0% found this document useful (0 votes)
49 views1 page

Outdoor Power Distribution Panel Location: JFGP, 3Gcp (Typ) : Saudi Arabian Oil Company

The document outlines specifications for electrical equipment and systems for Saudi Aramco, including requirements for circuit breakers, MOVs, and outdoor power distribution panels. It emphasizes the need for compliance with safety standards, such as NEMA ratings and IECEx certification for hazardous areas. Additionally, it notes that detailed design checks and updates are necessary for existing switch racks and electrical load schedules.

Uploaded by

faisalqr
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views1 page

Outdoor Power Distribution Panel Location: JFGP, 3Gcp (Typ) : Saudi Arabian Oil Company

The document outlines specifications for electrical equipment and systems for Saudi Aramco, including requirements for circuit breakers, MOVs, and outdoor power distribution panels. It emphasizes the need for compliance with safety standards, such as NEMA ratings and IECEx certification for hazardous areas. Additionally, it notes that detailed design checks and updates are necessary for existing switch racks and electrical load schedules.

Uploaded by

faisalqr
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

SAUDIARAMCO.

NOTES:

1. ALL CIRCUIT BREAKER SHALL BE THERMAL MAGNETIC


RATED FOR 50°C AMBIENT TEMPERATURE AS PER
480V INCOMING POWER SUPPLY
SAES-P-100 TABLE-3.
FROM SWITCHRACK 863-009-SR-001
@JFGP IMPORT SCRAPER AREA 2. EACH MOV HAS AN INTEGRAL STARTER AND LOCAL

REFER DWG.NO. TD-704414-001 CONTROL STATION WITH OPEN/STOP/CLOSE

(NOTE-9) PUSHBUTTON, LOCAL-OFF-REMOTE SELECTOR SWITCH


IP-JP2L1-P-T5800 & POSITION INDICATOR.

OF
3. ADEQUACY CHECK ON EXISTING SWITCHRACK

CONSENT
Q80-SR-009 TO BE PERFORMED DURING DETAILED
DESIGN.
PC-0200
4. BATTERY CHARGER & RECTIIER FOR 24V DC POWER
SUPPLY TO INSTRUMENTATION (ESD/RTU) AND TELECOM
OUTDOOR POWER DISTRIBUTION PANEL LOCATION: JFGP, 3GCP (TYP)
LOADS. BATTERY CHARGER RATING SHALL BE
FINALIZED DURING DETAIL DESIGN.

TTEN
5. ENCLOSURE LOCATED OUTDOORS SHALL BE DUST
TIGHT, WATERTIGHT (METALLIC NEMA 4 OR IP66

WRI
875-009-PP-001 (NOTE-10) NEMA-4X EQUIVALENT).

6. EQUIPMENT IN HAZARDOUS AREA SHALL BE DUST


DEMAND LOAD - 38.292kVA

THE
TIGHT, WATERTIGHT (METALLIC NEMA 4 OR IP66
EQUIVALENT) AND SHALL ALSO BE IECEx CERTIFIED
100AT FOR USE IN CLASSIFIED AREAS.

THOUT
3P
100AF
7. EQUIPMENTS LOCATED IN CORROSIVE ATMOSPHERES
SHALL BE METALLIC ENCLOSURE NEMA 4X (IP66
EQUIVALENT WITH CORROSION PROTECTION).

WI
480V, 100A, BUS, 3PH, 3 WIRE, 60HZ, 14KAIC
8. TAG NUMBER FOR ALL ELECTRICAL EQUIPMENT ARE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

NG
TEMPORARY AND NEED TO BE UPDATED DURING

DRAWI
DETAILED DESIGN THROUGH PROPER RESERVATION
FROM I-PLANT.

20AT 20AT 20AT 20AT 20AT 20AT 30AT 20AT 20AT 20AT 20AT 20AT 30AT 9. POWER SUPPLY TO POWER PANEL 875-DXX-PP-0001
3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P
100AF 100AF 100AF 100AF 100AF 100AF 100AF 100AF 100AF 100AF 100AF 100AF 100AF SHALL BE FED FROM EXISTING SWITCHRACK
G

S
G 863-SS09-SR-001 AT 3 GCP AND JFGP.

THI
10. ALL THE DISTRIBUTION PANELS SHALL BE
SEGREGATED BUS.

FROM
11. MOV'S SHALL BE RATED FOR 480V AC, 60Hz,
3 PHASE POWER SUPPLY AS PER 34-SAMSS-716
CLAUSE 9.

NED
12. ALL LOAD AND EQUIPMENT SHORT CIRCUIT ARE

OBTAI
SPARE SPARE SPARE SPARE SPACE SPACE PRELIMINARY AND TO BE VERIFIED DURING DETAILED
PC-0202 PC-0203 PC-0204 PC-0206 PC-0207 PC-0208 PC-0209 PC-0210 PC-0212 DESIGN ENGINEERING BY EPC CONTRACTOR.

-0001
TCH

30A,480V,3P,60HZ
13. LOW VOLTAGE PANELBOARDS SHALL BE
MANUFACTURED AS PER SAUDI ARAMCO MATERIAL

SWI

BE
D)
STANDARD 16-SAMSS-518.

875-009-DSW(

PART,SHALL
LEGEND

SCONNECT
DISCONNECT SWITCH

DI
480V, 3-POLE, ENCLOSED
PC-0213
3P
CIRCUIT BREAKER MCCB

N
I
3 3 3 3 3 3 3
HP HP HP HP HP HP HP

FULL,OR
FULL VOLTAGE

ON
-0002
REVERSING STARTER
875-800G-MOV-0023

875-800G-MOV-0024

875-800G-MOV-0025

875-800G-MOV-0027

875-800C-MOV-0030

875-800C-MOV-0031

875-800C-MOV-0032

PROTECTI
NG

IN MOV ENLOSURE
BLOCKI

(BY VENDOR)

T)
875-009-XFR(

N
I ON
ER
25kVA)
NE

C
CATHODI
XX

REPRODUCTI
FI
HP RATING
LI

HP

RECTI
TYP)
GAS

1.
(

(
TRANSFORMER C.P. RECTIFIER

FOR GAS SCRAPER RECEIVER FROM GCP'S FOR CONDENSATE SCRAPER


RECEIVER FROM GCP'S PC-XXXX POWER CABLE TAG NUMBER

SAUDIARAMCO.NO
PC PHOTOCELL C CONTACTOR

875-009-XFR(T)-0001
15kVA, AF AMPERE FRAME AT AMPERE TRIP
480V/400-230V
Dyn 11, Z=4% PP POWER PANEL LG LIGHTING
3PH, 4W, DRY TYPE
TRANSFORMER LCP LIGHTING CONTACTOR PANEL

OF
MOV MOTOR OPERATED VALVE

PC-0216
875-009-PP-002

PROPERTY
NEMA-4X

REV CLOUD DENOTES THE CHANGES WITH


DEMAND LOAD : 2.269kVA RESPECT TO THE PREVIOUS REVISION.
100AT
3P
100AF

SOLE
100A, 400/230V, 3PH, 4W, 60Hz, 10KAIC REFERENCE DRAWINGS
DRAWING CONTROL BI 11-22034-0-1001 XX-XXXXXX
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

THE
ELECTRICAL AREA CLASSIFICATION PP-713452-001

CABLE ROUTING & LIGHTING LAYOUT PP-743452-001

ARE
ELECTRICAL ONE LINE DIAGRAM DC PP-703454-001
20AT 20AT 20AT 20AT 20AT 20AT 20AT 20AT 20AT 20AT 20AT 20AT 20AT
1P 1P 1P 1P 1P 1P 1P 1P 1P 1P 1P 1P 1P ELECTRICAL LOAD SCHEDULE PP-843453-001
100AF 100AF 100AF 100AF 100AF 100AF 100AF 100AF 100AF 100AF 100AF 100AF 100AF
ELECTRICAL CABLE SCHEDULE PP-843454-001

N
S/N GND

HEREI
EXISTING SWITCHRACK DXX-SWRK-0001 XX-XXXXXX

SPARE SPARE SPACE SPACE


D3 02/14/23 abdulghani.khan mukhtar.soliman stuart.dixon

NED
D2 02/06/23 AGK MGS SDX

D1 12/01/22 AGK MGS SDX

CONTAI
875-009-LCP-0001 WOOD DATE BY CH'D APP PLG PRJ PRO HSE CIV C&I ELE COM CON
PC
LIGHTING CONTACTOR PANEL
REVISION VALIDATION

THIS REVISION NO. C IS COVERED, FOR ALL APPROVAL AND CERTIFICATION

REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:

ON
NFORMATI
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)

ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE

PC-0219 PC-0220 PC-0221 PC-0222 PC-0223 PC-0224 PC-0225 PC-0226 PC-0227 TBA TBA

REV.NO. DATE REVISION DESCRIPTION

I
C 02/14/23 ISSUED FOR PROPOSAL

THE
JOB ORDER/EWO NO.
THIS REVISION IS NOT TO BE USED FOR
11-22034-1001 CONSTRUCTION UNTIL CERTIFIED AND DATED

SAUDI ARABIAN OIL COMPANY


PANEL
PANEL

AND
NG
NG

NG

NG

RECEPTACLE-A

RECEPTACLE-B
SUNSHADE

GHTI
875-009-LG-0007
875-009-LG-0008
GHTI

GHTI

GHTI
875-009-LG-0001
875-009-LG-0002

875-009-LG-0003
875-009-LG-0004

875-009-LG-0005
875-009-LG-0006

DRAWING TYPE

ELECTRICAL ONE LINE DIAGRAM E1L

NG
LI

RECEPTACLES
LI

LI

LI
NG

NG

ON
ON

SCRAPER STATION @ JFGP

DRAWI
GHTI

GHTI

BUTI
BUTI

AREA
AREA

AREA

AREA

JAFURAH TRANSMISSION PIPELINE


SHELTER
DED

180VA)

180VA)

180VA)
LI

LI

280W)
280W)

280W)

280W)

STRI
STRI

140W)

210W)

SPARE

SPARE

JAFURAH SAUDI ARABIA


SI

MOV

MOV
LED
LED

LED

LED

LED

LED

S
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

THI
DI
DI

(
(

875 P PP-703456 001 C


502395-8530-70-5056 CLASS:1 Saudi Aramco 2615 ENG. (05/05)