Online UPS (V2) Shopping Cart
NOTIFICATIONS
HomeElectronicsElectrical equipment and components and suppliespower conditioning equipmentOnline UPS (V2) (Q2 Category)
APC Online UPS of Rating 6.0 KVA With Battery
Of Backup Time 60 Minutes
APCR
(SRV6KL-INX)
₹ 178,500.00 38% OFF
Trends Purchase History
Product Details
Price For : 1 pieces
MRP/Unit: ₹ 286,580.00
Offer Price/Unit: ₹ 178,500.00
Availability: 10 In Stock
Min. Qty. Per Consignee: 1 EDIT CONSIGNEE
Product id: 5116877-10497765889
Country Of Origin: India
Local Content (MII): 51%
Certification:
Seller Details
Sold by: Resellers
OEM verified Reseller
OEM verified catalogue
Seller Excellence 3.5 - 3.99
Seller Details VIEW ALL SELLERS
ADD TO CART REPORT THIS PRODUCT
Ask GeMmy
Product Compare Product History 1
Specifications
Rating in KVA 6.0 KVA
Switching Technology IGBT-PWM
Input Voltage AC Single phase 160V - 260V
50Hz
Output Voltage AC Single phase 230V +/-1% 50
Hz
Warranty for UPS (Years) 2
Battery/Backup Bank Provided With Battery
with Online UPS ( Hint: In case the
UPS is supplied with battery, seller
shall ensure compliance to the GST
Rates as per recommendations
made in the 45th Meeting of GST
council dated 17th Sep 2021 )
Type of Battery (hint: NA in case SMF-VRLA conforming to
Battery not provided) JISC:8702(Pt.I,II&III), Stationary
Lead Acid Batteries (with tubular
positive plates) in monobloc
container conforming to
IS:13369:1992 latest
Backup time (Minutes) (hint: NA in 60 Minutes
case battery not provided)
Warranty for battery (Years) by 2
Battery Manufucaturer/Brand hint:
NA in case battery not provided
Inbuilt isolation transformer Without
Overall Efficiency (%) >/=94% without Inbuilt isolation
transformer
Overload limit 20% Overload for minimum 10
minute
Accessories Cabling 6 meters ( input upto 3m
and output upto 3m) ,NA
Type of Design / Construction Floor Standing
VIEW LESS
Special Terms & Conditions
In addition to General Terms and Conditions of GeM, the following Special T&C shall be applicable for Online UPS ( Version 2.0) with reference to Installation
and Commissioning.
Seller's Responsibility: Installation and Commissioning shall involve all the interconnections, any cabling between power source, switch boards within 3
metre range for input power and connecting Output power in the Scope of seller.
Buyer's Responsibility: Buyer will ensure well ventilated/covered site/room having requisite power points/distribution board to provide input power to UPS
as well as to take out power from UPS within 3 metre of the location of UPS placement.
The above is not applicable for the stores supplied without installation and commisioning.
Note: The above is indicative and any incidental requirement related to above responsibilities shall also be considered in the responsibilities of Buyer/Seller
as applicable.
Ask GeMmy
Product Compare Product History 1
Generic
Rating in KVA 6.0 KVA
Switching Technology IGBT-PWM
Input Voltage AC Single phase 160V - 260V 50Hz
Output Voltage AC Single phase 230V +/-1% 50 Hz
Warranty for UPS (Years) 2
Battery/Backup Bank
Battery/Backup Bank Provided with Online UPS ( Hint: In case the UPS is With Battery
supplied with battery, seller shall ensure compliance to the GST Rates as
per recommendations made in the 45th Meeting of GST council dated 17th
Sep 2021 )
Type of Battery (hint: NA in case Battery not provided) SMF-VRLA conforming to JISC:8702(Pt.I,II&III), Stationary Lead Acid
Batteries (with tubular positive plates) in monobloc container
conforming to IS:13369:1992 latest
Backup time (Minutes) (hint: NA in case battery not provided) 60 Minutes
Battery Make Quanta
Battery Model Number 12V42AH
Battery capacity (Ah) 42
Weight of the Battery (kg) 14
Number of Batteries 20
Minimum Guaranteed VAH 1600 X Per KVA X Per hour of backup time
Warranty for battery (Years) by Battery Manufucaturer/Brand hint: NA in 2
case battery not provided
Accessories with Battery NA
Installation and Commissioning or Service
Installation and Commissioning ( Covered in the Scope of Supply) Provided
After sales service ( Turn Around Time) Within 24 hours,Within 48 hours,Within 7 days,NA
Preventive Maintenance ( Hint: Mention Timeline if provided, NA if not NA
provided)
Other Services provided PAN India service support on 24 x 7 basis,AMC support available
warranty,NA
Ask GeMmy
Product Compare Product History 1
Performance / Functional
Inbuilt isolation transformer Without
Overall Efficiency (%) >/=94% without Inbuilt isolation transformer
Power Factor Load Supported 0.8 or better
Overload limit 20% Overload for minimum 10 minute
Total Harmonic Distortion(THD) (%) 3% Maximum @ 100% Linear Load
Other Functional Features Crest factor on full non-linear load is not less than 3:1,Noise level (1
meter distance from UPS) should be less than 70dB,Input power factor
at full output load leading to unity with active power factor correction
(APFC) >/=0.92,Transient response time (for 100% load change,output
must remain within +/-1% and recovery) as <20 milliseconds,Battery
recharge time (after complete discharge to 90% charge) and charge
rating: Battery recharge time to 90% charge after 100% DoD : 8 to 10
Hours,Maximum overshoot and Under shoot of output rated voltage (in
percentage) (4%),Voltage Regulation from no load to full load (%) (< / =
2%),UPS input power factor better than 0.95 (at rated voltage)
Accessories
Accessories Cabling 6 meters ( input upto 3m and output upto 3m),NA
Salient Features
Protection Protection for under voltage at battery terminal,Protection of Over
voltage,Short Circuit & over load at UPS output terminal,Over
temperature protection
Metering Input Voltage,Output Voltage,Input Current,Output Current,Input
Frequency,Output Frequency,Input Power,Output Power,Input Power
Factor,Output Power Factor,Battery Voltage and Current
Alarms and Indications Indicator for Mains presence,Indicator for Battery charging and
discharging,Indicator for Output Over Load with Audible Alarm,Indicator
for Low Battery Voltage with Audible Alarm,Alarm for Over
temperature,Alarm for Low Battery
Additional Features Pure Sinewave AC Output,NA
Ask GeMmy
Product Compare Product History 1
Design / Construction
Type of Design / Construction Floor Standing
Form factor of UPS NA (for Floor Standing)
Enclosure (mm) 1.2 mm Minimum Thickness of M.S. Sheet duly powder coated
Degree of Protection IP20
DC Bus Voltage (In Volts) 240
Other Constructional Features Static by pass facility,Shall be complete with rack rail kit for mounting of
UPS in the rack and shall be housed in rugged enclosure made of steel
sheet having 1.2 mm (minimum) thickness, aesthetically finished,duly
pretreated and powder coated,UPS shall be free from workmanship
defects, sharp edges, nicks, scratches, burst, etc. All fasteners shall be
fixed properly. The equipment shall be complete with all parts and all
parts shall be functional,NA
Operating Conditions
Minimum Operating Temperature 0 degree Celsius
Maximum Operating Temperature 40 degree Celsius
Relative Humidity Non Condensing at 40 deg C 95 percent
Buyer Specific Requirement
Environmental Test Report Requirements Damp Heat Test : in accordance with IS:9000(part 5/sec.2)1981 at
Temperature of 40 degree C,two cycles of (12+12) hours each 2007),Dry
Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed
2007) at 55 degree C for 16 hrs,Cold Test : in accordance with IS:9000
(Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs,NA
Battery Test Report NA
Intended Applications Critical Infrastructure,Network IT Equipment,Medical
Equipment,Support for Data Centers, Network operating centers,
Security operation centers, State and District centers, Command and
Control center etc., across the Country to provide impetus to the e-
Governance services e.g. Public food distribution, e Way bill, Counseling,
e-Office, IVFRT etc., services under Digital India Programme,NA
Other Requirements ROHS compliance,KW rating shall be 0.8 time of KVA rating
Reports And Certification
Type of lab which carried out Test of Complete Product to prove the NABL accredited lab
conformity of product as per specification
Agree to provide all relevant documents Test Reports/supporting document Yes
/reports etc to the buyer at the time of bidding or on demand
As per Meity (Government of India) guidelines UPS shall have valid BIS CRS Yes (For UPS rating upto 10KVA)
certifications as applicable
Ask GeMmy
Product Compare Product History 1
WEB INFO ABOUT GeM
Terms of Use Introduction to GeM
Website Policies Statistics
Document Help Right to Information
Sitemap Analytics
Web Information Manager New on GeM
BRAND GeM
NEWS & EVENTS RESOURCES
Newsroom GeM Handbook
Gallery OM’s/Circulars
Notifications Terms and Conditions
CCM Schedule Policies/Manuals
Forums Miscellaneous
TESTIMONIALS MOU'S
TRAINING NEED HELP ?
LMS FAQs
Training Calendar Feedback
Training Module Raise a Ticket
Facilitators Contact Us
Download GeM Logo Careers
© 2021 GeM All rights reserved Site operated and maintained by Managed Service Provider
Ask GeMmy
Product Compare Product History 1