flex) Continuous-flex Diameter
Description
Cat. No. Power Cable Cat. No. Power Cable Cat. No.
mm (in.)
2090-CPWM7DF-16AAxx 2090-CPWM7DF-16AFxx
2090-CPWM7DF-14AAxx 2090-CPWM7DF-14AFxx Power only
2090-CPWM7DF-12AAxx N/A
2090-CPBM7DF-16AAxx 2090-CPBM7DF-16AFxx
SpeedTec DIN
2090-CPBM7DF-14AAxx 2090-CPBM7DF-14AFxx
2090-KPB47-12CF 2090-CPBM7DF-12AAxx N/A Power/brake 28.0 (1.1)
N/A 2090-CPBM7E7-16AAxx
N/A 2090-CPBM7E7-14AAxx
N/A 2090-CPWM4DF-16AFxx Power only
N/A 2090-CPBM4DF-16AFxx Threaded DIN
Power/brake
2090-XXNPMF-16Sxx N/A
2090-CPWM7DF-10AAxx 2090-CPWM7DF-10AFxx
Power only
2090-CPWM7DF-08AAxx 2090-CPWM7DF-08AFxx
2090-KPB47-06CF 2090-CPBM7DF-10AAxx 2090-CPBM7DF-10AFxx SpeedTec DIN 45.0 (1.8)
2090-CPBM7DF-08AAxx 2090-CPBM7DF-08AFxx Power/brake
2090-CPBM7DF-06AAxx N/A
Connector
Bulkhead Adapter Standard (non-flex) Continuous-flex Diameter
Description
Cat. No. Feedback Cable Cat. No. Feedback Cable Cat. No.
mm (in.)
2090-CFBM7DF-CEAAxx 2090-CFBM7DF-CEAFxx
2090-CFBM7DD-CEAAxx 2090-CFBM7DD-CEAFxx
2090-KPB47-12CF N/A 2090-CFBM7DF-CDAFxx SpeedTec DIN 28.0 (1.1)
N/A 2090-CFBM7E7-CDAFxx
Feedback
N/A 2090-CFBM7E7-CEAFxx
2090-CFBM4DF-CEAAxx N/A
2090-KFB47-CF N/A 2090-CFBM4DF-CDAFxx Threaded DIN 26.0 (1.0)
2090-XXNFMF-Sxx N/A
45°
Ø47.0
45°
Ø27.3 H11
H11
0
Ø4
0
Ø6
M3 Ø4.2
(0.16) M4 Ø5.2
Dimensions are in mm (in.) (0.20)
2090-KFB47-CF and 2090-KPB47-12CF 2090-KPB47-06CF
(M23) Bulkhead Adapter Kits (M40) Bulkhead Adapter Kits
C
C C
A B A B
A B
2090 - C xx Mx Dx - Cx Ax xx
Cable Length
Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Cable Type
AA = Standard
AF = Continuous-flex
Encoder Type (applies to feedback cables)
CB = Serial incremental/Serial absolute - battery backup
CC = Serial incremental/Incremental
CD = SIN/COS High-resolution/Incremental
CE = SIN/COS High-resolution/Resolver
Wire Gauge Size (applies to power cables)
16, 14, 12, 10, 8, 6, 4, and 2 AWG
Drive-end Connector Type
DF = Drive-end, flying-lead
DD = Drive-end, D-sub connector
E7 = Extension receptacle (SpeedTec ready)
Motor-end Connector Type
M6 = Circular plastic connector
M4 = Threaded DIN connector
M7 = SpeedTec DIN connector
Cable Type
PB = Motor power with brake wires
PW = Motor power only
FB = Motor feedback only
Accessory Component
C = Cable
Bulletin Number
Transition Cables
2090 - xx x xx xx - xx S xx
Cable Length
Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor Connector
S = Straight
Wire Gauge Size (AWG)
16 = Motor power cable
18 = Motor brake cables
Blank = Feedback cables
Motor/Actuator Series
MF = Threaded DIN Connectors
MPS-A/Bxxxx (MPS-A/Bxxxx-M/S)
HPK-B/Exxxx (HPK-B/Exxxxx-M/S)
MPAS-A/Bxxxx (MPAS-A/Bxxxxx-V/A) or MPMA-A/Bxxxx
T = TLY-Axxxx (TLY-Axxxx-B/H)
Cable Type
P = Motor power
F = Motor feedback connector (flying-leads at drive)
FC = Motor feedback (connectors at both ends, TL-Series)
FM = Motor feedback (flying-leads to D-sub at drive)
B = Motor brake
Flex Option
N = Standard cable (non-flex)
Drive Family
DA = Kinetix 3 drives
XX = All other drives
Bulletin Number
The length of each transmission section (point A to B) can be up to 32 m (105 ft) for plastic cable and 50…200 m
(164.2…656.7 ft) for glass cable. In this example, the second Kinetix 7000 drive is located in a separate cabinet and
connected with bulkhead adapters.
ControlLogix
Chassis SERCOS Fiber-optic Ring SERCOS Fiber-optic Ring
A B A B
B A SERCOS Fiber Optic
Bulkhead Adapter
A A
B B
Kinetix 7000 Drive Kinetix 7000 Drive
Ultra3000-SE Drive Ultra3000-SE Drive
IMPORTANT To avoid signal loss, do not use bulkhead adapters to connect glass cables. Use bulkhead adapters for making
plastic-to-plastic cable connections only.
Multi-axis servo drives with SERCOS interface have specific cable lengths for making drive-to-drive connections for
single-wide and double-wide modules.
Cable Length
IAM Module Adjacent AM Module Cable Cat. No.
m (in.)
2093-AMP1, 2093-AMP2, or 2093-AMP5 Single-wide 2090-SCEP0-1 0.1 (5.1)
Kinetix 2000
2093-AM01 or 2093-AM02 Double-wide 2090-SCEP0-2 0.2 (7.1)
2094-AMxx-S, 2094-BMP5-S, 2094-BM01-S, or 2090-SCEP0-1 0.1 (5.1)
2094-BM02-S Single-wide
Kinetix 6000 2094-BMP5-M, 2094-BM01-M, or 2094-BM02-M
2090-SCEP0-2 0.2 (7.1)
2094-BM03-S and 2094-BM05-S Double-wide
2094-BMP5-M, 2094-BM01-M, or 2094-BM02-M 2090-SCEP0-2 0.2 (7.1)
2094-AMxx-S, 2094-BMP5-S, 2094-BM01-S, or Single-wide
Kinetix 6200 2090-SCEP0-1 0.1 (5.1)
2094-BM02-S
2094-BM03-M and 2094-BM05-M Double-wide 2090-SCEP0-3 0.3 (12.0)
Drive-to-Drive Fiber-optic Cable Length Example (Kinetix 2000 and Kinetix 6000 drives)
1756-M16SE SERCOS
Interface Module
SERCOS interfaceTM
SERCOS Fiber-optic Ring
CP OK
Logix Platform
0.2 m 0.1 m
Tx (rear)
Rx (front)
0.2 m 0.1 m (7.1 in.) (5.1 in.)
(7.1 in.) (5.1 in.)
Drive-to-Drive Fiber-optic Cable Length Example (Kinetix 6000 and Kinetix 6200 drives)
1756-M16SE SERCOS
Interface Module Kinetix 6000 (top view) SERCOS Fiber-optic Ring
SERCOS interfaceTM
SERCOS Connectors
Logix Platform
CP OK
Tx (rear)
Rx (front)
0.1 m
0.2 m (5.1 in.) 0.2 m SERCOS Fiber-optic Ring 0.2 m 0.1 m
(7.1 in.) (7.1 in.) (7.1 in.) (5.1 in.)
CP OK
Rx (front)
IAM Power Module
(Bulletin 2094 4-axis power rail)
Shielded Ethernet cable is available in lengths up to 78 m (256 ft). However, the total length of Ethernet cable (point A to
point B) connecting drive-to-drive, drive-to-controller, or drive-to-switch must not exceed 100 m (328 ft).
ControlLogix Platform
B A
1756-ENxTR EtherNet/IP
Module 2094-BMxx-M Single-wide AM Power Module
with 2094-EN02D-M01-Sx Control Module
ControlLogix Platform 2094-BMxx-M Double-wide AM Power Module
with 2094-EN02D-M01-Sx Control Module
1585J-M8CBJM-x
Ethernet (shielded) Cable
1 (3.2)
2090-CCMDSDS-48AAxx Kinetix 3 control interface cable for drive-to-drive configurations 0.3 (0.98)
2090-CCMPCDS-23AAxx Kinetix 3 serial interface cable to personal computer
1 (3.2)
2090-CCMCNDS-48AAxx Kinetix 3 control interface cable to MicroLogix controller 3 (9.8)
2090-DAIO-D50xxx Kinetix 3 control interface I/O cable (flying leads)
2090-U5PM-D09xx Ultra5000 drive to PanelView 300 Micro DF-1 terminal and MicroLogix system 1 (3.2)
3 (9.8)
2090-U5PV-D09xx Ultra5000 drive to PanelView Standard DF-1 terminal 9 (29.5)
SERCOS fiber optic plastic cables suitable only for in-cabinet duty. Connectors are
2090-SCEPx-x provided at both ends
0-1 (5.1 in.) (2) 3-0 (9.8) 15-0 (49.2)
2090-SCNPx-x SERCOS fiber optic plastic cables suitable for on-machine duty. Connectors are 0-2 (7.1 in.) (2) 5-0 (16.4) 20-0 (65.5)
provided at both ends 0-3 (1.0) (2) 8-0 (26.2) 25-0 (82.0)
1-0 (3.2) 10-0 (32.8) 32-0 (105.0)
SERCOS fiber optic plastic cables suitable for outdoor and conduit duty. Connectors
2090-SCVPx-x are provided at both ends
SERCOS fiber optic glass cables suitable for outdoor and conduit duty. Connectors 50-0 (164.2)
2090-SCVGx-x are provided at both ends 100-0 (328.3)
150-0 (492.5)
2090-S-BLHD SERCOS fiber optic cable bulkhead adapter (2 per pack) 200-0 (656.7)
1 (3.2)
0M3 = 0.3 (1.0)
Double-ended (shielded) Ethernet cables for use when programming the safety 2 (6.6)
1585J-M8CBJM-x 0M4 = 0.4 (1.3)
configuration and the Logix EtherNet/IP network module 5 (16.4)
0M6 = 0.6 (2.0) 10 (32.8)
2 (6.6)
Single-ended (shielded) Ethernet cables for use when programming the safety
1585J-M8CB-x 5 (16.4)
configuration and the Logix EtherNet/IP network module 10 (32.8)
1585J-M8CC-H RJ45 insulation displacement connector (IDC) for use when making your own cables 100 (328)
300 (984)
1585J-C8CB-Sxxx Shielded Ethernet (bulk) cable for use when making your own cables 600 (1968)
1202-C02 Drive-to-drive safety cable for connecting single-wide Kinetix 6000 axis modules 200 mm (7.9 in.)
1202-C03 Drive-to-drive safety cable for connecting double-wide Kinetix 6000 axis modules 350 mm (13.8 in.)
Drive-to-drive safety cable for connections between two Kinetix 6000 power rails,
1202-C10 1050 mm (41.3 in.)
two Kinetix 7000 drives, or from the Kinetix 6000 power rail to Kinetix 7000 drive
2090-XXNRB-10F0P5 10 AWG 0.5 (1.6)
Resistive Brake Module (RBM) to Kinetix 6000 and
Kinetix 6200/Kinetix 6500 drives
2090-XXNRB-8F0P6 8 AWG 0.6 (2.0)
2090-UXNRB-8F1P4 Resistive Brake Module (RBM) to Ultra3000 drives 8 AWG 1.4 (4.6)
(1) This cable does not carry the unbuffered motor encoder signals (CN1 pins 10-15). Contact your Allen-Bradley sales representative if these signals are required for your
application.
(2) Only available as 2090-SCEPx-x.
53.85
304.8 (2.12)
(12) 6.43
(0.25)
16.51 45°
(0.65) 33.32
(1.31)
2090-CCMDSDS-48AAxx
5.5 (drive-to-drive cable)
10.4 (0.22) 10.4
(0.41) (0.41)
2090-CCMCNDS-48AAxx
5.5 (controller-to-drive cable)
29.6 (0.22) 10.4
(1.2) (0.41)
15.1
(0.59) Dimensions are in mm (in.)
(reference only)
14.5
(0.57)
2090-CCMPCDS-23AAxx
5.5 (personal computer-to-drive cable)
(0.22) 10.4
(0.41)
37.1
60˚
(1.46)
14
(0.55)
11.4
35
(0.55)
(1.37)
Minimum Bend Radius = 64 (2.5)
55.1
(2.17)
Axis 0 - CN1
12.7
(0.5)
6.35
(0.25)
Axis 1 - CN1
11.94 Minimum Bend Radius = 119 (4.7)
(0.47)
Cable
55.5 Diameter
(2.2)
Start of
Bend Radius B Cable Diameter Connector
BR
Diameter
45˚ 33
(1.3) 23.9
(0.9)
16 28
(0.6) 5.9
(1.1) (0.2)
34
(1.3) 14 15
(0.5) (0.6)
34
(1.3)
34
(1.3)
15
(0.6)
34
(1.3)
RBM Drive
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering charts below to understand the configuration of your cables. For questions regarding product
availability, contact your Allen-Bradley distributor.
2090 - S C x x x-x
Cable Length
Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Cable Option
P = Plastic
G = Glass
Enclosure Option
E = Enclosure only
V = PVC jacket
N = Nylon jacket
Connector Option
C = Mating connectors (at both ends)
Type
S = SERCOS interface
Bulletin Number
2090 - C xx xx DS xx - AA xx
Cable Length
Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Cable Type
AA = Standard (non-flex)
Communication Method
23 = RS232 (with ASCII messaging)
48 = RS485 (with Modbus-RTU)
Blank = N/A
Connector Type (drive end of cable)
DS = Drive-side connector
Connector Type (other end of cable)
PC = DB-9-pin serial connector for personal computer connections
CN = 9-pin mini-DIN connector for MicroLogix 1100 or 1400 controller connections
DS = Drive-side connector
Cable Type
CM = Communication
S0 = Safe off
Accessory Component
C = Cable
Bulletin Number
2090 - xx xx - Dxx xx
Cable Length
Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Connector Type
D09 = 9-pin D-Shell
D44 = 44-pin, D-Shell
D50 = 50-pin, mini-D
Host
AE or CC= Ultra3000 to ControlLogix 1756-M02AE cable
PM = Ultra5000 to PanelView 300 MicroLogix DF-1
PV = Ultra5000 to standard PanelView DF-1
PC = Personal computer RS232/RS485 serial interface
Drive
U3 = Ultra3000
U5 = Ultra5000
UX = Ultra3000 or Ultra5000
DA = Kinetix 3
Bulletin Number
Use these examples to identify the best solution for wiring flying-lead feedback and I/O cables to servo drives or Line
Interface Modules (LIM).
In this example, the Kinetix 2000 (IAM/AM) is shown with catalog number 2090-K2CK-D15M, for use with the motor
feedback (MF) connector. Also shown is catalog number 2090-K2CK-COMBO for use with the motor feedback (MF)
and I/O (IOD/AF) connectors. Refer to Low-profile Connector Kit Components on page 443 for more information.
In this example, the Kinetix 6000 and Kinetix 7000 drives are shown with low-profile connector kits (catalog numbers
2090-K6CK-Dxxx). Use these kits with the I/O (IOD), motor feedback (MF), and auxiliary feedback (AF) connectors.
The 2090-K6CK-Dxxx kits also apply to the Kinetix 6200 and Kinetix 6500 drives. The Refer to Low-profile Connector
Kit Components on page 443 for more information.
Kinetix 6000, Kinetix 6200, Kinetix 6500, and Kinetix 7000 Low-profile Connector Examples
8.9 Dimensions are in mm (in.) 8.9
(0.35) (0.35)
2090-K6CK-Dxxxx
Low-profile Connector Kits
for IOD, MF, and AF Connectors
In this example, the LIM module is shown with low-profile connector kit (catalog number 2090-K6CK-D26M). Use this
connector with the I/O (IOL) connector on the 2094-AL09 and 2090-BL02 LIM modules. Refer to Low-profile
Connector Kit Components for more information.
2090-K6CK-D26M
Low-profile Connector
with LIM Module
(2094-AL09 is shown)
IOL Connector
IMPORTANT The flying-lead compatible cables listed below require connector kits to complete feedback and I/O connections to the
drive.
111
S 26 25 24 S 23 22 21 20 19 18 17 16 15 14 13
0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(4.3)
9 8 7 6 5 4 3 2 1
12 11 10
61
(2.4)
76
(3.0)
S1 ONLY
2 1
28 27 26 25 24 23 22 21 20 19 18 17 15 14 0
S0&S1 W/S0 DISABLED
4 3
AUX FEEDBACK
INPUTS
7 6 5
89
0 11 10 9 8
(3.5)
S1 ONLY
2090-K6CK-D44M Ø 11 (0.44) 21
(auxiliary feedback, safety, and I/O) (0.82)
44-pin Connector
R 6 (0.22) 12
(0.48)
This low-profile feedback module is designed for use with the Kinetix 6000 IAM/AM modules and Kinetix 7000 drives.
Cat. No. Description Cable Compatibility
2090-K6CK-KENDAT Low-profile feedback module (15-pin, male, D-sub) used to enable operation of drives with EnDat
feedback. Use with any Kinetix 6000 IAM/AM module and compatible motors with Endat encoders. 2090-XXNFMF-Sxx
2090-CFBM4DF-CDAFxx
2090-K7CK-KENDAT Low-profile feedback module (15-pin, male, D-sub) used to enable operation of drives with EnDat 2090-CFBM7DF-CDAFxx
feedback. Use with any Kinetix 7000 drive and compatible motors with Endat encoders.
111
(4.3)
13 12 11 10 9 8 7 6 5 4 3 2 1
61
(2.4)
2090-KxCK-KENDAT
15-pin Feedback Connector
20
(0.8)
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering charts below to understand the configuration of your component. For questions regarding product
availability, contact your Allen-Bradley distributor.
Use these examples to identify the best solution for wiring your flying-lead control interface, motor feedback, and serial
cables to Ultra3000, Ultra5000, and Kinetix 3 drives.
In this example, the Ultra3000/5000 drives are shown with drive-mounted breakout board kits (catalog number
2090-Uxxx-DMxx). Drive-mounted breakout board kits are available for the control interface (CN1), motor feedback
(CN2), and serial interface (CN3) connectors. Refer to Drive-mounted Breakout Board Components on page 448 for
more information.
54.1
(2.1)
66.1
Ultra3000 Ultra3000 (2.6) Ultra3000 Ultra3000
or or or or
Ultra5000 Ultra5000 Ultra5000 Ultra5000
Drive Drive Drive Drive
50.9
50.9 (2.0)
(2.0) Dimensions are in mm (in.)
TIP The 2090-UXBB-DM15 (feedback) kit is also compatible with the Kinetix 2000 IAM/AM, Kinetix 6000 IAM/AM, and
Kinetix 7000 drives (MF feedback connectors only).
In this example, the Kinetix 3 drives are shown with drive-mounted breakout boards (catalog numbers 2071-TBMF and
2071-TBIO). Use the 2071-TBMF breakout board with 2090-CFBM6DF-CBAAxx feedback cables or when your motor
or actuator has high-resolution encoder feedback. Use the 2071-TBIO breakout board for making flying-lead cable
connections to twenty-four of the most commonly used terminals in the 50-pin IOD connector. Refer to Drive-mounted
Breakout Board Components on page 448 for more information.
2071-TBMF
Drive-mounted Breakout Board
32.0 for MF Feedback Connector
(1.26)
Drive-mounted breakout boards are designed for use with Ultra3000, Ultra5000, and Kinetix 3 drives. Use this table to
identify the drive-mounted breakout board for your serial, I/O or feedback connector.
IMPORTANT The 2090-XXNFMF-Sxx and 2090-CFBMxDF-xxAxxx flying-lead feedback cables require connector kits to complete
feedback connections to the drive.
2090-U3BB2-DM44 (1) (2) 44-pin, drive-mounted breakout board for Ultra3000 CN1 control interface connector.
12-pin, drive-mounted breakout board for Ultra3000 CN1 connector recommended for use with SERCOS interface applications
2090-U3CBB-DM12 (3) with 24…5V auxiliary power converter.
2090-U3CBB-DM44 (3) 44-pin, drive-mounted breakout board for Ultra3000 CN1 connector with 24V to 5V auxiliary power converter.
2090-UXBB-DM15 (4) 15-pin, drive-mounted breakout board for Ultra3000/5000 CN2 feedback connector.
2090-UXBB-DM09 9-pin, drive-mounted breakout board for Ultra3000/5000 CN3 serial interface.
2071-TBIO 50-pin, drive-mounted breakout board for Kinetix 3 IOD I/O connector.
2071-TBMF 20-pin, drive-mounted breakout board for Kinetix 3 MF feedback connector.
(1) For specifications, refer to the CN1 Control Interface Breakout Boards Installation Instructions, publication 2090-IN007.
(2) This breakout board accepts 1.5 to 0.14 mm2 (16 to 26 AWG) wire. For applications that require a 44-pin drive-mounted breakout board that accepts 4 to 0.34 mm2
(12 to 22 AWG) wire, contact your local Allen-Bradley representative.
(3) Only for use with the Ultra3000 (2098-DSD-005x-xx, 2098-DSD-010x-xx, 2098-DSD-020x-xx) drives. Requires an external +24V DC power supply. For specifications, refer to
the CN1 Control Interface Breakout Boards with Integral 24V to 5V Auxiliary Power Converter Installation Instructions, publication 2090-IN008.
(4) For specifications, refer to the CN2 Motor Feedback Breakout Board Installation Instructions, publication 2090-IN006.
These (CN1) breakout boards apply to Ultra3000 drives (catalog numbers 2098-DSD-005, 2098-DSD-010, and
2098-DSD-020) in applications where 5V DC control power (if required) is user-supplied. The 12-pin board is intended
for use with SERCOS drives, but may be used in non-SERCOS applications with minimal I/O requirements.
IMPORTANT The 2090-U3BB-DMxx is required when wiring to the Ultra3000 (2098-DSD-030-SE/DN, 2098-DSD-075-SE/DN,
2098-DSD-150-SE/DN, or 2098-DSD-HVxxx-SE/DN) SERCOS/DeviceNet interface drives due to space restrictions
when connecting the SERCOS or DeviceNet interface cables.
65.4
(2.58)
2X 4-40 UNC
48.8
44-pin CN1 Connector 12-pin CN1 Connector (1.92) 21.8
(shown without cover) (shown without cover) Ø 12.7
(0.86)
2090-U3BB2-DM44 2090-U3BB-DM12 (0.50)
These (CN1) breakout boards apply to Ultra3000 drives (catalog numbers 2098-DSD-005, 2098-DSD-010, and
2098-DSD-020) in applications where a 24…5V DC converter for control power is required. The 12-pin board is intended
for use with SERCOS drives, but may be used in non-SERCOS applications with minimal I/O requirements.
IMPORTANT Do not use the 2090-U3CBB-DMxx when wiring to the Ultra3000 (2098-DSD-030-SE/DN, 2098-DSD-075-SE/DN,
2098-DSD-150-SE/DN, or 2098-DSD-HVxxx-SE/DN) drives.
84.6
(3.33)
2X 4-40 UNC
48.8
44-pin CN1 Connector 12-pin CN1 Connector Ø 12.7 (1.92) 21.8
(shown without cover) (shown without cover) (0.50) (0.86)
2090-U3CBB-DM44 2090-U3CBB-DM12
7.1 30.7
(0.2) (1.2)
8.6
(0.3) Front View
Connector End
Dimensions are in mm (in.) 5.08 2.3
(0.2) (0.09)
Ultra3000/5000 (CN3)
Breakout Board for 9-pin 1.5
Serial Connections (0.06)
4.5
(0.18)
9.4
Dimensions are in mm (in.) (0.37)
5.2 12.4
66.1
(0.21) (0.49)
(2.60)
35.5
(1.40)
21.8
2X 4-40 UNC
(0.86)
Connector shown without cover. Connector shown with cover.
Ultra3000/5000 (CN2)
Ø 11.4 Breakout Board for 15-pin
(0.45) Motor Feedback Connections
Kinetix 3 (IOD)
2071-TBIO Breakout Board for 52.0
50-pin Control Interface Connections (2.05)
70.0
Kinetix 3 (MF) (2.75)
2071-TBMF Breakout Board for
20-pin Motor Feedback Connections
48.0
(1.89)
18.0
(0.71)
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering charts below to understand the configuration of your component. For questions regarding product
availability, contact your Allen-Bradley distributor.
Panel-mounted breakout board kits for motor feedback (catalog number 2090-UXBK-D15xx) and control interface
(catalog number 2090-U3BK-D44xx) are designed for use with Ultra3000, Ultra5000, Kinetix 300, Kinetix 2000,
Kinetix 6000, Kinetix 6200, Kinetix 6500, and Kinetix 7000 drives. Refer to Panel-mounted Breakout Board Components
on page 452 for more information.
44-pin
(IOD/AF) Control Wire Terminations
Interface
44-pin 2090-UXBB-D15
(CN1) Panel-mounted
2090-UXBC-D15xx Breakout Board
Breakout Cable
Breakout boards, cables, and kits (designed for DIN rail mounting on the panel) and for use with Ultra3000/5000,
Kinetix 2000, Kinetix 6000, and Kinetix 7000 drives are shown below. These breakout board components can be ordered
separately, or as a kit containing both terminal block and cable.
IMPORTANT The flying-lead compatible cables listed above require either 2090-UXBB-DM15 (drive-mounted) or 2090-UXBB-D15
(panel-mounted) breakout board connector kits to complete feedback and I/O connections to the drive.
87.1
Side View
(3.4) Front View
56.6
69.8
(2.2)
(2.7)
29.1
(1.1)
Bottom View
49.63
(1.954)
Dimensions are in mm (in.)
87.12
Side View (3.43) Front View
69.85
125.98 (4.96)
(2.75)
62.3 (2.48)
Bottom View
41.7 (1.6)
33.5 (1.3)
19.05
Dimensions are in mm (in.) (0.75)
19.05 59.13
(0.75) (2.3)
44.45
10.9 (0.43) (1.75)
45º 0.6
(15.9)
70.2 (2.7)
Specifications
Standard Cable Lengths
Breakout Cable Description Rating Jacket m (ft)
Shield Coverage
° C (° F) Material
15-pin, high density D-shell for Kinetix 6000
2090-UXBC-D15xx motor/auxiliary feedback and 1 (3.2)
100% Aluminum Foil
Ultra3000/5000 CN2 feedback connector 3 (9.8)
90 ° C (194 ° F) (with 85% braid TPE 9 (29.5)
44-pin, high density D-shell for Ultra3000 overshield)
2090-U3BC-D44xx 15 (49.2)
CN1 control interface connector
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering charts below to understand the configuration of your component. For questions regarding product
availability, contact your Allen-Bradley distributor.
2090 - xx xx - Dxx xx
Length
Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Blank = N/A
Connector Type
D44 = 44-pin, male, D-sub, 44 connections
D15 = 15-pin, male, D-sub, 15 connections
Kit Type
BK = Breakout board and cable kit
BC = Breakout cable only
BB = Breakout board only
Drive
UX = Kinetix 300, Kinetix 2000, Kinetix 6000, Kinetix 6200, Kinetix 6500, Kinetix 7000,
Ultra3000, and Ultra5000 drives
U3 = Ultra3000 or Kinetix 2000 drives
Bulletin Number
Converter Inverter
Shunt Module Cat. No. Slot Used Slots Used
230/
2094-BSP2 0 1
460V
Integrated axis modules (2094-AC32-M05-S, 2094-BC04-M03-x, and 2094-BC07-M05-x) and axis modules
(2094-BM03-x and 2094-BM05-x) are double-wide modules and require two slots on the power rail.
The leftmost slot on each power rail is the converter slot and only used by the IAM module. All other slots are inverter slots
and are used by the IAM, AM, or shunt module (refer to the figure below). The power rail catalog number indicates the
number of available inverter slots.
For example, the 2094-PRS1 power rail contains one inverter slot. This limits the use of this power rail to systems requiring
only one inverter slot. Similarly, the 2094-PRS8 power rail contains eight inverter slots. This limits the use of this power rail
to systems requiring up to eight inverter slots.
When selecting a power rail, determine the number of inverter slots required by all rail-mounted modules and choose a
power rail with that minimum number of inverter slots.
IMPORTANT If you select a power rail with slots exceeding the minimum required for your system, you must install a 2094-PRF
slot-filler module in each unused slot.
2094-PRS8
Power Rail
Converter Slot
Protective Cover
(typical)
TIP The Bulletin 2094 power rails ship with a protective cover over the converter and inverter slot pins.
134.6
(5.3)
22.9
(0.90) 88.9 25.4
(3.5) (1.0)
Ø 7.95
(O.313) TYP.
231 35.1
Dimensions are in mm (in.)
(9.1) (1.4)
190.5
(7.5)
12.4
(0.50)
69.9
(2.75)
Dimensions (catalog numbers 2094-PRS2, 2094-PRS3, 2094-PRS4, 2094-PRS5, 2094-PRS6, 2094-PRS7, and 2094-PRS8)
22.9 A
(0.90) B
C 25.4
Dimensions are in mm (in.) (1.0)
231 35.1
(9.1) (1.4)
190.5
(7.5)
12.4
(0.50)
Ø 7.95
(O.313) TYP.
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your power rail. For questions regarding product
availability, contact your Allen-Bradley distributor.
2094 - PRS x
Module Capacity
1 = IAM and no additional modules
2 = IAM and up to 1 additional module
3 = IAM and up to 2 additional modules
4 = IAM and up to 3 additional modules
5 = IAM and up to 4 additional modules
6 = IAM and up to 5 additional modules
7 = IAM and up to 6 additional modules
8 = IAM and up to 7 additional modules
Power Rail
PRS = Power Rail, available in 1, 2, 3, 4, 5, 6, 7, and 8 axis capacity
Bulletin Number
IMPORTANT The 2094-BSP2 shunt module is compatible with all 230V and 460V systems, however, the 2094-BSP2 shunt module is
physically larger than the 230V drives and additional clearance is required beneath and in front of the module.
The table below lists the power specifications for the Bulletin 2094 shunt module. Refer to page 460 for tables with the
Bulletin 2094 shunt module in combination with an IAM module internal shunt (when present) and the various external
passive shunt resistors available for 230V and 460V drive systems. Use these tables to determine the combination you need
based on the requirements of your application.
Specifications
Short Circuit
Shunt Module Drive Peak Peak Continuous Current Rating Fuse
Cat. No. Voltage Resistance Power Current Power Capacitance Replacement
A
V AC Ω kW A W μF
230 5.7 14 200,000 N/A
2094-BSP2 28.75 200 470
460 22.5 28 symmetrical (no internal fuse)
For specifications and dimensions of external shunt resistors compatible with your Kinetix 6000 or Kinetix 6200 drive,
refer to External Shunt Modules beginning on page 494.
In this table, the 230V system specifications are given for the IAM module internal shunt resistors, the 2094-BSP2 shunt
module, and the Bulletin 1394 external shunt modules.
Specifications System
IAM Module Number of Shunt Continuous
Cat. No. Axis Modules Peak Peak Continuous External Passive
Module Resistance Shunt Module (1) Shunt Power
2094- Qty Cat. No. Current Power Power
Ω W
A kW W
AC05-MP5-S – – – – 0
AC05-M01-S – – – – 0
(2)
AC09-M02-S 0 to 7 N/A (2) – – – – N/A 50 (3)
AC16-M03-S – – – –
200 plus (4)
AC32-M05-S – – – –
ACxx-Mxx-S 0 to 6 2094-BSP2 28.75 14.1 5.7 200 N/A (2) 200 plus (5)
ACxx-Mxx-S 300 1394-SR9A 300 (6)
ACxx-Mxx-S 900 1394-SR9AF 900 (6)
0 to 6 2094-BSP2 4 101.3 41
ACxx-Mxx-S 1800 1394-SR36A 1800 (6)
ACxx-Mxx-S 3600 1394-SR36AF 3600 (6)
(1) Refer to External Shunt Modules beginning on page 494 for shunt module specifications.
(2) Module not part of system configuration.
(3) Shunt power equals 50 or the sum of the AM module internal shunt ratings.
(4) Shunt power equals 200 plus the sum of the AM module internal shunt ratings.
(5) Shunt power equals 200 plus the sum of the IAM module (2094-AC16-M03-S and 2094-AC32-M05-S only) and AM module internal shunt ratings.
(6) Use of external shunt module disables internal IAM/AM shunt modules.
IMPORTANT Use of the 2094-BSP2 shunt module in combination with the 2094-AC09-M02-S IAM module disables the shunt
resistor internal to that IAM module. This situation is unique to the 2094-AC09-M02-S IAM module. Shunt resistors
internal to adjacent AM modules are not disabled. Refer to the 230V Shunt Power Example (catalog number
2094-AC09-M02-S) shown below.
In this example, the continuous shunt power is 300 W. The 50 W resistor in the IAM module is disabled when used in
combination with the 2094-BSP2 shunt module. This example is unique to the 2094-AC09-M02-S IAM module.
In this table, the 460V system specifications are given for the IAM module internal shunt resistors, the 2094-BSP2 shunt
module, and the Bulletin 1394 external shunt modules.
Specifications System
IAM Module Number of Shunt External
Peak Peak Continuous Continuous
Cat. No. Axis Modules Module Resistance Passive Shunt Power
2094- Qty Cat. No. Current Power Power Shunt Module (1)
Ω W
A kW W
BC01-MP5-S – – – – 50 plus (3)
BC01-MP5-M
BC01-M01-S – – – – 50 plus (3)
BC01-M01-M
BC02-M02-S N/A (2)
0 to 7 N/A (2) – – – – 50 plus (3)
BC02-M02-M
BC04-M03-S – – – –
BC04-M03-M
200 plus (4)
BC07-M05-S – – – –
BC07-M05-M
BCxx-Mxx-x 1 to 6 2094-BSP2 28.75 28 22.5 200 N/A (2) 200 plus (5)
BCxx-Mxx-x 300 1394-SR9A 300 (6)
BCxx-Mxx-x 900 1394-SR9AF 900 (6)
1 to 6 2094-BSP2 4 201.3 162
BCxx-Mxx-x 1800 1394-SR36A 1800 (6)
BCxx-Mxx-x 3600 1394-SR36AF 3600 (6)
(1) Refer to External Shunt Modules beginning on page 494 for shunt module specifications.
(2) Module not part of system configuration.
(3) Shunt power equals 50 or the sum of the AM module internal shunt ratings.
(4) Shunt power equals 200 plus the sum of the AM module internal shunt ratings.
(5) Shunt power equals 200 plus the sum of the IAM and AM module internal shunt ratings.
(6) Use of external shunt module disables internal IAM/AM shunt modules.
In this example, the sum of the IAM, AM, and shunt modules equal 500 W of continuous shunt power. Although a 230V
system is shown, a 460V IAM, AM, and shunt module power adds up the same way.
Shunt Power Example for (230V) Kinetix 6000 Drives (without external shunt)
In this example, the sum of the IAM/AM modules and shunt module equal 400 W of continuous shunt power.
TIP Shunt power adds up the same way for 230V (IAM/AM, and shunt module) systems too.
Shunt Power Example for Kinetix 6000 Drives (without external shunt)
Shunt Power Example for Kinetix 6200 or Kinetix 6500 Drives (without external shunt)
IMPORTANT When the 2094-BSP2 shunt module is wired to a Bulletin 1394 external shunt module, the IAM/AM (internal shunt) and
2094-BSP2 shunt module is disabled and the continuous shunt power is equal to that of the external shunt module alone.
287
(11.3)
2094-BSP2
Shunt Module
256
(10.1)
Power Rail
Modules are shown mounted to the power rail and the dimensions reflect that.
1
1 2 3
2
INT
DC+
5 Item Description
6
TS2
1 Motor cable shield clamp
1 2
TS1 3 7
For replacement connector set catalog number, refer to Connector Sets on page 465.
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your module. For questions regarding product
availability, contact your Allen-Bradley distributor.
2094 - BSP2
Input Voltage/kW Rating
BSP2 = 230/460V input voltage, 200 W
Bulletin Number
IMPORTANT The 2094-PRF slot-filler module is compatible with all 230V and 460V systems. Power rail slots not occupied by an
IAM, AM, or shunt module, must have a slot-filler module installed.
2094-PRF
Slot-filler Module
206
8.2
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your module. For questions regarding product
availability, contact your Allen-Bradley distributor.
2094 - PRF
Power Rail Filler
Bulletin Number
Connector Sets
Kinetix 6000, Kinetix 6200, Kinetix 6500 Drive Families
You can implement the safe-off function in a single drive or extend it to as many as eight drives in a multiple safety drive
configuration. The safe-off connector can also be jumpered to effectively remove the safe-off function (this is the default
setting). For more information on wiring safe-off connections, refer to the Kinetix Safe-off Feature Safety Reference
Manual, publication GMC-RM002.
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
In this example, system 1 contains two (single-wide) Kinetix 6000 drives using the safe-off feature wired with two
(double-wide) Kinetix 6000 drives in system 2. The wiring headers with motion allowed jumpers have been replaced as
shown. The third axis in system 1 does not use the safe-off feature, so the wiring header and motion allowed jumper remain
installed.
This multiple drive configuration also applies to the Kinetix 7000 drives. When wiring the Kinetix 7000 modules from
drive-to-drive, use 1202-C10 cables.
2090-XNSM-T
Last-drive Header
2090-XNSM-W
First-drive Wiring Header
1 2 3 4 5 6 7 8 9
IMPORTANT Due to the current capacity limitation of the safe-off cable connectors, multiple safe-off drive configurations must not
exceed eight Kinetix 6000 or Kinetix 7000 drive modules.
Safe-off Components
Description Cat. No.
Safe-off wiring header for the first drive in multiple safety drive configurations. 2090-XNSM-W
Safe-off middle header for drive-to-drive connections in multiple safety drive configurations with three or more drives. 2090-XNSM-M
Safe-off terminating header for the last drive in multiple safety drive configurations. 2090-XNSM-T
Drive-to-drive safety cable for connecting single-wide Kinetix 6000 drives. 1202-C02
Drive-to-drive safety cable for connecting double-wide Kinetix 6000 drives. 1202-C03
Drive-to-drive safety cable for connections between two Kinetix 6000 power rails, two Kinetix 7000 drives, or from the 1202-C10
Kinetix 6000 power rail to Kinetix 7000 drive.
137
(5.4)
2090-K2KSCLAMP-4
Cable Clamp Bracket Kit
for Motor Power Cable
(top mount)
Power
Rail
Kinetix 2000 Kinetix 2000
Integrated Axis Modules Kinetix 2000 Axis Modules
2093-AC05-MP1 Axis Modules 2093-AMP1
2093-AC05-MP2 2093-AM01 2093-AMP2
Dimensions are in mm (in.) 2093-AC05-MP5 2093-AM02 2093-AMP5
2090-K2KSCLAMP-4
Power
Cable Clamp Bracket Kit
Rail
for Motor Power Cable
(bottom mount)
77 77 77
(3.0) (3.0) (3.0)
Each bracket provides threaded holes for mounting the 2094 power rail or LIM (catalog numbers 2094-ALxxS and
2094-XL75S-Cx). The number of brackets required for use with the power rail and LIM are shown in the table below.
Module to Mount Brackets Required
LIM (2094-ALxxS and -XL75S-Cx) 2
Power Rail (PRSx) 1-4 axis 2
Power Rail (PRSx) 5-8 axis 3
IMPORTANT The 2094-BLxxS, 2094-AL09, and 2094-BL02 LIM models are not compatible with the 2094 mounting brackets.
PR/PRS
301 ±0.5
(11.86 ±0.020)
PR
PRS
LIM
Ground
Stud
76.2 89.3 ±0.5
(3.0) (3.51 ±0.020)
In the figure below, the power rail (catalog number 2094-PRSx) is shown mounted on Bulletin 2094 Mounting Brackets.
LIM
LIM
LIM
PR/PRS PR/PRS PR/PRS
Power Rail
(2094-PRS8 is shown)
LIM
LIM
Mounting Brackets
(2094-XNBRKT-1)
In the figure below, the LIM module (catalog numbers 2094-ALxxS or 2094-XL75S-Cx) is shown mounted on Bulletin
2094 Mounting Brackets.
Mounting Bracket
PRS
PR
PR
LIM LIM
352.4
(13.87) MAIN VAC
Mounting Bracket
PRS
PR
PR
LIM LIM
(2094-XNBRKT-1)
IMPORTANT Only the 2094-ALxxS and 2094-XL75S-Cx Line Interface Modules are compatible with the 2094 Mounting Brackets.
The 2094-BLxxS, 2094-AL09, and 2094-BL02 models are not compatible.
Bulletin 842HR sine/cosine encoders combine the advantages of incremental and absolute encoder technologies in a single,
standalone unit targeted for high-performance digital servo drive systems. The Bulletin 842HR is a 15-bit encoder
featuring a hybrid digital/analog interface, transmitting sine/cosine signals via analog channels for incremental feedback
and delivering absolute position information through the digital RS-485 channel.
Refer to 842HR Sine Cosine/Serial Encoders catalog, publication C116-CA600, for more information.
Bulletin 844D through-shaft incremental encoders are used to electronically monitor the position or speed of a rotating
shaft. Shaft position is converted to digital pulses in an A quad B format. A Zero Index Channel is also included with all
models.
Refer to 844D Hollow Shaft Incremental Encoders catalog, publication 844D-CA500, for more information.
The Bulletin 845H optical incremental encoders electronically digitize shaft motion of a rotating element by converting
mechanical motion to an electronic digital format. Incremental square waves are accumulated in a counter as position
feedback. The encoder provides code disk resolutions up to 5000 pulses per revolution at a signal frequency response of
210 kHz.
The Bulletin 845H encoder is housed in a size 25, NEMA Type 4 and 13, IP66 (IEC 529), enclosure making it suitable for
many of today’s industrial environments.
Refer to 845H Size 25 Incremental Encoders catalog, publication 845H-CA500, for more information.
Bulletin 845T optical incremental encoders are used to electronically monitor the position of a rotating shaft. Shaft motion
is converted to digital pulses that are accumulated and evaluated by various electronic controllers. The Bulletin 845T
encoder provides code disk resolutions of up to 3000 pulses per revolution, and a frequency response of up to 100 kHz.
The Bulletin 845T encoder is a heavy duty, NEMA Type 4, and IP66 (IEC 529) rated optical incremental shaft encoder
that is housed in a two inch diameter enclosure. Typical applications for the 845T include machine tools, packaging
machinery, motion controls, and robotics. The heavy duty bearing assembly, rugged construction and high shaft loading
capabilities make the Bulletin 845T encoder suitable for many of today’s harsh industrial environments.
Refer to 845T Size 20 Incremental Encoders catalog, publication 845T-CA500, for more information.
Comparing the LIM Module with Discrete Components (catalog number 2094-BLxxS)
Three-phase Three-phase
Line Input (460V) Line Input (460V)
Contactor
Components require Control and
Circuit Breaker more time for: Fuse Block Disconnect Status I/O
(CB3)
• Panel Layout/Design Line Interface Module
MAIN VAC
Auxiliary I/O Auxiliary Control Three-phase Auxiliary I/O Auxiliary Control Three-phase
Power Output Power Output Power Output Power Output Power Output Power Output Power Output Power Output Power Output Power Output
(24V DC) to: (24V DC) to: (230V) to: to Drive to Drive (24V DC) to: (24V DC) to: (230V) to: to Drive to Drive
Motor Brake Sensors PLC (230V AC) (460V AC) Motor Brake Sensors PLC (230V AC) (460V AC)
other PLC HMI other PLC HMI
other other AC Line other other AC Line
Filter Filter
SERCOS interfaceTM
SERCOS interfaceTM
CP OK
CP OK
Tx (rear)
Tx (rear)
Rx (front)
Rx (front)
MP-Series Photoelectric ControlLogix PanelView Plus Kinetix 6000, Kinetix 6200, MP-Series Photoelectric ControlLogix PanelView Plus Kinetix 6000, Kinetix 6200,
Motor Sensors Chassis Terminal Kinetix 6500, or Kinetix 7000 Drive Motor Sensors Chassis Terminal Kinetix 6500, or Kinetix 7000 Drives
An example comparing the 2094-ALxxS module to discrete components would be similar to the example above, but with
230V three-phase input power and without the 460V to 230V step-down transformer.
Examples comparing the 2094-AL09 and 2094-BL02 modules to discrete components would also be similar to the
examples above and include the features that apply to those models.
Drive Family Drive Cat. No. Compatible LIM Module Cat. No.
Kinetix 2000 2093-AC05-Mxx 2094-ALxxS, 2094-XL75S-C2, 2094-AL09
Kinetix 6200/ 2094-BCxx-Mxx-M 2094-BLxxS, 2094-BL02, 2094-XL75S-Cx
Kinetix 6500
Kinetix 6000 2094-xCxx-Mxx-S 2094-ALxxS, 2094-AL09, 2094-BLxxS, 2094-BL02, 2094-XL75S-Cx
Kinetix 7000 2099-BM06-S, 2099-BM07-S, 2099-BM08-S 2094-BL75S
In this example, the 2094-XL75S-C1 and 2094-XL75S-C2 modules are compared to a similar configuration of discrete
components. Both of these units provide a connector for an external (customer-supplied) auxiliary and control power
input. The 2094-XL75S-C1 module is designed for 110V auxiliary and control power input/output. The 2094-XL75S-C2
module is designed for 230V auxiliary and control power input/output.
Comparing the LIM Module with Discrete Components (catalog number 2094-XL75S-Cx)
Contactor
Components require Control and
Circuit Breaker Status I/O
(CB3)
more time for: Fuse Block Disconnect
Auxiliary I/O Auxiliary Control Three-phase Auxiliary I/O Auxiliary Control Three-phase
Power Output Power Output Power Output Power Output Power Output Power Output Power Output Power Output Power Output Power Output
(24V DC) to: (24V DC) to: (110/230V) to: to Drive to Drive (24V DC) to: (24V DC) to: (110/230V) to: to Drive to Drive
Motor Brake Sensors PLC (110/230V AC) (230/460V AC) Motor Brake Sensors PLC (110/230V AC) (230/460V AC)
other PLC HMI other PLC HMI
other other AC Line other other AC Line
Filter Filter
SERCOS interfaceTM
SERCOS interfaceTM
CP OK
CP OK
Tx (rear)
Tx (rear)
Rx (front)
Rx (front)
MP-Series Photoelectric ControlLogix PanelView Plus Kinetix 2000, Kinetix 6000, MP-Series Photoelectric ControlLogix PanelView Plus Kinetix 2000, Kinetix 6000,
Motor Sensors Chassis Terminal Kinetix 6200, or Kinetix 6500 drives Motor Sensors Chassis Terminal Kinetix 6200, or Kinetix 6500 Drives
Branch circuit protection for the 2094-ALxxS and 2094-BLxxS modules is customer configurable. By moving the
CB2/CB3 wiring harness (P4) from one side of CB1 to the other, you can change the module operation. To understand
this option, refer to the simplified block diagram below.
Three-phase
Input (OPL)
Aux Power I/O Power Aux Power Control Power Three-phase Power
Output (P1L) Output (IOL) Output (P2L) Output (CPL) Output (OPL)
24V DC 24V DC 230V AC 230V AC to Drive
Features
Features available with the Line Interface Module (LIM) include the following:
• Power production for drive, motor brakes, and auxiliary use.
– Branch circuit protection and disconnect for three-phase power is provided by an Allen-Bradley Bulletin 140U
molded case circuit breaker. The 140U includes both magnetic and thermal protection, eliminating the need for
fuses on the three-phase line. Variable Depth Rotary Mechanism (140U-H-RM12B) is required for disconnect
feature.
– Customer configurable branch circuit protection (catalog numbers 2094-ALxxS and 2094-BLxxS) provides the
option of using the Bulletin 140U circuit breaker to control all output power (optional) or only three-phase
output power (default).
– Three-phase (230V or 460V) output power to drive controlled by a safety power contactor.
– 24V DC supply rated at 20 A (catalog numbers 2094-ALxxS, 2094-BLxxS, and 2094-XL75S-Cx) or 8 A (catalog
numbers 2094-AL09 and 2094-BL02).
– Single-phase auxiliary power and control power sourced from internal three-phase input power or external
(customer-supplied) input power supply.
• Provides power to single or multiple Kinetix 2000 or Kinetix 6000 power rails. Cumulative IAM input current must
not exceed LIM module output current (applies to catalog numbers 2094-ALxxS, 2094-BLxxS, and
2094-XL75S-Cx only).
• Internal line filter (catalog numbers 2094-AL09 and 2094-BL02). External (customer-supplied) line filter (catalog
numbers 2094-ALxxS, 2094-BLxxS, and 2094-XL75S-Cx).
• 2094 mounting bracket compatibility for additional panel space saving. Using mounting brackets (catalog number
2094-XNBRKT-1) in your system (2094-ALxxS and 2094-XL75S-Cx modules only) lets you mount the AC line
filter behind the LIM module. Refer to Bulletin 2094 Mounting Brackets on page 469 for specifications.
• Plugable connectors let you remove and replace each connector for easy wiring.
This table provides a summary of the features available with each Line Interface Module. Use this table and Line Interface
Module Selection Flowchart on page 477 to select a LIM module for your drive system.
Line Interface Module Cat. No.
Features
2094-ALxxS 2094-BLxxS 2094-XL75S-C1 2094-XL75S-C2 2094-AL09 2094-BL02
Input Power 230V 460V 230V or 460V 230V 460V
Auxiliary and Control Power Input N/A N/A
(customer-supplied)
110V 230V
Auxiliary Power Output 230V (1) N/A
Control Power Output 230V 230V
24V DC Power Output Current 20 A 8A
Capacity
Configurable Branch Circuit No No
Protection
Branch Circuit Protection and
Disconnect Yes
Yes No No
Power to Multiple Power Rails (2) Yes Yes
DC Line Filter
Mounting Bracket Compatibility No
AC Line Filter External (customer-supplied) Internal Internal
Auxiliary/Control Power Line Filter Yes
(1) Auxiliary power output developed internal to LIM module.
(2) For more information on powering multiple power rails from one Line Interface Module, refer to Rockwell Automation technical support.
Use this flowchart to select a LIM module for your drive system based on the input voltage and features you need.
230V 460V
230V or 460V
Input Power?
Separate (external)
Customer-supplied
Yes Source Yes
Auxiliary Power Input Auxiliary AC input voltage 93…121V rms single-phase (110V nom) 196…253V rms single-phase (230V nom)
(APL) Connector Auxiliary AC input current (rms) 20 A 11 A
Control Power Output AC output current (rms) 12 A 5A
(CPL) Connector
and
Auxiliary Power Output AC output voltage 93…121V rms single-phase (110V nom) 196…253V rms single-phase (230V nom)
(P2L) Connector
Brake Power Output
(P1L) Connector 24V DC Power Supply 20 A
and
I/O (IOL) Connector
Contactor control voltage (1) 21.6…26.4V DC
Contactor control current (1) 12…9 mA
VAC Line AC input voltage 195-265V rms three-phase (230V nom) 380-520V rms three-phase (460V nom)
(IPL) Connector AC input frequency 47…63 Hz
VAC Load Main AC output current 20 A rms 30 A rms
(OPL) Connector
259.8
(10.23)
CONTROL VAC
CTRL2
CTRL1
195-265 VAC LINE, 50/60 Hz
AUX2
AUX1
L1
Dimensions are in mm (in.)
2094-XL75S-Cx is shown
195-265 VAC LOAD, 50/60 Hz
I/O_COM
24 VDC SUPPLY
I/O_PWR
I/O_COM
L3' I/O_PWR
I/O_COM
I/O_PWR
L2'
L1'
(14.80)
2x 352.4 309.9
309.9 (13.87) (12.20)
(12.20)
2x 33 (1.30) 220
(8.66)
Dimension A
Cat. No.
mm (in.)
2094-ALxxS
198.3 (7.81)
2094-XL75S-Cx
2094-BLxxS 248.0 (9.76)
325
(12.8)
184.7 187.7
(7.27) (7.39)
197
(7.75)
3x Ø 16 6x Ø 7.9 12.7 22
(0.63) (0.31) 187.7
(0.5) (0.87)
(7.39)
3x 28.7 (1.13)
8.9
225 (0.35)
(8.86)
253.1
(9.97)
286.8
(11.29)
28
30.9 142.5 12.7 (1.1)
(1.22) (5.61) (0.5)
20 285 Flying Lead I/O Cable with 2090-K6CK-D26Mxx
(0.79) (11.22) Low-profile Connector Kit
400
(15.75)
100
(3.9)
2x 206
(8.11) Dimensions are in mm (in.)
280
(11.02)
277
(10.9)
2x 28.5 (1.2)
2x 40.4 27.6
280 (1.59) (1.09)
(11.02)
3x Ø 16 6x Ø 7.9
(0.63) (0.31) 289
12.7
(11.37)
(0.50)
3x 28.7 (1.13)
8.9
(0.35)
252.2
(9.93)
312
(12.28) 197 IMPORTANT: Additional clearance
278.4 below the connector is necessary to
(7.8) 250 (10.96) provide the recommended cable bend
(9.84) radius.
1 2
L2N
L1
CONTROL VAC
1 2
CTRL2
CTRL1 8
1 2 3 4
AUX2
6 L2
AUX2
3
AUX1
AUX1
L1
12 3 4 5 6
I/O_COM
195-265 VAC LOAD, 50/60 Hz
24 VDC SUPPLY
I/O_PWR
1 I/O_COM
10
I/O_PWR
2
L3'
5 I/O_COM
I/O_PWR
3
L2'
L1'
Line Interface Module
4
11
12
4
OFF
CB1 13
ON
MAIN VAC
IOL Connector
(viewed from side)
3
2
1
For replacement connector set catalog numbers, refer to Connector Sets on page 465.
1 2
L1
L2/N
Item Description
1
PE PE
1 2 3 4
1 2 3 4
50/60 Hz
50/60 Hz
L3 MBRK PWR L3
7
4321
L2 MBRK COM
MBRK PWR
L2 1 9 1 CB3 - Brake and I/O VAC
L1 MBRK COM L1 1
4
3 2 1
Line Interface Module
(2094-AL09 front view is shown)
For I/O connector kit, refer to Low-profile Connector Kit Components on page 443.
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your module. For questions regarding product
availability, contact your Allen-Bradley distributor.
2094 - x L xxx - Cx
Features
AL09 = 20 A, 24V DC @ 8 A, internal three-phase line filter
BL02 = 30 A, 24V DC @ 8 A, internal three-phase line filter
AL15S = 15 A, 230V AC auxiliary power output, 24V DC @ 20 A, configurable branch circuit protection
BL10S = 10 A, 230V AC auxiliary power output, 24V DC @ 20 A, configurable branch circuit protection
AL/BL25S = 25 A, 230V AC auxiliary power output, 24V DC @ 20 A, configurable branch circuit protection
AL/BL50S = 50 A, 230V AC auxiliary power output, 24V DC @ 20 A, configurable branch circuit protection
AL/BL75S = 75 A, 230V AC auxiliary power output, 24V DC @ 20 A, configurable branch circuit protection
XL75S-C1 = 75 A, Input for 110V AC (customer-supplied) auxiliary power, 24V DC @ 20 A
XL75S-C2 = 75 A, Input for 230V AC (customer-supplied) auxiliary power, 24V DC @ 20 A
Module Input Voltage
AL = 230V AC, 50/60 Hz
BL = 460V AC, 50/60 Hz
XL = 230/460V AC, 50/60 Hz
Bulletin Number
AC Line Filters
This section contains AC line filter selection tables, specification tables, and dimension drawings. Use the tables below to
match an AC line filter to your servo drive.
25
(1.0)
Line C Load I
25
Detail A (1.0)
D
E J
Nut (2) PCB Board
F Ø 7 (0.27)
H (2) M6 studs required
G for side mounting. Plain Washer (2)
Detail A
M5 Stud Set
(earth terminals are M5)
A B C D E F G H I J
Cat. No.
mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
9.0 152.0 55.0 18.0 170.0 9.0 10.0 152.0 92.0 25.0
2090-UXLF-106 (0.35) (5.99) (2.17) (0.71) (6.69) (0.35) (0.39) (5.99) (3.62) (0.98)
104.0 16.0 145.0 40.0
2090-UXLF-110 (4.0) (0.63) (5.71) (1.58)
2090-UXLF-123 11.0 192.0 20.0 214.0 11.0 192.0
(0.43) (7.56) 164.0 (0.79) (8.42) (0.43) 19.0 (7.56) 204 47.0
2090-UXLF-132 (6.46) (0.75) (8.04) (1.85)
2090-UXLF-HV323
Detail A
174
(6.8) 120
20 (4.7)
(0.79)
L1 L1' Detail A
113
120
Detail A (4.4)
(4.7)
25
25 (0.9) 25
110 (0.9) (0.9)
(4.3)
22
(0.9)
55
(2.2)
230 147
(9.0) (5.8)
L3 L3'
D
L2 L2'
Load
G
Line
L1 L1'
E E'
Detail A
C H
A B C D E F G H
Cat. No.
mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
11.0 338 145 29.5 16.0 204 40.0
2090-UXLF-HV330 (0.4) (13.3) 360 (5.7) (1.1) (0.63) (8.0) (1.6)
15.0 330 (14.2) 155 20.0 32.5 195 65.0
2090-XXLF-X330B (0.6) (13.0) (6.1) (0.8) (1.3) (7.7) (2.5)
L3 L3'
L2 L2'
F
Line
Load
L1 L1'
E E'
A E
B Nylon
Nut (2)
Bushing
G H
Washer (3)
I Detail A
J
M6 Stud Set
(earth terminals are M8)
A B C D E F G H I J K
Cat. No.
mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
578 618 160 230 578
2090-UXLF-HV350 (22.7) (24.3) (6.3) 35 20 (9.0) (22.7) 35 70 20
2090-XXLF-375 646 686 192 (1.4) (0.8) 262 646 15 (1.4) (2.7) (0.8)
2090-XXLF-375B (25.4) (27.0) (7.5) (10.3) (25.4) (0.6)
741 785 215 30 21.5 275 741 47 80 18
2090-XXLF-3100 (29.2) (30.9) (8.4) (1.2) (0.85) (10.8) (29.2) (1.8) (3.1) (0.7)
C
H
J
TYP
AA
D B Dimensions are in mm (in.)
E
A
A B C D E F G H I J K
Cat. No.
mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
230 50 25 215 200 12
2090-XXLF-TC316 (9.0) (1.96) (0.98) (8.46) (7.87) (0.47)
80 1.0 5.5 15
M6x25
2090-XXLF-TC350 180 85 (3.15) 65 164 150 39 (0.04) (0.21) (0.59)
2090-XXLF-TC365 (7.08) (3.35) (2.56) (6.45) (5.90) (1.53)
37 (1.4)
90
(3.54)
96 200
(3.8) 37 (1.4) (7.8)
2x 285
(11.2) 43.5 (1.7)
Ø 4x 11
(0.43)
52 (2.0)
2x 165
Dimensions are in mm (in.)
(6.5)
52 (2.0)
M10 x 30
43.5 (1.7)
310
(12.2)
80
(3.15)
M6x25
1.0
(0.04) 15
(0.59)
5.5
(0.21)
L1' Load N'
TYP
L1 PE N
25 50
Line
(0.98) (1.96)
215
(8.46)
230
(9.0)
65
(2.5)
6.5
(0.25)
364
(14.3) Dimensions are in mm (in.)
379
(14.9)
350 90
(13.7) (3.5)
220
M10 (8.6)
10
240 (0.39) dia.
(9.4) 20
31 180 (0.78) dia. Dimensions are in mm (in.)
(1.2) (7.1) 13
30 30
(1.18)
(0.5)
(1.18)
L1 L2 L3 E
L1/L2/L3
M8
371
(14.6)
455
READY A
(17.9)
FAULT V
PROGRAM kW
8720MC
MC
REGENERATIVE
REGENERATIVE POWER
POWER SUPPLY
SUPPLY
L4/L5/L6
E E
10 303
10 M8 10 (0.39) (11.9)
(0.39) 390
(0.39) (15.4)
180
(7.1)
Refer to this table for active shunt solutions from Rockwell Automation Encompass Partners and intended for use with
Kinetix 2000, Kinetix 6000, Kinetix 6200, Kinetix 6500, and Kinetix 7000 drives.
For Bulletin 2097 shunt modules intended for use with Kinetix 300 servo drives, refer to Shunt Resistor Specifications on
page 346.
Select one of these Bulletin 1394 passive shunt modules when your Kinetix 6000, Kinetix 6200 or Kinetix 6500 drive
application exceeds the capacity of the internal (IAM/AM module) shunt resistor. These external passive shunt modules
wire to the Kinetix 6000 (catalog number 2094-BSP2) shunt module.
Specifications
External Shunt Shipping Weight, Bussmann
Cat. No. Drive Resistance Peak Power Peak Current Cont. Power Replacement Fuse
approx.
Voltage Ω kW A W kg (lb)
230V AC 1 41.0 101.25 FNQ-R-20-R1 (1)
1394-SR9A 4 300 3.63 (8)
460V AC 160 200 FWP50A14F
230V AC 1 41.0 101.25 FNQ-R-20-R1 (1)
1394-SR9AF 4 900 3.63 (8)
460V AC 160 200 FWP50A14F
1
230V AC 41.0 101.25 FNQ-R-20-R1 (1)
1394-SR36A 4 1800 8.6 (19)
460V AC 160 200 FWP50A14F
230V AC 1 41.0 101.25 FNQ-R-25-R1 (1)
1394-SR36AF 4 3600 9.0 (20)
460V AC 160 200 FWP50A14F
(1) Requires the use of an FNQ fuse with an adapter to allow the smaller body fuse to fit the larger FWP fuse holder.
Select one of these passive shunt modules when your Ultra3000 or Ultra5000 drive application exceeds the capacity of the
internal shunt resistor.
Specifications
Ultra3000/5000 (1) Shunt Module Fan Peak Peak Continuous Shipping Fuse
Drives Cat. No. Drive Voltage Resistance Power Current Power Weight Replacement
Voltage Ω
V AC kW A W kg (lb)
2098-xxx-005,
2098-xxx-010, 2090-UCSR-A300 36 4.0 10.5 300 1.51 (3.3) —
2098-xxx-020
230V AC N/A
2098-xxx-030 9101-1183 30 5.9 14.0 200 — CCMR-4-½ (2)
2098-xxx-075,
2098-xxx-150 2090-UCSR-P900 18 10.0 23.3 4.08 (9.0) FWP-10A14F (3)
2098-xxx-HV030, 900
2098-xxx-HV050 2090-SR120-09 120 5.3 6.7 3.63 (8.0) FWP-2.5A14F (3)
65.1
(2.5)
13.21 Clearance holes for #10 (M5) screws.
38.1 (0.5)
(1.5)
18.6 129
(0.7) (5.0)
6.35
(0.25)
Active Shunt
Adjust
Allen Bradley
Overtemp
DC Bus
UltraSeries
Active
Dimensions are in mm (in.)
186.7
(7.3) 198
(7.8)
97.3
(3.8)
143
5.6 (5.6)
(0.22)
77.4 (3.0)
Dimensions are in mm (in.)
50.8 (2)
25.4 (1) 218.4 (8.6)
150
Dimensions are in mm (in.)
8.0 (5.9) 25.0
(0.32) 100 (0.98)
280
(3.9) (11.0)
24.8
(0.98)
Side View
Front View
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering charts below to understand the configuration of your shunt. For questions regarding product
availability, contact your Allen-Bradley distributor.
2090 - SR xxx - xx
Continuous Power Rating
09 = 900 W
18 = 1800 W
Resistance Rating
120 = 120 Ω
040 = 40 Ω
SR = Shunt Resistor
Bulletin Number
1394 Shunt Modules for Kinetix 6200, Kinetix 6500, and Kinetix 6000 Servo Drives
1394 - SR xxxx
kW Rating
9A = 300 W continuous, 160,000 W peak, no fan
9AF = 900 W continuous, 160,000 W peak, no fan
36A = 1800 W continuous, 160,000 W peak, no fan
36AF = 3600 W continuous, 160,000 W peak, fan-cooled
SR = Shunt Resistor
Bulletin Number
Use Motion Analyzer software to match an RBM module to your servo motor compatible with Kinetix 2000,
Kinetix 6000, Kinetix 6200, Kinetix 6500, and Ultra3000-SE drive systems.
IMPORTANT Drive commands are the preferred and quickest method to bring your drive system to a controlled stop. When using
drive commands, the time between braking cycles is limited by the drive/motor/load combination. When the RBM
resistors are used to stop the motor, these conditions apply:
• One minute between braking cycles
• Maximum 15:1 motor inertia
• Maximum motor velocity at the start of braking
• Application must not exceed the current rating of the brake module
198.6
(7.82)
6.1
(0.24)
226.5
205.4 (8.92) Dimensions are in mm (in.)
(8.09) 238.3
(9.38)
11.7
(0.46)
35
190.6 4.6
(1.38)
(7.50) 70.0 (0.18)
(2.76)
195
(7.68)
16
(0.63)
328
(12.92)
305.6
340 Dimensions are in mm (in.)
(12.03)
(13.38)
10.4
(0.41)
55.6 4.6
190
(2.19) (0.18)
(7.49) 111
(4.38)
2
3
Item Description
1 6
1 Drive connections (TB1) connector
2 230V AC auxiliary power input (TB4) connector (1)
3 I/O (TB3) connector
4 Contactor status indicator
5 Auxiliary power status indicator (1)
6 Motor connections (TB2) connector
7 Motor cable shield clamps
7
(1) The 230V AC auxiliary power input (TB4) connector and auxiliary power
status indicator are present only on 2090-XB120-xx resistive brake modules.
RBM interface cables (motor power, RBM to drive) are available for Kinetix 6000, Kinetix 6200/Kinetix 6500, and
Ultra3000-SE drives. Refer to the table below for specific RBM to drive interface cable information.
For This Information Refer to
Cable catalog numbers for compatible drives page 435
Available cable lengths page 435
Cable dimensions page 440
Cable specifications page 436
2090 - XB xx - xx
Resistance Rating
32 = 32 Ω
16 = 16 Ω
6=6Ω
3=3Ω
1=1Ω
Current Rating
33 = 33 A 0-pk
120 = 106 A 0-pk
XB = Resistive Brake
Bulletin Number
The table below lists general power specifications and requirements for the 8720MC-RPS modules (catalog numbers
8720MC-RPS065 and 8720MC-RPS190).
Attribute 8720MC-RPS065 8720MC-RPS190
AC input voltage 324…506V AC rms three-phase
AC input frequency 47…63 Hz
AC input current
Nom 65 A rms 92 A 0-pk 190 A rms 268 A 0-pk
Max (1 minute) 98 A rms 138 A 0-pk 285 A rms 403 A 0-pk
Continuous output current 64 A DC 190 A DC
Output current (1 minute) 96 A DC 285 A DC
Refer to 8720MC Regenerative Power Supply User Manual, publication 8720MC-RM001, for additional specifications
and dimensions for the 8720MC-RPS modules listed in the table above.
The table below lists internal (built-in) and external precharge capacitance of the 8720MC-RPS modules.
Attribute 8720MC-RPS065 8720MC-RPS190
Capacitance of built-in capacitor 1900 μF 7600 μF
7000 μF 25000 μF
Built-in resistor (value/wattage) (22 Ω/120 W) (10 Ω/400 W)
External resistor (min resistance value) 110000 μF 165000 μF
Connect to PR1 and PR2 (20 Ω) (10 Ω)
220000 μF 495000 μF
External circuit (min resistance value) (4.7 Ω) (1.5 Ω)
IMPORTANT Large levels of load capacitance may require modification of the 8720MC-RPS internal precharge/discharge circuit.
Refer to the wiring instructions in the 8720MC Regenerative Power Supply Installation Manual, publication
8720MC-RM001, for information on how to determine the appropriate precharge/discharge resistance power value
(ohms/watt) to accommodate the capacitance of your system.
Ø 9.0
(0.35) 10.0
(0.39) Dimensions are in mm (in.)
127
Ø 18.0
(5.0)
(0.71)
30.0
(1.2)
9.0
(0.35)
395
(15.6)
333
(13.1)
READY A
FAULT V
PROGRAM kW
8720 MC
POWER SUPPLY
REGENERATIVE POWER SUPPLY
9.0 318
127 (0.35) 10.0 30.0 (12.2)
(5.0) (0.39) (1.2)
179
(7.0)
13 (0.5)
40 (1.6)
(1.2) (2.3) 86 (3.4)
M10 110 (4.3) 110 (4.3)
L2
L 1, L 3 L1 L2 L3
14 (0.6)
550 (21.7)
573 (22.6)
503 (19.8)
639.5 (25.18)
566.5 (22.30)
READY A
FAULT V
PROGRAM kW
8720 MC
REGENERATIVE POWER SUPPLY
E
P E
M8
(1.3)
P 10
33
30 (1.2)
(0.4)
10 (0.4)
N 45 N 83
30 125 (4.9) (1.8) (3.3)
20 (0.79)
8720MC-RPS065 8720MC-RPS065
(with front cover) (with front cover removed)
8720MC 2
Regenerative
Power Supply
8720MC-RPS065
3
READY A
READY A
FAULT V
FAULT V
PROGRAM kW
PROGRAM kW
8720 MC 4
REGENERATIVE POWER
POWER SUPPLY
SUPPLY
8720MC-RPS065
(front cover and regulator board removed)
Item Description
1 Operation panel (master unit only)
2 Power status indicator
3 Main power (TB1) terminal block
4 Regulator board (master unit only)
5 Sequence signal (TB3) terminal block
6 Control power (TB2) terminal block 6
L1
L2 L3 4
Item Description
L1AUX
3 L2AUX 1 DC bus terminals
L3AUX
PR1
PR2
5 2 Operation panel (master unit only)
PR3
+24V3
0V3 3 Power status indicator
SENS
+24V2 6
0V2 4 Main power terminals
MC1
MC2
5 Control power (TB2) terminal block
READY A READY A
PROGRAM kW PROGRAM kW
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the
catalog numbering table chart below to understand the configuration of your 8720MC Regenerative Power Supply. For
questions regarding product availability, contact your Allen-Bradley distributor.
Bulletin Number
Specifications
Line Reactor Maximum Continuous
8720MC- Inductance Inductance as % Weight, approx.
Current
uH Voltage Drop kg (lb)
A
LR03-032B 32 850 3% 17 (37.47)
LR05-048B 48 800 5% 21 (46.29)
LR10-062B 62 1100 10% 27 (59.52)
LR14-070B 70 1200 14% 38 (83.77)
(1) 100 800 10% 100 (220)
LR10-100B
(1) Order two 8720MC-LR10-100B line reactor units and wire in parallel for 200 A rating when used with the 8720MC-RPS190 RPS modules.
B C D
F
E
L G G
Line
Reactor A (1) B C (2) D E F (3) G H (4) I (5) J K K
mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) mm (in.)
8720MC-
6-(R22-6)
LR03-032B 345 112.5 120 112.5 140 100 4 to 7 127 80 15 4 to 15
(13.58) (4.42) (4.72) (4.42) (5.51) (3.93) (0.15 to 0.27) (4.99) (3.14) (0.59) (0.15 to 0.59) (0.23)
6-(R22-6)
LR05-048B 400 132.5 135 132.5 155 105 4 to 7 125 80 15 4 to 15
(15.74) (5.21) (5.31) (5.21) (6.10) (4.13) (0.15 to 0.27) (4.92) (3.14) (0.59) (0.15 to 0.59) (0.23)
6-(R22-6)
LR10-062B 440 145 150 145 160 110 4 to 9.5 (0.15 125 80 15 4 to 15
(17.32) (5.70) (5.90) (5.70) (6.29) (4.33) to 0.37) (4.92) (3.14) (0.59) (0.15 to 0.59) (0.23)
6-(R38-6)
LR14-070B 460 155 150 155 180 125 4 to 9.5 (0.15 140 80 15 4 to 15
(18.11) (6.10) (5.90) (6.10) (7.08) (4.92) to 0.37) (5.51) (3.14) (0.59) (0.15 to 0.59) (0.23)
(1) The tolerance is +/-2 mm (0.07 in.).
(2) The tolerance is +/-1 mm (0.03 in.).
(3) The tolerance is +1/-5 mm (+0.03/-0.19 in.).
(4) The tolerance is +/-5 mm (0.19 in.).
(5) The tolerance is +/-10 mm (0.39 in.).
L1 L1
80
(3.15)
L4 L4
75
(2.9)
467.2
L2 L2 (18.4) 414
80
(16.3)
(3.15)
L5 L5
75 488
(2.9) (19.2) max
L3 L3
80
(3.15) 29
(1.1)
L6 L6
26.6
38.6 AIR FLOW 10
(1.0)
(1.5) 6 x R38-8 (0.39)
Shown are two 8720MC-LR10-100B units in a typical
configuration for use with the 8720MC-RPS190 RPS module.
8720MC - LRxx x x x
Voltage
B = 380…460V AC
Current Rating
032 = 32 A
048 = 48 A
062 = 62 A
070 = 70 A
100 = 200 A (two 100 A units)
Enclosure Type
Blank = Open
A = NEMA Type 1
Inductance as % Voltage Drop
03 = 3%
05 = 5%
10 = 10%
14 = 14%
Bulletin Number
Notes:
This chapter provides Kinetix Motion Control servo drive and rotary motor combinations. Each drive family/motor
section includes:
• a motor/cable combinations table.
• a drive/motor performance specification table.
• torque/speed curves with each motor matched to the drive with optimum performance.
Performance specification data and curves reflect nominal system performance of a typical system with motor/drive at
rated ambient temperature and line voltage. For additional information on ambients, line conditions, and valid
combinations not shown in this chapter, refer to Motion Analyzer software.
IMPORTANT This system combinations chapter does not include all possible motor/drive combinations. Please refer to Motion
Analyzer software to verify compatibility. Download is available at http://www.ab.com/motion/software/analyzer.html.
Drive Family Rotary Motor Series Class Page Drive Family Rotary Motor Series Class Page
Kinetix 6000 Peak Enhancement Example 514 MP-Series Low Inertia Motors 597
MP-Series Low Inertia Motors 515 MP-Series Medium Inertia Motors 200V 606
Kinetix 6000 Kinetix 300 and
MP-Series Medium Inertia Motors 200V 530 MP-Series Food Grade Motors 400V 609
and and Servo Drives
Kinetix 6200/ MP-Series Food Grade Motors 400V 541 MP-Series Stainless Steel Motors 613
Kinetix 6500
Servo Drives MP-Series Stainless Steel Motors 548 TL-Series (Bulletin TLY) Motors 200V 615
RDD-Series Direct Drive Motors 400V 551 Kinetix 3 TL-Series (Bulletin TLY) Motors 621
200V
TL-Series (Bulletin TLY) Motors 200V 557 Servo Drives TL-Series (Bulletin TL) Motors 626
MP-Series Low Inertia Motors 561 MP-Series Low Inertia Motors 629
MP-Series Medium Inertia Motors 566 Ultra3000 MP-Series Medium Inertia Motors 200V 643
Kinetix 2000 and and
Servo Drives MP-Series Food Grade Motors 200V 567 MP-Series Food Grade Motors 400V 654
Ultra5000
MP-Series Stainless Steel Motors 569 Servo Drives MP-Series Stainless Steel Motors 659
TL-Series (Bulletin TLY) Motors 570 TL-Series (Bulletin TLY) Motors 200V 662
HPK-Series Asychronous Servo 576
Motors
Kinetix 7000 MP-Series Low Inertia Motors 583
400V
Servo Drives
MP-Series Medium Inertia Motors 588
RDD-Series Direct Drive Motors 593
IMPORTANT You can configure Kinetix 6000 460V (series B) drives to operate with up to 250% peak current for limited duty cycles.
Drive/actuator performance specifications are given with and without the peak enhancement feature enabled. For more
information, refer to Kinetix 6000 Drive Performance Example with Peak Enhancement Feature on page 514.
IMPORTANT Before your Kinetix 6000 drive will deliver enhanced peak performance, you must enable the peak enhancement feature
by configuring your drive by using DriveExplorer or RSLogix 5000 software.
Refer to the Kinetix 6000 Multi-axis Servo Drive User Manual, publication 2094-UM001, to recalculate torque and
accel/decel limit values, and paste them into the appropriate Axis Properties dialog box in RSLogix 5000 software.
For sizing your drive/motor combination by using series-B drives and the peak enhancement feature, use Motion Analyzer
software, version 4.6 or later.
In this example, the MPL-B330P motor, usually paired with the 2094-BM02 (series A) AM module, is shown paired with
the 2094-BM01-S (series B) AM module. The two curves illustrate how the 2094-BM01-S (series B) drive, when
configured for 250% peak, can achieve full motor performance.
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
IMPORTANT The 2094-BC07-M05-S and 2094-BM05-S (series B) modules are limited to 200% of continuous inverter current.
IMPORTANT The MP-Series low-inertia motors on this page are equipped with DIN connectors (specified by 4 or 7 in the catalog
number) and are not compatible with cables designed for motors equipped with bayonet connectors (specified by 2 in the
catalog number). The motors with bayonet connectors (for example, MPL-A310P-xx2xAA) are being discontinued and
require 2090-XXNxMP (bayonet) cables. For help with migration or to select bayonet cables, contact your Rockwell
Automation sales representative.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin MPL Motor Performance Specifications with Kinetix 6000 (230V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 6000
Rotary Motor Stall Current Stall Torque Output
rpm Stall Current Stall Torque 230V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
MPL-A1510V 8000 1.05 0.26 (2.3) 3.40 0.77 (6.8) 0.16 2094-AMP5-S
MPL-A1520U 7000 1.80 0.49 (4.3) 6.10 1.58 (13.9) 0.27 2094-AMP5-S
MPL-A1530U 7000 2.82 0.90 (8.0) 10.1 2.82 (24.9) 0.39 2094-AMP5-S
MPL-A210V 8000 3.09 0.55 (4.8) 10.2 1.52 (13.4) 0.37 2094-AMP5-S
0 0 0 0
0 2000 4000 6000 8000 0 2000 4000 6000 8000
Speed (rpm) Speed (rpm)
0 0 0 0
0 2000 4000 6000 8000 0 2000 4000 6000 8000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
0 0 0 0
0 1000 2000 3000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
5.0 44.2
3.0 26.5
1.0 8.85
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
4.0 35.4
4.0 35.4
2.0 17.7
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
20 177 20 177
15 133 15 133
10 88.5 10 88.5
5 44.2 5 44.2
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
20 177 20 177
15 133 15 133
10 88.5 10 88.5
5 44.2 5 44.2
0 0 0 0
0 1000 2000 3000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
20 177 20 177
15 133 15 133
10 88.5 10 88.5
5 44.2 5 44.2
0 0 0 0
0 250 500 750 1000 1250 1500 0 1000 2000 3000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
10 88.5 5 44.2
0 0 0 0
0 1000 2000 3000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
40 354
24 212
30 265
16 141
20 177
8 70.8
10 88.5
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives with MP-Series Low Inertia Motors
This section provides system combination information for the Kinetix 6000 and the Kinetix 6200/6500 (460V) drives
when matched with MP-Series low-inertia motors. Included are motor power/brake and feedback cable catalog numbers,
system performance specifications, and the optimum torque/speed curves.
IMPORTANT When using Kinetix 6000 (series B) drives, configured for enhanced peak performance, you can usually achieve full motor
performance with a smaller drive. Kinetix 6200 and Kinetix 6500 drives are configured for enhanced peak performance by
default. Expect the same peak performance from Kinetix 6200 and Kinetix 6500 drives as Kinetix 6000 (series B) drives
configured for enhanced peak performance.
Refer to Kinetix 6000 IAM/AM Module Series Change on page 276 for more Kinetix 6000 enhanced-peak information.
IMPORTANT The MP-Series low-inertia motors on this page are equipped with DIN connectors (specified by 4 or 7 in the catalog
number) and are not compatible with cables designed for motors equipped with bayonet connectors (specified by 2 in the
catalog number). The motors with bayonet connectors (for example, MPL-A310P-xx2xAA) are being discontinued and
require 2090-XXNxMP (bayonet) cables. For help with migration or to select bayonet cables, contact your Rockwell
Automation sales representative.
Bulletin MPL Motor Performance Specifications with Kinetix 6200/6500 (460V) Drives
System System System Peak System Peak Motor Rated Kinetix 6200/
Max Speed Continuous Continuous
Rotary Motor Stall Current Stall Torque Output Kinetix 6500
rpm Stall Current Stall Torque
A 0-pk N•m (lb•in) kW 460V Drives
A 0-pk N•m (lb•in)
MPL-B1510V 8000 0.95 0.26 (2.3) 3.10 0.77 (6.8) 0.16 2094-BMP5-M
MPL-B1520U 7000 1.80 0.49 (4.3) 6.10 1.58 (13.9) 0.27 2094-BMP5-M
MPL-B1530U 7000 2.0 0.90 (8.0) 7.20 2.82 (24.9) 0.39 2094-BMP5-M
MPL-B210V 8000 1.75 0.55 (4.9) 5.80 1.52 (13.4) 0.37 2094-BMP5-M
9.90 4.12 (36.4) 2094-BMP5-M
MPL-B220T 6000 3.30 1.61 (14.2) 0.62
11.3 4.74 (41.9) 2094-BM01-M
9.90 7.24 (64.0) 2094-BMP5-M
MPL-B230P 5000 2.60 2.10 (18.6) 0.86
11.3 8.20 (73.0) 2094-BM01-M
MPL-B310P 5000 2.4 1.6 (14.1) 7.10 3.6 (32) 0.77 2094-BMP5-M
4.0 2.7 (23.9) 9.90 5.9 (52.2) 2094-BMP5-M
MPL-B320P 5000 1.5
4.5 3.10 (27) 14.0 8.2 (72.5) 2094-BM01-M
4.0 2.7 (23.9) 9.90 6.8 (60.2) 2094-BMP5-M
MPL-B330P 5000 1.8
6.1 4.18 (37) 19.0 11.1 (98) 2094-BM01-M
21.6 13.1 (116) 2094-BM01-M
MPL-B420P 5000 6.3 4.74 (42) 1.9
22.0 13.5 (119) 2094-BM02-M
8.6 6.2 (54.9) 21.6 13.9 (123) 2094-BM01-M
MPL-B430P 5000 2.2
9.2 6.55 (58) 32.0 19.8 (175) 2094-BM02-M
4.0 4.9 (43.3) 9.90 11.0 (97.3) 2094-BMP5-M
MPL-B4530F 3000 2.1
6.7 8.36 (74) 21.0 20.3 (180) 2094-BM01-M
8.6 7.1 (62.8) 21.6 15.1 (133) 2094-BM01-M
MPL-B4530K 4000 2.6
9.9 8.25 (73) 31.0 20.3 (179) 2094-BM02-M
8.6 9.5 (84.1) 21.6 20.9 (185) 2094-BM01-M
MPL-B4540F 3000 2.6
9.1 10.20 (90) 29.0 27.1 (240) 2094-BM02-M
8.6 10.5 (92.9) 21.6 22.7 (201) 2094-BM01-M
MPL-B4560F 3000 3.2
11.8 14.0 (124) 36.0 34.4 (304) 2094-BM02-M
8.6 7.9 (69.9) 21.6 16.6 (147) 2094-BM01-M
MPL-B520K 4000 3.5
11.5 10.7 (95) 33.0 23.2 (205) 2094-BM02-M
8.6 15.8 (139) 21.6 37.9 (335) 2094-BM01-M
MPL-B540D 2000 3.4
10.5 19.4 (172) 23.0 41.0 (362) 2094-BM02-M
MPL-B540K 4000 20.4 19.4 (171) 60.0 48.6 (430) 5.4 2094-BM03-M
MPL-B560F 3000 20.9 26.8 (237) 68.0 67.8 (600) 5.5 2094-BM03-M
75.0 74.6 (660) 2094-BM03-M
MPL-B580F 3000 26.1 34.0 (300) 7.1
94.0 87.0 (770) 2094-BM05-M
30.0 31.7 (280) 75.0 67.0 (592) 2094-BM03-M
MPL-B580J 3800 7.9
32.0 34.0 (301) 94.0 81.0 (716) 2094-BM05-M
30.0 34.4 (304) 2094-BM03-M
MPL-B640F 3000 65.0 72.3 (640) 6.1
32.0 36.7 (325) 2094-BM05-M
System System System Peak System Peak Motor Rated Kinetix 6200/
Max Speed Continuous Continuous
Rotary Motor Stall Current Stall Torque Output Kinetix 6500
rpm Stall Current Stall Torque
A 0-pk N•m (lb•in) kW 460V Drives
A 0-pk N•m (lb•in)
MPL-B660F 3000 38.5 48.0 (425) 96.0 101 (895) 6.1 2094-BM05-M
30.0 55.4 (490) 75.0 125 (1105) 2094-BM03-M
MPL-B680D 2000 9.3
34.0 62.8 (556) 94.0 154 (1365) 2094-BM05-M
MPL-B680F 3000 47.9 60.0 (531) 96.0 108 (960) 7.5 2094-BM05-M
MPL-B860D 2000 47.3 83.0 (735) 95.5 152 (1350) 12.5 2094-BM05-M
MPL-B880C 1500 47.5 110 (973) 97.5 203 (1800) 12.6 2094-BM05-M
MPL-B880D 2000 48.9 79.9 (706) 96.0 147 (1300) 12.6 2094-BM05-M
MPL-B960B 1200 42.5 130 (1150) 94.0 231 (2050) 12.7 2094-BM05-M
MPL-B980B 1000 40.0 162 (1440) 94.0 278 (2460) 15.2 2094-BM05-M
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 5.000 or later.
Bulletin MPL Motor Performance Specifications with Kinetix 6000 (460V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 6000
Rotary Motor Stall Current Stall Torque Output
rpm Stall Current Stall Torque 460V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
MPL-B1510V 8000 0.95 0.26 (2.3) 3.10 0.77 (6.8) 0.16 BMP5-S @ 150%
5.90 1.53 (13.3) BMP5-S @ 150%
MPL-B1520U 7000 1.80 0.49 (4.3) 0.27
6.10 1.58 (13.9) BMP5-S @ 250%
5.90 2.34 (20.7) BMP5-S @ 150%
MPL-B1530U 7000 2.0 0.90 (8.0) 0.39
7.20 2.82 (24.9) BMP5-S @ 250%
MPL-B210V 8000 1.75 0.55 (4.9) 5.80 1.52 (13.4) 0.37 BMP5-S @ 150%
9.90 4.12 (36.4) BMP5-S @ 250%
MPL-B220T 6000 3.30 1.61 (14.2) 0.62
11.3 4.74 (41.9) BM01-S @ 150%
9.90 7.24 (64.0) BMP5-S @ 250%
MPL-B230P 5000 2.60 2.10 (18.6) 0.86
11.3 8.20 (73.0) BM01-S @ 150%
5.90 3.2 (28) BMP5-S @ 150%
MPL-B310P 5000 2.4 1.6 (14) 0.77
7.10 3.6 (32) BMP5-S @ 250%
13.0 7.5 (66) BM01-S @ 150%
MPL-B320P 5000 4.5 3.10 (27) 1.5
14.0 8.2 (72.5) BM01-S @ 250%
13.0 8.0 (71) BM01-S @ 150%
MPL-B330P 5000 6.1 4.18 (37) 1.8
19.0 11.1 (98) BM01-S @ 250%
13.0 13.1 (116) BM01-S @ 250%
MPL-B420P 5000 6.3 4.74 (42) 21.8 13.4 (118) 1.9 BM02-S @ 150%
22.0 13.5 (119) BM02-S @ 250%
21.8 14.4 (127) BM02-S @ 150%
MPL-B430P 5000 9.2 6.55 (58) 2.2
32.0 19.8 (175) BM02-S @ 250%
13.0 13.9 (123) BM01-S @ 150%
MPL-B4530F 3000 6.7 8.36 (74) 2.1
21.0 20.3 (180) BM01-S @ 250%
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives/MP-Series Low Inertia Motor Curves
2094-BMP5-S @ 150% or 2094-BMP5-M 2094-BMP5-S @ 250% or 2094-BMP5-M
and MPL-B1510V and MPL-B1520U
Torque 0.800 7.08 Torque Torque 1.600 14.1 Torque
(N•m) (lb•in) (N•m) (lb•in)
0.700 6.19 1.400 12.4
0.600 Peak curve represents 5.31 1.200 Peak curve represents 10.6
460V and 400V inputs 460V and 400V inputs
0.500 4.42 1.000 8.85
0 0 0 0
0 2000 4000 6000 8000 0 2000 4000 6000 8000
Speed (rpm) Speed (rpm)
0 0 0 0
0 2000 4000 6000 8000 0 2000 4000 6000 8000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives/MP-Series Low Inertia Motor Curves, Continued
2094-BMP5-S @ 250% or 2094-BMP5-M 2094-BM01-S @ 250% or 2094-BM01-M
and MPL-B310P and MPL-B320P
Torque 4.0 35.4 Torque Torque 8.0 70.8 Torque
(N•m) (lb•in) (N•m) (lb•in)
3.5 31.0 7.0 61.9
4.0 35.4
4 35.4
2.0 17.7
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
20 177
15 133
15 133
10 88
10 88.5
5 44
5 44.2
0 0 0 0
0 1000 2000 3000 4000 5000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives/MP-Series Low Inertia Motor Curves, Continued
2094-BM02-S @ 250% or 2094-BM02-M 2094-BM02-S @ 250% or 2094-BM02-M
and MPL-B4530K and MPL-B4540F
Torque 25 221 Torque Torque 30 265 Torque
(N•m) (lb•in) (N•m) (lb•in)
25 221
20 177
20 177
15 133
15 133
10 88.5
10 88.5
5 44.2 5 44.2
0 0 0 0
0 1000 2000 3000 4000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
20 177
30 265
15 133
20 177
10 88.5
10 88.5
5 44.2
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
30 265
30 265
20 177
20 177
10 88.5
10 88.5
0 0
0 0 0 1000 2000 3000 4000
0 500 1000 1500 2000
Speed (rpm)
Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives/MP-Series Low Inertia Motor Curves, Continued
2094-BM03-S @ 250% or 2094-BM03-M 2094-BM05-S @ 200% or 2094-BM05-M
and MPL-B560F and MPL-B580F
Torque 70 619 Torque Torque 100 885 Torque
(N•m) (lb•in) (N•m) (lb•in)
60 531
80 708
50 442
60 531
40 354
30 265
40 354
20 177
20 177
10 88.5
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
60 531 60 531
40 354 40 354
20 177 20 177
0 0 0 0
0 1000 2000 3000 4000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
40 354 60 531
40 354
20 177
20 177
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives/MP-Series Low Inertia Motor Curves, Continued
2094-BM05-S @ 200% or 2094-BM05-M 2094-BM05-S @ 200% or 2094-BM05-M
and MPL-B680F and MPL-B860D
Torque 120 1062 Torque Torque 160 1416 Torque
(N•m) (lb•in) (N•m) (lb•in)
100 885 140 1239
120 1062
80 708
100 885
60 531 80 708
40 354 60 531
40 354
20 177
20 177
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000
Speed (rpm) Speed (rpm)
40 354
50 442
20 177
0 0 0
0 250 500 750 1000 1250 1500 0 500 1000 1500 2000
Speed (rpm) Speed (rpm)
50 442 50 442
0 0
0 0
0 200 400 600 800 1000
0 300 600 900 1200
Speed (rpm)
Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
2090-CPxM7DF-10AAxx (standard)
MPM-A1651F 2090-CPxM7DF-10AFxx (continuous-flex) 2090-CFBM7DF-CEAAxx (standard) (2)
2090-CFBM7DF-CEAFxx (continuous-flex)
2090-CPxM7DF-08AAxx (standard) Resolver Feedback
MPM-A1652F, MPM-A1653F 2090-CPxM7DF-08AFxx (continuous-flex)
(1) Use low-profile connector kit (catalog number 2090-K6CK-D15M) or panel-mounted breakout components on drive end. Refer to Breakout Components and Connector Kits
beginning on page 442.
(2) These cables apply to Kinetix 6000 drives and MPM-Axxxxx-2 motors (resolver feedback).
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin MPM Motor Performance Specifications with Kinetix 6000 (230V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 6000
Rotary Motor Stall Current Stall Torque Output
rpm Stall Current Stall Torque 230V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
30.0 6.5 (57.5) 2094-AM02-S
MPM-A1151M 6000 10.3 2.3 (20.3) 0.90
30.5 6.6 (58.4) 2094-AM03-S
30.0 9.9 (87.6) 2094-AM02-S
MPM-A1152F 5000 14.9 4.7 (41.6) 1.40
44.8 13.5 (119) 2094-AM03-S
15.0 6.0 (53.1) 30.0 10.7 (94.7) 2094-AM02-S
MPM-A1153F 5000 1.45
18.6 6.5 (57.5) 49.0 16.1 (142) 2094-AM03-S
49.0 13.2 (117) 2094-AM03-S
MPM-A1302F 4500 19.8 6.6 (58.4) 1.65
50.2 13.5 (119) 2094-AM05-S
15.0 7.6 (67.2) 30.0 13.2 (117) 2094-AM02-S
MPM-A1304F 4000 2.20
22.5 9.2 (81.4) 48.3 19.3 (171) 2094-AM03-S
24.5 9.3 (82.3) 49.0 15.2 (134) 2094-AM03-S
MPM-A1651F 5000 2.50
35.6 10.7 (94.7) 73.4 20.3 (179) 2094-AM05-S
24.5 11.0 (97.3) 49.0 19.7 (174) 2094-AM03-S
MPM-A1652F 4000 4.03
38.5 13.4 (119) 73.4 27.7 (245) 2094-AM05-S
24.5 11.7 (103) 49.0 21.1 (187) 2094-AM03-S
MPM-A1653F 4000 5.10
48.7 18.6 (165) 73.4 29.6 (262) 2094-AM05-S
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
0 0 0 0
0 1000 2000 3000 4000 = Intermittent operating region 0 1000 2000 3000 4000
Speed (rpm) = Continuous operating region Speed (rpm)
Kinetix 6000 / Kinetix 6200/6500 (460V) Drives with MP-Series Medium Inertia Motors
This section provides system combination information for the Kinetix 6000 and Kinetix 6200/6500 (460V) drives when
matched with MP-Series medium-inertia motors. Included are motor power/brake and feedback cable catalog numbers,
system performance specifications, and the optimum torque/speed curves.
IMPORTANT When using Kinetix 6000 (series B) drives, configured for enhanced peak performance, you can usually achieve full motor
performance with a smaller drive. Kinetix 6200 and Kinetix 6500 drives are configured for enhanced peak performance by
default. Expect the same peak performance from Kinetix 6200 and Kinetix 6500 drives as Kinetix 6000 (series B) drives
configured for enhanced peak performance.
Refer to Kinetix 6000 IAM/AM Module Series Change on page 276 for more Kinetix 6000 enhanced-peak information.
(1) Use low-profile connector kit (catalog number 2090-K6CK-D15M) or panel-mounted breakout components on drive end. Refer to Breakout Components and Connector Kits
beginning on page 442.
(2) These cables apply to Kinetix 6000 drives and MPM-Bxxxxx-2 motors (resolver feedback).
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin MPM Motor Performance Specifications with Kinetix 6200/6500 (460V) Drives
System System System Peak System Peak Motor Rated Kinetix 6200/
Max Speed Continuous Continuous
Rotary Motor Stall Current Stall Torque Output Kinetix 6500
rpm Stall Current Stall Torque
A 0-pk N•m (lb•in) kW 460V Drives
A 0-pk N•m (lb•in)
MPM-B1151F 5000 3.1 2.3 (20.3) 9.9 6.6 (58.4) 0.75 2094-BMP5-M
MPM-B1151T 7000 6.9 2.3 (20.3) 20.5 5.8 (51.3) 0.90 2094-BM01-M
MPM-B1152C 3000 4.1 5.0 (44.2) 12.4 13.5 (119) 1.20 2094-BM02-M
MPM-B1152F 5200 7.0 5.0 (44.2) 21.1 13.3 (118) 1.40 2094-BM01-M
MPM-B1152T 7000 12.6 5.0 (44.2) 36.5 13.1 (116) 1.40 2094-BM02-M
MPM-B1153E 3500 7.1 6.5 (57.5) 21.6 19.7 (174) 1.40 2094-BM01-M
MPM-B1153F 5500 10.5 6.4 (56.6) 32.0 19.7 (174) 1.40 2094-BM02-M
MPM-B1153T 7000 18.3 6.4 (56.6) 45.0 14.5 (128) 1.45 2094-BM03-M
MPM-B1302F 4500 8.6 6.6 (58.4) 21.5 13.0 (115) 1.65 2094-BM01-M
MPM-B1302M 6000 14.4 6.6 (58.4) 32.4 13.3 (118) 1.65 2094-BM02-M
MPM-B1302T 7000 19.3 6.7 (59.3) 43.4 13.3 (118) 1.65 2094-BM03-M
MPM-B1304C 2750 8.0 10.3 (91.1) 21.5 26.4 (233) 2.00 2094-BM01-M
MPM-B1304E 4000 12.3 10.2 (90.3) 34.2 27.1 (240) 2.20 2094-BM02-M
MPM-B1304M 6000 21.8 10.4 (92.0) 60.6 27.1 (240) 2.20 2094-BM03-M
MPM-B1651C 3500 11.7 11.4 (101) 29.2 23.2 (205) 2.50 2094-BM02-M
MPM-B1651F 5000 20.4 11.4 (101) 50.9 23.2 (205) 2.50 2094-BM03-M
MPM-B1651M 5000 25.8 11.3 (100) 56.8 21.4 (189) 2.50 2094-BM03-M
MPM-B1652C 2500 13.2 16.4 (145) 33.6 40.2 (356) 3.80 2094-BM02-M
MPM-B1652E 3500 24.0 21.1 (187) 60.5 48.0 (425) 4.30 2094-BM03-M
MPM-B1652F 4500 33.0 21.1 (187) 84.1 48.0 (424) 4.30 2094-BM05-M
MPM-B1653C 2500 23.0 26.7 (236) 59.2 67.7 (599) 4.60 2094-BM03-M
MPM-B1653E 3500 30.0 26.8 (237) 72.9 62.0 (549) 5.10 2094-BM03-M
MPM-B1653F 4000 40.1 31.0 (274) 94.3 56.0 (495) 5.10 2094-BM05-M
MPM-B2152C 2500 30.0 36.7 (325) 55.4 72.2 (639) 5.60 2094-BM03-M
MPM-B2152F 4500 48.9 34.1 (302) 97.8 72.3 (495) 5.90 2094-BM05-M
MPM-B2152M 5000 48.9 34.1 (302) 76.3 52.9 (468) 5.90 2094-BM05-M
MPM-B2153B 2000 27.6 48.0 (425) 60.0 101 (894) 6.80 2094-BM03-M
MPM-B2153E 3000 45.5 47.9 (424) 97.8 101 (894) 7.20 2094-BM05-M
MPM-B2153F 3800 48.9 45.6 (403) 97.8 99.0 (875) 7.20 2094-BM05-M
MPM-B2154B 2000 40.7 62.7 (555) 97.8 154 (1362) 6.90 2094-BM05-M
MPM-B2154E 3000 48.9 55.9 (495) 97.8 112 (990) 7.50 2094-BM05-M
MPM-B2154F 3300 48.9 56.2 (497) 83.6 88.0 (778) 7.50 2094-BM05-M
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 5.000 or later.
Bulletin MPM Motor Performance Specifications with Kinetix 6000 (460V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 6000
Rotary Motor Stall Current Stall Torque Output
rpm Stall Current Stall Torque 460V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
5.9 4.3 (38.0) 2094-BMP5-S @ 150%
MPM-B1151F 5000 3.1 2.3 (20.3) 0.75
9.9 6.6 (58.4) 2094-BMP5-S @ 250%
13.0 4.1 (36.3) 2094-BM01-S @ 150%
MPM-B1151T 7000 6.9 2.3 (20.3) 0.90
20.5 5.8 (51.3) 2094-BM01-S @ 250%
5.9 7.2 (63.7) 2094-BMP5-S @ 150%
MPM-B1152C 3000 4.1 5.0 (44.2) 10.0 11.3 (100) 1.20 2094-BMP5-S @ 250%
12.4 13.5 (119) 2094-BM01-S @ 150%
13.0 9.0 (79.6) 2094-BM01-S @ 150%
MPM-B1152F 5200 7.0 5.0 (44.2) 1.40
21.1 13.3 (118) 2094-BM01-S @ 250%
21.8 8.5 (75.2) 2094-BM02-S @ 150%
MPM-B1152T 7000 12.6 5.0 (44.2) 1.40
36.5 13.1 (116) 2094-BM02-S @ 250%
21.5 13.0 (115) 2094-BM01-S @ 150%
MPM-B1153E 3500 7.1 6.5 (57.5) 1.40
21.6 19.7 (174) 2094-BM01-S @ 250%
21.8 14.4 (127) 2094-BM02-S @ 150%
MPM-B1153F 5500 10.5 6.4 (56.6) 1.40
32.0 19.7 (174) 2094-BM02-S @ 250%
MPM-B1153T 7000 18.3 6.4 (56.6) 45.0 14.5 (128) 1.45 2094-BM03-S @ 150%
13.0 8.9 (78.8) 2094-BM01-S @ 150%
MPM-B1302F 4500 8.6 6.6 (58.4) 1.65
21.5 13.0 (115) 2094-BM01-S @ 250%
21.8 9.9 (87.6) 2094-BM02-S @ 150%
MPM-B1302M 6000 14.4 6.6 (58.4) 1.65
32.4 13.3 (118) 2094-BM02-S @ 250%
14.6 6.0 (53.1) 36.5 11.8 (104) 2094-BM02-S @ 250%
MPM-B1302T 7000 1.65
19.3 6.7 (59.3) 43.4 13.3 (118) 2094-BM03-S @ 150%
13.0 17.6 (156) 2094-BM01-S @ 150%
MPM-B1304C 2750 8.0 10.3 (91.1) 2.00
21.5 26.4 (233) 2094-BM01-S @ 250%
21.8 19.0 (168) 2094-BM02-S @ 150%
MPM-B1304E 4000 12.3 10.2 (90.3) 2.20
34.2 27.1 (240) 2094-BM02-S @ 250%
45.0 21.5 (190) 2094-BM03-S @ 150%
MPM-B1304M 6000 21.8 10.4 (92.0) 2.20
60.6 27.1 (240) 2094-BM03-S @ 250%
21.8 19.4 (172) 2094-BM02-S @ 150%
MPM-B1651C 3500 11.7 11.4 (101) 2.50
29.2 23.2 (205) 2094-BM02-S @ 250%
45.0 21.6 (191) 2094-BM03-S @ 150%
MPM-B1651F 5000 20.4 11.4 (101) 2.50
50.9 23.2 (205) 2094-BM03-S @ 250%
45.0 18.8 (166) 2094-BM03-S @ 150%
MPM-B1651M 5000 25.8 11.3 (100) 2.50
56.8 21.4 (189) 2094-BM03-S @ 250%
21.8 28.7 (254) 2094-BM02-S @ 150%
MPM-B1652C 2500 13.2 16.4 (145) 3.80
33.6 40.2 (356) 2094-BM02-S @ 250%
45.0 38.4 (340) 2094-BM03-S @ 150%
MPM-B1652E 3500 24.0 21.1 (187) 4.30
60.5 48.0 (425) 2094-BM03-S @ 250%
Kinetix 6000 / Kinetix 6200/6500 (460V) Drives/MP-Series Medium Inertia Motor Curves
0 0 0 0
0 1000 2000 3000 4000 5000 0 2000 4000 6000 8000
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
0 0 0 0
0 2000 4000 6000 8000 0 1000 2000 3000 4000
Kinetix 6000 / Kinetix 6200/6500 (460V) Drives/MP-Series Medium Inertia Motor Curves, Continued
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 2000 4000 6000 8000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
0 0 0 0
0 2000 4000 6000 8000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
Kinetix 6000 / Kinetix 6200/6500 (460V) Drives/MP-Series Medium Inertia Motor Curves, Continued
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
16.0 30 265
142
12.0 106
20 177
8.0 70.8
10 88.5
4.0 35.4
0 0 0 0
0 1000 2000 3000 4000 5000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
Kinetix 6000 / Kinetix 6200/6500 (460V) Drives/MP-Series Medium Inertia Motor Curves, Continued
2094-BM03-S @ 250% or 2094-BM03-M 2094-BM05-S @ 200% or 2094-BM05-M
and MPM-B1652E and MPM-B1652F
Torque 50 442 Torque Torque 50 442 Torque
(N•m) (lb•in) (N•m) (lb•in)
40 354 40 354
30 265 30 265
20 177 20 177
10 88.5 10 88.5
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000 5000
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
40.0 60 531
354
30.0 265
40 354
20.0 177
20 177
10.0 88.5
0 0 0 0
0 1000 2000 3000 4000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
Kinetix 6000 / Kinetix 6200/6500 (460V) Drives/MP-Series Medium Inertia Motor Curves, Continued
2094-BM05-S @ 200% or 2094-BM05-M 2094-BM05-S @ 200% or 2094-BM05-M
and MPM-B2152F and MPM-B2152M
Torque 100 885 Torque Torque 70.0 619 Torque
(N•m) (lb•in) (N•m) (lb•in)
60.0 531
80 708
50.0 442
60 531 40.0 354
30.0 265
40 354
20.0 177
20 177
10.0 88.5
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
75 664 75 664
60 531 60 531
45 398 45 398
30 30 265
265
15 15 133
133
0 0 0 0
0 500 1000 1500 2000 0 500 1000 1500 2000 2500 3000
80 708
40 354
60 531
40 354
20 177
20 177
0 0 0 0
0 1000 2000 3000 4000 0 500 1000 1500 2000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
Kinetix 6000 / Kinetix 6200/6500 (460V) Drives/MP-Series Medium Inertia Motor Curves, Continued
40 354
40 354
20 177 20 177
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
Bulletin MPF Motor Performance Specifications with Kinetix 6000 (230V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 6000
Rotary Motor Stall Current Stall Torque Output
rpm Stall Current Stall Torque 230V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
10.5 2.91 (25.7) 2094-AMP5-S
MPF-A310P 5000 4.91 1.58 (14.0) 0.73
14.0 3.61 (31.9) 2094-AM01-S
17.0 6.97 (61.6) 2094-AM01-S
MPF-A320H 3500 6.10 3.05 (27.0) 1.0
19.3 7.91 (70.0) 2094-AM02-S
8.50 2.88 (25.5) 17.0 5.07 (44.8) 2094-AM01-S
MPF-A320P 5000 1.3
9.00 3.05 (27.0) 29.5 7.91 (70.0) 2094-AM02-S
30.0 8.47 (74.9) 2094-AM02-S
MPF-A330P 5000 12.0 3.85 (34.0) 1.6
38.0 10.32 (91.2) 2094-AM03-S
30.0 13.20 (117) 2094-AM02-S
MPF-A430H 3500 12.2 6.21 (55.0) 1.8
45.0 19.82 (175) 2094-AM03-S
49.0 15.36 (136) 2094-AM03-S
MPF-A430P 5000 16.80 5.94 (52.5) 1.9
67.0 19.80 (175) 2094-AM05-S
49.0 17.01 (150) 2094-AM03-S
MPF-A4530K 4000 19.50 8.08 (71.4) 2.3
62.0 20.30 (179) 2094-AM05-S
49.0 23.56 (208) 2094-AM03-S
MPF-A4540F 3000 18.40 10.15 (89.7) 2.5
58.0 27.10 (239) 2094-AM05-S
24.5 11.40 (100) 49.0 21.68 (192) 2094-AM03-S
MPF-A540K 4000 4.1
41.5 19.42 (171) 73.4 31.55 (279) 2094-AM05-S
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
4.0 35.4
2.0 17.7
2.0 17.7
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
15 133 15 133
10 88.5 10 88.5
5 44.2 5 44.2
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
20 177
15 133
15 133
10 88.5
10 88.5
5 44.2 5 44.2
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000
Speed (rpm) Speed (rpm)
24 212
16 141
8 70.8
0 0
0 1000 2000 3000 4000
Speed (rpm)
= Intermittent operating region
= Continuous operating region
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives with MP-Series Food Grade Motors
This section provides system combination information for the Kinetix 6000 and the Kinetix 6200/6500 (460V) drives
when matched with MP-Series food-grade motors. Included are motor power/brake and feedback cable catalog numbers,
system performance specifications, and the optimum torque/speed curves.
IMPORTANT When using Kinetix 6000 (series B) drives, configured for enhanced peak performance, you can usually achieve full motor
performance with a smaller drive. Kinetix 6200 and Kinetix 6500 drives are configured for enhanced peak performance by
default. Expect the same peak performance from Kinetix 6200 and Kinetix 6500 drives as Kinetix 6000 (series B) drives
configured for enhanced peak performance.
Refer to Kinetix 6000 IAM/AM Module Series Change on page 276 for more Kinetix 6000 enhanced-peak information.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin MPF Motor Performance Specifications with Kinetix 6200/6500 (460V) Drives
System System System Peak System Peak Motor Rated Kinetix 6200/
Max Speed Continuous Continuous
Rotary Motor Stall Current Stall Torque Output Kinetix 6500
rpm Stall Current Stall Torque
A 0-pk N•m (lb•in) kW 460V Drives
A 0-pk N•m (lb•in)
MPF-B310P 5000 2.30 1.60 (14) 7.10 3.6 (32) 0.77 2094-BMP5-M
4.0 2.90 (25.6) 9.90 6.0 (53.1) 2094-BMP5-M
MPF-B320P 5000 1.5
4.24 3.10 (27) 14.0 7.8 (69) 2094-BM01-M
4.0 2.90 (25.6) 9.90 6.5 (57.5) 2094-BMP5-M
MPF-B330P 5000 1.6
5.70 4.18 (37) 19.0 11.1 (98) 2094-BM01-M
8.60 6.20 (54.9) 21.5 13.9 (123) 2094-BM01-M
MPF-B430P 5000 2.0
9.20 6.55 (58) 32.0 19.8 (175) 2094-BM02-M
8.60 7.10 (62.8) 21.5 15.1 (133) 2094-BM01-M
MPF-B4530K 4000 2.4
9.90 8.25 (73) 31.0 20.3 (179) 2094-BM02-M
8.60 9.50 (84.1) 21.5 20.9 (185) 2094-BM01-M
MPF-B4540F 3000 2.5
9.10 10.20 (90) 29.0 27.1 (240) 2094-BM02-M
MPF-B540K 4000 20.5 19.4 (171) 60.0 48.6 (430) 4.1 2094-BM03-M
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 5.000 or later.
Bulletin MPF Motor Performance Specifications with Kinetix 6000 (460V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 6000
Rotary Motor Stall Current Stall Torque Output
rpm Stall Current Stall Torque 460V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
5.90 3.2 (28) 2094-BMP5-S @ 150%
MPF-B310P 5000 2.30 1.6 (14) 0.77
7.10 3.6 (32) 2094-BMP5-S @ 250%
4.00 2.90 (26) 5.90 3.9 (34) 2094-BMP5-S @ 150%
MPF-B320P 5000 13.0 7.5 (66) 1.5 2094-BM01-S @ 150%
4.24 3.10 (27)
14.0 7.8 (69) 2094-BM01-S @ 250%
13.0 8.2 (72) 2094-BM01-S @ 150%
MPF-B330P 5000 5.70 4.18 (37) 1.6
19.0 11.1 (98) 2094-BM01-S @ 250%
21.8 14.2 (125) 2094-BM02-S @ 150%
MPF-B430P 5000 9.20 6.55 (58) 2.0
32.0 19.8 (175) 2094-BM02-S @ 250%
21.8 15.4 (136) 2094-BM02-S @ 150%
MPF-B4530K 4000 9.90 8.25 (73) 2.4
31.0 20.3 (179) 2094-BM02-S @ 250%
21.8 21.4 (189) 2094-BM02-S @ 150%
MPF-B4540F 3000 9.10 10.20 (90) 2.5
29.0 27.1 (240) 2094-BM02-S@ 250%
45.0 37.9 (335) 2094-BM03-S @ 150%
MPF-B540K 4000 20.5 19.4 (171) 4.1
60.0 48.6 (430) 2094-BM03-S @ 250%
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 5.000 or later.
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives/MP-Series Food Grade Motor Curves
2094-BMP5-S @ 250% or 2094-BMP5-M 2094-BM01-S @ 250% or 2094-BM01-M
and MPF-B310P and MPF-B320P
Torque 4.0 35.4 Torque Torque 8.0 70.8 Torque
(N•m) (lb•in) (N•m) (lb•in)
3.5 31.0 7.0 61.9
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives/MP-Series Food Grade Motor Curves, Continued
6.0 53.1 10 88
4.0 35.4
5 44
2.0 17.7
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
20 177
15 133
15 133
10 88.5
10 88.5
5 44.2 5 44.2
0 0 0 0
0 1000 2000 3000 4000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
40 354
30 265
20 177
10 88.5
0 0
0 1000 2000 3000 4000
Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin MPS Motor Performance Specifications with Kinetix 6000 (230V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 6000
Rotary Motor Stall Current Stall Torque Output
rpm Stall Current Stall Torque 230V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
8.50 3.10 (27) 17.0 5.80 (51) 2094-AM01-S
MPS-A330P 5000 30.0 9.30 (82) 1.3 2094-AM02-S
9.80 3.60 (32.0)
38.0 11.10 (98) 2094-AM03-S
30.0 15.9 (140) 2094-AM02-S
MPS-A4540F 3000 14.4 8.1 (72) 49.0 24.2 (214) 1.4 2094-AM03-S
56.0 27.1 (240) 2094-AM05-S
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000
= Intermittent operating region
Speed (rpm) Speed (rpm)
= Continuous operating region
Kinetix 6000 / Kinetix 6200/6500 (460V) Drives with MP-Series Stainless Steel Motors
This section provides system combination information for the Kinetix 6000 and the Kinetix 6200/Kinetix 6500 (460V)
drives when matched with MP-Series stainless-steel motors. Included are motor power/brake and feedback cable catalog
numbers, system performance specifications, and the optimum torque/speed curves.
IMPORTANT When using Kinetix 6000 (series B) drives, configured for enhanced peak performance, you can usually achieve full motor
performance with a smaller drive. Kinetix 6200 and Kinetix 6500 drives are configured for enhanced peak performance by
default. Expect the same peak performance from Kinetix 6200 and Kinetix 6500 drives as Kinetix 6000 (series B) drives
configured for enhanced peak performance.
Refer to Kinetix 6000 IAM/AM Module Series Change on page 276 for more Kinetix 6000 enhanced-peak information.
Bulletin MPS Motor Performance Specifications with Kinetix 6200/6500 (460V) Drives
System System System Peak System Peak Motor Rated Kinetix 6200/
Max Speed Continuous Continuous
Rotary Motor Stall Current Stall Torque Output Kinetix 6500
rpm Stall Current Stall Torque
A 0-pk N•m (lb•in) kW 460V Drives
A 0-pk N•m (lb•in)
4.0 3.0 (26.5) 9.90 6.6 (58.4) 2094-BMP5-M
MPS-B330P 5000 1.3
4.9 3.6 (32) 19.0 11.0 (97.2) 2094-BM01-M
21.5 22.8 (202) 2094-BM01-M
MPS-B4540F 3000 7.1 8.1 (72) 1.4
26.0 27.1 (240) 2094-BM02-M
MPS-B560F 3000 17.0 21.5 (190) 68.0 67.8 (600) 3.5 2094-BM03-M
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 5.000 or later.
Bulletin MPS Motor Performance Specifications with Kinetix 6000 (460V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 6000
Rotary Motor Stall Current Stall Torque Output
rpm Stall Current Stall Torque 460V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
13.0 8.2 (72.5) 2094-BM01-S @ 150%
MPS-B330P 5000 4.9 3.60 (32) 1.3
19.0 11.0 (97.2) 2094-BM01-S @ 250%
21.5 22.8 (202) 2094-BM01-S @ 250%
MPS-B4540F 3000 7.1 8.1 (72) 21.8 23.2 (205) 1.4 2094-BM02-S @ 150%
26.0 27.1 (240) 2094-BM02-S @ 250%
45.0 49.2 (435) 2094-BM03-S @ 150%
MPS-B560F 3000 17.0 21.5 (190) 3.5
68.0 67.8 (600) 2094-BM03-S @ 250%
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 5.000 or later.
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives/MP-Series Stainless Steel Motor Curves
2094-BM01-S @ 250% or 2094-BM01-M 2094-BM02-S @ 250% or 2094-BM02-M
and MPS-B330P and MPS-B4540F
Torque 12.0 106 Torque Torque 30 265 Torque
(N•m) (lb•in) (N•m) (lb•in)
10.0 88.5 25 221
0 0 0 0
0 1000 2000 3000 4000 5000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
50 442
40 354
30 265
20 177
10 88.5
0 0
= Intermittent operating region
0 500 1000 1500 2000 2500 3000 = Continuous operating region
Speed (rpm) = Drive operation with 400V AC (rms) input voltage
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives with RDD-Series Direct Drive Motors
This section provides system combination information for the Kinetix 6000 and Kinetix 6200/6500 (460V) drives when
matched with RDD-Series direct drive motors. Included are motor power/brake and feedback cable catalog numbers,
system performance specifications, and the optimum torque/speed curves.
IMPORTANT When using Kinetix 6000 (series B) drives, configured for enhanced peak performance, you can usually achieve full motor
performance with a smaller drive. Kinetix 6200 and Kinetix 6500 drives are configured for enhanced peak performance by
default. Expect the same peak performance from Kinetix 6200 and Kinetix 6500 drives as Kinetix 6000 (series B) drives
configured for enhanced peak performance.
Refer to Kinetix 6000 IAM/AM Module Series Change on page 276 for more Kinetix 6000 enhanced-peak information.
2090-CPWM7DF-08AAxx (standard)
RDB-B29029, RDB-B41016, RDB-B41024 2090-CPWM7DF-08AFxx (continuous-flex)
(1) For Kinetix 6200/6500 drives, use low-profile connector kit (catalog number 2090-K6CK-D15M) or panel-mounted breakout components on the drive end.
For Kinetix 6000 drives, use low-profile feedback module (catalog number 2090-K6CK-KENDAT). Refer to Breakout Components and Connector Kits beginning on page 442.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin RDB Motor Performance Specifications with Kinetix 6200/6500 (460V) Drives
System System System Peak System Peak Motor Rated Kinetix 6200/
Max Speed Continuous Continuous
Rotary Motor Stall Current Stall Torque Output Kinetix 6500
rpm Stall Current Stall Torque
A 0-pk N•m (lb•in) kW 460V Drives
A 0-pk N•m (lb•in)
RDB-B21519 1235 10.3 31.2 (276) 27.3 83.1 (735) 3.64 2094-BM02-M
RDB-B2151C 2125 17.3 31.3 (277) 46.4 82.8 (733) 5.23 2094-BM03-M
RDB-B21529 1035 12.2 43.4 (384) 32.8 111 (982) 4.33 2094-BM02-M
RDB-B2152C 2125 23.5 43.4 (384) 63.2 111 (982) 6.41 2094-BM03-M
RDB-B21539 1250 15.8 51.5 (456) 47.9 137 (1212) 5.34 2094-BM03-M
RDB-B2153C 2250 29.4 51.5 (456) 82.6 137 (1212) 5.87 2094-BM03-M
RDB-B29014 450 5.9 48.9 (433) 17.6 110 (973) 1.97 2094-BM01-M
RDB-B29016 785 10.0 48.9 (433) 31.0 110 (973) 3.18 2094-BM02-M
RDB-B29019 1500 20.0 48.9 (167) 58.7 110 (973) 3.63 2094-BM03-M
RDB-B29024 435 11.0 97.8 (865) 33.0 214 (1894) 3.33 2094-BM02-M
RDB-B29026 885 22.3 97.8 (865) 67.2 214 (1894) 4.05 2094-BM03-M
RDB-B29029 1200 40.0 97.5 (863) 97.8 195 (1726) 4.05 2094-BM05-M
RDB-B29034 500 18.2 140 (1239) 56.6 321 (2841) 5.16 2094-BM03-M
RDB-B29036 750 27.0 140 (1239) 84.9 318 (2814) 5.49 2094-BM05-M
RDB-B29039 1000 48.9 113 (1000) 97.8 194 (1717) 4.41 2094-BM05-M
RDB-B41014 385 18.3 183 (1619) 51.2 340 (3009) 5.20 2094-BM03-M
RDB-B41016 700 33.8 183 (1619) 95.5 339 (3000) 4.83 2094-BM05-M
RDB-B41018 700 48.9 175 (1549) 97.8 271 (2398) 4.83 2094-BM05-M
RDB-B41024 365 31.5 330 (2929) 95.5 690 (6107) 7.29 2094-BM05-M
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 5.000 or later.
Bulletin RDB Motor Performance Specifications with Kinetix 6000 (460V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 6000
Rotary Motor Stall Current Stall Torque Output
rpm Stall Current Stall Torque 460V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
21.8 66.8 (591) 2094-BM02-S @ 150%
RDB-B21519 1235 10.3 31.2 (276) 3.64
27.3 83.1 (735) 2094-BM02-S @ 250%
45.0 80.2 (710) 2094-BM03-S @ 150%
RDB-B2151C 2125 17.3 31.3 (277) 5.23
46.4 82.8 (733) 2094-BM03-S @ 250%
21.8 76.8 (680) 2094-BM02-S @ 150%
RDB-B21529 1035 12.2 43.4 (384) 4.33
32.8 111 (982) 2094-BM02-S @ 250%
45.0 80.4 (711) 2094-BM03-S @ 150%
RDB-B2152C 2125 23.5 43.4 (384) 6.41
63.2 111 (982) 2094-BM03-S @ 250%
45.0 130 (1150) 2094-BM03-S @ 150%
RDB-B21539 1250 15.8 51.5 (456) 5.34
47.9 137 (1212) 2094-BM03-S @ 250%
75.0 125 (1106) 2094-BM03-S @ 250%
RDB-B2153C 2250 29.4 51.5 (456) 73.4 122 (1080) 5.87 2094-BM05-S @ 150%
82.6 137 (1212) 2094-BM05-S @ 200%
13.0 89.2 (789) 2094-BM01-S @ 150%
RDB-B29014 450 5.9 48.9 (167) 1.97
17.6 110 (973) 2094-BM01-S @ 250%
21.8 86.6 (766) 2094-BM02-S @ 150%
RDB-B29016 785 10.0 48.9 (167) 3.18
31.0 110 (973) 2094-BM02-S @ 250%
45.0 90.8 (803) 2094-BM03-S @ 150%
RDB-B29019 1500 20.0 48.9 (167) 3.63
58.7 110 (973) 2094-BM03-S @ 250%
21.8 159 (1407) 2094-BM02-S @ 150%
RDB-B29024 435 11.0 97.8 (865) 3.33
33.0 214 (1894) 2094-BM02-S @ 250%
45.0 161 (1425) 2094-BM03-S @ 150%
RDB-B29026 885 22.3 97.8 (865) 4.05
67.2 214 (1894) 2094-BM03-S @ 250%
RDB-B29029 1200 40.0 97.5 (863) 97.8 195 (1726) 4.05 2094-BM05-S @ 200%
45.0 274 (2425) 2094-BM03-S @ 150%
RDB-B29034 500 18.2 140 (1239) 5.16
56.6 321 (2841) 2094-BM03-S @ 250%
73.4 290 (2566) 2094-BM05-S @ 150%
RDB-B29036 750 27.0 140 (1239) 5.49
84.9 318 (2814) 2094-BM05-S @ 200%
RDB-B29039 1000 48.9 113 (1000) 97.8 194 (1717) 4.41 2094-BM05-S @ 200%
45.0 317 (2805) 2094-BM03-S @ 150%
RDB-B41014 385 18.3 183 (1619) 5.20
51.2 340 (3009) 2094-BM03-S @ 250%
73.4 292 (2584) 2094-BM05-S @ 150%
RDB-B41016 700 33.8 183 (1619) 4.83
95.5 339 (3000) 2094-BM05-S @ 200%
RDB-B41018 700 48.9 175 (1549) 97.8 271 (2398) 4.83 2094-BM05-S @ 200%
73.4 593 (5248) 2094-BM05-S @ 150%
RDB-B41024 365 31.5 330 (2929) 7.29
95.5 690 (6107) 2094-BM05-S @ 200%
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 5.000 or later.
Kinetix 6000 (460V) Drives with RDD-Series Direct Drive Motor Curves
80 708 80 708
60 531 60 531
40 354 40 354
20 177 20 177
0 0 0 0
0 250 500 750 1000 1250 1500 0 500 1000 1500 2000 2500
Speed (rpm) Speed (rpm)
75 664 75 664
50 442 50 442
25 221 25 221
0 0 0 0
0 250 500 750 1000 1250 1500 0 500 1000 1500 2000 2500
Speed (rpm) Speed (rpm)
80 708 80 708
60 531 60 531
40 354 40 354
20 177 20 177
0 0 0 0
0 250 500 750 1000 1250 1500 0 500 1000 1500 2000 2500
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
Kinetix 6000 (460V) Drives with RDD-Series Direct Drive Motor Curves, Continued
2094-BM01-S @ 250% or 2094-BM01-M 2094-BM02-S @ 250% or 2094-BM02-M
and RDB-B29014 and RDB-B29016
Torque 125 1106 Torque Torque 125 1106 Torque
(N•m) (lb•in) (N•m) (lb•in)
75 664 75 664
50 442 50 442
25 221 25 221
0 0 0 0
0 100 200 300 400 500 0 200 400 600 800 1000
Speed (rpm) Speed (rpm)
25 221 50 442
0 0 0 0
0 250 500 750 1000 1250 1500 0 100 200 300 400 500
Speed (rpm) Speed (rpm)
50 442 50 442
0 0 0 0
0 200 400 600 800 1000 0 250 500 750 1000 1250 1500
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
Kinetix 6000 (460V) Drives with RDD-Series Direct Drive Motor Curves, Continued
2094-BM03-S @ 250% or 2094-BM03-M 2094-BM05-S @ 200% or 2094-BM05-M
and RDB-B29034 and RDB-B29036
Torque 350 3098 Torque Torque 350 3098 Torque
(N•m) (lb•in) (N•m) (lb•in)
300 2655 300 2655
50 442 50 442
0 0 0 0
0 100 200 300 400 500 200 400 600 800 1000
Speed (rpm) Speed (rpm)
150 1328
140 1239
100 885
70 619
50 442
0 0 0 0
0 100 200 300 400 500 0 200 400 600 800 1000
Speed (rpm) Speed (rpm)
500 4425
400 3540
300 2655
200 1770
100 885
0 0
0 100 200 300 400 500
Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
(1) Use low-profile connector kit (catalog number 2090-K6CK-D15M) or panel-mounted breakout components on drive end. Refer to Breakout Components and Connector Kits
beginning on page 442 for more information.
TL-Series (Bulletin TLY-Axxx) motors are characterized as having 1000 mm (39.4 in.) cable extensions with circular plastic connectors.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin TLY (non-brake) Motor Performance Specifications with Kinetix 6000 (230V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 6000
Rotary Motor Stall Current Torque Output
rpm Stall Current Stall Torque 230V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
TLY-A110T 0.55 0.096 (0.85) 1.50 0.20 (1.75) 0.041 2094-AMP5-S
TLY-A120T 1.03 0.181 (1.60) 2.50 0.36 (3.20) 0.086 2094-AMP5-S
TLY-A130T 1.85 0.325 (2.88) 4.90 0.76 (6.70) 0.14 2094-AMP5-S
6000
TLY-A220T 3.50 0.836 (7.40) 7.90 1.48 (13.1) 0.35 2094-AMP5-S
5.20 1.23 (10.9) 10.5 2.07 (18.3) 2094-AMP5-S
TLY-A230T 0.44
5.50 1.30 (11.5) 15.5 3.05 (27.0) 2094-AM01-S
8.50 2.20 (19.5) 17.0 4.18 (37.0) 2094-AM01-S
TLY-A2530P 0.69
10.0 2.60 (23.0) 21.0 5.20 (46.0) 2094-AM02-S
5000
8.50 2.48 (22.0) 17.0 4.97 (44.0) 2094-AM01-S
TLY-A2540P 0.86
10.0 2.94 (26.0) 24.8 7.10 (63.0) 2094-AM02-S
TLY-A310M 4500 10.0 3.61 (31.9) 30.0 9.0 (79.6) 0.95 2094-AM02-S
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
Bulletin TLY (brake) Motor Performance Specifications with Kinetix 6000 (230V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 6000
Rotary Motor Stall Current Torque Output
rpm Stall Current Stall Torque 230V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
TLY-A110T 0.50 0.086 (0.76) 1.50 0.20 (1.75) 0.037 2094-AMP5-S
TLY-A120T 0.93 0.163 (1.44) 2.50 0.36 (3.20) 0.077 2094-AMP5-S
TLY-A130T 1.67 0.293 (2.59) 4.90 0.76 (6.70) 0.13 2094-AMP5-S
6000
TLY-A220T 3.15 0.757 (6.70) 7.90 1.48 (13.1) 0.24 2094-AMP5-S
4.95 1.16 (10.3) 10.5 2.07 (18.3) 2094-AMP5-S
TLY-A230T 0.32
4.95 1.16 (10.3) 15.5 3.05 (27.0) 2094-AM01-S
8.50 2.20 (19.5) 17.0 4.18 (37.0) 2094-AM01-S
TLY-A2530P 0.55
10.0 2.60 (23.0) 21.0 5.20 (46.0) 2094-AM02-S
5000
8.50 2.48 (22.0) 17.0 4.97 (44.0) 2094-AM01-S
TLY-A2540P 0.66
10.0 2.94 (26.0) 24.8 7.10 (63.0) 2094-AM02-S
TLY-A310M 4500 10.0 3.61 (31.9) 30.0 9.0 (79.6) 0.90 2094-AM02-S
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) = Intermittent operating region Speed (rpm)
= Continuous operating region
IMPORTANT The MP-Series low-inertia motors on this page are equipped with DIN connectors (specified by 4 or 7 in the catalog
number) and are not compatible with cables designed for motors equipped with bayonet connectors (specified by 2 in
the catalog number). The motors with bayonet connectors (for example, MPL-A310P-xx2xAA) are being discontinued
and require 2090-XXNxMP (bayonet) cables. For help with migration or to select bayonet cables, contact your
Rockwell Automation sales representative.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
0 0 0 0
0 2000 4000 6000 8000 0 2000 4000 6000 8000
Speed (rpm) Speed (rpm)
0 0 0 0
0 2000 4000 6000 8000 0 2000 4000 6000 8000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region (three-phase input)
= Continuous operating region
= Drive operation (single-phase input)
Kinetix 2000 Drives with MP-Series Low Inertia Motor Curves, Continued
0 0 0 0
0 1000 2000 3000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
5.0 44.2
3.0 26.5
1.0 8.85
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
4.0 35.4
4.0 35.4
2.0 17.7
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region (three-phase input)
= Continuous operating region
= Drive operation (single-phase input)
Kinetix 2000 Drives with MP-Series Low Inertia Motor Curves, Continued
20 177 20 177
15 133 15 133
10 88.5 10 88.5
5 44.2 5 44.2
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000
Speed (rpm) Speed (rpm)
20 177
15 133
10 88.5
5 44.2
0 0
0 250 500 750 1000 1250 1500
Speed (rpm)
= Intermittent operating region (three-phase input)
= Continuous operating region
= Drive operation (single-phase input)
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
4.0 35.4
2.0 17.7
2.0 17.7
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
20 177
15 133
10 88.5
5 44.2
0 0
0 1000 2000 3000 4000
Speed (rpm)
= Intermittent operating region (three-phase input)
= Continuous operating region
= Drive operation (single-phase input)
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
8.0 70.8
6.0 53.1
4.0 35.4
2.0 17.7
0 0
0 1000 2000 3000 4000 5000
Speed (rpm)
= Intermittent operating region (three-phase input)
= Continuous operating region
= Drive operation (single-phase input)
The TLY-Axxxx-B motors with 17-bit high resolution encoder feedback require the 2090-CFBM6DF-CBAAxx flying-lead feedback cable and 2090-K2CK-D15M connector kit
with 2090-DA-BAT2 battery.
TL-Series (Bulletin TLY) motors are characterized as having 1000 mm (39.4 in.) cable extensions with circular plastic connectors and TLY-Axxx catalog numbers.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin TLY (non-brake) Motor Performance Specifications with Kinetix 2000 Drives
System System System Peak System Peak Motor Rated Kinetix 2000
Max Speed Continuous Continuous
Rotary Motor Stall Current Torque Output IAM/AM
rpm Stall Current Stall Torque
A 0-pk N•m (lb•in) kW Module
A 0-pk N•m (lb•in)
TLY-A110x 0.55 0.096 (0.85) 1.50 0.20 (1.75) 0.041 2093-AMP1
TLY-A120x 1.03 0.181 (1.60) 2.50 0.36 (3.20) 0.086 2093-AMP1
TLY-A130x (1) 1.85 0.325 (2.88) 4.90 0.76 (6.70) 0.14 2093-AMP2
6000
TLY-A220x 3.50 0.836 (7.40) 7.90 1.48 (13.1) 0.35 2093-AMP5
TLY-A230x 5.50 1.30 (11.5) 15.5 3.05 (27.0) 0.44 2093-AM01
TLY-A2530P 10.0 2.60 (23.0) 21.0 5.20 (46.0) 0.69 2093-AM02
5000
TLY-A2540P 10.0 2.94 (26.0) 24.8 7.10 (63.0) 0.86 2093-AM02
TLY-A310M 4500 10.0 3.61 (31.9) 30.0 9.0 (79.6) 0.95 2093-AM02
(1) Applies to TLY-AxxxT-H motors with incremental feedback. The TLY-AxxxP-B motors with absolute high-resolution encoders are rated at 5000 rpm.
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
Bulletin TLY (brake) Motor Performance Specifications with Kinetix 2000 Drives
System System System Peak System Peak Motor Rated Kinetix 2000
Max Speed Continuous Continuous
Rotary Motor Stall Current Torque Output IAM/AM
rpm Stall Current Stall Torque
A 0-pk N•m (lb•in) kW Module
A 0-pk N•m (lb•in)
TLY-A110x 0.50 0.086 (0.76) 1.50 0.20 (1.75) 0.037 2093-AMP1
TLY-A120x 0.93 0.163 (1.44) 2.50 0.36 (3.20) 0.077 2093-AMP1
TLY-A130x (1) 1.67 0.293 (2.59) 4.90 0.76 (6.70) 0.13 2093-AMP2
6000
TLY-A220x 3.15 0.757 (6.70) 7.90 1.48 (13.1) 0.24 2093-AMP5
TLY-A230x 4.95 1.16 (10.3) 15.5 3.05 (27.0) 0.32 2093-AM01
TLY-A2530P 10.0 2.60 (23.0) 21.0 5.20 (46.0) 0.55 2093-AM02
5000
TLY-A2540P 10.0 2.94 (26.0) 24.8 7.10 (63.0) 0.66 2093-AM02
TLY-A310M 4500 10.0 3.61 (31.9) 30.0 9.0 (79.6) 0.90 2093-AM02
(1) Applies to TLY-AxxxT-H motors with incremental feedback. The TLY-AxxxP-B motors with absolute high-resolution encoders are rated at 5000 rpm.
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0.300 Intermittent curve represents 2.65 0.300 Intermittent curve represents 2.65
three-phase and single-phase inputs. three-phase and single-phase inputs.
0.250 2.21 0.250 2.21
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) = Intermittent operating region (three-phase input) Speed (rpm)
= Continuous operating region
= Drive operation (single-phase input)
0.600 Intermittent curve represents 5.31 0.600 Intermittent curve represents 5.31
three-phase and single-phase inputs. three-phase and single-phase inputs.
0.500 4.42 0.500 4.42
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
2.50 Intermittent curve represents 22.1 2.50 Intermittent curve represents 22.1
three-phase and single-phase inputs. three-phase and single-phase inputs.
2.00 17.7 2.00 17.7
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region (three-phase input)
= Continuous operating region
= Drive operation (single-phase input)
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
0.300 Intermittent curve represents 2.65 0.300 Intermittent curve represents 2.65
three-phase and single-phase inputs. three-phase and single-phase inputs.
0.250 2.21 0.250 2.21
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
0.600 Intermittent curve represents 5.31 0.600 Intermittent curve represents 5.31
three-phase and single-phase inputs. three-phase and single-phase inputs.
0.500 4.42 0.500 4.42
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
= Intermittent operating region (three-phase input)
= Continuous operating region
= Drive operation (single-phase input)
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
2.50 Intermittent curve represents 22.1 2.50 Intermittent curve represents 22.1
three-phase and single-phase inputs. three-phase and single-phase inputs.
2.00 17.7 2.00 17.7
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
= Intermittent operating region (three-phase input)
= Continuous operating region
= Drive operation (single-phase input)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region (three-phase input)
= Continuous operating region
= Drive operation (single-phase input)
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
IMPORTANT The MP-Series low-inertia motors on this page are equipped with DIN connectors (specified by 7 in the catalog
number) and are not compatible with cables designed for motors equipped with bayonet connectors (specified by 2 in
the catalog number). The motors with bayonet connectors (for example, MPL-A310P-xx2xAA) are being discontinued
and require 2090-XXNxMP (bayonet) cables. For help with migration or to select bayonet cables, contact your
Rockwell Automation sales representative.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin MPL Motor Performance Specifications with Kinetix 7000 (460V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 7000
Rotary Motor Stall Current Stall Torque Output
rpm Stall Current Stall Torque Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
MPL-B540K 3000 20.4 19.5 (172) 60.0 48.6 (430) 5.4 2099-BM06-S
MPL-B560F 3000 20.9 27.0 (239) 68.0 67.7 (599) 5.5 2099-BM06-S
MPL-B580F 3000 26.0 34.0 (301) 94.0 87.0 (770) 7.1 2099-BM06-S
MPL-B580J 3800 32.0 34.0 (301) 94.0 81.0 (717) 7.9 2099-BM06-S
MPL-B640F 3000 27.8 36.7 (325) 65.0 72.3 (640) 6.1 2099-BM06-S
MPL-B660F 3000 33.0 48.0 (425) 96.0 101 (894) 6.1 2099-BM06-S
MPL-B680D 2000 29.4 62.8 (556) 94.0 154 (1363) 9.3 2099-BM06-S
MPL-B680F 3000 41.5 59.4 (526) 96.0 108 (956) 7.5 2099-BM06-S
MPL-B860D 2000 40.9 83.1 (735) 95.5 152 (1345) 12.5 2099-BM06-S
108 (956) 96.0 200 (1796) 2099-BM06-S
MPL-B880C 1500 41.1 12.6
109 (965) 97.5 203 (1770) 2099-BM07-S
57.0 92.5 (818) 2099-BM06-S
MPL-B880D 2000 96.0 147 (1301) 12.6
58.0 110 (973) 2099-BM07-S
MPL-B960B 1200 36.8 130 (1150) 94.0 231 (2044) 12.7 2099-BM06-S
96.0 184 (1628) 2099-BM06-S
MPL-B960C 1500 47.6 124 (1097) 113 209 (1850) 14.8 2099-BM07-S
125 226 (2000) 2099-BM08-S
57.0 100 (885) 96.0 171 (1513) 2099-BM06-S
MPL-B960D 2000 113 201 (1779) 15.0 2099-BM07-S
60.6 124 (1097)
125 223 (1973) 2099-BM08-S
MPL-B980B 1000 34.6 162 (1434) 94.0 278 (2460) 15.2 2099-BM06-S
57.0 131 (1159) 96.0 198 (1752) 2099-BM06-S
MPL-B980C 1500 113 227 (2009) 16.8 2099-BM07-S
59.0 158 (1398)
140 270 (2389) 2099-BM08-S
57.0 113 (1000) 96.0 183 (1619) 2099-BM06-S
MPL-B980D 2000 148 (1310) 113 213 (1885) 18.6 2099-BM07-S
68.4
158 (1398) 140 259 (2292) 2099-BM08-S
MPL-B980E 2750 105 141 (1250) 218 237 (2100) 13.0 2099-BM09-S
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
30 265
20 177
20 177
10 88.5
10 88.5
0 0 0 0
0 1000 2000 3000 4000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
60 531 60 531
40 354 40 354
20 177 20 177
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
20 177 20 177
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
80 708 60 531
60 531 40 354
40 354
20 177
20 177
0 0 0 0
0 500 1000 1500 2000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
40 354
50 442
20 177
0 0 0
0 500 1000 1500 2000 0 250 500 750 1000 1250 1500
Speed (rpm) Speed (rpm)
40 354
50 442
20 177
0 0 0 0
0 500 1000 1500 2000 0 300 600 900 1200
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
50 442 50 442
0 0 0
0 250 500 750 1000 1250 1500 0 500 1000 1500 2000
Speed (rpm) Speed (rpm)
50 442 50 442
0 0 0 0
0 200 400 600 800 1000 0 250 500 750 1000 1250 1500
Speed (rpm) Speed (rpm)
50 442 50 442
0 0 0 0
0 400 800 1200 1600 2000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
MPM-B1653F
2090-CPxM7DF-08AAxx (standard)
MPM-B2152F, MPM-B2152M, MPM-B2153E, MPM-B2153F, 2090-CPxM7DF-08AFxx (continuous-flex)
MPM-B2154B, MPM-B2154E, MPM-B2154F
(1) Use low-profile connector kit (catalog number 2090-K6CK-D15M) or panel-mounted breakout components on drive end. Refer to Breakout Components and Connector Kits
beginning on page 442.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin MPM Motor Performance Specifications with Kinetix 7000 (460V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 7000
Rotary Motor Stall Current Stall Torque Output
rpm Stall Current Stall Torque Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
MPM-B1651M 5000 25.8 11.3 (100) 56.8 21.4 (189) 2.50 2099-BM06-S
MPM-B1652E 3500 24.0 21.1 (187) 60.5 48.0 (425) 4.30 2099-BM06-S
MPM-B1652F 4500 33.0 21.1 (187) 84.1 45.0 (398) 4.30 2099-BM06-S
MPM-B1653C 2500 23.0 26.7 (236) 59.2 67.7 (599) 4.60 2099-BM06-S
MPM-B1653E 3500 31.0 26.8 (237) 72.9 62.0 (549) 5.10 2099-BM06-S
MPM-B1653F 4000 40.1 31.0 (274) 94.3 56.1 (496) 5.10 2099-BM06-S
MPM-B2152C 2500 31.5 36.7 (325) 55.4 72.2 (639) 5.60 2099-BM06-S
96.0 70.8 (626) 2099-BM06-S
MPM-B2152F 4500 50.0 34.1 (302) 5.90
98.0 72.2 (639) 2099-BM07-S
MPM-B2152M 5000 51.2 34.1 (302) 76.3 52.9 (468) 5.90 2099-BM06-S
MPM-B2153B 2000 27.6 48.0 (425) 60.0 101 (895) 6.80 2099-BM06-S
96.0 98.8 (468) 2099-BM06-S
MPM-B2153E 3000 45.5 47.9 (424) 7.20
98.6 101 (895) 2099-BM07-S
96.0 96.6 (855) 2099-BM06-S
MPM-B2153F 3800 50.4 45.6 (403) 7.20
98.4 98.9 (875) 2099-BM07-S
96.0 151 (1336) 2099-BM06-S
MPM-B2154B 2000 40.7 62.7 (555) 6.90
98.0 154 (1363) 2099-BM07-S
96.0 110 (973) 2099-BM06-S
MPM-B2154E 3000 50.2 55.9 (495) 7.50
98.3 112 (991) 2099-BM07-S
MPM-B2154F 3300 51.0 56.2 (497) 83.6 87.9 (778) 7.50 2099-BM06-S
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
16.0 30 265
142
12.0 106
20 177
8.0 70.8
10 88.5
4.0 35.4
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
30.0 265
20 177
20.0 177
10 88.5
10.0 88.5
0 0 0 0
0 1000 2000 3000 4000 5000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
80 708 80 708
60 531 60 531
40 354 40 354
20 177 20 177
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 500 1000 1500 2000
Speed (rpm) Speed (rpm)
60 60 531
531
45 398
40 354
30 265
20 177
15 133
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
75 664
50 442
50 442
25 221
25 221
0 0 0 0
0 500 1000 1500 2000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
80 708
60 531
40 354
20 177
0 0
0 1000 2000 3000 4000
Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
RDB-B2152C
2090-CPxM7DF-12AAxx (standard) 2090-XXNFMF-Sxx (standard)
RDB-B29026 2090-CFBM7DF-CDAFxx (continuous-flex)
Absolute High-resolution Feedback
RDB-B2151F, RDB-B2153C 2090-CPxM7DF-10AAxx (standard)
RDB-B29036, RDB-B41014 2090-CPxM7DF-10AFxx (continuous-flex)
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin RDB Motor Performance Specifications with Kinetix 7000 (460V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 7000
Rotary Motor Stall Current Stall Torque Output
rpm Stall Current Stall Torque 460V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
RDB-B2152C 2125 23.5 43.4 (384) 63.2 111 (982) 6.41 2099-BM06-S
RDB-B2153C 2250 29.4 51.5 (456) 82.6 137 (1212) 5.87 2099-BM06-S
96.0 193 (1708) 2099-BM06-S
RDB-B29029 1200 40.0 97.5 (863) 4.05
111 214 (1894) 2099-BM07-S
RDB-B29036 750 27.0 140 (1239) 84.9 318 (2814) 5.49 2099-BM06-S
RDB-B29039 1000 52.7 122 (1080) 147 268 (2372) 4.41 2099-BM08-S
RDB-B41016 700 33.8 183 (1619) 95.5 339 (3000) 4.83 2099-BM06-S
113 299 (2646) 2099-BM07-S
RDB-B41018 700 51.3 183 (1619) 4.83
140 339 (3000) 2099-BM08-S
RDB-B41024 365 31.5 330 (2929) 95.5 690 (6107) 7.29 2099-BM06-S
147 626 (5540) 2099-BM08-S
RDB-B41026 600 52.0 308 (2726) 7.29
218 688 (6089) 2099-BM09-S
147 897 (7939) 2099-BM08-S
RDB-B41035 490 52.6 425 (3761) 8.69
218 1050 (9293) 2099-BM09-S
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
Kinetix 7000 (460V) Drives with RDD-Series Direct Drive Motor Curves
2099-BM06-S and RDB-B2152C 2099-BM06-S and RDB-2153C
Torque 125 1106 Torque Torque 140 1239 Torque
(N•m) (lb•in) (N•m) (lb•in)
120 1062
100 885
100 885
75 664 80 708
60 531
50 442
40 354
25 221
20 177
0 0 0 0
0 500 1000 1500 2000 2500 0 500 1000 1500 2000 2500
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
Kinetix 7000 (460V) Drives with RDD-Series Direct Drive Motor Curves, Continued
150 1327
100 885
100 885
50 442
50 442
0 0 0 0
0 250 500 750 1000 1250 1500 0 200 400 600 800 1000
Speed (rpm) Speed (rpm)
150 1327
120 1062
100 885
60 531
50 442
0 0 0 0
0 200 400 600 800 1000 0 200 400 600 800 1000
Speed (rpm) Speed (rpm)
150 1327
300 2655
100 885
150 1327
50 442
0 0 0 0
0 200 400 600 800 1000 0 100 200 300 400 500
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
Kinetix 7000 (460V) Drives with RDD-Series Direct Drive Motor Curves, Continued
0 0 0 0
0 100 200 300 400 500 0 100 200 300 400 500 600
Speed (rpm) Speed (rpm)
1000 8851
750 6638
500 4425
250 2212
0 0
0 100 200 300 400 500
Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
IMPORTANT The MP-Series low-inertia motors on this page are equipped with DIN connectors (specified by 4 or 7 in the catalog
number) and are not compatible with cables designed for motors equipped with bayonet connectors (specified by 2 in
the catalog number). The motors with bayonet connectors (for example, MPL-A310P-xx2xAA) are being discontinued
and require 2090-XXNxMP (bayonet) cables. For help with migration or to select bayonet cables, contact your
Rockwell Automation sales representative.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin MPL Motor Performance Specifications with Kinetix 300 (240V) Drives
System System System Peak System Peak Motor Rated
Rotary Motor Max Speed (1) Continuous Continuous Stall Current Stall Torque Output Kinetix 300
rpm Stall Current Stall Torque 240V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
MPL-A1510V 5000 1.05 0.26 (2.3) 3.40 0.77 (6.8) 0.16 2097-V33PR1
MPL-A1520U 5000 1.80 0.49 (4.3) 6.10 1.58 (13.9) 0.27 2097-V33PR1
MPL-A1530U 5000 2.82 0.90 (8.0) 10.1 2.82 (24.9) 0.39 2097-V33PR3
MPL-A210V 5000 3.09 0.55 (4.8) 10.2 1.52 (13.5) 0.37 2097-V33PR3
MPL-A220T 5000 4.54 1.61 (14.2) 15.5 4.74 (41.9) 0.62 2097-V33PR3
MPL-A230P 5000 5.40 2.10 (18) 23.0 8.2 (72.5) 0.86 2097-V33PR5
MPL-A310F 3000 3.20 1.58 (14) 9.3 3.61 (32) 0.46 2097-V33PR3
MPL-A310P 5000 4.85 1.58 (14) 14 3.61 (32) 0.73 2097-V33PR3
MPL-A320H 3500 6.1 3.05 (27) 19.3 7.91 (70) 1.0 2097-V33PR5
MPL-A320P 5000 9.0 3.05 (27) 29.5 7.91 (70) 1.3 2097-V33PR5
MPL-A330P 5000 12.0 4.18 (37) 38 11.1 (98) 1.8 2097-V33PR6
MPL-A420P 5000 12.7 4.74 (42) 46 13.5 (120) 2.0 2097-V33PR6
MPL-A430H 3500 12.2 6.21 (55) 45 19.8 (175) 1.8 2097-V33PR6
MPL-A430P 5000 16.8 5.99 (53) 51 15.7 (139) 2.2 2097-V33PR6
MPL-A4530F 2800 13.4 8.36 (74) 42 20.3 (180) 1.9 2097-V33PR6
(1) Maximum speed for rotary motors paired with Kinetix 300 drives is 5000 rpm.
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient, and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
0 0 0 0
0 2000 4000 6000 8000 0 2000 4000 6000 8000
Speed (rpm) Speed (rpm)
0 0 0 0
0 2000 4000 6000 8000 0 2000 4000 6000 8000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
0 0 0 0
0 1000 2000 3000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
4.0 35.4
4.0 35.4
2.0 17.7
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
5 44.2 5 44.2
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
IMPORTANT The MP-Series low-inertia motors on this page are equipped with DIN connectors (specified by 4 or 7 in the catalog
number) and are not compatible with cables designed for motors equipped with bayonet connectors (specified by 2 in
the catalog number). The motors with bayonet connectors (for example, MPL-A310P-xx2xAA) are being discontinued
and require 2090-XXNxMP (bayonet) cables. For help with migration or to select bayonet cables, contact your
Rockwell Automation sales representative.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin MPL Motor Performance Specifications with Kinetix 300 (480V) Drives
System System System Peak System Peak Motor Rated
Rotary Motor Max Speed (1) Continuous Continuous Stall Current Stall Torque Output Kinetix 300
rpm Stall Current Stall Torque 480V Drives
A (0-pk) N•m (lb•in) kW
A (0-pk) N•m (lb•in)
MPL-B1510V 5000 0.95 0.26 (2.3) 3.10 0.77 (6.80) 0.16 2097-V34PR3
MPL-B1520U 5000 1.80 0.49 (4.3) 6.10 1.58 (13.9) 0.27 2097-V34PR3
MPL-B1530U 5000 2.0 0.90 (8.0) 7.20 2.82 (24.9) 0.39 2097-V34PR3
MPL-B210V 5000 1.75 0.55 (4.8) 5.80 1.52 (13.5) 0.37 2097-V34PR3
MPL-B220T 5000 3.30 1.61 (14.2) 11.3 4.74 (41.9) 0.62 2097-V34PR5
MPL-B230P 5000 2.60 2.10 (18.6) 11.3 8.20 (73.0) 0.86 2097-V34PR5
MPL-B310P 5000 2.4 1.58 (14) 7.1 3.61 (32) 0.77 2097-V34PR3
MPL-B320P 5000 4.5 2.94 (26) 14.0 7.91 (70) 1.5 2097-V34PR5
MPL-B330P 5000 6.1 4.18 (37) 19.0 11.1 (98) 1.8 2097-V34PR6
MPL-B420P 5000 6.4 4.74 (42) 22.0 13.5 (120) 1.9 2097-V34PR6
MPL-B4530F 3000 6.7 8.36 (74) 21.0 20.3 (180) 2.1 2097-V34PR6
(1) Maximum speed for rotary motors paired with Kinetix 300 drives is 5000 rpm.
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient, and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
0 0 0 0
0 2000 4000 6000 8000 0 2000 4000 6000 8000
Speed (rpm) Speed (rpm)
0 0 0 0
0 2000 4000 6000 8000 0 2000 4000 6000 8000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
4.0 35.4
4.0 35.4
2.0 17.7
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
20 177
15 133
10 88.5
5 44.2
0 0
0 500 1000 1500 2000 2500 3000
Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin MPM Motor Performance Specifications with Kinetix 300 (240V) Drives
System System System Peak System Peak Motor Rated
Rotary Motor Max Speed (1) Continuous Continuous Stall Current Stall Torque Output Kinetix 300
rpm Stall Current Stall Torque 240V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
MPM-A1151M 5000 10.3 2.3 (20.3) 30.5 6.6 (58.4) 0.90 2097-V33PR5
MPM-A1152F 5000 14.9 4.7 (41.6) 44.8 13.5 (119) 1.40 2097-V33PR6
(1) Maximum speed for rotary motors paired with Kinetix 300 drives is 5000 rpm.
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient, and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin MPM Motor Performance Specifications with Kinetix 300 (480V) Drives
System System System Peak System Peak Motor Rated
Rotary Motor Max Speed (1) Continuous Continuous Stall Current Stall Torque Output Kinetix 300
rpm Stall Current Stall Torque 480V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
MPM-B1151F 5000 3.1 2.3 (20.3) 9.9 6.6 (58.4) 0.75 2097-V34PR5
MPM-B1151T 5000 6.9 2.3 (20.3) 20.5 5.8 (51.3) 0.90 2097-V34PR6
MPM-B1152C 3000 4.1 5.0 (44.2) 12.4 13.5 (119) 1.20 2097-V34PR5
MPM-B1152F 5000 7.0 5.0 (44.2) 21.1 13.3 (118) 1.40 2097-V34PR6
MPM-B1153E 3500 7.1 6.5 (57.5) 21.6 19.7 (174) 1.40 2097-V34PR6
MPM-B1302F 4500 9.8 6.6 (58.4) 22.0 13.2 (117) 1.65 2097-V34PR6
MPM-B1304C 2750 8.0 10.3 (91.1) 22.3 27.1 (240) 2.00 2097-V34PR6
(1) Maximum speed for rotary motors paired with Kinetix 300 drives is 5000 rpm.
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient, and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
0 0 0 0
0 1000 2000 3000 4000 5000 0 2000 4000 6000 8000
Speed (rpm) Speed (rpm)
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
20.0 177
16.0 142
12.0 106
8.0 70.8
4.0 35.4
0 0
= Intermittent operating region
0 500 1000 1500 2000 2500 3000 = Continuous operating region
Speed (rpm) = Drive operation with 400V AC (rms) input voltage
Bulletin MPF Motor Performance Specifications with Kinetix 300 (240V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 300
Rotary Motor Stall Current Stall Torque Output
rpm Stall Current Stall Torque 240V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
MPF-A310P 5000 4.85 1.58 (14) 14 3.61 (32) 0.73 2097-V33PR3
MPF-A320H 3500 6.1 3.05 (27) 19.3 7.91 (70) 1.0 2097-V33PR5
MPF-A320P 5000 9.0 3.05 (27) 29.5 7.91 (70) 1.3 2097-V33PR3
MPF-A330P 5000 12.0 4.18 (37) 38 11.1 (98) 1.6 2097-V33PR6
MPF-A430H 3500 12.2 6.21 (55) 45 19.8 (175) 1.8 2097-V33PR6
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient, and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
18.0 159
12.0 106
6.0 53
0 0
0 1000 2000 3000 4000
Speed (rpm)
= Intermittent operating region
= Continuous operating region
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin MPF Motor Performance Specifications with Kinetix 300 (480V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 300
Rotary Motor Stall Current Stall Torque Output
rpm Stall Current Stall Torque 480V Drives
A (0-pk) N•m (lb•in) kW
A (0-pk) N•m (lb•in)
MPF-B310P 5000 2.30 1.58 (14) 7.1 3.61 (32) 0.77 2097-V34PR3
MPF-B320P 5000 4.24 3.05 (27) 14.0 7.34 (65) 1.5 2097-V34PR5
16.9 10.0 (88) 2097-V34PR5
MPF-B330P 5000 5.70 4.18 (37) 1.6
19.0 11.1 (98) 2097-V34PR6
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient, and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
8.0 70.8
6.0 53.1
4.0 35.4
2.0 17.7
0 0
0 1000 2000 3000 4000 5000
Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin MPS Motor Performance Specifications with Kinetix 300 (240V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 300
Rotary Motor Stall Current Stall Torque Output
rpm Stall Current Stall Torque 240V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
33.9 10.1 (89.4) 2097-V33PR5
MPS-A330P 5000 9.80 3.60 (32) 1.3
38.0 11.1 (98.2) 2097-V33PR6
MPS-A4540F 3000 14.4 8.1 (72) 50.9 24.8 (219) 1.4 2097-V33PR6
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient, and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin MPS Motor Performance Specifications with Kinetix 300 (480V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 300
Rotary Motor Stall Current Stall Torque Output
rpm Stall Current Stall Torque 480V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
16.9 10.1 (89.4) 2097-V34PR5
MPS-B330P 5000 4.90 3.6 (32) 1.3
19.0 11.1 (98.2) 2097-V34PR6
MPS-B4540F 3000 7.1 8.1 (72) 25.4 26.3 (233) 1.4 2097-V34PR6
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient, and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
8.0 70.8
20 177
6.0 53.1
15 133
4.0 35.4
10 88.5
0 0 0 0
0 1000 2000 3000 4000 5000
0 500 1000 1500 2000 2500 3000
Speed (rpm)
= Intermittent operating region Speed (rpm)
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
The TLY-Axxxx-B motors with 17-bit high resolution encoder feedback require the 2090-CFBM6DF-CBAAxx flying-lead feedback cable and 2090-K2CK-D15M connector kit
with 2090-DA-BAT2 battery.
TL-Series (Bulletin TLY) motors are characterized as having 1000 mm (39.4 in.) cable extensions with circular plastic connectors and TLY-Axxx catalog numbers.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin TLY (non-brake) Motor Performance Specifications with Kinetix 300 (240V) Drives
System System System Peak System Peak Motor Rated
Rotary Motor Max Speed (1) Continuous Continuous Stall Current Torque Output Kinetix 300
rpm Stall Current Stall Torque 240V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
TLY-A110x 0.55 0.096 (0.85) 1.50 0.20 (1.75) 0.041 2097-V32PR0
TLY-A120x 1.03 0.181 (1.60) 2.50 0.36 (3.20) 0.086 2097-V32PR0
TLY-A130x 5000 1.85 0.325 (2.88) 4.90 0.76 (6.70) 0.14 2097-V32PR0
TLY-A220x 3.50 0.836 (7.40) 7.90 1.48 (13.1) 0.35 2097-V33PR1
TLY-A230x 5.50 1.30 (11.5) 15.5 3.05 (27.0) 0.44 2097-V33PR3
TLY-A2530P 10.0 2.60 (23.0) 21.0 5.20 (46.0) 0.69 2097-V33PR5
5000
TLY-A2540P 10.0 2.94 (26.0) 24.8 7.10 (63.0) 0.86 2097-V33PR5
TLY-A310M 4500 10.0 3.61 (31.9) 30.0 9.0 (79.6) 0.95 2097-V33PR5
(1) Maximum speed for rotary motors paired with Kinetix 300 drives is 5000 rpm.
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient, and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
Bulletin TLY (brake) Motor Performance Specifications with Kinetix 300 (240V) Drives
System System System Peak System Peak Motor Rated
Rotary Motor Max Speed (1) Continuous Continuous Stall Current Torque Output Kinetix 300
rpm Stall Current Stall Torque 240V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
TLY-A110x 0.50 0.086 (0.76) 1.50 0.20 (1.75) 0.037 2097-V32PR0
TLY-A120x 0.93 0.163 (1.44) 2.50 0.36 (3.20) 0.077 2097-V32PR0
TLY-A130x 5000 1.67 0.293 (2.59) 4.90 0.76 (6.70) 0.13 2097-V32PR0
TLY-A220x 3.15 0.757 (6.70) 7.90 1.48 (13.1) 0.24 2097-V33PR1
TLY-A230x 4.95 1.16 (10.3) 15.5 3.05 (27.0) 0.32 2097-V33PR3
TLY-A2530P 10.0 2.60 (23.0) 21.0 5.20 (46.0) 0.55 2097-V33PR5
5000
TLY-A2540P 10.0 2.94 (26.0) 24.8 7.10 (63.0) 0.66 2097-V33PR5
TLY-A310M 4500 10.0 3.61 (31.9) 30.0 9.0 (79.6) 0.90 2097-V33PR5
(1) Maximum speed for rotary motors paired with Kinetix 300 drives is 5000 rpm.
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient, and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0.300 Intermittent curve represents 2.65 0.300 Intermittent curve represents 2.65
single-phase input. single-phase input.
0.250 2.21 0.250 2.21
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) = Intermittent operating region (three-phase input) Speed (rpm)
= Continuous operating region
= Drive operation (single-phase input)
0.600 Intermittent curve represents 5.31 0.600 Intermittent curve represents 5.31
single-phase input. single-phase input.
0.500 4.42 0.500 4.42
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
2.50 Intermittent curve represents 22.1 2.50 Intermittent curve represents 22.1
three-phase and single-phase inputs. three-phase and single-phase inputs.
2.00 17.7 2.00 17.7
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region (three-phase input)
= Continuous operating region
= Drive operation (single-phase input)
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
0.300 Intermittent curve represents 2.65 0.300 Intermittent curve represents 2.65
single-phase input. single-phase input.
0.250 2.21 0.250 2.21
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
0.600 Intermittent curve represents 5.31 0.600 Intermittent curve represents 5.31
single-phase input. single-phase input.
0.500 4.42 0.500 4.42
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
= Intermittent operating region (three-phase input)
= Continuous operating region
= Drive operation (single-phase input)
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
2.50 Intermittent curve represents 22.1 2.50 Intermittent curve represents 22.1
three-phase and single-phase inputs. three-phase and single-phase inputs.
2.00 17.7 2.00 17.7
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
= Intermittent operating region (three-phase input)
= Continuous operating region
= Drive operation (single-phase input)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region (three-phase input)
= Continuous operating region
= Drive operation (single-phase input)
Kinetix 3 (240V) Drives with TL-Series (Bulletin TLY) Low Inertia Motors
This section provides system combination information for the Kinetix 3 drives when matched with TL-Series
(BulletinTLY) low-inertia motors. Compatible TL-Series motors are equipped with absolute high-resolution or
incremental encoder feedback. Included are motor power/brake and feedback cable catalog numbers, system performance
specifications, and the optimum torque/speed curves.
The TLY-Axxxx-B motors with 17-bit high-resolution encoder feedback require the 2090-CFBM6DF-CBAAxx flying-lead feedback cable and 2071-TBMF breakout board with
3.6V lithium battery (customer-supplied). Refer to Battery Specifications on page 356.
TL-Series (Bulletin TLY) motors are characterized as having 1000 mm (39.4 in.) cable extensions with circular plastic connectors and TLY-Axxx catalog numbers.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Bulletin TLY (non-brake) Motor Performance Specifications with Kinetix 3 (240V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 3
Rotary Motor Stall Current Torque Output
rpm Stall Current Stall Torque 240V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
TLY-A120x 1.03 0.181 (1.60) 2.50 0.36 (3.20) 0.086 2071-AP1
TLY-A130x 1.85 0.325 (2.88) 4.90 0.76 (6.70) 0.14 2071-AP1
6000 (1)
TLY-A220x 3.50 0.836 (7.40) 7.90 1.48 (13.1) 0.35 2071-AP4
TLY-A230x 5.50 1.30 (11.5) 15.5 3.05 (27.0) 0.44 2071-AP4
TLY-A2540P 5000 10.0 2.94 (26.0) 24.8 7.10 (63.0) 0.86 2071-AP8
TLY-A310M 4500 10.0 3.61 (31.9) 30.0 9.0 (79.6) 0.95 2071-A10
(1) Applies to TLY-AxxxT-H motors with incremental feedback. The TLY-AxxxP-B motors with absolute high-resolution encoders are rated at 5000 rpm.
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 5.000 or later.
Bulletin TLY (brake) Motor Performance Specifications with Kinetix 3 (240V) Drives
System System System Peak System Peak Motor Rated
Max Speed Continuous Continuous Kinetix 3
Rotary Motor Stall Current Torque Output
rpm Stall Current Stall Torque 240V Drives
A 0-pk N•m (lb•in) kW
A 0-pk N•m (lb•in)
TLY-A120x 0.93 0.163 (1.44) 2.50 0.36 (3.20) 0.077 2071-AP1
TLY-A130x 1.67 0.293 (2.59) 4.90 0.76 (6.70) 0.13 2071-AP1
6000 (1)
TLY-A220x 3.15 0.757 (6.70) 7.90 1.48 (13.1) 0.24 2071-AP4
TLY-A230x 4.95 1.16 (10.3) 15.5 3.05 (27.0) 0.32 2071-AP4
TLY-A2540P 5000 10.0 2.94 (26.0) 24.8 7.10 (63.0) 0.66 2071-AP8
TLY-A310M 4500 10.0 3.61 (31.9) 30.0 9.0 (79.6) 0.90 2071-A10
(1) Applies to TLY-AxxxT-H motors with incremental feedback. The TLY-AxxxP-B motors with absolute high-resolution encoders are rated at 5000 rpm.
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 5.000 or later.
0.300 Intermittent curve represents 2.65 0.300 Intermittent curve represents 2.65
single-phase input. single-phase input.
0.250 2.21 0.250 2.21
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0.600 Intermittent curve represents 5.31 0.600 Intermittent curve represents 5.31
single-phase input. single-phase input.
0.500 4.42 0.500 4.42
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
1.200 Intermittent curve represents 10.6 1.200 Intermittent curve represents 10.6
single-phase input. single-phase input.
1.000 8.85 1.000 8.85
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
2.50 Intermittent curve represents 22.1 2.50 Intermittent curve represents 22.1
single-phase input. single-phase input.
2.00 17.7 2.00 17.7
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
0.300 Intermittent curve represents 2.65 0.300 Intermittent curve represents 2.65
single-phase input. single-phase input.
0.250 2.21 0.250 2.21
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
0.600 Intermittent curve represents 5.31 0.600 Intermittent curve represents 5.31
single-phase input. single-phase input.
0.500 4.42 0.500 4.42
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
1.200 Intermittent curve represents 10.6 1.200 Intermittent curve represents 10.6
single-phase input. single-phase input.
1.000 8.85 1.000 8.85
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
2.50 Intermittent curve represents 22.1 2.50 Intermittent curve represents 22.1
single-phase input. single-phase input.
2.00 17.7 2.00 17.7
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
= Intermittent operating region
Speed (rpm) Speed (rpm)
= Continuous operating region
6.00 Intermittent curve represents 53.1 6.00 Intermittent curve represents 53.1
three-phase and single-phase inputs. three-phase and single-phase inputs.
5.00 44.2 5.00 44.2
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) = Intermittent operating region Speed (rpm)
= Continuous operating region
Kinetix 3 (240V) Drives with TL-Series (Bulletin TL) Low Inertia Motors
This section provides system combination information for the Kinetix 3 servo drives when matched with TL-Series
(Bulletin TL) low-inertia motors. Bulletin TL-Axxx motors are equipped with absolute high-resolution encoder feedback
and are characterized as having 300 mm (11.8 in.) cable extensions with rectangular connectors. Included in this section are
motor power, feedback, and brake cable catalog numbers, system performance specifications, and the optimum
torque/speed curves.
TL-A410M
(1) TL-Series (Bulletin TL) rotary motors require the 2071-TBMF breakout board with 3.6V lithium battery (not included) for multi-turn high-resolution encoder operation or
when using an overtravel limit switch. To meet this requirement, remove the drive-end connector and wire the 2090-DANFCT-Sxx cable to the 2071-TBMF breakout board.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
IMPORTANT The MP-Series low-inertia motors on this page are equipped with DIN connectors (specified by 4 or 7 in the catalog
number) and are not compatible with cables designed for motors equipped with bayonet connectors (specified by 2 in
the catalog number). The motors with bayonet connectors (for example, MPL-A310P-xx2xAA) are being discontinued
and require 2090-XXNxMP (bayonet) cables. For help with migration or to select bayonet cables, contact your Rockwell
Automation sales representative.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
0 0 0 0
0 2000 4000 6000 8000 0 2000 4000 6000 8000
Speed (rpm) Speed (rpm)
0 0 0 0
0 2000 4000 6000 8000 0 2000 4000 6000 8000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
0 0 0 0
0 1000 2000 3000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
4.0 35.4
4.0 35.4
2.0 17.7
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
20 177 20 177
15 133 15 133
10 88.5 10 88.5
5 44.2 5 44.2
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
20 177 20 177
15 133 15 133
10 88.5 10 88.5
5 44.2 5 44.2
0 0 0 0
0 500 1000 1500 2000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
20 177
30 265
15 133
20 177
10 88.5
10 88.5
5 44.2
0 0 0 0
0 1000 2000 3000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
50 442
40 354
40 354
30 265
30 265
20 177
20 177
10 88.5 10 88.5
0 0 0 0
0 1000 2000 3000 4000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
IMPORTANT The MP-Series low-inertia motors on this page are equipped with DIN connectors (specified by 4 or 7 in the catalog
number) and are not compatible with cables designed for motors equipped with bayonet connectors (specified by 2 in
the catalog number). The motors with bayonet connectors (for example, MPL-A310P-xx2xAA) are being discontinued
and require 2090-XXNxMP (bayonet) cables. For help with migration or to select bayonet cables, contact your
Rockwell Automation sales representative.
0 0 0 0
0 2000 4000 6000 8000 0 2000 4000 6000 8000
Speed (rpm) Speed (rpm)
0 0 0 0
0 2000 4000 6000 8000 0 2000 4000 6000 8000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
4.0 35.4
4.0 35.4
2.0 17.7
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
20 177
15 133
15 133
10 88.5
10 88.5
5 44.2
5 44.2
0 0 0 0
0 1000 2000 3000 4000 5000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
10 88.5
10 88.5
5 44.2 5 44.2
0 0 0
0
0 1000 2000 3000 4000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
20 177
30 265
15 133
20 177
10 88.5
10 88.5
5 44.2
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
30 265 30 265
20 177 20 177
10 88.5 10 88.5
0 0 0 0
0 500 1000 1500 2000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
30 265
40 354
20 177
20 177
10 88.5
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
60 531 60 531
40 354 40 354
20 177 20 177
0 0 0 0
0 1000 2000 3000 4000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
120 1062
80 708
100 885
60 531 80 708
40 354 60 531
40 354
20 177
20 177
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000
Speed (rpm) Speed (rpm)
120 1062
80 708
100 885
60 531 80 708
40 354 60 531
40 354
20 177
20 177
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000
Speed (rpm) Speed (rpm)
80 708
100 885 60 531
40 354
50 442
20 177
0 0 0 0
0 250 500 750 1000 1250 1500 0 500 1000 1500 2000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
50 442 50 442
0 0 0 0
0 300 600 900 1200 0 250 500 750 1000 1250 1500
Speed (rpm) Speed (rpm)
200 1770
150 1328
150 1328
100 885
100 885
50 442
50 442
0 0 0 0
0 250 500 750 1000 0 250 500 750 1000 1250 1500
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
30 265 30 265
20 177 20 177
10 88.5 10 88.5
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
75 265 60 531
50 177 40 354
25 88.5 20 177
0 0 0 0
0 500 1000 1500 2000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
MPM-B1653F
2090-CPxM7DF-08AAxx (standard)
MPM-B2152F, MPM-B2152M, MPM-B2153E, MPM-B2153F, 2090-CPxM7DF-08AFxx (continuous-flex)
MPM-B2154B, MPM-B2154E, MPM-B2154F
(1) Use drive-mounted breakout board (catalog number 2090-UXBB-DM15) or panel-mounted breakout components on drive end. Refer to Breakout Components and
Connector Kits beginning on page 442.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
0 0 0 0
0 1000 2000 3000 4000 5000 0 2000 4000 6000 8000
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
0 0 0 0
0 2000 4000 6000 8000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 2000 4000 6000 8000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
0 0 0 0
0 2000 4000 6000 8000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
16.0 30 265
142
12.0 106
20 177
8.0 70.8
10 88.5
4.0 35.4
0 0 0 0
0 1000 2000 3000 4000 5000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
40 354 40 354
30 265 30 265
20 177 20 177
10 88.5 10 88.5
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
40.0 60 531
354
30.0 265
40 354
20.0 177
20 177
10.0 88.5
0 0 0 0
0 1000 2000 3000 4000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
45 398
40 354
30 265
20 177
15 133
0 0 0 0
0 500 1000 1500 2000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
75 664
40 354
50 442
20 177
25 221
0 0 0 0
0 1000 2000 3000 4000 0 500 1000 1500 2000
Speed (rpm) Speed (rpm)
75 664 60 531
50 442 40 354
25 221 20 177
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
6.0 53 6.0 53
0 0 0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
10 88
6.0 53
5 44
0 0 0 0
0 1000 2000 3000 4000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
40 354
30 266
20 176
10 88
0 0
0 1000 2000 3000 4000
Speed (rpm)
= Intermittent operating region
= Continuous operating region
4.0 35.4
5 44.2
2.0 17.7
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
10 88.5
10 88.5
5 44.2 5 44.2
0 0 0
0
0 1000 2000 3000 4000
0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
40 354
30 265
20 177
10 88.5
0 0
= Intermittent operating region
0 1000 2000 3000 4000 = Continuous operating region
Speed (rpm) = Drive operation with 400V AC (rms) input voltage
4.0 35.4 10 88
2.0 17.6 5 44
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
0 0 0 0
0 1000 2000 3000 4000 5000 0 500 1000 1500 2000 2500 3000
Speed (rpm) Speed (rpm)
50 442
40 354
30 265
20 177
10 88.5
0 0
0 500 1000 1500 2000 2500 3000
Speed (rpm)
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage
(1) Use low-profile connector kit (catalog number 2090-K6CK-D15M) or panel-mounted breakout components on drive end. Refer to Breakout Components and Connector Kits
beginning on page 442 for more information.
TL-Series (Bulletin TLY-Axxx) motors are characterized as having 1000 mm (39.4 in.) cable extensions with circular plastic connectors.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
0 0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Speed (rpm) Speed (rpm)
= Intermittent operating region
= Continuous operating region
This chapter provides the Kinetix Motion Control servo drive and actuator combinations. Each drive family/actuator
section includes:
• an actuator/cable combinations table.
• a drive/actuator performance specifications table.
• force/velocity curves with each actuator matched to the drive with optimum performance.
Performance specification data and curves reflect nominal system performance of a typical system with actuator/drive at
rated ambient temperature and line voltage. For additional information on ambients, line conditions, and valid
combinations not shown in this chapter, refer to Motion Analyzer software.
IMPORTANT This system combinations chapter does not include all possible motor/drive combinations. Please refer to Motion
Analyzer software to verify compatibility. Download is available at http://www.ab.com/motion/software/analyzer.html.
Drive Family Linear Motor/Actuator Series Class Page Drive Family Linear Motor/Actuator Series Class Page
Kinetix 6000 Peak Enhancement Example 668 MP-Series Integrated Linear Stages 200V 718
MP-Series Integrated Linear Stages 200V 669 MP-Series Integrated Linear Stages 400V 720
MP-Series Integrated Linear Stages 400V 672 MP-Series Electric Cylinders 200V 722
Kinetix 300
Kinetix 6000 Servo Drives MP-Series Heavy Duty Electric and
and MP-Series Electric Cylinders 200V 676 Cylinders 400V 724
Kinetix 6200/ and
Kinetix 6500 MP-Series Heavy Duty Electric 400V 679 TL-Series Electric Cylinders 200V 728
Servo Drives Cylinders
LDC-Series Linear Motors 200V 683 MP-Series Integrated Linear Stages 731
LDC-Series Linear Motors 400V 687 Kinetix 3 TL-Series Electric Cylinders 733
200V
LDL-Series Linear Motors 200V 694 Servo Drives LDC-Series Linear Motors 736
MP-Series Integrated Linear Stages 698 LDL-Series Linear Motors 740
MP-Series Electric Cylinders 702 MP-Series Integrated Linear Stages 200V 744
MP-Series Heavy Duty Electric 704 MP-Series Integrated Linear Stages 400V 748
Kinetix 2000 Cylinders
200V
Servo Drives TL-Series Electric Cylinders 707 MP-Series Electric Cylinders 751
200V
Ultra3000 and
MP-Series Heavy Duty Electric
LDC-Series Linear Motors 710 Servo Drives 400V 754
Cylinders
LDL-Series Linear Motors 714 LDC-Series Linear Motors 200V 758
LDC-Series Linear Motors 400V 762
LDL-Series Linear Motors 200V 768
IMPORTANT You can configure Kinetix 6000 460V (series B) drives to operate with up to 250% peak current for limited duty cycles.
Drive/actuator performance specifications are given with and without the peak enhancement feature enabled. For more
information, refer to Kinetix 6000 Drive Performance Example with Peak Enhancement Feature on page 668.
IMPORTANT Before your Kinetix 6000 drive will deliver enhanced peak performance, you must enable the peak enhancement feature
by configuring your drive by using DriveExplorer or RSLogix 5000 software.
Refer to the Kinetix 6000 Multi-axis Servo Drive User Manual, publication 2094-UM001, to recalculate torque and
accel/decel limit values, and paste them into the appropriate Axis Properties dialog box in RSLogix 5000 software.
For sizing your drive/motor combination by using series-B drives and the peak enhancement feature, use Motion Analyzer
software, version 4.6 or later.
In this example, the MPAS-Bxxxx2-V20SxA linear stage, usually paired with the 2094-BM01 (series A) AM module, is
shown paired with the 2094-BMP5-S (series B) AM module. The two curves illustrate how the 2094-BMP5-S (series B)
drive, when configured for 250% peak, can achieve full performance.
System System
Maximum System Peak System Peak Linear Stage
Continuous Continuous Kinetix 6000
Linear Stage Speed Stall Current Stall Force Rated Output
Stall Current Stall Force 460V Drives
mm/s (in/s) Amps 0-pk N (lb) kW
Amps 0-pk N (lb)
5.90 865 (194) 2094-BMP5-S @ 150%
MPAS-Bxxxx2-V20SxA 1124 (44.3) 3.30 462 (104) 0.52 2094-BMP5-S @ 250%
6.60 968 (218)
2094-BM01-S @ 150%
400 89.9
400 89.9
200 45.0
200 45.0
0 0
0 0
0 200 400 600 800 1000 1200
0 200 400 600 800 1000 1200
Velocity (mm/s)
= Intermittent operating region Velocity (mm/s)
= Continuous operating region
= System operation for specified stroke length
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
MPAS-Axxxx2-V20SxA 1124 (44.3) (2) 4.54 462 (104) 9.10 968 (218) 0.62 2094-AMP5-S
5.2 103 (23.2) 10.5 231 (51.9) 2094-AMP5-S
MPAS-A6xxxB-ALMO2C 0.32
5.3 105 (23.6) 15.8 359 (80.7) 2094-AM01-S
10.5 222 (49.9) 2094-AMP5-S
MPAS-A6xxxB-ALMS2C 4.7 83.0 (18.7) 0.29
14.2 312 (70.1) 2094-AM01-S
17.0 417 (93.7) 2094-AM01-S
MPAS-A8xxxE-ALMO2C 7.0 189 (42.5) 0.53
18.5 456 (103) 2094-AM02-S
5000 (200)
5.2 127 (28.5) 10.5 240 (53.9) 2094-AMP5-S
MPAS-A8xxxE-ALMS2C 0.48
6.3 159 (35.7) 16.7 399 (89.7) 2094-AM01-S
17.0 630 (142) 2094-AM01-S
MPAS-A9xxxK-ALMO2C 6.7 285 (64.1) 0.77
18.3 680 (153) 2094-AM02-S
5.2 206 (46.3) 10.5 372 (83.6) 2094-AMP5-S
MPAS-A9xxxK-ALMS2C 0.69
6.1 245 (55.1) 16.5 601 (135) 2094-AM01-S
(1) For 900 mm stroke length, maximum speed is 176 mm/s (6.9 in/s). For 1020 mm stroke length, maximum speed is 143 mm/s (5.6 in/s).
(2) For 780 mm stroke length, maximum speed is 889 mm/s (35.0 in/s). For 900 mm stroke length, maximum speed is 715 mm/s (28.2 in/s). For 1020 mm stroke length,
maximum speed is 582 mm/s (22.9 in/s).
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
400 89.9
200 45.0
200 45.0
0 0 0 0
0 50 100 150 200 250 300 0 200 400 600 800 1000 1200
Velocity (mm/s) Velocity (mm/s)
50 11.2 50 11.2
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Velocity (mm/s) Velocity (mm/s)
1020 mm
200 45.0
780 mm
200 45.0
900 mm
< 660 mm
< 780 mm 0 0
0 0
0 50 100 150 200 250 300 0 200 400 600 800 1000 1200
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region
= System operation for specified stroke length
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives with MP-Series Linear Stages
This section provides system combination information for the Kinetix 6000 and Kinetix 6200/6500 (460V) drives when
matched with MP-Series (460V) integrated direct-drive or ballscrew linear stages. Included are power/brake and feedback
cable catalog numbers, system performance specifications, and the optimum force/velocity curves.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Linear Stage Performance Specifications with Kinetix 6200/Kinetix 6500 (460V) Drives
System System
Maximum System Peak System Peak Linear Stage Kinetix 6200/
Continuous Continuous
Linear Stage Speed Stall Current Stall Force Rated Output Kinetix 6500
Stall Current Stall Force
mm/s (in/s) Amps 0-pk N (lb) kW 460V Drives
Amps 0-pk N (lb)
MPAS-Bxxxx1-V05SxA 200 (7.9) (1) 1.75 521 (117) 3.50 1212 (272) 0.138 2094-BMP5-M
MPAS-Bxxxx2-V20SxA 1124 (44.3) (2) 3.30 462 (104) 6.60 968 (218) 0.52 2094-BMP5-M
MPAS-B8xxxF-ALMO2C 5000 (200) 3.50 189 (42.5) 9.30 456 (103) 0.527 2094-BMP5-M
MPAS-B8xxxF-ALMS2C 5000 (200) 3.15 159 (35.7) 8.37 399 (89.7) 0.475 2094-BMP5-M
MPAS-B9xxxL-ALMO2C 5000 (200) 3.40 285 (64.1) 9.10 680 (153) 0.768 2094-BMP5-M
MPAS-B9xxxL-ALMS2C 5000 (200) 3.03 245 (55.1) 8.19 601 (135) 0.69 2094-BMP5-M
(1) For 900 mm stroke length, maximum speed is 176 mm/s (6.9 in/s). For 1020 mm stroke length, maximum speed is 143 mm/s (5.6 in/s).
(2) For 780 mm stroke length, maximum speed is 889 mm/s (35.0 in/s). For 900 mm stroke length, maximum speed is 715 mm/s (28.2 in/s). For 1020 mm stroke length,
maximum speed is 582 mm/s (22.9 in/s).
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives/MP-Series Linear Stage Curves
2094-BMP5-S @ 150% or 2094-BMP5-M 2094-BMP5-S @ 250% or 2094-BMP5-M
and MPAS-B6xxx1-V05SxA and MPAS-B6xxx2-V20SxA
Force 1400 314.7 Force Force 1000 224.8 Force
(N) (lb) (N) (lb)
1200 269.8
800 179.8
1000 224.8
Intermittent curve represents
600 460V and 400V inputs 134.9
800 179.8
Intermittent curve represents
460V and 400V inputs
600 134.9 400 89.9
400 89.9
200 45.0
200 45.0
0 0 0 0
0 50 100 150 200 250 300 0 200 400 600 800 1000 1200
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region
= System operation with 400V AC (rms) input voltage
= System operation for specified stroke length
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives/MP-Series Linear Stage Curves, Continued
2094-BMP5-S @ 150% or 2094-BMP5-M 2094-BMP5-S @ 250% or 2094-BMP5-M
and MPAS-B8xxx1-V05SxA and MPAS-B8xxx2-V20SxA
Force 1400 314.7 Force Force 1000 224.8 Force
(N) (lb) (N) (lb)
1200 269.8
800 Intermittent curve 179.8
represents 460V and
1000 224.8 400V inputs
Intermittent curve
800 600 134.9
represents 460V and 179.8
400V inputs
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Velocity (mm/s) Velocity (mm/s)
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives/MP-Series Linear Stage Curves, Continued
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region
= System operation with 400V AC (rms) input voltage
= System operation for specified stroke length
Kinetix 6000 and Kinetix 6200/6500 Drives with MP-Series Electric Cylinders
This section provides system combination information for the Kinetix 6000 and Kinetix 6200/6500 drives when matched
with MP-Series electric cylinders. Included are power/brake and feedback cable catalog numbers, system performance
specifications, and the optimum force/velocity curves.
2090-CFBM7DF-CEAAxx
2090-CFBM7DD-CEAAxx (standard)
MPAR-A/B3xxxE 2090-CPxM7DF-16AAxx (standard) 2090-CFBM7DF-CEAFxx
MPAR-A/B3xxxH 2090-CPxM7DF-16AFxx (continuous-flex) 2090-CFBM7DD-CEAFxx (continuous-flex)
Absolute High-resolution Feedback
(1) Use low-profile connector kit (catalog number 2090-K6CK-D15M) or panel-mounted breakout components on drive end. Refer to Breakout Components and Connector Kits
on page 442.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Electric Cylinder Performance Specifications with Kinetix 6000 and Kinetix 6200/6500 Drives
Performance Specifications with Kinetix 6200/6500 (460V) Drives
System System
Maximum System Peak System Peak Kinetix 6200/
Electric Continuous Continuous Rated Output
Speed Stall Current Stall Force Kinetix 6500
Cylinder Stall Current Stall Force kW
mm/s (in/s) Amps 0-pk N (lb) 460V Drives
Amps 0-pk N (lb)
MPAR-B1xxxB 150 1.15 240 (53.9) 1.35 300 (67.4) 0.036 2094-BMP5-M
MPAR-B1xxxE 500 1.49 280 (62.9) 1.71 350 (78.7) 0.140 2094-BMP5-M
MPAR-B2xxxC 250 1.67 420 (94.4) 1.90 525 (118) 0.105 2094-BMP5-M
MPAR-B2xxxF 640 3.29 640 (144) 3.93 800 (180) 0.410 2094-BMP5-M
MPAR-B3xxxE 500 5.16 2000 (450) 6.17 2500 (562) 1.00 2094-BM01-M
MPAR-B3xxxH 1000 6.13 1300 (292) 6.79 1625 (365) 1.30 2094-BM01-M
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
System System
Maximum System Peak System Peak
Electric Continuous Continuous Rated Output Kinetix 6000
Speed Stall Current Stall Force
Cylinder Stall Current Stall Force kW 230V Drives
mm/s (in/s) Amps 0-pk N (lb)
Amps 0-pk N (lb)
MPAR-A1xxxB 150 1.15 240 (53.9) 1.35 300 (67.4) 0.036 2094-AMP5-S
MPAR-A1xxxE 500 2.16 280 (62.9) 2.48 350 (78.7) 0.140 2094-AMP5-S
MPAR-A2xxxC 250 2.42 420 (94.4) 2.72 525 (118) 0.105 2094-AMP5-S
MPAR-A2xxxF 640 4.54 640 (144) 5.41 800 (180) 0.410 2094-AM01-S
MPAR-A3xxxE 500 10.33 2000 (450) 12.34 2500 (562) 1.00 2094-AM02-S
MPAR-A3xxxH 1000 12.20 1300 (292) 16.40 1625 (365) 1.30 2094-AM02-S
System System
Maximum System Peak System Peak
Electric Continuous Continuous Rated Output Kinetix 6000
Speed Stall Current Stall Force
Cylinder Stall Current Stall Force kW 460V Drives
mm/s (in/s) Amps 0-pk N (lb)
Amps 0-pk N (lb)
MPAR-B1xxxB 150 1.15 240 (53.9) 1.35 300 (67.4) 0.036 2094-BMP5-S @ 150%
MPAR-B1xxxE 500 1.49 280 (62.9) 1.71 350 (78.7) 0.140 2094-BMP5-S @ 150%
MPAR-B2xxxC 250 1.67 420 (94.4) 1.90 525 (118) 0.105 2094-BMP5-S @ 150%
MPAR-B2xxxF 640 3.29 640 (144) 3.93 800 (180) 0.410 2094-BMP5-S @ 150%
4.0 1532 (344) 2094-BMP5-S @ 250%
MPAR-B3xxxE 500 6.17 2500 (562) 1.00
5.16 2000 (450) 2094-BM01-S @ 150%
4.0 841 (189) 2094-BMP5-S @ 250%
MPAR-B3xxxH 1000 6.79 1625 (365) 1.30
6.13 1300 (292) 2094-BM01-S @ 150%
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
0 0 0 0
0 50 100 150 200 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
200 45.0
200 45.0
100 22.5
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600 700 800
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 100 200 300 400 500 600 0 200 400 600 800 1000 1200
Velocity (mm/s) = Intermittent operating region Velocity (mm/s)
= Continuous operating region
Kinetix 6000 and Kinetix 6200/6500 Drives/MP-Series Heavy Duty Electric Cylinders
This section provides system combination information for the Kinetix 6000 and the Kinetix 6200/6500 drives when
matched with MP-Series heavy-duty electric cylinders. Included are power/brake and feedback cable catalog numbers,
system performance specifications, and the optimum force/velocity curves.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Kinetix 6000 and Kinetix 6200/6500 Drives/MP-Series (ball screw) Electric Cylinder Curves
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
5000 1124
6000 1349
4000 899
4000 899 3000 674
2000 450
2000 450
1000 225
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region @ 25 °C (77 °F)
= Continuous operating region @ 40 °C (104 °F)
Kinetix 6000 and Kinetix 6200/6500 Drives/MP-Series (roller screw) Electric Cylinder Curves
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region @ 25 °C (77 °F)
= Continuous operating region @ 40 °C (104 °F)
74…111
LDC-C030100-DHT 4.1…6.1 12.1 188 (42) 0.37…0.55 2094-AM01-S
(17…25)
LDC-C030200-DHT 10.0 (32.8) 8.1…12.2 148…222 24.3 2094-AM02-S
375 (84) 0.74…1.11
LDC-C030200-EHT 4.1…6.1 (33…50) 12.1 2094-AM01-S
119…179
LDC-C050100-DHT 3.9…5.9 11.7 302 (68) 0.59…0.89 2094-AM01-S
(27…40)
LDC-C050200-DHT 7.9…11.8 240…359 23.3 2094-AM02-S
10.0 (32.8) 600 (135) 1.20…1.79
LDC-C050200-EHT 3.9…5.9 (54…81) 11.6 2094-AMP5-S
LDC-C050300-DHT 11.8…17.7 363…544 35.9 2094-AM03-S
941 (212) 1.81…2.72
LDC-C050300-EHT 3.9…5.9 (82…122) 12.0 2094-AMP5-S
(1) Values represent the range between no cooling (low value) and water cooling (high value).
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
40 9.0 80 18.0
0 0 0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDC-Cxxxxxx-DHT)
= Intermittent operating region (LDC-Cxxxxxx-EHT)
= Continuous operating region
0 0 0 0
0 2 4 6 8 0 2 4 6 8
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDC-Cxxxxxx-DHT)
= Intermittent operating region (LDC-Cxxxxxx-EHT)
= Continuous operating region
0 0 0 0
0 1 2 3 4 0 1 2 3 4
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 0 0.5 1 1.5 2 2.5 3
Velocity (m/s) Velocity (m/s)
4000 899
3000 674
Water Cooling
Air Cooling
2000 450
No Cooling
1000 225
0 0
0 0.5 1 1.5 2 2.5 3
Velocity (m/s)
= Intermittent operating region (LDC-Cxxxxxx-DHT)
= Intermittent operating region (LDC-Cxxxxxx-EHT)
= Continuous operating region
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives with LDC-Series Linear Motors
This section provides system combination information for the Kinetix 6000 and Kinetix 6200/6500 (460V) drives when
matched with LDC-Series iron-core linear motors. Included are power and feedback cable catalog numbers, system
performance specifications, and the optimum force/velocity curves.
IMPORTANT When using Kinetix 6000 (series B) drives, configured for enhanced peak performance, you can usually achieve full motor
performance with a smaller drive. Kinetix 6200 and Kinetix 6500 drives are configured for enhanced peak performance by
default. Expect the same peak performance from Kinetix 6200 and Kinetix 6500 drives as Kinetix 6000 (series B) drives
configured for enhanced peak performance.
Refer to Kinetix 6000 IAM/AM Module Series Change on page 276 for more Kinetix 6000 enhanced-peak information.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 5.000 or later.
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 5.000 or later.
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives/LDC-Series Linear Motor Curves
40 9.0 80 18.0
0 0 0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 2 4 6 8 10 12 0 2 4 6 8
Velocity (m/s) Velocity (m/s)
= Intermittent operating region
= Intermittent operating region with 400V AC (rms) input voltage
= Continuous operating region
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives/LDC-Series Linear Motor Curves, Continued
2094-BM02-S @ 250% or 2094-BM02-M 2094-BM01-S @ 150% or 2094-BM01-M
and LDC-C050300-DHT and LDC-C050300-EHT
Force 1000 225 225
Force Force 1000 Force
(N) (lb) (N) (lb)
800 180 800 180
0 0 0 0
0 2 4 6 8 10 12 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 2 4 6 8 10 12 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 2 4 6 8 10 12 0 1 2 3 4
Velocity (m/s) Velocity (m/s)
= Intermittent operating region
= Intermittent operating region with 400V AC (rms) input voltage
= Continuous operating region
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives/LDC-Series Linear Motor Curves, Continued
2094-BM03-S @ 250% or 2094-BM03-M 2094-BM02-S @ 250% or 2094-BM02-M
and LDC-C075400-DHT and LDC-C075400-EHT
Force 2000 450 Force Force 2000 450 Force
(N) (lb) (N) (lb)
1600 360 1600 360
0 0 0 0
0 2 4 6 8 10 12 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 2 4 6 8 0 0.5 1 1.5 2 2.5 3
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 2 4 6 8 0 1 2 3 4
Velocity (m/s) Velocity (m/s)
= Intermittent operating region
= Intermittent operating region with 400V AC (rms) input voltage
= Continuous operating region
Kinetix 6000 and Kinetix 6200/6500 (460V) Drives/LDC-Series Linear Motor Curves, Continued
2094-BM03-S @ 250% or 2094-BM03-M 2094-BM02-S @ 250% or 2094-BM02-M
and LDC-C100600-DHT and LDC-C100600-EHT
4000 899 4000 899
Force Force Force Force
(N) 3500 787 (lb) (N) 3500 787 (lb)
0 0 0 0
0 2 4 6 8 0 1 2 3 4
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 5 6 0 0.5 1 1.5 2 2.5 3
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 5 6 0 0.5 1 1.5 2 2.5 3
Velocity (m/s) Velocity (m/s)
= Intermittent operating region
= Intermittent operating region with 400V AC (rms) input voltage
= Continuous operating region
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
0 0 0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDL-xxxxxxx-DHT)
= Intermittent operating region (LDL-xxxxxxx-EHT)
= Continuous operating region
0 0 0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8
Velocity (m/s) Velocity (m/s)
600 135
400 89.9
400 90.0
200 45.0
200 45.0
0 0 0 0
0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDL-xxxxxxx-DHT)
= Intermittent operating region (LDL-xxxxxxx-EHT)
= Continuous operating region
0 0 0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
1000 225
800 180
750 169
500 112
400 90.0
250 56.0
0 0 0 0
0 1 2 3 4 5 6 0 1 2 3 4
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDL-xxxxxxx-DHT)
= Intermittent operating region (LDL-xxxxxxx-EHT)
= Continuous operating region
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
400 89.9
200 45.0
200 45.0
0 0 0 0
0 50 100 150 200 250 300 0 200 400 600 800 1000 1200
Velocity (mm/s) Velocity (mm/s)
50 11.2 50 11.2
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Velocity (mm/s) Velocity (mm/s)
1020 mm
200 45.0
780 mm
200 45.0
900 mm
< 660 mm
< 780 mm 0 0
0 0
0 50 100 150 200 250 300 0 200 400 600 800 1000 1200
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region
= System operation (single-phase input)
= System operation for specified stroke length
2090-CFBM7DF-CEAAxx or
2090-CFBM7DD-CEAAxx (standard)
MPAR-A3xxxE 2090-CPxM7DF-16AAxx (standard) 2090-CFBM7DF-CEAFxx
MPAR-A3xxxH 2090-CPxM7DF-16AFxx (continuous-flex) 2090-CFBM7DD-CEAFxx (continuous-flex)
Absolute High-resolution Feedback
(1) Use low-profile connector kit (catalog number 2090-K2CK-D15M) or panel-mounted breakout components on drive end. Refer to Breakout Components and Connector Kits
on page 442.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
0 0 0 0
0 50 100 150 200 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
200 45.0
200 45.0
100 22.5
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600 700 800
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 100 200 300 400 500 600 0 200 400 600 800 1000 1200
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region
Kinetix 2000 (230V) Drives with MP-Series Heavy Duty Electric Cylinders
This section provides system combination information for the Kinetix 2000 drives when matched with MP-Series (230V)
heavy-duty electric cylinders. Included are power/brake and feedback cable catalog numbers, system performance
specifications, and the optimum force/velocity curves.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Kinetix 2000 Drives/MP-Series Heavy Duty (ball screw) Electric Cylinder Curves
2093-AM01 and MPAI-A3xxxC 2093-AM01 and MPAI-A3xxxE
Force 5000 1124 Force
Force 5000 1124 Force
(N) (lb) (N) (lb)
4000 899 4000 899
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
5000 1124
6000 1349
4000 899
4000 899 3000 674
2000 450
2000 450
1000 225
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region @ 25 °C (77 °F)
= Continuous operating region @ 40 °C (104 °F)
Kinetix 2000 Drives/MP-Series Heavy Duty (roller screw) Electric Cylinder Curves
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region @ 25 °C (77 °F)
= Continuous operating region @ 40 °C (104 °F)
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
0 0 0 0
0 50 100 150 200 0 50 100 150 200
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 100 200 300 400 500 600 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region
0 0 0 0
0 100 200 300 400 500 600 700 800 0 100 200 300 400 500 600 700 800
Velocity (mm/s) Velocity (mm/s)
1200 Intermittent curve represents 270 1200 Intermittent curve represents 270
3-phase and 1-phase inputs 3-phase and 1-phase inputs
0 0 0 0
0 100 200 300 400 500 600 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
0 0 0
0
1000 1200 0 200 400 600 800 1000 1200
0 200 400 600 800
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region
74…111
LDC-C030100-DHT 4.1…6.1 12.1 188 (42) 0.37…0.55 2093-AMP5
(17…25)
LDC-C030200-DHT 10.0 (32.8) 8.1…12.2 148…222 24.3 2093-AM01
375 (84) 0.74…1.11
LDC-C030200-EHT 4.1…6.1 (33…50) 12.1 2093-AMP5
119…179
LDC-C050100-DHT 3.9…5.9 11.7 302 (68) 0.59…0.89 2093-AMP5
(27…40)
LDC-C050200-DHT 7.9…11.8 240…359 23.3 2093-AM01
10.0 (32.8) 600 (135) 1.20…1.79
LDC-C050200-EHT 3.9…5.9 (54…81) 11.6 2093-AMP5
LDC-C050300-DHT 11.8…17.7 363…544 35.9 2093-AM02
941 (212) 1.81…2.72
LDC-C050300-EHT 3.9…5.9 (82…122) 12.0 2093-AMP5
(1) Values represent the range between no cooling (low value) and water cooling (high value).
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
40 9.0 80 18.0
0 0 0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDC-Cxxxxxx-DHT)
= Intermittent operating region (LDC-Cxxxxxx-EHT)
= Continuous operating region
0 0 0 0
0 2 4 6 8 0 2 4 6 8
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDC-Cxxxxxx-DHT)
= Intermittent operating region (LDC-Cxxxxxx-EHT)
= Continuous operating region
0 0 0 0
0 1 2 3 4 0 1 2 3 4
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 0 0.5 1 1.5 2 2.5 3
Velocity (m/s) Velocity (m/s)
4000 899
3000 674
Water Cooling
Air Cooling
2000 450
No Cooling
1000 225
0 0
0 0.5 1 1.5 2 2.5 3
Velocity (m/s)
= Intermittent operating region (LDC-Cxxxxxx-DHT)
= Intermittent operating region (LDC-Cxxxxxx-EHT)
= Continuous operating region
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
0 0 0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDL-xxxxxxx-DHT)
= Intermittent operating region (LDL-xxxxxxx-EHT)
= Continuous operating region
0 0 0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8
Velocity (m/s) Velocity (m/s)
600 135
400 89.9
400 90.0
200 45.0
200 45.0
0 0 0 0
0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDL-xxxxxxx-DHT)
= Intermittent operating region (LDL-xxxxxxx-EHT)
= Continuous operating region
0 0 0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
1000 225
800 180
750 169
500 112
400 90.0
250 56.0
0 0 0 0
0 1 2 3 4 5 6 0 1 2 3 4
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDL-xxxxxxx-DHT)
= Intermittent operating region (LDL-xxxxxxx-EHT)
= Continuous operating region
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
MPAS-Axxxx2-V20SxA 1124 (44.3) (2) 4.54 462 (104) 9.10 968 (218) 0.62 2097-V33PR3
(1) For 900 mm stroke length, maximum speed is 176 mm/s (6.9 in/s). For 1020 mm stroke length, maximum speed is 143 mm/s (5.6 in/s).
(2) For 780 mm stroke length, maximum speed is 889 mm/s (35.0 in/s). For 900 mm stroke length, maximum speed is 715 mm/s (28.2 in/s). For 1020 mm stroke length,
maximum speed is 582 mm/s (22.9 in/s).
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
400 89.9
200 45.0
200 45.0
0 0 0 0
0 50 100 150 200 250 300 0 200 400 600 800 1000 1200
Velocity (mm/s) Velocity (mm/s)
1020 mm
200 45.0
780 mm
200 45.0
900 mm
< 660 mm
< 780 mm 0 0
0 0
0 50 100 150 200 250 300 0 200 400 600 800 1000 1200
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region
= System operation for specified stroke length
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
MPAS-Bxxxx1-V05SxA 200 (7.9) (1) 1.75 521 (117) 3.50 1212 (272) 0.138 2097-V34PR3
MPAS-Bxxxx2-V20SxA 1124 (44.3) (2) 3.30 462 (104) 6.60 968 (218) 0.52 2097-V34PR5
(1) For 900 mm stroke length, maximum speed is 176 mm/s (6.9 in/s). For 1020 mm stroke length, maximum speed is 143 mm/s (5.6 in/s).
(2) For 780 mm stroke length, maximum speed is 889 mm/s (35.0 in/s). For 900 mm stroke length, maximum speed is 715 mm/s (28.2 in/s). For 1020 mm stroke length,
maximum speed is 582 mm/s (22.9 in/s).
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
0 0 0 0
0 50 100 150 200 250 300 0 200 400 600 800 1000 1200
Velocity (mm/s) Velocity (mm/s)
600 134.9
400 89.9
1020 mm
400 89.9 900 mm
1020 mm 200 45.0
200 45.0 780 mm
900 mm
< 780 mm < 660 mm
0 0 0 0
0 50 100 150 200 250 300 0 200 400 600 800 1000 1200
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region
= System operation for specified stroke length
2090-CFBM7DF-CEAAxx or
2090-CFBM7DD-CEAAxx (standard)
MPAR-A/B3xxxE 2090-CPxM7DF-16AAxx (standard) 2090-CFBM7DF-CEAFxx
MPAR-A/B3xxxH 2090-CPxM7DF-16AFxx (continuous-flex) 2090-CFBM7DD-CEAFxx (continuous-flex)
Absolute High-resolution Feedback
(1) Use low-profile connector kit (2090-K2CK-D15M) or panel-mounted breakout components on drive end. Refer to Breakout Components and Connector Kits on page 442.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
System System
Maximum System Peak System Peak
Electric Continuous Continuous Rated Output Kinetix 300
Speed Stall Current Stall Force
Cylinder Stall Current Stall Force kW Drives
mm/s (in/s) Amps 0-pk N (lb)
Amps 0-pk N (lb)
MPAR-A1xxxB 150 1.15 240 (53.9) 1.35 300 (67.4) 0.036
MPAR-A1xxxE 500 2.16 280 (62.9) 2.48 350 (78.7) 0.140
2097-V33PR1
MPAR-A2xxxC 250 2.42 420 (94.4) 2.72 525 (118) 0.105
MPAR-A2xxxF 640 4.54 640 (144) 5.41 800 (180) 0.410
MPAR-A3xxxE 500 10.33 2000 (450) 12.34 2500 (562) 1.00
2097-V33PR5
MPAR-A3xxxH 1000 12.20 1300 (292) 16.40 1625 (365) 1.30
0 0 0 0
0 50 100 150 200 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
200 45.0
200 45.0
100 22.5
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600 700 800
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 100 200 300 400 500 600 0 200 400 600 800 1000 1200
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Kinetix 300 Drives/MP-Series Heavy Duty (ball screw) Electric Cylinder Curves
2097-V33PR3 and MPAI-A3xxxC 2097-V33PR3 and MPAI-A3xxxE
2097-V34PR3 and MPAI-B3xxxC 2097-V34PR3 and MPAI-B3xxxE
Force 5000 1124 Force Force 5000 1124 Force
(N) (lb) (N) (lb)
4000 899 4000 899
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
4000 899
4000 899 3000 674
2000 450
2000 450
1000 225
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region @ 25 °C (77 °F)
= Continuous operating region @ 40 °C (104 °F)
Kinetix 300 Drives/MP-Series Heavy Duty (roller screw) Electric Cylinder Curves
2097-V33PR5 and MPAI-A3xxxR 2097-V33PR3 and MPAI-A3xxxS
2097-V34PR5 and MPAI-B3xxxR 2097-V34PR3 and MPAI-B3xxxS
Force 8000 1798 Force Force 4000 899 Force
(N) (lb) (N) (lb)
7000 1573 3500 787
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region @ 25 °C (77 °F)
= Continuous operating region @ 40 °C (104 °F)
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
0 0 0 0
0 50 100 150 200 0 50 100 150 200
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 100 200 300 400 500 600 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region
0 0 0 0
0 100 200 300 400 500 600 700 800 0 100 200 300 400 500 600 700 800
Velocity (mm/s) Velocity (mm/s)
1200 Intermittent curve represents 270 1200 Intermittent curve represents 270
3-phase and 1-phase inputs 3-phase and 1-phase inputs
0 0 0 0
0 100 200 300 400 500 600 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
0 0 0
0
1000 1200 0 200 400 600 800 1000 1200
0 200 400 600 800
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
50 11.2 50 11.2
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region
= System operation for specified stroke length
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
0 0 0 0
0 50 100 150 200 0 50 100 150 200
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 100 200 300 400 500 600 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region
0 0 0 0
0 100 200 300 400 500 600 700 800 0 100 200 300 400 500 600 700 800
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 100 200 300 400 500 600 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
0 0 0
0
1000 1200 0 200 400 600 800 1000 1200
0 200 400 600 800
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region
74…111
LDC-C030100-DHT 4.1…6.1 12.1 188 (42) 0.37…0.55 2071-AP4
(17…25)
LDC-C030200-DHT 10.0 (32.8) 8.1…12.2 148…222 24.3 2071-A10
375 (84) 0.74…1.11
LDC-C030200-EHT 4.1…6.1 (33…50) 12.1 2071-AP4
119…179
LDC-C050100-DHT 3.9…5.9 11.7 302 (68) 0.59…0.89 2071-AP4
(27…40)
LDC-C050200-DHT 7.9…11.8 240…359 23.3 2071-A10
10.0 (32.8) 600 (135) 1.20…1.79
LDC-C050200-EHT 3.9…5.9 (54…81) 11.6 2071-AP4
LDC-C050300-DHT 11.8…17.7 363…544 35.9 2071-A15
941 (212) 1.81…2.72
LDC-C050300-EHT 3.9…5.9 (82…122) 12.0 2071-AP4
(1) Values represent the range between no cooling (low value) and water cooling (high value).
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 5.000 or later.
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 5.000 or later.
40 9.0 80 18.0
0 0 0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDC-Cxxxxxx-DHT)
= Intermittent operating region (LDC-Cxxxxxx-EHT)
= Continuous operating region
0 0 0 0
0 2 4 6 8 0 2 4 6 8
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDC-Cxxxxxx-DHT)
= Intermittent operating region (LDC-Cxxxxxx-EHT)
= Continuous operating region
0 0 0 0
0 1 2 3 4 0 1 2 3 4
Velocity (m/s) Velocity (m/s)
4000 899
3000 674
Water Cooling
Air Cooling
2000 450
No Cooling
1000 225
0 0
0 0.5 1 1.5 2 2.5 3
Velocity (m/s)
= Intermittent operating region (LDC-Cxxxxxx-DHT)
= Intermittent operating region (LDC-Cxxxxxx-EHT)
= Continuous operating region
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
0 0 0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDL-xxxxxxx-DHT)
= Intermittent operating region (LDL-xxxxxxx-EHT)
= Continuous operating region
0 0 0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8
Velocity (m/s) Velocity (m/s)
600 135
400 89.9
400 90.0
200 45.0
200 45.0
0 0 0 0
0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDL-xxxxxxx-DHT)
= Intermittent operating region (LDL-xxxxxxx-EHT)
= Continuous operating region
0 0 0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
400 90.0
300 67.4
200 45.0
0 0 0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
1000 225
800 180
750 169
500 112
400 90.0
250 56.0
0 0 0 0
0 1 2 3 4 5 6 0 1 2 3 4
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDL-xxxxxxx-DHT)
= Intermittent operating region (LDL-xxxxxxx-EHT)
= Continuous operating region
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
400 89.9
200 45.0
200 45.0
0 0 0 0
0 50 100 150 200 250 300 0 200 400 600 800 1000 1200
Velocity (mm/s) Velocity (mm/s)
50 11.2 50 11.2
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region
= System operation for specified stroke length
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
MPAS-Bxxxx2-V20SxA 1124 (44.3) (2) 3.30 462 (104) 6.60 968 (218) 0.52 2098-DSD-HV030
MPAS-B8xxxF-ALMO2C 5000 (200) 3.50 189 (42.5) 9.30 456 (103) 0.527 2098-DSD-HV030
MPAS-B8xxxF-ALMS2C 5000 (200) 3.15 159 (35.7) 8.37 399 (89.7) 0.475 2098-DSD-HV030
MPAS-B9xxxL-ALMO2C 5000 (200) 3.40 285 (64.1) 9.10 680 (153) 0.768 2098-DSD-HV030
MPAS-B9xxxL-ALMS2C 5000 (200) 3.03 245 (55.1) 8.19 601 (135) 0.69 2098-DSD-HV030
(1) For 900 mm stroke length, maximum speed is 176 mm/s (6.9 in/s). For 1020 mm stroke length, maximum speed is 143 mm/s (5.6 in/s).
(2) For 780 mm stroke length, maximum speed is 889 mm/s (35.0 in/s). For 900 mm stroke length, maximum speed is 715 mm/s (28.2 in/s). For 1020 mm stroke length,
maximum speed is 582 mm/s (22.9 in/s).
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
0 0 0 0
0 50 100 150 200 250 300 0 200 400 600 800 1000 1200
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Velocity (mm/s) = Intermittent operating region Velocity (mm/s)
= Continuous operating region
= System operation with 400V AC (rms) input voltage
= System operation for specified stroke length
0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region
= System operation with 400V AC (rms) input voltage
= System operation for specified stroke length
2090-CFBM7DF-CEAAxx
2090-CFBM7DD-CEAAxx (standard)
MPAR-A/B3xxxE 2090-CPxM7DF-16AAxx (standard) 2090-CFBM7DF-CEAFxx
MPAR-A/B3xxxH 2090-CPxM7DF-16AFxx (continuous-flex) 2090-CFBM7DD-CEAFxx (continuous-flex)
Absolute High-resolution Feedback
(1) Use drive-mounted breakout board (catalog number 2090-UXBB-DM15) or panel-mounted breakout components on drive end. Refer to Breakout Components and Connector
Kits on page 442.
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
System System
Maximum System Peak System Peak
Electric Continuous Continuous Rated Output Ultra3000
Speed Stall Current Stall Force
Cylinder Stall Current Stall Force kW 230V Drives
mm/s (in/s) Amps 0-pk N (lb)
Amps 0-pk N (lb)
MPAR-A1xxxB 150 1.15 240 (53.9) 1.35 300 (67.4) 0.036
2098-DSD-005
MPAR-A1xxxE 500 2.16 280 (62.9) 2.48 350 (78.7) 0.140
MPAR-A2xxxC 250 2.42 420 (94.4) 2.72 525 (118) 0.105
2098-DSD-010
MPAR-A2xxxF 640 4.54 640 (144) 5.41 800 (180) 0.410
MPAR-A3xxxE 500 10.33 2000 (450) 12.34 2500 (562) 1.00 2098-DSD-030 (1)
MPAR-A3xxxH 1000 12.20 1300 (292) 16.40 1625 (365) 1.30 2098-DSD-030
(1) Use of catalog number 2098-DSD020x-xx is acceptable for applications with actuators and continuous force derated by 5%.
System System
Maximum System Peak System Peak
Electric Continuous Continuous Rated Output Ultra3000
Speed Stall Current Stall Force
Cylinder Stall Current Stall Force kW 460V Drives
mm/s (in/s) Amps 0-pk N (lb)
Amps 0-pk N (lb)
MPAR-B1xxxB 150 1.15 240 (53.9) 1.35 300 (67.4) 0.036
MPAR-B1xxxE 500 1.49 280 (62.9) 1.71 350 (78.7) 0.140
MPAR-B2xxxC 250 1.67 420 (94.4) 1.90 525 (118) 0.105
2098-DSD-HV030
MPAR-B2xxxF 640 3.29 640 (144) 3.93 800 (180) 0.410
MPAR-B3xxxE 500 5.16 2000 (450) 6.17 2500 (562) 1.00
MPAR-B3xxxH 1000 6.13 1300 (292) 6.79 1625 (365) 1.30
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
0 0 0 0
0 50 100 150 200 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
200 45.0
200 45.0
100 22.5
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600 700 800
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 100 200 300 400 500 600 0 200 400 600 800 1000 1200
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
2000 450
2000 450
1000 225
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region @ 25 °C (77 °F)
= Continuous operating region @ 40 °C (104 °F)
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
0 0 0 0
0 50 100 150 200 250 300 0 100 200 300 400 500 600
Velocity (mm/s) Velocity (mm/s)
= Intermittent operating region
= Continuous operating region @ 25 °C (77 °F)
= Continuous operating region @ 40 °C (104 °F)
74…111
LDC-C030100-DHT 4.1…6.1 12.1 188 (42) 0.37…0.55 2098-DSD-010
(17…25)
10.0 (32.8)
LDC-C030200-DHT 8.1…12.2 148…222 24.3 2098-DSD-020
375 (84) 0.74…1.11
LDC-C030200-EHT 4.1…6.1 (33…50) 12.1 2098-DSD-010
119…179
LDC-C050100-DHT 3.9…5.9 11.7 302 (68) 0.59…0.89 2098-DSD-010
(27…40)
LDC-C050200-DHT 7.9…11.8 240…359 23.3 2098-DSD-020
10.0 (32.8) 600 (135) 1.20…1.79
LDC-C050200-EHT 3.9…5.9 (54…81) 11.6 2098-DSD-010
LDC-C050300-DHT 11.8…17.7 363…544 35.9 2098-DSD-075
941 (212) 1.81…2.72
LDC-C050300-EHT 3.9…5.9 (82…122) 12.0 2098-DSD-010
(1) Values represent the range between no cooling (low value) and water cooling (high value).
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
40 9.0 80 18.0
0 0 0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDC-Cxxxxxx-DHT)
= Intermittent operating region (LDC-Cxxxxxx-EHT)
= Continuous operating region
0 0 0 0
0 2 4 6 8 0 2 4 6 8
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDC-Cxxxxxx-DHT)
= Intermittent operating region (LDC-Cxxxxxx-EHT)
= Continuous operating region
0 0 0 0
0 1 2 3 4 0 1 2 3 4
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 0 0.5 1 1.5 2 2.5 3
Velocity (m/s) Velocity (m/s)
4000 899
3000 674
Water Cooling
Air Cooling
2000 450
No Cooling
1000 225
0 0
0 0.5 1 1.5 2 2.5 3
Velocity (m/s)
= Intermittent operating region (LDC-Cxxxxxx-DHT)
= Intermittent operating region (LDC-Cxxxxxx-EHT)
= Continuous operating region
74…111
LDC-C030100-DHT 4.1…6.1 12.1 188 (42) 0.37…0.55 2098-DSD-HV030
(17…25)
10.0 (32.8)
LDC-C030200-DHT 8.1…12.2 148…222 24.3 2098-DSD-HV100
375 (84) 0.74…1.11
LDC-C030200-EHT 4.1…6.1 (33…50) 12.1 2098-DSD-HV030
119…179
LDC-C050100-DHT 3.9…5.9 11.7 302 (68) 0.59…0.89 2098-DSD-HV030
(27…40)
LDC-C050200-DHT 7.9…11.8 240…359 23.3 2098-DSD-HV100
10.0 (32.8) 600 (135) 1.20…1.79
LDC-C050200-EHT 3.9…5.9 (54…81) 11.6 2098-DSD-HV030
LDC-C050300-DHT 11.8…17.7 363…544 35.9 2098-DSD-HV100
941 (212) 1.81…2.72
LDC-C050300-EHT 3.9…5.9 (82…122) 12.0 2098-DSD-HV030
(1) Values represent the range between no cooling (low value) and water cooling (high value).
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated
line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
40 9.0 80 18.0
0 0 0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Velocity (m/s) Velocity (m/s)
240 53.9
240 53.9
Water Cooling
Air Cooling
160 36.0
160 Water Cooling 36.0
No Cooling
Air Cooling
80 18.0 No Cooling
80 18.0
0 0
0 0
0 2 4 6 8 10 12
0 2 4 6 8 10 12
Velocity (m/s)
Velocity (m/s)
0 0 0 0
0 2 4 6 8 10 12 0 2 4 6 8
Velocity (m/s) Velocity (m/s)
= Intermittent operating region
= Intermittent operating region with 400V AC (rms) input voltage
= Continuous operating region
0 0 0 0
0 2 4 6 8 10 12 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 2 4 6 8 10 12 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 2 4 6 8 10 12 0 1 2 3 4
Velocity (m/s) Velocity (m/s)
= Intermittent operating region
= Intermittent operating region with 400V AC (rms) input voltage
= Continuous operating region
0 0 0 0
0 2 4 6 8 10 12 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 2 4 6 8 0 0.5 1 1.5 2 2.5 3
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 2 4 6 8 0 1 2 3 4
Velocity (m/s) Velocity (m/s)
= Intermittent operating region
= Intermittent operating region with 400V AC (rms) input voltage
= Continuous operating region
0 0 0 0
0 2 4 6 8 0 1 2 3 4
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 5 6 0 0.5 1 1.5 2 2.5 3
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 5 6 0 0.5 1 1.5 2 2.5 3
Velocity (m/s) Velocity (m/s)
= Intermittent operating region
= Intermittent operating region with 400V AC (rms) input voltage
= Continuous operating region
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on page 397.
Cable length xx is in meters. Refer to 2090-Series Motor/Actuator Cable Specifications beginning on page 411.
Motor-end connector kits are available for motor power/brake and feedback cables. Refer to 2090-Series Motor-end Cable Connector Kits on page 424 for catalog numbers.
0 0 0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDL-xxxxxxx-DHT)
= Intermittent operating region (LDL-xxxxxxx-EHT)
= Continuous operating region
150 33.7
300 67.4
100 22.5
200 45.0
50 11.2
100 22.4
0 0
0 2 4 6 8 10 12 0 0
Velocity (m/s) 0 2 4 6 8 10 12
0 0 0 0
0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8
Velocity (m/s) Velocity (m/s)
600 135
400 89.9
400 90.0
200 45.0
200 45.0
0 0 0 0
0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDL-xxxxxxx-DHT)
= Intermittent operating region (LDL-xxxxxxx-EHT)
= Continuous operating region
0 0 0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Velocity (m/s) Velocity (m/s)
0 0 0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Velocity (m/s) Velocity (m/s)
1000 225
800 180
750 169
500 112
400 90.0
250 56.0
0 0 0 0
0 1 2 3 4 5 6 0 1 2 3 4
Velocity (m/s) Velocity (m/s)
= Intermittent operating region (LDL-xxxxxxx-DHT)
= Intermittent operating region (LDL-xxxxxxx-EHT)
= Continuous operating region
Notes:
IAM 286 E
mounting bracket 469 electric cylinders
power rail 458
Bulletin MPAI 183
shunt module 463
Bulletin MPAR 134
slot filler 464
Bulletin TLAR 134
Kinetix 6200/6500
enclosure sizing
AM 264
IAM 261 Kinetix 2000 318
Kinetix 7000 334 Kinetix 3 357
LDC-Series linear motors 213 Kinetix 300 347
cooling plate 219 Kinetix 6000 298
magnet track 218 Kinetix 6200/6500 270
LDL-Series linear motors 231 Kinetix 7000 331
magnet channel 234 Ultra3000 368
motor coil 232 Ultra5000 385
LIM 480 encoders 471
motor brake cable 424 environmental ratings
motor feedback cables 419 linear actuators 92
motor power cables 415 linear motors 92
MP-Series electric cylinders 150 rotary motors 20
MP-Series food-grade motors 52 environmental specifications
MP-Series integrated linear stages Kinetix 2000 315
ballscrew 103 Kinetix 3 357
direct drive 106 Kinetix 300 347
MP-Series low-inertia motors 26 Kinetix 6000 293
MP-Series medium-inertia motors 42 Kinetix 6200/6500 267
MP-Series stainless-steel motors 59 Kinetix 7000 331
RDD-Series direct-drive motors 64 linear actuators 91
resistive brake modules 501 linear motors 91
shaft seal kits rotary motors 19
MP-Series food-grade motors 50 Ultra3000 369
MP-Series low-inertia motors 22 Ultra5000 387
MP-Series medium-inertia motors Ethernet cable example 434
38 extension cables 399
MP-Series stainless-steel motors 57 external encoders 471
TL-Series motors 81
shunt modules, external 496
TL-Series electric cylinders 156 F
TL-Series motors 84 features
TL-Series NEMA motors 86 analog servo modules 245
Ultra3000 Bulletin MPAI electric cylinders 183
230V 371, 372 HPK-Series motors 10
460V 373 Kinetix 2000 15
Ultra5000 Kinetix 3 15
230V 388, 389 Kinetix 300 15
460V 390 Kinetix 6000 14
download Motion Analyzer 17 Kinetix 6200/6500 14
drive-end connector kits 455 Kinetix 7000 14
drive-mounted breakout boards 448 LDC-Series linear motors 11, 203
LDL-Series linear motors 11, 223
line interface modules 475
MP-Series ballscrew linear stages 93
MP-Series direct-drive linear stages 93,
110
Notes:
Allen-Bradley, CompactLogix, ControlLogix, ControlNet, DriveExplorer, HPK-Series, Integrated Architecture, Kinetix, LDC-Series, LDL-Series, MicroLogix,
MP-Series, NetLinx, PanelView Plus, POINT I/O, PowerFlex, RSLogix 5000, Rockwell Automation, Rockwell Software, SLC, Stratix 6000, TL-Series, Ultra3000, and
Ultra5000, are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.