Honeywell
IQ 3 Controller Overview
Course Objective
Honeywell
Introduction Hardware Ethernet Network Configuration Setup Portable Display Panel Supervisor Software Interface Field devices
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
INTRODUCTION
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Ethernet TCP/IP Networks
Introduction to TCP/IP
Honeywell
Ethernet TCP/IP is a suite of protocols Original intent of development was to have multiple routes which could be used by computers communicating with each other. Developed by the US Department of Defence in 1973, mainly for the purpose of interconnecting different brands of computers. TCP/IP is a non- proprietary product and is now the accepted communication protocol on the Internet For more details on TCP/IP, visit the following website:
http://www.cisco.com
TCP = Transmission Control Protocol IP = Internet Protocol
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND Ethernet TCP/IP Networks
Why TCP/IP network ?
Market Factor
Honeywell
Demand for simple and fast information access WWW becoming de-facto standard for B2B connectivity Total data connectivity (http, xml,.etc) Distribution of live information (mobile devices etc.) Open solution with lowest proprietary content (harness the IT and Web world of solutions) Increasing regulations Energy issues (Part L, Carbon taxes, cost volatility, etc.) requiring control solutions Changing building infrastructure On-line buildings linked directly to the Internet Flood-wired Ethernet networks becoming standard inside buildings
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Ethernet TCP/IP Networks
Why TCP/IP network ?
Employing Ethernet in Building Solution
Honeywell
IT / Web-based technology is widely implemented all over the world. Most widely used OPEN protocol network. Even more popular than BACnet, LONwork, MODbus, etc. Make use of building or structure existing IT backbone setup. Reduce cost and installation works. The smartest and best cost means of liberating field data for both operators and other information systems. Move away from expensive but slow Lease Line. Move away from a typical Building Management System network. No need of expensive software or specialised hardware for remote access. Using commonly available web-browser for access such as INTERNET EXPLORER
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Ethernet TCP/IP Networks
Why TCP/IP network ?
Advantages
Honeywell
Web enabled: Makes it easy to access and control the building, in real-time, from a standard Web browser Managers and operators can remotely; find out whats going on in their buildings, take rapid action to help manage costs, correct comfort problems, etc.
WWW
From anywhere, ... at anytime
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Ethernet TCP/IP Networks
TREND Strategy..
Creating a Web-based Technology System Web-
Honeywell
IT level
Use IP networking as far down the system as is economically viable Build native embedded web-serving capability as far down the system as is economically viable And ultimatelyManagement and IT level communications in IT compatible formats
Management level Control level Field level
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND IQ 3xx Controllers
INTRODUCTION
IQ 3 XCITE : WHAT IS IT ?
Honeywell
A new platform controller
Uses Ethernet and TCP/IP networking technologies, IT network enable, accessible from anywhere. Built- webBuilt-in web-server, no proprietary software required to access controller or view user specified web pages Modular Hardware Extendibility and Flexibility, up to 96 Input / Output points Flexible number of strategy modules Controllers optimised to application DIN Rail Mounted Backward compatibility with predecessor controllers IQ2 series of controller
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND IQ 3xx Controllers
Types of TREND IQ 3xx Controller :
(A) IQ 3Xact Series
Controller IQ3xact/12 IQ3xcite/16
Honeywell
Inputs & Outputs 6 Analogue outputs & 6 Universal inputs 6 Analogue outputs & 10 Universal inputs only 6 Analogue outputs & 10 Universal inputs Plus up to 80 extra points via I/O expansion modules
TREND IQ 3Xact Controller
IQ3xcite/96
(B) IQ 3Xcite Series
TREND IQ 3Xcite Controller Non-Expandable
TREND IQ 3Xcite Controller Expandable
B U I L D I N G S Y S T E M S
10
N O V A R
I N T E L L I G E N T
File Number
TREND IQ 3xx Series Controller
TREND IQ 3Xcite Expandable CONTROLLER
Input / Output Modules :
Honeywell
Modules is connected via a rigid connector or Belden cable 3084A for up to 30 metres Maximum up to 15 boards can be fitted, limited to an additional of 80 Input / Output points The following module board are available :
Note Xcite 16DI module and Xcite 8DI module can accept both voltage free contact and 24 Vac supply.
11
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND Ethernet System
System Architecture :
Honeywell
3 Levels Hierarchy
TREND Supervisor Software
Management Level Field Controller Level Field Devices Level
Management / Integration Level
Peer-toPeer-to-Peer, Distributed System
TREND IQ 3xx Controller
Intelligence in Every Controller
Network or Standalone Operation Compatible with Standard Protocols BACnet/IP LONworks Open Protocol Communication (OPC)
N O V A R I N T E L L I G E N T
DDC / Field Controller Level
TREND Devices Sensors
Actuators
Field Devices Level
12
B U I L D I N G
S Y S T E M S
File Number
Introduction to TREND IQ 3XCITE Controller Honeywell
IQ 3XCITE FEATURES
Standard TREND IQ Controller Features
Ethernet Platform
BuiltBuilt-in microprocessor, intelligence in every controller. MCF 5272 microprocessor, speed 66MHz Memory 16 Mbytes SDRAM & 8 Mbytes Flash Built-in Real Time Clock BuiltNo replaceable fuse required. Protected by a self resetting thermal solid state breaker Auto-restart capabilities AutoPeer-toPeer-to-Peer Controller Share Global Data among the Ethernet network
IQ 3XCITE
IQ 3XCITE
Network or stand-alone operation stand Ideal for individual or small equipment application for stand-alone operation stand Able to support up to more than 13,400 controllers in a single network, sufficient for large building services or application.
N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S
13
File Number
Introduction to TREND IQ 3XCITE Controller Honeywell
IQ 3XCITE FEATURES
Standard TREND IQ Controller Features
Fully programmable to suit different application Proportional Integral Derivatives Control Boolean Algebraic & Logic Module Function Modules Optimisation Start/Stop Control Plant Rotation / Duty Cycling Sequential Control Etc. Optional Portable Display Panel Smart Display Panel (SDU) IQVIEW (Network Display Panel)
IQVIEW
SMART DISPLAY UNIT
14
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Introduction to TREND IQ 3XCITE Controller Honeywell
IQ 3XCITE FEATURES
Standard TREND IQ Controller Features
Comply to Different Standards UL Listed Standard (24 Vac) EN Standards (100 230Vac) BSI Standard : BS EN ISO 9001:2000 CE Certified Electromagnetic Compatibility Directive (89/336/EEC) Low Voltage Directive (73123/EEC)
15
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Introduction to TREND IQ 3XCITE Controller Honeywell
IQ 3XCITE FEATURES
Additional Features
Faster Network speed Ethernet 10 Base T Network Network baud rate up to 10 Mbytes/sec No memory battery back-up required. back All strategy and data stored in non-volatile memory nonBuiltBuilt-in Web browser Capability
Use commonly available web-browser for access web-
16
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Introduction to TREND IQ 3XCITE Controller Honeywell
IQ 3XCITE FEATURES
Additional Features
Individual Time Scheduling capabilities Allow more than 5 time zones per controller Unlimited number of switching per 24 hours duration period Incorporate override facilities for special events
Enhance security features More than 6 user can be set up Maximum up to 99 access level Support alphanumeric password up to 30 characters Automatic sign-off capabilities
17
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Introduction to TREND IQ 3XCITE Controller Honeywell
IQ 3XCITE FEATURES
Additional Features
Enhance Alarm handling capabilities
Points in alarms will be highlighted in web pages Retransmit alarm to Supervisor software via IP address Retransmit alarm via SMTP to email server address
Additional LED Indicator
Power Indicator (Status & Fault) Watchdog Indicator (Software & RAM fault) Input / Output Bus Indicator (I/O Module Bus fault) Input / Output Terminal Indicator Network Transmission Indicator
18
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
HARDWARE
19
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND IQ 3xx Controllers
Hardware Physical Layout
Honeywell
Optional Battery Card If an IQ 3Xcite Controller is set up to be a time master, an optional battery card is recommended to be installed. The battery shall help to maintain the Real Time Clock (RTC) for several years. However it need to be replaced every 5 years.
N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S
20
File Number
TREND IQ 3xx Controllers
Battery Back-up (Optional)
Battery Card Real Time Clock
Battery Card The optional battery card is used only to maintained the Real Time Clock. As memory is stored in Flash, hence no battery required.
Honeywell
IQ 3Xcite Battery Card
21
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND IQ 3xx Controllers
Controller Power Supply
Honeywell
Power Supply : 100 ~ 230 Vac
Power Supply : 24 ~ 36 Vdc
22
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND IQ 3xx Controllers
Controller Interface
Honeywell
23
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND IQ 3xx Controllers
Controller Data Storage
Honeywell
24
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND IQ 3xx Controllers
Hardware Physical Layout
Expandable Module
Module Address Switch
Honeywell
BUS I/O Connection
Power Supply
25
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND IQ 3xx Controllers
Hardware Physical Layout
Expandable Module Range
8 Channel Module
Honeywell
26
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND IQ 3xx Controllers
Hardware Physical Layout
Expandable Module Range
4 Channel Module
Honeywell
27
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND IQ 3xx Controllers
Hardware Physical Layout
Expandable Module Range
16 Channel Module
I/O Modules
Honeywell
28
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND IQ 3xx Series Controller
Expandable Module
Rigid Connector
Honeywell
End-ofEnd-of-Line Terminator
Adjacent Rigid Inter-connector Inter-
29
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND IQ 3xx Series Controller
Expandable Module
Cable Connector
Honeywell
Wire Connector (terminator)
30
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND IQ 3xx Controllers
Auxiliary Power Supply 24Vdc
Honeywell
31
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND IQ 3xx Controllers
Power Supply (I/O Modules)
Honeywell
32
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND IQ 3xx Controllers
Power Supply (I/O Modules)
Honeywell
24 Vdc Power Supply (max 1.3 A) 24 Vdc Power Supply (max 2.5 A) 24 Vdc Power Supply (max 5 A)
33
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
ETHERNET NETWORKS
34
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Ethernet Networks
TREND Ethernet Networks
IQ 3 series controller
Honeywell
SUPERVISOR
Uses Ethernet and TCP/IP networking technologies, IT network enable, accessible from anywhere.
IQ 3XCITE TREND ETHERNET
WAN
35
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Ethernet Networks
Physical Medium
Network Cable
Honeywell
10 Base T Use a Physical STAR Topology, but uses a Logical BUS Topology for communication Device attach to HUB using a CAT3 or higher twisted pair cable HUBs & devices have LINK LED which indicates the segment is healthy Expand the network by daisy chaining HUB, Other similar networks in this style 100 Base T CAT5 (100Mbytes/s) 1000 Base T CAT6 (1Gbytes/s)
36
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Ethernet Networks
Physical Medium
Network Cable
Types of cable (Ethernet)
Honeywell
37
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Ethernet Networks
Physical Medium
TREND Ethernet Devices (Industrial Rate)
Honeywell
Industrial rate network equipment is designed to operate in harsh industrial environmental. DIN rail mounting and suitable for use in controller enclosure
TREND EDA-205 5 port switch
TREND EDS-305 5 port switch 4 x 10/100 Base T & 1 x 100 Base T
TREND IMC-101 Media Convertor 10/100 Base T to 100 Base Fx
EDAEDA-205 5 port Ethernet Switch EDSEDS-305 5 port Ethernet Switch
38
IMCIMC-101 Media Convertor
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Configuration
Web Pages Configuration
Introduction
Honeywell
IQ 3 controllers incorporate a web server which can deliver user-specific pages to a usercomputer running standard internet browser software.
IQ 3XCITE
39
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Configuration
Web Pages Configuration
Welcome Page
Honeywell
IQ 3 controllers incorporate a web server which can deliver user-specific pages to a usercomputer running standard internet browser software.
40
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Configuration
Web Pages Configuration
Module Page
Honeywell
Module page options allows the user to see the controller strategy. Values can be changed with the keyboard and sent with eitherEnter or one of the adjustment icons.
41
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Configuration
Web Pages Configuration
Plant GraphIQs
Honeywell
Using Display & Directory Modules we can create Plant Graphics
42
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Configuration
Web Pages Configuration
Create GraphIQs
Honeywell
43
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Configuration
Security Configuration
Default System Guest
Honeywell
IQ 3 controllers incorporate a security features to prevent unathuorised access to the parameter of the controller. However, as default, no user is set up at the controller. Although no user is set up, one user still exist; System Guest with L100 (level 100) access). If you do not Log into the IQ 3 controller, you are log in as a System Guest which allow you full access for an unprotected controller
44
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Configuration
Security Configuration
Default System Guest
Honeywell
As soon as you configure a user, the System Guess access level is changed to L-1 L(level -1). Hence basic read only access is given However, user 1 should always be configured at level 99 first and removed last.
System Guest with read-only access read-
45
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Configuration
Security Configuration
Level of Access
Honeywell
Once Users are configured, the module view window will only show appropriate modules depending on level access
46
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
PORTABLE DISPLAY PANEL
47
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Portable Display
Display Panel
Introduction
Honeywell
TREND have provided portable display panel for the new IQ 3 network system
TREND IQ VIEW Display
TREND Smart Display Unit (SDU)
48
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Portable Display
TREND Network Display Panel IQ VIEW Portable Display A touch screen network display panel for interface to the TREND System Features
Honeywell
TREND IQ VIEW Display
Provide a user interface to the TREND IQ system Self-configuration Display graphs View & adjustment of system values View alarms Trend Loop or Ethernet Connection Password user protection
49
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Portable Display
Display Panel
IQ View Overview
Honeywell
50
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Portable Display
Display Panel
IQ View Physical
Honeywell
51
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Portable Display
Display Panel
IQ View Connection
Honeywell
Via the Built-in Vcnc Built-
52
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Portable Display
Display Panel
IQ View Connection
Honeywell
Via third-Party Vcnc third-
53
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Portable Display
TREND Portable Display Panel Smart Display Unit (SDU) A small display panel for interface to the TREND System Features
Honeywell
Electroluminescent 4 x 20 character display Illuminated button for selection or adjustment Allows viewing and adjustment of plant parameters. Display the alarm log Access IQ via supervisor port only.
TREND Smart Display Unit (SDU)
Variant of smart display unit
IQ Current loop controllers IQ Xcite Ethernet controller IQL LON Controllers.
N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S
File Number
54
Honeywell
SUPERVISOR SOFTWARE
55
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Supervisor Software
INTRODUCTION
SUPERVISOR SOFTWARE : WHAT IS IT ?
Honeywell
A real time, user interface independent of the TREND System to allow monitoring and parameter adjustment to the system controllers. Main Features :
Device Viewer Graph Display Password Access Scheduling Capabilities Alarm Management
TREND 963 Supervisor Software
Types of TREND Supervisor Software:
TREND 916 MDS Software
Workstation Supervisor - 963 Supervisor Software Pocket PC Supervisor - 916 Mobile Display Software (MDS)
N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S
File Number
56
Supervisor Software
TREND 963 Supervisor Software
A graphical real-time interface software for monitor / control for the graphical, TREND building system Workstation Supervisor
Honeywell
Features :
Time Schedules
Record Trend Logs
Set-point Adjustment
Schematics Page
Alarm Database
Password Protection
Email Retransmission
Client -Server
57
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND Workstation Supervisor
Available in different version: 963 Lite Most basic package which provide all the fundamental features required of a supervisory package
Honeywell
963 Server Similar facilities with 963 Lite in addition of enabling the 963 to act as a web server allowing access through a web browser software such as Internet Explorer 963 Secure Similar facilities with 963 Lite plus an additional security features to comply to FDA Regulation 21 CPR Part 11 for pharmaceutical application 963 SNMP Similar facilities with 963 Lite plus the capabilities of retransmitting alarm in Simple Network Management Protocol (SNMP) format 963 SMS Direct Similar facilities with 963 Lite plus the capabilities of retransmitting alarm in Short Message Services (SMS) text messaging. GSM modem included
58
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Supervisor Software
TREND 916MDS Software
A portable real-time interface software for monitor / control for the portable, TREND building system Pocket PC Supervisor
Honeywell
Navigator
Monitoring Data
Trend Logs
Alarm Logs
Features Small hand held device true portability Instant operation, fast connection, Any Where Simple interface, easy to train, easy to use Ethernet (wireless), GSM, Bluetooth, Serial connection Trend parameters can be viewed and adjusted
59
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
INTERFACE
60
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Interface Device
TREND Relay Module
Single Relay Module (SRMV) :
Honeywell
Enables a controller analogue voltage output signal to drive a single changeover relay (Digital Output) Maximum resistive load 8 Amps
TREND Single Relay Module Voltage
2 Single Relay Module AC (2 SRM) :
Enables two controller analogue voltage output signal to drive two single changeover relay independently (Digital Output) Maximum resistive load 5 Amps with manual override link
TREND Single Relay Module AC
61
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Interface Device
TREND Signal Converter Module
Two Voltage (V) to two Current (I) Converter Driver Module (2VID)
Honeywell
Converts two channel controller analogue voltage output signal (0 to 10Vdc) to two current output signal (0 mA to 20 mA) Manual override links for aid of commissioning.
TREND 2VID Module
Voltage (V) to Pneumatic Converter Driver Module (PN/VPC)
Converts a controller analogue voltage output signal (0 to 10Vdc) to a proportional pneumatic signal (0.2 bar to 1bar) Requires an external 24 Vac power supply.
TREND PN/VPC Converter Module
62
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
FIELD DEVICES
63
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Field Devices
TREND provides a wide range of field devices to suit the need of many different applications. Range of Field Devices
Honeywell
Field Sensors
Temperature, Humidity, Pressure, Air Quality, Carbon Dioxide, Velocity Differential Pressure Current Transformer, Multi-parameter meter Occupancy Valve, Damper Threaded, Flanged
Field Switches
Electricity Meters
Detectors
Electronic Actuators
Valves
Variable Speed Drive
64
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Field Devices
TREND Wireless Temperature Sensors
Honeywell
Plant Temperature sensor Receiver
coverage of up to 32 sensors with a single receiver covering up to 17,000m2
TREND Wireless Sensor
No cable, no screwdriver, no hassle Simple set-up software Battery life in excess of 5 years
TREND TW/S Sensor
TREND TW/P Sensor
TREND IQ 3Xcite Controller TREND XW/R/IQ Transmitter
65
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Field Devices
TREND LCD Temperature Sensors
Honeywell
Space temperature sensor c/w 3 digit display
Indication & Adjustment of Set-point Indication of fan speed and occupancy
Connect to the controller via supervisor port (T-Bus) Can display reading in either Celsius or Fahrenheit Available in two variants
IQ version : IQ 2xx & IQ 3xx controllers IQL version : IQL controllers
TREND Room Display Unit
66
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Summary
TREND Network Summary
ETHERNET PNC
Honeywell
ENC2
EM/MPO
TMNG
IQ VIEW
GSM
IQ 242
TMNG
LAN LAN CNC2
IQ VIEW
LINC
IQ 3XACT SUPERVISOR
MOBILE SOFTWARE
67
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND System
Typical Building Application
Applications
Honeywell
68
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
THE END
Thank you for your attention
69
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number