1. A VxRail administrator wants to rename the VxRail cluster and the VxRail vSAN datastore.
What is the recommended method to make these changes?
A. Refer to the VMvvare vSphere and vSAN documentation Follow the steps detailed in the
VMware documentation
B. Renaming the objects is not permitted Rebuild the cluster with the desired names
C. Use SolVe to generate the relevant procedures Follow the steps detailed in the procedures
D. Refer to the VxRail Appliance Administration Guide Follow the steps detailed in the guide
Answer: B
6. While creating a new VM on a vSAN datastore, an administrator did not assign a storage
policy.
What is the result?
A. VM will be created with the vSAN Default Storage Policy
B. VM will be created with FTT=0
C. VM will be created with RAID-1 (FTT=2)
D. VM will be created with Force Provisioning only
Answer: A
9. What is the maximum number of disk groups supported by a VxRail P Series node?
A. 2
B. 3
C. 4
D. 5
Answer: C
11. What is the maximum number of nodes supported in a VxRail cluster with 1 GbE
networking?
A. 12
B. 8
C. 4
D. 16
Answer: B
12. VxRail Manager provides a software stack for a software-defined data center.
Which layers are part of the stack?
A. Storage, security, and management
B. Security, management, and network
C. Network, storage, and security
D. Management, network, and storage
Answer: D
13. An administrator is trying to monitor vSAN backend IOPS, throughput, and latency in the
vSphere Client.
What must be turned on to monitor these metrics?
A. vSAN Disk Management
B. vSAN Performance Service
C. vSphere Distributed Resource Scheduler
D. vSAN Health Service
Answer: B
14. A company is planning to deploy VxRail and implement big data analytics solution with
these requirements:
- Supports both all-flash and all NVMe nodes
- Supports in-memory intensive database applications
- Configurable with 4 Intel Xeon scalable processor
Which VxRail model is recommended based on the deployment requirements?
A. S Series
B. G Series
C. D Series
D. P Series
Answer: D
17. The VxRail administrator has been given the task of migrating the current production
environment to a VxRail cluster with external block storage. The VMs must remain online during
the migration.
Which VMware feature can be used?
A. Storage vMotion
B. vMotion
C. VMware Converter Software
D. High Availability
Answer: A
18. A customer has a large storage capacity and low I/O performance requirements.
Which VxRail solution is the best fit?
A. E Series
B. P Series
C. S Series
D. V Series
Answer: C
19. There is a request to add new disks to an existing VM residing on a VxRail vSAN that you
manage. One disk is 250 GB. The VM is using the vSAN default storage policy.
How many vSAN objects will be created?
A. 2
B. 3
C. 6
D. 9
Answer: D
20. Configure the new VDS - Add hosts, assign physical adapters, and assign port groups to
VMkernel adapters.
21. An environment has two VxRail Clusters with the following configuration
• Cluster-A is using FTT = 2 and FTM = Erasure Coding
• Cluster-B is using FTT = 2 and FTM = Mirroring
A 100 GB VM is planned to be vMotioned from Cluster-A to Cluster-B.
How much more vSAN capacity is consumed in Cluster-B than in Cluster-A?
A. 100 GB
B. 167 GB
C. 150 GB
D.0GB
Answer: B
Explanation:
To calculate the additional vSAN capacity consumed when a 100 GB VM is vMotioned from
Cluster-A to Cluster-B, consider the following:
Cluster-A: FTT = 2 and FTM = Erasure Coding (RAID 6), which uses approximately 1.5 times
the data size, thus 100 GB VM uses about 150 GB of vSAN capacity.
Cluster-B: FTT = 2 and FTM = Mirroring (RAID 1), which uses 3 times the data size, thus 100
GB VM uses 300 GB of vSAN capacity.
The difference in vSAN capacity consumed between Cluster-B and Cluster-A is: 300 GB
(Cluster-B) - 150 GB (Cluster-A) = 150 GB
So, Cluster-B consumes 150 GB more vSAN capacity than Cluster-A.
Reference: VMware vSAN Storage Policies: vSAN Storage Policies
22. An application consisting of two VMs must be keep on two separate hosts.
Which VMware feature would enable this?
A. Storage vMotion
B. Fault Tolerance
C. High Availability
D. Distributed Resource Scheduler
Answer: C
23. Configure the new VDS - Add hosts, assign physical adapters, and assign port groups to
VMkernel adapters.
24. How is dynamic resource scheduling achieved in a VxRail environment?
A. By setting static resource limits
B. Through automated load balancing
C. Via manual allocation during setup
D. Using third-party scheduling tools
Answer: B
26. What is a consideration when planning for node expansion of an existing 4-node All-Flash
Dell EMC VxRail 4.5.2xx cluster?
A. vSphere Web Client is used to perform the expansion procedure
B. New nodes can be hybrid or All-Flash
C. New nodes must be identical to the existing nodes
D. Expansion procedure is performed by Dell EMC or a Dell EMC partner
Answer: D
27. A VxRail administrator using the vSphere Client wants to manage the iDRAC configuration
of a node.
Which path should be followed?
A. Host > Configure > VxRail
B. Host > Monitor > VxRail
C. Cluster > Monitor > VxRail
D. Cluster > Configure > VxRail
Answer: A
28. What is a benefit of using a trusted third party or an organization CA in VxRail Manager?
A. Allows decrypted communication over trusted secured networks
B. Minimal client configuration for trust relationships
C. Secured trust relationship between internal and external servers
D. Eables secure digital trust network verification over unsecured networks
Answer: B
29. As a VxRail administrator you have been asked to configure vSAN fault domains After
selecting the VxRail cluster, where would you navigate to in vCenter to accomplish this task?
A. Configure > vSAN > Disk Management > Fault Domains & Stretched Cluster
B. Configure > vSAN > General > Fault Domains & Stretched Cluster
C. Configure > vSAN > Fault Domains & Stretched Cluster
D. Configure > vSAN > Configuration Assist > Fault Domains & Stretched Cluster
Answer: B
30. An administrator is generating a SolVe procedure to replace a failed disk in a VxRail node.
What is the order of the steps?
A. 1. Select the VxRail version
31. Create a VDS with the required number of uplinks.
B. 1. Configure the new VDS - Add hosts, assign physical adapters, and assign port groups to
VMkernel adapters.
32. An administrator needs to place a node in maintenance mode They want to ensure vSAN
does not start rebuilding absent components during the time it takes for maintenance to be
completed
What would allow the administrator to achieve this?
A. Temporarily disable components ^synchronization.
B. Temporarily set FTT=0 in vSAN Storage Policy.
C. Increase vSAN Object repair timer
D. Increase durability component lifetime.
Answer: C
Explanation:
To ensure that vSAN does not start rebuilding absent components while a node is in
maintenance mode, an administrator should increase the vSAN Object repair timer. The Object
repair timer controls the delay before vSAN initiates the rebuild of absent components. By
increasing this timer, the administrator can ensure that maintenance can be completed without
triggering unnecessary rebuilds, reducing the load on the system and preventing potential data
redundancy issues.
Reference: VMware vSAN Configuration Guide: vSAN Configuration Guide
34. What is the order of steps to generate the SolVe procedure to add a capacity drive to a
VxRail node?
Answer:
35. What is a supported VxRail deployment?
A. External vCenter Server with internal DNS
B. External vCenter Server with customer-supplied Virtual Distributed Switch
C. Internal vCenter Server with customer-supplied Virtual Distributed Switch
D. Internal vCenter Server with hosts file
Answer: B
36. What primary role does the VxRail Manager Certificate play in a VxRail environment?
A. It manages the encryption of stored data.
B. It authenticates and secures communications between cluster nodes.
C. It schedules regular system audits and compliance checks.
D. It provides a user interface for system configuration.
Answer: B
37. A VxRail administrator has been tasked with configuring static LAG for a VxRail cluster
vSAN traffic. The ToR switches have already been configured.
Which VDS port group load balancing option should be configured?
A. Route based on physical NIC load
B. Route based on originating virtual port
C. Route based on IP hash
D. Route based on source MAC hash
Answer: C
39. A company has deployed VxRail independent of an existing VMware environment. VxRail
hosts and VMs are configured into the organization's DNS server host records. The VxRail
deployed VDS is being used.
Which VxRail deployment model has been implemented by the company?
A. External vCenter with internal DNS
B. Internal vCenter with internal DNS
C. Internal vCenter with external DNS
D. External vCenter with external DNS
Answer: C
40. What are the vSAN storage policy settings applied to the VxRail Manager VM during initial
setup?
A. Primary level of failures to tolerate = 1 Failure tolerance method = Erasure coding Object
space reservation (%) = 100
B. Primary level of failures to tolerate = 1 Object space reservation (%) = 100
C. Primary level of failures to tolerate = 1 Failure tolerance method = Mirroring Object space
reservation (%) = 50
D. Primary level of failures to tolerate = 2 Failure tolerance method = Mirroring
Answer: B
41. What is the fault tolerance method provided by the default storage policy on a newly
deployed VxRail all-flash cluster?
A. RAID-5
B. RAID-1
C. RAID-6
D. RAID-1/10
Answer: B
45. An administrator wants to locate the PSNT for a specific VxRail node in order to contact
support. Where in the vSphere Client can this information be located?
A. Hosts and Clusters > Host > Configure > Advanced System Settings
B. Hosts and Clusters > Host > Monitor > VxRail > Physical View
C. Menu > VxRail
D. Menu > Administration
Answer: B
46. SIMULATION
VxRail administrator got the following warning while on node physical view.
"Health monitoring is currently disabled and information may not be accurate.
Dell recommends that health monitoring is enabled."
Use the simulator to enable the relevant service and resolve the issue.
Answer:
To resolve the issue of health monitoring being disabled and enable the relevant service, follow
these steps:
Log in to vSphere Client:
Open the vSphere Client.
Enter the username: [email protected].
Enter the password: VMw@r3!123.
Click Login.
Navigate to VxRail Manager:
In the vSphere Client interface, expand VxRail-DC and then VxRail-Cluster.
Select VxRail Manager.
Access VxRail Health Monitoring Settings:
Click on the Configure tab.
Under VxRail, select Health.
Enable Health Monitoring:
Find the option for Health Monitoring.
If it is disabled, click Edit or the relevant button to enable it.
Ensure that Enable Health Monitoring is checked.
Click Apply or OK to save the changes.
Verify Health Monitoring Status:
Go back to the Summary tab or the appropriate section in VxRail Manager.
Verify that the health monitoring status is now enabled and shows as healthy.
Steps using the Simulator:
Login to vSphere Client:
Open the simulator and navigate to the vSphere Client interface.
Log in using the credentials:
Username: [email protected].
Password: VMw@r3!123.
Navigate to VxRail Manager:
In the vSphere Client interface, expand VxRail-DC and then VxRail-Cluster.
Select VxRail Manager.
Enable Health Monitoring:
Click on the Configure tab.
Under VxRail, select Health.
Click Edit to modify the health settings.
Check the box for Enable Health Monitoring.
Click Apply or OK to save the changes.
Verify:
Go back to the Summary tab in VxRail Manager.
Ensure that the warning message about health monitoring being disabled is no longer present
and that health monitoring is active.
Reference: Dell VxRail Administration Guide: VxRail Administration Guide
By enabling health monitoring in VxRail Manager, you ensure that the system can accurately
monitor and report the health status of the nodes, helping to maintain system stability and
performance.
47. A user has three G Series nodes in a VxRail cluster. They are planning to add five additional
G Series nodes.
How much additional rack is required to accommodate the new nodes?
A. 1U
B. 2U
C. 5U
D. 10U
Answer: B
49. What is the block size and object level of the vSAN deduplication algorithm?
A. 8 KB per datastore
B. 4 KB per disk group
C. 4 KB per datastore
D. 8 KB per disk group
Answer: B