The document contains specifications for various air handling units (AHUs) including unit numbers, models, supply air flow rates, cooling and heating capacities, and fan motor power. Each unit has specific notes on mounting orientation and positioning dimensions, emphasizing the need for factory consultation for accurate details. The document also includes version information and approval details from Qingdao Hisense and Hitachi Air-conditioning Systems Co., Ltd.

Uploaded by

Ronalyn Perez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
39 views7 pages

20241008-Capas Tarlac Project-Outline Drawing

The document contains specifications for various air handling units (AHUs) including unit numbers, models, supply air flow rates, cooling and heating capacities, and fan motor power. Each unit has specific notes on mounting orientation and positioning dimensions, emphasizing the need for factory consultation for accurate details. The document also includes version information and approval details from Qingdao Hisense and Hitachi Air-conditioning Systems Co., Ltd.

Uploaded by

Ronalyn Perez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

1 2 3 4 5 6

Supply air
Unit number AHU-LGF-2-1
A A
Unit model HZKTE-13187W4/B500HYNSA
Return air Supply airfow
17000
(m3/h)
Cooling supply
(kW) 87.9
Heating supply
(kW)
B
Supply fan B
motor power 7.5
(kW)
EC fan total
input power
(kW)
Quantity 1
Piping
Right
direction
C
The position of the fan tuyere is for
illustration only, please contact the C
factory for detailed positioning
Note:
1.Methods for differentiating the left/right mounted unit:
If it is a horizontal unit,facing the direction of supply air flow,
one can find the piping direction on the left,then the unit is
Signature Date Management number Date Change Review Approval
left-mounted. Otherwise, it is right-mounted.If it is a vertical Tag
unit, it can be determined by facing the lower supply air flow. Design Change record
2.The positioning dimensions not indicated in the drawings are only
for illustrative purposes. Please contact the factory for accurate Note Views Ratio Classification Standard Artwork Version
positioning dimensions. Review
A4 0 D
D
Process
Standardize Description Qingdao Hisense Drawing No.
Database version number: 20240906 Hitachi Air-conditioning
Software version No.:V2.0.6 Approval
Systems Co., Ltd. H

1 2 3 4 5 6
1 2 3 4 5 6

Supply air
Unit number AHU-GF-1
A A
Unit model HZKTE-20257W4/B500HYNSA
Return air

Supply airfow
37400
(m3/h)
Cooling supply
(kW) 193.4
Heating supply
(kW)
B
Supply fan B
motor power 15
(kW)
EC fan total
input power
(kW)
Quantity 1
Piping
Right
direction
C
The position of the fan tuyere is for
illustration only, please contact the C
factory for detailed positioning
Note:
1.Methods for differentiating the left/right mounted unit:
If it is a horizontal unit,facing the direction of supply air flow,
one can find the piping direction on the left,then the unit is
Signature Date Management number Date Change Review Approval
left-mounted. Otherwise, it is right-mounted.If it is a vertical Tag
unit, it can be determined by facing the lower supply air flow. Design Change record
2.The positioning dimensions not indicated in the drawings are only
for illustrative purposes. Please contact the factory for accurate Note Views Ratio Classification Standard Artwork Version
positioning dimensions. Review
A4 0 D
D
Process
Standardize Description Qingdao Hisense Drawing No.
Database version number: 20240906 Hitachi Air-conditioning
Software version No.:V2.0.6 Approval
Systems Co., Ltd. H

1 2 3 4 5 6
1 2 3 4 5 6

Supply air

Unit number AHU-GF-2


A A
Return air Unit model HZKTE-28347W4/B500HYNSA
Supply airfow
68000
(m3/h)
Cooling supply
(kW) 351.6
Heating supply
(kW)
B
Supply fan B
motor power 30
(kW)
EC fan total
input power
(kW)
Quantity 1
Piping
Right
direction
C
The position of the fan tuyere is for
illustration only, please contact the C
factory for detailed positioning
Note:
1.Methods for differentiating the left/right mounted unit:
If it is a horizontal unit,facing the direction of supply air flow,
one can find the piping direction on the left,then the unit is
Signature Date Management number Date Change Review Approval
left-mounted. Otherwise, it is right-mounted.If it is a vertical Tag
unit, it can be determined by facing the lower supply air flow. Design Change record
2.The positioning dimensions not indicated in the drawings are only
for illustrative purposes. Please contact the factory for accurate Note Views Ratio Classification Standard Artwork Version
positioning dimensions. Review
A4 0 D
D
Process
Standardize Description Qingdao Hisense Drawing No.
Database version number: 20240906 Hitachi Air-conditioning
Software version No.:V2.0.6 Approval
Systems Co., Ltd. H

1 2 3 4 5 6
1 2 3 4 5 6

Supply air
Unit number AHU-GF-3
A A
Unit model HZKTE-16217W4/B500HYNSA
Return air
Supply airfow
23800
(m3/h)
Cooling supply
(kW) 123.06
Heating supply
(kW)
B
Supply fan B
motor power 11
(kW)
EC fan total
input power
(kW)
Quantity 1
Piping
Right
direction
C
The position of the fan tuyere is for
illustration only, please contact the C
factory for detailed positioning
Note:
1.Methods for differentiating the left/right mounted unit:
If it is a horizontal unit,facing the direction of supply air flow,
one can find the piping direction on the left,then the unit is
Signature Date Management number Date Change Review Approval
left-mounted. Otherwise, it is right-mounted.If it is a vertical Tag
unit, it can be determined by facing the lower supply air flow. Design Change record
2.The positioning dimensions not indicated in the drawings are only
for illustrative purposes. Please contact the factory for accurate Note Views Ratio Classification Standard Artwork Version
positioning dimensions. Review
A4 0 D
D
Process
Standardize Description Qingdao Hisense Drawing No.
Database version number: 20240906 Hitachi Air-conditioning
Software version No.:V2.0.6 Approval
Systems Co., Ltd. H

1 2 3 4 5 6
1 2 3 4 5 6

Supply air

Unit number AHU-2F-1


A A
Return air Unit model HZKTE-25317W6/B500HYNSA
Supply airfow
57800
(m3/h)
Cooling supply
(kW) 299
Heating supply
(kW)
B
Supply fan B
motor power 22
(kW)
EC fan total
input power
(kW)
Quantity 1
Piping
Right
direction
C
The position of the fan tuyere is for
illustration only, please contact the C
factory for detailed positioning
Note:
1.Methods for differentiating the left/right mounted unit:
If it is a horizontal unit,facing the direction of supply air flow,
one can find the piping direction on the left,then the unit is
Signature Date Management number Date Change Review Approval
left-mounted. Otherwise, it is right-mounted.If it is a vertical Tag
unit, it can be determined by facing the lower supply air flow. Design Change record
2.The positioning dimensions not indicated in the drawings are only
for illustrative purposes. Please contact the factory for accurate Note Views Ratio Classification Standard Artwork Version
positioning dimensions. Review
A4 0 D
D
Process
Standardize Description Qingdao Hisense Drawing No.
Database version number: 20240906 Hitachi Air-conditioning
Software version No.:V2.0.6 Approval
Systems Co., Ltd. H

1 2 3 4 5 6
1 2 3 4 5 6

Supply air
Unit number AHU-2F-2
A A
Unit model HZKTE-19257W4/B500HYNSA
Return air

Supply airfow
34000
(m3/h)
Cooling supply
(kW) 175.8
Heating supply
(kW)
B
Supply fan B
motor power 15
(kW)
EC fan total
input power
(kW)
Quantity 1
Piping
Right
direction
C
The position of the fan tuyere is for
illustration only, please contact the C
factory for detailed positioning
Note:
1.Methods for differentiating the left/right mounted unit:
If it is a horizontal unit,facing the direction of supply air flow,
one can find the piping direction on the left,then the unit is
Signature Date Management number Date Change Review Approval
left-mounted. Otherwise, it is right-mounted.If it is a vertical Tag
unit, it can be determined by facing the lower supply air flow. Design Change record
2.The positioning dimensions not indicated in the drawings are only
for illustrative purposes. Please contact the factory for accurate Note Views Ratio Classification Standard Artwork Version
positioning dimensions. Review
A4 0 D
D
Process
Standardize Description Qingdao Hisense Drawing No.
Database version number: 20240906 Hitachi Air-conditioning
Software version No.:V2.0.6 Approval
Systems Co., Ltd. H

1 2 3 4 5 6
1 2 3 4 5 6

Supply air
Unit number AHU-3F-1&2 / 4F-1&2 / 5G-1&2
A A
Unit model HZKTE-19237W4/B500HYNSA
Return air

Supply airfow
30600
(m3/h)
Cooling supply
(kW) 158.22
Heating supply
(kW)
B
Supply fan B
motor power 15
(kW)
EC fan total
input power
(kW)
Quantity 6
Piping
Right
direction
C
The position of the fan tuyere is for
illustration only, please contact the C
factory for detailed positioning
Note:
1.Methods for differentiating the left/right mounted unit:
If it is a horizontal unit,facing the direction of supply air flow,
one can find the piping direction on the left,then the unit is
Signature Date Management number Date Change Review Approval
left-mounted. Otherwise, it is right-mounted.If it is a vertical Tag
unit, it can be determined by facing the lower supply air flow. Design Change record
2.The positioning dimensions not indicated in the drawings are only
for illustrative purposes. Please contact the factory for accurate Note Views Ratio Classification Standard Artwork Version
positioning dimensions. Review
A4 0 D
D
Process
Standardize Description Qingdao Hisense Drawing No.
Database version number: 20240906 Hitachi Air-conditioning
Software version No.:V2.0.6 Approval
Systems Co., Ltd. H

1 2 3 4 5 6

You might also like