The document describes a high-speed micro centrifuge featuring a double cooling air design, maintenance-free brushless motor, and safety features such as door interlock and automatic diagnostics. It is suitable for various applications in biological, chemistry, and clinical labs, with rotors made from autoclavable aluminum alloy. The centrifuge offers multiple rotor options and specifications, including maximum speed, RCF, and safety devices.

Uploaded by

Abdulfattah Guda
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
6 views

D3024

The document describes a high-speed micro centrifuge featuring a double cooling air design, maintenance-free brushless motor, and safety features such as door interlock and automatic diagnostics. It is suitable for various applications in biological, chemistry, and clinical labs, with rotors made from autoclavable aluminum alloy. The centrifuge offers multiple rotor options and specifications, including maximum speed, RCF, and safety devices.

Uploaded by

Abdulfattah Guda
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

���/ C entrifuges

D3024 Features
High Speed Micro Centrifuge
• Double cooling air design ensures fast cooling of the
rotor and low energy consumption
• �-layer sealed rotors ensure safe centifugation
• Brushless motor drive, maintenance free
• Safety features include door interlock; excessive speed
and temperature detection; automatic self-diagnostics
• Outstanding aluminum alloy rotors fully autoclavable at
���℃ temperature and high pressure disinfection
• Five rotors are optional complete with �� places
�.�/�.�mL tubes,�.�mL, �.�mL and �.�mL tubes with
adapters

Applications
Suitable for numerous biological, chemistry, clinical and
research applications including molecular biology,
clinical chemistry labs, wide variety of microbiology
applications, such as DNA, RNA or protein isolation and
many more.

Brushless DC motor

Wide range of rotors

Effective Ventilation System Conventional design

Double cooling air design, enforcing air Limited ventilation on the upper
cooling from both the upper and lower side of the rotor
side for the rotor.
���/ C entrifuges
DLAB rotors are manufactured from military-industrialgrade
aluminum alloy with high mechanical strength for precise
running and safety (excludes D���� plus rotor) Rotor Features
• Every rotor can reach a maximum Speed of �����rpm Fully autoclavable
• Rotors are seated on a tapered shaft,concentric and
High strength aluminum alloy rotors are fully
self-aligning, perfect to achieve running stability at high autoclavable, withstanding steam sterilizing at
speeds ���°C for �� minutes
• D���� & D����R with three-layer sealed rotors/
anti- sample overflow prevents accidental leakage
• D���� & D����R rotors have passed MCA test according to Three-layer seal
IEC/EN�����-�-��, including mechanical safety and D���� & D����R rotors are designed to prevent
bio-safety tests sample leakage. Each and every rotor is
• Powerful cooling system minimizes rotor heating. D���� hermetically sealed by three rubber seals.
rotors maintain at ��°C and D����R rotors less than �°C
after running an hour Mechanical safety
DLAB centrifuges confirm to MCA standard
Seals within the IEC/EN�����-�-��, causing disruption by partially
cutting and overloading rotor assembly, and
aluminum alloy rotor guarantees that no part shall be detached to cause
Three rubber seals fitted to danger to person or the environment.
achieve bio-safe condition

Specifications D����
Max. Speed �����rpm(���-�����rpm),
increment:��rpm
Max. RCF �����×g, increment:��×g
Speed Accuracy ±�� rpm

Rotor Capacity �.�/�mL��,�.�/�.�mL��,


PCR-� strips�,�mL��,�mL��

Run Time ��sec-��min/Continuous


Acceleration/Braking time [Sec] ��s↑��s↓
Motor Brushless DC motor

Dual door interlock,


Safety Devices Over-speed detection,
Automatic internal diagnosis

Single-phase, AC���V-���V,
Power Requirements ��Hz/��Hz, �A,AC���V-���V,
��Hz/��Hz, �A ���W

Noise Level ≦��dB


Dimension[W×D×H] ���×���×���mm
Weight ��kg

Speed/RCF switch; Short-time


Other functions
run function; sound-alert function
���/ C entrifuges

Available rotors

AS��-� Cat. No.�������� AS��-� Cat. No.��������


(round bottom)
for D���� & D����R for D���� & D����R
Max. speed: �����rpm Max. speed :�����rpm
Max. RCF: �����×g Max. RCF:�����×g
Rotor capacity: Rotor capacity:�mL�� ( Round
�mL/�.�mL��/�.�mL��/�.�mL�� bottom )
Rotor material: Aluminum alloy Rotor material:Aluminum alloy
Biosealing: Yes Biosealing:Yes
Available rotor adapters: A��P�,A��P�

AS��-�V Cat. No.�������� Available adapters


(cone bottom)

for D���� & D����R


Max. speed: �����rpm A��P� Cat. No.��������
Max. RCF: �����×g
�.�mL rotor adapter
Rotor capacity: �mL��(Cone bottom)
Used with A��-�, A��-�P, AS��-� and
Rotor material: Aluminum alloy
A��-�P rotors ��pcs/pk
Biosealing: Yes

AS��-�� Cat. No.��������


for D���� & D����R
Max. speed: �����rpm
A��P� Cat. No.��������
Max. RCF: �����×g
Rotor capacity: �.�mL��,�.�mL�� �.�mL rotor adapter
Rotor material: Aluminum alloy Used with A��-�, A��-�P, AS��-�
Biosealing: Yes and A��-�P rotors
Available rotor adapters: A��P�� ��pcs/pk

AS�-PCR� Cat. No.��������


for D���� & D����R
Max. speed: �����rpm
A��P�� Cat. No.��������
Max. RCF: �����×g �.�mL rotor adapter
Rotor capacity:�.�mL/PCR�� Used with AS��-�� rotor
Rotor material: Aluminum alloy ��pcs/pk
Biosealing: Yes