0% found this document useful (0 votes)
147 views2 pages

RTC-2601022399 2CX1.5

The test report for Polycab India Limited details the specifications and performance of a 1100V flexible industrial cable, confirming compliance with IS 694: 2010 standards. The cable was tested for conductor resistance and HV/spark tests, with all results meeting the required specifications. The report includes observations for two separate tests, both indicating successful performance.

Uploaded by

salesmancab
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
147 views2 pages

RTC-2601022399 2CX1.5

The test report for Polycab India Limited details the specifications and performance of a 1100V flexible industrial cable, confirming compliance with IS 694: 2010 standards. The cable was tested for conductor resistance and HV/spark tests, with all results meeting the required specifications. The report includes observations for two separate tests, both indicating successful performance.

Uploaded by

salesmancab
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Page 1 of 15

POLYCAB INDIA LIMITED


TEST REPORT

Customer
S.O. No. 25262018063 Invoice Number KA711S2526100791
Item Code LDIS09CYUAY1002C1.5SC001S Date 02-MAY-2025
SIZE 2C X 1.5 SQ MM Quantity 50
Voltage Grade 1100V Color BLACK
POLYCAB MAKE 1100 V FLEXIBLE (CLASS 5) BARE COPPER CONDUCTOR, PVC (TYPE D) INSULATED, AND EXTRUDED PVC (TYPE ST3) OUTER
Description
SHEATHED INDUSTRIAL CABLE GEN. AS PER IS 694 .

SR. NO. DESCRIPTION UNITS REQUIREMENTS OBSERVATIONS


1 Specification - IS 694: 2010 IS 694: 2010
Core Colour - Black Black
Conductor Resistance @ 20°C OPK Max : 13.30 13.26
HV/Spark Test of Cable KV 3 kv AC for 5 Minutes / online spark testing Withstood
2 Specification - IS 694: 2010 IS 694: 2010
Core Colour - Red Red
Conductor Resistance @ 20°C OPK Max : 13.30 13.24
HV/Spark Test of Cable KV 3 kv AC for 5 Minutes / online spark testing Withstood
Overall Diameter/Dimensions of cable MM Max : 8.9 7.14
Note: The Cable has been tested for above tests and found meeting the requirements, as per IS 694: 2010

Tested By: Yugdip Uttekar Approved By: Kajal Salui


Page 2 of 15

POLYCAB INDIA LIMITED


TEST REPORT

Customer
S.O. No. 25262018063 Invoice Number KA711S2526100791
Item Code LDIS09CYUAY1002C1.5SC001S Date 02-MAY-2025
SIZE 2C X 1.5 SQ MM Quantity 50
Voltage Grade 1100V Color BLACK
POLYCAB MAKE 1100 V FLEXIBLE (CLASS 5) BARE COPPER CONDUCTOR, PVC (TYPE D) INSULATED, AND EXTRUDED PVC (TYPE ST3) OUTER
Description
SHEATHED INDUSTRIAL CABLE GEN. AS PER IS 694 .

SR. NO. DESCRIPTION UNITS REQUIREMENTS OBSERVATIONS


1 Specification - IS 694: 2010 IS 694: 2010
Core Colour - Black Black
Conductor Resistance @ 20°C OPK Max : 13.30 13.25
HV/Spark Test of Cable KV 3 kv AC for 5 Minutes / online spark testing Withstood
2 Specification - IS 694: 2010 IS 694: 2010
Core Colour - Red Red
Conductor Resistance @ 20°C OPK Max : 13.30 13.22
HV/Spark Test of Cable KV 3 kv AC for 5 Minutes / online spark testing Withstood
Overall Diameter/Dimensions of cable MM Max : 7.6 6.78
Note: The Cable has been tested for above tests and found meeting the requirements, as per IS 694: 2010

Tested By: Kuldipsinh Parmar Approved By: Nitin Neve