D711en MegaPulse70plus
D711en MegaPulse70plus
Power.
Developed to impress. MegaPulse 70+ offers superior frequency and energy, and an EXPERT Mode,
which allows the user to select pulse lengths on an individual basis.
Flexibility.
The MegaPulse 70+ laser is ideal for stone and BPH treatment in urology
as well as other interventions across a range of specialties:
Usability.
Intuitive and convenient handling allows the user to easily navigate between three different clinically-tested modes.
02
LITHOTRIPSY
EXPERT
SOFT TISSUE
03
Fast and effective stone treatment
LITHOTRIPSY
Working with the MegaPulse 70+ laser in LITHOTRIPSY Mode The user can select settings to favor fragmentation
is convenient and effective.This mode offers different presets (setting: "Power Fragmentation"), dusting (setting: "Dusting",
depending on the location and the characteristics of a stone. "Power Dusting") or popcorning (setting: "Popcorning").
Thanks to its high frequency and energy, the MegaPulse 70+ laser can be used for fast and effective stone
therapy therefore representing a high-speed system for lithotripsy.
Used in conjunction with endoscopic instruments, the laser can effectively disintegrate stones within the
bladder, ureter, urethra, or kidney.
04
Precision ablation
SOFT TISSUE
Designed with a focus on details, SOFT TISSUE Mode sets a Presets guarantee optimized cutting power depending on
new standard in precision and speed compared to the characteristics of a tissue.The user can choose between
conventional methods. "Forced Cut", "Standard Cut", and "Precise Cut" in order to
receive the optimal setting.
SOFT TISSUE Mode’s optimized frequency and energy settings yield perfect results with "only" 70 W –
e.g. in the case of a Holmium laser enucleation of the prostate (HoLEP).
MegaPulse 70+ is also suitable for ablation or resection of bladder, urethral and ureteral tumors, t ransurethral
incision of the prostate (TUIP), slitting of urethral structures, ablation of condylomas, and incision of the
bladder neck.
05
06
Custom pulse selection
EXPERT
MegaPulse 70+ offers experienced users the option to select Depending on the type of treatment a short pulse can initiate
the pulse width in three stages – short, middle and long.This effective stone fragmentation whereas a long pulse can
covers a broad spectrum of 50 μs – 1100 μs. achieve excellent hemostasis during treatment of BPH.
megapulse70plus.richard-wolf.com
Within EXPERT Mode the user has the flexibility to adjust settings
according to individual requirements.
„This is a really good laser.
Just hit the pedal and have fun!“
Dr. med. Michael Straub // Managing
Senior Physician, Director of Endourology
and Urinary Stone Therapy, Rechts der Isar
Hospital, Munich
07
Power. Flexibility. Usability.
MegaPulse 70+, with all its innovative features, offers the surgeon
and staff maximum versatility.
History of use
The system recognizes how often a laser fiber has been
used and how many more times the fiber can be reused
until it must be replaced.
08
The beauty is in the details
A large number of small details significantly enhance
handling with the MegaPulse 70+ laser, increase safety and
also save time in the operating room.
09
Complete
in lithotripsy
LITHOTRIPSY
MAMBA vision
With the addition of the new flexible
MAMBA vision sensor cystoscope
Richard Wolf now offers a full portfolio
of flexible sensor endoscopes.
COBRA vision
The unique dual channel COBRA
vision flexible sensor ureteroreno-
scope (URS) is ideal for stone therapy.
BOA vision
BOA vision is a single channel, flexible
sensor ureterorenoscope with a slim
8.7 Fr. diameter that can fit through a
9.5 Fr. access sheath and can there-
fore be used as an all-rounder particu-
larly in case of difficult and small The Richard Wolf turnkey package
anatomies. comprises:
10
Complete
in BPH therapy
SOFT TISSUE
PIRANHA Morcellator
The atraumatic distal tip of the
PIRANHA Morcellator is open at
the top and prevents the mucus mem-
brane of the bladder from being
sucked by mistake.
11
Ordering Information
Subject to modifications. Please note that some products may not be available in all countries. Please always take note of the information that is provided with the product.
Laser type Holmium:YAG Laser (Ho:YAG)
Wavelength 2100 nm (2.1 µm)
Mode of operation pulsed
Voltage 200 – 230 V, 50/60 Hz, < 32 A Laser fibers
Energy 200 mJ – 5000 mJ Core diameter Disposable Reusable (10x)
Frequency / rate 3 – 60 Hz opt. fiber performance
OFC402011 OFC402013
200 µm
Pulse duration adjustable (50 µs – 1100 µs)
optical fiber 200 µm OFC002011 OFC002013
green: 532 nm, < 5 mW,
Pilot beam adjustable to continuous optical fiber ball tip
OFC302711 –
or flashing 272 μm
Max. operating temperature 10°C – 30°C optical fiber 272 µm OFC702711 OFC702713
For more detailed information, please consult with your contact partner or directly with Richard Wolf GmbH.
Storage temperature min. + 5°C, max. 40°C optical fiber 365 µm OFC703611 OFC703613
Dimensions (W x H x D) 595 x 1200 x 1074 mm optical fiber 550 µm OFC005511 OFC005513
Weight 200 kg optical fiber 800 µm OFC008011 OFC008013
Display 12" touchscreen optical fiber 1000 µm OFC009911 OFC009913
Richard Wolf GmbH Tel.: +49 7043 35-0 Co-CEOs: Trade Register: Mannheim HRB 510031
Pforzheimer Straße 32 Fax: +49 7043 35-4300 Jürgen Pfab VAT no.: DE144521586
75438 Knittlingen, Germany [email protected] Jürgen Steinbeck Tax no.: 48020/00171