0% found this document useful (0 votes)
78 views2 pages

Ps m144 (HCBF) Bifacial 525 545w

The PS-M144(HCBF)-xxxW is a bifacial mono-crystalline solar module with power outputs ranging from 525 to 545 Watts, featuring advanced production techniques and high cell efficiency up to 23%. It is designed for various applications including residential, commercial, and off-grid systems, with certifications for quality and safety. The module comes with a 12-year product warranty and a 25-year linear power warranty, ensuring durability and performance under diverse weather conditions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
78 views2 pages

Ps m144 (HCBF) Bifacial 525 545w

The PS-M144(HCBF)-xxxW is a bifacial mono-crystalline solar module with power outputs ranging from 525 to 545 Watts, featuring advanced production techniques and high cell efficiency up to 23%. It is designed for various applications including residential, commercial, and off-grid systems, with certifications for quality and safety. The module comes with a 12-year product warranty and a 25-year linear power warranty, ensuring durability and performance under diverse weather conditions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

PS-M144(HCBF)-xxxW

Half-Cell MBB Bifacial Module

525 -545 Watt (182mm Cell Size)

Philadelphia Solar’s
Mono-Crystalline modules FEATURES
with power up to 545 Wp are
produced using the
state-of-the-art (automated)
robotic production lines. Lower microcrack problem loss
Module’s Cell Efficiency up to 23%
�ese modules are suitable to comparing with 5-busbar module
be used for most electrical
power applications and have
excellent durability to
prevailing weather conditions Lower internal resistance loss Lower degradation PERC technology

CERTIFICATIONS
Less partial shading current mismatch Better temperature coefficients come
IEC 61215 / IEC 61730 loss so more power output. from half-cell design.
EN ISO 9001: 2015
Quality Management System
EN ISO 14001: 2015
Environmental Management
System
ENJ ISO 45001: 2018
LINEAR PERFORMANCE WARRANTY
Occupational health and safety
management systems %100
% 97.5 12 Year Product Warranty
12 years - 92.0 %
25 years - 85.5 %
%92.0
25 Year Linear Power Warranty

APPLICATIONS Only -0.5% Annual Degradation

%85.5

1 12 25
End of Year
On-Grid Residential
Roof-Tops
I-V CURVES

16
1000W/m²
On-Grid Commercial/ 14
Current(A)

Industrial Roof-Tops
12 800W/m²
Normalizedlsc,Voc,Pmax %

10
600W/m²

Off-Grid Systems
(Including Lighting Systems)

Cell Temperature(℃)

Solar Power Plants

QP-04-CAD/Rev.2
ELECTRICAL CHARACTERISTICS

POWER AT STC 525 W 530 W 535 W 540 W 545 W

Short Circuit Current - Isc (A) 13.64 13.71 13.79 13.87 13.94

Maximum Power Current - Impp (A) 12.93 13.02 13.11 13.20 13.27

Open Circuit Voltage - Voc (V) 49.27 49.35 49.42 49.49 49.65

Maximum Power Voltage - Vmpp (V) 40.61 40.71 40.81 40.91 41.07

Module E�ciency - η’ (%) 20.36% 20.55% 20.75% 20.94% 21.13%

Values at Standard Test Conditions STC (Air Mass AM 1.5 , Irradiance 1000 W/m2 , Cell Temperature 25o C).

MATERIAL CHARACTERISTICS Module Drawings

Characteristics Value

Cells per Module 144 (72 x 2)

Cell Type Grade A - Mono PERC Crystalline Silicon

Front Surface Anti-Reflective Coated Tempered 3.2 mm Glass

Encapsulant PID Free EVA

2285±1
Back Cover Transparent Backsheet

Frame Anodized Aluminum

Junction Box IP68 , 3 Bypass Diodes

Cable Length 325 mm Cables Length (Can be Customized)

Fire Classification Type I

1134±1 35±1
THERMAL CHARACTERISTICS PHYSICAL CHARACTERISTICS

Characteristics Value Characteristics Value


A A
Open Voltage Temperature
-0.22 Module Dimensions (mm) 2285±1 x 1134±1 x 35±1
Coe�cient VOC (%/C°)
Short Circut Current Temperature
Coe�cient ISC (%/C°)
+0.05 Module Weight (kg) 29 ± 3%
1400
800

Power Temperature
-0.35 Packaging Value
Coe�cient PMP (%/C°)

NOCT (°C) 45±2 Modules per Pallet 31

OPERATING CONDITIONS 40 Feet High-Cube Container 620 Modules

Maximum Sytem Voltage - Vmax (V) 1500 Mechanical Load Value 1084

Maximum Series Fuse (A) 25 Max Static load (Front) 5400 Pa


Cross Section A-A
IEC: -40 to +85 Max Static load (Back) 2400 Pa
Operating Temperature Range (°C)
UL: -40 to +90

Power measuring tolerance: ± 3%, other measurements tolerances: ± 5%.


35

Datasheet is subjected to change without prior notice, always obtain the most recent version of the
datasheet.
Caution: For professional use only, the installation and handling of PV modules and cleaning modules
require professional skills and should only be performed by qualified professionals, please read the
Installation and Operation Manual before using the modules, also Cleaning Guidelines 35