JOB CARD MPD-TASK: 212600-04
JAI - A330 AMM TASK : 21-26-00-710-808-A
21-26-00 PB 501
TITLE:
A/C Reg.: 21-26-00-710-808-A - Operational
VT-JWR Check of the Cooling Effect Detector
CARD: ZONE: 133 INTERVAL:
SKILL: ACCESS:
MECH. INSP.
** ON A/C ALL
TASK 21-26-00-710-808-A
Operational Check of the Cooling Effect Detector
WARNING: MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING
SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE.
HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
1. Reason for the Job
Refer to the MPD TASK: 212600-04
OPERATIONAL CHECK OF COOLING EFFECT DETECTOR (AEVC SYSTEM TEST).
2 Job Set-up Information
A. Work Zones and Access Panels
ZONE/ACCESS ZONE DESCRIPTION
133 U/FLOOR COMPT OF LWR DECK FWD CAR COMPT
B. Referenced Information
REFERENCE DESIGNATION
(Ref. 24-41-00-861-801-A). Energize the Aircraft Electrical Circuits from the External
Power A
(Ref. 24-41-00-861-801-A- Energize the Aircraft Electrical Circuits from the APU
01). (APU Started with APU BAT)
(Ref. 24-41-00-861-801-A- Energize the Aircraft Electrical Circuits from the External
03). Power A and B
(Ref. 24-41-00-861-801-A- Energize the Aircraft Electrical Circuits from the APU
04). (APU started with External power A)
(Ref. 24-41-00-861-801-A- Energize the Aircraft Electrical Circuits from the External
05). Power B
(Ref. 24-41-00-862-801-A). De-energize the Aircraft Electrical Circuits from the
External Power A
(Ref. 24-41-00-862-801-A- De-energize the Aircraft Electrical Circuits from the APU
01).
(Ref. 24-41-00-862-801-A- De-energize the Aircraft Electrical Circuits from the
03). External Power A and B
(Ref. 24-41-00-862-801-A- De-energize the Aircraft Electrical Circuits from the
04). External Power B
(Ref. 31-60-00-860-801-A). EIS Start Procedure
(Ref. 31-60-00-860-802-A). EIS Stop Procedure
JCP Title: C-CHECK CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 1 of 3
JCP Ref: C-CHECK DATABASE REV DATE: Apr 01/2017
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Apr 06/2017 09:22
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE
JOB CARD MPD-TASK: 212600-04
JAI - A330 AMM TASK : 21-26-00-710-808-A
21-26-00 PB 501
TITLE:
A/C Reg.: 21-26-00-710-808-A - Operational
VT-JWR Check of the Cooling Effect Detector
MECH. INSP.
3. Job Set-up
Subtask 21-26-00-865-064-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANEL DESIGNATION FIN LOCATION
715VU L RECIRC FAN 1HG1 B54
** ON A/C 201-300
718VU R RECIRC FAN 1HG2 A60
** ON A/C ALL
721VU AVNCS EXTRACT FAN 1HQ J02
721VU AEVC 4HQ L05
721VU AVNCS VENT CED 6HQ T07
722VU CARGO VENT CTL L1 2HN U43
742VU AVNCS VENT CTL 8HQ A65
742VU CARGO VENT CTL L2 1HN L72
Subtask 21-26-00-860-068-A
B. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-801) .
(2) On the VENTILATION section of the panel 212VU:
· make sure that the EXTRACT pushbutton switch is pushed (AUTO) (the FAULT
and OVRD legends are off)
· make sure that the CAB FANS pushbutton switch is pushed (the OFF legend is
off).
(3) Do the EIS start procedure (EWD DU only) (Ref. AMM TASK 31-60-00-860-801) .
WARNING: MAKE SURE THAT THERE ARE NO PERSONS IN A RADIUS OF 5 M MIN.
AROUND THE NOSE LANDING GEAR. WHEN THE MECHANIC CALL HORN
OPERATES, THE SOUND LEVEL IS MORE THAN 110 DB.
4. Procedure
Subtask 21-26-00-710-066-B
A. Operational Test of the Cooling Effect Detector
ACTION RESULT
1.On the VENTILATION section of the On the VENTILATION section of the panel
panel 212VU: 212VU:
· release the CAB FANS pushbutton · the OFF legend of the CAB FANS
switch. pushbutton switch comes on.
The recirculation fans stop.
On the EWD, after approximately 1
minute:
JCP Title: C-CHECK CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 2 of 3
JCP Ref: C-CHECK DATABASE REV DATE: Apr 01/2017
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Apr 06/2017 09:22
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE
JOB CARD MPD-TASK: 212600-04
JAI - A330 AMM TASK : 21-26-00-710-808-A
21-26-00 PB 501
TITLE:
A/C Reg.: 21-26-00-710-808-A - Operational
VT-JWR Check of the Cooling Effect Detector
MECH. INSP.
ACTION RESULT
· the VENT BLOWING FAULT warning
comes into view.
Then the MASTER CAUT light comes
on and you can hear the single chime.
Then after approximately 5 minutes,
the mechanic call horn in the nose
gear well operates.
2.On the VENTILATION section of the On the VENTILATION section of the panel
panel 212VU: 212VU:
· push the CAB FANS pushbutton switch. · the OFF legend of the CAB FANS
pushbutton switch goes off.
The recirculation fans operate.
On the EWD, after a time delay
between 25 seconds and 180
seconds approximately:
· the VENT BLOWING FAULT warning
goes out of view.
At the same time, the mechanic call
horn in the nose gear well stops.
NOTE: You can stop the mechanic call
horn in the nose gear well if you
push the RESET pushbutton
switch on the panel 925VU.
5. Close-up
Subtask 21-26-00-860-069-A
A. Put the aircraft back to its initial configuration.
(1) Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-802) .
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-801) .
*** END OF CARD ***
JCP Title: C-CHECK CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 3 of 3
JCP Ref: C-CHECK DATABASE REV DATE: Apr 01/2017
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Apr 06/2017 09:22
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE