PROPOSED RENOVATION OF ELECTRICAL WORKS AT PATANANI SLAUGHTER HOUSE
BILL No. 1: GENERAL PRELIMINARIES
Rate
Item Description Qty Unit Amount (Kshs)
(Kshs)
1.01 Site
The proposed Works will be located at
------------------- , in Kwale County.
1.02 Scope of the works.
The works involve renovation works for
electrical installations
The major work to be carried out in this
contract include the following:
1.General Preliminaries
2.Electrical installations Works
1.03 STORAGE OF MATERIALS -
The Contractor shall provide at his own risk
and cost where directed on the site weather
proof lock-up sheds and make good
damaged or disturbed surfaces upon
completion to the satisfaction of the 1 ITEM 50,000.0 50,000.00
PROJECT MANAGER Nominated Sub-
Contractors are to be made liable for the
cost of any storage accommodation
provided especially for their use.
-
1.04 SECURITY OF WORKS ETC. -
The Contractor shall be entirely responsible
for the security of all the works stores,
materials, plant, personnel, etc., both his
own and sub-contractors' and must provide 1 ITEM 50,000.0 50,000.00
all necessary watching, lighting and other
precautions as necessary to ensure security
against theft, loss or damage and the
protection of the public.
.
1.05 Allow a sum of kshs, 30,000 for sub- 1 Item 30,000 30,000.00
contractors charges for liaison with Kenya
Power & Lighting Company comprising the
following:-
i) Making regular follow-ups with Kenya -
Power & Lighting Company
ii) Facilitating inspection, approvals and -
certification by Kenya Power & Lighting
Company
iv) Providing attendance and materials -
required for power connection.
v) Filling out and submitting -
Commencement and Completion certificates
vi) Performing all other services required
for power supply to site.
Total for Bill No. 1: General preliminaries C/F to Price Summary Page
130,000.00
CGK 1 of 8 Public Works-Electrical section
PROPOSED RENOVATION OF ELECTRICAL WORKS AT PATANANI SLAUGHTER HOUSE
BILL No. 2: Main slaughter
Rate
Item Description Unit Qty Amount (Kshs)
(Kshs)
Supply, install, test and commission
the following:
2.01 LIGHTING INSTALLATION
Lighting points from consumer unit
comprising wiring in 3x 1.5 sqmm SC PVCI
Cu cables in 20mm dia. heavy gauge PVC
conduits concealed in concrete slab/ceilling
and walls excluding other accessories for;-
a) One way switching NO. 25 2,500.00 62,500.00
-
10Amps,moulded plate flush mounted
2.02 switches with screw covers,as CLIPSAL,BG -
or approved equivalent being:-
a) Two gang one way NO. 7 1,000.00 7,000.00
-
2.03 LIGHTING FITTINGS -
1200, 1x 36 Watts batten flourescent fitting
a) chain suspended as FITZGERALD, THORN or NO. 19 3,500.00 66,500.00
approved equivalent
50 Watts,LED spot light as phillips or
b) NO. 6 5,650.00 33,900.00
aprooved equivalent.
-
POWER Power
2.04 13Amps POINTS
points wired ring comprising -
of 3 x 2.5mm sq. single core PVCI copper
a) cables drawn in concealed 25mm HG PVC NO. 6 3,500.00 21,000.00
conduits.
13Amps moulded plate switched socket
b) outlet with neon indicator as BG,CLIPSAL or NO. 6 1,000.00 6,000.00
approved equivalent being Twin
32A TP&N Isolator switch as MK or any
c) other approved equivalent NO 3 8,500.00 25,500.00
32A, TPN+E surface mounted interlocked
switched 3phase socket outlet and complete
d) with plug as MK/MEM/Crabtree or any other NO 3 11,500.00 34,500.00
approved equivalent
Three phase industrial socket outlet point
completely wired in 5x6mm² single core PVC
e) insulated copper cables drawn in 32mm NO. 3 6,500.00 19,500.00
diameter HG PVC conduits including all
accessories but excluding the industrial
socket
CARRIED TO SUMMARY 276,400.00
Rate
Item Description Unit Qty Amount (Kshs)
(Kshs)
CGK 2 of 8 Public Works-Electrical section
PROPOSED RENOVATION OF ELECTRICAL WORKS AT PATANANI SLAUGHTER HOUSE
Brought forward 276,400.00
2.05 FIRE EXTINGUISHER -
Dry chemical powder type fire extinguisher
of 2kgs. Capacity, with initial filling in brand
a) new cylinder with powder coated finish, NO 3 12,000.00 36,000.00
fitted with Gun metal union, high pressure
CO2 gas catridge, discharge hose, wall
mounting bracket e.t.c complete
9 Lts water gas fire extinguisher. Capacity,
b) NO 3 12,000.00 36,000.00
with initial filling in brand
-
SUB MAINS
2.06 Sub-mains CABLES
cables consisting of 50mm² 4- -
Core Armoured cables Thermosetting
insulated CU cables drawn in concealed LM 30 7,200.00 216,000.00
50mm GH PVC conduitsfrom the cable loop-
in-box to the DB
2.07 DISTRIBUTION BOARDS -
6-ways TP&N Distribution Board, flush
mounted,metal cased unit complete with
125Amps TP&N integral mccb and with NO 1 35,850.00 35,850.00
"front hinged lockable metal cover and
glanding chamber to suit as Schneider
Electric or approved equivalent.
-
MCB's to fit in the DB and CCU as
2.08 -
follows and as of Schneider Electric:
a)
10A SP MCB NO 2 1,000.00 2,000.00
32A SP MCB
b) NO 2 1,000.00 2,000.00
32A TP MCB
c) NO 3 4,500.00 13,500.00
SP Spareways
d) NO 2 450.00 900.00
TP Spareways
e) NO 1 550.00 550.00
Electrical Earthing installation to KPLC -
2.09 standards,comprising of; Item 1 10,000.00 10,000.00
(i) 25mm² cu pick insulated E.C.C -
(ii) 6mm² cu bondind lead. -
(iii) 1/2´x1500mm cu earth rod as furze -
(iv) precast concrete inspection pit
320x320x200 as furze -
-
2.10 125A,415V 4- pole MCCB NO 1 32,500.00 32,500.00
-
Total for Bill No. 2: Main Slaughter C/F
661,700.00
to Price Summary Page
CGK 3 of 8 Public Works-Electrical section
PROPOSED RENOVATION OF ELECTRICAL WORKS AT PATANANI SLAUGHTER HOUSE
PRICE SUMMARY PAGE
ITEM DESCRIPTION AMOUNT
SUMMARY PAGE
1.00 Total for Bill No. 1: General preliminaries 130,000.00
2.00 Total for Bill No. 2: Main slaughter 661,700.00
TOTAL A 791,700.00
Add the sum of 5% of Total A for contingencies to be expended in
3.00 39,585.00
whole or in part or deleted as directed by the Engineer
TOTAL B 831,285.0
Add 16% VAT 133,005.60
TOTAL FOR ELECTRICAL WORKS CARRIED TO FORM OF TENDER 964,290.6
CGK 4 of 8 Public Works-Electrical section
PROPOSED RENOVATION OF ELECTRICAL WORKS AT PATANANI SLAUGHTER HOUSE
BILL No. 1: GENERAL PRELIMINARIES
Rate
Item Description Qty Unit Amount (Kshs)
(Kshs)
1.01 Site
The proposed Works will be located at
------------------- , in Kwale County.
1.02 Scope of the works.
The works involve renovation works for
electrical installations
The major work to be carried out in this
contract include the following:
1.General Preliminaries
2.Electrical installations Works
1.03 STORAGE OF MATERIALS -
The Contractor shall provide at his own risk
and cost where directed on the site weather
proof lock-up sheds and make good
damaged or disturbed surfaces upon
completion to the satisfaction of the 1 ITEM
PROJECT MANAGER Nominated Sub-
Contractors are to be made liable for the
cost of any storage accommodation
provided especially for their use.
1.04 SECURITY OF WORKS ETC.
The Contractor shall be entirely responsible
for the security of all the works stores,
materials, plant, personnel, etc., both his
own and sub-contractors' and must provide 1 ITEM
all necessary watching, lighting and other
precautions as necessary to ensure security
against theft, loss or damage and the
protection of the public.
.
1.05 Allow a sum of kshs, 30,000 for sub- 1 Item 30,000 30,000.00
contractors charges for liaison with Kenya
Power & Lighting Company comprising the
following:-
i) Making regular follow-ups with Kenya -
Power & Lighting Company
ii) Facilitating inspection, approvals and -
certification by Kenya Power & Lighting
Company
iv) Providing attendance and materials -
required for power connection.
v) Filling out and submitting -
Commencement and Completion certificates
vi) Performing all other services required
for power supply to site.
Total for Bill No. 1: General preliminaries C/F to Price Summary Page
CGK 5 of 8 Public Works-Electrical section
PROPOSED RENOVATION OF ELECTRICAL WORKS AT PATANANI SLAUGHTER HOUSE
BILL No. 2: Main slaughter
Rate
Item Description Unit Qty Amount (Kshs)
(Kshs)
Supply, install, test and commission
the following:
2.01 LIGHTING INSTALLATION
Lighting points from consumer unit
comprising wiring in 3x 1.5 sqmm SC PVCI
Cu cables in 20mm dia. heavy gauge PVC
conduits concealed in concrete slab/ceilling
and walls excluding other accessories for;-
a) One way switching NO. 25
10Amps,moulded plate flush mounted
2.02 switches with screw covers,as CLIPSAL,BG
or approved equivalent being:-
a) Two gang one way NO. 7
2.03 LIGHTING FITTINGS
1200, 1x 36 Watts batten flourescent fitting
a) chain suspended as FITZGERALD, THORN or NO. 19
approved equivalent
50 Watts,LED spot light as phillips or
b) NO. 6
aprooved equivalent.
POWER Power
2.04 13Amps POINTS
points wired ring comprising
of 3 x 2.5mm sq. single core PVCI copper
a) cables drawn in concealed 25mm HG PVC NO. 6
conduits.
13Amps moulded plate switched socket
b) outlet with neon indicator as BG,CLIPSAL or NO. 6
approved equivalent being Twin
32A TP&N Isolator switch as MK or any
c) other approved equivalent NO 3
32A, TPN+E surface mounted interlocked
switched 3phase socket outlet and complete
d) with plug as MK/MEM/Crabtree or any other NO 3
approved equivalent
Three phase industrial socket outlet point
completely wired in 5x6mm² single core PVC
e) insulated copper cables drawn in 32mm NO. 3
diameter HG PVC conduits including all
accessories but excluding the industrial
socket
CARRIED TO SUMMARY
Rate
Item Description Unit Qty Amount (Kshs)
(Kshs)
CGK 6 of 8 Public Works-Electrical section
PROPOSED RENOVATION OF ELECTRICAL WORKS AT PATANANI SLAUGHTER HOUSE
Brought forward -
2.05 FIRE EXTINGUISHER -
Dry chemical powder type fire extinguisher
of 2kgs. Capacity, with initial filling in brand
a) new cylinder with powder coated finish, NO 3
fitted with Gun metal union, high pressure
CO2 gas catridge, discharge hose, wall
mounting bracket e.t.c complete
9 Lts water gas fire extinguisher. Capacity,
b) NO 3
with initial filling in brand
SUB MAINS
2.06 Sub-mains CABLES
cables consisting of 50mm² 4-
Core Armoured cables Thermosetting
insulated CU cables drawn in concealed LM 30
50mm GH PVC conduitsfrom the cable loop-
in-box to the DB
2.07 DISTRIBUTION BOARDS
6-ways TP&N Distribution Board, flush
mounted,metal cased unit complete with
125Amps TP&N integral mccb and with NO 1
"front hinged lockable metal cover and
glanding chamber to suit as Schneider
Electric or approved equivalent.
MCB's to fit in the DB and CCU as
2.08
follows and as of Schneider Electric:
a)
10A SP MCB NO 2
32A SP MCB
b) NO 2
32A TP MCB
c) NO 3
SP Spareways
d) NO 2
TP Spareways
e) NO 1
Electrical Earthing installation to KPLC
2.09 standards,comprising of; Item 1
(i) 25mm² cu pick insulated E.C.C
(ii) 6mm² cu bondind lead.
(iii) 1/2´x1500mm cu earth rod as furze
(iv) precast concrete inspection pit
320x320x200 as furze
2.10 125A,415V 4- pole MCCB NO 1
Total for Bill No. 2: Main Slaughter C/F
to Price Summary Page
CGK 7 of 8 Public Works-Electrical section
PROPOSED RENOVATION OF ELECTRICAL WORKS AT PATANANI SLAUGHTER HOUSE
PRICE SUMMARY PAGE
ITEM DESCRIPTION AMOUNT
SUMMARY PAGE
1.00 Total for Bill No. 1: General preliminaries
2.00 Total for Bill No. 2: Main slaughter
TOTAL A
Add the sum of 5% of Total A for contingencies to be expended in
3.00
whole or in part or deleted as directed by the Engineer
TOTAL B
Add 16% VAT
TOTAL FOR ELECTRICAL WORKS CARRIED TO FORM OF TENDER
CGK 8 of 8 Public Works-Electrical section