0% found this document useful (0 votes)
17 views1 page

Si-100-Monitor de Gas Fijo Senko

The SI-100 is a fixed gas detector designed to measure oxygen, toxic gases, and combustible gases, featuring an LCD display for gas concentration and diagnostic results. It supports various sensors, offers easy operation, and has an explosive-proof and water/dust-proof structure. The device includes automatic calibration, long-distance transmission capabilities, and operates within a wide temperature and humidity range.

Uploaded by

Daniel Godoy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views1 page

Si-100-Monitor de Gas Fijo Senko

The SI-100 is a fixed gas detector designed to measure oxygen, toxic gases, and combustible gases, featuring an LCD display for gas concentration and diagnostic results. It supports various sensors, offers easy operation, and has an explosive-proof and water/dust-proof structure. The device includes automatic calibration, long-distance transmission capabilities, and operates within a wide temperature and humidity range.

Uploaded by

Daniel Godoy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

SI-100

Fixed Gas Detector

Description

SI-100 is a fixed gas detector installed in a place where potential gas hazard exists to
measure oxygen, toxic gas and combustible gas. It shows not only the concentration
of gas but also diagnostic result of the unit itself through the LCD display and can be
connected to the controller with a standard 4-20mA analog output communication or RS-
485 digital communication.

Key Feature
• Various sensors can be applied
• Easy operation with a magnetic bar
• Large digital LCD installed with a blue backlight
• Explosive proof structure
• Water/dust proof structure
• Automatic calibration function
• Long-distance transmission by 4-20mA output

Specification
Model SI-100
Measuring gas Combustible Gas Toxic Gas Oxygen
Measuring method Catalytic IR Electrochemical cell Galvanic
Measuring range 0~100%LEL 0~100%LEL ref. page 19 0~30%VOL
Sensor life time > 5 years > 2 years > 2 years < 2 years
Response time <15sec/90% scale <30sec/90% scale ref. page 19 <15sec/90%scale
Resolution 1%LEL 1%LEL ref. page 19 0.1%VOL
Measuring type Diffusion Type
Accuracy ±2%/Full scale
Parameter Control Front 3 magnetic switch(calibration, maintenance, alarm setting)
Operation mode display Visual: LCD alarm display, LCD Backlight, 3 Indicator LED
Measuring value display Digital LCD Display(4-digit)
Alarm display Visual : LCD alarm display, LCD Backlight, Indicator LED
Alarm output signal Relay contact(Max 30Vdc, 5A) when Alarm occurred
Alarm level set Programmable within detection range
Output signal Analog : 4-20mA(Optional: Hart), Digital : RS-485(Option)
PC interace RS_485(Option)
(4-20mA and Power: CVVSB 1.5sq or AWG 20 / 2,500m max),
Cable/Distance
(RS-485 data communication cable: UL2919 RS-485 1pair / 1,200m max)
Conduit connection NPT 3/4" (2way)
Mounting type Wall mount
Program set mode Alarm value(1,2 alarm), Alarm time(instant@delay) 1~30min, Alarm dead band, output on/off
Operating temperature -20ºC ~ +55ºC
Operating humidity 5% to 95% RH(Non-condensing)
Operating power 9~34Vdc 600mA
Material Aluminium, Stainless steel(STS304)
LCD size 55(W) × 30(H) mm
Dimensions 150(W) × 165(H) × 110(D) mm
Weight Standard type: 1.9kg
ATEX Ex d IIC T5 Gb IP65
CSA (Under certification)
Approval
IECEx Ex d IIC T5 IP65
INMETRO Ex d IIC T5 Gb IP65

www.senko-detection.com